SPECTROSCOPY
PRODUCT BROCHURE

Analytical
Instruments
for
Science
AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 4

Contents
PAGE NO.

Introduction 5

Detection Limits 7

AA500 Atomic Absorption Spectrometer 8

AAWin3 Software – NOW GLP Compliant 12

AA990F Atomic Absorption Spectrometer 18

AAWin2 Software 20

Atomic Absorption Spectrometer Qualification Kit 24

Atomic Fluorescence Spectroscopy 26

AF402 Simultaneous Atomic Fluorescence Spectrometer 28

PFWin Software 31

FP902 Flame Photometer 34

Consumables 38

Analytical
Instruments
for
Science

3
AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 5

4
AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 6

Atomic Absorption Spectroscopy


Since its development in the 1950’s the Atomic Absorption Spectrometer
(AAS) has evolved into an accurate and reliable analytical tool used
extensively in today’s modern laboratory.
AAS is an analytical procedure for the Qualitative and in the form of an aerosol which is converted to an
Quantitative determination of chemical elements in a atomic vapour, atoms present in the vapour are then
sample. The technique is based on the Lambert-beer raised from their ground state to their excited state. The
principle which states that the absorbance of a solution atoms absorb light of a specific wavelength when
(A) is directly proportional to its path length (I) and its moving to an excited energy state, this causes the
concentration (C) when the wavelength of incidence quantity of light absorbed to increase. The light
light remains fixed. This is summarized in the following absorption then can be measured and used for a
equation, where (ε) is the molar absorbtivity. Quantitative determination of the amount of analyte in
a sample.
A= εIc
Atomic Emission Analysis
PG Instruments offer a range of instrumentation For the determination of certain elements, usually those
designed to meet the requirements of all industry excited at high wavelengths, a variation of the standard
sectors including Agricultural, Clinical, Environmental, flame technique can be performed which is called
Food, Metal, Mining and Materials, Petrochemical atomic emission. As the technique relies on the spectral
and Pharmaceutical. Further information about the emission from the flame there is no requirement for the
technique and products can be found in this brochure. hollow cathode lamp. The sample is aspirated into the
flame which causes the ground state atoms to convert
AAS Principle to an excited state. As the excited state is very unstable
Atomic Absorption Spectrophotometers (AAS) have the atoms return to their ground state and emit an
become an industry standard for many elemental emission spectrum consisting of a number of emission
determinations within specific industries. There are wavelengths. The intensity of an emission line will
three AAS techniques including Flame, Graphite therefore increase as the number of excited atoms of
Furnace, and Hydride Generation, all of which have the specific element increases. The specific wavelength
their own advantages and disadvantages due to of the emission can be used for a Quantitative
analytical limitations. The flame technique, being the analysis to determine the concentration of a element in
most common, will determine trace levels (usually ppm) a solution.
for most analytical elements and it is also the most cost
effective technique. If determinations of lower levels Instrumentation
are required (usually ppb) the graphite technique can The Atomic Absorption Spectrometer is made up of five
be used. There are a number of elements that form essential components. Each component is designed to
volatile hydrides and these can be analysed using the produce minimum disruption to the overall system and
hydride technique. many design features are installed to keep the signal to
noise ratio as low as possible.
Atomic Absorption Analysis l Light Source

l Burner Assembly
A hollow cathode lamp containing a coated cathode of
the element that is to be analysed is used as a light
l Optics
source. The light source emits a beam of a specific
wavelength through the flame and into the l Detector

monochromator. The sample is aspirated into the flame l Signal Processing

5
AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 7

Elements – Periodic Table


Group
Period 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
1 2
1
H He
3 4 5 6 7 8 9 10
2
Li Be B C N O F Ne
11 12 13 14 15 16 17 18
3
Na Mg Al Si P S Cl Ar
19 20 21 22 23 24 25 25
26 27 28 29 30 31 32 33 34 35 36
4
K Ca Sc Ti V Cr Mn Mn
Fe Co Ni Cu Zn Ga Ge As Se Br Kr
37 38 39 40 41 42 43 43
44 45 46 47 48 49 50 51 52 53 54
5
Rb Sr Y Zr Nb Mo Tc Ru
Tc Rh Pd Ag Cd In Sn Sb Te I Xe
55 56 72 73 74 75 75
76 77 78 79 80 81 82 83 84 85 86
6
Cs Ba Hf Ta W Re Os
Re Ir Pt Au Hg Tl Pb Bi Po At Rn
87 88 104 105 106 107 107
108 109 110 111 112 113 114 115 116 117 118
7
Fr Ra Rf Db Sg Bh Bh
Hs Mt Ds Rg UUb Uut Uuq Uup Uuh Uus Uuo

57 58 59 75
76
60 61 62 63 64 65 66 67 68 69 70 71
Lanthanides
La Ce Pr Nd
Os
Re Pm Sm Eu Gd Tb Dy Ho Er Tm Yb Lu
89 90 91 107
108
92 93 94 95 96 97 98 99 100 101 102 103
Actinides
Ac Th Pa Bh
Hs
U Np Pu Am Cm Bk Cf Es Fm Md No Lr

Techniques Graphite Analysis


There are three main techniques for AAS analysis each The graphite analysis technique uses an assembly
having their strengths and weaknesses depending on containing a graphite tube to replace the burner. This
the type of analysis required. There are a number of technique is used to analyse very low levels with low
factors to consider when deciding which technique will sample volumes. Although the detection limit is very low,
suit the application. For example: the precision is almost always higher than that of the
l Detection limits l Working range flame technique. The graphite technique requires a

l Speed of analysis l Automation


number of extra components to complete the installation.
l Water Circulating System for Cooling.
l Sample volume l Sample matrix
l Pure Argon Gas.
l Equipment cost l Precision of results
l High Current Power Supply
l Element suitability l Available space required
l Autosampler (optional)
l Clean area l Method development
l Suitable Fume Extraction System
l Running costs

