:Example
Size a Horizontal separator with a mist eliminator
pad to separate the following mixture .

The operating pressure is 975 psig and the holdup


and surge are to be 10 min and 5 min respectively.
Use a design temperature of 650°F .

https://docs.google.com/presentation/u/1/d/1DkjyG4cRtGI3Df45aQnpMizzt4v0qhdBumogDd1_k2c/htmlpresent 3/20
5/10/2019 Two Phase Horizontal Separator - Design Procedure.ppsx - Google Slides

Design Procedure: :Example

https://docs.google.com/presentation/u/1/d/1DkjyG4cRtGI3Df45aQnpMizzt4v0qhdBumogDd1_k2c/htmlpresent 4/20
5/10/2019 Two Phase Horizontal Separator - Design Procedure.ppsx - Google Slides

Design Procedure: :Example

https://docs.google.com/presentation/u/1/d/1DkjyG4cRtGI3Df45aQnpMizzt4v0qhdBumogDd1_k2c/htmlpresent 5/20
5/10/2019 Two Phase Horizontal Separator - Design Procedure.ppsx - Google Slides

Design Procedure: :Example


7)
7. HLLL = 0.5×5+7
= 9.5 in.

8)
x = HLLL/D =0.158
From Eq. → y = 0.102 → ALLL/AT = 0.102
→ ALLL =0.102×19.63 = 2 ft2.

Design Procedure: :Example

https://docs.google.com/presentation/u/1/d/1DkjyG4cRtGI3Df45aQnpMizzt4v0qhdBumogDd1_k2c/htmlpresent 6/20
5/10/2019 Two Phase Horizontal Separator - Design Procedure.ppsx - Google Slides

Liquid Inventory Length:

https://docs.google.com/presentation/u/1/d/1DkjyG4cRtGI3Df45aQnpMizzt4v0qhdBumogDd1_k2c/htmlpresent 7/20
5/10/2019 Two Phase Horizontal Separator - Design Procedure.ppsx - Google Slides

Av

https://docs.google.com/presentation/u/1/d/1DkjyG4cRtGI3Df45aQnpMizzt4v0qhdBumogDd1_k2c/htmlpresent 8/20
5/10/2019 Two Phase Horizontal Separator - Design Procedure.ppsx - Google Slides

A(holdup+surge) AT
+
ALLL

Liquid Inventory Length (L) vs Separation Length (LMIN)

https://docs.google.com/presentation/u/1/d/1DkjyG4cRtGI3Df45aQnpMizzt4v0qhdBumogDd1_k2c/htmlpresent 9/20
5/10/2019 Two Phase Horizontal Separator - Design Procedure.ppsx - Google Slides

Liquid Inventory Length (L) vs Separation Length (LMIN)

Design Procedure: :Example


https://docs.google.com/presentation/u/1/d/1DkjyG4cRtGI3Df45aQnpMizzt4v0qhdBumogDd1_k2c/htmlpresent 10/20
5/10/2019 Two Phase Horizontal Separator - Design Procedure.ppsx - Google Slides

Design Procedure: :Example


L > 1.2 ×LMIN → L >> LMIN
Type:

https://docs.google.com/presentation/u/1/d/1DkjyG4cRtGI3Df45aQnpMizzt4v0qhdBumogDd1_k2c/htmlpresent 11/20
5/10/2019 Two Phase Horizontal Separator - Design Procedure.ppsx - Google Slides

Calcula on of thickness of Head & Shell


:Design Pressure & Design Temperature

Reference: RULES OF THUMB: SUMMARY , Walas Click to see contents:

1. Design temperature between -20°F and 650°F is 50°F above opera ng temperature; higher safety
margins are used outside the given temperature range.
If -20 oF <OT < 650 oF → DT=OT + 50 oF

https://docs.google.com/presentation/u/1/d/1DkjyG4cRtGI3Df45aQnpMizzt4v0qhdBumogDd1_k2c/htmlpresent 12/20
5/10/2019 Two Phase Horizontal Separator - Design Procedure.ppsx - Google Slides

2. The design pressure is 10% or 10-25 psi over the maximum opera ng pressure, whichever is greater.
The maximum opera ng pressure, in turn, is taken as 25 psi above the normal opera on.
MOP= NOP+25 psi DP=max.{1.1×MOP , MOP+10~25 psi}

3. Design pressures of vessels opera ng at 0-10 psig and 600-1000°F are 40 psig.

Calcula on of thickness of Head & Shell


P, design pressure, psig
Typically,
opera ng pressure+(15-30) psi or 10-15%, whichever
greater.

