You are on page 1of 3

POWERMINE™ MINING-CABLE SV-AT

———————
(N)TMCGEH3S 6/10 kV 2605 B
3 x 120 + 2 x 50E + 1 x 10P

This specification covers the construction requirements for type POWERMINE (N)TMCGEH3S cables
rated for use at 10 (Um 12) kVand conductor temperatures up to 90 °C.

1 Application
Heavy duty portable power cable for rough use with mobile mining equipment, such as shuttle cars,
continuous miners, cutting or loading machines, conveyors, drills or pumps in wet or dry locations. For
three-phase AC where selfcontaining grounding conductor as well as a ground monitoring conductor is
required. Specially designed for reeling applications.

2 Standards
In line with:
DIN VDE 0250 part 813: Cables, wires and flexible cords for power installation – Trailing cable
DIN EN / IEC 60228: Conductor flexible rope-lay stranded
DIN VDE 0207 part 20: Insulating and sheathing compounds for cables and flexible cords:
Rubber sheath compounds

3 Design

C
A
B
D

Power cores ( A)
Conductor: Flexible, stranded, tinned annealed copper acc. to DIN EN/IEC 60228 class 5
Insulation: triple extrusion:
- inner semi-conductive stress control layer,
- elastomeric insulation made of dielectric and thermal high graded, ozone-
resistant ethylene-propylene-rubber (EPR), compound 3GJ3 acc. to DIN
VDE 0207 part 20
- outer semi-conductive insulation shield layer, easy strip (Thermostrip)
all three covers are applied and cross-linked in one process;
Screen: Mixed braid with tinned copper wires and synthetic threads,
colour code: black, white, red

Bare grounding conductors (B)


Conductor: Flexible, stranded, tinned, annealed copper in accordance to DIN EN/IEC 60228 class 5
Issued: ML-I PM,
Hamacher page 1 / 3
c
SV-AT
———————
2605 B 13.10.14, page: 2 of 3

Ground check conductor (pilot) (C)


Conductor: Flexible, stranded, tinned, annealed copper acc. to DIN EN/IEC 60228 class 5
Insulation: Thermoplastic polyester elastomer (TPE-E) Hytrel 4056 *), Colour code: yellow

*) Hytrel® is the DuPont registered trademark for its brand of thermoplastic polyester
elastomers. The polyether-ester block copolymers combine many of the most desirable
characteristics of high-performance elastomers and flexible plastics. Hytrel® offers a
unique combination of mechanical, physical, and chemical properties that qualifies it for
demanding applications. The various grades of Hytrel® exhibit a wide range of
flexibility/stiffness and processing capabilities.

Stranding The three phase conductors are stranded with two grounding and the ground check
conductor in the interstices with a left hand lay.

Jacket (D) Polyether-based thermoplastic polyurethane (TPU), abrasion and impact resistant, good
elastic recovery, tear and kick-resistant, oil and grease resistant, hydrolytic stabil,
colour: orange, marking: POWERMINE™ RHEYFIRM (N)TMCGEH3S
3x120+2x50E+1x10P 6/10 kV year I NEXANS I

4 Operation conditions
4.1 Temperatures
operating temperature of the conductor: ≤ 90 °C
short-circuit temperature of conductor: ≤ 200 °C
4.2 Tensile loads
short time for installing fixed laying: 50 N/mm²
permissible permanent pulling force
static: 15 N/mm²
dynamic: 25 N/mm²
(referred to the cross-section of the
phase conductor)
4.3 Bending radius
min. bending radius for fixed installation: 4xD
free bending (on drum): ≥ 7.5 x D D = outer-∅ [mm]

5 Tests
In accordance with: - general: DIN VDE 0250 part 1
- conductor resistance: DIN EN / IEC 60228 class 5
- all other tests: DIN VDE 0250 part 813 Tab. 4
Test voltage 17 kV AC, 42.5 kV DC
SV-AT
———————
2605 B 13.10.14, page: 3 of 3

6 Technical data
Type-no.: 7127xxxx
Size Power conductor [mm²] 120
Resistance at 20 °C [Ω/km] 0.164
Size grounding conductor [mm²] 50
Resistance at 20 °C [Ω/km] 0.393
Size ground check conductor [mm²] 10
Resistance at 20 °C [Ω/km] 1.95
Weight approx. [kg/km] 7200
Outer diameter [mm] 62 - 66
Colour: OR
Short circuit current
(80 – 200 °C/1 s) [kA] 15.4
(80 – 200 °C/0,5 s) [kA] 21.7
Current-carrying capacity [A]
at 30 °C ambient temperature on ground: 352

Conversion factors for current-carrying capacity at ambient temperature deviated from 30 °C


(80 °C at conductor):

Ambient temperature [°C] Multiplying correction


factors
10 1.15
20 1.08
30 1.00
40 0.91
50 0.82
60 0.71
70 0.58