You are on page 1of 114

Tabla 1.10. Caudales máximos probables. Método de Hunter.

Tuberías d

Rugosidad k (mm) 0.007 C= 140

Temperatura
del agua ºC 10

Viscosidad del
agua ν (m2/s) 1.308E-06
Diámetro nominal DN (mm)
15
Caudales Sf Sf (Hazen
(L/s) Número de Factor de (Univ.) Willians) Sf
Velocidad Error
Reynolds fricción "λ" (mm/m) (mm/m) Flamant
(m/s) absoluto
"R" (mm/m)

0.10 0.57 6489 0.0353 5.6E-07 38 34 65


0.15 0.85 9734 0.0318 6.2E-07 78 72 132
0.18 1.02 11681 0.0304 2.1E-07 107 100 181
0.20 1.13 12979 0.0297 3.0E-07 129 122 218
0.23 1.30 14926 0.0287 8.5E-07 165 158 278
0.25 1.41 16224 0.0282 8.6E-07 191 184 322
0.28 1.58 18171 0.0275 3.6E-07 234 227 392
0.30 1.70 19468 0.0270 1.3E-07 265 258 442
0.33 1.87 21415 0.0265 6.4E-07 314 308 523
0.35 1.98 22713 0.0262 8.8E-08 349 344 580
0.38 2.15 24660 0.0257 1.6E-07 404 400 669
0.40 2.26 25958 0.0254 5.7E-07 443 440 732
0.43 2.43 27905 0.0251 1.3E-07 504 503 831
0.45 2.55 29203 0.0248 6.2E-07 547 547 900
0.48 2.72 31150 0.0245 1.1E-07 615 617 1007
0.50 2.83 32447 0.0243 4.5E-07 662 665 1082
0.53 3.00 34394 0.0240 3.0E-07 735 741 1198
0.55 3.11 35692 0.0239 2.3E-07 786 794 1278
0.58 3.28 37639 0.0236 7.4E-07 865 876 1403
0.60 3.40 38937 0.0235 5.7E-07 920 933 1488
0.63 3.57 40884 0.0233 3.8E-07 1005 1021 1621
0.65 3.68 42182 0.0231 2.9E-07 1064 1081 1712
0.68 3.85 44129 0.0230 1.9E-07 1155 1176 1853
0.70 3.96 45426 0.0228 9.2E-07 1218 1241 1949
0.73 4.13 47373 0.0227 6.3E-07 1315 1341 2098
0.75 4.24 48671 0.0226 4.9E-07 1381 1410 2199
0.78 4.41 50618 0.0224 3.3E-07 1484 1516 2356
0.80 4.53 51916 0.0223 2.5E-07 1554 1589 2462
0.83 4.70 53863 0.0222 1.6E-07 1662 1701 2626
0.85 4.81 55161 0.0221 1.2E-07 1736 1777 2738
0.88 4.98 57108 0.0220 7.4E-07 1851 1895 2909
0.90 5.09 58405 0.0219 5.7E-07 1928 1976 3026
0.93 5.26 60352 0.0218 3.8E-07 2048 2099 3205
0.95 5.38 61650 0.0217 2.8E-07 2130 2184 3326
0.98 5.55 63597 0.0216 1.8E-07 2255 2313 3512
1.00 5.66 64895 0.0215 1.4E-07 2341 2401 3639
1.10
1.20
1.30
1.40
1.50
1.60
1.70
1.80
1.90
2.00
2.10
2.20
2.30
2.40
2.50
2.60
2.70
2.80
2.90
3.00
3.10
3.20
3.30
3.40
3.50
3.60
3.70
3.80
3.90
4.00
4.10
4.20
4.30
4.40
4.50
4.60
4.70
4.80
4.90
5.00
probables. Método de Hunter. Tuberías de PVC

Diámetro nominal DN (mm) Diámetro


20
Sf (Univ.) Sf (Hazen
Número de (mm/m) Willians) Sf Número de
Velocidad Factor de Error Velocidad
Reynolds (mm/m) Flamant Reynolds
(m/s) fricción "λ" absoluto (m/s)
"R" (mm/m) "R"

0.32 4867 0.0381 4.3E-07 13 8 17


0.48 7301 0.0341 9.8E-07 26 18 34 0.31 5841
0.57 8761 0.0325 2.9E-07 27 25 46 0.37 7009
0.64 9734 0.0316 5.1E-07 33 30 55 0.41 7787
0.73 11194 0.0305 3.3E-07 42 39 71 0.47 8956
0.80 12168 0.0299 9.8E-07 48 45 82 0.51 9734
0.89 13628 0.0291 2.3E-07 59 56 100 0.57 10902
0.95 14601 0.0286 7.4E-07 67 64 113 0.61 11681
1.05 16062 0.0280 1.4E-07 79 76 133 0.67 12849
1.11 17035 0.0276 4.9E-07 87 85 148 0.71 13628
1.21 18495 0.0271 9.4E-07 101 99 171 0.77 14796
1.27 19468 0.0268 4.1E-07 111 108 187 0.81 15575
1.37 20929 0.0264 2.4E-08 126 124 212 0.88 16743
1.43 21902 0.0261 2.6E-08 136 135 229 0.92 17522
1.53 23362 0.0257 1.7E-07 153 152 257 0.98 18690
1.59 24336 0.0255 7.3E-07 165 164 276 1.02 19468
1.69 25796 0.0252 2.3E-07 183 183 305 1.08 20637
1.75 26769 0.0250 9.6E-08 195 196 326 1.12 21415
1.85 28229 0.0247 3.4E-07 215 216 358 1.18 22583
1.91 29203 0.0245 1.3E-07 228 230 380 1.22 23362
2.01 30663 0.0243 5.3E-07 249 251 413 1.28 24530
2.07 31636 0.0241 1.5E-07 263 266 437 1.32 25309
2.16 33096 0.0239 5.2E-07 286 290 472 1.39 26477
2.23 34070 0.0238 3.7E-08 301 306 497 1.43 27256
2.32 35530 0.0236 3.1E-07 324 330 535 1.49 28424
2.39 36503 0.0235 2.1E-07 341 347 561 1.53 29203
2.48 37964 0.0233 1.1E-07 366 373 601 1.59 30371
2.55 38937 0.0232 7.3E-07 383 391 628 1.63 31150
2.64 40397 0.0230 3.852E-07 409 419 670 1.69 32318
2.71 41371 0.0229 2.4393E-07 427 438 698 1.73 33096
2.80 42831 0.0227 1.1627E-07 455 467 742 1.79 34265
2.86 43804 0.0226 6.7885E-08 474 487 772 1.83 35043
2.96 45264 0.0225 5.344E-07 503 517 817 1.89 36211
3.02 46238 0.0224 3.0848E-07 522 538 848 1.94 36990
3.12 47698 0.0223 1.2083E-07 553 570 896 2.00 38158
3.18 48671 0.0222 5.8565E-08 573 592 928 2.04 38937
3.50 53538 0.0218 8.8897E-07 682 706 1096 2.24 42831
3.82 58405 0.0215 9.4632E-07 799 829 1277 2.44 46724
4.14 63273 0.0212 0.0000007 924 962 1469 2.65 50618
4.46 68140 0.0209 3.8887E-07 1059 1103 1672 2.85 54512
4.77 73007 0.0207 6.3677E-07 1202 1253 1886 3.06 58405
5.09 77874 0.0205 8.3114E-07 1353 1412 2112 3.26 62299
5.41 82741 0.0203 6.1845E-07 1513 1580 2348 3.46 66193
5.73 87608 0.0201 9.5058E-07 1681 1757 2595 3.67 70087
6.05 92475 0.0199 3.5594E-07 1857 1942 2853 3.87 73980
6.37 97342 0.0198 3.7621E-07 2042 2135 3121 4.07 77874
4.28 81768
4.48 85661
4.69 89555
4.89 93449
5.09 97342
5.30 101236
5.50 105130
5.70 109024
5.91 112917
6.11 116811
6.32 120705
6.52 124598
6.72 128492
6.93 132386
7.13 136279
7.33 140173
7.54 144067
7.74 147961
0

Diámetro nominal DN (mm) Diámetro nominal DN (


25 40
Sf (Univ.) Sf (Hazen
(mm/m) Willians) Sf Número de
Factor de Velocidad Factor de
Error absoluto (mm/m) Flamant Reynolds
fricción "λ" (m/s) fricción "λ"
(mm/m) "R"

0.0361 5.0E-07 7
0.0344 3.6E-07 9 8 16
0.0334 3.8E-07 11 10 19
0.0322 8.7E-07 14 13 25
0.0315 4.4E-07 17 15 28
0.0306 4.2E-07 20 19 35
0.0301 2.2E-07 23 21 39
0.0294 3.0E-07 27 26 46
0.0290 2.0E-07 30 29 51
0.0284 4.0E-07 35 33 59 0.30 9,248 0.0319
0.0281 2.0E-07 38 37 65 0.32 9,734 0.0315
0.0276 4.8E-07 43 42 73 0.34 10,464 0.0310
0.0273 2.3E-07 47 45 79 0.36 10,951 0.0306
0.0269 3.8E-07 52 51 89 0.38 11,681 0.0301
0.0267 2.3E-07 56 55 96 0.40 12,168 0.0298
0.0263 5.7E-07 63 62 106 0.42 12,898 0.0294
0.0261 1.7E-08 67 66 113 0.44 13,385 0.0291
0.0258 1.9E-07 73 73 124 0.46 14,115 0.0287
0.0256 9.0E-07 78 77 132 0.48 14,601 0.0285
0.0253 3.5E-07 85 85 143 0.50 15,331 0.0282
0.0251 1.7E-07 90 90 151 0.52 15,818 0.0280
0.0249 7.6E-07 97 98 164 0.54 16,548 0.0277
0.0247 3.6E-07 103 103 172 0.56 17,035 0.0275
0.0245 1.0E-07 110 111 185 0.58 17,765 0.0272
0.0244 8.5E-07 116 117 194 0.60 18,252 0.0268
0.0242 1.8E-07 124 126 208 0.62 18,982 0.0266
0.0240 4.7E-08 130 132 218 0.64 19,468 0.0264
0.0238 1.7E-07 139 141 232 0.66 20,199 0.0262
0.0237 7.4E-09 145 148 242 0.68 20,685 0.0261
0.0236 2.9E-07 154 157 257 0.70 21,415 0.0258
0.0235 2.0E-07 161 164 267 0.72 21,902 0.0257
0.0233 1.1E-07 170 174 283 0.74 22,632 0.0255
0.0232 8.2E-07 177 181 294 0.76 23,119 0.0254
0.0230 4.8E-07 187 192 310 0.78 23,849 0.0252
0.0230 3.2E-07 194 200 321 0.80 24,336 0.0251
0.0225 6.1E-07 231 238 380 0.88 26,769 0.0246
0.0221 3.4E-08 270 280 442 0.95 29,203 0.0241
0.0218 7.4E-07 312 324 509 1.03 31,636 0.0237
0.0215 8.6E-08 357 372 579 1.11 34,070 0.0233
0.0212 7.6E-07 404 423 654 1.19 36,503 0.0230
0.0210 4.5E-07 455 476 732 1.27 38,937 0.0226
0.0208 8.1E-07 508 533 814 1.35 41,371 0.0224
0.0206 3.8E-07 563 593 899 1.43 43,804 0.0221
0.0204 3.5E-07 622 655 989 1.51 46,238 0.0219
0.0202 5.1E-07 683 720 1081 1.59 48,671 0.0216
0.0200 3.0E-07 747 788 1178 1.67 51,105 0.0214
0.0199 3.6E-07 814 859 1278 1.75 53,538 0.0212
0.0197 3.6E-07 883 933 1381 1.83 55,972 0.0210
0.0196 3.4E-07 955 1009 1488 1.91 58,405 0.0209
0.0195 1.0E-06 1029 1089 1598 1.99 60,839 0.0207
0.0193 8.5E-07 1106 1171 1711 2.07 63,273 0.0205
0.0192 7.2E-07 1186 1255 1828 2.15 65,706 0.0204
0.0191 6.1E-07 1268 1343 1948 2.23 68,140 0.0202
0.0190 5.2E-07 1353 1433 2072 2.31 70,573 0.0201
0.0189 4.4E-07 1441 1526 2199 2.39 73,007 0.0200
0.0188 3.7E-07 1531 1622 2328 2.47 75,440 0.0199
0.0187 3.1E-07 1624 1720 2461 2.55 77,874 0.0197
0.0187 2.7E-07 1719 1821 2598 2.63 80,308 0.0196
0.0186 9.4E-07 1817 1924 2737 2.71 82,741 0.0195
0.0185 8.2E-07 1918 2030 2879 2.79 85,175 0.0194
0.0184 7.1E-07 2021 2139 3025 2.86 87,608 0.0193
0.0184 6.1E-07 2127 2250 3173 2.94 90,042 0.0192
0.0183 5.3E-07 2235 2364 3325 3.02 92,475 0.0191
3.10 94,909 0.0191
3.18 97,342 0.0190
3.26 99,776 0.0189
3.34 102,210 0.0188
3.42 104,643 0.0187
3.50 107,077 0.0187
3.58 109,510 0.0186
3.66 111,944 0.0185
3.74 114,377 0.0185
3.82 116,811 0.0184
3.90 119,245 0.0183
3.98 121,678 0.0183
Diámetro nominal DN (mm) Diámetro nominal DN (mm)
40 50
Sf (Universal) Sf (Hazen
(mm/m) Willians) Sf Número de
Velocidad Factor de
Error absoluto (mm/m) Flamant Reynolds Error absoluto
(m/s) fricción "λ"
(mm/m) "R"