Hydride Analysis
Flame Analysis
The hydride technique requires an additional unit to
Flame AAS is the standard technique used for general
add to the flame AAS system. The Hydride Generator is
purpose analysis. The readings are normally accepted to
used to produce a hydride vapour, for the hydride
be trace levels of ppm and nearly all elements can be
forming elements, by means of a heated tube which fits
analysed to this level. There is a choice of Air/Acetylene
directly to the top of the flame burner. The unit can also
flame used for easily ionised elements and Nitrous
be used for cold vapour technique primarily for Mercury
Oxide/Acetylene flame for the less easily excited
analysis. The hydride technique requires the following
elements. The flame technique requires a number of
extra components to complete the installation.
extra components to complete the installation.
l Pure Argon gas
l Oil free Air Compressor
l Suitable fume extraction system
l Ultra pure Acetylene Gas

l Nitrous Oxide Gas (optional)

l Natural Gas/LPG (optional)

l Autosampler (optional)

l Suitable Fume Extraction System

6
AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 8

Detection limits
Element Wavelength Air/C2H2 N2O/C2H2/C2H2 Air/LPG Graphite Vapour
(nm) mg/l(ppm) mg/l(ppm) mg/l(ppm) µg/l(ppb) µg/l(ppb)
Aluminium (Al) 309.3 n/a 0.028 n/a 0.13 n/a
Antimony (Sb) 217.6 0.092 n/a 0.21 0.29 0.26
Arsenic (As) 193.7 0.12 n/a n/a 0.33 0.05
Barium (Ba) 553.6 n/a 0.031 n/a 0.23 n/a
Beryllium (Be) 234.9 n/a 0.0036 n/a 0.02 n/a
Bismuth (Bi) 223.1 0.0049 n/a 0.03 0.26 0.19
Boron (B) 249.7 n/a 3.5 n/a n/a n/a
Cadmium (Cd) 228.8 0.0028 n/a 0.008 0.01 n/a
Calcium (Ca) 422.7 n/a 0.0037 0.07 0.60 n/a
Chromium (Cr) 357.9 0.0054 n/a 0.6 0.025 n/a
Cobalt (Co) 240.7 0.01 n/a 0.018 2.00 n/a
Copper (Cu) 324.8 0.0045 n/a 0.0026 0.065 n/a
Dysprosium (Dy) 421.7 n/a 0.2 n/a n/a n/a
Europium (Eu) 459.4 n/a 0.04 n/a n/a n/a
Gold (Au) 242.8 0.013 n/a 0.026 3.00 n/a
Indium (In) 303.9 0.07 n/a 0.04 n/a n/a
Iron (Fe) 248.3 0.0043 n/a 0.015 0.06 n/a
Lead (Pb) 217.0 0.013 n/a 0.02 0.03 n/a
Lead (Pb) 283.3 0.016 n/a 0.04 0.08 n/a
Lithium (Li) 670.8 0.0021 n/a 0.004 0.70 n/a
Magnesium (Mn) 285.2 0.0022 n/a 0.002 0.09 n/a
Manganese (Mn) 279.5 0.0016 n/a 0.0019 0.03 n/a
Mercury (Hg) 253.7 n/a n/a n/a 40.0 0.15
Molybdenum(Mo) 313.3 n/a 0.021 n/a 0.14 n/a
Nickel (Ni) 232.0 0.008 n/a 0.012 0.065 n/a
Palladium (Pd) 247.6 0.03 n/a 0.018 0.04 n/a
Phosphorus (P) 213.6 n/a 10.0 n/a n/a n/a
Platinum (Pt) 265.9 0.12 n/a 0.22 0.04 n/a
Potassium (K) 766.5 0.0009 n/a 0.0041 0.40 n/a
Rhodium (Rh) 343.5 0.009 n/a 0.037 0.02 n/a
Rubidium (Rb) 780.0 0.003 n/a 0.005 n/a n/a
Scandium (Sc) 391.2 n/a 0.02 n/a n/a n/a
Selenium (Se) 196.0 0.23 n/a n/a 0.32 0.27
Silicon (Si) 251.6 n/a 0.30 n/a 17.0 n/a
Silver (Ag) 328.1 0.0032 n/a 0.0023 0.04 n/a
Sodium (Na) 589.0 0.0037 n/a 0.0086 n/a n/a
Strontium (Sr) 460.7 n/a 0.005 n/a 0.01 n/a
Tantalum (Ta) 271.5 n/a 2.2 n/a n/a n/a
Tellurium (Te) 214.3 0.054 n/a n/a 3.20 0.43
Thallium (Tl) 276.8 0.014 n/a n/a 0.015 n/a
Tin (Sn) 224.6 n/a 0.21 n/a 15.0 1.39
Titanium (Ti) 365.4 n/a 0.05 n/a 0.5 n/a
Tungsten (W) 255.1 n/a 1.2 n/a n/a n/a
Vanadium (V) 318.5 n/a 0.11 n/a 0.03 n/a
Zinc (Zn) 213.9 0.0033 n/a 0.0037 0.08 n/a

7
AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 9

AA500
AT O M I C A B S O R P T I O N S P E C T R O M E T E R

8
AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 10

U A om nt
N RA ABLion alys
Fu lti

PG IL at an
AV Aut leme

EW D E fo is
m

ll -e
u

E r
The AA500 Atomic Absorption Spectrometer is
a high performance automated instrument
designed to meet the requirements of the
modern laboratory. Due to its versatility and
performance it can be used for a wide range of
applications including:
l Agricultural l Clinical

l Environmental l Food

l Metal l Mining

l Geological l Petrochemical

l Pharmaceutical

The versatile instrument is available in three


configurations:

AA500F – The instrument is equipped with a flame


atomiser only. The positioning of which is fully controlled by
the embedded computer system and AA Win software.
Three flame options are available to the user with the
Air/Acetylene being the standard configuration. This
flame can be used for nearly all standard elements while
the N2O/Acetylene and the Air/LPG (Natural gas) are
available as an option for the more demanding of
elements. All three flame configurations offer coded
burner for full safety protection.

AA500G – The instrument is equipped with a Graphite


Furnace Atomiser only. The graphite head is fixed into the
optical path to maximise performance and eliminate drift.
The temperature of the transversely heated graphite tube
is accurately controlled by means of a precision feedback
system. Pyrolytically coated platform tubes are supplied
as standard to improve the performance and eliminate
many analytical problems associated with this technique.

AA500FG – The instrument is equipped with both Flame


Atomiser and Graphite Atomiser as described above. Both
configurations are installed into the instrument and can
be changed over by a simple selection in the versatile
AA Win software.

