You are on page 1of 7

Project detail Bateen Marina Resort Development

System Parapet Mounted Bracket System


description
Title calculation of total suspended load (TSL) & WLL

Input Data:

Self-weight of Platform in Kg (SWP) 600 Kg


Rated Load in Kg ( safe working load) (RL) 500 Kg
Maximum Height of lift in Meters (HOL) 50 Mtr.
Mass of wire rope per meter in Kg 0.35 Kg
Mass of electric cable per meter in Kg 0.27Kg
Total mass of wire rope (Mwr) 77 Kg
Total mass of electric cable (Mc) 27 Kg
Exposed area of wind at cradle (Awc) 2.2 Mtr.²
Diameter of wire rope used in MM 8.3

Specifications of wire rope :

Diameter in MM Mass in kg/m MBL in KN

Results:
Total suspended loads(TSL) = RL + SWP + Mwr + Mc

= 1204 Kg

= 11.8 KN

Working load limit for single bracket (WLL) =


SWP + Mwr + Mc
RL +
= 2
100
= 9 KN

Project detail
System Parapet Mounted Bracket System
description
Title Load on support anchors

Input Data :

Loads in Kilo Newtons

Working load limit (WLL) = 9 KN

Mass of suspension rig (Bracket) (SWR) = 0.6 KN

Distances in MM

Suspension point distance (Lo) in MM = 1050

Vertical spacing of anchors (Ls) = 400

C.G. of bracket from face (Lb) = 525

𝑅ℎ × 𝐿𝑠 = 𝐶𝑤𝑟 × 𝑊𝐿𝐿 × 𝐿𝑜 + 𝑆𝑊𝑅 × 𝐿𝑏 ………… (1)

𝐹𝑠 = 𝐶𝑤𝑟 × 𝑊𝐿𝐿 + 𝑆𝑊𝑅 …………..(2)


Equations (1) and (2) as per EN-1808

Where Cwr, the working coefficient for suspension rig is equal to or


greater than 3

𝐶𝑤𝑟×𝑊𝐿𝐿×𝐿𝑜 +𝑆𝑊𝑅×𝐿𝑏
Horizontal reaction on bracket (Rh) =
𝐿𝑠

= 71.66 KN

Shearing / vertical force (Fs) = 𝐶𝑊𝑅 × 𝑊𝐿𝐿 + 𝑆𝑊𝑅

= 27.6

The max. tensile load per each bolt = Rh/4 = 18 KN

Characteristic resistance of tensile load for M16 bolts = 35 KN

Shear force on Each anchor = Fs/6 = 4.6 KN

Characteristic resistance of shear load for M16 bolts = 39 KN

You might also like