4.9E-07 4 3 6
4.6E-07 4 4 7
4.2E-07 5 4 8
4.0E-07 5 5 9
3.7E-07 6 5 10
3.5E-07 6 6 10
3.2E-07 7 6 11
3.1E-07 7 7 12
2.9E-07 8 7 13 0.30 11,292 0.0301 6.3E-07
2.7E-07 8 8 14 0.31 11,681 0.0299 2.1E-07
2.6E-07 9 9 15 0.32 12,265 0.0295 3.1E-07
2.5E-07 10 9 16 0.33 12,655 0.0293 2.7E-07
2.3E-07 10 10 18 0.35 13,239 0.0290 1.8E-07
2.2E-07 11 10 18 0.36 13,628 0.0287 9.1E-07
2.1E-07 12 11 20 0.37 14,212 0.0284 4.3E-07
4.2E-07 12 12 21 0.38 14,601 0.0283 1.9E-07
1.2E-07 13 13 22 0.40 15,185 0.0280 2.0E-07
2.9E-08 14 13 23 0.41 15,575 0.0278 4.7E-07
1.7E-07 15 14 25 0.42 16,159 0.0276 4.5E-07
5.2E-09 15 15 26 0.43 16,548 0.0274 3.2E-07
2.4E-07 16 16 28 0.45 17,132 0.0272 1.0E-07
1.5E-07 17 17 29 0.46 17,522 0.0270 7.5E-07
7.3E-07 18 18 30 0.47 18,106 0.0268 4.2E-07
4.8E-07 18 18 32 0.48 18,495 0.0267 2.7E-07
2.4E-07 20 19 33 0.50 19,079 0.0265 6.6E-07
1.5E-07 20 20 34 0.51 19,468 0.0264 2.2E-08
1.4E-07 24 24 41 0.56 21,415 0.0258 1.9E-07
9.1E-08 28 28 47 0.61 23,362 0.0253 2.8E-07
9.3E-08 32 33 55 0.66 25,309 0.0248 4.9E-07
1.1E-07 37 38 62 0.71 27,256 0.0244 9.1E-07
3.2E-07 42 43 70 0.76 29,203 0.0240 3.1E-08
6.7E-08 47 48 78 0.81 31,150 0.0237 2.7E-08
2.1E-07 52 54 87 0.87 33,096 0.0233 1.4E-07
7.2E-07 58 60 96 0.92 35,043 0.0231 4.8E-07
1.9E-08 64 66 106 0.97 36,990 0.0228 1.5E-07
5.0E-07 70 73 116 1.02 38,937 0.0225 6.4E-07
7.4E-07 76 80 126 1.07 40,884 0.0223 1.4E-07
7.1E-07 83 87 137 1.12 42,831 0.0221 6.6E-07
4.8E-07 90 95 148 1.17 44,778 0.0219 3.8E-08
3.1E-07 97 102 160 1.22 46,724 0.0217 4.7E-07
6.3E-07 104 110 171 1.27 48,671 0.0215 8.4E-08
3.4E-07 112 119 184 1.32 50,618 0.0213 8.7E-07
4.5E-07 120 127 196 1.38 52,565 0.0212 6.4E-07
5.5E-07 128 136 209 1.43 54,512 0.0210 4.6E-07
8.0E-07 136 145 222 1.48 56,459 0.0209 3.2E-07
3.1E-07 145 155 236 1.53 58,405 0.0207 7.0E-07
3.5E-07 154 164 250 1.58 60,352 0.0206 4.3E-07
3.5E-07 163 174 264 1.63 62,299 0.0205 7.9E-07
3.4E-07 173 185 279 1.68 64,246 0.0203 9.0E-07
3.1E-07 182 195 294 1.73 66,193 0.0202 3.0E-07
9.2E-07 192 206 309 1.78 68,140 0.0201 8.2E-07
8.0E-07 202 217 324 1.83 70,087 0.0200 3.0E-07
7.0E-07 212 228 340 1.88 72,033 0.0199 3.4E-07
6.1E-07 223 240 357 1.94 73,980 0.0198 3.5E-07
5.3E-07 234 251 373 1.99 75,927 0.0197 3.4E-07
4.6E-07 245 263 390 2.04 77,874 0.0196 3.3E-07
4.0E-07 256 276 407 2.09 79,821 0.0195 3.0E-07
3.4E-07 268 288 425 2.14 81,768 0.0194 9.0E-07
3.0E-07 280 301 443 2.19 83,715 0.0193 8.0E-07
2.6E-07 292 314 461 2.24 85,661 0.0192 7.1E-07
9.3E-07 304 328 479 2.29 87,608 0.0192 6.2E-07
8.2E-07 316 341 498 2.34 89,555 0.0191 5.5E-07
7.2E-07 329 355 517 2.39 91,502 0.0190 4.9E-07
6.3E-07 342 369 537 2.44 93,449 0.0189 4.3E-07
5.5E-07 355 384 556 2.50 95,396 0.0189 3.8E-07
9.0E-07 369 398 576 2.55 97,342 0.0188 3.3E-07
0.000001
o nominal DN (mm) Diámetro nominal DN (mm)
50 75
Sf (Universal) Sf (Hazen Sf (Universal)
(mm/m) Willians) Número de (mm/m)
Fórmula Velocidad Factor de
(mm/m) Reynolds Error absoluto
Flamant (m/s) fricción "λ"
"R"

3 2 5
3 3 5
3 3 5
3 3 6
4 3 6
4 4 6
4 4 7
4 4 7
5 4 8
5 5 8
5 5 9
5 5 9
6 5 10
6 6 10
6 6 11
6 6 11
7 7 12
7 7 12
8 8 14
10 10 16
11 11 19
13 13 22 0.32 18,171 0.0268 3.3E-07 3
14 14 24 0.34 19,468 0.0264 3.1E-07 3
16 16 27 0.36 20,766 0.0260 3.0E-07 3
18 18 30 0.38 22,064 0.0256 2.9E-07 4
20 20 33 0.41 23,362 0.0253 2.8E-07 4
22 22 37 0.43 24,660 0.0249 2.7E-07 5
24 25 40 0.45 25,958 0.0247 2.6E-07 5
26 27 44 0.48 27,256 0.0244 2.5E-07 6
28 29 47 0.50 28,554 0.0241 2.5E-07 6
31 32 51 0.52 29,852 0.0239 2.4E-07 7
33 35 55 0.54 31,150 0.0237 2.3E-07 7
36 37 59 0.57 32,447 0.0234 2.2E-07 8
38 40 64 0.59 33,745 0.0232 2.2E-07 8
41 43 68 0.61 35,043 0.0231 2.1E-07 9
44 46 72 0.63 36,341 0.0229 2.1E-07 9
46 49 77 0.66 37,639 0.0227 2.0E-07 10
49 52 82 0.68 38,937 0.0225 2.0E-07 11
52 55 87 0.70 40,235 0.0224 1.9E-07 11
55 59 91 0.72 41,533 0.0222 1.9E-07 12
59 62 97 0.75 42,831 0.0221 1.8E-07 13
62 66 102 0.77 44,129 0.0219 1.8E-07 13
65 69 107 0.79 45,426 0.0218 1.7E-07 14
69 73 112 0.81 46,724 0.0217 1.7E-07 15
72 77 118 0.84 48,022 0.0216 1.6E-07 15
76 81 124 0.86 49,320 0.0214 1.6E-07 16
79 85 129 0.88 50,618 0.0213 1.6E-07 17
83 89 135 0.91 51,916 0.0212 1.5E-07 18
87 93 141 0.93 53,214 0.0211 1.5E-07 19
91 97 147 0.95 54,512 0.0210 1.4E-07 19
95 102 153 0.97 55,810 0.0209 1.4E-07 20
99 106 160 1.00 57,108 0.0208 1.4E-07 21
103 111 166 1.02 58,405 0.0207 1.3E-07 22
107 115 173 1.04 59,703 0.0206 1.3E-07 23
111 120 179 1.06 61,001 0.0205 1.3E-07 24
115 125 186 1.09 62,299 0.0205 1.3E-07 25
120 129 193 1.11 63,597 0.0204 1.2E-07 26
124 134 200 1.13 64,895 0.0203 1.2E-07 27
m)

Sf (Hazen
Willians) Fórmula
(mm/m) Flamant

13 5
14 6
16 7
18 7
20 8
22 9
25 10
27 11
29 11
32 12
35 13
37 14
40 15
43 16
46 18
49 19
52 20
55 21
59 22
62 23
66 25
69 26
73 27
77 29
81 30
85 31
89 33
93 34
97 36
102 37
106 39
111 40
115 42
120 43
125 45
129 47
134 48
Altura Cota Elev.
entrepiso Pisos
Ingreso T.E. 2596.10

8.80

2,587.30

2.60
2,584.70

2.60
2,582.10

2.60
Ciudad La Paz 2,579.50

2.60
Zona Prado 2,576.90

2.60
No de plantas 15.00 2,574.30

2.60
No Departamentos / planta 2.00 2,571.70
No dormitorios p/ Depto. 2.60
(1 Padres y 2 Hijos) 3.00 2,569.10

2.60
Dormitorio de empleada 1.00 2,566.50

2.60
Total Deptos. 28.00 2,563.90

2.60
Altura de entrepiso (m) 2.60 2,561.30

2.60
Cota de referencia P.B (msnm) 2550.00 2,558.70

2.60
Elevación último piso (msnm) 2587.30 2,556.10

2.60
Altura hasta el último piso (m) 37.30 2,553.50

3.50
Área del lote (m2) 450.00 2,550.00

5.00
Area de parkeos, sótano [m2] 300.00 2545.00

Superficie de jardines (m2) 150.00

Superficie por departamento (m2) 120.00

Área comercial [m2] 300.00


Total No. de hidrantes 15.00

Elevación de red pública 2,549.00


(msnm)

Profundidad matriz de AoPo 1.00

Cálculo del Consumo Diario

Tasa de Consumo
Detalle Cantidad ocupación diario
Dotación RENISDA (p/habitació (L/d)
n)
Unidad Dotación

Dormitorio padres L/p.d 120 1.00 2.00 240.00

Dormitorio hijos L/p.d 120 2.00 1.16 279.45

Dormitorio Empleada L / p.d 120 1.00 1.00 120.00

Departamento completo L/p.d 4.16 639.45

Total consumo doméstico Edificio L/d 639 28.00 4.16 17,904.66

Área comercial Edificio PB. L/m2.d 5 300.00 1,500.00

Dormitorio Portero Edificio L / p.d 120 1.00 2.00 240.00

Parqueo sin lavado de automóviles L / m2.d 2.00 300.00 600.00

Riego de jardines L/m2.d 2.00 150.00 300.00

Total consumo comercial y del


edificio. 2,640.00

Total consumo doméstico y


comercial 20,544.66
20.54
Vol. de Almc. consumo diario (m3);

Volumen contra incendio [litros] L/min 250.00 2.00 15.00


Volumen necesario de 35.54
almacenamiento m3

TIPO DE DISTRIBUCIÓN SISTEMA INDIRECTO CON ALMACENAMIENTO: TANQUE ELEVADO + TANQUE BAJO

DIMENSIONES TANQUE ELEVADO Y TANQUE BAJO

Descripción Unid Cantid.

Capacidad de tanque bajo


(3/5 Vol. total) m3 21.326795
Capacidad de tanque elevado
(2/5 CD),m3 m3 14.217863

Volumen total almacenamiento m3 35.544658

Altura tanque elevado m 2.50

Altura cámara de aire m 0.30

Altura útil m 2.20


Dimensión (a) planta tanque
elevado m 2.55

Dimensión (b) planta tanque elevado m 2.55


Volumen neto tanque elevado sin
cámara de aire m3 14.31
m
Altura tanque bajo 2.5
m
Altura cámara de aire 0.3

Altura útil m 2.2

Dimensión (a) planta tanque bajo m 3.15

Dimensión (a) planta tanque bajo m 3.15

Volumen neto tanque bajo m3 21.8295

SISTEMA DE BOMBEO
Características del servicio (hr) 24

Características RENISDA
2011

Máx. No hors. de bombeo,


RENISDA [h] 6.00

No horas de bombeo
adoptado [h] 3.00

Consumo diario (L) 20,544.66

Caudal de bombeo (L/s) 1.90

Caudal de bombeo [L/min] 114.14


Diámetro económicoTub.
impulsión RENISDA (mm),
pág. 156 33.71
Diámetro comercial adoptado
DN (mm), RENISDA 40.00
Altura manométrica de
succión, Hs (m) 3.57 Q (m3/s)

Altura geométrica de succión


(m), tanque bajo 2.35 C

Pérdidas locales, Long. Equiv.


(m): D (m)

Válvula de pié DN 40 11.80

2 Codo 90° 2.60 V (m/s) =

Long. Equivalente, pérdidas


locales por succión (m) 14.40

Long. real de succión (m) 3.85

Long. total de succión (m),


real más equiv. 18.25

Pérdida de carga unitaria


(mm/m) 66.87

Velocidad de flujo (m/s) 1.51

Pérdida de carga total en la


succión (m), fricción y locales 1.22
Altura manométrica de
Impulsión,
Hi (m): 57.37

Altura geométrica de impulsión


(m) 51.10

Pérdidas locales, Long. Equiv.


(m):

1 Llave de paso, compuerta


DN 40 0.30

Válvula de retención DN 40 4.80

15 Codos DN 40 19.50

Long. Equivalente, pérdidas


locales por impulsión (m) 24.60
Long. real de impulsión [m]:
altura geométrica + desarrollo
horizontal [m] 69.10

Longitud total impulsión, real


más equivalente 93.70

Pérdida de carga Unit. Tub.


impulsión(mm/m) 66.87

Velocidad de flujo (m/s) 1.51

Pérdida de carga total en la


impulsión (m). 6.27
Altura manométrica de
bombeo 60.94
Hb (m)

Eficiencia, conjunto motro -


bomba 0.50

Potencia teórica de la Bomba


kw 2.27

Coeficiente de mayoración 1.20

Potencia de diseño kW 2.73

Potencia comercial
adoptada kW 3.00

Consumo de energía kWh / d 8.19

Consumo mensual de energía


kWh/mes 249.04

Costo Energía Bs / kWh 1.20

Costo mensual de energía


(Bs/mes) 298.84

Costo Anual Energía


( Bs ) 3586.13

Diseño tubería de alimentación tanque cisterna

Continuidad del servicio (h) 4 CONDICIONES DE ABASTECIMIENTO DE AGUA EN CBBA.


Consumo diario (L) 20,544.66

Presión dinámica mínima en la


red pública mca 20.00

Tiempo de llenado del tanque


adoptado [h] 4.00
Caudal de alimentación
(L/s),
1.43

Diámetro del ramal de


alimentacción DN 25

Pérdida de carga unitaria por


fricción (mm/m) 386.58

Velocidad (m/s) 2.91

Longitud de tubería, ramal de


alimentación (m) 25.00

Pérdidas localizadas, long.


equivalente 6.25

Long. total equivalente (real


más pérdidas localizadas) 31.25

Pérdidas por fricción y


localizadas (m) 12.08

Pérdidas por medidor DN 25 6.50

Total pérdidas ( fricción,


localizadas más medidor) 18.58

Elevación piezométrica red


pública 2569.00
Elevación de la Tub. de
ingreso al tanque bajo
(msnm) 2547.30
Elevación piezométrica Tub.
ingreso al tanque cisterna
(msnm) 2550.42

Presión dinámica disponible O.K > 1,5 mca


(m) 3.12
No de
Pisos

Determinación, Tasa de ocupación


Cantidad
15 Ambiente Unidad Dorm. Días/año Tasa
2
14 Dorm. Padres persona 365 2.00
2
13 Dorm. Hijos persona 365 1.16
1
12 Dor.Empleada persona 365 1.00

11

10

1 Área comercial
2549.00
Sótano

Red pública de agua potable


o

Consumo
mensual
(m3/mes)

7.30

8.50

3.65

19.45

544.60

45.63

7.30

18.25

9.13 DISEÑO CONTRA INCENDIOS


Volumen
Unid. Consumo Tiempo [h]
80.30 Parámetro [m3]

Caudal
L/min 250 2 15

LEVADO + TANQUE BAJO


Hazen Willians
140

Q/A
DE AGUA EN CBBA.
Dimensiones tanque elevado: Largo (m) 2.55

Ancho (m) 2.55

Altura tanque (m) 2.50

Altura útil (m) 2.20

Tirante mínimo de agua (m) 0.55

Volumen útil (m3) 14.31

Elev. Ingreso T.E (m) 2596.10

Elev. Nivel mínimo TE (msnm) 2594.40

Desnivel Nivel Min. Agua - Toma 15 (m) 5.50

Altura de medidor (m) 1.60

Diámetro Tub. Salida TE. DN 50

Caudal Max. Probable (L/s) 3.81

Longitud real Tub. TE - Toma 15 (m) 7.00

Pérdidas Long. Equiv.

