Professional Documents
Culture Documents
October 2007
DN0987
BreezeMAX Firmware Upgrade Procedure Contents
BreezeMAX DN0987
ii
BreezeMAX Firmware Upgrade Procedure Contents
Contents
Scope ..............................................................................................................1
BreezeMAX DN0987
iii
BreezeMAX Firmware Upgrade Procedure Scope
Scope
This document describes the BreezeMAX firmware upgrade procedure,
using monitor and TFTP DOS commands. This procedure is applicable for
both Modular Base Station (MacroBST ) and Micro Base Station (μBST).
The official firmware versions given in Table 1 below refer to 3300, 3600
and 3500 frequencies. However, the menu captures refer to the BreezeMAX
3500 as an example.
Verify correct BST boot version (refer to section Verifying Boot Version):
NOTE
The upgrade procedure can also be performed using AlvariSTAR. For instructions please
refer to “The Software Upgrade Manager” section in the AlvariSTAR User Manual.
BreezeMAX DN0987
11
BreezeMAX Firmware Upgrade Procedure Verifying Boot Version
MacroBS: 1.0.1.59
MicroBS: 1.0.2.20
=================================== ================================================
>1 >1
NOTE
If the Boot SW Version is not displayed on screen, contact Alvarion Customer Service.
BreezeMAX DN0987
22
BreezeMAX Firmware Upgrade Procedure Firmware Upgrade Procedure
Modular AU au_3_0_1_14.bz
Micro BS micro_3_0_1_16.res
Verify the connection, PING the unit's IP address, and verify that the
PING replies are being received.
NOTE
Prior to uploading the SU firmware file to the BST, verify that no more than two SU firmware
files already exist on the flash. (The same applies for the AU regarding the MacroBST).
2. To perform the upgrade, use a DOS TFTP utility with the following
syntax:
tftp -i hostaddress put sourcefile
Where -i stands for binary mode and hostaddress stands for the IP
address of the unit to be upgraded (the management IP). put instructs
the PC client to send a file to the hostaddress. sourcefile is the name of
the firmware file in the PC Client.
IMPORTANT
The command line should be performed from the path, which holds the files for upgrade.
BreezeMAX DN0987
33
BreezeMAX Firmware Upgrade Procedure Firmware Upgrade Procedure
NOTE
It is recommended to upgrade all system elements with the latest software version.
4. When uploading a firmware file, the unit decompresses the loaded file
and checks the integrity of the new version. The new version replaces
the previous shadow version only after verification. If verification test
fails, the loaded version will be rejected. The unit will reject a file if
either the file name or the version number matches the current main
versions.
After the NPU is up and running with the new version, the
AUs/CPEs are upgraded to the new version.
5. After uploading the relevant firmware files to the BST, check their
existence as shown below:
BreezeMAX/NPU 172.17.31.215 BreezeMAX/uBST 172.17.31.215
SW Version 2.5.2.16 SW Version 2.5.2.15
NPU-Unit Control-SW Version Control MicroBaseStation-Unit Control-SW Version
Control
===================================
=========================================
1 - Show Versions =======
2 - Run from Shadow 1 - Show Versions
3 - Set as Main 2 - Run from Shadow
>1 3 - Set as Main
Main SW File : npu_2_5_2_16 >1
Main SW Version : 2.5.2.16 Main SW File : micro_2_5_2_15.res
Shadow SW File : npu_3_0_1_16 Main SW Version : 2.5.2.15
Shadow SW Version : 3.0.1.16
Shadow SW File : micro_3_0_1_16.res
Running From : Main
Shadow SW Version : 3.0.1.16
Figure 3: NPU version 3.0.1 has been Figure 4: μBST version 3.0.1 has been
uploaded successfully uploaded successfully
BreezeMAX DN0987
44
BreezeMAX Firmware Upgrade Procedure Firmware Upgrade Procedure
BreezeMAX/NPU 172.17.31.215
SW Version 2.5.2.16 SU-SW Files in NPU
==================
1 - Show Files
2 - Default File Name
3 - Default Action
4 - Delete a File
>1
SW File : su_3_0_1_14.bz, Version Rel_3_0_1_14
BreezeMAX/NPU 172.17.31.215
SW Version 2.5.2.16
AU-SW Files in NPU
==================
1 - Show Files
2 - Delete a File
>1
Figure 6: AU version 3.0.1 has been uploaded successfully (relevant for ModularBST only)
6. After verifying the successful upload of all firmware files, set version to
be the main version on each one of the system elements:
IMPORTANT
Setting a version as the main version requires reset. Therefore, system downtime occurs.
BreezeMAX DN0987
55
BreezeMAX Firmware Upgrade Procedure Firmware Upgrade Procedure
software. Repeat this action for all other AUs that need to be
upgraded.
BreezeMAX DN0987
66