COPYRIGHT AND RIGHT OF REPRODUCTION OF THIS DRAWING

OR ANY PORTION THEREOF IS RESERVED BY THE ARCHITECTS


H9 H10 HSC03 H9 H10 H9 H10
H9 H10
HOT-2-001-00 CLIENT REPRESENTATIVE /
CLIENT :
DEVELOPMENT MANAGER:
5425
2725 2500 2725 2500 TAKATUF GEMSTONE
5225 400 200 200 5025

70
7

7
HD HD HD HD

200 150

150

150

150
200

200

200
600

EQ.
SOP SOP SOP

1550
GENERAL NOTES

1350
S O S O S O E2 1. ALL STRUCTURAL, MEP, CIVIL AND LANDSCAPING QUERIES ARE TO BE

L2 L2 L2 L2 L2 L2 L2 L2 REFERRED TO THE RELEVANT CONSULTANT DRAWINGS, SPECIFICATIONS AND


1975

1975

1975

1975

1975
DETAILS
2925

2925

2925
2775
2. ALL DESIGN AND CONSTRUCTION TO COMPLY WITH APPLICABLE REGULATIONS AND
HOUSE LOCAL AUTHORITY REQUIREMENTS
E1 C02
AFL:2400 E1 KEEPING
H05-204
E1 C05 GSM ROOM
3. CONTRACTORS AND SUBCONTRACTORS ARE TO CHECK ALL DIMENSIONS AND
LEVELS ON THE BUILDING SITE BEFORE COMMENCING WITH ANY WORK
4. ANY DISCREPANCY IN THE DRAWINGS, DIMENSIONS & SPECIFICATIONS ARE TO BE
U/S H20-403 BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO ANY WORK

3960
BUTLER CLEAN SOP STAFF BEING PUT IN HAND
PANTRY ROOM 5. ONLY FIGURED DIMENSIONS TO BE FOLLOWED - SCALED DIMENSIONS OF
TOILET
100

100

100

100
H03-204 DRAWINGS WILL NOT BE PERMITTED
H01-204 H05-205 6. FOR GENERAL NOTES REFER TO SHEET NUMBER AR-GEN-0-002-00
LINEN CHUTE

2250
2050
HRS06
HE HE HE HE KEY PLAN:

D1 L2
1325

1325

1325

1685
10
L2 L2
825

L2
Q

LINEN CHUTE LINEN CHUTE LINEN CHUTE HOT-4-206-00

1185

1185
1185
EQ.
2350 N
HRS06 HRS06 HRS06

200
200 1300 100 2350 100 1175 400 200 1300 100 3625 400 RES HOT
200 1300 100 3625 400 200 1300 100 3625 400
2725 2900 2725 2900 200 2725 2900
2725 2900
5825

POD
BUTLER PANTRY ENLARGED RCP PLAN - BOH CLEAN ROOM ENLARGED RCP PLAN - BOH1 HOUSEKEEPING ENLARGED RCP PLAN - BOH GSM ENLARGED RCP PLAN - BOH
2 4 6 8
1 : 50 1 : 50 1 : 50 1 : 50
NOTE: COORDINATES SHOWN ARE AS PER NGN (NATIONAL
GEODETIC NETWORK) DATUM OF SAUDI ARABIA.

H9 H10 F10/350.03 - F10/350.03 -


H9 H10
F10/350.03 -
200MM THICK SOLID CONCRETE H9 H10 H9 H10 200MM THICK SOLID CONCRETE 200MM THICK SOLID CONCRETE Rev. No.
O
Date
04/05/2017
By
JD ISSUED FOR CONSTRUCTION
Description Resp. Consult
DSA
200 5025 BLOCKWORK. BLOCKWORK. BLOCKWORK.
5225 2725 2500
100 2625 1300 1100 100 5225 400
100 2625 1300 1100 100
HD HD HD HD
150

