You are on page 1of 64

Product Catalogue 2004

Safety Relays
UE 10 – UE 48 Series
UE 10 - UE 48 Safety Relays

Selection Table

Main Application Mode Features UE-Unit

Single Channel Input 2


UE 23-2 MF
1

2
1
UE 43-2 MF

Stop Cat. 3
0 1
UE 43-3 MF

Dual Channel Input 6


UE 43-6 MF
4

3 UE 45-3 S1 2 3
0 1 Output
up to 3 s Off-Delay
Stop Cat.
1

3 UE 45-3 S1 2 30
1 Output
0 up to 30 s Off-Delay

3 UE 44-3 SL 2 3
1 Output
1) Dual Channel Input 0 up to 3 s On-Delay
Stop Cat.
0
3 UE 44-3 SL 2 30
1 Output
0 up to 30 s On-Delay

Dual Channel Input 2


Stop Cat.
0 1 UE 42-2 HD

Dual Channel Input 3


Stop Cat.
0 1
UE 10-3 OS

2
1 UE 48-2 OS
Dual Channel Input
Stop Cat.
0
3
UE 48-3 0S
0

Expansion unit 4
2 UE 10-4 XT

4 UE 11-4 DX
Off-Delay
2 0.5, 1, 2, 3 s

1 ) Safety switch with mechanical locking

2 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03
UE 10 - UE 48 Safety Relays

Contents

Dimensional drawings ............................................................ 4

Technical Notes ........................................................................ 6

UE 10-3 OS
Safety Relay for opto-electronic
protection systems ............................................................................ 7

UE 10-4 XT und UE 11-4 DX


Expansion Modules
(UE 10 without Delay, UE 11 with Off-Delay) ................ 11

UE 23-2 MF
Safety Relay for Emergency Stop and
Safety Switch applications ........................................................ 15

UE 42-2 HD
Safety Relay for two-hand operation ................................. 19

UE 43-2 MF
Safety Relay for Emergency Stop and
Safety Switch applications ........................................................ 23

UE 43-3 MF
Safety Relay for Emergency Stop and
Safety Switch applications ........................................................ 27

UE 43-6 MF
Safety Relay for Emergency Stop and
Safety Switch applications ........................................................ 31

UE 44-3 SL
Safety Relay with On-Delay option for
Emergency Stop and Safety Switch applications ........ 35

UE 45-3 S1
Safety Relay with Off-Delay option for
Emergency Stop and Interlock applications .............. 39

UE 48-2 OS und UE 48-3 OS


Safety Relay for Emergency Stop, Safety Switch,
Safety Mats and ESPE applications .................................... 43

C US C US Operating data ........................................................................ 47

Glossary ..................................................................................... 48

Safety Navigator .................................................................... 49

Sample Wiring Diagrams .................................................... 50

8 009 607/18-09-03 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 3
UE 10 - UE 48 Safety Relays

Housing A

82.5
63
107.6

114
93.6
75.3

93.3
96.5
22.5

48.3
66.7

A.1 Housing (screw type terminals)

78
58
107.6

114
93.7

93.3
96.5
22.5

A.2 Housing (removable terminals)


Dimensions in mm

4 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03
UE 10 - UE 48 Safety Relays

Housing B, C and D

93.5
71.5 22.5

For mounting rail EN 50 022

123
96
61.2
52.5
75

3.8
75.5

107
45 120.5
55.5
76.5

B Housing (screw type terminals) D Housing (screw type terminals)

for mounting rail EN 50 022


52.5
75

3.8

107
90 120.5

C Housing (screw type terminals)


Dimensions in mm

8 009 607/18-09-03 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 5
UE 10 - UE 48 Safety Relays

Technical Explanations

Symbols

Function Applications

Off-delay

Safety Switch

On-delay

1 Normally open (NO) Emergency Stop


input

1 Normally closed (NC)


input
Safety Laser Scanner

EDM External device


monitoring

Reset Safety Light Curtain

Automatic Reset

Manual Reset

Safety Mat

Two-hand Controls

Safety Locking Device

6 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03
UE 10-3 OS Series

UE 10-3 OS
Safety Relay <

for opto-electronic protective equipment

Application

The UE 10-3 OS Safety Relay is a relay module for:

 Electro-Sensitive Protective Equipment (ESPE) with monitored


semiconductor outputs, integral external device monitoring (EDM)
and Restart Inhibit, such as
C 4000
C/M 2000
MSL
S 3000
 Safety systems with monitored semiconductor outputs, integral
external device monitoring and Restart Inhibit, such as LSI and
LE 20

Features EN 954-1 Same as protective


device
EN 61 496 Types 2, 3, 4
 Single- or dual-channel control
 NC contact for external device monitoring (EDM)
 Outputs: 3 normally open contacts, 1 normally closed contact
3
 2 LEDs for relays K 1 and K 2
1
 Increase in the number of outputs by way of the expansion units
UE 10-4 XT
UE 11-4 DX
 Available with removable terminals (key coded)
 “A“ Housing (see Page 4), width: 22.5 mm EDM
EDM
within protective
device

See Pages 51 and 52 for sample wiring diagrams

S 3000

or
oder

C 4000

C US

8 009 607/18-09-03 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 7
UE 10-3 OS Series

Function

If the semiconductor outputs of the installed safety


device (e. g. C 4000, S 3000) are energised, then the 13 23 33 B1 Y1 Y2 B3

safety output contacts will close. B1 B2 Y1 41 13 23 33

When at least one of the semiconductor outputs of the


safety device becomes de-energised, then the output CH 1 K1

contacts revert back to open circuit status. K2


CH 2

If Restart Inhibit is needed, then this is achieved in the


safety device, for example C 4000 or S 3000. B3 B4 Y2 42 14 24 34

14 24 34 B2 41 42 B4
External device monitoring (EDM)
Safety Category 3 or 4 requires monitoring of
contactors. This is provided in the connected protective Internal Circuitry UE 10-3 OS
device, for example in the C 4000 or S 3000. The
normally closed contact (Y 1 - Y 2) in the UE 10-3 OS
unit is, however, a part of this contactor monitoring
system.

The UE 10-3 OS 2 unit has screw type terminals.


The UE 10-3 OS 3 unit has removable terminals.

8 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03
UE 10-3 OS Series

Technical Data U E 10-3 OS

min. typ. max.


General System Data
Supply voltage to B 1 - B 2, B 3 - B 4
Electrical output circuit > 25 V AC / 60 V DC PELV
Electrical output circuit < 25 V AC / 60 V DC PELV or SELV

Inputs B 1 ... B 4
Activation time 40 ms
Switch-on voltage 15 V 24 V 30 V
Switch-on current 500 mA

Output circuits (13 - 14, 23 - 24, 33 - 34, 41 - 42, Y 1 - Y 2)


Response time (K 1 / K 2) 20 ms
Relay contacts 3 Normally open contacts (NO), safety relevant
1 Normally closed contact (NC), not safety relevant
1 Normally closed contact (NC), contactor monitoring
Contact type positively guided
Contact material Silver alloy; gold-plated
Load capacity of contacts
Switching voltage 10 V AC/DC 230 V AC / 30 V DC
Switching current 10 mA 6A
Total current across all contacts 12 A
Application Category to EN 60 947-5-1 AC-15 Ue 230 V AC, I e 4 A (360 c/h)
AC-15 Ue 230 V AC, I e 3 A (3600 c/h)
DC-13 Ue 24 V DC, I e 4 A (360 c/h)
DC-13 Ue 24 V DC, I e 2.5 A (3600 c/h)
Permitted switching frequency 3600 c/h
7
Service life, mechanical (switching cycles) 1 x 10
Service life, electrical (dependent on the load) 2 x 10 6

Operating data see Page 47

Weight 0.2 kg

8 009 607/18-09-03 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 9
UE 10-3 OS Series

Order reference list for U E 10-3 OS

Type Outputs Connections Without actual Order No.


Screw type terminals Removable terminals supply voltage

UE 10 - 3 OS 2 D0 6 024 917
UE 10 - 3 OS 3 D0 6 024 918

10 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03
UE 10-4 XT and UE 11-4 DX Series

UE 10-4 XT and UE 11-4 DX


Expansion modules

Application

The UE 10-4 XT and UE 11-4 DX expansion modules


serve to

 Increase the number of output contacts of a main


unit
 UE 11-4 DX has off-delayed outputs (0.5, 1, 2,
3 sec, depending on model)

Features

 NC contact for external device monitoring (EDM)


 Outputs: 4 normally open contacts, 2 normally closed
contacts
 2 LEDs for relays K 1 and K 2 EN 954-1 Same as the main unit
 Available with removable terminals (key coded)
 “A” Housing (see Page 4), width: 22.5 mm

4
2

EDM within
EDM
the main unit

+ C US

z. B.
e. g. UE
UE 10 - 4 XT
10-4 XT
UE UE
43 -43-3
3 MF MF UE
UE 11 - 4 DX
11-4 DX
Basis-Gerät Erweiterungsmodul
Main Unit Expansion module
C US
8 009 607/18-09-03 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 11
UE 10-4 XT and UE 11-4 DX Series

Function

The supply voltage of the expansion module is linked to


an output contact of a main unit. A1 A2 Y1 13 23 33 43 51 61

Upon applying the supply voltage to terminals A 1 and


K1
A 2, relays K 1 and K 2 are energised (the LEDs for
both relays illuminate): The 4 ouput contacts close, the K2
two normally closed contacts and the EDM (feedback)
circuit switch to open circuit status.
Y2 14 24 34 44 52 62
When the output contacts of the standard unit opens
UE 10-4 XT
(e.g. by activation of the Emergency Stop), the relays
K 1 and K 2 de-energise: The normally open contacts
open, and the two normally closed contacts close.