NOW GLP COMPLIANT

9
AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 11

AA500 continued
Air/Acetylene
F E AT U R E S & F U N C T I O N S
l The Air/Acetylene flame uses a 100mm single slot
l Embedded PC system built into the instrument as
burner for the standard configuration.
standard on all configurations. Pre-installed AAWin3
l The high sensitivity (Cu 2ppm >0.280abs) is due to
software, user manuals, cook book and Windows
the inert adjustable nebuliser fitted as standard.
operating system.
An acid resistant replacement is available with a
l AAWin3 software provides full control of the
Pt/Ir capillary.
instrument and autosampler with easy method
l The flame can be easily set from blue lean flame
change for each technique. Now GLP compliant.
through stoichiometric to fuel rich by means of
l Automatic 8 Hollow Cathode lamp turret controlled
computer control.
and optimised by the AAWin3 software. Operating
lamp current and warm-up lamp current can be N20/Acetylene
l The N2O/Acetylene flame uses a 50mm single slot
individually controlled to eliminate drift commonly
associated with lamp warming. burner and is available as an optional extra.
l D2 lamp background correction system fitted as
l This flame configuration is used to measure elements
standard to all configurations. High energy D2 lamp less prone to ionization such as: Aluminium, Tin,
and adjustable beam splitter mirror are optimised by Titanium, Calcium, Vanadium and Molybdenum.
the AAWin3 software.
l Switching from Air/Acetylene to N2O/Acetylene to
l Self Reversal background correction system fitted as
Flame Off is fully controlled by the AAWinPro
standard to all configurations. The high performance software.
background system uses the same hollow cathode
lamp as installed for the analysis. Minimum extra Air/Propane (LPG)
l This flame uses a 3 slot burner and with the low
components are required and optical alignment is
very simple. Self Reversal can be used for any element pressure requirement it is also much safer to operate.
at any wavelength making it extremely versatile.
l Due to the low temperature of the flame it is ideal for
l High precision minimal optics ensures maximum light
analysing alkali metals such as: Potassium, Sodium and
throughput to the computer controlled Czerny- Lithium, especially when used in the emission mode.
Turner monochromator.
l Some remote areas of the world have difficulty
l A universal autosampler is available as an optional
obtaining Acetylene gas of a high enough purity to
accessory which is conveniently mounted on the operate the flame correctly, LPG can give a real
front of the AA500 instrument. alternative and offer comparable results for most
l Optional XYZ autosampler provides appropriate elements throughout the wavelength range.
sample volume for multi element analysis, along with
scalable sample capacity for high sample throughput.
l Absorption and Emission modes are standard features
in the AAWin3 software as well as peak height, peak
area, sequential and manual integration modes.

F L A M E AT O M I S E R F E AT U R E S
The flame atomiser offers three flame options:
Air/acetylene is the standard configuration with the
N2O/acetylene and Air/LPG as options.

10
AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 12

Safety Features l Pyrolytically coated graphite tubes are used as standard


l Pressure monitoring for all gases and are manufactured to improve performance as well
l Burner Identification as increase the analytical life.
l Flame sensor l Platform graphite tubes are supplied as standard and
l Drain Trap level Sensor will accept volumes up to 20µl. Non-platform
l Gas Leak Detector graphite tubes are also available as an optional extra.
l Over Pressure in Premix
l Up to 10 heat stages are available for the programming
l Safety Cut off Switch
of the graphite atomiser. These can be set and stored
within the AAWinPro software.
G R A P H I T E AT O M I S E R F E AT U R E S
l The graphite tube is held in position by means of a gas
The integrated Graphite Furnace Atomiser is available piston. Replacement of the graphite tube is performed
in two instrument configurations. by a simple command in the AAWin Software.
l In the AA500G instrument the graphite furnace head
l The graphite tube is efficiently cooled by an additional
is fixed into the light path so alignment with the
water circulation system (supplied separately).
optical path is simple and accurate.
l In the AA500FG instrument the graphite furnace Safety Features
head is fixed behind the flame atomiser assembly and l Argon Gas pressure Sensor
is motorised into position by a simple operation in l Water flow sensor
the AAWinPro software. The positions for the flame l Over Temperature Sensor
and graphite are saved making it easy to swap l Broken graphite tube protection
between modes for different analysis.
l The temperature of the transversely heated graphite
tube is accurately controlled by means of a precision
feedback system and has been designed to reduce
analytical problems normally associated with this
type of technique.

11
AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 13

AAWin3 Software
AAWin3 Software is a powerful and intuitive software product designed to
allow control and data acquisition from the PG Instruments AA500 series
Atomic Absorption Spectrometer.

The AAWin3 software allows the Analyst to control all


aspects of their analytical method whilst providing an
extensive range of tools for data collection, storage
and interpretation.
The software interface consists of three key work-
areas, whilst having toolbars to access many others.
These work areas allow the user to view real-time
signal acquisition, up-to-date display of calibration
curves and a flexible, sample table.
The AAWin3 software offers full automation allowing
the user to measure multiple elements sequentially by
means of a Sample Wizard and optional random access
autosampler.

Lamp turret setup, operating and warm-up currents,


along with the desired analytical wavelength are
easily selected in the configuration.

12
AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 14

N
O
CO
G
W
M
LP
PL
IA
N
Full Automation for Multi-Element Analysis

T
Ensure optimal peak position at the chosen analytical
line by scanning the emissions spectra.
Use the sample table to perform quick measurements
of both Standards and Samples.
Easily append the sample table to add new samples or
even revise calibration curves either by manual
introduction or using an Autosampler.

Each stage of analysis setup is made quick and simple


by means of the Sample Wizard.

View up-to-date calibration curves in 1st, 2nd, or 3rd


order using a standard calibration or standard
addition.
Perform retrospective curve fits to ensure optimum
correlation.

Obtain reliable and accurate results by using the


Energy control feature to manually optimise atomiser View real-time signal acquisition for flame, graphite
position and setup. furnace and hydride generation analysis.
Use the Auto-balance feature to ensure energy level,
and optical alignments are optimised when using
background correction.

For more details and ordering information please visit our website www.pginstruments.com 13
AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 15

Specifications
Spectrometer System
Wavelength range 185nm - 910nm
Light Source Hollow cathode lamp (HCL), Deuterium Arc lamp (D2)
Modulation Square Wave Pulse
Modulation frequency 100hz Self reversal (SR) background, 400hz Deuterium Arc (D2) background

Monochromator
Grating 1800 grooves/mm diffraction grating
Blazed Wavelength 250nm
Focus 300nm
Bandwidth 0.1nm, 0.2nm, 0.4nm, 1.0nm, 2.0nm (Software selectable)
Scan mode Automatic
Photometric Type Single Beam
Wavelength Accuracy +/-0.15nm
Wavelength Resolution 0.2nm +/-0.02nm
Wavelength Reproducibility < 0.05nm
Baseline Stability 0.005Abs/30min
Background Correction Deuterium Arc (D2) 1.0Abs, Self Reversal (SR) 3.0Abs

Flame Analysis
Flame Types Air/Acetylene, Nitrous Oxide/Acetylene, Air/Propane (LPG)
Sensitivity (Cu) 2µg/ml Absorption >0.280Abs
Characteristic Concentration Cu < 0.02µg/ml, Ba < 0.15µg/ml ( N2O/Acetylene)
Detection Limit Cu < 0.004µg/ml
Repeatability Cu < 0.7% (Air/Acetylene Flame)
Ba < 1.0% (Nitrous Oxide/Acetylene Flame)
Burner heads Titanium Alloy
Nebuliser Inert Adjustable Nebuliser, Flow Rate from 2ml - 6ml/min. Pt/Ir capillary
available for high acid concentration
Pre-mix Chamber Corrosion Resistant
Atomiser Selection Automatic changeover (AA500FG), Manual (AA500F)
Safety Features Burner identification, Flame Sensor, Gas Leak Sensor, Low Gas Pressure Sensor,
Drain Trap Sensor, Power Loss Protection

