REPLACER TM IGNITOR KIT

APPLICATIONS
ROADWAY LIGHTING

• A replacement for ignitors in HPS fixtures (having adequate space) of 35 through 400 watts
SPECIFICATION FEATURES
• Self-contained high voltage pulse generator
• Plug-in design
• Useable with 35 through 400 watt HPS lamps
• Comes complete with installation hardware and instructions
• Proven GE quality and high reliability
• Factory burn-in before shipment
• Two lead design - no ballast tap required

ORDERING INFORMATION
• REPLACER IGNITOR KIT
Ordering Number 35-967410-51 (Includes all installation components)
• REPLACER IGNITOR ONLY*
Ordering Number 35-216710R01*
*Primarily for fixtures with existing GE built-in plug-in ignitor
capability

APPLICATION INFORMATION
As the APPLICATION TABLE below shows, when installing GE Replacer
Ignitors:
• Leave Jumper in place for 52-55 volt HPS lamps of 35 through 150
watts
• Cut Jumper for 90-100 volt HPS lamps of 70 through 400 watts
CAUTION: FAILURE TO CUT JUMPER WHEN REQUIRED CAN
CAUSE IGNITOR FAILURES.

FIXTURE DIMENSIONS APPLICATION TABLE


ANSI LAMP LAMP DO NOT
LAMP TYPE WATTAGE VOLTAGE CUT JUMPER CUT JUMPER
S76 35 52 X
S68 50 52 X
S62 70 52 X
S88 70-90 90 X
S54 100 55 X
S55 150/55 55 X
S56 150/100 100 X
S66 200 100 X
S50 250 100 X
S67 310 100 X
S51 400 100 X

CIRCUIT DIAGRAM