External device monitoring (EDM) A1 A2 Y1 17 27 37 47 55 65


If external device monitoring is implemented in the
connected main unit, then the normally closed contacts
K1
(Y 1 - Y 2) prevent the resetting of the main unit, when
K 1 and/or K 2 do not de-energise. K2

The function of the UE 11-4 DX ...


... corresponds to that of the UE 10-4 XT, but the unit Y2 18 28 38 48 56 66
also has fixed switch off-delay times of 0.5 sec, 1 sec,
UE 11-4 DX
2 sec and 3 sec, depending on the model. They are
achieved by means of capacitors, so that even in the
Internal Circuitry of the UE 10-4 XT and UE 11-4 DX
event of power supply failure the off-delay runs its full
duration in each instance. The delay cannot be
prematurely cancelled. Only after the delay periods have
expired do the relays K 1 and K 2 return to their neutral
rest position.
With the combination of UE 11-4 DX and a main unit,
Stop Category 1 (EN 418) can be realised.

Units ... XT 2 and ... DX 2 have screw type terminals,


Units ... XT 3 and ... DX 3 have removable terminals.

12 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03
UE 10-4 XT and 11-4 DX Series

Technical Data UE 10-4 XT and U E 11-4 DX

min. typ. max.


General System Data
Supply voltage to A 1 - A 2
Electrical output circuit > 25 V AC / 60 V DC PELV
Electrical output circuit < 25 V AC / 60 V DC PELV or SELV
Supply voltage V V (A 1 - A 2)
UE 10-4 XT 20.4 V AC/DC 24 V AC/DC 26.4 V AC/DC
UE 11-4 DX 20.4 V DC 24 V DC 26.4 V DC
Power consumption
AC (UE 10-4 XT only) 2.7 VA
DC UE 10-4 XT / UE 11-4 DX 1.5 W / 2.0 W
Residual ripple in DC mode
(within the limits of V V ) 2.4 V PP
Nominal frequency in AC mode (UE 10-4 XT) 50 Hz 60 Hz
Activation time (after applying the supply voltage)
UE 10-4 XT 25 ms
UE 11-4 DX 75 ms

Output circuits
UE 10-4 XT (13 - 14, 23 - 24, 33 - 34, 43 - 44, 51 - 52, 61- 62, Y 1 - Y 2)
UE 11-4 DX (17 - 18, 27 - 28, 37 - 38, 47 - 48, 55 - 56, 65 - 66, Y 1 - Y 2) off-delayed
Response time of UE 10-4 XT (K 1 / K 2) 40 ms
Switch-off delay time of UE 11-4 DX (depending on type) 0.5, 1, 2 or 3 sec
Influence of the supply voltage 0.5 (%/% ∆U N )
Influence of ambient temperature 0.4 (%/K)
Mean value of error (% + ± 10 ms) ± 20
Dispersion (% + ± 10 ms) ±2
Relay contacts 4 Normally open contacts (NO), safety relevant
2 Normally closed contacts (NC), not safety relevant
1 Normally closed contact (NC), contactor monitoring
Contact type positively guided
Contact material Silver alloy; gold-plated
Load capacity of contacts
Switching voltage 10 V AC/DC 230 V AC / 30 V DC
Switching current 10 mA 6A
Total current across all contacts 12 A
Application Category to EN 60 947-5-1
AC-15 Ue 230 V AC, I e 6 A (3600 c/h)
DC-13 Ue 24 V DC, I e 6 A (360 c/h)
DC-13 Ue 24 V DC, I e 3 A (3600 c/h)
Permitted switching frequency 3600 c/h
7
Service life, mechanical (switching cycles) 1 x 10
Service life, electrical (dependent upon loading) 2 x 10 6

Operating data see Page 47

Weight 0.2 kg

8 009 607/18-09-03 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 13
UE 10-4 XT and 11-4 DX Series

Order reference list for U E 10-4 XT

Type Output Connections Supply voltage Order No.


Screw type terminals Removable terminals 24 V AC/DC

UE 10 - 4 XT 2 D2 6 024 919
UE 10 - 4 XT 3 D2 6 024 920

Order reference list for U E 11-4 DX (with off-delayed outputs)

Typ Output Connections Supply voltage Delay in Order No.


Screw type terminals Removable terminals 24 V DC in secs.

UE 11 - 4 DX 2 D3 0.5 6 024 921


UE 11 - 4 DX 2 D3 1 6 024 922
UE 11 - 4 DX 2 D3 2 6 024 923
UE 11 - 4 DX 2 D3 3 6 024 924
UE 11 - 4 DX 3 D3 0.5 6 024 925
UE 11 - 4 DX 3 D3 1 6 024 926
UE 11 - 4 DX 3 D3 2 6 024 927
UE 11 - 4 DX 3 D3 3 6 024 928

14 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03
UE 23-2 MF Series

UE 23-2 MF
Safety Relay
Manual or Automatic Reset

Application

The UE 23-2 MF Safety Relay serves as a monitoring


module for:

 Emergency Stops (EN 418): for single- or dual-


channel use
 Safety Switches (EN 1088): for single- or dual-
channel use, e. g. on movable guards

Features

 Single-channel control
 Outputs: 2 normally open contacts, 1 normally closed
contact
 2 LEDs: supply voltage, relays K 1, K 2 EN 954-1 Up to Category 4 1 )

 Manual Reset
 Automatic Reset
 Increase in the number of outputs by way of the
expansion units UE 10-4 XT, UE 11-4 DX
2
 External device monitoring (EDM) 1
 Protection Class 2 to EN 50 178
 “D“ Housing (see Page 5), width: 22.5 mm

See Page 53 for sample wiring diagram EDM


EDM

1
) The wires for the input and output signals shall be routed outside the control
cabinet according to the safety category to be used

oder
or

C US

8 009 607/18-09-03 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 15
UE 23-2 MF Series

Function

After applying the supply voltage (LED SUPPLY illumi-


nates), the normally open contacts remain in the open
state. If the connected sensor is not activated (i.e. the
input circuits are closed), then the normally open A1 A2 Y1 Y2 Y3 13 23 31
contacts close immediately in Automatic Reset (LED
“K 1, K 2“ illuminate). In the case of Manual Reset, K1
RESET
this only occurs after pressing the Reset button.
CONTROL
K2
LOGIC
External device monitoring (EDM)
The unit can take over the function of external device
monitoring. The contactor monitoring system monitors
the external relays through their normally closed 14 24 32
contacts.

Manual Reset
For Manual resetting a pushbutton must be connected Internal Circuitry UE 23-2 MF
to terminals Y 1 and Y 3. This Reset is monitored.

Automatic Reset
For Automatic resetting, Y 1 - Y 2 must be linked.

16 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03
UE 23-2 MF Series

Technical Data UE 23-2 MF

min. typ. max.


General System Data
Protection Class 2 according to EN 50 178 between supply circuit / control circuit / output circuits
and between the output circuits mutually
1
Safety Category: EN 954-1 4 )
Stop Category: EN 60 204 0
Supply voltage/Input circuit V S (A 1 - A 2)
UE 23-2 MF 2 D2 20.4 V DC 24 V DC 26.4 V DC
UE 23-2 MF 2 A4 98 V AC 115/120 V AC 132 V AC
UE 23-2 MF 2 A3 196 V AC 230 V AC 253 V AC
Power consumption
AC 2.7 VA
DC 1.6 W
Residual ripple in DC mode
(within the limits of V S ) 2.4 V PP
Nominal frequency in AC mode 50 Hz 60 Hz

Control voltage (Y 1 - Y 2 - Y 3)
Control voltage 40 V DC
Control current 200 mA
Fuse PTC resistor
Reset time
Manual (Y 3) 70 ms
Automatic (Y 2) 600 ms
Galvanic separation (only on AC units) yes

Output circuits (13 - 14, 23 - 24, 31 - 32)


Response time (K 1 / K 2) 30 ms 80 ms
Relay contacts 2 Normally open contacts (NO), safety relevant
1 Normally closed contact (NC), not safety relevant
Contact type positively guided
Contact material Silver alloy; gold-plated
Load capacity of the contacts
Switching voltage 10 V AC/DC 230 V AC / 30 V DC
Switching current 10 mA 6A
Total current across all contacts 12 A
Category to EN 60 947-5-1 AC-15 Ue 230 V AC, I e 4 A (360 c/h)
AC-15 Ue 230 V AC, I e 3 A (3600 c/h)
DC-13 Ue 24 V DC, I e 4 A (360 c/h)
DC-13 Ue 24 V DC, I e 2,5 A (3600 c/h)
Permitted switching frequency 3600 c/h
7
Service life, mechanical (switching cycles) 1 x 10
Service life, electrical (dependent upon loading) 2 x 10 6

Operating data see Page 47

Weight 270 g

1 ) The wires for the input and output signals shall be routed outside the control cabinet according to the safety category to be used

8 009 607/18-09-03 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 17
UE 23-2 MF Series

Order reference list for UE 23-2 MF

Type Outputs Connections Electrical supply Part No.


Screw type terminals 24 V DC 115 - 120 V AC 230 V AC

UE 23- 2 MF 2 D3 6 026 146


UE 23- 2 MF 2 A4 6 026 147
UE 23- 2 MF 2 A3 6 026 148

18 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03
UE 42-2 HD Series

UE 42-2 HD
Safety Relay
for two-hand operation
Automatic Start

Application

The UE 42-2 HD safety relay serves as a monitoring


module for:

 Two-hand controls with Type III C requirements to


EN 574 and to EN 954-1, Category 4
 Two-hand pushbuttons, each with 1 normally open /
1 normally closed contact combinations
 Safety Switches (EN 1088)

Features

 Dual-channel control
 Outputs: 2 normally open contacts, 1 normally
closed contact EN 954-1 Category 4
EN 574 Type III C
 3 LEDs for supply voltage, relay K 1 and relay
K2
 Automatic Start
 Increase in the number of outputs by way of the 2
expansion unit UE 10-4 XT
1
 External device monitoring (EDM)
 Available with removable terminals (key coded)
 “A” Housing (see Page 4), width: 22.5 mm

EDM
EDM
See Page 54 for sample wiring diagrams

C US

C US
8 009 607/18-09-03 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 19
UE 42-2 HD Series

Function

The UE 42-2 HD unit corresponds to EN 574 Type III C.