200 150

200 150

150
H01-203D
H05-203D
200

200
H03-203C H20-203D

FALL
DRAWER

1550
E30.02 - E30.02 - E30.02 -

FALL
E30.02 -

1350
BUTLER REINFORCED CAST IN SITU CONCRETE REINFORCED CAST IN SITU CONCRETE REINFORCED CAST IN SITU CONCRETE
REINFORCED CAST IN SITU CONCRETE

2175
PANTRY SHEAR WALL TO STRUCTURAL CLEAN SHEAR WALL TO STRUCTURAL 00-01 - SHEAR WALL TO STRUCTURAL
SHEAR WALL TO STRUCTURAL
1975

1975

1975
FALL FALL ENGINEERS DETAILS AND SPECIFICATION. ROOM FFL +46.25
ENGINEERS DETAILS AND SPECIFICATION. SEE DRAWING SERIES 12128-HOT-5-101-00 H05-205A ENGINEERS DETAILS AND SPECIFICATION.
2925

2925

2925

2925
H01-204 TOC +46.15 ENGINEERS DETAILS AND SPECIFICATION.
H03-204 FOR BOH FINISHES SCHEDULE
FFL +38.65 GSM ROOM FFL +110.85

100
00-01 - HOUSE
3800

TOC +38.55 FFL +53.85 TOC +110.75


F10/350.01 - F10/350.01 - F10/350.01 - KEEPING F10/350.01 - H20-403
SEE DRAWING SERIES 12128-HOT-5-101-00 TOC +53.75 FFL +53.85

3800
100MM THICK SOLID CONCRETE 00-01 - 100MM THICK SOLID CONCRETE FOR BOH FINISHES SCHEDULE 100MM THICK SOLID CONCRETE H05-204 TOC +53.75 100MM THICK SOLID CONCRETE
BLOCKWORK. SEE DRAWING SERIES 12128-HOT-5-101-00 BLOCKWORK. BLOCKWORK. BLOCKWORK.

FALL
00-01 -
100

100

100

100
FOR BOH FINISHES SCHEDULE FALL FALL SEE DRAWING SERIES 12128-HOT-5-101-00
LINEN CHUTE
FALL FOR BOH FINISHES SCHEDULE
FALL

STAFF HRS06

1950

2250
TOILET
HE HE HE H05-205
HE
1325

1325

1325

1525
LINEN CHUTE FALL 9

825
HRS06
ANGLE LEDGE

400
1025

1025
LINEN CHUTE
WITH
PROTECTIVE COVER

1300 3625 LINEN CHUTE HOT-4-206-00


HRS06 HRS06
200

200
160
1300 100 3625 400 F10/350.03 - F10/350.03 - 1500 100 2350 100 1175 400 400 1300 100 3625 400 F10/350.03 -
F10/350.03 -
5 200MM THICK SOLID CONCRETE 200MM THICK SOLID CONCRETE 200MM THICK SOLID CONCRETE
2725 2900 2725 2900 200MM THICK SOLID CONCRETE 200 2725 2900
BLOCKWORK. BLOCKWORK. BLOCKWORK.
AR-GEN-4-050-06 BLOCKWORK.
H42.02 - H42.02 - 5825 H42.02 -
PRECAST CONCRETE PANEL CLADDING PRECAST CONCRETE PANEL CLADDING H42.02 - PRECAST CONCRETE PANEL CLADDING
SYSTEM TO FACADE CONSULTANTS SYSTEM TO FACADE CONSULTANTS PRECAST CONCRETE PANEL CLADDING SYSTEM TO FACADE CONSULTANTS
DETAILS AND SPECIFICATION. DETAILS AND SPECIFICATION. SYSTEM TO FACADE CONSULTANTS DETAILS AND SPECIFICATION.
BUTLER PANTRY ENLARGED PLAN - BOH CLEAN ROOM ENLARGED PLAN - BOH HOUSEKEEPING ENLARGED PLAN - BOH DETAILS AND SPECIFICATION.
GSM ROOM ENLARGED PLAN - BOH
1 3 5 7
1 : 50 LVL H01, H04, H07, H11, H14, H17 1 : 50 LVL H03, H06, H09, H13, H16, H19 1 : 50 LVL H02, H05, H08, H12, H15, H18 1 : 50 LVL H10, H20, H21
CEILING LEGEND

