Professional Documents
Culture Documents
com
Warranty.
A copy of the specific warranty terms applicable to your Raisecom product and replacement parts
can be obtained from Service Office.
All rights are reserved. No part of this document may be photocopied, reproduced, or translated to
another language without the prior written consent of Raisecom Technology Co., Ltd. The
information contained in this document is subject to change without notice.
Copyright Notices.
No part of this publication may be excerpted, reproduced, translated or utilized in any form or by any
means, electronic or mechanical, including photocopying and microfilm, without permission in
Writing from Raisecom Technology Co., Ltd.
Trademark Notices
Microsoft Corporation.
Contact Information
Technical Assistance Center
The Raisecom TAC is available to all customers who need technical assistance with a Raisecom
product, technology, or, solution. You can communicate with us through the following methods:
Add: 1120, Haitai Tower, 229 Fourth North Loop Middle Road, Haidian District, Beijing
100083
You can access the most current Raisecom product information on the World Wide Web at the
following URL:
http://www.raisecom.com
Feedback
Comments and questions about how the NView iEMS system software works are welcomed. Please
review the FAQ in the related manual, and if your question is not covered, send email by using the
following web page:
http://www.raisecom.com/en/xcontactus/contactus.htm.
If you have comments on the NView iEMS specification, instead of the web page above, please send
comments to:
export@raisecom.com
Audience
This manual is for users of NView NNM product.
Relevant Manual
《NView NNM V5.0 User Manual》
Organization
This manual serves as an installation and deployment guide for NView NNM V5.0. It describes how
to get the NView NNM system running.
Chapter 1 Installation Preparation: The basic preparation and the prerequisites that must be
satisfied for installing and running NView NNM V5.0.
Chapter 2 NView NNM System Installation Steps: Describes the steps for installing NView NNM
system.
Chapter 3 NView NNM System Upgrade Steps: Describes how to upgrade NView NNM V4.2 to
V5.0 or how to upgrade NView iEMS V2.0 to NView NNM V5.0.
Chapter 4 The Start and Stop of NView NNM System: Introduces how to start or stop NView
NNM system
Chapter 5 EMS Installation Steps: Mainly describe the steps for installing NView series EMS.
Chapter 6 Uninstall NView NNM System: Introduces how to uninstall NView NNM system.
Chapter 7 FAQ: Describe the problems that may occur during the installing and running of NView
NNM system and the ways of solving these problems.
www.raisecom.com User Manual
1.1 Overview
The network management system NView NNM V5.0 is the upgrade version of NView NNM V4.0. It
is developed by Raisecom Technology Co., Ltd. NView NNM V5.0 system not only provides all
functions NNM V4.0 can provide, but adopts lots of features and advantages from NView iEMS
system and NView OneTouch system, which greatly enhance the functionality and usability of the
system.
Using the installation program for NView NNM V5.0 system, users can either deploy NView NNM
V5.0 system completely or upgrade existing NView NNM V4.2 system to V5.0 system and reserve
all V4.2 system data. The installation program for NView NNM V5.0 system adopts a guidance
manner. Users only need to select an installation mode, and follow the guidance to complete the
installation step by step. The installation process is easy to handle.
Chapter 2 of this manual introduces the installation and deployment of NView NNM V5.0 system; it
is for users who use NView NNM system for the first time. Chapter 3 of this manual describes the
process of upgrade existing NView NNM V4.2 system to V5.0 version. Users of NView NNM V4.0
system can drop Chapter 2 and refer to Chapter 3 directly for upgrade.
satisfied:
¾ Before conducting a complete installation of NNM system, please make sure that no other
network management system exists on the target host. If there is any other network
management system on the host, please uninstall it first. If the existing network management
is NView NNM V4.2 system, please choose to upgrade it to V5.0 during the installation. For
details, please refer to Chapter 3.
¾ Please make sure that the “SNMP Trap Receiving Service” of Windows OS system services
on the target host has been stopped.
0 Warning: The presence of other SNMP network management systems on the target host
where NNM Server will reside is strictly forbidden in system deployment process. This may
lead to system failure due to reasons such as resource occupation. A most typical instance is the
failure of receiving trap information correctly caused by port 162 occupation.
¾ Standalone deployment scheme: The standalone deployment scheme installs client, server,
and database on one PC. This scheme is suitable for concentrated management and
maintenance based on management center.
