You are on page 1of 1

Switch nozzle position as per

latest dwg.
(mirrored), see below capture

switch pos.

So that we need Normalized SA-516-70 coz it has Anti-


corrosion (corrosion resitance) property for SSC
(Sulfide Stress Corrosion cracking). However, some
properties (e.g., strength and ductility) will be reduced
because of the grain growth, but we can deal with it.

LETHAL

CATEGORY B

switch pos.
1350mm

missing line

REQUIREMENT

Thickness reinforcement
pad ??

pls slightly move this so that


'1000' doesn't collide with the line

surface

MORE

gauge Vertical 1%

25mm 9

713mm used SA 2 1/2


Coating System as follow :
1. Primer, High Build High Solid MIO Epoxy (200um DFT)
2. Finish, Aliphatic Acrylic Polyurethane high gloss (80um DFT).
In ASME SecVIII Div1, Finish colour = Pure WHITE (RAL9010) or Munsell N9.5
anything of SA-516 Gr70 over
1-1/2" must be Normalized.

390mm as latest
300mm as latest revision
revision

760mm