You are on page 1of 1

PERHITUNGAN LOAD SHARE TERHADAP PERKIRAAN BEBAN 

Pemiilhan MCB 
MCB Utama size Lampu Lampu Lampu Lampu Lampu Lampu
Grouping MCB

Perhitungan 

Perhitungan 
Lemari  Rice  Microwave  Mesin  Water 

Watt beban
Amp beban
Downlight  Taman  Baret  Gantung  Dinding  TL  TV Setrika Pompa Air AC
Es Cooker Oven Cuci heater

size 
Item 10 Watt 20 Watt 22 Watt 3x10 Watt 10 Watt 20 Watt Kerangan

10 20 22 30 10 20 100 80 100 1000 150 100 125 500 500


Lemari Es (100W), TV(80W), Rice Cooker (100W), 
1 6 1.9 GPO (90% Utilisasi) 324 1 2 1
microwave(1000W)
Mesin Cuci (150W), Setrika (100W), pompa air (125W), 
2 10 5.4 GPO (50% Utilisasi) 937.5 1 1 1 1 1
Water heater (500W)

3 16 6 4.6 AC Bedroom (80 % Utilisasi) 800 2 Air Conditioning (1/2 Pk atau < 500 W)

4 4 0.8 Penerangan (60 % Utilisasi) 132 1 2 5 2 2 Penerangan bagian depan


5 4 0.9 Penerangan (60 % Utilisasi) 154.8 5 1 4 1 1 3 Penerangan bagian belakang
6 4 0.0 Spare 0
7 4 0.0 Spare 0
Total 10.7 2348.3 6 3 9 1 3 5 1 2 1 1 1 1 1 1 2