You are on page 1of 1

Notes: -

1. ALL DIMENSIONS ARE IN FEET AND


LEVELS ARE IN METERS
2. THIS DRAWING SHALL BE READ IN
CONJUNCTION WITH OTHER RELEVANT
DRAWINGS.
3. ALL REINFORCEMENT SHALL CONFIRM
TO IS-1786 WITH TENSILE STRENGTH OF
(Fy = 500MPa)
4. THE CLEAR COVER TO THE
0.50L REINFORCEMENT SHALL BE 40mm
L 0.30L INCASE OF FOUNDATIONS, 20mm IN
CASE OF BEAMS AND COLUMNS AND
12mm IN CASE OF SLABS AND SHEAR
3# 16 dia bars (T) 3# 16 dia bars (T) WALLS OR AS PER IS 456-2000.
5. CONTROLLED GRADE OF CONCRETE
HAVING 28DAYS CHARACTERISTIC
STRENGTH OF 20MPa AND SHALL
CONFIRM TO IS 456-2000
2# 20 dia bars (ext) 6. ALL LAPS AND DEVELOPMENT LENGTH
SHALL CONFIRM TO IS456-2000.
2L 10 dia rings at 6'' c/c 2L 10 dia rings at 6'' c/c 7. THE DEPTH OF FOOTING IS TAKEN AS
2.50 m HAVING ASSUMED SAFE BEARING
2# 16 dia bars (ext) CAPACITY OF 6ton/sqm.
8. DISCREPANCY IF ANY SHOULD BE
3# 20 dia bars (B) 3# 20 dia bars (B) BROUGHT TO THE NOTICE OF
ARCHITECT/STRUCTURAL DESIGNER.
SECTION AT CENTER SECTION AT SUPPORT

DETAILS OF FB-2

2# 16 + 1# 20 dia bars (T) 2# 16 + 1# 20 dia bars (T)

2# 20 dia bars (ext)


2L 10 dia rings at 6'' c/c 2L 10 dia rings at 6'' c/c
2# 20 dia bars (ext)
4# 20 dia bars (B) 4# 20 dia bars (B)
SECTION AT CENTER SECTION AT SUPPORT
DETAILS OF FB-1
FLOOR BEAM DETAILS
DSGN WASEEM DRAWING ISSUES FOR
INNOVATIVE CONSULTING ENGINEERS EXECUTING AGENCY

................................

ICE
30-03-2019 R-0 WORKING DRAWINGS
TCD
CKD
RAYEES
RAYEES CONSTUCTION ENGINEERING CONSULTANTS PROJECT: -

SCALE 1: ............. Grand Qadir Plaza, Munawar abad Link Road, Opp Azad Filling Station, Srinagar. J&K CONSTRUCTION OF COMMERCIAL COMPLEX
DATE REVISION DESCRIPTION CHECKED
DRG NO: - E:\ICE\CONSULTANCY\MAHARAJ GUNJ-04 Phone: - 01942480226 Mobile +91 95965 32211 Mail: - Innovativecons1@gmail.com AT MAHARAJ GUNJ, SRINAGAR