You are on page 1of 4

STRUCTURAL DESIGN PAGE :

DOC#: PGB/OGP-CA-A28-20B2-03

ESTIMATE PILE CAPACITIES


(Using SPT value from borehole results)
METER STATION
Type of pile : 150 x 150mm reinforced concrete pile
pilecap

Ultimate Pile Capacity = End bearing + Skin friction fill


Qult = Qb + Qs
150x150 R.C PILE
Skin Friction, Qs = fs . As .L

End Bearing, Qb = fb . Ab

Unit skin friction fs = N in ton / m^2 =< f1 = 10 ton/m^2


3 or 5 ( sand or clay)

Unit base resistance fb = 0.4 x N x D in ton /m^2 =< q1 = 40N for sand
B = 30N for silt fs
where : = 10N for clay
N = avg. SPT value from borelogs
B = width or diameter of pile = 0.15 m
L or D = depth of pile penetration into soil layer
Ab = area of base pile = 0.023 m^2
As = surface area of embed. length = 0.600 m^2
fb
fn = unit negative skin friction = 0.8 ton/m^2
Negative skin friction = fn x As x L
e.g Avg N = N1+N2+N3+…
n
MAX. STRUCTURAL CAPACITY OF PILE : 0.25*fcu*A= 168.75 kN
TAKE WORKING LOAD OF PILE : 26 ton or 260 kN

Depth Length Avg N fb fs Qb Qs Qult


(m) (m) (ton/m^2) (ton/m^2) ( ton ) ( ton ) ( ton )
0.0 - 0.3 0.30 0 0 0.00 0.00 0.00 0.00

1.5 - 1.95 0.45 0 0 0.00 0.00 0.00 0.00

3.0 - 3.45 0.45 0 0 0.00 0.00 0.00 0.00

3.5 - 4.0 0.50 0 0 0.00 0.00 0.00 0.00

4.5 - 4.95 0.45 0 0 0.00 0.00 0.00 0.00

6.0 - 6.45 0.45 0 0 0.00 0.00 0.00 0.00

6.5 - 7.0 0.50 0 0 0.00 0.00 0.00 0.00

7.5 - 7.95 0.45 0 0 0.00 0.00 0.00 0.00

9.0 - 9.45 0.45 0 0 0.00 0.00 0.00 0.00

10.5 - 10.95 0.45 0 0 0.00 0.00 0.00 0.00

12.0 - 12.45 0.45 0 0 0.00 0.00 0.00 0.00


STRUCTURAL DESIGN PAGE :
DOC#: PGB/OGP-CA-A28-20B2-03

13.5 - 13.95 0.45 0 0 0.00 0.00 0.00 0.00

15.0 - 15.45 0.45 1 1 0.20 0.03 0.05 0.08

16.5 - 16.95 0.45 1 1 0.20 0.03 0.05 0.08

18.0 - 18.45 0.45 2 2 0.40 0.05 0.11 0.16

19.5 - 19.95 0.45 2 2 0.40 0.05 0.11 0.16

21.0 - 21.45 0.45 2 2 0.40 0.05 0.11 0.16

22.5 - 22.95 0.45 2 2 0.40 0.05 0.11 0.16

24.0 - 24.45 0.45 2 2 0.40 0.05 0.11 0.16

25.5 - 25.95 0.45 1 1 0.20 0.03 0.05 0.08

27.0 - 27.45 0.45 3 4 0.60 0.08 0.16 0.24

28.5 - 28.95 0.45 3 4 0.60 0.08 0.16 0.24

30.0 - 30.45 0.45 4 5 0.80 0.11 0.22 0.32

31.5 - 31.95 0.45 3 4 0.60 0.08 0.16 0.24

33.0 - 33.45 0.45 4 5 0.80 0.11 0.22 0.32

34.5 - 34.95 0.45 3 4 0.60 0.08 0.16 0.24

36.0 -36.45 0.45 3 4 0.60 0.08 0.16 0.24

37.5 - 37.95 0.45 4 5 0.80 0.11 0.22 0.32

39.0 - 39.45 0.45 5 6 1.00 0.14 0.27 0.41

40.5 - 40.95 0.45 5 6 1.00 0.14 0.27 0.41

TOTAL = 1.35 2.70 4.05

Take depth of pile = 40.5 m ( From existing ground level)

Ultimate Pile Capacity, Qult = 4.05 ton < 65 ton i.e 2.5 * Qstr. O.K

Allowable Load = Qult = 1.62 ton


F.S

For backfill platform,


Height of fill = 1.7 m
Pile Bearing Capacity = Allow. Load - neg. skin friction
= Qult - fn x As x L
STRUCTURAL DESIGN PAGE :
DOC#: PGB/OGP-CA-A28-20B2-03
2.5
= 0.828 ton
= 8.28 kN

Therefore,
Total pile length required = 42 m
STRUCTURAL DESIGN PAGE :
DOC#: PGB/OGP-CA-A28-20B2-03

pilecap

You might also like