Hydrology Report

Hydraflow Express Extension for Autodesk® AutoCAD® Civil 3D® by Autodesk, Inc. viernes, Nov 16 2018

MICROCUENCA ANGASCCOCHA

Hydrograph type = Rational Peak discharge (cms) = 5.8362


Storm frequency (yrs) = 100 Time interval (min) = 1
Drainage area (ha) = 178.780 Runoff coeff. (C) = 0.4
Rainfall Inten (in/hr) = 1.166 Tc by Kirpich (min) = 13
IDF Curve = SampleExpress.IDF Rec limb factor = 1.00

Hydrograph Volume = 4,552 (cum)

Runoff Hydrograph

Q (cms) 100-yr frequency Q (cms)


5.9500 5.9500

5.1000 5.1000

4.2500 4.2500

3.4000 3.4000

2.5500 2.5500

1.7000 1.7000

0.8500 0.8500

0.0000 0.0000
0 5 10 15 20 25 30
Time (min)
Runoff Hyd - Qp = 5.8362 (cms)