A prerequisite for the release of the outputs is that the
two inputs (e. g. two-hand pushbuttons) are actuated
within 0.5 sec. A1 A2 Y1 Y2 Y11 Y12 Y14 13 23 31

After applying the supply voltage to the terminals A 1 -


A 2 the LED SUPPLY illuminates to indicate that Feedback Channel 1
electrical power is present. Pressing the two-hand K1
Control-Logic
pushbuttons S 1 and S 2 at the same time (see Page
Channel 2
53 – Sample wiring diagrams) closes the two normally K2
open contacts. Releasing even one of the buttons will
cause the circuits to adopt the open circuit status. Y21 Y22 Y24 14 24 32
A renewed attempt to initiate starting is only possible if
both Start buttons are set to their nominal start position
(for two-hand pushbuttons units: if both have been
released) and the normally closed contact is closed.
Internal Circuitry UE 42-2 HD

External device monitoring (EDM)


The UE 42-2 HD can take over the function of external
device monitoring. The normally closed contacts of the
external relays are switched in series, connected to the
terminals Y 1 - Y 2.

Automatic start
The UE 42-2 HD has an Automatic start facility.

Monitoring of simultaneous activation


The pressing of the Start buttons at the same time is
monitored. Only when both Start buttons are activated
within 0.5 sec do normally open contacts close and the
normally closed contact opens.

The UE 42-2 HD 2 unit has screw type terminals.


The UE 42-2 HD 3 unit has removable terminals.

20 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03
UE 42-2 HD Series

Technical Data U E 42-2 HD

min. typ. max.


General System Data
Supply voltage to A 1 / A 2
Electrical output circuit > 25 V AC / 60 V DC PELV
Electrical output circuit < 25 V AC / 60 V DC PELV or SELV
Safety Category: EN 954-1 4
Supply voltage V S (A 1 / A 2) 20.4 V AC/DC 24 V AC/DC 26.4 V AC/DC
Power consumption
AC 2.7 VA
DC 1.5 W
Residual ripple in DC mode
(within the limits of V S ) 2.4 V PP
Nominal frequency in AC mode 50 Hz 60 Hz

Control voltage (Y 11 - Y 21)


Control voltage 24 V DC
Control current 60 mA
Short-circuit current between Y 11 and A 2 1000 mA
Fuse PTC resistor
Galvanic separation between A 1 / A 2 and Y 11 / Y 21 no

Input circuits (Y 12 - Y 14 and Y 22 - Y 23)


Input current 60 mA
Reset time 40 ms
Activation time tolerance between the two Start buttons 500 ms
Minimum switch-off time 250 ms
Line resistance at the input circuit < 70 Ohm
Switch-on time (upon applying the supply voltage) 250 ms

Output circuits (13 - 14, 23 - 24, 31 - 32)


Response time (K 1 / K 2) 50 ms
Relay contacts 2 Normally open contacts (NO), safety relevant
1 Normally closed contact (NC), not safety relevant
Contact type positively guided
Contact material Silver alloy; gold-plated
Load capacity of contacts
Switching voltage 10 V AC/DC 230 V AC / 30 V DC
Switching current 10 mA 6A
Total current across all contacts 12 A
Application Category to EN 60 947-5-1 AC-15 Ue 230 V AC, I e 4 A (360 c/h)
AC-15 Ue 230 V AC, I e 3 A (3600 c/h)
DC-13 Ue 24 V DC, I e 4 A (360 c/h)
DC-13 Ue 24 V DC, I e 2.5 A (3600 c/h)
Permitted switching frequency 3600 c/h
7
Service life, mechanical (switching cycles) 1 x 10
Service life, electrical (dependent upon loading) 2 x 10 6

Operating data see Page 47

Weight 0.2 kg

8 009 607/18-09-03 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 21
UE 42-2 HD Series

Order reference list for UE 42-2 HD

Type Outputs Connections Electrical supply Part No.


Screw type terminals Removable terminals 24 V AC/DC

UE 42- 2 HD 2 D2 6 024 878


UE 42- 2 HD 3 D2 6 024 881

22 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03
UE 43-2 MF Series

UE 43-2 MF
Safety Relay
Manual or Automatic Reset

Application

The UE 43-2 MF Safety Relay serves as a monitoring module for:

 Emergency Stops (to EN 418): for single- or dual-channel system


use
 Safety Switches (to EN 1088): for single- or dual-channel system
use, e. g. movable guards
 Control systems to EN 954-1 (Category 4)

Features

 Single- or dual-channel control


 Cross circuit detection
 Outputs: 2 normally open contacts, 1 normally closed contacts
 3 LEDs: for supply voltage, relays K 1 and K 2 EN 954-1 Category 4

 Manual Reset
 Automatic Reset
 Increase in the number of outputs by way of the expansion units
UE 10-4 XT, UE 11-4 DX 2
 External device monitoring (EDM) 1
 Available with removable terminals (key coded)
 “A” Housing (see Page 4), width: 22.5 mm

EDM
See Page 55 for sample wiring diagram EDM

o r
oder

C US

C US
8 009 607/18-09-03 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 23
UE 43-2 MF Series

Function

After applying the supply voltage (LED SUPPLY illumi-


nates), the normally open contacts remain in the opened
A1 A2 S34 S35 S12 S31 13 23 31
state. If the connected sensor is not activated (i.e. the + + + +
input circuits are closed), then the normally open
K1
contacts close immediately in Automatic Reset (LED
„K 1, K 2“ illuminate). In the case of Manual Reset, this
K2
only occurs after pressing and releasing the Reset -- + Control-
Logic
button. Activation of the sensor (opening of one or both
input circuits) effects the opening of the normally open
outputs. K1 K2
--
S21 S11 S33 S22 14 24 32
External device monitoring (EDM)
The UE 43-2 MF unit can take over the function of
external device monitoring. The contactor monitoring Internal Circuitry UE 43-2 MF
system monitors the external relays by means of their
normally closed contacts.

Manual Reset
For Manual resetting a pushbutton must be connected to
terminals S 33 - S 34. Reset is monitored.

Automatic Reset
For Automatic resetting, S 12 - S 35 must be linked.

Cross circuit detection


Cross circuit is detected on dual-channel wired systems if
these are wired with opposing polarity.

Monitoring of synchronisation
Only if input 2 closes by no later than 0.5 sec after input
1 do the ouput circuits close. If input 2 closes before
input 1, the monitoring of synchronisation will not be
effected, and the output circuits will close. This
monitoring only takes place in Automatic Reset.

The UE 43-2 MF 2 units have screw type terminals.


The UE 43-2 MF 3 units have removable terminals.

24 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03
UE 43-2 MF Series

Technical Data UE 43-2 MF

min. typ. max.


General System Data
Supply voltage to A 1 / A 2
Electrical output circuit > 25 V AC / 60 V DC PELV
Electrical output circuit < 25 V AC / 60 V DC PELV or SELV
Safety Category: EN 954-1 4
Stop Category: EN 60 204 0
Supply voltage V S (A 1 / A 2) 20.4 V AC/DC 24 V AC/DC 26.4 V AC/DC
Power consumption
AC 4.6 VA
DC 2.1 W
Residual ripple in DC mode
(within the limits of V S ) 2.4 V PP
Nominal frequency in AC mode 50 Hz 60 Hz

Control voltage S 33 / S 11 und S 21


Control voltage 17.4 V DC 22 V DC
Control current 40 mA 100 mA
Short-circuit current between S 33 / S 11 and S 21 2000 mA
Fuse PTC resistor
Reaction time by cross connection 3 s
Activation time upon detection of cross connection 3 s
Galvanic separation between A 1 / A 2 and S 21, S 11, S 33 no

Input circuits (S 12, S 31, S 22, S 34, S 35)


Input current S 12 und S 31 / S 22 40 mA 100 mA
Input current S 34 / S 35 5 mA 50 mA
Reset time
Manual (S 34) 40 ms
Automatic (S 35) 200 ms 500 ms
Activation time of Reset button 50 ms
Line resistance at the input circuit 35 Ohm
Synchronisation time 500 ms

Output circuits (13 - 14, 23 - 24, 31 - 32)


Response time (K 1 / K 2) 25 ms
Minimum time outputs will stay off 40 ms
Relay contacts 2 Normally open contacts (NO), safety relevant
1 Normally closed contact (NC), not safety relevant
Contact type positively guided
Contact material Silver alloy; gold-plated
Load capacity of contacts
Switching voltage 10 V AC/DC 230 V AC / 30 V DC
Switching current 10 mA 6 A
Total current across all contacts 12 A
Application Category to EN 60 947-5-1
AC-15 Ue 230 V AC, I e 4 A (360 c/h)
AC-15 Ue 230 V AC, I e 3 A (3600 c/h)
DC-13 Ue 24 V DC, I e 4 A (360 c/h)
DC-13 Ue 24 V DC, I e 2.5 A (3600 c/h)
Permitted switching frequency 3600 c/h
Service life, mechanical (switching cycles) 1 x 10 7
Service life, electrical (dependent upon loading) 1 x 10 5

Operating data see Page 47

Weight 0.2 kg

8 009 607/18-09-03 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 25
UE 43-2 MF Series

Order reference list for UE 43- 2 MF

Type Outputs Connections Electrical supply Part No.