Graphite Furnace Analysis


Graphite Head Transversally Heated
Temperature Range Ambient – 2650C
Heating Program Up to 10 steps. Drying, Ashing, Atomisation, Cleaning
Feedback Voltage and Optical Temperature Control Feedback
Sensitivity (Cu) 50ng/ml Absorption > 0.40Abs
Detection Limit Cd < 0.004ng/ml
Repeatability Cu < 2.0%, Cd < 2.0%
Graphite Tubes Pyrolytically Coated with Platform
Sample Size Up to 20µl
Graphite Cooling Water Circulator Available
Safety Features Argon Pressure Sensor, Water Flow Sensor, Over Temperature Sensor, Broken
Tube Protection

14
AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 16

Specifications
Spectrometer System

Data Processing
PC System Embedded PC, Windows Professional Operating System
Operating Program AA Win Pro software
Analytical Methods Flame AA, Flame AE, Graphite Furnace, Hydride Generation
Readout Mode Continuous, Manual, Peak Height, Peak Area
Calibrations Multi-Standard Calibration, Standard Addition, Interpolation
Data Storage Analytical results, instrument and measurement parameters, signal profile,
calibration curve

Power Requirements
Main Unit 110/230Vac 50/60hz 200W
Graphite Power Supply 220Vac 50/60hz Instantaneous power 5KW Current rating??
Dimensions
Main unit 110cm x 54cm x 54cm 75Kg
Graphite Power Supply 50cm x 54cm x 54cm 70Kg

Standard packaging
AA500F AA500G AA500FG
1 Main unit 1 Main unit 1 Main unit
1 AA500F instruction Manual 1 AA500G instruction Manual 1 AA500F instruction Manual
1 Cook Book 1 Cook book 1 Cook Book
1 Safety Manual 1 Safety Manual 1 Safety Manual
1 System validation document 1 System Validation document 1 System validation document
1 Data coded Air/Acetylene 8 Hollow cathode Lamp 1 Data coded Air/Acetylene
burner Holders burner
1 Inert adjustable Nebuliser 1 Monitor 1 Inert adjustable Nebuliser
8 Hollow cathode Lamp Holders 1 Keyboard and Mouse 8 Hollow cathode Lamp
1 Monitor 1 Low Voltage Power Supply Holders
1 Keyboard and Mouse 2 Power Cables 1 Monitor
1 Low Voltage power Supply 1 Tool Kit 1 Keyboard and Mouse
2 Power Cables 1 Various Gas Fittings 1 Low Voltage power Supply
1 Gas tubing Air 10 Graphite Tubes 2 Power Cables
1 Gas Tubing Acetylene 1 Gas Tubing Argon 1 Gas tubing Air
1 Drain Trap and Tubing 1 Connection Cable (Graphite) 1 Gas Tubing Acetylene
1 Tool Kit 1 Pipette 1 Drain Trap and Tubing
1 Various gas Fittings 1bag Pipette Tips 1 Tool Kit
1 Various gas Fittings
10 Graphite tubes
1 Gas Tubing Argon
1 Connection Cable (graphite)
1 Pipette
1bag Pipette Tips

15
AA SPEC BRO – 060_Layout 1 09/10/2013 12:41 Page 17

Accessories
Autosampler (500-004)
The AS500 Autosampler is an accessory specifically designed for the AA500 Atomic Absorption Spectrometer.
The AS500 can be used to automatically introduce standard and unknown samples to the atomiser for analysis.
It can be used with both flame and graphite furnace instruments.

Flame Analysis
l 38 sample positions (6 for standard samples, 32 for unknown
samples).
l Sample vial size 6ml
l Standard sample vial size 12ml
l Pressure protection for wash
l Position adjustment by AA Win software
l Reproducibility Cu < 0.6% (air/acetylene) Cu< 1.0% (air/LPG)
Ba <1.0% (nitrous oxide/acetylene)
Graphite Analysis
l 76 sample positions (10 for standard samples, 6 for modifier
solutions, 60 for unknown samples)
l Sample vial size 1.5ml
l Modifier vial size 12ml
l Pressure protection for wash
l Up to 3 modifier additions
l Position adjustments by AA-Win Pro software
l Reproducibility Cu <2.0%, Cd <2.0%

Nitrous Oxide/Acetylene Burner (500-023) Inert Adjustable Nebuliser (500-011)


l Titanium alloy l Excellent RSD’s typically
Patent pending
construction <1.0%
l 50mm single slot l Typical read back values

l Coded for safety


better than 2%
l Enhanced sensitivity
l Direct replacement for
l Can be used on all PG
standard burner
Instruments AA500 and
l Designed for higher l Acid resistant nebuliser
AA990 series atomic
temperature flame with Pt/Ir capillary(500-012)
absorption systems
l Adjustable uptake from
l Adjustment of burner l Redesigned spray chamber
2-6ml/min
l Fully adjustable impact
rotation for sensitivity to ensure excellent
optimisation bead drainage properties

Air/Propane (LPG) Burner (500-030) XYZ Autosampler


l Titanium Alloy l High Sample Volume for
construction multi-element analysis
l 3 slot burner l Scalable Sample capacity
l Coded for safety for high sample
l Direct replacement for throughput
standard burner
l Designed for lower
temperature flame
l Adjustment of burner
rotation for sensitivity
optimisation

16 For more details and ordering information please visit our website www.pginstruments.com
AA SPEC BRO – 060_Layout 1 09/10/2013 12:41 Page 18

Hydride Unit (500-007) Water Circulator (GS-005)


l Supplied with For use with AA500G /
temperature controlled AA500FG
heated absorption cell l Re-circulating water
l Cell is easily installed with cooler
l 2Kw cooling capacity
burner attachment
l Can be used for Mercury
l 230v, 270 watts power
cold vapour analysis
(110v available, please
l Sensitivity for most
call for details.)
elements <1ng/ml
l Rust free 5 Litre Water
l Only 2.0ml – 2.5ml per
Capacity
sample required
l 2 Litre per minute
l Universal design l RSD < 3%
flow rate
l Full reaction cycle from l Quick analysis < 30
seconds per measurement l Forced air cooling system
press of start button
l 2x Male quick connection
points 2x Female quick
Air Compressor (GS-003) fittings supplied
l Ultra low noise when l Dimensions (LWH)
running – just 53-59dB (A) 250 x 245 x 700 mm
l 100% Oil Free Design
l Tubing and additional
l Efficient, Horizontal Twin connectors optional
pump unit
l Innovative Compact
Design, perfect for limited Gas Regulators (GS-001, GS-002, GS-006, GS-007)
space l Direct fitting to
l 10 bar Maximum pressure gas cylinder
l 15 Litre tank for stable air l Comply to British
supply Standards
l 104L/min supply at 3 bar l Supplied with hose
l Easy to ship only 14Kg fitting and crimp
l Various gas cylinder
fittings available
Fume Extraction System
l Regulators for Air,
Acetylene, Argon, LPG
l Specify fitment to
European standard