Válv. de compuerta abierta DN 50 0.80

Entrada normal DN 50 1.50

1 Codos de 90° DN 50 3.40

1 T salida directa DN 50 2.30

Long. Equiv. pérdidas locales (m) 8.00

Total Long. de cálculo de pérdidas (m) 15.00

Dif. de nivel TE - Piso 15

Nivel mínimo de 2,594.40


agua Elev.
Piso
6.55 Elev. Toma

2,588.90 15 2587.30
2.60
2,586.30 14 2584.70
2.60
2,583.70 13 2582.10
2.60
2,581.10 12 2579.50
2.60
2,578.50 11 2576.90
2.60
2,575.90 10 2574.30
2.60
2,573.30 9 2571.70
2.60
2,570.70 8 2569.10
2.60
2,568.10 7 2566.50
2.60
2,565.50 6 2563.90
2.60
2,562.90 5 2561.30
2.60
2,560.30 4 2558.70
2.60
2,557.70 3 2556.10
2.60
2,555.10 2 2553.50
3.50
2,551.60 1 2550.00
5.00
Sótano 2545.00
2,550.10 2549.00
Red pública

Tabla 1.8. Unidades de gasto. Edif. Multifamiliar

Tipo de artefactos sanitarios Unidades de


Unidades de descarga
descarga agua agua
fría caliente

Inodoro con
tanque de de 13 L/descarga
descarga
3

Lavamanos Convencional 0.4 0.4

Ducha Convencional 1.5 1.5


Tina con ducha Convencional 2.6 2.6

Lavandería Convencional 0.8 0.8

Lavaplatos
exclusivo Convencional 2 2
Cálculo de red de distribución. Instalación sanitaria. Piso 15

Ga

0.00 < UG <100

100 ≤ UG ≤ 500

500 ≤ UG ≤ 1 000

Montante/ Unidades de Gasto


Tramo Qmáx.Prob. (L/s) DN (mm)
Columna
Por piso Acum.

TE - 15 28.00 426.40 3.81 60


15 - 14 28.00 398.40 3.62 50

14 - 13 28.00 370.40 3.43 40

13 - 12 28.00 342.40 3.24 40

12 - 11 28.00 314.40 3.04 40

11 - 10 28.00 286.40 2.85 40

10 - 9 28.00 258.40 2.65 40

9-8 28.00 230.40 2.46 40


1
8-7 28.00 202.40 2.26 40

7-6 28.00 174.40 2.06 40

6-5 28.00 146.40 1.87 40

5-4 28.00 118.40 1.67 40

4-3 28.00 90.40 1.44 40

3-2 28.00 62.40 1.17 20

2-1 25.20 34.40 0.76 20

1- Sótano 9.20 9.20 0.28 20

Unidades de gasto. Tabla 1.8 RENISDA. EDIF. MULTIFAMILIAR

Descripción Baño Padres Baño Hijos Baño visitas Baño empleada


Departamento tipo de
120[m2] Du +B + L +I Du + L + I L+I Du+L+I

Departamento tipo.
Unidades de gasto, agua
fría 6.00 4.90 3.40 4.90

Departamento tipo.
Unidades de gasto, agua
caliente 3.00 1.90

TOTAL GENERAL Unidades de gasto por departamento

Área comercial
No Unid.
Uso No personas de Sanitarias. Tabla
Tasa de ocupación Tabla Sup. Área máxima 2,2;
1.1 [personas/m2] comercial [m2] ocupación pag. 93

Locales comerciales 2.5 300.00 750 2

Unidades de gasto Tabla


1,8, Edif. Comerciales

Total Unidades de gasto


Piletas de
Sótano servicio

Parkeo sin lavado 4

Unidades de gasto 9.2


Gastos Máximos Probables (L/s)

QMP (L/s) = 0.083373 + 0.022533 x UG - 8.31E-5xUG²

QMP (L/s) = 0.814228 + 0.007263x UG - 5.55E-7xUG²

QMP (L/S) = 1,501666+0.005683xUG

V2/2g 0.159678899

Elev. Piezométrica
Velocidad Longitud (m) Pérdida de carga tramo (msnm)
(m/s)
Real Equiv. Total Unit. Total
(mm/m) (mca) Inicial

1.35 7.00 8.00 15.00 34 0.50 2,594.40


1.84 2.63 2.30 4.93 74 0.37 2,593.90

2.73 2.63 2.2 4.83 199 0.96 2,593.53

2.58 2.63 2.2 4.83 179 0.86 2,592.57

2.42 2.63 2.2 4.83 160 0.77 2,591.71

2.27 2.63 2.2 4.83 141 0.68 2,590.93

2.11 2.63 0.9 3.53 124 0.44 2,590.25

1.96 2.63 0.9 3.53 107 0.38 2,589.82

1.80 2.63 0.9 3.53 92 0.33 2,589.44

1.64 2.63 0.6 3.23 78 0.25 2,589.11

1.48 2.63 0.9 3.53 65 0.23 2,588.86

1.33 2.63 0.9 3.53 52 0.18 2,588.63

1.15 2.63 0.9 3.53 40 0.14 2,588.45

3.71 2.63 0.9 3.53 788 2.78 2,588.31

2.42 3.50 0.9 4.40 357 1.57 2,585.52

0.90 5.00 57.65878375

A. EDIF. MULTIFAMILIAR

Lavadora
Cocina Lavandería Pileta de lavado Grifo de patio Eléctrica TOTAL U.G.

Lp Lv Lv Gr Le

2.00 1.9 23.10

4.9

de gasto por departamento 28.00


Varones Varones Mujeres Mujeres
Inodoros Lavamanos Inodoros Lavamanos

2 2 2 2

11 1.6 11 1.6

25.2
Elev. Piezométrica Elev. geométrica tramo Presión dinámica
tramo (msnm) (msnm) (mca)

Final Inicial Final Inicial Final

2,593.90 2,594.40 2,588.90 0.00 5.00


2,593.53 2,588.90 2586.27 5.00 7.26

2,592.57 2,586.27 2,583.70 7.26 8.87

2,591.71 2,583.70 2,581.10 8.87 10.61

2,590.93 2,581.10 2,578.50 10.61 12.43

2,590.25 2,578.50 2,575.90 12.43 14.35

2,589.82 2,575.90 2,573.30 14.35 16.52

2,589.44 2,573.30 2,570.70 16.52 18.74

2,589.11 2,570.70 2,568.10 18.74 21.01

2,588.86 2,568.10 2,565.50 21.01 23.36

2,588.63 2,565.50 2,562.90 23.36 25.73

2,588.45 2,562.90 2,560.30 25.73 28.15

2,588.31 2,560.30 2,557.70 28.15 30.61

2,585.52 2,557.70 2,555.10 30.61 30.42

2,583.95 2,555.10 2,551.60 30.42 32.35

Sótano
Dimensiones tanque elevado: Largo (m) 3
Ancho (m) 2
Alto (m) 1.65
Altura útil (m) 1.4
Tirante mínimo de agua (m) 0.35
Volumen útil (m3) 8.4

Cálculo de red de distribución. Insta

Elev. Piso 15 (msnm) 2587.30


Perdida de carga medidor DN 25 (mca) 1.00
Perdida de carga medidor DN 20 (mca) 3.00
Pérdida local de medidor adoptado 1.00
Elev. Medidor de agua (h=1.6 m) 2588.90

28.00

Unidades de Gasto Qmáx.Prob. DN (mm) Velocidad Longitud (m)


Descripción Tramo (L/s) (m/s)
Real
Artef. Acum.
C1- M 28.00 0.65 25 1.32 0.50
M - 10 28.00 0.65 25 1.32 2.60
10 - 5 15.80 0.42 25 0.85 5.30
5-6 9.80 0.30 20 0.94 1.80
10 - 11 12.20 0.35 20 1.10 2.60
11 - 12 8.30 0.26 20 0.84 0.50
5-2 6.00 0.22 20 0.69 2.10
1.5 2-1 B +D 2.60 0.14 20 0.45 7.20
Baño Padres 2 - 3 3.40 0.16 20 0.51 0.60
0.75 3 - 3' L 0.4 0.09 20 0.29 0.90
3 3- 4 I 3.0 0.15 20 0.48 1.20
6-7 4.90 0.19 20 0.61 6.40
1.5 7 - 7' D 1.50 0.12 20 0.37 2.10
Baño hijos 7-8 3.4 0.16 20 0.51 0.70
3 8 - 8' I 3.0 0.15 20 0.48 0.40
0.75 8-9 L 0.4 0.09 20 0.29 1.50
6 - 6' 4.90 0.19 20 0.61 1.60
6' - C1 4.90 0.19 20 0.61 1.60
C1 - C2 3.00 0.15 20 0.48 0.50
1.5 C2 - 1 D 2.60 0.14 20 0.45 3.40
Agua caliente
0.75 C2 - C3' L 0.4 0.09 15 0.52 2.10
C1 - C4 1.90 0.13 20 0.40 7.70
1.5 C4 - 7' D 1.50 0.12 20 0.37 2.10
0.75 C4 - C9 L 0.4 0.09 15 0.52 2.20
11 - 15 3.9 0.17 20 0.54 5.10
Cocina,
3 Lavandería 15 - 15' LE 1.9 0.13 20 0.40 0.90
2 15 - 16 Lp 2.0 0.13 20 0.41 8.80
12 - 17 4.9 0.19 20 0.61 2.40
0.75 17 - 17' L 0.4 0.09 20 0.29 0.90
Baño
empleada 17 - 18 4.5 0.18 20 0.58 0.70
3 18 - 18' I 3.0 0.15 20 0.48 0.40
1.5 18 - 19 D 1.50 0.12 20 0.37 3.00
12 - 13 3.4 0.16 15 0.90 0.70
Baño
3 visitas 13 - 13' I 3.0 0.15 15 0.85 0.40
0.75 13 - 14 L 0.4 0.09 15 0.52 1.80
29.00 28.00
-3% 4.90
ulo de red de distribución. Instalación sanitaria. Piso 15

QMP (L/S) = 0.083373 + 0.022533 x UG - 8.31E-5xUG²

Elev. Piezométrica Elev. geométrica tramo


Longitud (m) Pérdida de carga tramo (msnm) (msnm)
Perdidas
menores Total Unit. Total
(mm/m) (mca) Inicial Final Inicial Final
0.075 0.58 90 1.05 2,593.90 2,592.84 2,588.90 2,588.90
0.39 2.99 90 0.27 2,592.84 2,592.57 2,588.90 2587.30
0.795 6.10 40 0.24 2,592.57 2,592.33 2,587.30 2,587.30
0.27 2.07 62 0.13 2,592.33 2,592.20 2,587.30 2,587.30
0.39 2.99 83 0.25 2,592.57 2,592.33 2,587.30 2,587.30
0.075 0.58 51 0.03 2,592.33 2,592.30 2,587.30 2,587.30
0.315 2.42 35 0.08 2,592.33 2,592.25 2,587.30 2,587.30
1.08 8.28 16 0.13 2,592.25 2,592.12 2,587.30 2,589.40
0.09 0.69 20 0.01 2,592.25 2,592.23 2,587.30 2,587.30
0.135 1.04 7 0.01 2,592.23 2,592.23 2,587.30 2,588.20
0.18 1.38 18 0.02 2,592.23 2,592.21 2,587.30 2,587.70
0.96 7.36 28 0.21 2,592.20 2,592.00 2,587.30 2,587.30
0.315 2.42 11 0.03 2,592.00 2,591.97 2,587.30 2,589.40
0.105 0.81 20 0.02 2,592.00 2,591.98 2,587.30 2,587.30
0.06 0.46 18 0.01 2,591.98 2,591.97 2,587.30 2,587.70
0.225 1.73 7 0.01 2,591.98 2,591.97 2,587.30 2,588.20
0.24 1.84 28 0.05 2,592.20 2,592.15 2,587.30 2,587.30
0.24 1.84 28 0.05 2,592.15 2,592.10 2,587.30 2,587.30
0.075 0.58 18 0.01 2,592.10 2,592.09 2,587.30 2,587.30
0.51 3.91 16 0.06 2,592.09 2,592.03 2,587.30 2,589.40
0.315 2.42 29 0.07 2,592.09 2,592.02 2,587.30 2,588.20
1.155 8.86 13 0.11 2,592.10 2,591.98 2,587.30 2,587.30
0.315 2.42 11 0.03 2,591.98 2,591.96 2,587.30 2,589.40
0.33 2.53 29 0.07 2,591.98 2,591.91 2,587.30 2,588.20
0.765 5.87 22 0.13 2,592.33 2,592.19 2,587.30 2,587.30
0.135 1.04 13 0.01 2,592.19 2,592.18 2,587.30 2,588.20
1.32 10.12 13 0.13 2,592.19 2,592.06 2,587.30 2,588.20
0.36 2.76 28 0.08 2,592.30 2,592.22 2,587.30 2,587.30
0.135 1.04 7 0.01 2,592.22 2,592.21 2,587.30 2,588.20
0.105 0.81 26 0.02 2,592.22 2,592.20 2,587.30 2,587.30
0.06 0.46 18 0.01 2,592.20 2,592.19 2,587.30 2,587.70
0.45 3.45 11 0.04 2,592.20 2,592.16 2,587.30 2,589.40
0.105 0.81 80 0.06 2,592.30 2,592.23 2,587.30 2,587.30
0.06 0.46 72 0.03 2,592.23 2,592.20 2,587.30 2,587.70
0.27 2.07 29 0.06 2,592.23 2,592.17 2,587.30 2,588.20
Presión dinámica
(mca)

Inicial Final
5.00 3.94
3.94 5.27
5.27 5.03
5.03 4.90
5.27 5.03
5.03 5.00
5.03 4.95
4.95 2.72
4.95 4.93
4.93 4.03
4.93 4.51
4.90 4.70
4.70 2.57
4.70 4.68
4.68 4.27
4.68 3.77
4.90 4.85
4.85 4.80
4.80 4.79
4.79 2.63
4.79 3.82
4.80 4.68
4.68 2.56
4.68 3.71
5.03 4.89
4.89 3.98
4.89 3.86
5.00 4.92
4.92 4.01
4.92 4.90
4.90 4.49
4.90 2.76
5.00 4.93
4.93 4.50
4.93 3.97
Dimensiones tanque elevado: Largo (m) 3
Ancho (m) 2
Alto (m) 1.65
Altura útil (m) 1.4
Tirante mínimo de agua (m) 0.35
Volumen útil (m3) 8.4

Cálculo de red de distribución. Instalació

Elev. Piso 14 (msnm) 2584.70


Perdida de carga medidor DN 25 (mca) 1.00
Perdida de carga medidor DN 20 (mca) 3.00
Pérdida local de medidor adoptado 1.00
Elev. Medidor de agua (h=1.6 m) 2586.30

Unidades de Gasto Qmáx.Pro DN (mm) Velocidad Longitud (m)