ID
CEILING BY INTERIOR DESIGN
AFL: XXXX
INDICATES HEIGHT ABOVE FINISHED
FLOOR LEVEL

CXX
INDICATES CEILING TYPE
AFL: XXXX
INDICATES HEIGHT ABOVE FINISHED
HOTEL CEILING FIXTURE LEGEND FLOOR LEVEL

TYPE SYMBOL DESCRIPTION TYPE SYMBOL DESCRIPTION CXX


INDICATES CEILING TYPE
Ceiling recessed fixed downlight with wide
HE RI-01
beam optics- RAL to match ceiling finish
Wall recessed lighting fixture, night light
RC-01 Ceiling recessed narrow beam directional downlight U/S
INDICATES UNDERSIDE SLAB
RI-02 RC-02 Ceiling recessed downlight with narrow beam optics
toilet cubicle/ bedroom
RI-03 Furniture integrated short pitch LED profile/night light RC-03 Ceiling recessed directional downlight with medium beam
2410 connected to sensors or switch - bedside tables optics-RAL to match ceiling finish
ST5 ST6 Integrated linear LED IP rated, night light Ceiling recessed adjustable downlight with wide beam optics
RI-04 RC-04
- under vanity
HOT-4-206-00 HOT-4-206-00 1185 1225 Ceiling recessed fixed downlight with wide beam optics IP rated Decorative pendant. As per interior designer's specification. C01 - SUSPENDED MODULAR CEILING - 600x600 MM
WL01 RI-05
- bathroom/pantry
FF&E-06
1675 Ceiling recessed directional downlight with wide
160 200 1950 100 RI-06 FF&E-07 OMITTED
beam optics IP 65
1675 100 1175 400 RI-07
Ceiling Recessed fixed Downlight with narrow
beam optics IP rated - above vanity * Final Location, Wattage and size of FF&E lights Refer to KCA'S package C02 - SUSPENDED MODULAR CEILING MOISTURE
RI-09 Linear LED profile at integrated in ceiling coves and ceiling RESISTANT - 600x600 MM
100 175 900 100 400 feature
Ceiling recessed adjustable downlight with wide beam
F10/350.01 - RI-10
optics - RAL to match ceiling finish
100MM THICK SOLID CONCRETE TH04 RI-14 Flexible side emitting LED strip
cove light IP 68 - above bathtub C03 - GYPSUM BOARD
BLOCKWORK. F10/350.03 - RI-16 Linear LED profile at cove IP 67 - bathroom
WL01 Typical decorative table lamp, as per interior designer's
200MM THICK SOLID CONCRETE CEILING CEILING Recessed LED profile
FF&E-01
specification-bedside table
RI-17
100

H05-205A BLOCKWORK. VOID VOID covered with diffuser by contractor Typical decorative table lamp, as per interior designer's
FF&E-02
WL01 RI-18 Shelf integrated downlight at shelf unit
specification - desk C04 - GYPSUM BOARD - MOISTURE
E30.02 - FF&E-03
Decorative floor lamp, as per interior designer's
REINFORCED CAST IN SITU CONCRETE F10/350.01 - E30.02 - RI-19 Ceiling recessed fixed downlight with wide beam specification - bedroom
235 optics IP 67 - shower Wall Sconce, as per interior designer's
300 REINFORCED CAST IN SITU CONCRETE
300

FF&E-04
SHEAR WALL TO STRUCTURAL 100MM THICK SOLID CONCRETE SMOOTH FACED VINYL CLAD PLASTERBOARD RI-20 Ceiling recessed fixed downlight with Narrow specification - vanity
SHEAR WALL TO STRUCTURAL beam optics Surface mounted reading light, as per interior
FA

