SESMIC ANALYSIS OF MULTISTORED BUILDING G+10 USING E-TAB SOFTWARE

SEISIMC Analysis of Multi Storied Building G+10

HAKIZIMANA DOMINIQUE (1ST15CV040), BISWAJIT MANDAL( 1ST15CV033) ,


BIPIN KUMAR MANDAL( 1ST15CV030) , NAGESH G N (1ST16CV417), (Student,
Department of Civil Engineering, SAMBHRAM College of Engineering), BANGALORE 560097,
UNDER THE GUIDANCE B R SHILPA

ABSTRACT Ordinary moment resisting frame


and special moment resisting frame.
Earthquake occurred in multistoried Equivalent static analysis and
building shows that if the structures response spectrum analysis are the
are not well designed and methods used in structural seismic
constructed with and adequate analysis. We considered the
strength it leads to the complete residential building of G+ 10 storied
collapse of the structures. To ensure structure for the seismic analysis and
safety against seismic forces of it is located in zone II. The total
multi-storied building hence, there is structure was analyzed by computer
need to study of seismic analysis to with using E tabs software. We
design earthquake resistance observed the response reduction of
structures. In seismic analysis the cases ordinary moment resisting
response reduction was considered frame and special moment resisting
for two cases both Ordinary moment frame values with deflection
resisting frame and Special moment diagrams in static and dynamic
resisting frame. The main objective analysis. The special moment of
this paper is to study the seismic resisting frame structured is good in
analysis of structure for static and resisting the seismic loads.
dynamic analysis in
Keywords – Equivalent static
analysis, response spectrum
SESMIC ANALYSIS OF MULTISTORED BUILDING G+10 USING E-TAB SOFTWARE

analysis, ordinary moment resisting structure. For high performance, the


frame, special moment resisting building is designed as an SMRF. It
frame, E TABS SOFTWARE. needs to be designed only for lesser
forces than it is designed as an
I. INTRODUCTION
OMRF.
At present people are facing
1.1 MOMENT RESISTING
problems of land scarcity, cost of
FRAME:
land. The population explosion and
The frame whose member
advent of industrial revolution led to
and joints resist the forces
the migration of people from villages
primarily caused by flexure
to urban areas i.e. construction of
is Moment resisting frame.
multi-storied buildings has become
inevitable both for residential and as 1.1.1 Ordinary Moment Resisting
well as office purposes. The high Frame:
raised structures are not properly
The moment resisting frame which
designed for the resistance of lateral
are designed without any special
forces. It may cause to the complete
attention towards ductile nature of
failure of the structures. The
the frame are called ordinary
earthquake resistance structures are
moment resisting frames.
designed based on some factors. The
factors are 1.1.2 Special Moment Resisting
Frame:
 natural frequency of the
structure, The moment resisting frame which
 damping factor, are designed to have ductile nature
 type of foundation, are called as special moment
 Importance of the building resisting frames. The design is done
and ductility of the structure. according to the requirements
specified in IS-13920. The
The structures designed for ductility earthquake resistant designs of
need to be designed for less lateral structures are considering the
loads as it has better moment following magnitudes of an
distribution qualities. This aspect is earthquake.
taken care of by response reduction
factor R for different type of 1.2 Design Basis Earthquake
(DBE): The earthquake whose
SESMIC ANALYSIS OF MULTISTORED BUILDING G+10 USING E-TAB SOFTWARE

probability of occurrence is at least It is one of the method for


one during the structure design life is calculating the seismic loads. The
called design basis earthquake. high rise structures are not
considered for the design simple
1.3 Maximum Considered
static method. In practical as it does
Earthquake (MCE): The
not take into account all the factors
earthquake whose expected intensity
that are the importance of the
is maximum that can occur in a
foundation condition. The
particular area or region is called
equivalent static analysis is used to
maximum considered earthquake.
design only for the small structures.
The maximum values are considered
In this method only one mode is
as per code. The design approach
considered for each direction. The
recommended by IS: 1893-2002 is
earthquake resistant designing for
based on the following principles
the low rise structures the equivalent
(clause 6.1).
static method is enough. Tall
i. The structure should have the structures are needed more than two
strength to withstand minor modes and mass weight of each story
earthquakes less than DBE without to design earthquake resistant loads.
any damage. This is not suitable to design those
structures and dynamic analysis
i.i The structure should be able to method to be used for high rise
resist earthquakes equal to DBE structures.
without significant structural
damage though some non-structural 2. 2 Response Spectrum Analysis:
damage may occur.
The seismic forces strikes the
foundation of a structure will move
with the ground motion. It shows
iii. The structure should withstand an that structure movement is generally
earthquake equal to MCE without more than the ground motion. The
collapse. movement of the structure as
II. METHODS OF ANALYSIS compared to the ground is refused as
the dynamic amplification. It
2.1 Equivalent Static Analysis: depends on the natural frequency of
vibration, damping, type of
foundation, method of detailing of
SESMIC ANALYSIS OF MULTISTORED BUILDING G+10 USING E-TAB SOFTWARE