Descripción Tramo b. (L/s) (m/s)
Real
Artef. Acum.
C1- M 24.90 0.59 25 1.21 0.50
M - 10 24.90 0.59 20 1.89 2.60
10 - 5 13.60 0.37 20 1.19 5.30
5-6 8.70 0.27 20 0.87 1.80
10 - 11 11.30 0.33 20 1.04 2.60
11 - 12 8.50 0.27 20 0.86 0.50
5-2 4.90 0.19 15 1.09 2.10
2-1 D 1.50 0.12 15 0.66 7.20
Baño Padres 2 - 3 3.40 0.16 15 0.90 0.60
3 - 3' L 0.4 0.09 15 0.52 0.90
3- 4 I 3.0 0.15 15 0.85 1.20
6-7 4.90 0.19 15 1.09 6.40
7 - 7' D 1.50 0.12 15 0.66 2.10
Baño hijos 7-8 3.4 0.16 15 0.90 0.70
8 - 8' I 3.0 0.15 15 0.85 0.40
8-9 L 0.4 0.09 15 0.52 1.50
6 - 6' 3.80 0.17 15 0.95 1.60
6' - C1 3.80 0.17 15 0.95 1.60
C1 - C2 1.90 0.13 15 0.71 0.50
C2 - 1 D 1.50 0.12 15 0.66 3.40
Agua caliente
C2 - C3' L 0.4 0.09 15 0.52 2.10
C1 - C4 1.90 0.13 15 0.71 7.70
C4 - 7' D 1.50 0.12 15 0.66 2.10
C4 - C9 L 0.4 0.09 15 0.52 2.20
11 - 15 2.8 0.15 15 0.83 5.10
Cocina,
Lavandería 15 - 15' LE 0.8 0.10 15 0.57 0.90
15 - 16 Lp 2.0 0.13 15 0.72 8.80
12 - 17 5.0 0.19 15 1.10 2.40
17 - 17' L 0.5 0.09 15 0.54 0.90
Baño
empleada 17 - 18 4.5 0.18 15 1.04 0.70
18 - 18' I 3.0 0.15 15 0.85 0.40
18 - 19 D 1.50 0.12 15 0.66 3.00
12 - 13 3.5 0.16 15 0.91 0.70
Baño
visitas 13 - 13' I 3.0 0.15 15 0.85 0.40
13 - 14 L 0.5 0.09 15 0.54 1.80
lo de red de distribución. Instalación sanitaria. Piso 15

QMP (L/S) = 0.083373 + 0.022533 x UG - 8.31E-5xUG²

Elev. Piezométrica Elev. geométrica tramo Presión dinámica


Longitud (m) Pérdida de carga tramo (msnm) (msnm) (mca)

Equiv. Total Unit. Total


(mm/m) (mca) Inicial Final Inicial Final Inicial
0.075 0.58 76 1.04 2,593.53 2,592.49 2,586.30 2,586.30 7.23
0.39 2.99 226 0.67 2,592.49 2,591.81 2,586.30 2584.70 6.19
0.795 6.10 96 0.59 2,591.81 2,591.22 2,584.70 2,584.70 7.11
0.27 2.07 54 0.11 2,591.22 2,591.11 2,584.70 2,584.70 6.52
0.39 2.99 75 0.22 2,591.81 2,591.59 2,584.70 2,584.70 7.11
0.075 0.58 52 0.03 2,591.59 2,591.56 2,584.70 2,584.70 6.89
0.315 2.42 113 0.27 2,591.22 2,590.95 2,584.70 2,584.70 6.52
1.08 8.28 45 0.38 2,590.95 2,590.57 2,584.70 2,586.80 6.25
0.09 0.69 80 0.06 2,590.95 2,590.89 2,584.70 2,584.70 6.25
0.135 1.04 29 0.03 2,590.89 2,590.86 2,584.70 2,585.60 6.19
0.18 1.38 72 0.10 2,590.89 2,590.80 2,584.70 2,585.10 6.19
0.96 7.36 113 0.83 2,591.11 2,590.28 2,584.70 2,584.70 6.41
0.315 2.42 45 0.11 2,590.28 2,590.17 2,584.70 2,586.80 5.58
0.105 0.81 80 0.06 2,590.28 2,590.21 2,584.70 2,584.70 5.58
0.06 0.46 72 0.03 2,590.21 2,590.18 2,584.70 2,585.10 5.51
0.225 1.73 29 0.05 2,590.21 2,590.16 2,584.70 2,585.60 5.51
0.24 1.84 89 0.16 2,591.11 2,590.95 2,584.70 2,584.70 6.41
0.24 1.84 89 0.16 2,590.95 2,590.79 2,584.70 2,584.70 6.25
0.075 0.58 52 0.03 2,590.79 2,590.76 2,584.70 2,584.70 6.09
0.51 3.91 45 0.18 2,590.76 2,590.58 2,584.70 2,586.80 6.06
0.315 2.42 29 0.07 2,590.76 2,590.69 2,584.70 2,585.60 6.06
1.155 8.86 52 0.46 2,590.79 2,590.33 2,584.70 2,584.70 6.09
0.315 2.42 45 0.11 2,590.33 2,590.22 2,584.70 2,586.80 5.63
0.33 2.53 29 0.07 2,590.33 2,590.25 2,584.70 2,585.60 5.63
0.765 5.87 68 0.40 2,591.59 2,591.19 2,584.70 2,584.70 6.89
0.135 1.04 35 0.04 2,591.19 2,591.15 2,584.70 2,585.60 6.49
1.32 10.12 54 0.54 2,591.19 2,590.64 2,584.70 2,585.60 6.49
0.36 2.76 116 0.32 2,591.56 2,591.24 2,584.70 2,584.70 6.86
0.135 1.04 31 0.03 2,591.24 2,591.21 2,584.70 2,585.60 6.54
0.105 0.81 104 0.08 2,591.24 2,591.15 2,584.70 2,584.70 6.54
0.06 0.46 72 0.03 2,591.15 2,591.12 2,584.70 2,585.10 6.45
0.45 3.45 45 0.16 2,591.15 2,591.00 2,584.70 2,586.80 6.45
0.105 0.81 82 0.07 2,591.56 2,591.49 2,584.70 2,584.70 6.86
0.06 0.46 72 0.03 2,591.49 2,591.46 2,584.70 2,585.10 6.79
0.27 2.07 31 0.06 2,591.49 2,591.43 2,584.70 2,585.60 6.79
Presión dinámica
(mca)

Final
6.19
7.11
6.52
6.41
6.89
6.86
6.25
3.77
6.19
5.26
5.70
5.58
3.37
5.51
5.08
4.56
6.25
6.09
6.06
3.78
5.09
5.63
3.42
4.65
6.49
5.55
5.04
6.54
5.61
6.45
6.02
4.20
6.79
6.36
5.83
Dimensiones tanque elevado: Largo (m) 3
Ancho (m) 2
Alto (m) 1.65
Altura útil (m) 1.4
Tirante mínimo de agua (m) 0.35
Volumen útil (m3) 8.4

Cálculo de red de distribución. Instalació

Elev. Piso 5 (msnm) 2561.30


Perdida de carga medidor DN 25 (mca) 1.00
Perdida de carga medidor DN 20 (mca) 3.00
Pérdida local de medidor adoptado 3.00
Elev. Medidor de agua (h=1.6 m) 2562.90

Unidades de Gasto Qmáx.Pro DN (mm) Velocidad Longitud (m)


Descripción Tramo b. (L/s) (m/s)
Real
Artef. Acum.
C1- M 24.90 0.59 20 1.89 0.50
M - 10 24.90 0.59 20 1.89 2.60
10 - 5 13.60 0.37 15 2.12 5.30
5-6 8.70 0.27 15 1.55 1.80
10 - 11 11.30 0.33 15 1.85 2.60
11 - 12 8.50 0.27 15 1.52 0.50
5-2 4.90 0.19 15 1.09 2.10
2-1 D 1.50 0.12 15 0.66 7.20
Baño Padres 2 - 3 3.40 0.16 15 0.90 0.60
3 - 3' L 0.4 0.09 15 0.52 0.90
3- 4 I 3.0 0.15 15 0.85 1.20
6-7 4.90 0.19 15 1.09 6.40
7 - 7' D 1.50 0.12 15 0.66 2.10
Baño hijos 7-8 3.4 0.16 15 0.90 0.70
8 - 8' I 3.0 0.15 15 0.85 0.40
8-9 L 0.4 0.09 15 0.52 1.50
6 - 6' 3.80 0.17 15 0.95 1.60
6' - C1 3.80 0.17 15 0.95 1.60
C1 - C2 1.90 0.13 15 0.71 0.50
C2 - 1 D 1.50 0.12 15 0.66 3.40
Agua caliente
C2 - C3' L 0.4 0.09 15 0.52 2.10
C1 - C4 1.90 0.13 15 0.71 7.70
C4 - 7' D 1.50 0.12 15 0.66 2.10
C4 - C9 L 0.4 0.09 15 0.52 2.20
11 - 15 2.8 0.15 15 0.83 5.10
Cocina,
Lavandería 15 - 15' LE 0.8 0.10 15 0.57 0.90
15 - 16 Lp 2.0 0.13 15 0.72 8.80
12 - 17 5.0 0.19 15 1.10 2.40
17 - 17' L 0.5 0.09 15 0.54 0.90
Baño
empleada 17 - 18 4.5 0.18 15 1.04 0.70
18 - 18' I 3.0 0.15 15 0.85 0.40
18 - 19 D 1.50 0.12 15 0.66 3.00
12 - 13 3.5 0.16 15 0.91 0.70
Baño
visitas 13 - 13' I 3.0 0.15 15 0.85 0.40
13 - 14 L 0.5 0.09 15 0.54 1.80
ulo de red de distribución. Instalación sanitaria. Piso 5

QMP (L/S) = 0.083373 + 0.022533 x UG - 8.31E-5xUG²

Elev. Piezométrica Elev. geométrica tramo Presión dinámica


Longitud (m) Pérdida de carga tramo (msnm) (msnm) (mca)

Equiv. Total Unit. Total


(mm/m) (mca) Inicial Final Inicial Final Inicial
0.075 0.58 226 3.13 2,588.63 2,585.50 2,562.90 2,562.90 25.73
0.39 2.99 226 0.67 2,585.50 2,584.83 2,562.90 2561.30 22.60
0.795 6.10 391 2.38 2,584.83 2,582.45 2,561.30 2,561.30 23.53
0.27 2.07 218 0.45 2,582.45 2,582.00 2,561.30 2,561.30 21.15
0.39 2.99 305 0.91 2,584.83 2,583.92 2,561.30 2,561.30 23.53
0.075 0.58 212 0.12 2,583.92 2,583.80 2,561.30 2,561.30 22.62
0.315 2.42 113 0.27 2,582.45 2,582.17 2,561.30 2,561.30 21.15
1.08 8.28 45 0.38 2,582.17 2,581.80 2,561.30 2,563.40 20.87
0.09 0.69 80 0.06 2,582.17 2,582.12 2,561.30 2,561.30 20.87
0.135 1.04 29 0.03 2,582.12 2,582.09 2,561.30 2,562.20 20.82
0.18 1.38 72 0.10 2,582.12 2,582.02 2,561.30 2,561.70 20.82
0.96 7.36 113 0.83 2,582.00 2,581.16 2,561.30 2,561.30 20.70
0.315 2.42 45 0.11 2,581.16 2,581.05 2,561.30 2,563.40 19.86
0.105 0.81 80 0.06 2,581.16 2,581.10 2,561.30 2,561.30 19.86
0.06 0.46 72 0.03 2,581.10 2,581.06 2,561.30 2,561.70 19.80
0.225 1.73 29 0.05 2,581.10 2,581.05 2,561.30 2,562.20 19.80
0.24 1.84 89 0.16 2,582.00 2,581.83 2,561.30 2,561.30 20.70
0.24 1.84 89 0.16 2,581.83 2,581.67 2,561.30 2,561.30 20.53
0.075 0.58 52 0.03 2,581.67 2,581.64 2,561.30 2,561.30 20.37
0.51 3.91 45 0.18 2,581.64 2,581.46 2,561.30 2,563.40 20.34
0.315 2.42 29 0.07 2,581.64 2,581.57 2,561.30 2,562.20 20.34
1.155 8.86 52 0.46 2,581.67 2,581.21 2,561.30 2,561.30 20.37
0.315 2.42 45 0.11 2,581.21 2,581.10 2,561.30 2,563.40 19.91
0.33 2.53 29 0.07 2,581.21 2,581.13 2,561.30 2,562.20 19.91
0.765 5.87 68 0.40 2,583.92 2,583.52 2,561.30 2,561.30 22.62
0.135 1.04 35 0.04 2,583.52 2,583.48 2,561.30 2,562.20 22.22
1.32 10.12 54 0.54 2,583.52 2,582.97 2,561.30 2,562.20 22.22
0.36 2.76 116 0.32 2,583.80 2,583.48 2,561.30 2,561.30 22.50
0.135 1.04 31 0.03 2,583.48 2,583.44 2,561.30 2,562.20 22.18
0.105 0.81 104 0.08 2,583.48 2,583.39 2,561.30 2,561.30 22.18
0.06 0.46 72 0.03 2,583.39 2,583.36 2,561.30 2,561.70 22.09
0.45 3.45 45 0.16 2,583.39 2,583.24 2,561.30 2,563.40 22.09
0.105 0.81 82 0.07 2,583.80 2,583.73 2,561.30 2,561.30 22.50
0.06 0.46 72 0.03 2,583.73 2,583.70 2,561.30 2,561.70 22.43
0.27 2.07 31 0.06 2,583.73 2,583.67 2,561.30 2,562.20 22.43
Presión dinámica
(mca)

Final
22.60
23.53
21.15
20.70
22.62
22.50
20.87
18.40
20.82
19.89
20.32
19.86
17.65
19.80
19.36
18.85
20.53
20.37
20.34
18.06
19.37
19.91
17.70
18.93
22.22
21.28
20.77
22.18
21.24
22.09
21.66
19.84
22.43
22.00
21.47
Dimensiones tanque elevado: Largo (m) 3
Ancho (m) 2
Alto (m) 1.65
Altura útil (m) 1.4
Tirante mínimo de agua (m) 0.35
Volumen útil (m3) 8.4

Cálculo de red de distribución. Instalació

Elev. Piso 5 (msnm) 2550.00


Perdida de carga medidor DN 25 (mca) 1.00
Perdida de carga medidor DN 20 (mca) 3.00
Pérdida local de medidor adoptado DN 15 5.00
Elev. Medidor de agua (h=1.6 m) 2551.60

Unidades de Gasto Qmáx.Pro DN (mm) Velocidad Longitud (m)


Descripción Tramo b. (L/s) (m/s)
Real
Artef. Acum.
C1- M 24.90 0.59 20 1.89 0.50
M - 10 24.90 0.59 20 1.89 2.60
10 - 5 13.60 0.37 15 2.12 5.30
5-6 8.70 0.27 15 1.55 1.80
10 - 11 11.30 0.33 15 1.85 2.60
11 - 12 8.50 0.27 15 1.52 0.50
5-2 4.90 0.19 15 1.09 2.10
2-1 D 1.50 0.12 15 0.66 7.20
Baño Padres 2 - 3 3.40 0.16 15 0.90 0.60
3 - 3' L 0.4 0.09 15 0.52 0.90
3- 4 I 3.0 0.15 15 0.85 1.20
6-7 4.90 0.19 15 1.09 6.40
7 - 7' D 1.50 0.12 15 0.66 2.10
Baño hijos 7-8 3.4 0.16 15 0.90 0.70
8 - 8' I 3.0 0.15 15 0.85 0.40
8-9 L 0.4 0.09 15 0.52 1.50
6 - 6' 3.80 0.17 15 0.95 1.60
6' - C1 3.80 0.17 15 0.95 1.60
C1 - C2 1.90 0.13 15 0.71 0.50
C2 - 1 D 1.50 0.12 15 0.66 3.40
Agua caliente
C2 - C3' L 0.4 0.09 15 0.52 2.10
C1 - C4 1.90 0.13 15 0.71 7.70
C4 - 7' D 1.50 0.12 15 0.66 2.10
C4 - C9 L 0.4 0.09 15 0.52 2.20
11 - 15 2.8 0.15 15 0.83 5.10
Cocina,
Lavandería 15 - 15' LE 0.8 0.10 15 0.57 0.90
15 - 16 Lp 2.0 0.13 15 0.72 8.80
12 - 17 5.0 0.19 15 1.10 2.40
17 - 17' L 0.5 0.09 15 0.54 0.90
Baño
empleada 17 - 18 4.5 0.18 15 1.04 0.70
18 - 18' I 3.0 0.15 15 0.85 0.40
18 - 19 D 1.50 0.12 15 0.66 3.00
12 - 13 3.5 0.16 15 0.91 0.70
Baño
visitas 13 - 13' I 3.0 0.15 15 0.85 0.40
13 - 14 L 0.5 0.09 15 0.54 1.80
lo de red de distribución. Instalación sanitaria. Piso 15