WL01 ENGINEERS DETAILS AND SPECIFICATION. BLOCKWORK. LAY-IN ACOUSTIC AND MOISTURE RESISTANT FF&E-05
designer's specification - bedhead C05 - PAINTED RENDER UNDERSIDE OF SLAB
LL

SOP MODULAR CEILING WITH POWDER COATED SOP ENGINEERS DETAILS AND SPECIFICATION. RI-21 Wall recessed LED light IP rated
Typical decorative pendant / chandelier, as per interior
SOP FF&E-06
designer's specification
LINTEL SUSPENSION SYSTEM - SIZE 600 X 600 MM
Furniture integrated LED profile

100
H42.02 - RI-22
FF&E-07 omitted
PRECAST CONCRETE PANEL CLADDING -COLOUR WHITE - RI-23 LED light strip for backlighting ceiling screens
FFL +53.85 ARMSTRONG OR SIMILAR APPROVED Integrated linear light fixture,as per interior designer's C06 - RECLAIMED WOOD (FOR SOFFIT)
PU25 SYSTEM TO FACADE CONSULTANTS 300
FF&E-08
specification - Wardrobe shelves
1225

TOC +53.75 300 Furniture integrated profile, as per interior designer's


DETAILS AND SPECIFICATION. FF&E-09
specification - furniture
H05-205A Furniture integrated recessed downlight with wide
FF&E-10 beam optics downlight - wooden rack, as per interior
PU40
FALL

designer's specification C07 - EMULSION PAINT - LOW VOC ANTI FUNGAL


Typical decorative pendant, as per interior
FF&E-11
designer's specification - entrance
ST7 AC 08 H05-205A
FF&E-12 Backlit Mirror
HOT-4-206-00 C08 - ANTI CARBONATION PAINT
AC 08 FF&E-13 Backlit Mirror
STAFF WL03
1950

FF&E-14 Backlit Mirror


2410

TOILET PU25 Typical decorative floor lamp, as per interior designer's


FF&E-15
H05-205 PU25 specification
C09 - EXTERNAL FIBRE CEMENT BOARD
HE 2700 F10/350.01 -

2700

2700
2700
* Final Location, Wattage and size of FF&E lights Refer to KCA'S package
PU19 100MM THICK SOLID CONCRETE
STAFF
450 TOILET BLOCKWORK.
PU23 ID - CEILING BY ID
ST8 H05-205
HOT-4-206-00
PU24-A PU24-A
M10/112 -
LIGHTING EMERGENCY LIGHTING
2100

2100
FALL STAFF
UNBONDED SAND CEMENT SCREED LAID TOILET LED EMERGENCY LIGHT FIXTURE (CEILING / SURFACE
E1
825

TO MINIMUM FALLS 1:100 OVER H05-205 F1


MOUNTED IP20 - REFER TO THE LIGHTING SCHEDULE NOTE: FRONT OF HOUSE CEILING LAYOUTS & LEVELS SHOWN ARE
PU22 PU16-A SURFACE MOUNTED 2x28W T16
INDICATIVE; REFER TO DRAWINGS AND SPECIFICATIONS OF INTERIOR
PROPRIETARY WATERPROOFING FLUORESCENT WITH OPAL DIFFUSER
PU29 MEMBRANE BONDED TO CONCRETE SLAB. F2 F2 DESIGNER FOR ADDITIONAL INFORMATION.
LED EMERGENCY LIGHT FIXTURE (CEILING / SURFACE
PU40 SURFACE MOUNTED 2x28W T16 E2
THICKNESS AS SHOWN. FLUORESCENT IP65 MOUNTED IP65 - REFER TO THE LIGHTING SCHEDULE
PU08 F3
J10/115 - SURFACE MOUNTED 2x14W T16
LED EXIT SIGNAGE, SINGLE / DOUBLE SIDED
PROPRIETARY 2MM MINIMUM COAT
PU40
FLUORESCENT WITH OPAL DIFFUSER EXIT EX1 EX1
RUNNING MAN PICTOGRAM - IP20
CEMENTITIOUS THIN BED F4
14 WATERPROOFING MEMBRANE TO WET 11 SURFACE MOUNTED 2x28W T15
850
200