Screw type terminals Removable terminals 24 V AC/DC

UE 43- 2 MF 2 D2 6 024 893


UE 43- 2 MF 3 D2 6 024 894

26 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03
UE 43-3 MF Series

UE 43-3 MF
Safety Relay
Manual or Automatic Reset

Application

The UE 43-3 MF Safety Relay serves as a monitoring module for:

 Emergency Stops (to EN 418): for single- or dual-channel system


use
 Safety
?
Switches (to EN 1088): for single- or dual-channel system
use,? e. g. on movable guards
 Control systems to EN 954-1 (Category 4)

Features

 Single- or dual-channel control


 Cross circuit detection
 Outputs: 3 normally open contacts, 1 normally closed contact

EN 954-1 Category 4
3 LEDs: for supply voltage, relays K 2 and K 3
 Manual Reset
 Automatic Reset
 Increase in the number of outputs by way of the expansion units
UE 10-4 XT, UE 11-4 DX 3
 External device monitoring (EDM) 1
 “B” Housing (see Page 5), width: 45 mm

See Pages 56 and 57 for sample wiring diagrams


EDM
EDM

oder
or

C US

C US
8 009 607/18-09-03 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 27
UE 43-3 MF Series

Function

After applying the supply voltage (LED SUPPLY illumi-


nates) the normally open contacts remain open. If the A1 A2 Y13 Y14 Y12 Y12 Y31
+ + + +
13 23 33 41
+
connected sensor is not activated (i. e. the input circuits
are closed), the normally open contacts close imme-
K2
diately in Automatic Reset (LED K 2 and K 3 illuminate).
K3
In the case of Manual resetting, this is only effected + --
upon pressing and releasing the Reset button.
Activation of the sensor (opening of one or both input
K1 K2 K3
circuits) effects the opening of the normally open --
Y11 Y21 Y22 14 24 34 42 42
contacts (LED K 2 and K 3 off).

External device monitoring (EDM) Internal Circuitry UE 43-3 MF


The UE 43-3 MF unit can take over the external device
monitoring. The contactor monitoring system monitors
the external relays by way of their normally closed
contacts.

Manual Reset
For Manual resetting a pushbutton must be connected
to terminals Y 12 and Y 13. Reset is monitored.

Automatic Reset
For Automatic resetting Y 12 - Y 14 must be linked.

Cross circuit detection


Cross circuit is detected on dual-channel wired systems,
if these are wired with opposing polarity.

Monitoring of synchronisation
Only if input 2 closes by no later than 0.5 sec after
input 1 do the ouput circuits close. If input 2 closes
before input 1, the monitoring of synchronisation will
not be effected, and the output circuits will close. This
monitoring only takes place in Automatic Reset.

28 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03
UE 43-3 MF Series

Technical Data U E 43-3 MF

min. typ. max.


General System Data
Supply voltage to A 1 / A 2 for DC Units
Electrical output circuit > 25 V AC / 60 V DC PELV
Electrical output circuit < 25 V AC / 60 V DC PELV or SELV
Voltage supply to A 1 / A 2 on AC units Use of earth conductor terminal
Safety Category: EN 954-1 4
Stop Category: EN 60 204 0
Supply voltage V S
UE 43-3 MF 2 D3 20.4 V DC 24 V DC 26.4 V DC
UE 43-3 MF 2 A0 20.4 V AC 24 V AC 26.4 V AC
UE 43-3 MF 2 A1 97.75 V AC 115 V AC 126.5 V AC
UE 43-3 MF 2 A2 102.0 V AC 120 V AC 132.0 V AC
UE 43-3 MF 2 A3 195.5 V AC 230 V AC 253.0 V AC
Power consumption
AC 2.5 W / 3.2 VA
DC 1.0 W
Residual ripple in DC mode
(within the limits of V S) 2.4 V PP
Nominal frequency in AC mode 50 Hz 60 Hz

Control voltage Y 11 and Y 21


Control voltage 24 V DC
Control current 40 mA
Short circuit current between Y 11 and A 2 1000 mA
Fuse
AC units short circuit resistant transformer
DC units PTC resistor
Reaction time by cross connection 3s
Galvanic separation between A 1 / A 2 and Y 11 - Y 21 - PE only on AC units

Input circuits (Y 12 and Y 31 - Y 22)


Input current at Y 12 and Y 31 15 mA
Input current at Y 13 and Y 14 (reset circuit) 40 mA
Reset time
Manual (Y 13) 150 ms 250 ms
Automatic (Y 14) 0.8 s 1.2 s
Synchronisation time 500 ms
Line resistance at the input circuit < 70 Ohm
Input time upon applying supply voltage 100 ms

Output circuits (13 - 14, 23 - 24, 33 - 34, 41 - 42)


Response time (K 2 / K 3) 50 ms
Relay contacts 3 Normally open contacts (NO), safety relevant
1 Normally closed contact (NC), not safety relevant
Contact type positively guided
Contact material Silver alloy; gold-plated
Load capacity of contacts
Switching voltage 10 V AC/DC 230 V AC / 30 V DC
Switching current 10 mA 6A
Total current across all contacts 18 A
Application Category to EN 60 947-5-1 AC-15 Ue 230 V AC, I e 6 A (3600 c/h)
DC-13 Ue 24 V DC, I e 6 A (360 c/h)
DC-13 Ue 24 V DC, I e 3 A (3600 c/h)
Permitted switching frequency 3600 c/h
Service life, mechanical (switching cycles) 1 x 10 7
Service life, electrical (dependent upon loading) 2 x 10 6

Operating data see Page 47

Weight
AC unit 0.36 kg
DC unit 0.30 kg
8 009 607/18-09-03 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 29
UE 43-3 MF Series

Order reference list for UE 43-3 MF

Type Outputs Connections Electrical supply Part No.


Screw type terminals 24 V DC 24 V AC 115 V AC 120 V AC 230 V AC

UE 43- 3 MF 2 D3 6 024 897


UE 43- 3 MF 2 A0 6 024 898
UE 43- 3 MF 2 A1 6 024 899
UE 43- 3 MF 2 A2 6 024 900
UE 43- 3 MF 2 A3 6 024 901

30 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03
UE 43-6 MF Series

UE 43-6 MF
Safety Relay
Manual or Automatic Reset

Application

The UE 43-6 MF Safety Relay serves as a monitoring


module for:

 Emergency Stops (to EN 418): for single- or dual-


channel system use
?
 Safety
? Switches (to EN 1088): for single- or dual-
channel system use, e. g. on movable guards Available as of 2004
 Control systems to EN 954-1 (Category 4)

Features

 Single- or dual-channel control


 Cross circuit detection
 Outputs: 6 normally open contacts, 4 normally closed EN 954-1 Category 4

contacts
 6 LEDs: for supply voltage, CH 1, CH 2, relays K 1,
K 2 and “K 3 RESET“
 Manual Reset
6
 Automatic Reset
4
 Increase in the number of outputs by way of the
expansion units UE 10-4 XT, UE 11-4 DX
 External device monitoring (EDM)
 “C” Housing (see Page 5), width: 90 mm
EDM
EDM

See Page 58 for sample wiring diagram

or
oder

C US

8 009 607/18-09-03 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 31
UE 43-6 MF Series

Function

After applying the supply voltage (LED SUPPLY illumi-


nates), the normally open contacts remain open. If the A1 A2 S34 Y1 S37 S11 S12 13 23 33 43 53 63 71 81 91 01
+
connected sensor is not activated, the LEDs CH 1 and
CH 2 illuminate. In the case of Automatic resetting, the CH 1
normally open contacts close immediately (LED K 1 and RESET
K1
K 2 illuminate). With Manual resetting the normally open CONTROL- LOGIC

contacts only close upon pressing and releasing the EDM


CH 2
K2

Reset button.
– +
The activation of the sensor (opening of one or both
Y1 Y2 S21 S22 Y3 S33 14 24 34 44 54 64 72 82 92 02
input circuits) effects the opening of the normally open
contacts (LED K 1 and K 2 off).
Internal Circuitry UE 43-6 MF
External device monitoring (EDM)
The UE 43-6 MF unit can take over the external device
monitoring. The contactor monitoring system monitors
the external relays by way of their normally closed
contacts.

Manual Reset
For Manual Reset a pushbutton is to be connected to
the terminals S 33 - S 34 and a link connected
between S 12 and Y 3 and between Y 1 and S 37.
This Reset is monitored.

Automatic Reset
For Automatic Reset S 12 - S 34 and Y 3 - S 33 must
be linked.

Cross circuit detection


Cross circuit is detected on dual-channel wired systems,
if these are wired with opposing polarity.

Monitoring of synchronisation
Only if input 2 closes by no later than 0.5 sec after
input 1 do the ouput circuits close. If input 2 closes
before input 1, the monitoring of synchronisation will
not be effected, and the output circuits will close. This
monitoring only takes place in Automatic Reset.

32 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03
UE 43-6 MF Series

Technical Data UE 43-6 MF ( provisional )

min. typ. max.


