Galvafroid constructive solutions

Zinc rich cold galvanising coating

Uses Application Instructions

To provide a galvanic protection on iron and steel. It can be Preparation


used as a self-finish or as a durable rust inhibiting primer
beneath selected top coats. It is recommended for the All ferrous surfaces should be clean and free from oil,
protection of structural steelworks, agricultural and grease mill scale, rust and existing coatings. This is best
construction plant and machinery, gates, railings, iron, pipe- achieved by grit blasting, although thorough wire brushing
work and guttering, and the rust prevention of in-situ welding can be sufficient. Some rust removers based on phosphoric
work. acid tend to leave an electrically insulating film on ferrous
metals and must not be used.
Advantages
Mixing
 Protects ferrous metals Galvafroid must be thoroughly stirred to give a uniform
 Suitable as a primer or self-finish product prior to application. It is recommended that the
 Prevents rust creep contents are stirred periodically during application to avoid
 Easily applied by brush or roller settlement.

Galvafroid is supplied at the correct consistency for direct


Description application from the tin but, should it be found necessary to
thin, only Fosroc Solvent 102 should be added, at a rate
Galvafroid zinc rich coating is formulated as an easily not exceeding 1 litre of thinners to 8 litres of Galvafroid.
applied, cold galvanising protection against corrosion on all
ferrous metals. Galvafroid has a mid-grey, matt finish. Application

Technical support In order to obtain the protective properties of Galvafroid, it is


important that the correct rate of application is achieved.
Fosroc offers a comprehensive range of high performance,
Number of coats: 1 or 2
high quality repair, maintenance and construction products.
In addition, Fosroc offers a technical support service to o
specifiers, end-users and contractors, as well as on-site The minimum application temperature is 5 C.
technical assistance.
All prepared surfaces should be treated with one or more
coats of Galvafroid. The material should be liberally applied
Design criteria without any attempt to brush or roll out. The required
thickness of coating may be built up by successive
Galvafroid should be applied in two coats when employed as applications of Galvafroid when the previous coat is
a self-finish and one coat when used as a primer. To achieve completely dry.
the correct protection, Galvafroid must be applied on the
substrate at the coverage recommended. Over-coating

Properties Although usable as a self-finish, it is recommended that


Galvafroid be overcoated to protect from mechanical
damage and chemical attack outside pH 5-9.
Volume solids: 40%
Solids by weight: 80% It is recommended that the Galvafroid coating be allowed to
Zinc content by volume on dry film: 61% weather for at least 3 days before proceeding. Overcoating
Zinc content by weight on dry film: 90% should take place with a non-saponifiable material, such as
o
Drying times at 20 C a solvent-based acrylic or chlorinated rubber material.
touch dry: 2 hours Cellulose, bituminous, alkyd and water-based coatings are
hard dry: 24 hours not suitable.
recoating time: 24 hours min
Cleaning
Specification clause
Galvafroid should be removed from tools and equipment
with Fosroc Solvent 102 immediately after use. Dried
The anti-corrosive primer shall be Galvafroid, a zinc rich
material can only be removed mechanically.
material specifically designed to provide a rust inhibiting
protection to ferrous metalwork.

Page 1
Galvafroid
Limitations additional skin protection. In case of contact with skin, rinse
with plenty of clean water, then cleanse with soap and
Galvafroid is formulated for application to clean ferrous water. Do not use Solvent. In case of contact with eyes,
substrates and should not be used on rust, corroded rinse immediately with plenty of clean water and seek
surfaces. medical advice. If swallowed, seek medical attention
immediately - do not induce vomiting.
Galvafroid should not be applied over existing coatings.
Fire
Galvafroid should not be used on surfaces in contact with
drinking water. Galvafroid and Fosroc Solvent 102 are flammable. Keep
away from sources of ignition. No smoking. In the event of
Galvafroid should not be used on surfaces exposed to soft fire, extinguish with CO 2 or foam. Do not use a water jet.
o
water at temperatures above 60 C.
Flash points
Galvafroid should not be used on surfaces treated with o
phosphoric acid based rust removers. Galvafroid: 41 C
o
Fosroc Solvent 102: 33 C
Galvafroid should not be overcoated with materials
containing strong solvent such as chlorinated and aromatic For further information, refer to the Product Safety Data
hydrocarbons, esters and ethers. Sheet.

Estimating Additional Information

Supply Fosroc manufactures a wide range of complementary


products which include:
Galvafroid: 0.8 / 1.9 litre tins
 Waterproofing membranes & waterstops
Fosroc Solvent 102: 4 / 25 litre tins
 Joint sealants & filler boards
Coverage
 Cementitious & epoxy grouts
2
Galvafroid: 16m /litre/ when used as a  Specialized flooring materials
2
primer. 8m /litre when used as a
self-finish (2 coats) Fosroc additionally offers a comprehensive package of
products specifically designed for the repair and
refurbishment of damaged concrete. Fosroc’s ‘Systematic
Storage
Approach’ to concrete repair features the following:
Galvafroid has a shelf life of 12 months if kept in a dry store  hand-placed repair mortars
o
below 25 C in the original, unopened container.
 spray grade repair mortars
Precautions  fluid micro-concretes

Health and safety  chemically resistant epoxy mortars


 anti-carbonation/anti-chloride protective coatings
Galvafroid and Fosroc Solvent 102 should not come in
contact with the skin and eyes or be swallowed. Ensure  chemical and abrasion resistant coatings
adequate ventilation and avoid inhalation of vapours. Some For further information on any of the above, please consult
people are sensitive to resins, hardeners and solvents. your local Fosroc office - as below.
Wear suitable gloves and eye protection. If working in a
confined area, suitable respiratory protective equipment
must be used. The use of barrier creams provides

Important note:
Fosroc products are guaranteed against defective materials and manufacture and are sold subject to its standard Conditions
for the Supply of Goods and Services, copies of which may be obtained on request. Whilst Fosroc endeavours to ensure that
any advice, recommendation, specification of information it may give is accurate and correct, it cannot, because it has no direct
or continuous control over where or how its products are applied, accept any liability either directly or indirectly arising from the
use of its products, whether or not in accordance with any advice, specification, recommendation of information given by it.

Fosam Company Limited


Head Office Telephone: +966 2 637 5345 Fax: +966 2 637 5891 email: fosam@fosroc.com
Post Box 11081 Regional Offices
Jeddah – 21453 Jeddah Sales Office Tel: (02) 608 0999 Fax: (02) 638 0693 Yanbu Tel: (04) 322 4280 Fax: (04) 391 2980
Jeddah Showroom Tel: (02) 665 0187 Fax: (02) 667 4844 Makkah Tel: (02) 542 0869 Fax: (02) 542 0869
Saudi Arabia Riyadh Tel: (01) 482 9303 Fax: (01) 482 7562 Medinah Tel: (04) 855 0091 Fax: (04) 855 0047
Dammam Tel: (03) 814 1282 Fax: (03) 814 1581 Jubail Tel: (03) 362 3904 Fax: (03) 362 3875
www.fosroc.com Khamis Mushayt Tel: (07) 250 0469 Fax: (07) 250 0469 CSD Tel: (02) 608 0999 Fax: (02) 638 0693

Registered Office: Industrial Area, Phase 4, Road No. 414, Street No. 407
Page 2 FO SA/GALVAFROID/05/A

You might also like