You are on page 1of 5

Design of Bolted Gusset base OF COLUMN( FOR HEAVELY LOADED COLUMS)

Material properties
Ultimate strength fu = 410
Ultimate strength of bolt fub 400
yield strength fy = 250
grade of concrete = 15
Bearing strength of concrete = 6.75
Partial safety factory gm0 = 1.1
Properties of beam section TYPE(ADOPTED) = 661.2
ISHB300
Depth of section D = 350
Width of flange bf = 250
Thickness of flange tf = 11.6
Thickness of web tw = 8.3
Grade of bolts 4.6 fub = 400
Partial safety factory gmb = 1.25
Elastic modulus ze =
Plastic modulus zp =
Diameter bolts d = 24
Diameter bolts hole do = 26
No shear planes intercepting threads nn = 1
No shear planes non intercepting threads ns = 0
Bolt details
Gross Area oF Bolt Asb = 452.448

Net Area oF Bolt Anb = 352.90944

Pitch of bolts P = 60

Edge distance of bolt e 39


Factored load PL = 1700
Required area of base plate Ab = 251851.852

Assumed thickness of gusset plate = 16


height = 150
Angles selected ISA 150x115x15 width = 115
thickness = 15
Minimum width required 612
provided width = 620
Projection of base plate beyond flange angle toe 4
Length of base plate 411.5
provided length = 420

provide a base plate of size 620 X 420 = 260400

The bearing pressure of concrete w=P/A1 = 6.52841782

Hence safe

Critical section of base for bolted gusset base will be at section x-x

Length of base plate acting of acting as cantilever c1 = 104

Maximum Moment Mx wc12/2 = 35305.68

(thickness obtained) by combined moment of t = 27.87


base plate and angle

Actual Thickness of slab base t = 11.870

Hence safe

Shear capacity of bolt(Vdsb) = 65200.7553

Kb 0.769 0.519 0.976 1

0.519

Bearing capacity of bolts (Vdpb) = 159507.692

No of bolts Obtained = 13.0366588

No of bolts provided = 14

Gusset plate details

Height of gusset plate =


length of guset plate =
*check for top edge buckling of column FINAL CHECK
OLUMS)

N/mm2
N/mm2
N/mm2
N/mm2
N/mm2

N/mm2

mm
FROM
mm STEEL
TABLES
mm
mm
Mpa

IF REQUIRED IN DESIGN

mm
mm

mm2

mm2

mm

mm
kN
mm2

mm
mm
mm
mm
mm
mm
mm
mm

mm2

N/mm2

mm

Nmm

mm

mm

N IS 800:2007 CLAUSE 10.3.3

least of the values adopted

IS 800:2007 CLAUSE 10.3.4

Assuming 50%
of total load
passes through
connections

find based no of bolts