Acetylene Flame Arrestor (GS-004)


l Direct fitting to gas
regulator output
l Required for acetylene gas
l Non-resetting easy
to replace

l Universal fitting l 240Vac 50/60hz


l Stainless steel l 300mm diameter hood,
construction adjustable height
l All fittings supplied l Adjustable bends from
l 150mm polymer fan 0° to 90°

For more details and ordering information please visit our website www.pginstruments.com 17
AA SPEC BRO – 060_Layout 1 09/10/2013 12:41 Page 19

AA990F
AT O M I C A B S O R P T I O N S P E C T R O M E T E R

The PG990 Atomic Absorption Spectrophotometer is l Agricultural l Geological

a versatile entry level instrument with a computer l Clinical l Petrochemical

controlled Air/Acetylene flame for general laboratory l Environmental l Pharmaceutical

requirements. Due to its high sensitivity and excellent l Food

performance the instrument can be used for a wide l Metal

range of applications including: l Mining

18
AA SPEC BRO – 060_Layout 1 09/10/2013 12:41 Page 20

F E AT U R E S & F U N C T I O N S
l The instrument has a motorised 8 hollow cathode
lamp turret which allows the automatic positioning
and optimisation of each hollow cathode lamp by
the software.
l The control of the gas flows for the fuel gas (C2H2) of
the burner is also carried out directly from the software
thus allowing optimisation of the instrument for the
best analytical parameters for a selected analysis.
l Two methods of background correction are available.
The first utilises a Deuterium Arc lamp and the second
is the proven method of Self Reversal.
l High precision minimal optics ensures maximum light
throughput to the computer controlled Czerny-Turner
Monochromator.
l The location of the wavelength and peak selection is
automatically controlled from the software.
l The spectral bandwidth is automated and is available
with a choice of five slit sizes.
l The electronic parameters for the photomultiplier tube
detector, the hollow cathode lamp current and the
balancing of the absorbance and background energies
are controlled from the software.
l The ignition of the flame is computer controlled
and the various safety interlocks offer a very safe
operating system.

SAFETY
l The flame conditions are continuously monitored and
should the flow rates change, an audible alarm sounds.
l The pressure of the support gas (oxidant) is monitored
constantly. If the pressure changes then the flow of
the fuel gas will be stopped and the flame will be
safely extinguished.
l A sensor monitors the level of liquid in the drain
and will prevent ignition if too low. The flame will also
be extinguished if the level of liquid in the drain
changes significantly.
l A flame sensor monitors the flame and safely turns off the
gas flow to the burner if the flame suddenly extinguishes.
l The burner is identified by a switch making it
impossible to light without the burner being fitted.
l An emergency flame off button is installed in case a
problem is observed. The flame can be extinguished
safely.

19
AA SPEC BRO – 060_Layout 1 09/10/2013 12:41 Page 21

AAWin2 Software
AAWin2 Software is a powerful and intuitive software product designed to
allow control and data acquisition from the PG Instruments PG990 Atomic
Absorption Spectrometer.

The AAWin2 software allows the Analyst to control all


aspects of their analytical method whilst providing an
extensive range of tools for data collection, storage
and interpretation.
The software interface consists of three key work-areas,
whilst having toolbars to access many others. These
work areas allow the user to view real-time signal
acquisition, up-to-date display of calibration curves and
a flexible, sample table.

Lamp turret setup, operating and warm-up currents,


along with the desired analytical wavelength are easily
selected in the configuration.

20
AA SPEC BRO – 060_Layout 1 09/10/2013 12:41 Page 22

Ensure optimal peak position at the chosen analytical


line by scanning the emissions spectra.
Use the sample table to perform quick measurements
of both Standards and Samples.
Easily append the sample table to add new samples
or even revise calibration curves either by manual
introduction or using an Autosampler.

Each stage of analysis setup is made quick and simple


by means of the Sample Wizard.

View up-to-date calibration curves in 1st, 2nd, or 3rd


order using a standard calibration or standard addition.
Perform retrospective curve fits to ensure optimum
correlation.

Obtain reliable and accurate results by using the


View real-time signal acquisition for flame and
Energy control feature to manually optimise atomiser
hydride generation analysis.
position and setup.
Use the Auto-balance feature to ensure energy level.

For more details and ordering information please visit our website www.pginstruments.com 21
AA SPEC BRO – 060_Layout 1 09/10/2013 12:41 Page 23

Specifications
Spectrometer system
Wavelength range 190nm - 900nm
Light Source Hollow cathode lamp (HCL), Deuterium Arc lamp (D2)
Modulation Square Wave Pulse
Modulation frequency 100hz Self reversal (SR) background, 400hz Deuterium Arc (D2) background

Monochromator
Grating 1800 grooves/mm diffraction grating
Blazed Wavelength 250nm
Focus 300nm
Bandwidth 0.1nm, 0.2nm, 0.4nm, 1.0nm, 2.0nm (Software selectable)
Scan mode Automatic
Photometric Type Single Beam
Wavelength Accuracy +/-0.15nm
Wavelength Resolution 0.2nm +/-0.02nm
Wavelength Reproducibility < 0.05nm
Baseline Stability 0.005Abs/30min
Background Correction Deuterium Arc (D2) 1.0Abs, Self Reversal (SR) 3.0Abs
Flame Analysis
Flame Type Air/Acetylene
Sensitivity (Cu) 2ug/ml Absorption >0.28Abs
Characteristic Concentration Cu < 0.02ug/ml
Detection Limit Cu < 0.004ug/ml
Repeatability Cu < 0.7%
Burner head Titanium Alloy
Nebuliser Inert Adjustable Nebuliser, Flow Rate from 2ml - 6ml/min. Pt/Ir capillary
available for high acid concentration
Pre-mix Chamber Corrosion Resistant
Safety Functions Burner switch, Flame Sensor, Gas Leak Sensor, Low Gas Pressure Sensor,
Drain Trap Sensor, Power Loss Protection
Data Processing
Operating Program AA Win software
Analytical Methods Flame AA, Flame AE, Hydride
Readout Mode Continuous, Manual, Peak Height, Peak Area
Calibrations Multi-Standard Calibration, Standard Addition, Interpolation
Data Storage Analytical results, Instrument and measurement parameters, Signal profile,
Calibration curve
Power Requirements 220Vac 50/60hz 200W
Dimensions 110cm x 54cm x 54cm 75Kg

Standard packaging
1 Main Unit 1 Air/Acetylene Burner 1 Gas Tubing Acetylene
1 PG990 Instruction Manual 1 Inert Adjustable Nebuliser 1 Drain Trap and Tubing
1 Cook Book 8 Hollow Cathode Lamp Holders 1 Tool Kit
1 Safety Manual 1 Power Cable 1 Various Gas Fittings
1 System Validation Document 1 Gas Tubing Air