FLUORESCENT EXPLOSION PROOF TYPE LED EXIT SIGNAGE, SINGLE / DOUBLE SIDED
EXIT EX2

850
AR-GEN-4-050-05 AREAS. APPLIED VERTICALLY 1200MM AR-GEN-4-050-06 EX2
RUNNING MAN PICTOGRAM - IP65
360

HIGH FROM FFL GENERALLY AND 2000MM F5


MIRROR LIGHT 1x14W T16
HIGH IN SHOWER ROOMS FLUORESCENT IP44
160

300

300
RECESSED MODULAR 4x14W T16 FIRE DETECTION AND ALARM SYSTEM
PU22 H05 H05 L1 FLUORESCENT WITH LOUVRE
H42.02 - FFL +53.85 FFL +53.85 SMOKE DETECTOR 'X' DENOTES
PRECAST CONCRETE PANEL CLADDING X
100 100

100
RECESSED MODULAR 3x14W T16 S
SYSTEM TO FACADE CONSULTANTS L2 FLUORESCENT IP44 I : IONISATION
TOC +53.75 TOC +53.75

100
DETAILS AND SPECIFICATION. O : OPTICAL
RECESSED MODULAR 4x14W T16
L3 FLUORESCENT IP44
F10/350.03 - VOID SMOKE DETECTOR WITH CEILING INDICATOR,
200MM THICK SOLID CONCRETE RECESSED MODULAR 4x14W T16 X
'X' DENOTES
L4 S
BLOCKWORK. FLUORESCENT IP54
D1 RECESSED LED DOWNLIGHT 11W WITH I : IONISATION
IP54 COVER O : OPTICAL
D2 RECESSED LED DOWNLIGHT 18W WITH
IP54 COVER
ENLARGED PLAN - STAFF TOILET. ST-01-DETAIL SECTION ST-03-DETAIL SECTION
HEAT DETECTOR 'X' DENOTES
D3 RECESSED LED DOWNLIGHT 13W IP20
X

9 11 13 D4 RECESSED LED DOWNLIGHT 21W IP20


H F : FIXED TEMPERATURE
R : RATE OF RISE
1 : 20 1 : 20 1 : 20
P1 SPOTLIGHT IP65 VOID HEAT DETECTOR 'X' DENOTES
X
H
DETECTION F : FIXED POINT
R : RATE OF RISE
SURFACE MOUNTED THERMAL DETECTOR
H DENOTES HIGH TEMPERATURE TYPE S DUCT SMOKE DETECTOR
SURFACE MOUNTED SMOKE DETECTOR
ION = IONIZATION, PHO = PHOTOELECTRIC SH COMBINED SMOKE & HEAT DETECTOR

VOID COMBINED SMOKE & HEAT DETECTOR WITH


HE SPRINKLERS
SH
REMOTE INDICATOR

2410 9 SPRINKLER ABBREVIATIONS Tx BEAM SMOKE DETECTOR (TRANSMITTER)

1225 1185 AR-GEN-4-050-09 EC - EXTENDED COVERAGE SPRINKLER HEAD.