General System Data
Supply voltage to A 1 / A 2 for DC units
Electrical output circuit > 25 V AC / 60 V DC PELV
Electrical output circuit < 25 V AC / 60 V DC PELV or SELV
Voltage supply to A 1 / A 2 for AC unit Use earth conductor terminal
Safety Category: EN 954-1 4
Stop Category: EN 60 204 0
Supply voltage V S (A 1 / A 2)
UE 43-6 MF 2 D 3 20.4 V DC 24 V DC 26.4 V DC
UE 43-6 MF 2 A 2 102.0 V AC 120 V AC 132.0 V AC
UE 43-6 MF 2 A 3 195.5 V AC 230 V AC 253.0 V AC
Power consumption
AC 4.2 W / 4.5 VA
DC 2.4 W
Residual ripple in DC mode
(within the limits of V S) 2.4 V PP
Nominal frequency in AC mode 50 Hz 60 Hz

Control voltage S 11 and S 21


Control voltage 24 V DC
Control current 40 mA
Short circuit current (between Y 11 and A 2) 1000 mA
Fuse
AC units short circuit resistant transformer
DC units PTC resistor
Reaction time by cross connection (DC unit) 3s
Galvanic separation
between A 1 - 2 and Y 11 - Y 21 - PE only on AC units

Input circuits (S 12 - S 22 and Y 3 - S 22)


Input current 40 mA
Reset time
Manual 350 ms
Automatic 500 ms
Synchronisation time 500 ms
Line resistance at the input circuit 85 Ohm
Switch-on time upon applying the supply voltage (AC units) 100 ms

Output circuits
(13 - 14, 23 - 24, 33 - 34, 43 - 44, 53 - 54, 63 - 64, 71 - 72, 81 - 82, 91 - 92, 01 - 02)
Response time (K 1 / K 2) 60 ms
Relay contacts 6 Normally open contacts (NO), safety relevant
4 Normally closed contacts (NC), not safety relevant
Contact type positively guided
Contact material Silver alloy; gold-plated
Load capacity of contacts
Switching voltage 10 V AC/DC 230 V AC / 30 V DC
Switching current 10 mA 6A
Total current across all contacts 24 A
Application Category to EN 60 947-5-1 AC-15 Ue 230 V AC, I e 3 A (3600 c/h)
DC-13 Ue 24 V DC, I e 2 A (3600 c/h)
Permitted switching frequency 3600 c/h
Service life, mechanical (switching cycles) 1 × 10 7
Service life, electrical (dependent upon loading) 2 × 10 6

Operating data see Page 47

Weight 0.8 kg
8 009 607/18-09-03 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 33
UE 43-6 MF Series

Order reference list for UE 43-6 MF

Type Outputs Connections Electrical supply Part No.


Screw type terminals 24 V DC 120 V AC 230 V AC

UE 43- 6 MF 2 D3 6 024 902


UE 43- 6 MF 2 A2 6 024 905
UE 43- 6 MF 2 A3 6 024 906

34 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03
UE 44-3 SL Series

UE 44-3 SL
Safety Relay
with additional on-delay

Application

The UE 44-3 SL Safety Relay serves as a monitoring


module for:

 Emergency Stops (to EN 418): for single- or dual-


channel system use
 Safety Switches (to EN 1088): for single- or dual-
channel system use, e. g. on movable guards
 Safety Switches with mechanical locking (e. g. i200)
 Control systems to EN 954-1 (Category 4)

Features

 Single- or dual-channel control


 Cross circuit detection EN 954-1 Category 4

 Outputs: 2 normally open contacts, 1 normally open


contact with on-delay, adjustable from 0.15 … 3 sec or
1.5 … 30 sec
 3 LEDs: for supply voltage, relays K 1 / K 2 (without
delay) and relays K 3 / K 4 (on-delayed) 2

 Manual Reset 1 +
 Automatic Reset
 Increase in the number of outputs by way of the
expansion units UE 10-4 XT, UE 11-4 DX
 External device monitoring (EDM) EDM
EDM

 Available with removable terminals (key coded)


 “A” Housing (see Page 4), width: 22.5 mm

See Page 59 for sample wiring diagram

or
oder

C US

i200 C US
8 009 607/18-09-03 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 35
UE 44-3 SL Series

Function

After applying the supply voltage (LED SUPPLY illumi-


nates), the normally open contacts (13 - 14 / 23 - 24)
remain open. After completion of the on-delay set on A1 A2 S33 S34 S35 13 23 37
the relay, the delay circuit (37 - 38) closes, and the +

LED K 3 / K 4 illuminates. If the connected sensor is RESET K1

not activated (i. e. the input circuits are closed), the CONTROL-LOGIC
K2
K3
normally open contacts (13 - 14 / 23 - 24) close Channel 1 Channel 2
(+) (-) K4
immediately during Automatic Reset, the LED K 1 / K 2
illuminates, and the delay circuit (37 - 38) opens (LED + -
S11 S21 S12 S31 S22 14 24 38
K 3 / K 4 off). In the case of Manual Reset, this only
occurs after pressing and releasing the Reset button.
The activation of the sensor (opening of one or both
input circuits) effects the opening of both normally open
contacts (13 - 14 / 23 - 24), with LEDs K 1 / K 2 being
off, and a time delayed closing of the third circuit (37 - Internal Circuitry UE 44-3 SL
38), with LED K 3 / K 4 illuminating.

External device monitoring (EDM)


The unit can take over external device monitoring. The
contactor monitoring system monitors the external
relays by way of their normally closed contacts.

Manual Reset
For Manual resetting, a pushbutton is to be connected
between 24 V DC supply and terminal S 34. This Reset
is monitored. For applications with mechanical locking
safety switches, only channel 2 must be closed during
Manual Reset (see page 59)

Automatic Reset
For Automatic resetting S 12 - S 35 must be linked. For
applications with mechanical locking safety switches,
only channel 1 must be closed during Automatic Reset.

Cross circuit detection


Cross circuit is detected on dual-channel wired systems,
if these are wired with opposing polarity.

Monitoring of synchronisation
Only if input 2 closes by no later than 0.5 sec after
input 1 do the ouput circuits close. If input 2 closes
before input 1, the monitoring of synchronisation will not
be effected, and the output circuits will close. This
monitoring only takes place in Automatic Reset.

The UE 44-3 SL 2 unit has screw type terminals.


The UE 44-3 SL 3 unit has removable terminals.

36 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03
UE 44-3 SL Series

Technical Data U E 44-3 SL

min. typ. max.


General System Data
Supply voltage to A 1 / A 2 for DC units
Electrical output circuit > 25 V AC / 60 V DC PELV
Electrical output circuit < 25 V AC / 60 V DC PELV or SELV
Safety Category: EN 954-1 4
Stop Category: EN 60 204 0
Supply voltage V S 20.4 V DC 24 V DC 26.4 V DC
Power consumption 1.8 W
Residual ripple in DC mode
(within the limits of V S ) 2.4 V PP

Control voltage S 11 - S 33 und S 21


Control voltage 22 V DC
Control current 60 mA
Electrical short circuit between S 11 and A 2 2200 mA
Fuse PTC resistor
Reaction time by cross connection 2s
Galvanic separation
between A 1 / A 2 and S 11 - S 21 no

Input circuits (S 12 and S 31)


Input current at S 12 and S 31 25 mA 100 mA
Input current at S 34 / S 35 (reset circuit) 40 mA 50 mA
Reset time
Manual (S 34) 30 ms
Automatic (S 35) 750 ms
Synchronisation time 500 ms
Activation time of Reset button 250 ms
Line resistance at the input circuit < 85 Ohm

Output circuits (13 - 14, 23 - 24, 37 - 38)


Response time (K 1 / K 2) 25 ms
On-Delay time (K 3 / K 4)
UE 44-3 SL xD3 3 0.15 s 3s
UE 44-3 SL xD3 30 1.5 s 30 s
Relay contacts 2 Normally open contacts (NO), Safety Cat. 4
1 Normally open contact (NO), on-delayed, Safety Cat. 3
Contact type positively guided
Contact material Silver alloy; gold-plated
Load capacity of contacts
Switching voltage 10 V AC/DC 230 V AC / 30 V DC
Switching current 10 mA 6A
Total current across all contacts 12 A
Application Category to EN 60 947-5-1 AC-15 Ue 230 V AC, I e 4 A (3600 c/h)
DC-13 Ue 24 V DC, I e 5 A (360 c/h)
DC-13 Ue 24 V DC, I e 3 A (3600 c/h)
Permitted switching frequency 3600 c/h
Service life, mechanical (switching cycles) 5 x 10 6
Service life, electrical (dependent upon loading) 2 x 10 6

Operating data see Page 47

Weight 0.2 kg

8 009 607/18-09-03 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 37
UE 44-3 SL Series

Order reference list for U E 44-3 SL

Type Outputs Connections Electrical supply Delay in sec. Part No.


Screw type terminals Removable terminals 24 V DC

UE 44- 3 SL 2 D3 3 6 024 907


UE 44- 3 SL 3 D3 3 6 024 908
UE 44- 3 SL 2 D3 30 6 024 909
UE 44- 3 SL 3 D3 30 6 024 910

38 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03
UE 45-3 S1 Series

UE 45-3 S1
Safety Relay
with additional off-delay

Application

The UE 45-3 S1 serves as a monitoring module for:

 Emergency Stops (to EN 418): for single- or dual-


channel system use
 Safety Switches (to EN 1088): for single- or dual-
channel system use, e. g. on movable guards
 Control systems to EN 954-1 (Category 4)

Features

 Single- or dual-channel control


 Cross circuit detection
 Outputs: 2 normally open contacts, 1 normally open
contact with off-delay, adjustable from 0.15 … 3 sec EN 954-1 Category 4
EN 60 204-1 Stop Category 0/1
or 1.5 … 30 sec
 3 LEDs: for supply voltage, relays K 1 / K 2
(without delay) and relays K 3 / K 4 (off-delayed)
 Manual Reset
2
 Automatic Reset
 Increase in the number of outputs by way of the 1 +
expansion units UE 10-4 XT, UE 11-4 DX
 External device monitoring (EDM)
 Available with removable terminals (key coded)
 “A” Housing (see Page 4), width: 22.5 mm EDM
EDM

See Page 60 for sample wiring diagram

oder
or

C US

C US
8 009 607/18-09-03 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 39
UE 45-3 S1 Series

Function

After applying the supply voltage (LED SUPPLY illumi-


nates), the normally open contacts remain open. If the
A1 A2 S33 S34 S35 13 23 37
connected sensor is not activated (i. e. the input circuits +
are closed), the normally open contacts close imme-
RESET K1
diately during Automatic resetting, LED K 1 / K 2 and
K2
K 3 / K 4 illuminate. In the case of Manual resetting, CONTROL- LOGIC
K3
Channel 1 Channel 2
this only occurs after pressing and releasing the Reset (+) (–) K4
button.
+ -
The activation of the sensor (opening of one or both S11 S21 S12 S31 S22 14 24 38

input circuits) effects the opening of both normally open


contacts (13 - 14 / 23 - 24) immediately, and a time
delayed closing of the third circuit (37 - 38), with LED
K 1 / K 2 immeditely going off and K 3 / K 4 going off
Internal Circuitry UE 45-3 S1
later.