22
AA SPEC BRO – 060_Layout 1 09/10/2013 12:41 Page 24

Accessories
Inert Adjustable Nebuliser (500-011) Flame Autosampler
l Excellent RSD’s typically samples and calibration
Patent pending
<1.0% standards.
l Typical read back values l The system allows for
better than 2% automatic update of
l Enhanced sensitivity standard values and curve
l Can be used on all PG parameters by using up
Instruments AA500 and to 8 standards, blanks
l Acid resistant nebuliser
AA990 series atomic and QC standards.
with Pt/Ir capillary (500-012)
absorption systems l A double wash station
l Adjustable uptake from
l Redesigned spray chamber for probe wash avoids
2-6ml/min
to ensure excellent sample and standard
l Fully adjustable impact
drainage properties l Sequential auto-sampler contamination.
bead
allows the automated l An inert Teflon probe is
analysis of 50 or more supplied as standard.
Hydride Unit (990-007)
l Supplied with
temperature controlled Air Compressor (GS-003)
heated absorption cell l Efficient, Horizontal Twin
l Cell is easily installed with pump unit
burner attachment l Innovative Compact
l Can be used for Mercury Design, perfect for
cold vapour analysis limited space
l Sensitivity for most l 10 bar Maximum pressure
elements <1ng/ml l 15 Litre tank for stable air
l Only 2.0ml – 2.5ml per l Ultra low noise when supply
sample required running – just 53-59dB (A) l 104L/min supply at 3 bar
l Universal design l RSD < 3% l 100% Oil Free Design l Easy to ship only 14Kg
l Full reaction cycle from l Quick analysis < 30
press of start button seconds per measurement

Fume Extraction System l Universal fitting Acetylene Regulator (GS-001)


l Stainless steel construction
l Direct fitting to gas cylinder
l All fittings supplied
l Comply to British Standards
l 150mm polymer fan
l Supplied with hose fitting
l 240Vac 50/60hz and crimp
l 300mm diameter hood, l Various gas cylinder
adjustable height fittings available
l Adjustable bends from l Specify fitment to
0° to 90° European standard

Acetylene Flame Arrestor (GS-004)


l Direct fitting to gas
regulator output
l Required for acetylene gas
l Non-resetting easy
to replace

For more details and ordering information please visit our website www.pginstruments.com 23
AA SPEC BRO – 060_Layout 1 09/10/2013 12:41 Page 25

Atomic Absorption Spectrometer


Qualification Kit

24
AA SPEC BRO – 060_Layout 1 09/10/2013 12:41 Page 26

The purpose of the Qualification Kit is to offer


both laboratory analysts and regional distributors
the flexibility to perform a full installation and
operational qualification on Atomic Absorption
Spectrometers manufactured by PG Instruments.
The work instructions within the qualification work book
have been developed with considerations of the
requirements of the Pharmacopoeia to ensure compliance
with good laboratory practice.
The documentation supplied with the kit, guides the user
through the qualification as it offers detailed instructions
on how to carry out the tests, document and record
results and perform any necessary corrective action. The
comprehensive kit offers all the materials required to
complete the qualification.
The contents of the kit are as follows:
l Qualified Hg Hollow Cathode Lamp – For determining

the wavelength accuracy.

l Qualified Cu Hollow Cathode Lamp – For determining

the flame and graphite analytical tests.

l Qualified Standard Solution – For determining the

flame analytical tests.

l Qualified Standard Solution – For determining the

graphite analytical tests.

l Filter Tool – For determining the photometric

accuracy.

l Certificates for Solutions.

l Qualification Workbook.

l USB Flash Drive containing qualification workbook

and qualification worksheets.

25
AA SPEC BRO – 060_Layout 1 09/10/2013 12:41 Page 27

Atomic Fluoresc
Spectroscopy

26
AA SPEC BRO – 060_Layout 1 09/10/2013 12:41 Page 28

cence The AFS technique is widely used for the


determination of hydride forming elements
and Mercury analysis. The technique provides
an alternative to the conventional method of
connecting a hydride generator to an Atomic
Absorption Spectrophotometer (AAS). Due to
the high intensity Hollow Cathode lamp source
and low baseline noise offered by this
technique, the usable sensitivity is greatly
improved offering very low detection limits.
The AFS instrument fulfils the analysis by means of
simultaneous detection, accurate sample introduction
and stable furnace temperature control complementing
the more widely used AAS flame/graphite systems.

The Atomic Fluorescence Spectroscopy technique is used


to measure samples containing both hydride forming
elements and mercury in a variety of analytical sectors.
Due to its design and functionality, the instrument offers
enhanced sensitivity, reduced interference and excellent
limits of detection (ppt).

27
AA SPEC BRO – 060_Layout 1 09/10/2013 12:41 Page 29

AF402
S I M U LTA N E O U S AT O M I C
FLUORESCENCE SPECTROMETER

28
AA SPEC BRO – 060_Layout 1 09/10/2013 12:42 Page 30

The AF402 is an ideal instrument for elemental


analysis in various market and research
industries including:
l Agricultural l Food and Beverage
l Public Health l Clinical
l Pharmaceutical l Geological
l Metallurgical l Petrochemical

S TA N D A R D F E AT U R E S
Light Source
l High Intensity Hollow Cathode lamps for greater
intensity and stability.
l Up to three lamps can be installed for simultaneous
analysis.
l All lamps are uniquely data coded offering important
information to the PF Win operating software.

Optical System
l Shielded optical design greatly reduces light interference.

l Enhanced signal to noise ratio for increased analytical


sensitivity.
l Unique optical configuration for increased fluorescence
intensity. Up to twice the fluorescence intensity found
in traditional AFS systems.
l High Quantum Solar Blind Photomultiplier Tube fitted
as standard to ensure optimum stability.

Atomiser System
l High precision quartz atomiser tube designed for
optimum performance, durability and long life.
l Self-igniting Argon/ Hydrogen flame with software
controlled heater coil.
l Adjustable height control for improved optimisation.

l Integrated fume exhaust system to decontaminate


pollution.

29
AA SPEC BRO – 060_Layout 1 09/10/2013 12:42 Page 31

AF402
Hydride generator
continued

l Built in Hydride generator with continuous flow.

l Multi-pump with individual pressure adjustment for


uptake control of reagents and carrier liquids.
l Introduction of sample using motorised syringe drive
and unique three way control valve. Software
controlled for greater accuracy.
l High efficiency glass liquid separator which optimises
the separation minimising pressure fluctuations and
improving measurement precision.

Autosampler
l Integrated autosampler.

l XYZ configuration.

l 2 x 45 vial trays for automated sample introduction.

l Auto dilution using motorised syringe drive and


selection valve.
l Full calibration using only one stock standard solution.

l Fully controlled by the PF Win software.

Electronic Control System


l Reagent compartment stores reagents safely and l High technology electronics and PCB components.
cleanly. Storage for up to four containers.
l Rear mounted and separated electronic section to
l Low level reagent monitoring. eliminate carry over from hydride technique.
l Embedded PC system built into the instrument as l Built in embedded PC operating system. No extra
standard. Pre-installed PFWin software, user manual PC control required.
and windows operational system.
l Windows operating software.

l PFWin instrument control software.