¾ Distributed deployment scheme: The distributed deployment scheme installs the complete
system on a host adopting the typical deployment scheme, installs client on other hosts, and
connects all clients on to one host. This scheme meets the requirement of remote, multi-client
management.
The two deployment schemes can be realized by different options in the installation process. Users
can choose either of the two according to need.
L Note: If the system is deployed distributedly, to upgrade the system (including installing
service packs, EMS and application components), users have to install the upgrade program on
the host where the server resides and install corresponding upgrade program on the hosts
where the clients resides.
2
www.raisecom.com User Manual
After setup language selection, please click <Next> to continue the installation.
3
www.raisecom.com User Manual
When process of copying installation files completes, the welcome interface will show up (see
Figure 2-3).
The content in the window shown in Figure 2-4 is a detailed description of the agreement concerning
network management software product of Raicecom. Please read with caution before installation. If
you accept the agreement totally, please click <Yes>, the system will enter the interface for
installation mode selection. In case of any disagreement towards some items or all items of the
agreement, please click <No> to quit the installation.
5
www.raisecom.com User Manual
¾ <Install NView NNM V5.0 Version>: This is the typical installation, which will complete a
standalone deployment scheme. Please click this button to continue a typical installation.
¾ <Install Client>: Clicking this button, the system will start an installation following
distributed deployment scheme and enter the server selection step (see Figure 2-6).
¾ <Update NView NNM Version to NView NNM V5.0>: Clicking this button, the program
will start upgrading and enter the license file selection interface. For details, please refer to
Chapter 3.
6
www.raisecom.com User Manual
Enter the IP address of the host where the server of the NView NNM system will reside. All clients
will access the server using the specified IP address. Please click <Next> to enter the destination
location specification step.
7
www.raisecom.com User Manual
¾ “Install Data Base”: select this item, the program will install system default database
(mysql5.0) on the target host.
¾ “Choose Data Base”: The system supports 3 types of database currently (mysql 5.0 and
above versions, sqlserver 2000 and above versions, oracle 10g and above versions). After
selecting database type, relevant database parameters are required to be inputted. They are the
IP address of the server where the database reside, the port the database occupies, the user
name for logging on the database, the password for logging on the database, and the Oracle
database name if the database chosen is Oracle database.
After inputting all required parameters, please click <OK> to enter the step for confirming license
file.
The installation of NView NNM system requires a legal license file to be imported. Please click
<Browse…> to specify the location of the license file and click <Next> to enter the interface for
installation destination selection.
8
www.raisecom.com User Manual
The default installation destination for NView NNM system is “C:\Raisecon\NView\”. Click the
button <Browse…>, users can choose the location. After selecting the destination location, please
click <Next> to continue the installation.
Please make sure that the all the installation information is correct and click the button <Install> to
start the installation.
This process will copy the NView NNM programs on to the local hard disc. To quit the installation,
please click the button <Cancel>.
10
www.raisecom.com User Manual
Click the button <Finish> to complete the installation. The following three shortcut icons will appear
on the desktop when the installation process completes.
11
www.raisecom.com User Manual
Shortcuts will appear on the “Start” menu of Windows either (see Figure 2-14):
12
www.raisecom.com User Manual
This chapter mainly introduces the steps for upgrading NView NNM V4.2 to V5.0 using this
installation program. NView iEMS V2.0 can also be upgraded to NView NNM V5.0 using this
program and the steps are identical to the steps for upgrading NView NNM V4.0.
After setup language selection, please click <Next> to continue the installation.
13
www.raisecom.com User Manual
When process of copying installation files completes, the welcome interface will show up (see
Figure 3-3).
The content in the window shown in Figure 3-4 is a detailed description of the agreement concerning
network management software product of Raicecom. Please read with caution before installation. If
you accept the agreement totally, please click <Yes>, the system will enter the interface for
installation mode selection. In case of any disagreement towards some items or all items of the
agreement, please click <No> to quit the installation.
15
www.raisecom.com User Manual
Please click <Update NView NNM version to NView NNM V5.0> to enter the step for importing
license file.
16
www.raisecom.com User Manual
The installation of NView NNM system requires a legal license file to be imported. Please click
<Browse> to specify the location of the license file and click <Next> to enter the interface for
installation destination selection.
The default installation destination for NView NNM system is “C:\Raisecon\NView\”. Click the
button <Browse…>, users can choose the location. After selecting the destination location, please
click <Next> to continue the installation.