External device monitoring (EDM)


The unit can take over external device monitoring. The
contactor monitoring system monitors the external
relays by way of their normally closed contacts.

Manual Reset
For Manual resetting, a pushbutton must be connected
to terminals S 33 - S 34. This Reset is monitored.

Automatic Reset
For Automatic resetting S 33 - S 35 must be linked.

Cross circuit detection


Cross circuit is detected on dual-channel wired systems,
if these are wired with opposing polarity.

Monitoring of synchronisation
Only if input 2 closes by no later than 0.5 sec after
input 1 do the ouput circuits close. If input 2 closes
before input 1, the monitoring of synchronisation will
not be effected, and the output circuits will close. This
monitoring only takes place in Automatic Reset.

The UE 45-3 S1 2 unit has screw type terminals.


The UE 45-3 S1 3 unit has removable terminals.

40 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03
UE 45-3 S1 Series

Technical Data U E 45-3 S1

min. typ. max.


General System Data
Supply voltage to A 1 / A 2
Electrical output circuit > 25 V AC / 60 V DC PELV
Electrical output circuit < 25 V AC / 60 V DC PELV or SELV
Safety Category: EN 954-1 4
Stop Category: EN 60 204 0/1
Supply voltage V S 20.4 V DC 24 V DC 26.4 V DC
Power consumption 2.6 W
Residual ripple in DC mode
(within the limits of V S ) 2.4 V PP

Control voltage S 11 / S 33 and S 21


Control voltage 24 V DC
Control current 60 mA
Electrical short circuit between S 11 and A 2 2200 mA
Fuse PTC resistor
Reaction time by cross connection 2s
Galvanic separation
between A 1 / A 2 and S 11 / S 21 no

Input circuits (S 12 and S 31)


Input current at S 12 and S 31 25 mA 100 mA
Input current at S 34 / S 35 (reset circuit) 40 mA 50 mA
Reset time
Manual (S 34) 30 ms
Automatic (S 35) 600 ms
Synchronisation time 500 ms
Activation time for Reset button 200 ms
Line resistance at the input circuit < 85 Ohm

Output circuits (13 - 14, 23 - 24, 37 - 38)


Response time (K 1 / K 2) 25 ms
Off-delay time (K 3 / K 4)
UE 45-3 S1 xD3 3 0.15 s 3s
UE 45-3 S1 xD3 30 1.5 s 30 s
Relay contacts 2 Normally open contacts (NO), Safety Cat. 4
1 Normally open contact (NO), off-delayed, Safety Cat. 3
Contact type positively guided
Contact material Silver alloy; gold-plated
Load capacity of contacts
Switching voltage 10 V AC/DC 230 V AC / 30 V DC
Switching current 10 mA 6A
Total current across all contacts 12 A
Application Category to EN 60 947-5-1 AC-15 Ue 230 V AC, I e 4 A (3600 c/h)
DC-13 Ue 24 V DC, I e 5 A (360 c/h)
DC-13 Ue 24 V DC, I e 3 A (3600 c/h)
Permitted switching frequency 3600 c/h
Service life, mechanical (switching cycles) 5 x 10 6
Service life, electrical (dependent upon loading) 2 x 10 6

Operating data see Page 47

Weight 0.2 kg

8 009 607/18-09-03 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 41
UE 45-3 S1 Series

Order reference list for UE 45-3 S1

Type Outputs Connections Electrical supply Delay in sec. Part No.


Screw type terminals Removable terminals 24 V DC

UE 45- 3 S1 2 D3 3 6 024 911


UE 45- 3 S1 3 D3 3 6 024 912
UE 45- 3 S1 2 D3 30 6 024 913
UE 45- 3 S1 3 D3 30 6 024 914

42 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03
UE 48-2 OS and UE 48-3 OS Series

UE 48-2 OS and UE 48-3 OS


Safety Relay
Automatic or Manual Reset

Application

The UE 48 Safety Relays serve as a monitoring module for:

 Emergency Stops (to EN 418): for single- or dual-channel system use


 Safety Switches (to EN 1088): for single- or dual-channel system use, e. g.
on movable guards
 Safety Mats in accordance with DIN EN 1760 using 4-wire technology
 Electro-sensitive protective equipment (ESPE) employing monitored
UE 48-3 OS available
semiconductor outputs (OSSD), such as FGS, PLS, C 2000, M 2000,
as of 2004
C 4000, S 3000, LSI, MSL
 Control systems to EN 954-1 (Category 4)

Features

 Single- or dual-channel control EN 954-1


EN 61 496
Category 4
Types 2, 3, 4
 Cross circuit detection
 Outputs
UE 48-2 OS: 2 normally open contacts, 1 normally closed contact 2
UE 48-2 OS
UE 48-3 OS: 3 normally open contacts 1
 3 LEDs: for supply voltage, relays K 1 and K 2
 Manual or Automatic Reset UE 48-3 OS 3
 Increase in the number of outputs by way of the expansion units
UE 10-4 XT, UE 11-4 DX
 External device monitoring (EDM)
 Available with removable terminals (key coded) EDM
EDM

 “A” Housing (See Page 4), width: 22.5 mm

See Pages 61 and 62 for sample wiring diagrams

or
oder

or
oder
1
2
SD
SD
OS SD 1

OS
OS SD

OS
2

or
oder

C US

or
oder

C US
8 009 607/18-09-03 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 43
UE 48-2 OS and UE 48-3 OS Series

Function

After applying the supply voltage (LED SUPPLY illumi-


nates), the normally open contacts remain open. If the
connected sensor is not activated or the protective field
A1 A2 S34 S35 13 23 31
of the connected electro-sensitive protective equipment
(ESPE) is not broken (i. e. the input circuits are closed), RESET
then the normally open contacts close immediately in K1
Control-Logic
Automatic Reset, LED K 1 and K 2 illuminate. In the
K2
CH 1 CH 2
case of Manual resetting, this only occurs after pressing SUPPLY + + –
and releasing the Reset button.
– + +
The activation of the sensor or incursion into the S21 S11 S33 S12 S31 S22 14 24 32

protective field of the non-contact safety device (open


state of one of the two input circuits) effects the
opening of the normally open contacts (LED K 1 and Internal Circuitry UE 48-2 OS
K 2 off).

External device monitoring (EDM)


The unit can take over external device monitoring. The
A1 A2 S33 S34 S35 13 23 33
contactor monitoring system monitors the external
relays by way of their normally closed contacts.
RESET K1
Manual Reset CONTROL-LOGIC
For Manual resetting, a pushbutton must be connected Channel 1 Channel 2 K2
to terminals S 33 - S 34. This Reset is monitored. SUPPLY (+) (+) (–)

– +
Automatic Reset S21 S11 S12 S33 S31 S22 14 24 34
For ESPE’s: S 33 - S 35 must be linked;
for applications with potential free contacts on the input
circuit S 12 - S 35 must be linked.
Internal Circuitry UE 48-3 OS

Cross circuit detection


Cross circuit is detected on dual-channel wired systems,
if these are wired with opposing polarity.

The UE 48-2 OS 2 and UE 48-3 OS 2 units have screw


type terminals.
The UE 48-2 OS 3 and UE 48-3 OS 3 units have
removable terminals.

44 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03
UE 48-2 OS and UE 48-3 OS Series

Technical Data U E 48

min. typ. max.


General System Data
Supply voltage to A 1 / A 2
Electrical output circuit > 25 V AC / 60 V DC PELV
Electrical output circuit < 25 V AC / 60 V DC PELV or SELV
Safety Category: EN 954-1 4
Stop Category: EN 60 204 0
Supply voltage V S (A 1 / A 2) 20.4 V AC/DC 24 V AC/DC 26.4 V AC/DC
Power consumption
AC Mode 4.6 VA
DC Mode 2.1 W
Residual ripple in DC mode
(within the limits of V S ) 2.4 V PP
Nominal frequency in AC mode 50 Hz 60 Hz

Control voltage S 33 / S 11 and S 21


Control voltage 17.4 V DC 22 V DC
Control current 40 mA 100 mA
Electrical short circuit between S 33 / S 11 and S 21) 300 mA
Fuse Electronic Fuse
Reaction time by cross connection 50 ms
Switch-on time after cross connection detection 50 ms
Galvanic separation
between A 1 / A 2 and S 21, S 11, S 33 no

Input circuits (S 12, S 31, S 22, S 34, S 35)


Input voltage (S 12 and S 31)
HIGH 17.4 V DC 26.4 V DC
LOW –3 V DC +5 V DC
Input current at S 12 and S 31 / S 22 40 mA 100 mA
Input current at S 34 / S 35 5 mA 50 mA
Reset time
Manual (S 33 / S 34) 40 ms
Automatic (ESPE: S 33 / S 35; potential free: S 12 / S 35) 80 ms
Activation time for Reset button 50 ms
Minimum switch-off time / minimum switch-on time 7 ms
Permitted test pulse time / Test frequency 1000 µs / 10 s –1
Line resistance at the input circuit 35 Ohm
Synchronisation time 70 ms