Detection Limits
Element Detection Limit(ug/l) RSD %
Arsenic (As) <0.01ug/l <1%
Bismuth (Bi) <0.01ug/l <1%
Cadmium (Cd) <0.001ug/l <1%
Germanium (Ge) <0.05ug/l <1%
Mercury Hg) <0.001ug/l <1%
Lead (Pb) <0.01ug/l <1%
Antimony (Sb) <0.01ug/l <1%
Selenium (Se) <0.01ug/l <1%
Tin (Sn) <0.01ug/l <1%
Tellurium (Te) <0.01ug/l <1%
Zinc (Zn) <1.0ug/l <1%

30
AA SPEC BRO – 060_Layout 1 09/10/2013 12:42 Page 32

PFWinSoftware
The intuitive software package provides ease of
operation, method development control and data
acquisition. Software wizards simplify the operation
and configuration.

Detailed information and results are shown for each


element analysed.

Calibration information as well as results for standards


are shown for each element.

AFWin offers real time display of fluorescence intensity.


Full adjustment of current for all hollow cathode lamps
is provided. Lamps are set for optimal performance.

Detailed results for the analysis can be seen and saved.


Reporting and QC control allows printouts of spectra,
standard calibration curves, analysis and signal data.
Report of operating parameters can be saved or printed
Where parameters are input manually, PFWin software
for future information.
will prompt the suggested parameters to complete the
configuration for the analysis.

31
AA SPEC BRO – 060_Layout 1 09/10/2013 12:42 Page 33

Specifications
Sample Atomisation
Atomiser Quartz tube furnace with auto ignition of argon/hydrogen flame
Furnace heating Computer controlled heating
Hydride Generator Continuous flow high performance for cold-vapour mercury and hydride
determinations of As, Se, Te, Bi, Sb, Sn, Zn, Pb, Cd, Ge
Gas Requirement High purity Argon gas(99.99%) 30psi pressure

Sample and delivery


Peristaltic Pump 3 channel pump with 3 adjustable pressure control clamps and programmable
speed control.
Exhaust System Built in with filter to decontaminate pollutants
Gas/Liquid Separator High efficiency two-stage gas-liquid separator.

Autosampler
Type Integrated XYZ
Sample Introduction High sample capacity, automated introduction of sample and standards by
motorised syringe drive.
Sample capacity 2 x 45 standard test tube sample racks

Optics
Optical Design Short focal length, non-dispersive integrated optical design.
Light source 3 channel simultaneous element analysis using computer controlled.
Modulated and pulsed, hollow cathode light source.
Baseline stability <2%
Linear range >103

Computer system
Type Built in embedded PC system
Operating system Windows
Operating software PFWin software

Safety Alarm for low gas <60ml/min. Gas cut off in the event of power supply loss
Power requirements 220Vac ±10% 50/60hz, 300W
Dimensions 100.6cm x 58cm x 55cm

32
AA SPEC BRO – 060_Layout 1 09/10/2013 12:42 Page 34

Accessories
Argon Gas Regulator
l Direct fitting to gas cylinder

l Comply to British Standards

l Supplied with hose fitting and crimp

l Various gas cylinder fittings available

l Regulator for high purity Argon 99.99%

l Specify fitment to European standard

Fume Extraction System


l Universal fitting

l Stainless steel construction

l All fittings supplied

l 150mm polymer fan

l 240Vac 50/60hz

l 300mm diameter hood, adjustable height

l Adjustable bends from 0° to 90°

For more details and ordering information please visit our website www.pginstruments.com 33
AA SPEC BRO – 060_Layout 1 09/10/2013 12:42 Page 35

FP902
FLAME PHOTOMETER

34
AA SPEC BRO – 060_Layout 1 09/10/2013 12:42 Page 36

NW U
BA

O ITH M
W
RI
Flame photometry provides a simple method
of analysis and concentration determination of
elements which cannot easily be measured
using any other technique. PG Instruments
application notes for users of our versatile
new flame photometers cover a wide range
of industrial sectors, from food and drink to
cement, minerals and glass, as well as
agricultural, biological and clinical applications.

The PG Instruments FP902 Flame Photometer offers


the combination of clinical, industrial and education
applications in ONE instrument. It gives accurate, fast and
precise analysis of sodium, potassium, calcium and lithium
in one simple aspiration.

The FP902 uses a soft touch key pad for ease of data entry
and features electronic ignition, automatic flame failure
safety and will operate using butane, natural gas or LPG.

35
AA SPEC BRO – 060_Layout 1 09/10/2013 12:42 Page 37

T Y P I C A L A P P L I C AT I O N S
l Soil and Agricultural Analysis
l Biological Fluids

l Petrochemical Industry

l Food and Drink Analysis

F E AT U R E S & F U N C T I O N S
l Five element measurement in a single aspiration
(Na, K, Li, Ca and Ba).
l Curve calibration using up to 5 standards.

l Calibration curve fit routines first order and


second order.
l Multiple calibration curve saving facility.

l Sample data storage.

l Printer attachment.

l Data displayed in concentration units ie. ppm,


meq etc.

36
AA SPEC BRO – 060_Layout 1 09/10/2013 12:42 Page 38

Specifications
General Analytical
Mode Applications Serum Urine

Na: 0.1-100 ppm Na: 0-200 Na: 0-250


Up to 250 meq/l, 1:100 dil 1:100 dil 1:100 dil
K: 0.1-100 ppm K: 0-10 K: 0-100
Up to 250 meq/l, 1:100 dil 1:100 dil 1:100 dil
Range
Ca: 15-100 ppm Ca: - Li: 0-2 Ca: - Li: 0-10
Up to 250 meq/l, 1:100 dil 1:5 dil 1:2 dil
Li: 0.5-100 ppm
Up to 250 meq/l, 1:100 dil
Sensitivity General Mode: Na:0.5 ppm, K:0.5 ppm, Li:0.5 ppm, Ca:15 ppm, Ba:30 ppm
Filters Filters for Sodium, Potassium, Lithium, Calcium and Barium are included
Resolution 0.1 ppm/meq
Reproducibility + 2% FS, & + 2 Digits
Curve Fit Accuracy + 2% FS
Display 20 x 4 Alphanumeric backlit LCD display
Flame System LPG & dry oil free air
Detector Silicon Photodiode
Calibration Up to 5-Point Calibration with curve fitting software
Gas Control Fully Adjustable
Ignition System Auto Ignition
Atomiser Axial flow type
RS-232C Interface RS-232 PC Software available
Power 230 V + 10% AC, 50/60 Hz
Dimensions 365 x 245 x 220 mm (L x B x H) (Approx.)
Weight Main Unit: 7.5Kg. (Approx.)

