SHOW COMMANDS

IVR
show IVR overall IVR configuation
switch Info show IVR vsan top IVR VSAN topology
Cisco MDS 9000 CLI show
show
switchname
version
Gives switch name
Firmware version information
Troubleshooting
show module Shows info on each module
show tech-support details collects full set of logs
Quick Reference show
show
show
sprom backplane 1
sprom backplane 2
clock
sprom backplane information
sprom backplane information
date/time these logs were collected.
show accouting log log showing any user made changes.
show logging log log of anything happening on switch
show tech intern link link history for every port
SAN-OS 3.x show
show
show
hardware
process
process cpu
Detailed information on the hardware
Process list
Shows CPU process list
show topology
show fcdom dom
topology for each vsan
show switches in each VSAN
_____________________________________ show zoneset active show active zoneset & who’s logged in
show process memory Shows memory usage
show hard intern err show detailed internal errors
show license Shows the switch licenses
show license usage Shows the switch licenses usage
Version 3.0
Compiled by: Kevin Beaulieu, Service Readiness EMC Fibre Channel Interfaces
Based upon documentation by Cisco and EMC Set port state and enable / disable gracefully
Sections from Troubleshooting Guide by Bill Bentley Port / Fabric Information Step 1 switch# config t Enters configuration mode.
show interface brief Brief look at every port in the switch.
Step 2 switch(config)# interface fc1/1 Configures the specified
show interface Info on every port
Key Cisco Primus Solution: interface.
show fcns database List of all WWNs logged into Fabric (all
Common MDS 9000 Family Switch Solutions emc100582 Step 3 switch(config-if)# switchport mode F
switches)
show fcns database detail detailed information of all WWNs. operational state to auto, E, F, FL, Fx, TL,or SD port mode.
show fcs database Fabric config status, links attached Step 4 switch(config-if)# No shutdown enables it.
Release Notes, SAN-OS, Upgrade Instructions located on ESN
WWNs with port WWNs shutdown Gracefully shuts down the interface and administratively
Product Page:
show flogi database Links interface, 24 bit address and disables traffic flow (default).
http://www.cs.isus.emc.com/csweb2/esn/esnhome.htm#Connectrix%2
0MDS%209000%20Family attached WWNs (one switch only)
show flogi internal info Detailed info about devices logged in
Cisco Documentation only at Cisco’s Site: such as BB credit etc... Creating User Accounts
http://www.cisco.com/en/US/products/ps5989/tsd_products_support_s
Network Information Step 1 Enter configuration submode with the config terminal
eries_home.html
command.
show interface mgmt0 IP address for supervisor TCP/IP interface
switch# config terminal
show ip route IP information, including FCIP ports
Default logs: show tech-support details (Primus emc70376) Step 2 Create the CLI user with the syntax username <username>
show arp arp table
password <password> role <role>.
show snmp SNMP traffic info & Fabric Manager account info
switch(config)# username user1 password sox2004ch@mps role
network-admin
Events / Errors / Environment At this point, the user “user1” can access the switch with the password
show environment Shows environmental status sox2004ch@mps. Access can be
show module diag Shows diag status for each module console, ssh, telnet or snmp.
show system reset-reason Show supervisor resets, when and why
show process log Look here for switch crashes and core dumps
show processes log details Shows stack trace information Using the CLI to Install a License:
Configuration
show running-config running config information Step 1 Copy the license file to the boot flash of the supervisor:
show startup-config startup config information switch# copy scp://user1@172.22.36.10/tmp/FM_Server.lic
show port-channel database Shows port channel database bootflash:FM_Server.lic
show fcdomain domain-list Shows domains for all domains in fabric Step 2 Verify the license file with the show license file command.
show fcs ie ISL config information switch# show license file FM_Server.lic
show fctimer FC timer variables such as ED_TOV and RA_TOV Step 3 Cross reference the switch’s host-id (VDH=FOX0713037X)
with the one listed in the license file:
VSAN ca-9506# show license host-id
License hostid: VDH=FOX0713037X
show vsan Shows config and status of each VSAN
Step 4 Install the license file:
show vsan membership Shows the interface ports of each VSAN
switch# install license bootflash:FM_Server.lic
show fspf Shows fsfp for each VSAN
Installing license ..done
show fspf database Shows fsfp database for each VSAN
Step 5 Verify that the license has been installed with the show
Zoning license command.
MDS 9513 MDS 9Q20 show zoneset defined zones and zonesets for each VSAN
show zone status zone status information for each VSAN
show zoneset active shows the active zoning for VSANs.
ip Configure IP features
Zoning via CLI IVR Configuration iscsi Enable/Disable iSCSI
ivr Config commands for IVR
logging Modify message logging facilities
Step 1 Determine whether to use IVR NAT (Network Address Translation).
no Negate a command or set its defaults
Step 2 If you do not plan to use IVR NAT (supported as of Cisco MDS SAN-
ntp NTP Configuration
OS Release 2.1(1a)), verify that unique domain IDs are configured in all
power Configure power supply
switches and VSANs participating in IVR.
poweroff Poweroff a module in the switch
Step 3 Enable IVR in the border switches.
radius Configure RADIUS configuration distribution
Step 4 Configure fabric distribution as required.
radius-server Configure RADIUS related parameters
Step 1 Create the zone, building a zone name that reflects the names Step 5 Configure the IVR topology, either manually or automatically.