17
www.raisecom.com User Manual
Please make sure that the all the installation information is correct and click the button <Install> to
start the installation.
18
www.raisecom.com User Manual
Click the button <Finish> to complete the installation. The NView NNM V4.2 system is smoothly
upgraded to V5.0. Historical data, configuration information and EMS that have been installed
before will not change.
L Note: The upgrade is only designed for NView NNM V4.2 system installed following
“Typical Installation” process. For clients installed in distributed deployment scheme, users
have to uninstall the client before install the new client using NView NNM V5.0 installation
program. Please note that, after installing new NView NNM V5.0 client, installation of
corresponding EMS is required.
19
www.raisecom.com User Manual
Double-click the shortcut icon for starting the server on the desktop to start the server (see Figure
4-1).
After the startup, NView server will operate as a background service process. An icon will
appear on the system tray. Periodical flash of the icon indicates that the server is operating normally,
while no flash indicates the operating has been stopped. Right-click on the icon, a shortcut menu will
pop up as is shown below.
¾ ShutDown this Tool: The operation only close the icon on the tray and will not affect
20
www.raisecom.com User Manual
¾ Start the Server: This operation starts up the NView NNM server.
¾ Stop the Server: This operation closes down the NView NNM server.
¾ License Info: This operation opens the License management platform. Users can
browse License information on the platform.
Please input correct user name, password and management domain (Please refer to “system security
management” for instructions about management domain) information and click <OK>. The startup
manager will accomplish the remaining startup tasks. After these processes, the main view will turn
up, which indicates that the client has been started up successfully.
LNote: The default user name is “administrator”, and the default password is “raisecom”.
The default domain selection is “Default Domain”. Out of system security consideration,
immediate user information modification is strongly recommended. For the steps of modifying
user password, please refer to the relevant content in NView NNM V5.0 user manual.
21
www.raisecom.com User Manual
Input the user name and password of a user from the “admin” user group (For instructions
concerning user group, please refer to the instructions in “System Security Management” in NView
NNM V5.0 user manual.) and click the button <OK> to close down the server.
22
www.raisecom.com User Manual
5.1 Preparation
¾ Please make sure that the NView NNM system has been correctly installed on the target host
and the system is operating in order.
¾ Please ensure that the version of the current NNM system meets the lowest version
requirement of the EMS to be installed. Otherwise, please upgrade the current NNM system.
¾ If the current NNM system is operating, please quit the system (both the client and the server)
first, and make sure that the database service is running.
¾ If any personal network security software (e.g. Norton Internet Security) exists on the target
host, please stop it before the installation of the EMS and restart it when the installation
completes.
After copying the installation files, the welcome interface will turn up (see Figure 5-3).
23
www.raisecom.com User Manual
Click the button <Next> to continue. The installation program will check the operating environment
automatically. The process contains the following steps:
¾ The installation program will detect whether NView series platform exists on the host. If no
NView NNM system has been installed on the host, the confirm box as is shown in Figure
5-3 will pop up.
¾ The installation program will detect whether the existing NView platform meets the
requirement of the EMS to be installed. It the NView system can not meet the requirement of
the EMS, the prompt box as is shown in Figure 5-4 will pop up.
Figure 5-4 The prompt box to inform the existing NView NNM system need upgrade
Click the button <OK> to quit the installation. Users have to install the latest service pack and then
install the EMS.
¾ The installation program will check whether the version of current EMS is lower than the
version of the EMS to be installed. If the version of the existing EMS is higher than the
version of the EMS to be installed, the prompt box shown below will pop up.
24
www.raisecom.com User Manual
Figure 5-5 Prompt box to inform that the version of the EMS to be installed is lower than that of the existing
EMS
The content in the window shown in Figure 5-6 is a detailed description of the agreement concerning
network management software product of Raicecom. Please read with caution before installation. If
you accept the agreement totally, please click <Yes>, the system will enter the interface for
installation mode selection. In case of any disagreement towards some items or all items of the
agreement, please click <No> to quit the installation.
25
www.raisecom.com User Manual
After confirming the installation information, please click <Next> to start the installation.
The installation program will copy the programs of the EMS to local hard disc. To stop the
installation, please click the button <Cancel>.
26
www.raisecom.com User Manual
After the installation, please restart the NView NNM system to have the renewal take effect.
LNote: If the NNM system has deployed several clients, please install the EMS on the hosts
where clients reside following the instructions in this chapter.