Compressor Unit
Air Supply Oil free compressor unit with pressure regulator
Combustion Gas LPG Controlled by precision regulator
Power 230 V + 10% AC, 50/60 Hz
Dimensions 290 x 255 x 210 mm (L x B x H) (Approx)
Weight 8Kg. (Approx.)

37
AA SPEC BRO – 060_Layout 1 09/10/2013 12:42 Page 39

Consumables
AA500
Hollow Cathode Lamps Multi Element Standards
l 2 inch lamps available l 500ml volume bottles
l 70 single-element lamps l More than 40 individual
l More than 120 multi elements available
element lamps, up to l 1.000g/ml (1000ppm)
5 element per lamp concentration
l Low current operation l Individual elements made
l Long life >5000mA Hours up in a choice of acid
l 11/2 inch standard lamp l Designed for use with SR solutions
fitting background system

Glass Fixed Flow Nebuliser Standard Nebuliser (Acid Resistant available)


l Glass construction l Excellent RSD’s typically
l Fixed flow rate for easy <1.0%
installation. l Typical read back values
l Acid resistant to 5% better than 2%
l Easily replaced l Enhanced sensitivity
l Can be used on all PG
Instruments AA500 and
l Fully insert nebuliser AA990 series atomic
l Adjustable uptake from absorption systems
2-6ml/min l Redesigned spray chamber
l Fully adjustable impact to ensure excellent
bead drainage properties

Graphite Tubes Sample Uptake Tubes


l Pyrolytically coated l Replacement sample
graphite tube uptake tubes
l Supplied with or without l Attached filter to eliminate
platform solid uptake
l High quality long life tubes l Standard length
l Can be used for larger l Easily replaced
samples >20ul

Deuterium Lamp Auto Sampler Vials – Flame Samples


l High energy lamp l Re-useable glass vials
l For use with AA500 l For use with AS500 Auto
instrument Sampler
l Easy fit l Larger volume for samples
l No alignment required 6ml

38
AA SPEC BRO – 060_Layout 1 09/10/2013 12:42 Page 40

Consumables
AA500
Auto Sampler Vials – Flame Standards Auto Sampler Vials – Graphite Samples/Standards
l Re-useable glass vials l Re-usable vials
l For use with AS500 Auto l For use with AS500
Sampler autosampler
l Larger volume for l 1.5ml volume for samples
standards 12ml and standards

Auto Sample Vials – Graphite Modifier Solutions Micro Pipette


l Re-useable glass vials l Used for manual injection
l For use with AS500 Auto l Adjustable volume
Sampler l Accurate dispensing
l Larger volume for modifier volume
solution 12ml l For use with AA500
Graphite Furnace

Micro Pipette Tips


l Disposable tips
l For use with micro pipette

39
AA SPEC BRO – 060_Layout 1 09/10/2013 12:42 Page 41

Consumables
AA990
Hollow Cathode Lamps Multi Element Standards
l 2 inch lamps available l 500ml volume bottles
l 70 single-element lamps l More than 40 individual
l More than 120 multi elements available
element lamps, up to l 1000g/ml (1000ppm)
5 element per lamp concentration
l Low current operation l Individual elements made
l Long life >5000mA Hours up in a choice of acid
l 11/2 inch standard lamp l Designed for use with SR solutions
fitting background system

Glass Fixed Flow Nebuliser Acid Resistant Nebuliser


l Glass construction l Excellent RSD’s typically
l Fixed flow rate for easy <1.0%
installation. l Typical read back values
l Acid resistant to 5% better than 2%
l Easily replaced l Enhanced sensitivity
l Can be used on all PG
Instruments AA500 and
l Fully insert nebuliser AA990 series atomic
l Adjustable uptake from absorption systems
2-6ml/min l Redesigned spray chamber
l Fully adjustable impact to ensure excellent
bead drainage properties

Sample Uptake Tubes Deuterium Lamp


l Replacement sample l High energy lamp
uptake tubes l For use with AA500
l Attached filter to eliminate instrument.
solid uptake l Easy fit
l Standard length l No alignment required.
l Easily replaced

Auto Sampler Vials – Flame Samples/Standards Auto Sampler Vials – Wash


l Re-useable glass vials l For use with AS990 Auto
l For use with AS990 Auto Sampler
Sampler l Large volume for wash
l Larger volume for samples l Re-usable

40
AA SPEC BRO – 060_Layout 1 09/10/2013 12:43 Page 42

Consumables
AF402
Hollow Cathode Lamps Quartz Atomiser
l High performance – High l Quartz Glass – to
output lamps withstand heat and
l Lamps designed for use chemicals
with AF402 system l Replacement required at
l Built in circuit for coding regular intervals
and usage recording l Inputs for gas and hydride
l Available for analysis of a vapout
variety of elements
including: Sb, As, Bi, Cd,
Ge, Pb, Hg, Se, Te, Sn, Zn

Injection Tubes Glass Mixing Chamber


l Quartz Glass – to l Quartz glass
withstand high acid l Built in gas separator
solutions l Easily replaced
l Designed to fit in the XYZ
autosampler

Heater Coils Syringe


l Replacement wire coils l Accurate high quality
l Fits around the Quartz l Used for accurate uptake
Atomiser of sample and carrier liquid
l Used for heating the l Requires regular flushing
atomiser when used for
hydride analysis
l Regular replacement
suggested

Sample Cups Small Standard Solutions


l Re-usable glass cups l 500ml volume bottles
l Used in XYZ autosampler l Individual elements
for standard solutions available for Sb, As, Bi, Cd,
Ge, Pb, Hg, Se, Te, Sn, Zn
l 1.000g/ml (1000ppm)
concentration

41
AA SPEC BRO – 060_Layout 1 09/10/2013 12:43 Page 43

Consumables
FP902
Air Compressor Nebuliser
l Matching air compressor l Cross flow design
l Adjustable uptake rate
designed only for use with

l High quality capillary tube


FP902 instrument
l Oil free air
l Adjustable air supply with
gauge
l 220v 50/60hz

Burner Capillary Tubes


l Fits into premix chamber l Fit onto capillary tube of
l Designed for use with low nebuliser
pressure propane flame l Optimised length
l Easily removed for cleaning l Used for sample uptake
l Easily fitted and replaced

Cleaning Wires Sample Cups


l Fine wire length l Re-usable glass cups
l Used to clean blockage in l Used for holding samples
capillary tube of nebuliser and standard solutions
l Small volume size for use
with FP902 instrument

42
AA SPEC BRO – 060_Layout 1 09/10/2013 12:43 Page 44

We reserve the right to modify, revise/upgrade, suspend or discontinue any Product in whole or in part,
either temporarily or permanently, with or without notice.
AA SPEC BRO – 060_Layout 1 09/10/2013 12:40 Page 1

instruments
ALMA PARK, WIBTOFT
LEICESTERSHIRE, LE17 5BH
UNITED KINGDOM
T: +44 (0)1455 220131
F: +44 (0)1455 220025
www.pginstruments.com

V1.2013

You might also like