role Configure roles
of the members. Step 6 Create and activate Inter VSAN Zone Sets in all of the IVR-enabled
ca-9506# config terminal rscn Config commands for RSCN
border switches, either manually or using fabric distribution.
scheduler Config commands for scheduler
Enter configuration commands, one per line. End with CNTL/Z. Step 7 Verify the IVR configuration.
snmp-server Configure snmp server
ca-9506(config)# zone name Z_host1_fcaw0_symm78FA03ab vsan
804
IVR detailed steps ssh Configure SSH parameters
ssm Config commands for SSM
ca-9506(config-zone)# member pwwn 22:35:00:0c:85:e9:d2:c2
Step 3 switch# config t Enters configuration mode. switchname Configure system's network name
ca-9506(config-zone)# member pwwn 10:00:00:00:c9:32:8b:a8
switch(config)# ivr enable Enables IVR. system System config command
Step 2 Then add the zone to the zoneset tacacs+ Enable tacacs+
ca-9506(config)# zoneset name ZS_Engr_primary vsan 804 Step 4 switch# config t Enters configuration mode. telnet Enable telnet
ca-9506(config-zoneset)# member Z_host1_fcaw0_symm78FA03ab username Configure user information.
switch(config)# ivr distribute Enables IVR distribution.
Step 3 Display the zoneset: Vsan Enter the vsan configuration mode
ca-9506# show zoneset name ZS_Engr_primary vsan 804 wwn Set secondary base MAC addr and range
zoneset name ZS_Engr_primary vsan 804 Step 5 switch# config t Enters configuration mode.
switch(config)# ivr vsan-topology database zone Zone configuration commands
zone name Z_host1_fcaw0_symm78FA03ab vsan 804 zone-attribute-group Zone attribute group commands
pwwn 22:35:00:0c:85:e9:d2:c2 Enters the VSAN topology database configuration mode for IVR feature.
switch(config-ivr-topology-db)# autonomous-fabric-id zoneset Zoneset configuration commands
pwwn 10:00:00:00:c9:32:8b:a8
1 switch 20:00:00:05:30:01:1b:b8 vsan-ranges 1-2,6
Step 4 Finally, to put the zoneset into production activate the zoneset
using zoneset activate name Configures VSANs 1, 2, and 6 to participate in IVR for this switch. Exec commands:
switch(config-ivr-topology-db)# autonomous-fabric-id attach Connect to a specific linecard
ZS_Engr_primary vsan 804. This will activate all the zones in the cd Change current directory
1 switch 20:00:00:05:30:01:1b:c2 vsan-ranges 1-3
zoneset, not just the one that was just added. clear Reset functions
Configures VSANs 1, 2 and 3 to participate in IVR for this switch.
clock Manage the system clock
switch(config)# ivr vsan-topology activate Activates config Enter configuration mode
VSAN Creation the configured IVR topology. copy
delete
Copy from one file to another
Delete a file
switch(config-ivr-topology-db)# end Reverts to EXEC
The steps to create and name a VSAN on a single switch. dir List files in a directory
VSAN 200 is created with the name TapeVSAN and fibre discover Discover information
Step 6 switch# config t Enters configuration mode. exit Exit from the EXEC
channel interface fc 1/1 is added. switch(config)# ivr zone name sample_vsan2-3 fcping Ping an N-Port
Creates an IVR zone named sample_vsan2-3. fctrace Trace the route for an N-Port.
switch1# conf t switch(config-ivr-zone)# member pwwn find Find a file below current directory
Enter configuration commands, one per line. End with 21:00:00:e0:8b:02:ca:4a vsan 3 install Upgrade software
CNTL/Z. Follow regular zoning steps. ips Various sibyte module commands
ivr IVR exec commands
switch(config)# vsan database mkdir Create new directory
switch(config-vsan-db)# vsan 200 name TapeVSAN Step 7 use show ivr and show ivr zoneset commands
to check the configuration. move Move files
switch(config-vsan-db)# vsan 200 interface fc 1/1 no Disable debugging functions
switch(config-vsan-db)# ^Z ping Send echo messages
Configure commands: port-channel
pwd
Port-Channel related commands
View current directory
aaa Configure aaa functions
reload Reboot the entire box
Configuring Trunking E ports banner Configure banner message rmdir Delete a directory
How to configure the allowed VSAN traffic through the interface fc 1/1. boot Configure boot variables setup Run the basic SETUP command facility
The “all” keyword allows all VSAN traffic to go through the port. clock Configure time-of-day clock show Show running system information
switch# conf t device-alias Device-alias configuration commands sleep Sleep for specified number of seconds
Enter configuration commands, one per line. End with do EXEC command tac-pac Save tac information to location
CNTL/Z. dpvm Configure Dynamic Port Vsan Membership tail Display the last part of a file
telnet Telnet to another system
switch(config)# interface fc 1/1 end Exit from configure mode terminal Set terminal line parameters
switch(config-if)# switchport trunk allowed vsan all exit Exit from configure mode test Test command
<− all VSAN traffic fcalias Fcalias configuration commands traceroute Trace route to destination
switch(config-if)# switchport trunk allowed vsan add fcdomain Enter the fcdomain configuration mode undebug Disable Debugging functions
2 <− only VSAN 2 traffic fcinterop Interop commands update Update license
switch(config-if)# switchport trunk allowed vsan add fcip Enable/Disable FCIP write Write current configuration
2-4 <− VSAN 2 to 4 traffic fcns Name server configuration zone Execute Zone Server commands
zoneset Execute zoneset commands
switch(config-if)# ^Z interface Select an interface to configure