1675
HT - HIGH TEMPERATURE SPRINKLER HEAD. Rx BEAM SMOKE DETECTOR (RECEIVER)
1675 100 1950 200 160 400 1175 100 DRY - SPRINKLER HEAD WITH DRY DROPPER.
FD FLAME DETECTOR
HSW - HIRIZONTAL SIDE-WALL SPRINKLER HEAD.
ARCHITECT OF RECORD:
100 1175 400 VSW - VERTICAL SIDE-WALL SPRINKLER HEAD.
F10/350.01 - H HEAT DETECTOR WITH ALARM SOUNDER
100MM THICK SOLID CONCRETE
BLOCKWORK. 360° NOZZLE FOR CLEAN AGENT
SUPPRESSION SYSTERM
S SMOKE DETECTOR WITH ALARM SOUNDER Al Khatib Engineering Bureau
H42.02 - WL01
CEILING
VOID PRECAST CONCRETE PANEL CLADDING
CEILING FULLY RECESSED SPRINKLER
HEAD ON DROPPER
STROBE (CEILING MOUNTED) Consulting Engineers
VOID
SYSTEM TO FACADE CONSULTANTS P PENDANT SPRINKLER HEAD ON DROPPER WITH VA VOICE ALARM SPEAKER C.R.367
DETAILS AND SPECIFICATION. STANDARD OR RAISED ESCUTCHEON PLATE xx
300 E30.02 - 300 235 PENDANT SPRINKLER HEAD ON DROPPER WITH INT INTERFACE MODULE
REINFORCED CAST IN SITU CONCRETE P STANDARD OR RAISED ESCUTCHEON PLATE. TO BE LEAD CONSULTANT / DESIGN ARCHITECT:
FIRE EVACUATION SPEAKER WITH FIRE
SHEAR WALL TO STRUCTURAL FITTED WITH GUARD ES
LINTEL
SOP SOP RATED BACK BOX MIDDLE EAST 2nd Floor 204 Convention
SOP ENGINEERS DETAILS AND SPECIFICATION.
F10/350.03 -
PENDANT CONCEALED SPACE SPRINKLER HEAD Tower Road 312 Zabeel PO Box 9723
Dubai United Arab Emirates
200MM THICK SOLID CONCRETE UPRIGHT EXPOSED SPRINKLER HEAD AIR REGISTERS
1225

Tel +971 4 329 2288 Fax +971 4 329 2289


BLOCKWORK. EXPOSED SPRINKLER HEAD TO BE FITTED WITH GUARD
e-mail: dxbmail@dsa-arch.com
EXPOSED OPEN SPRINKLER HEAD
H05-205A SPRINKLER HEAD UNDER A/C DUCTWORK VARIABLE TWIST DIFFUSER
AFRICA 68 Wierda Road East
HSW or Wierda Valley Sandton 2196 PO Box 787588
SIDEWALL SPRINKLER HEAD

DSA
VSW CEILING SUPPLY AIR DIFFUSER 4 WAY Sandton 2146 Gauteng South Africa
SMOOTH GLAZED ANTI-MICROBIAL
2050

HT BLOW, C/W INTERNALLY INSULATED Tel +27 11 779 1600 Fax +27 11 779 1602
CERAMIC WALL TILE - SIZE 300 X 300 MM SPRINKLER IN KITCHEN EXHAUST DUCT PLENUM BOX
182° e-mail: mail@dsa-arch.com
THICKNESS 6.0MM - COLOUR RAL 9016
2410

MATTE WHITE WITH WHITE POWDER COATED STAFF HT


SPRINKLER HEAD WITH HEAT TRAP/WATER SHIELD 2 AND 3 WAY BLOW CEILING
141°
HE ALUMINIUM EXTERNAL CORNER BEADING TOILET
H05-205 SPRINKLER IN/ UNDER KITCHEN EXHAUST
SUPPLY AIR DIFFUSER. ARCHITECTS
EUROPE
2700
2700

2700
2700
- VITRA ARCHITEKT OR SIMILAR APPROVED HOOD/ IN LIFT SHAFT Alameda António Sérgio 7, 2ºD
CEILING SUPPLY AIR DIFFUSER
WW
RADIAL SWIRL BLOW.
INTERNATIONAL 2795-023 Linda-à-Velha Lisboa Portugal
STAFF VSW WALL / WINDOW WETTING SPRINKLER Tel +351 214 193 277 Fax +351 214 193 276
TOILET SLOT LINEAR DIFFUSER C/W INTERNALLY africa middle east europe e-mail: dsa.europe@dsa-arch.com
H05-205 MULTIPLE JET CONTROL LINED AIR BOOT).
2100