the structure. The response “design iv 0.05 0.24


acceleration spectrum” which refers lll 0.04 0.16
to the max acceleration called ll 0.02 0.1
spectral acceleration coefficient
Sa/g, as a function of the structure
for a specified damping ratio for
earthquake excitation at the base for
a single degree freedom system. The
revised IS 1893-2002 uses the
dynamic analysis by response
spectrum. In this method takes into
account all the five important
engineering properties of the
structures.
i. The fundamental natural period of
vibration of the building ( T in
seconds)
ii. The damping properties of the
structure IV. MODAL GENERATION
iii. Type of foundation provided for AND ANALYSIS:
the building We considered a residential
iv. Importance factor of the building building of plan with y-axis
v. The ductility of the structure consisted of G+10 floors. The
represented by response reduction ground floor 4m and rest of the 10
factor. floor had a height of 3m each. the
supports at the base of the structure
III. ZONE FACTORS FOR were also specified as fixed. The
DIFFERENT ZONES IN INDIA structure was subjected to
zones Seismic Seismic  self-weight
coefficient zone  dead load
of 1984 factor (z  live load
of 2002)
v 0.08 0.36
SESMIC ANALYSIS OF MULTISTORED BUILDING G+10 USING E-TAB SOFTWARE

Values considering by the


specifications of IS 875 part-1 and
part-2. The wind load values were
generated by E TABS considering the given wind intensities at different
heights and strictly abiding by the specifications of IS 875 part-3. The
Seismic load calculations of Static and Dynamic analysis were done following
IS 1893-2002

Fig.1 column positions and plan of G +10 building


SESMIC ANALYSIS OF MULTISTORED BUILDING G+10 USING E-TAB SOFTWARE
SESMIC ANALYSIS OF MULTISTORED BUILDING G+10 USING E-TAB SOFTWARE

Plan View (Unit in m)

6.00 m 6.00 m 6.00 m


6.00 m

2.00 2.00 2.00

2.00 2.00 2.00


6.00 m
6.00 m

BASE – STORY 7

6.00 m 6.00 m 6.00 m


6.00 m

2.00 2.00 2.00


2.00 2.00 2.00
6.00 m
6.00 m

STORY 8 – STORY 10
SESMIC ANALYSIS OF MULTISTORED BUILDING G+10 USING E-TAB SOFTWARE

Elevation view

Material Properties for Concrete (Unit in kg and cm)

Section Properties

Member Dimension

Beam (width x Height) 30 x 60 cm

Column 50 x 50 cm

Slab Thickness = 15 cm

Shear wall Thickness = 20 cm


SESMIC ANALYSIS OF MULTISTORED BUILDING G+10 USING E-TAB SOFTWARE

Story Height Data

Story Height
Typical Story 3.00 m
Story at base of 4.00 m
building

Static Load Cases

Load
Name Load Details Value
Type
Self Weight of
Structural -
Members Calculate
automatically
DEAD Dead using Self Weight
Load Multiplier in
ETABS
Uniform
Load on 0.20 t/m2
Slabs:
(Finishing +
Partition
Load)
Uniform
Lo 0.50 t/m
ad
on
Be
am
s:
(W
all
SESMIC ANALYSIS OF MULTISTORED BUILDING G+10 USING E-TAB SOFTWARE

Lo
ad)
Red Uniform 0.25 t/m2
LIVE ucib Load on
le Slabs: (Use
Live Tributary
Loa Area:
d UBC97)

ELCENTRO Time History Function

1 1 1 1 1

Time
SESMIC ANALYSIS OF MULTISTORED BUILDING G+10 USING E-TAB SOFTWARE
SESMIC ANALYSIS OF MULTISTORED BUILDING G+10 USING E-TAB SOFTWARE

V. CONCLUSION values are high compare to static analysis.


The results in graph-6 shows that the
The obtained results of static and
values are obtained for torsion in static
dynamic analysis in OMRF & SMRF are
analysis are negative and dynamic
compared for different columns under
analysis values are positive with more
axial, torsion, bending moment and
difference. In the results graph, we can
displacement forces. The results in graph-
observe that the values for bending
1 shows that there is equal values
moment at dynamic analysis values are
obtained of axial forces in static and
more as compared to that of static
dynamic analysis of OMRF structure.
analysis SMRF structure. In the results
The results in graph shows that the values
graph, we can observe that the values for
are obtained for torsion in static analysis
displacement in dynamic analysis of
are negative and dynamic analysis values
SMRF values are gradually increased
are positive. The results in graph here we
compared to that of static analysis values
can observe that the values for bending
of same columns. The static and dynamic
moment at dynamic analysis values are
analysis of OMRF & SMRF values are
high in initially for other columns it
observed. Finally it can conclude that the
decreased gradually as compared to that
results of static analysis in OMRF &
of static analysis. The results in graph we
SMRF values are low when comparing to
can observe that the values for
that of dynamic analysis in OMRF &
displacement in static analysis of OMRF
SMRF values. Hence the performance of
values are more compared to that of
dynamic analysis SMRF structure is quiet
dynamic analysis values of same
good in resisting the earthquake forces
columns. The results in graph shows that
compared to that of the static analysis
the values obtained of axial forces in
OMRF & SMRF
dynamic analysis of SMRF structure
.
SESMIC ANALYSIS OF MULTISTORED BUILDING G+10 USING E-TAB SOFTWARE
SESMIC ANALYSIS OF MULTISTORED BUILDING G+10 USING E-TAB SOFTWARE