T, design temperature , oF
Typically,
if Top > 200°F, DT=opera ng temperature +25-50°F.
If Top < 200°F, DT=250°F

• under 650°Fdoesnot reduce wall thickness


• if overpressure caused by boiling, should be TBP .

https://docs.google.com/presentation/u/1/d/1DkjyG4cRtGI3Df45aQnpMizzt4v0qhdBumogDd1_k2c/htmlpresent 13/20
5/10/2019 Two Phase Horizontal Separator - Design Procedure.ppsx - Google Slides

Allowable Stress of Alloy


Pressure Vessel Handbook-
Megyesy
Evaluate Design Temperature for the selected alloy
and then read S from the Table.

https://docs.google.com/presentation/u/1/d/1DkjyG4cRtGI3Df45aQnpMizzt4v0qhdBumogDd1_k2c/htmlpresent 14/20
5/10/2019 Two Phase Horizontal Separator - Design Procedure.ppsx - Google Slides

Design Procedure: :Example


Tips:
According to Walas Rules of Thumbs DT = 650 oF
for Pressure Vessels NOP=975 psig
→ MOP=975+25=1000 psig
Corrosion allowance:
0.35 in. for known corrosive conditions, → DP=max{1000+25, 1.1×1000}=1100 psig
0.15 in. for non-corrosive streams, and
0.06 in. for steam drums and air receivers. Alloy: SA 516 70 Carbon Steel

→ From Table: 17.5 → S= 17500 psi

Let C.A. tC= 1/16 = 0.06 in. & Joint Efficiency (E) = 0.85

Head Type:
D < 15 ft. & P > 100 psig → 2:1 Elliptical

Design Procedure: :Example


15)
Head Thickness & Area:
https://docs.google.com/presentation/u/1/d/1DkjyG4cRtGI3Df45aQnpMizzt4v0qhdBumogDd1_k2c/htmlpresent 15/20
5/10/2019 Two Phase Horizontal Separator - Design Procedure.ppsx - Google Slides

Shell Thickness & Area:

Alloy plate thickness:

16)

17)

Design Procedure:

https://docs.google.com/presentation/u/1/d/1DkjyG4cRtGI3Df45aQnpMizzt4v0qhdBumogDd1_k2c/htmlpresent 16/20
5/10/2019 Two Phase Horizontal Separator - Design Procedure.ppsx - Google Slides

:Example

Nozzles Orientation:

https://docs.google.com/presentation/u/1/d/1DkjyG4cRtGI3Df45aQnpMizzt4v0qhdBumogDd1_k2c/htmlpresent 17/20
5/10/2019 Two Phase Horizontal Separator - Design Procedure.ppsx - Google Slides

Nozzle Sizing: :Example

Liquid Outlet:
U=1~4 m/s (min 2”).

Vapor Outlet:
U=15~30 m/s or ρU2 = 3750 Pa.
→DV=6”

https://docs.google.com/presentation/u/1/d/1DkjyG4cRtGI3Df45aQnpMizzt4v0qhdBumogDd1_k2c/htmlpresent 18/20
5/10/2019 Two Phase Horizontal Separator - Design Procedure.ppsx - Google Slides

https://docs.google.com/presentation/u/1/d/1DkjyG4cRtGI3Df45aQnpMizzt4v0qhdBumogDd1_k2c/htmlpresent 19/20
5/10/2019 Two Phase Horizontal Separator - Design Procedure.ppsx - Google Slides

Home Work: :References


Design a Horizontal flash drum by considering below condi ons.
Feed enters at 5 barg & 40 oC.
Vapor density is 8 kg/m3 & liquid density is 780 kg/m3.
Flow rate of feed is 12,000 kg/hr. 1. Wayne D. Monnery and William Y. Svrcek.
"Design Two-Phase Separators Within The
Feed is non corrosive, use your own assump on during sizing. Right Limits"; ,University of Calgary; October
Report required data as much as possible. 1993. Chemical Engineering Progress (CEP).

Assume previous (Vertical H.W.) assumptions and compare the both


design cases.
2. Eugene F. Megyesy. "Pressure Vessel
Handbook", 10th Edition, University of Tulsa,
1) Unit Feed Drum with q=40% , with Mesh pad. 1997.
2) Flare K.O. Drum with q=0 , without Mesh pad
3) Unit Feed Drum with q=40% and without mesh pad.
4) Unit Feed Drum with q=80%, with mesh pad. 3. Stanley M. Walas, "Chemical Process
5) Unit Feed Drum with q=100%, with mesh pad. Equipment Selection and Design", University
of Kansas, 1990.
Extra Example:
Slug catcher with q=20% and 40 m3 slug volume as unit feed drum.