27
www.raisecom.com User Manual
After selecting the language, please click <Next> to continue the uninstall process.
28
www.raisecom.com User Manual
Select “Remove”, and click <Next> to uninstall NView NNM system. After the uninstall, please
restart the computer.
29
www.raisecom.com User Manual
Chapter 7 FAQ
¾ Find “SNMP Trap Service” and double-click it, the property dialog box for SNMP Trap
Service will turn up.
30
www.raisecom.com User Manual
7.2 Alarms from network element devices can not reach the system.
To ensure that an alarm can be received and displayed by the system correctly, the following
conditions must be satisfied.
¾ Please make sure that all network devices under management and the management
workstation where the NNM system resides must be correctly connected to the network. And
the links between them are unblocked (devices can Ping each other and communication via
UDP protocol is allowed).
¾ The Port 162 of the host where the NNM system server resides must not be occupied by other
processes. For example, for Win2000 Server OS system, the SNMP Trap Service witch
occupies Port 162 is enabled by default. Before installing NNM system on this OS system,
the SNMP Trap Service must be stopped to release Port 162, otherwise, the NNM system will
not be able to receive alarm information. Please note that only the host where the server of
NNM system resides must satisfy this condition. For clients installed following distributed
installation scheme, they do not have to satisfy this condition.
¾ Communication via UDP protocol must be allowed on the network. In some specified
application environment, out of security consideration, all network devices are behind a
firewall. In this circumstance, please make sure that Trap is able to pass through the firewall
to reach the management work station. Otherwise, the system will not be able to receive
alarm information.
¾ The agent of the network devices must set the target of the trap to be the IP address of the
host on which the server of the NNM system resides.
¾ The NNM system should have the definition of the alarm type. Otherwise, even if the
information of the alarm is received, the system will regard it as an unknown alarm.
¾ Check whether the NNM system has set up any filter rules concerning the alarm type. If the
alarm is filtered by the system, the system will not display the alarm and even not handle it at
all.
¾ The host from which the alarm comes from should on the device list of the system. Otherwise,
the alarm information will be dropped by the system as alarm information from unknown
source.
¾ The host from which the alarm comes from should be a node in the management domain of
the current user. Otherwise, the alarm information will not be displayed (This will not affect
the receiving of the alarm information. But the information will not be displayed on the client
the administrator logged on.). There is no this restriction for users for “admin” user group.
31
www.raisecom.com User Manual
¾ The version of the EMS should match that of the device Agent program. For example, if the
version of Agent program is higher than that of the EMS, the information of some types of
alarms can not be received.
If all the conditions listed above are satisfied, the NNM system should be able to receive and resolve
alarm information correctly. Please note that the above conditions are the minimal set of conditions
that must be satisfied to have alarm information received correctly. In some specified application
environment, some other conditions may have to be satisfied.
7.3 Clients can not connect to the server after an installation following the
distributed scheme.
¾ Please check whether the server is started and operating in order.
¾ Please check whether the IP address of the host where the server resides is correctly inputted
when installing remote clients. During the startup process of the client, if the specified IP
address of the server can not be connected, the system will inform the user to enter the IP
address of the host where the server resides again.
¾ Please make sure whether the “User Access Control” function is enabled. If it is enabled,
please register the IP address of host where the remote client resides on the local clients,
otherwise, the remote client is not allowed to log on.
7.4 When starting the server, a dialog box that informs the failure of connecting
the database pops up.
The dialog box is shown below:
¾ Please confirm whether the database service is started. Please check whether the
“raisecom_database_engine” service is started via service management tools on the control
pane of Windows. If the service is not started, please start it manually.
¾ Existing firewall may block the access of the database. Please shut down the firewall or
configure the property of the firewall to have the database accessible.
¾ If the system uses MySQL database, please check whether MySQL has been attacked by
Worm virus. If MySQL has been attacked by the virus, please clear it using anti-virus
software.
7.5 When starting the EMS, the system informs communication timeout or SNMP
operation failure.
¾ Please check whether the main network management module of the device is operating in
order, whether the system signal indicator and Ethernet interface indicator are in normal
status, whether the network management card is correctly placed (For RC002 and RC004
chassis, the device should be plugged in the first slot of the chassis).
¾ Ping the IP address of the device node and check whether the node is route reachable.
¾ Check whether the version of the EMS matches that of the main network management
module of the device.
¾ Check whether the device type of the device node in the topology is consistent with the
32
www.raisecom.com User Manual