QMP (L/S) = 0.083373 + 0.022533 x UG - 8.31E-5xUG²

Elev. Piezométrica Elev. geométrica tramo Presión dinámica


Longitud (m) Pérdida de carga tramo (msnm) (msnm) (mca)

Equiv. Total Unit. Total


(mm/m) (mca) Inicial Final Inicial Final Inicial
0.075 0.58 226 5.13 2,583.95 2,578.82 2,551.60 2,551.60 32.35
0.39 2.99 226 0.67 2,578.82 2,578.15 2,551.60 2550.00 27.22
0.795 6.10 391 2.38 2,578.15 2,575.77 2,550.00 2,550.00 28.15
0.27 2.07 218 0.45 2,575.77 2,575.32 2,550.00 2,550.00 25.77
0.39 2.99 305 0.91 2,578.15 2,577.24 2,550.00 2,550.00 28.15
0.075 0.58 212 0.12 2,577.24 2,577.12 2,550.00 2,550.00 27.24
0.315 2.42 113 0.27 2,575.77 2,575.49 2,550.00 2,550.00 25.77
1.08 8.28 45 0.38 2,575.49 2,575.12 2,550.00 2,552.10 25.49
0.09 0.69 80 0.06 2,575.49 2,575.44 2,550.00 2,550.00 25.49
0.135 1.04 29 0.03 2,575.44 2,575.41 2,550.00 2,550.90 25.44
0.18 1.38 72 0.10 2,575.44 2,575.34 2,550.00 2,550.40 25.44
0.96 7.36 113 0.83 2,575.32 2,574.48 2,550.00 2,550.00 25.32
0.315 2.42 45 0.11 2,574.48 2,574.37 2,550.00 2,552.10 24.48
0.105 0.81 80 0.06 2,574.48 2,574.42 2,550.00 2,550.00 24.48
0.06 0.46 72 0.03 2,574.42 2,574.38 2,550.00 2,550.40 24.42
0.225 1.73 29 0.05 2,574.42 2,574.37 2,550.00 2,550.90 24.42
0.24 1.84 89 0.16 2,575.32 2,575.15 2,550.00 2,550.00 25.32
0.24 1.84 89 0.16 2,575.15 2,574.99 2,550.00 2,550.00 25.15
0.075 0.58 52 0.03 2,574.99 2,574.96 2,550.00 2,550.00 24.99
0.51 3.91 45 0.18 2,574.96 2,574.78 2,550.00 2,552.10 24.96
0.315 2.42 29 0.07 2,574.96 2,574.89 2,550.00 2,550.90 24.96
1.155 8.86 52 0.46 2,574.99 2,574.53 2,550.00 2,550.00 24.99
0.315 2.42 45 0.11 2,574.53 2,574.42 2,550.00 2,552.10 24.53
0.33 2.53 29 0.07 2,574.53 2,574.46 2,550.00 2,550.90 24.53
0.765 5.87 68 0.40 2,577.24 2,576.84 2,550.00 2,550.00 27.24
0.135 1.04 35 0.04 2,576.84 2,576.80 2,550.00 2,550.90 26.84
1.32 10.12 54 0.54 2,576.84 2,576.29 2,550.00 2,550.90 26.84
0.36 2.76 116 0.32 2,577.12 2,576.80 2,550.00 2,550.00 27.12
0.135 1.04 31 0.03 2,576.80 2,576.76 2,550.00 2,550.90 26.80
0.105 0.81 104 0.08 2,576.80 2,576.71 2,550.00 2,550.00 26.80
0.06 0.46 72 0.03 2,576.71 2,576.68 2,550.00 2,550.40 26.71
0.45 3.45 45 0.16 2,576.71 2,576.56 2,550.00 2,552.10 26.71
0.105 0.81 82 0.07 2,577.12 2,577.05 2,550.00 2,550.00 27.12
0.06 0.46 72 0.03 2,577.05 2,577.02 2,550.00 2,550.40 27.05
0.27 2.07 31 0.06 2,577.05 2,576.99 2,550.00 2,550.90 27.05
Presión dinámica
(mca)

Final
27.22
28.15
25.77
25.32
27.24
27.12
25.49
23.02
25.44
24.51
24.94
24.48
22.27
24.42
23.98
23.47
25.15
24.99
24.96
22.68
23.99
24.53
22.32
23.56
26.84
25.90
25.39
26.80
25.86
26.71
26.28
24.46
27.05
26.62
26.09
Diámetro Descarga ( L/min)
Tipo de Artefacto Subramal
DN (mm) NBr NCh NPC

Lavamanos, lavabo, corriente 15 12.0 10.0 9.46


Lavamanos c/ medidor de
caudal (por ciclo)
15 0.95
Lavamanos c/grifo de cierre 15 1.89
automático
Bidét 15 6.0 6.0
Tina de Baño 20 18.0 15.0 19.00
Ducha Corriente DN 100 15 12.0 10.0 9.46

Inodoro c/tanque de descarga 15 9.0 10.0 11.40


Esp.
Inodoro c/válvula de descarga 25 114.0 Fabric. 50-135
Lavaplatos, pileta de cocina 15 15.0 12.0 17.00
Lavandería 15 18.0 15.0 9.50
Máquina de lavar platos 20 18.0 15.40
Máquina de lavar ropa 20 18.0 15.14
Bebedero 15 3.0 5.0 2.84
Urinario c/descarga
contínua/corriente 15 4.5 6.0 5.70
Urinario con válvula de Esp.
descarga 15 9.0 Fabric. 45.42
Grifo de riego 15 20.0 19.00
escarga ( L/min) Presión
Dinamica de
Norma Servicio
RENISDA
Francesa (mca)

6.0 9.46 9.5

0.95
1.89
6.0 1.0
21.0 19.00 1.0
15.0 9.46 1.0 - 2.0

6.0 9.00 0.5 - 1.5

90.0 50-135 1.2 - 6.5


12.0 17.00 0.5
24.0 9.50 1.8
15.40 3.0
15.14 0.5
2.84 2.0

5.70 0.5

30.0 45.42 1.2 - 6.5


42.0 19.0
Artefactos de bajo consumo
Inodoro de bajo consumo 3 - 6 L/descarga

VIVIENDA RESIDENCIAL SISTEMA DIRECTO

Dimensiones terreno
Largo [m] 20.00
Frente [m] 15.00
Superficie terreno [m2] 300.00
Superficies Construida ( m2) 120
No domitorios 3
Superficie de jardines 96
Unidades sanitarias
Baño padres (Tina +D + L + I) 1
Baño hijos (D+L+I) 1
Baño de visitas ( L +I) 1
Lavandería (Lv) 1
Cocina [Lp] 1
Grigfo de riego 2

Caudal máximo probable 5.3

Cota de elevación del inmueble (msnm) 3,875.00


Dotación percápita (L/p.d) 100

CONSUMO DIARIO - NORMA ANTERIOR Norma Anterior RENISDA

Consumo diario doméstico (L) 1,200.00 600.00

Riego de jardines (L/d) 120.00


Total consumo diario (L) 1,200.00 720.00
Total Vol. de almacenamiento, tanque elevado
(previsión de 1 día) m3 1.20 0.72
Dimensiones tanque (m) 1 x 1 x 1.5 1 x 1 x 0.9

Cálculo del rama domiciliario


a) Datos de diseño RENISDA Norma Anterior
Material PVC

Presión mínima disponible en la red pública (mca) 13


Horas de servicio público (hrs) 24
Cota Tub. red pública 3,873.50

b) Presión disponible en la red pública 13.00


Horas de servicio público por día (hrs) 9.00
Ramal al tanque elevado
Tiemmpo de llenado 3.00
Caudal de diseño (L/s) 0.067
DN acometida (mm) 15.000
Velocidad (m/s) 0.38
Medidor DN (mm) 15.000
Pérdidas por medidor 2.000
Long. real (m)Tub. DN 15 a tanque elevado 26.60
Longitud total equivalente (m) 30.59
Cota llegada tanque elevado (m) 3,879.60
Cota piso terminado (m) 3,874.60
Pérdida de carga unitaria (mm/m) DN 15 16.05
Perdidad de carga total (m) 2.49
Cota Piezométrica Inicial (m) 3,886.50
Cota Piezométrica final (m) 3,884.01
Cota tramo inicial (m) 3,873.50
Cota tramo final (m) 3,879.60
Presión inicial (m) 13.00
Presión final (m) 4.41

c) Presión disponible en la red pública 13.00


Horas de servicio público por día (hrs) 2.00
Caudal de diseño (L/s) 0.100
DN acometida (mm) 15
Velocidad (m/s) 0.57
Medidor DN (mm) 15
Pérdidas por medidor (m) 2.00
Pérdida de carga unitaria (mm/m) 33.97
Perdidad de carga total (m) (fricción, localizadas,
medidor) 3.04
Cota Piezométrica Inicial (m) 3,886.50
Cota Piezométrica final (m) 3,883.46
Cota inicial (m) 3,873.50
Cota final (m) 3,879.60
Presión inicial (m) 13.00
Presión final (m) 3.86

Norma Anterior
Presión disponible en la red pública 13.00
Horas de servicio público por día (hrs) 9.00
Ramal al tanque elevado
Tiemmpo de llenado 3.00
Caudal de diseño (L/s) 0.111
DN acometida (mm) 20
Velocidad (m/s) 0.35
Medidor DN (mm) 20.000
Pérdidas por medidor 3.000
Long. real (m)Tub. DN 20 a tanque elevado 26.60
Longitud total equivalente (m) 30.59
Cota llegada tanque elevado (m) 3,879.60
Cota piso terminado (m) 3,874.60
Pérdida de carga unitaria (mm/m) DN 20 10.18
Perdidad de carga total (m) 3.31
Cota Piezométrica Inicial (m) 3,886.50
Cota Piezométrica final (m) 3,883.19
Cota tramo inicial (m) 3,873.50
Cota tramo final (m) 3,879.60
Presión inicial (m) 13.00
Presión final (m) 3.59
Unidades Hunter de Gasto - Viviendas unifamiliares- Tabla 1.8
Unidades de gasto
Ambiente
B +D L I Lp Lv
Baño padres 3 0.8 2.5
Baño hijos 1.5 0.8 2.5
Baño de visitas 0.8 2.5
Lavandería 1.50
Cocina 1.10
Grigfo de riego

Grifo de riego 1 2.5 2.5


TOTAL UNIDADES DE GASTO 10

Diferencia

100%

67%

67%
to
G Total
6.30
4.80
3.30
1.50
1.10
3.60 3.60
20.60
Cálculo de red de distribución. Instalació
Presión en la red (mca) 13.00
Perdida de carga medidor DN 15 (mca) 2.80
Perdida de carga medidor DN 20 (mca) 1.53
Pérdida local de medidor adoptado 1.53

Unidades de Gasto Qmáx.P DN Longitud (m)


Velocidad
Tramo rob. (mm) (m/s)
Artef. Acum. (L/s) Real Equiv.
Red - M 14.20 0.38 20 1.21 6.00 0.9
M-1 14.20 0.38 15 2.15 3.00 0.45
1-9 Lv 1.50 0.17 15 0.96 4.00 0.60
1-2 12.70 0.30 15 1.70 3.00 0.45
2 - 11 3.80 0.17 15 0.96 8.50 1.28
11 - 13 L 0.80 0.15 15 0.85 2.50 0.38
11 - 12 I 3.00 0.15 15 0.85 2.00 0.30
2-3 8.90 0.23 15 1.30 5.00 0.75
3 - 10 Lp 1.10 0.28 15 1.58 4.25 0.64
3 - 15 7.80 0.26 15 1.47 3.00 0.45
15 - 14 Gr 2.50 0.32 15 1.81 7.00 1.05
15 - 4 5.30 0.20 15 1.13 1.50 0.23
4-8 I 3.00 0.15 15 0.85 0.40 0.06
4-5 2.30 0.32 15 1.81 1.50 0.23
5-6 D 1.50 0.16 15 0.91 2.10 0.32
5-7 L 0.80 0.16 15 0.91 4.50 0.68
de distribución. Instalación sanitaria

ongitud (m) Pérdida de carga Cota Piezométrica (m) Cota Tramo (m) Presión (m)
Unit. Total
Total (mm/m) (mca) Inicial Final Inicial Final Inicial Final
6.9 99 2.21 3,886.50 3,884.29 3,873.50 3,874.30 13.00 9.99
3.45 402 1.39 3,884.29 3,882.90 3,874.30 3874.30 9.99 8.60
4.60 91 0.42 3,882.90 3,882.48 3,874.30 3,875.60 8.60 6.88
3.45 259 0.89 3,882.90 3,882.01 3,874.30 3,874.30 8.60 7.71
9.78 91 0.89 3,882.01 3,881.12 3,874.30 3,874.30 7.71 6.82
2.88 72 0.21 3,881.12 3,880.91 3,874.30 3,875.60 6.82 5.31
2.30 72 0.17 3,881.12 3,880.95 3,874.30 3,875.20 6.82 5.75
5.75 159 0.91 3,882.01 3,881.09 3,874.30 3,874.30 7.71 6.79
4.89 228 1.12 3,881.09 3,879.98 3,874.30 3,875.50 6.79 4.48
3.45 199 0.69 3,881.09 3,880.41 3,874.30 3,874.30 6.79 6.11
8.05 292 2.35 3,880.41 3,878.06 3,874.30 3,875.60 6.11 2.46
1.73 122 0.21 3,880.41 3,880.20 3,874.30 3,874.30 6.11 5.90
0.46 72 0.03 3,880.41 3,880.38 3,874.30 3,874.90 6.11 5.48
1.73 292 0.50 3,880.41 3,879.90 3,874.30 3,874.30 6.11 5.60
2.42 81 0.20 3,879.90 3,879.71 3,874.30 3,876.70 5.60 3.01
5.18 81 0.42 3,880.41 3,879.99 3,874.30 3,875.60 6.11 4.39
Superficie terreno (m2) 400
Superficies Construida ( m2) 250
No domitorios 3
Superficie de jardines 90
Consumo percápita (L/p.d) 120
Unidades sanitarias
Un baño padres (B+D+ L + I)
Un baños hijos ( D+L+I)
Un baño visitas (I+L)
Un Grifo de riego (1Gr)
Un baño empleada (I +L+D)
Tasa de ocupación [personas] 2