Output circuits (13 - 14, 23 - 24, 31 - 32 / 33 - 34)


Response time (K 1 / K 2) 25 ms
Minimum switch-off time 70 ms 130 ms
Relay contacts UE 48-2 OS 2 Normally open contacts (NO), safety relevant
1 Normally closed contact (NC), not safety relevant
Relay contacts UE 48-3 OS 3 Normally open contacts (NO), safety relevant
Contact type positively guided
Contact material Silver alloy; gold-plated
Load capacity of contacts
Switching voltage 10 V AC/DC 230 V AC / 30 V DC
Switching current 10 mA 6 A
Total current across all contacts 12 A
Application Category to EN 60 947-5-1 AC-15 Ue 230 V AC, I e 4 A (360 c/h)
AC-15 Ue 230 V AC, I e 3 A (3600 c/h)
DC-13 Ue 24 V DC, I e 4 A (360 c/h)
DC-13 Ue 24 V DC, I e 2.5 A (3600 c/h)
Permitted switching frequency 3600 c/h
Service life, mechanical (switching cycles) 1 x 10 7
Service life, electrical (dependent upon loading) 2 x 10 6

Operating data see Page 47

Weight 0.2 kg

8 009 607/18-09-03 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 45
UE 48-2 OS and UE 48-3 OS Series

Order reference list for U E 48

Type Outputs Connections Electrical supply Part No.


Screw type terminals Removable terminals 24 V AC/DC

UE 48 - 2 OS 2 D2 6 024 915
UE 48 - 2 OS 3 D2 6 024 916
UE 48 - 3 OS 2 D2 6 025 089
UE 48 - 3 OS 3 D2 6 025 097

46 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03
UE 10 - UE 48 Safety Relays

Common Technical Specifications

min. typ. max.

Surge voltage rating (V Imp. ) 4 kV


Excess Voltage Category III
Contamination rating of the unit (EN 50 178)
external 3
internal 2
Voltage rating 300 V AC
Test voltage V eff (50 Hz) EN 60 439-1 2.0 kV
Protection type
Housing IP 40
Terminals IP 20
Radio interference DIN EN 61 000-6-4
UE 10-4 XT, UE 11-4 DX, UE 42-2 HD,
UE 44-3 SL and UE 45-3 S1 only EN 60 947-1 02/99
Screening against interference DIN EN 61 000-6-2
UE 10-4 XT, UE 11-4 DX, UE 42-2 HD,
UE 44-3 SL and UE 45-3 S1 only EN 60 947-1 02/99
Ambient operating temp. –25 °C +55 °C
Storage temperature –25 °C +75 °C
Cross sections of electrical conductors
single strand wire (2 x, identical cross section) 0.14 mm 2 0.75 mm 2
single strand wire (1 x) 0.14 mm 2 2.5 mm 2
fine stranded wire with terminal crimps
(2 x, identical cross section) 0.25 mm 2 0.5 mm 2
fine stranded wire with terminal crimps (1 x) 0.25 mm 2 2.5 mm 2
UE 43-3 MF and UE 43-6 MF only
single strand wire (2 x, identical cross section) 0.75 mm 2 2.5 mm 2
single strand wire (1 x) 0.75 mm 2 2.5 mm 2
fine stranded wire with terminal crimps
(2 x, identical cross section) 0.5 mm 2 1.5 mm 2
fine stranded wire with terminal crimps (1 x) 0.5 mm 2 1.5 mm 2

8 009 607/18-09-03 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 47
UE 10 - UE 48 Safety Relays

Glossary

Activation time of Time in which a Reset button must be pressed, in order to


Reset button ensure the resetting of the safety relay.
Minimum The minimum time the inputs need to stay off in order for
switch-off time (Inputs) the unit to recognise an off signal. Times under this value
may not be recognised as an off signal.
Minimum The unit specific minimum time the outputs must stay off.
switch-off time (Outputs) This insures that the internal relays can fall back to their
rest state.
Minimum switch-on time The minimum time the inputs need to be HIGH before a
Restart can be enabled.
Monitoring of The simultaneous pressing of the Start buttons is
simultaneous activation monitored, and is specified for two-hand control systems.
(UE 42-2 HD only) Only when both safety input signals change their state
within 0.5 sec will the output contacts be switched.
Off-delay time Time by which the switching off of the output contacts is
delayed. This time is either fixed or adjustable depending
on module type.
On-delay time Time by which the switching on of the output contacts is
delayed. For safety relays having an on-delay, the time
settings are adjustable.
Reset time Time period between the activation of the Reset and
when the ouput contacts switch on.
The time starts:
- during Manual Reset with the release of the Reset
button
- during Automatic Reset with the closing of the input
circuits (e. g. closing of the door).
Response time The time between the activation of the inputs (e. g.
E Stop is pressed), and the switching off of the outputs.
Switch-on time Time, which the safety device needs after applying the
supply voltage in order to be ready for operation.
Synchronisation time Switching of the input circuits within a fixed time span is
monitored. Only if input 2 closes by no later than 0.5 sec
after input 1 do the ouput circuits close. If input 2 closes
before input 1, the monitoring of synchronisation will not
take place, and the output circuits will close. This
monitoring occurs in Automatic Reset.

48 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03
Safety Navigator

Application Overview

General notes Applications Outputs Features

Safety mats (only available in 4-wire technology)

Electro-Sensitive Protective Equipment (ESPE)


Two-hand control systems (Typ III C / EN 574)

Monitoring of simultaneous activation (0.5 s)

Synchronisation monitoring (0.5 s)


Normally closed contacts (NC)

Single-channel control system


Normally open contacts (NO)
Safety Category to EN 954-1

Dual-channel control system


Emergency Stop (EN 418)

Manual Reset (monitored)


Safety Switch (EN 1088)

Cross circuit detection

Housing width (mm)


Expansion module

Automatic Reset
Standard unit

Off-delay
On-delay

UE 42-2 HD 4    2 1    22.5

UE 23-2 MF 4 1)    2 1    22.5

UE 43-2 MF 4    2 1       22.5

UE 43-3 MF 4    3 1       45

UE 43-6 MF 4    6 4       90

UE 10-3 OS 2
)   3 1   22.5

UE 48-2 OS 4      2 1      22.5

UE 48-3 OS 4      3 0      22.5

UE 44-3 SL 4    2        22,5

UE 45-3 S1 4    2        22.5

UE 10-4 XT 3
)  4 2 22.5

UE 11-4 DX 3
)  4/2 4 ) 22.5

1
) The wires for the input and output signals shall be routed outside the control cabinet according to the safety category to be used
2
) Same as protective device
3
) Same as the main unit
4
) 4 normally open contacts / 2 normally closed contacts with off-delay function

8 009 607/18-09-03 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 49
Sample wiring diagrams

Contents

UE 10-3 OS
with C 4000 Safety Light Curtain......................................... 51
with C 2000 Safety Light Curtain......................................... 52
with S 3000 Safety Laser Scanner ..................................... 52

UE 23-2 MF
with Emergency Stop ................................................................... 53

UE 42-2 HD
with two-hand control .................................................................. 54
with two Safety Switches .......................................................... 54

UE 43-2 MF
with two i10 Safety Switches ................................................. 55

UE 43-3 MF
with two Safety Switches .......................................................... 56
with Emergency Stop ................................................................... 57

UE 43-6 MF
with two Safety Switches .......................................................... 58

UE 44-3 SL
with Mechanical Locking Safety Switch ............................. 59

UE 45-3 S1
with two Safety Switches .......................................................... 60

UE 48-2 OS
with C 4000 Safety Light Curtain......................................... 61
with FGS Safety Light Curtain ................................................ 61
with PLS Safety Laser Scanner .............................................. 62

50 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03
UE 10 - UE 48 Safety Relays

Sample wiring diagrams UE 10-3 OS

+ 24 V

S1

2 + 24 V 2
+ 24 V
5 Test 1
RES
1 n. c. 4
EDM
3 n. c. 5
OSSD 1
4 n. c. 6
OSSD 2
7 0V 7
0V
FE FE FE
FE
B1 B3 Y 1 13 23 33 41

C 4000 S C 4000 R UE 10-3 OS

B2 B4 Y 2 14 24 34 42

0V

C 4000 Micro connected to UE 10-3 OS Safety Relay,


with Manual Reset and external device monitoring (active)

+ 24 V

S1

1 + 24 V 1
+ 24 V
3 Test 5
RES
4 n. c. 6
EDM
5 n. c. 3
OSSD 1
6 n. c. 4
OSSD 2
2 0V 2
0V
FE FE FE
FE
B1 B3 Y 1 13 23 33 41

C 4000 S C 4000 R UE 10-3 OS

B2 B4 Y 2 14 24 34 42

0V

C 4000 Standard/Advanced connected to UE 10-3 OS Safety Relay,


with Manual Reset and external device monitoring (active)

8 009 607/18-09-03 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 51
UE 10 - UE 48 Safety Relays

Sample wiring diagrams UE 10-3 OS

+ 24 V

S1

6 2
WH 1 1 WH
Sel 1 Sel 1
BN 2 2 BN
+24 V +24 V
GN 3 3 GN
Sel 2 Sel 2
4 4 YE
n. c. EDM
GY 5 5 GY
Test OSSD 1
6 n. c. 6 PK
OSSD 2
BU 7 7 BU
0V 0V
8 8 B1 B3 Y 1 13 23 33 41
Shield Shield

UE 10-3 OS
C 2000 S C 2000 R
B2 B4 Y 2 14 24 34 42

0V

C 2000 Advanced to UE 10-3 OS Safety Relay,


with Manual Reset and external device monitoring (active)

