Sample collected must truly represent the conditions prevailing inside the
stack.
Traverse Point:
Stack sampling is carried out by diverting a part of the gas stream through a
sampling “train” of which a general arrangement is shown in fig.
The train consists of a nozzle placed in the gas stream, a sampling probe
through which the sample is drawn at different traverses, particulate and gas
collection devices, a flow measuring device and a prime mover such as a
vacuum pump or an ejector.
Nozzle: It is at the end of the probe is sharp edged, pointing inward from the
outside edge and the traversing probe is made of stainless steel with glass or
Teflon lining.
For Sampling hot gases whose temperature are above 400 0C, these probes
are provided with a circulating coolant system to prevent combustion of
particulate materials inside the probe and to prevent the temperature from
exceeding the maximum allowable temperature of filtration materials.
Flow measurement: Use rotameter or orifice meter or dry gas meter if the
information on the total volume of the gas sampled is required.
Normally placed after the collection devices and upstream of a vacuum
pump so that any leak in the vacuum pump will not cause errors in the gas
volume measurements
Particulate sampling:
Isokinetic Conditions:
(1) By calculating the point velocity of the free stream with a pitot tube
located as near to the sampling probe as possible without interfering
with the free stream and then adjusting the sampling velocity.
Rapid adjustment of sampling rate is required; Pitot tube readings and stack
temperatures are converted to equivalent orifice pressure differentials to
maintain isokinetic sampling velocities.
In this the static pressure measured between the inner and outer probe walls
is balanced.
This assumes that the velocity within the probe is equal to the free stream
velocity.
Conduct calibration over the test range.
Determination of gas composition:
Where
Mx = Molecular weight of CO2, O2 and CO and N2 (44, 32, 28 and 28
respectively) and
Bx represent % of gases
The moisture content in the stack may be determined by any one of the
following methods:
Determination of Temperature:
The temperature probe is inserted into the stack and the readings are taken
with the help of a pyrometer.
Sample recovery:
After cooling, the outside of probe assembly is cleaned with cotton waste.
Disconnect the nozzle.
Remove the thimble and keep it in a clean glass beaker.
The particulate matter adhered to the inside walls of he nozzle, should be
transferred carefully to the thimble.
Weigh the thimble with sample (W2).
The difference in weight (W2 - W1) will give the particulate collected