CONSUMO DIARIO Norma Anterior RENISDA Diferencia

Consumo diario doméstico 1,600 840.00 90%

Riego de jardines (L/d) 180.00

Total consumo diario 1,600.00 1020.00 57%

Total Vol. de almacenamiento, tanque


elevado (previsión de 1 día) m3 1.60 1.02 57%
Dimensiones tanque (m) 1,4 x 1,4 x 1.20 1.00 x 1.00 x 1.20

Volumen adoptado
No días de programación del servicio 3
Volumen adoptado útil [m3] 3.06
Volumen adpotado útil [L] 3,060.00
Unidades Hunter de Gasto
Artefacto No UG-RENISDA Total UG
Baño + Ducha 2 3 6
Lavamanos 4 0.8 3.2
Inodoro (bajo consumo) 4 2.5 10
Lavaplatos 1 1.1 1.1
Lavandería 1 1.5 1.5
Grifo de riego 1 2.5 2.5
TOTAL UNIDADES DE GASTO 24.3
Elevación matriz pública
Elevación medidor
Elevación piso terminado
Presión en la red (mca)
Perdida de carga medidor DN 15 (mca)
Perdida de carga medidor DN 20 (mca)
Perdida de carga medidor DN 25 (mca)

Unidades de Gasto
Ambiente Tramo
Artef. Acum.
Red - M 24.30
M-1 24.30
1-2 18.00
Jardín 2-4 Gr 2.5
2-3 15.50
3-9 14.40
9-5 11.10
1 - 18 6.30
Lavandería 18 - 19 Lv 1.50
18 - 14 4.80
14 - 13 4.00
13 - 20 D 1.50
Baño 13 - 13' I 2.50
empleada 14 -14' L 0.80
9 - 10 3.30
Baño 10 - 10' L 0.80
visitas 10 - 11 I 2.50
Cocina 3- 12 Lp 1.1
5-6 4.80
6 - 6' D 1.50
Baño
hijos 6-7 3.30
7 - 7' L 0.80
7-8 I 2.50
5 - 15 6.30
15 - 16 3.80
Baño
padres 16 - 17 B +D 3.00
15 - 15' I 2.50
16 - 16' L 0.80
Cálculo de red de distribución de agua. Alimentación directa
2673.5
2674.7
2674.9
15.00
dor DN 15 (mca) 5.00
dor DN 20 (mca) 3.00
dor DN 25 (mca) 1.00

Longitud (m) Pérdida de carga


Qmáx.Prob. Velocidad
DN (mm) Unit. Total
(L/s) (m/s)
Real Equiv. Total (mm/m) (mca)
0.59 20 1.88 6.00 0.90 6.9 224 4.54
0.59 20 1.88 6.00 0.90 6.90 224 1.54
0.46 20 1.46 4.00 0.60 4.60 141 0.65
0.32 20 1.02 6.50 0.98 7.48 72 0.54
0.41 20 1.31 4.00 0.60 4.60 114 0.52
0.39 20 1.24 6.00 0.90 6.90 104 0.72
0.32 20 1.02 2.60 0.39 2.99 72 0.22
0.23 20 0.73 14.00 2.10 16.10 39 0.63
0.17 15 0.96 4.00 0.60 4.60 91 0.42
0.19 20 0.60 4.00 0.60 4.60 27 0.13
0.17 15 0.96 6.00 0.90 6.90 91 0.63
0.17 20 0.54 4.10 0.62 4.72 22 0.11
0.15 15 0.85 0.60 0.09 0.69 72 0.05
0.16 15 0.91 1.60 0.24 1.84 81 0.15
0.16 15 0.91 1.50 0.23 1.73 81 0.14
0.16 15 0.91 0.80 0.12 0.92 81 0.07
0.15 15 0.85 1.50 0.23 1.73 72 0.12
0.28 15 1.58 7.00 1.05 8.05 228 1.84
0.19 20 0.60 7.00 1.05 8.05 27 0.22
0.17 20 0.54 2.10 0.32 2.42 22 0.05
0.16 15 0.91 3.00 0.45 3.45 81 0.28
0.16 15 0.91 0.80 0.12 0.92 81 0.07
0.15 15 0.85 1.50 0.23 1.73 72 0.12
0.22 20 0.70 4.00 0.60 4.60 36 0.17
0.17 20 0.54 1.60 0.24 1.84 22 0.04
0.15 20 0.48 6.90 1.04 7.94 18 0.14
0.15 15 0.85 0.30 0.05 0.35 72 0.02
0.16 15 0.91 0.80 0.12 0.92 81 0.07
ntación directa

Cota Piezométrica (m) Cota Tramo (m) Presión (m)

Inicial Final Inicial Final Inicial Final


2,688.50 2,683.96 2,673.50 2,674.70 15.00 9.26
2,683.96 2,682.42 2,674.70 2674.90 9.26 7.52
2,682.42 2,681.77 2,674.90 2,674.90 7.52 6.87
2,681.77 2,681.23 2,674.90 2,675.60 6.87 5.63
2,681.77 2,681.24 2,674.90 2,674.90 6.87 6.34
2,681.24 2,680.53 2,674.90 2,674.90 6.34 5.63
2,681.24 2,681.03 2,674.90 2,674.90 6.34 6.13
2,682.42 2,681.79 2,674.90 2,674.90 7.52 6.89
2,681.79 2,681.37 2,674.90 2,676.00 6.89 5.37
2,681.79 2,681.66 2,674.90 2,674.90 6.89 6.76
2,681.66 2,681.03 2,674.90 2,674.90 6.76 6.13
2,681.03 2,680.93 2,674.90 2,677.00 6.13 3.93
2,681.03 2,680.98 2,674.90 2,675.50 6.13 5.48
2,681.66 2,681.51 2,674.90 2,676.00 6.76 5.51
2,680.53 2,680.39 2,674.90 2,674.90 5.63 5.49
2,680.39 2,680.31 2,674.90 2,676.20 5.49 4.11
2,680.39 2,680.26 2,674.90 2,675.80 5.49 4.46
2,680.53 2,678.69 2,674.90 2,676.00 5.63 2.69
2,681.03 2,680.81 2,674.90 2,674.90 6.13 5.91
2,680.81 2,680.75 2,674.90 2,677.00 5.91 3.75
2,680.81 2,680.53 2,674.90 2,674.90 5.91 5.63
2,680.53 2,680.45 2,674.90 2,675.50 5.63 4.95
2,680.53 2,680.40 2,674.90 2,675.20 5.63 5.20
2,681.03 2,680.86 2,674.90 2,674.90 6.13 5.96
2,680.86 2,680.82 2,674.90 2,674.90 5.96 5.92
2,680.82 2,680.68 2,674.90 2,677.00 5.92 3.68
2,680.86 2,680.84 2,674.90 2,675.20 5.96 5.64
2,680.82 2,680.75 2,674.90 2,675.50 5.92 5.25
Elevación Tub. Salida T.E
Elevación medidor
Elevación piso terminado
Presión en la red (mca)
Perdida de carga medidor DN 15 (mca)
Perdida de carga medidor DN 20 (mca)
Perdida de carga medidor DN 25 (mca)
Pérdida local de medidor adoptado

Unidades de Gasto
Ambiente Tramo
Artef. Acum.
T.E - 1 0.00

1-2 18.00
Jardín 2-4 Gr 2.5
2-3 15.50
3-9 14.40
9-5 11.10
1 - 18 6.30
Lavandería 18 - 19 Lv 1.50
18 - 14 4.80
14 - 13 4.00
13 - 20 D 1.50
Baño 13 - 13' I 2.50
empleada 14 -14' L 0.80
9 - 10 3.30
Baño 10 - 10' L 0.80
visitas 10 - 11 I 2.50
Cocina 3- 12 Lp 1.1
5-6 4.80
6 - 6' D 1.50
Baño
hijos 6-7 3.30
7 - 7' L 0.80
7-8 I 2.50
5 - 15 6.30
15 - 16 3.80
Baño
padres 16 - 17 B +D 3.00
15 - 15' I 2.50
16 - 16' L 0.80
Cálculo de red de distribución de agua. Alimentación directa
2,680.00
2681.2
2674.9
15.00
dor DN 15 (mca) 5.00
dor DN 20 (mca) 3.00
dor DN 25 (mca) 1.00
dor adoptado 0.00

Longitud (m) Pérdida de carga


Qmáx.Prob. Velocidad
DN (mm) Unit. Total
(L/s) (m/s)
Real Equiv. Total (mm/m) (mca)
0 25 0.00 10.00 1.50 11.5 0 0.00

0.46 20 1.46 4.00 0.60 4.60 141 0.65


0.32 20 1.02 6.50 0.98 7.48 72 0.54
0.41 20 1.31 4.00 0.60 4.60 114 0.52
0.39 20 1.24 6.00 0.90 6.90 104 0.72
0.32 20 1.02 2.60 0.39 2.99 72 0.22
0.23 20 0.73 14.00 2.10 16.10 39 0.63
0.17 15 0.96 4.00 0.60 4.60 91 0.42
0.19 20 0.60 4.00 0.60 4.60 27 0.13
0.17 15 0.96 6.00 0.90 6.90 91 0.63
0.17 20 0.54 4.10 0.62 4.72 22 0.11
0.15 15 0.85 0.60 0.09 0.69 72 0.05
0.16 15 0.91 1.60 0.24 1.84 81 0.15
0.16 15 0.91 1.50 0.23 1.73 81 0.14
0.16 15 0.91 0.80 0.12 0.92 81 0.07
0.15 15 0.85 1.50 0.23 1.73 72 0.12
0.28 15 1.58 7.00 1.05 8.05 228 1.84
0.19 20 0.60 7.00 1.05 8.05 27 0.22
0.17 20 0.54 2.10 0.32 2.42 22 0.05
0.16 15 0.91 3.00 0.45 3.45 81 0.28
0.16 15 0.91 0.80 0.12 0.92 81 0.07
0.15 15 0.85 1.50 0.23 1.73 72 0.12
0.22 20 0.70 4.00 0.60 4.60 36 0.17
0.17 20 0.54 1.60 0.24 1.84 22 0.04
0.15 20 0.48 6.90 1.04 7.94 18 0.14
0.15 15 0.85 0.30 0.05 0.35 72 0.02
0.16 15 0.91 0.80 0.12 0.92 81 0.07
ntación directa

Cota Piezométrica (m) Cota Tramo (m) Presión (m)

Inicial Final Inicial Final Inicial Final


2,680.00 2,680.00 2,680.00 2,674.90 - 5.10

2,680.00 2,679.35 2,674.90 2,674.90 5.10 4.45


2,679.35 2,678.81 2,674.90 2,675.60 4.45 3.21
2,679.35 2,678.83 2,674.90 2,674.90 4.45 3.93
2,678.83 2,678.11 2,674.90 2,674.90 3.93 3.21
2,678.83 2,678.61 2,674.90 2,674.90 3.93 3.71
2,680.00 2,679.37 2,674.90 2,674.90 5.10 4.47
2,679.37 2,678.95 2,674.90 2,676.00 4.47 2.95
2,679.37 2,679.24 2,674.90 2,674.90 4.47 4.34
2,679.24 2,678.62 2,674.90 2,674.90 4.34 3.72
2,678.62 2,678.51 2,674.90 2,677.00 3.72 1.51
2,678.62 2,678.57 2,674.90 2,675.50 3.72 3.07
2,679.24 2,679.09 2,674.90 2,676.00 4.34 3.09
2,678.11 2,677.97 2,674.90 2,674.90 3.21 3.07
2,677.97 2,677.90 2,674.90 2,676.20 3.07 1.70
2,677.97 2,677.85 2,674.90 2,675.80 3.07 2.05
2,678.11 2,676.27 2,674.90 2,676.00 3.21 0.27
2,678.61 2,678.39 2,674.90 2,674.90 3.71 3.49
2,678.39 2,678.34 2,674.90 2,677.00 3.49 1.34
2,678.39 2,678.11 2,674.90 2,674.90 3.49 3.21
2,678.11 2,678.04 2,674.90 2,675.50 3.21 2.54
2,678.11 2,677.99 2,674.90 2,675.20 3.21 2.79
2,678.61 2,678.45 2,674.90 2,674.90 3.71 3.55
2,678.45 2,678.40 2,674.90 2,674.90 3.55 3.50
2,678.40 2,678.26 2,674.90 2,677.00 3.50 1.26
2,678.45 2,678.42 2,674.90 2,675.20 3.55 3.22
2,678.40 2,678.33 2,674.90 2,675.50 3.50 2.83
Capacidad T.E [L] 500
Ingreso T.E. Elevación 2680.9
Elevación piso terminado 2674.9
Altura de ingreso T.E. 6.00
Elev. Tub. Salida [msnm] 2,680.00

Tubería de alimentación Red Pública - Tanque enterrado

Continuidad del servicio (h) 15

Consumo diario (L) 3,060.00

Presión dinámica mínima en la


red pública mca 15.00

Tiempo de llenado del tanque (h) 3.00


Caudal de alimentación
(L/s),
0.28
Diámetro del ramal de
alimentacción DN 15
Pérdida de carga unitaria por
fricción (mm/m) 233.28
Velocidad (m/s) 1.60
Longitud de tubería, ramal de
alimentación (m) 10.00
Pérdidas localizadas, long.
equivalente 2.50
Long. total equivalente (real más
pérdidas localizadas) 12.50
Pérdidas por fricción y localizadas
(m) 2.92

Pérdidas por medidor DN 20 1.00


Total pérdidas ( fricción,
localizadas más medidor) 3.92
Elevación piezométrica red
pública 2695.00
Elevación de la Tub. de ingreso al
tanque bajo (msnm) 2673.40

Elevación piezométrica Tub.


ingreso al tanque cisterna (msnm) 2691.08

Presión dinámica disponible (m) 17.68


Capacidad T.E. [L]

Características

Máx. No hrs. de bombeo,


RENISDA
No hrs. de bombeo
adoptadas
Consumo diario (L)
Caudal de bombeo (L/s)

Diámetro económicoTub.
impulsión RENISDA (mm),
pág. 156
Diámetro comercial
adoptado DN (mm),
RENISDA
Altura manométrica de
succión, Hs (m)

Altura geométrica de
succión (m), tanque bajo
Pérdidas locales, Long.
Equiv. (m):
Válvula de pié DN 20
2 Codo 90° DN 20
Long. Equivalente,
pérdidas locales por
succión (m)

Long. real de succión (m)


Long. total de succión (m),
real más equiv.
Pérdida de carga unitaria
(mm/m)
Velocidad de flujo (m/s)
Pérdida de carga total en
la succión (m), fricción y
locales
Altura manométrica de
Impulsión,
Hi (m):
Altura geométrica de
impulsión (m)
Pérdidas locales, Long.
Equiv. (m):
1 Llave de paso,
compuerta DN 20
Válvula de retención
DN 20

5 Codos DN 20
Long. Equivalente,
pérdidas locales por
impulsión (m)
Long. real de impulsión
(m)

Longitud total impulsión,


real más equivalente
Pérdida de carga Unit. Tub.
impulsión(mm/m)
Velocidad de flujo (m/s)
Pérdida de carga total en
la impulsión (m).
Altura manométrica de
bombeo
Hb (m)

