SCHEDULE OF COLUMN

NO. OF CONCRETE SIZE REINFORCEMENT


S. NO. DESIGNATION COLUMN GRADE OF SKETCH TIES
LATERAL TIES
COLUMN LONGITUDENAL MIDDLE ZONE END ZONE BEAM

1- C1 20 25 300 X 300 4-16Ø 8Ø@150 C/C 8Ø@100 C/C

300
Six Legged Six Legged
Stirrups Stirrups
TIES T1

300

2- C2 1 25 300 X 300 8-16Ø 8Ø@150 C/C 8Ø@100 C/C

300
Six Legged Six Legged
Stirrups Stirrups TIES T1 COLUMN
TIES T3

300
TIES T2

3- C3 3 25 300 X 300 4-20Ø 8Ø@150 C/C 8Ø@100 C/C PLINTH BEAM

300
Six Legged Six Legged
Stirrups Stirrups
TIES T1

300

TIES
4- C4 1 25 300 X 300 4-25Ø 8Ø@150 C/C 8Ø@100 C/C

300
TOP OF SPECIAL CONFINING REINFORCEMENT
Six Legged Six Legged 300 mm (SPACING AND DIA OF
THE FOOTING REINFORCEMENT SAME AS IN (h+z))
Stirrups Stirrups
TIES T1 TIES SAME AS
IN (H - 2h)
300
Ld Ld

300Min. 300Min.

5- C5 1 25 300 X 300 8-12Ø 8Ø@150 C/C 8Ø@100 C/C

300
TIE SPACING DETAILS FOR COLS( SECT X-X)
Six Legged Six Legged (FOR ALL TYPE OF FOOTINGS)
Stirrups Stirrups TIES T1
TIES T3 h = H/6 OR d OR 450mm
WHICHEVER IS MORE
300 d = LARGER COL DIMENSION
TIES T2

A B C D E F

8'-1" 5'-9" 3'-7" 7'-10" 13'-10"

1 1
5'-5"

2 2
11'-9"

3 3
6'-8"

4 4
4'

5 5
3'-5"

6 6
6'-11"

7 7
6'

8 8
COLUMN PLAN

A B C D E F