You are on page 1of 2

The multifunctional safety controller –

SafeC 200 / SafeC 400 entire safety monitoring in one device

... a wide variety of connection and

DATASHEET
application possibilities

ISO 9001: 2000

Features

• Safety controller for up to 10 safety devices • Adjustable stop delay time


• Safety category 4 PL e according to EN ISO 13849-1 or • Various safety components easily connected
SILCL 3 according to EN 62061 (SafeC 400) • Fixed and floating blanking configurable
• Safety category 2 PL d according to SILCL 2 (SafeC 200) • Optical interface for diagnosis and configuration
• Short response time • Numerous status outputs for connection to a PLC
• Relay or transistor output • Individually configurable
• Up to 8 contacts per controller module • Multi-purpose

Technical data

Electrical Relay outputs


Power supply UN +24 VDC ± 20 % (IEC 60204-1) Number of contacts Block A: 3 NO contacts
at 5% residual ripple 0.85 ... 1.15 UN Block B: 5 NO contacts
Current consumption max. 500 mA (without load) Response times
Inrush current max. 1.7 A / 10 ms – Light curtain ≤ 32 ms
Max. power consumption 15 W at max. supply voltage – Safety switch ≤ 96 ms
Fuse protection 5 A (slow fuse) Contact type Relay, force guide
Outputs Two separate safety blocks – Max. switching capacity 1,150 VA / 120 W
(optional up to 8 NO contacts or – Max. switching current 5A
4 PNP) – Max. switching voltage AC 230 / 240 V, DC 300 V

Mechanical PNP outputs (short circuit monitoring)


Dimensions 122 x 105 x135 mm (with plugs) Status outputs
Quick mounting Top hat rail 35 mm (EN 50022) – Voltage (terminals L1-L16) +24 VDC ± 20%
Installation position No restrictions – Output current max. 30 mA
Enclosure rating IP20 (housing and terminals) Safety outputs 4 P (cross-fault detection)
Temperature range Operation: 0 ... +55°C – Voltage +24 VDC ± 20 %
Storage: –25 ... +70°C – Output current max. 400 mA
Response time with UN protective mode ≤ 25 ms
Relative humidity 15 ... 95 % non-condensing

General
Safety category 4 PL e acc. to EN ISO 13849-1 or
SILCL 3 acc. to EN 62061
2 PL d acc. to EN ISO 13849-1 or
SILCL 2 acc. to EN 62061
Approvals CE, TÜV, CSA, UL
Interfaces RS 485 / OptiLink (optical)
Dimensions SafeC 200 / SafeC400

104

105
Block A
94

95
84

85
74

75

135
64

65

55
54

Block B

45
44

35
34

25
24

15
12
14

2
B: FSD FSD : A
B: Response delayed Response delayed: A
105
S40 S38 S36 S35 S37 S39

L11
L16
S13 S15 S16 S14

Block B Block A
stop switch
Emergency

(All dimensions in mm)

L10
L15

15 10 Safety switch 1
L14

14 9 L9
L12 S28 L13

L8

13 8
+24V

L7

3
L3

Int
Prevention
+24V

L6
S10

12 SP
Prevention

Blanking
Safety
RSA RSB S20 S18 S17 S19
S23 S22 S24 S26

S34 S32 S31 S33 S41 S44


L2

Safe4 2 23

Block B
S11 S12

Safe4 19 22
EDM
Start

Block A
18 21
EDM
Safety switch 2

20
L1

1
Res S21

5 RS485
0V
0V

17
Power

+24V
+24V

P 4 RS485

R E

Receiver Safe400

Programming using the OptiLink


Emitter Safe400 ­interface

Ordering information
Controllers
Art. Nr. Typ Description

103 562 configurations


Special SafeC 400 3C CAG A001
on request Controller with 1× 3 relay contacts
090310 Part. no. 001 144 en

103 564 SafeC 400 8C CAG A001 Controller with 1× 3 and 1× 5 relay contacts
103 561 SafeC 400 4P CAG A001 Controller with 2 × 2 PNP outputs

Special configurations available on request.

CEDES Safety & Automation AG  •  ( + 41 81 307 8200  •  Fax + 41 81 307 8201  •  E-mail: csa@cedes.com  •  www.cedes.com
CEDES Safety & Automation AG reserves the right to modify or change technical data without prior notice.
Copyright © 2008 Rockwell Automation, Inc. All rights reserved.

You might also like