Eficiencia, conjunto motro


- bomba
Potencia teórica de la
Bomba kw

Coeficiente de mayoración
Potencia de diseño kW
Potencia comercial
adoptada kW
Consumo de energía
kWh / d
Consumo mensual de
energía kWh/mes
Costo Energía Bs / kWh
Costo mensual de energía
(Bs/mes)
Costo Anual Energía
( Bs )
500

RENISDA
2011

6.00

0.25
1,020.00
1.13

30.95

20

10.72

1.00

9.50
1.00

10.50

2.50

13.00

748
3.61

9.72

36.89
6.00

0.20

4.10

6.00

10.30

31.00

41.30

748
3.61

31

47.61

0.50

1.06

1.20
1.27

1.50

0.32

9.66
1.20

11.59

139.10
Previsión de descarga en los hidrantes

Tipo de predio

A
B
C
revisión de descarga en los hidrantes

ipo de predio Descarga (L/min)

Escuelas, residencias, oficinas 250


Fábricas, oficinas comerciales, etc. 500
Depósitos de combustibles, estaciones subterráneas de metro, etc. 900
Tabla 1.6. Unidades de gasto por artefacto s

Viviendas Unifamiliares o de dos


Artefacto Sanitario Deptos.
Unidades Hunter (UH)
Total Fria Caliente
Tina de Baño o Tina con Ducha 4.0 3.0 3.0

Bidet 1.0 0.8 0.8

Lavadora Automática (doméstica) 4.0 3.0 3.0

Máquina de lavar platos Automático (doméstico) 1.5 1.5

Bebedero

Grifo de Riego 2.5 2.5

Grifo de Riego Adicional, por c/ Unid. añadida 1.0 1.0

Lavaplatos o pileta de cocina 1.5 1.1 1.1

Lavandería o pileta de lavado 2.0 1.5 1.5

Lavamanos o Lavatorio 1.0 0.8 0.8

Pileta de Servicio

Ducha individual 2.0 1.5 1.5

Ducha de uso contínuo

Urinario c/Válvula de descarga de 3.75 L

Urinario, c/Válvula de descarga > a 3.75 L

Inodoro c/tanque de descarga de 6 L 2.5 2.5

Inodoro c/ tanque de hidropresión de 6 L 2.5 2.5

Inodoro, c/válvula de descarga de 6 L 5.0 5.0

Inodoro, c/ tanque de descarga de 13 L. 3.0 3.0

Inodoro, c/válvula de descarga de 13 L 7.0 7.0

Tina de Hidromasaje 4.0 3.0 3.0

**** Fuente: National Standard Plumbing Code 2006


Unidades de gasto por artefacto sanitario***. Método de Hunter

Edificios de alta ocupación: Teatros, Stadiums, escuelas


Edificios Multifamiliares, con 3 o más Edificios públicos, comerciales, y similares
Deptos. industriales
Unidades Hunter (UH) Unidades Hunter (UH) Unidades Hunter (UH)
Total Fria Caliente Total Fria Caliente Total Fria
3.5 2.6 2.6

0.5 0.4 0.4

2.5 1.9 1.9 4.0 3.0 3.0

1.0 1.0 1.5 1.5

0.5 0.5 0.8 0.8

2.5 2.5 2.5 2.5

1.0 1.0 1.0 1.0

1.0 0.8 0.8 1.5 1.1 1.1

1.0 0.8 0.8 2.0 1.5 1.5

0.5 0.4 0.4 1.0 0.8 0.8 1.0 0.8

3.0 2.3 2.3

2.0 1.5 1.5 2.0 1.5 1.5

5.0 3.8 3.8

4.0 4.0 5.0 5.0

5.0 5.0 6.0 6.0

2.5 2.5 2.5 2.5 4.0 4.0

2.5 2.5 2.5 2.5 3.5 3.5

5.0 5.0 5.0 5.0 8.0 8.0

3.0 3.0 5.5 5.5 7.0 7.0

7.0 7.0 8.0 8.0 10.0 10.0

4.0 3.0 3.0


n: Teatros, Stadiums, escuelas

es Hunter (UH)
Caliente

0.8
Tabla 1.9.Unidades de

Conjuntos de Baño, Inodoros con tanques


de descarga de 6L

Medio Baño o de Visitas


1 Baño completo o conjunto de Baño
1 1/2 Baño
2 Baños completos
2 1/2 Baños
3 Baños completos
1/2 Baño Adicional
Grupo Adicional de 1 Baño completo
Conjuntos de Baño, Inodoros con tanques
de descarga de 12 L

Medio Baño o de Visitas


1 Baño completo
1 1/2 Baño
2 Baños completos
2 1/2 Baño
3 Baños completos
1/2 Baño Adicional
Grupo Adicional de Baño

Otros Conjuntos de Baño

Baño completo,Inodoros con válvula de


descarga de 6L

Baño completo, Inodoro con válvula de


descarga de 12 L

Cocina completa ( Lavaplatos y Maquina de


Lavar platos)
Lavandería completa ( Lavandería y
Maquina de lavar ropa)

**** Fuente: National Standard Plumbing Code 2006


Baño Completo: Comprende un conjunto de 1 Inodoro, 1 o 2 lavamanos (l
Medio Baño: Comprende 1 Inodoro y un lavamanos o lavatorio.
Tabla 1.9.Unidades de gasto para conjuntos de artefactos *** Método de Hunter

Total en viviendas individuales o de dos departamentos Total en edificios multifamiliares mayores o iguales a
Total UH Agua Fría UH Agua Caliente UH Total UH
3.5 3.3 0.8 2.5
5.0 5.0 3.8 3.5
6.0 6.0 4.5
7.0 7.0 7.0
8.0 8.0 8.0
9.0 9.0 9.0
0.5 0.5 0.5
1.0 1.0 1.0

Total UH Agua Fría UH Agua Caliente UH Total UH

4.0 3.8 0.8 3.0


6.0 6.0 3.8 5.0
8.0 8.0 4.5
10.0 10.0 7.0
11.0 11.0 8.0
12.0 12.0 9.0
0.5 0.5 0.5
1.0 1.0 1.0

Total UH Agua Fría UH Agua Caliente UH Total UH

6.0 6.0 3.8 4.0

8.0 8.0 3.8 6.0

2.0 1.1 2.0 1.5

5.0 4.5 4.5 3.0

lumbing Code 2006


onjunto de 1 Inodoro, 1 o 2 lavamanos (lavatorios), 1 Tina c/ducha o 1 Tina más 1 ducha.
ro y un lavamanos o lavatorio.
Hunter

edificios multifamiliares mayores o iguales a 3 Deptos.


Agua Fría UH Agua Caliente UH
2.5 0.4
3.5 3.0

Agua Fría UH Agua Caliente UH

3.0 0.4
5.0 3.0

Agua Fría UH Agua Caliente UH

4.0 3.0

6.0 3.0

0.8 1.5

2.6 2.6
3
Tabla 1.10. Caudales máximos probables. Método de Hunter

U.GASTO TANQUE VALVULA U. GASTO TANQUE VALVULA


1 51 1.02 1.79
2 52 1.03 1.81
3 0.15 53 1.04 1.82
4 0.17 54 1.06 1.84
5 0.19 0.85 55 1.07 1.85
6 0.22 0.87 56 1.08 1.87
7 0.24 0.9 57 1.1 1.88
8 0.26 0.92 58 1.11 1.9
9 0.28 0.95 59 1.12 1.91
10 0.30 0.97 60 1.14 1.93
11 0.32 1 61 1.15 1.94
12 0.34 1.02 62 1.16 1.95
13 0.36 1.04 63 1.17 1.97
14 0.38 1.07 64 1.18 1.98
15 0.4 1.09 65 1.2 1.99
16 0.42 1.11 66 1.21 2.01
17 0.44 1.14 67 1.22 2.02
18 0.46 1.16 68 1.23 2.03
19 0.48 1.18 69 1.24 2.04
20 0.5 1.2 70 1.25 2.06
21 0.52 1.23 71 1.26 2.07
22 0.54 1.25 72 1.27 2.08
23 0.56 1.27 73 1.28 2.09
24 0.58 1.29 74 1.29 2.1
25 0.59 1.31 75 1.3 2.11
26 0.61 1.33 76 1.31 2.12
27 0.63 1.35 77 1.32 2.13
28 0.65 1.37 78 1.33 2.14
29 0.67 1.4 79 1.34 2.15
30 0.68 1.42 80 1.35 2.16
31 0.7 1.44 81 1.36 2.17
32 0.72 1.46 82 1.37 2.18
33 0.74 1.48 83 1.38 2.19
34 0.75 1.49 84 1.39 2.2
35 0.77 1.51 85 1.4 2.21
36 0.79 1.53 86 1.4 2.22
37 0.8 1.55 87 1.41 2.23
38 0.82 1.57 88 1.42 2.24
39 0.84 1.59 89 1.43 2.24
40 0.85 1.61 90 1.44 2.25
41 0.87 1.62 91 1.44 2.26
42 0.88 1.64 92 1.45 2.27
43 0.9 1.66 93 1.46 2.27
44 0.91 1.68 94 1.46 2.28
45 0.93 1.69 95 1.47 2.29
46 0.94 1.71 96 1.48 2.29
47 0.96 1.73 97 1.48 2.3
48 0.97 1.74 98 1.49 2.31
49 0.99 1.76 99 1.5 2.31
50 1 1.78 100 1.54 2.35
NOTA 1.- Los gastos están dados en lt/s, corresponden a un ajuste de la tabla original del Método Hunter

Tabla 1.10 (Continuación). Caudales máximos probables. Método de

U. GASTO TANQUE VALVULA U.GASTO TANQUE VALVULA


610 4.97 5.39 1250 8.17 8.17
620 5.03 5.44 1275 8.27 8.27
630 5.08 5.48 1300 8.37 8.37
640 5.14 5.53 1325 8.47 8.47
650 5.2 5.58 1350 8.56 8.56
660 5.25 5.62 1375 8.66 8.66
670 5.31 5.67 1400 8.76 8.76
680 5.37 5.72 1425 8.86 8.86
690 5.42 5.76 1450 8.96 8.96
700 5.48 5.81 1475 9.06 9.06
710 5.54 5.86 1500 9.15 9.15
720 5.59 5.9 1525 9.25 9.25
730 5.65 5.95 1550 9.35 9.35
740 5.71 6 1575 9.45 9.45
750 5.76 6.04 1600 9.55 9.55
760 5.82 6.09 1625 9.65 9.65
770 5.88 6.14 1650 9.74 9.74
780 5.93 6.18 1675 9.84 9.84
790 5.99 6.23 1700 9.94 9.94
800 6.05 6.28 1725 10.04 10.04
810 6.11 6.32 1750 10.14 10.14
820 6.16 6.37 1775 10.23 10.23
830 6.22 6.42 1800 10.33 10.33
840 6.28 6.46 1825 10.43 10.43
850 6.33 6.51 1850 10.53 10.53
860 6.39 6.56 1875 10.63 10.63
870 6.45 6.6 1900 10.72 10.72
880 6.5 6.65 1925 10.82 10.82
890 6.56 6.7 1950 10.92 10.92
900 6.62 6.74 1975 11.02 11.02
910 6.67 6.79 2000 11.11 11.11
920 6.73 6.84 2025 11.21 11.21
930 6.79 6.88 2050 11.31 11.31
940 6.84 6.93 2075 11.41 11.41
950 6.9 6.96 2100 11.5 11.5
960 6.96 7.02 2125 11.6 11.6
970 7.01 7.07 2150 11.7 11.7
980 7.07 7.12 2175 11.8 11.8
990 7.13 7.16 2200 11.89 11.89
1000 7.18 7.21 2225 11.99 11.99
1025 7.22 7.28 2250 12.09 12.09
1050 7.28 7.38 2275 12.19 12.19
1075 7.38 7.48 2300 12.28 12.28
1100 7.48 7.58 2325 12.38 12.38
1125 7.68 7.68 2350 12.48 12.48
1150 7.77 7.77 2375 12.58 12.58
1175 7.87 7.87 2400 12.67 12.67
1200 7.97 7.97 2425 12.77 12.77
1225 9.07 8.07 2450 12.87 12.87
NOTA 1.- Los gastos están dados en lt/s, corresponden a un ajuste de la tabla original del Método de Hunter
bles. Método de Hunter

U. GASTO TANQUE VALVULA


110 1.61 2.43
120 1.68 2.5
130 1.75 2.58
140 1.82 2.66
150 1.89 2.73
160 1.96 2.8
170 2.03 2.88
180 2.1 2.95
190 2.17 3.02
200 2.24 3.09
210 2.31 3.16
220 2.39 3.23
230 2.46 3.3
240 2.53 3.37
250 2.6 3.43
260 2.67 3.5
270 2.73 3.56
280 2.8 3.63
290 2.87 3.69
300 2.94 3.75
310 3.01 3.81
320 3.08 3.88
330 3.15 3.93
340 3.22 3.99
350 3.29 4.05
360 3.36 4.11
370 3.43 4.17
380 3.49 4.22
390 3.56 4.28
400 3.63 4.33
410 3.7 4.38
420 3.77 4.44
430 3.83 4.49
440 3.9 4.54
450 3.97 4.59
460 4.04 4.64
470 4.11 4.69
480 4.17 4.74
490 4.24 4.78
500 4.31 4.88
510 4.4 4.92
520 4.46 4.97
530 4.51 5.02
540 4.57 5.06
550 4.63 5.11
560 4.68 5.16
570 4.74 5.2
580 4.8 5.25
590 4.85 5.3
600 4.91 5.34
nal del Método Hunter

áximos probables. Método de Hunter

U. GASTO TANQUE VALVULA


2475 12.96 12.96
2500 13.06 13.06
2525 13.16 13.16
2550 13.25 13.25
2575 13.35 13.35
2600 13.45 13.45
2625 13.55 13.55
2650 13.64 13.64
2675 13.74 13.74
2700 13.84 13.84
2725 13.93 13.93
2750 14.03 14.03
2775 14.13 14.13
2800 14.22 14.22
2825 14.32 14.32
2850 14.42 14.42
2875 14.51 14.51
2900 14.61 14.61
2925 14.71 14.71
2950 14.8 14.8
2975 14.9 14.9
3000 14.99 14.99
3050 15.19 15.19
3100 15.38 15.38
3150 15.57 15.57
3200 15.76 15.76
3250 15.96 15.96
3300 16.15 16.15
3350 16.34 16.34
3400 16.53 16.53
3450 16.72 16.72
3500 16.91 16.91
3550 17.11 17.11
3600 17.3 17.3
3650 17.49 17.49
3700 17.68 17.68
3750 17.87 17.87
3800 18.06 18.06
3850 18.25 18.25
3900 18.44 18.44
3950 18.63 18.63
4000 18.82 18.82