+ 24 V

S1

1 BN
5 RD
S 3000
6 YE
7 BU/WH
8 RD/BU
9 WH/BN
4 PK
3 GN
2 BU

B1 B3 Y 1 13 23 33 41

UE 10-3 OS

B2 B4 Y 2 14 24 34 42

0V

S 3000 Standard to UE 10-3 OS Safety Relay,


with Manual Reset and external device monitoring (active)
52 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03
UE 10 - UE 48 Safety Relays

Sample wiring diagram U E 23-2 MF

+24 V

S1

Y1 A1 13 23 31
S0
k1 UE 23-2 MF

Y3 A2 14 24 32
k2

K1 K2
0V

Emergency Stop to UE 23-2 MF Safety Relay,


with Manual Reset and external device monitoring (EDM)

8 009 607/18-09-03 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 53
UE 10 - UE 48 Safety Relays

Sample wiring diagrams U E 42-2 HD

+ 24 V

S1 S2
Y12 S14 Y22 Y24 A1 13 23 31

UE 42-2 HD

Y11 Y21 Y1 Y2 A2 14 24 32

k1 k2
K1 K2

0V

Two-hand control with UE 42-2 HD Safety Relay,


dual-channel system, with automatic start and external device monitoring (EDM)

+ 24 V

Y12 S14 Y22 Y24 A1 13 23 31

UE 42-2 HD

Y11 Y21 Y1 Y2 A2 14 24 32

k1 k2
K1 K2

0V

Two Safety Switches connected to UE 42-2 HD Safety Relay,


dual-channel system, with Automatic Reset and external device monitoring (EDM)
54 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03
UE 10 - UE 48 Safety Relays

Sample wiring diagram U E 43-2 MF

+24 V

S1
21 13
i10 S33 S11 S31 S21 A1 13 23 31
22 14
B2 k1 UE 43-2 MF

21 13 S34 S35 S12 S22 A2 14 24 32


i10 k2
22 14
B1

H4
(rd) K1 K2
0V

Two Safety Switches i 10 to UE 43-2 MF Safety Relay,


dual-channel control system, with Manual Reset and external device monitoring (EDM)

8 009 607/18-09-03 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 55
UE 10 - UE 48 Safety Relays

Sample wiring diagrams UE 43-3 MF

+ 24 V

S1

Y14 Y13 Y11 Y21 A1 13 23 33 41

k1 UE 43-3 MF 2 D3

Y31 Y12 Y12 Y22 A2 14 24 34 42


k2

K1 K2

0V

Two Safety Switches to UE 43-3 MF Safety Relay,


dual-channel system, with Manual Reset and external device monitoring (EDM)

+ 24 V

Y14 Y13 Y11 Y21 A1 13 23 33 41

k1
UE 43-3 MF 2 D3

k2 Y31 Y12 Y12 Y22 A2 14 24 34 42

K1 K2

0V

Two Safety Switches to UE 43-3 MF Safety Relay,


dual-channel system, with Automatic Reset and external device monitoring (EDM)

56 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03
UE 10 - UE 48 Safety Relays

Sample wiring diagrams UE 43-3 MF

+ 24 V + 24 V

A) B)
S1 S1

k1 k1

k2 k2

S0 S0
Y13 Y11 Y14 A1 13 23 33 41 Y13 Y11 Y14 A1 13 23 33 41

UE 43-3 MF 2 D3 UE 43-3 MF 2 D3

Y31 Y12 Y21 Y22 A2 14 24 34 42 Y31 Y12 Y21 Y22 A2 14 24 34 42

K1 K2 K1 K2

0V 0V

Emergency Stop Switch connected to UE 43-3 MF 2 D3 Safety Relay,


with Manual Reset and external device monitoring. A) single-channel system, B) dual-channel system

8 009 607/18-09-03 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 57
UE 10 - UE 48 Safety Relays

Sample wiring diagram U E 43-6 MF

+24 V

k1

23 11 k2
B2
i12 SA
24 12
i16 S

S21 S11 S33 Y3 Y1 Y2 A1 13 23 33 43 53 63 71 81 91 01

UE 43-6 MF
11 23
S22 S12 S34 S 37 Y1 A2 14 24 34 44 54 64 72 82 92 02
12 24

B1
i12 SA
i16 S

S1

K1 K2

0V

Two Safety Switches to UE 43-6 MF Safety Relay,


dual-channel system, with Manual Reset and external device monitoring (EDM)

58 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03
UE 10 - UE 48 Safety Relays

Sample wiring diagram U E 44-3 SL

+ 24 V

S1
S4

k1

k2
11 21 33 41 53 E1

S11 S21 S35 S34 A1 13 23 37

UE 44-3 SL

S33 S31 S12 S22 A2 14 24 38

i200 Lock 12 23 34 42 54 E2

K1 K2

0V

i200 Lock Safety switch (with mechanical locking) connected to UE 44-3 SL Safety Relay,
with Manual Reset and external device monitoring (EDM)

8 009 607/18-09-03 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 59
UE 10 - UE 48 Safety Relays

Sample wiring diagram U E 45-3 S1

+ 24 V

S1

k1

k2

S21 S35 S34 S33 A1 13 23 37

UE 45-3 S1

S11 S31 S12 S22 A2 14 24 38

K1

K2 M
3
0V

Two Safety Switches connected to UE 45-3 S1 Safety Relay,


dual-channel system, with Manual Reset and external device monitoring (EDM)

60 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03
UE 10 - UE 48 Safety Relays

Sample wiring diagrams U E 48-2 OS

+ 24 V

1 1
+ 24 V + 24 V
3 5
Test n. c.
4 6
n. c. n. c.
5 3
n. c. OSSD 1
6 4
n. c. OSSD 2
2 2
0V 0V
FE FE S1
FE FE

S33 S11 S12 S31 A1 13 23 31


C 4000 S C 4000 E

k1 UE 48-2 OS

S34 S35 S21 S22 A2 14 24 32


k2

K1 K2

0V

C 4000 Basic to UE 48-2 OS Safety Relay,


with Manual Reset and external device monitoring (EDM)

+ 24 V

1 1
+ 24 V + 24 V
3 3
Test OSSD 1
4 4
Test OSSD 2
2 2
0V 0V
7 7
PE PE S1

S33 S11 S12 S31 A1 13 23 31


FGSS FGSE

k1 UE 48-2 OS

S34 S35 S21 S22 A2 14 24 32


k2

K1 K2

0V
PE

FGS connected to UE 48-2 OS Safety Relay,


with Manual Reset and external device monitoring (EDM)

8 009 607/18-09-03 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 61
Safety Relays UE 10 - UE 48

Sample wiring diagrams U E 48-2 OS

+ 24 V

3
9
8
1

PLS

S1

S33 S11 S12 S31 A1 13 23 31

k1 UE 48-2 OS

S34 S35 S21 S22 A2 14 24 32


k2

K1 K2
0V

PLS connected to UE 48-2 OS Safety Relay,


with Manual Reset and external device monitoring (EDM)

62 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 8 009 607/18-09-03
8 009 607/18-09-03 © SICK AG • Industrial Safety Systems • Germany • Specifications subject to change without notice 63
Contact:

A us t ra l i a
Phone +61 3 9497 4100
1800 33 48 02 – tollfree
E-Mail sales@sick.com.au
B e l g i q u e / L u x e m b o u rg
Phone +32 (0)2 466 55 66
E-Mail info@sick.be
B r a s i l
Phone +55 11 5091-4900
E-Mail sac@sick.com.br
Ce s k á R e p u b l i k a
Phone +420 2 57 91 18 50
E-Mail sick@sick.cz
Chin a
Phone +852-2763 6966
E-Mail ghk@sick.com.hk
D an m a rk
Phone +45 45 82 64 00
E-Mail sick@sick.dk
D e u t s c h l a n d
Phone +49 (0)2 11 53 01-260
E-Mail vzdinfo@sick.de
E sp a ñ a
Phone +34 93 480 31 00
E-Mail info@sick.es
F r a n c e
Phone +33 1 64 62 35 00
E-Mail info@sick.fr
8 009 607/18-09-03 • KW/SM • Printed in Germany (12.03) • Subject to change without prior notice • The specified product features and technical data do not represent any guarantee • int 14.02 TB

Gr ea t B ri t a i n
Phone +44 (0)1727 831121
E-Mail info@sick.co.uk
I ta l i a
Phone +39 02 27 40 93 19
E-Mail ced@sick.it
J ap a n
Phone +81 (0)3 3358 1341
E-Mail info@sick.jp
K or e a
Phone +82-2 786 6321/4
E-Mail kang@sickkorea.net
Ne d e rl a n d
Phone +31 (0)30 229 25 44
E-Mail info@sick.nl
Nor g e
Phone +47 67 81 50 00
E-Mail austefjord@sick.no
Öst e rre i c h
Phone +43 (0)22 36 62 28 8-0
E-Mail office@sick.at
Pols k a
Phone +48 22 837 40 50
E-Mail info@sick.pl
Sch w e i z
Phone +41 41 619 29 39
E-Mail contact@sick.ch
Sin g a p o r e
Phone +65 6744 3732
E-Mail admin@sicksgp.com.sg
Suo m i
Phone +358-9-25 15 800
E-Mail sick@sick.fi
Sv eri g e
Phone +46 8 680 64 50
E-Mail info@sick.se
T ai w a n
Phone +886 2 2365-6292
E-Mail sickgrc@ms6.hinet.net
U SA/ C a n a d a / Mé x i c o
Phone +1(952) 941-6780
1 800-325-7425 – tollfree
E-Mail info@sickusa.com

More representatives and agencies


in all major industrial nations at
www.sick.com

SICK AG • Industrial Safety Systems • Waldkirch • Germany • www.sick.com

You might also like