FLOOR MOUNTED CIRCULAR


825

SUPPLY AIR DIFFUSER. PROJECT:


AV & IT ELECTRICAL SYMBOLS
SIDEWALL SUPPLY AIR DIFFUSER
PU19
PU08 PU23
4" CEILING LOUDSPEAKER
C/W OBD. AQUA RAFFLES JEDDAH
SIDEWALL LINEAR FIXED BARS C/W
A
M10/112 - PLENUM BOX.
UNBONDED SAND CEMENT SCREED LAID 5" IP RATED CEILING LOUDSPEAKER CEILING RETURN AIR GRILLE C/W
TO MINIMUM FALLS 1:100 OVER B PLENUM BOX. SITE:
PROPRIETARY WATERPROOFING
PU23
AL CORNICHE ROAD | AL SHATE'E DISTRICT
1000

1000

6" CEILING LOUDSPEAKER


200

MEMBRANE BONDED TO CONCRETE SLAB. SIDEWALL RETURN AIR GRILLE C/W


ANTI-SLIP MATTE FINISH HEAVY DUTY C PLENUM BOX.
JEDDAH | KINGDOM OF SAUDI ARABIA
360

PORCELAIN TILE - SIZE 300 X 300 MM THICKNESS AS SHOWN.


THICKNESS 8.0 MM - PU22 8" CEILING LOUDSPEAKER CEILING EXHAUST AIR GRILLE C/W
160

COLOUR DOTTI COROUND IVORY - VITRA D PLENUM BOX.


300

ARCHITEKT OR SIMILAR APPROVED 12" CEILING LOUDSPEAKER


400

400

H05 H05 E
SIDEWALL EXHAUST AIR GRILLE C/W DRAWING DESCRIPTION:

FFL +53.85 FFL +53.85 PLENUM BOX.


HOTEL TOWER
100 100

100

8" CEILING SUBWOOFER LOUDSPEAKER CEILING TRANSFER AIR GRILLE C/W


S PLENUM BOX.
TOC +53.75
SIDEWALL TRANSFER AIR GRILLE C/W
ENLARGED DETAIL
OS CEILING MOUNTED OCCUPANCY SENSOR
J10/115 -
PROPRIETARY 2MM MINIMUM COAT
PLENUM BOX.
OUTSIDE AIR INTAKE LOUVRE.
BOH ROOMS
CEMENTITIOUS THIN BED WAP (WIRELESS ACCESS POINT) WITH
RJ-45 DATA OUTLET. EXHAUST AIR LOUVRE.
WATERPROOFING MEMBRANE TO WET SCALE: SHEET SIZE: CURRENT REVISION DATE: DRAWN BY: CHECK BY:
AREAS. APPLIED VERTICALLY 1200MM WAP (WIRELESS ACCESS POINT) WITH
HIGH FROM FFL GENERALLY AND 2000MM WP RJ-45 DATA OUTLET. As indicated A0 04/05/2017 HH JK
STAFF TOILET RCP PLAN - BOH ST-02-DETAIL SECTION ST-04-DETAIL SECTION HIGH IN SHOWER ROOMS LV LOW VOLTAGE INTERFACE BOX - TYPE 1 BOX
DWG NO: DWG STAGE

10 12 14 MOUNTED AS SHOWN ON DRAWINGS. UON.


MICRO SWITCH/SENSOR FOR DOOR/WINDOW, 12128 -AR- HOT-4-206-00
CON
1 : 20 1 : 20 1 : 20 MS
MOUNTED ABOVE THE DOOR OR WINDOW JOB NO: CONSULTANT BUILDING NUMBER REV O
C:\Users\abdulh\Desktop\Jolish\12128-AR-HOT-0-900-00_Central.rvt DATE STARTED:
PIR PIR DETECTOR FOR BALCONY LIGHT OFF ONLY 02/24/15