Criterio Definido por Comisión


Fórmulas y valores desarrollados por el
Ing. Alfonso Pomarino C.
Procesado por Ing. Sergio Rodriguez

nal del Método de Hunter


Tabla1.8. Caudales máximos probables (L/s)***

Unidades Caudal L/s Unidades Caudal L/s


Hunter Hunter

I. c/ Válvula
UH I. c/Tanque de de Descarga UH I. c/Tanque
Gravedad de Gravedad
3 3 0.19 120 3.06
4 4 0.25 140 3.31
4.5 22 5 0.28 1.38 160 3.56
5 23 6 0.31 1.44 180 3.81
6 24 7 0.38 1.50 200 4.06
7 25 8 0.44 1.56 225 4.38
7.5 26 9 0.47 1.63 250 4.69
8 27 10 0.50 1.69 300 5.31
8.5 28 11 0.53 1.75 400 6.56
9 29 12 0.56 1.81 500 7.81
10 29.5 13 0.63 1.84 750 10.63
10.5 30 14 0.66 1.88 1,000 13.13
11 31 15 0.69 1.94 1,250 15.00
12 32 16 0.75 2.00 1,500 16.88
12.5 33 17 0.78 2.06 1,750 18.75
13 33.5 18 0.81 2.09 2,000 20.31
13.5 34 19 0.84 2.13 2,500 23.75
14 35 20 0.88 2.19 3,000 27.19
17 38 25 1.06 2.38 4,000 32.81
20 41 30 1.25 2.56 5,000 37.50
25 47 40 1.56 2.94 6,000 40.63
29 51 50 1.81 3.19 7,000 43.75
33 55 60 2.06 3.44 8,000 45.63
39 62 80 2.44 3.88 9,000 47.50
44 68 100 2.75 4.25 10,000 49.38

*** Fuente: National Standard Plumbing Code,2006


)***

Caudal L/s

I. c/ Válvula
de Descarga

4.63 49 74
4.88 53 78
5.19 57 83
5.44 61 87
5.69 65 91
5.94 70 95
6.25 75 100
6.88 85 110
7.81 105 125
8.75 125 140
10.94 170 175
13.13 210 210
15.00 240 240
16.88 270 270
18.75 300 300
20.31 325 325
23.75 380 380
27.19 435 435
32.81 525 525
37.50 600 600
40.63 650 650
43.75 700 700
45.63 730 730
47.50 760 760
49.38 790 790
Tabla 1.5. Velocidades máximas admisibles en

Diámetro nominal DN

mm
15
20
25
40
50
60
75
100
cidades máximas admisibles en tuberías de agua potable

Velocidad máxima Caudal máximo

m/s L/s
1,6 0,2
2,0 0,6
2,3 1,2
2,5 4,0
2,5 5,7
2,5 8,9
2,5 12,0
2,5 18,0
Ecuación de Hazen Williams

Q= m3/s
C (PVC) = 140
C (FG )= 125
D= m
Pérdidas de carga en contadores usuales ( en m de columna de agua)

Diámetros Gasto en L/s


DN ( mm)
0.3 0.6 1 1.5 2 2.5 3 3.5 4 5 6 7 8 10
15 2 5 16 32
20 1 3 8 18 32
25 1 4 9 16 24
30 1 3 6 9 16 25 32
40 1 2 4 6 9 10 14 22 30
50 1 2 3 4 5 8 11 15 20 31
60 1 2 2 3 4 6 8 11 17
80 1 2 3 4 5 8
100 1 2 2 3
e agua)

12 15 20 25 30

25
13 18 30
5 7 11 17 25
Unidades de presión

Libras/inch²
Unidades de Atmósfera Bar (psi) kg/cm²
presión (psi)
Atmósfera 1 0.987 0.068 0.968
Bar 1.03 1 0.981
Libras/inch²
(psi)
(psi) 14.7 14.5 1 14.22
kg/cm² 1.033 1.02 0.07031 1
kg/m² 10332 10197 703.100 10000
Kilopascal 101.3 100 6.895 98.07
N/m²(Pa) 6895
mH₂O 10.34 10.207 0.703 0.10
presión

kg/m² Kilopascal mH₂O N/m²

0.01
0.01

0.001 0.145
0.0001 0.01 10.01
1 101.97 0.001 0.102
0.01 1 0.102 0.001
0.102 0.001 0.000102 1
0.001 101.97 1 0.102
Tabla 1.6. Unidades de gasto por artefacto s

Viviendas Unifamiliares o de dos


Artefacto Sanitario Deptos.
Unidades Hunter (UH)
Total Fria Caliente
Tina de Baño o Tina con Ducha 4.0 3.0 3.0

Bidet 1.0 0.8 0.8

Lavadora Automática (doméstica) 4.0 3.0 3.0

Máquina de lavar platos Automático (doméstico) 1.5 1.5

Bebedero

Grifo de Riego 2.5 2.5

Grifo de Riego Adicional, por c/ Unid. añadida 1.0 1.0

Lavaplatos o pileta de cocina 1.5 1.1 1.1

Lapaplatos o pileta de cocina de uso exclusivo** 3.0 2.0 2.0

Lavandería o pileta de lavado 2.0 1.5 1.5

Lavamanos o Lavatorio 1.0 0.8 0.8

Pileta de Servicio

Ducha individual 2.0 1.5 1.5

Ducha de uso contínuo

Urinario c/Válvula de descarga de 3.75 L

Urinario, c/Válvula de descarga > a 3.75 L

Inodoro c/tanque de descarga de 6 L 2.5 2.5

Inodoro c/ tanque de hidropresión de 6 L 2.5 2.5

Inodoro, c/válvula de descarga de 6 L 5.0 5.0

Inodoro, c/ tanque de descarga de 13 L. 3.0 3.0

Inodoro, c/válvula de descarga de 13 L 7.0 7.0

Tina de Hidromasaje 4.0 3.0 3.0

**** Fuente: National Standard Plumbing Code 2006


** Uso de lavaplatos sin contar con con máquina de
lavar platos
Unidades de gasto por artefacto sanitario***. Método de Hunter

Edificios de alta ocupación: Teatros, Stadiums, escuelas


Edificios Multifamiliares, con 3 o más y similares
Deptos. Edificios públicos, comerciales.
Unidades Hunter (UH) Unidades Hunter (UH) Unidades Hunter (UH)
Total Fria Caliente Total Fria Caliente Total Fria
3.5 2.6 2.6

0.5 0.4 0.4

2.5 1.9 1.9 4.0 3.0 3.0

1.0 1.0 1.5 1.5

0.5 0.5 0.8 0.8

2.5 2.5 2.5 2.5

1.0 1.0 1.0 1.0

1.0 0.8 0.8 1.5 1.1 1.1

3.0 2.0 2.0 4.0 3.0 3.0

1.0 0.8 0.8 2.0 1.5 1.5

0.5 0.4 0.4 1.0 0.8 0.8 1.0 0.8

3.0 2.3 2.3

2.0 1.5 1.5 2.0 1.5 1.5

5.0 3.8 3.8 5.0 3.8

4.0 4.0 5.0 5.0

5.0 5.0 6.0 6.0

2.5 2.5 2.5 2.5 4.0 4.0

2.5 2.5 2.5 2.5 3.5 3.5

5.0 5.0 5.0 5.0 8.0 8.0

3.0 3.0 5.5 5.5 7.0 7.0

7.0 7.0 8.0 8.0 10.0 10.0

4.0 3.0 3.0


n: Teatros, Stadiums, escuelas

es Hunter (UH)
Caliente

0.8

3.8
Gastos probables con tanque (L/S)
0.00 < UG <100 QMP (L/S) =0.083373 + 0.022533 x UG - 8.31E-5xUG²
100 ≤ UG ≤ 500 QMP (L/S) = 0.814228 + 0.007263x UG - 5.55E-7xUG²
500 < UG ≤ 1000 QMP (L/S) = 1.501666 + 0.005683xUG

3.43
0.40

Tabla 1.10. Caudales máximos probables. Método de Hunter

U.GASTO TANQUE VALVULA U. GASTO TANQUE VALVULA


1 51 1.02 1.79
2 52 1.03 1.81
3 0.15 53 1.04 1.82
4 0.17 54 1.06 1.84
5 0.19 0.85 55 1.07 1.85
6 0.22 0.87 56 1.08 1.87
7 0.24 0.9 57 1.1 1.88
8 0.26 0.92 58 1.11 1.9
9 0.28 0.95 59 1.12 1.91
10 0.3 0.97 60 1.14 1.93
11 0.32 1 61 1.15 1.94
12 0.34 1.02 62 1.16 1.95
13 0.36 1.04 63 1.17 1.97
14 0.38 1.07 64 1.18 1.98
15 0.4 1.09 65 1.2 1.99
16 0.42 1.11 66 1.21 2.01
17 0.44 1.14 67 1.22 2.02
18 0.46 1.16 68 1.23 2.03
19 0.48 1.18 69 1.24 2.04
20 0.5 1.2 70 1.25 2.06
21 0.52 1.23 71 1.26 2.07
22 0.54 1.25 72 1.27 2.08
23 0.56 1.27 73 1.28 2.09
24 0.58 1.29 74 1.29 2.1
25 0.59 1.31 75 1.3 2.11
26 0.61 1.33 76 1.31 2.12
27 0.63 1.35 77 1.32 2.13
28 0.65 1.37 78 1.33 2.14
29 0.67 1.4 79 1.34 2.15
30 0.68 1.42 80 1.35 2.16
31 0.7 1.44 81 1.36 2.17
32 0.72 1.46 82 1.37 2.18
33 0.74 1.48 83 1.38 2.19
34 0.75 1.49 84 1.39 2.2
35 0.77 1.51 85 1.4 2.21
36 0.79 1.53 86 1.4 2.22
37 0.8 1.55 87 1.41 2.23
38 0.82 1.57 88 1.42 2.24
39 0.84 1.59 89 1.43 2.24
40 0.85 1.61 90 1.44 2.25
41 0.87 1.62 91 1.44 2.26
42 0.88 1.64 92 1.45 2.27
43 0.9 1.66 93 1.46 2.27
44 0.91 1.68 94 1.46 2.28
45 0.93 1.69 95 1.47 2.29
46 0.94 1.71 96 1.48 2.29
47 0.96 1.73 97 1.48 2.3
48 0.97 1.74 98 1.49 2.31
49 0.99 1.76 99 1.5 2.31
50 1 1.78 100 1.54 2.35
NOTA 1.- Los gastos están dados en lt/s, corresponden a un ajuste de la tabla original del Método Hunter

Tabla 1.10 (Continuación). Caudales máximos probables. Método de

U. GASTO TANQUE VALVULA U.GASTO TANQUE VALVULA


610 4.97 5.39 1250 8.17 8.17
620 5.03 5.44 1275 8.27 8.27
630 5.08 5.48 1300 8.37 8.37
640 5.14 5.53 1325 8.47 8.47
650 5.2 5.58 1350 8.56 8.56
660 5.25 5.62 1375 8.66 8.66
670 5.31 5.67 1400 8.76 8.76
680 5.37 5.72 1425 8.86 8.86
690 5.42 5.76 1450 8.96 8.96
700 5.48 5.81 1475 9.06 9.06
710 5.54 5.86 1500 9.15 9.15
720 5.59 5.9 1525 9.25 9.25
730 5.65 5.95 1550 9.35 9.35
740 5.71 6 1575 9.45 9.45
750 5.76 6.04 1600 9.55 9.55
760 5.82 6.09 1625 9.65 9.65
770 5.88 6.14 1650 9.74 9.74
780 5.93 6.18 1675 9.84 9.84
790 5.99 6.23 1700 9.94 9.94
800 6.05 6.28 1725 10.04 10.04
810 6.11 6.32 1750 10.14 10.14
820 6.16 6.37 1775 10.23 10.23
830 6.22 6.42 1800 10.33 10.33
840 6.28 6.46 1825 10.43 10.43
850 6.33 6.51 1850 10.53 10.53
860 6.39 6.56 1875 10.63 10.63
870 6.45 6.6 1900 10.72 10.72
880 6.5 6.65 1925 10.82 10.82
890 6.56 6.7 1950 10.92 10.92
900 6.62 6.74 1975 11.02 11.02
910 6.67 6.79 2000 11.11 11.11
920 6.73 6.84 2025 11.21 11.21
930 6.79 6.88 2050 11.31 11.31
940 6.84 6.93 2075 11.41 11.41
950 6.9 6.96 2100 11.5 11.5
960 6.96 7.02 2125 11.6 11.6
970 7.01 7.07 2150 11.7 11.7
980 7.07 7.12 2175 11.8 11.8
990 7.13 7.16 2200 11.89 11.89
1000 7.18 7.21 2225 11.99 11.99
1025 7.22 7.28 2250 12.09 12.09
1050 7.28 7.38 2275 12.19 12.19
1075 7.38 7.48 2300 12.28 12.28
1100 7.48 7.58 2325 12.38 12.38
1125 7.68 7.68 2350 12.48 12.48
1150 7.77 7.77 2375 12.58 12.58
1175 7.87 7.87 2400 12.67 12.67
1200 7.97 7.97 2425 12.77 12.77
1225 9.07 8.07 2450 12.87 12.87
NOTA 1.- Los gastos están dados en lt/s, corresponden a un ajuste de la tabla original del Método de Hunter
bles. Método de Hunter

U. GASTO TANQUE VALVULA


110 1.61 2.43
120 1.68 2.5
130 1.75 2.58
140 1.82 2.66
150 1.89 2.73
160 1.96 2.8
170 2.03 2.88
180 2.1 2.95
190 2.17 3.02
200 2.24 3.09
210 2.31 3.16
220 2.39 3.23
230 2.46 3.3
240 2.53 3.37
250 2.6 3.43
260 2.67 3.5
270 2.73 3.56
280 2.8 3.63
290 2.87 3.69
300 2.94 3.75
310 3.01 3.81
320 3.08 3.88
330 3.15 3.93
340 3.22 3.99
350 3.29 4.05
360 3.36 4.11
370 3.43 4.17
380 3.49 4.22
390 3.56 4.28
400 3.63 4.33
410 3.7 4.38
420 3.77 4.44
430 3.83 4.49
440 3.9 4.54
450 3.97 4.59
460 4.04 4.64
470 4.11 4.69
480 4.17 4.74
490 4.24 4.78
500 4.31 4.88
510 4.4 4.92
520 4.46 4.97
530 4.51 5.02
540 4.57 5.06
550 4.63 5.11
560 4.68 5.16
570 4.74 5.2
580 4.8 5.25
590 4.85 5.3
600 4.91 5.34
nal del Método Hunter

áximos probables. Método de Hunter

U. GASTO TANQUE VALVULA


2475 12.96 12.96
2500 13.06 13.06
2525 13.16 13.16
2550 13.25 13.25
2575 13.35 13.35
2600 13.45 13.45
2625 13.55 13.55
2650 13.64 13.64
2675 13.74 13.74
2700 13.84 13.84
2725 13.93 13.93
2750 14.03 14.03
2775 14.13 14.13
2800 14.22 14.22
2825 14.32 14.32
2850 14.42 14.42
2875 14.51 14.51
2900 14.61 14.61
2925 14.71 14.71
2950 14.8 14.8
2975 14.9 14.9
3000 14.99 14.99
3050 15.19 15.19
3100 15.38 15.38
3150 15.57 15.57
3200 15.76 15.76
3250 15.96 15.96
3300 16.15 16.15
3350 16.34 16.34
3400 16.53 16.53
3450 16.72 16.72
3500 16.91 16.91
3550 17.11 17.11
3600 17.3 17.3
3650 17.49 17.49
3700 17.68 17.68
3750 17.87 17.87
3800 18.06 18.06
3850 18.25 18.25
3900 18.44 18.44
3950 18.63 18.63
4000 18.82 18.82

Criterio Definido por Comisión


Fórmulas y valores desarrollados por el
Ing. Alfonso Pomarino C.
Procesado por Ing. Sergio Rodriguez

nal del Método de Hunter