could result in a misleading well and reservoir performance, in particular with low to mid
permeability reservoirs. As a matter of fact, there is no other alternative to PBU/PFO tests so
as to get KH and skin under transient behaviour.
Complex deliverability tests are passed their due date, in particular with well testing. Experts
in several majors agree: fancy deliverability tests are no longer run in well test operations, and
for good reasons.
Isochronal test:
The operator flows the well at different rates for the same duration ∆T, each separated by a
PBU test. Each shut-in needs to be long enough to reach the stabilized average reservoir
pressure.
The flowing periods are of same duration ∆T, which could be of 3 hours for example. As the
rate increases, the consecutive shut-in needs to be longer so as to reach the stabilized initial
pressure or average reservoir pressure.
In practice for low to mid permeability reservoirs, this test is also not feasible since the shut-
in duration would be too long to reach stabilized reservoir pressure. If too short, the results for
this deliverability test on these types of reservoirs could be misleading.
The duration of this complex deliverability test could be shortened with the modified
isochronal test with an increasing step rate test.
As a matter of fact, the skin can only be derived from a PBU analysis.
The well and reservoir performance should be derived from well test analysis on several
PBUs.
Everything can be obtained from 2 PBU tests: permeability and skin, the different skin
elements, initial pressure, heterogeneities, hydrocarbon volume, distances to the boundaries,
etc… All this information can then be used to build the IPR, for example.
In a well test design study, you should forget about adding a complex deliverability test but
focus on two PBU tests and make sure the shut-ins are long enough to derive a reliable
deconvolution.
Short step rate test to obtain the non-darcy skin
More (reliable) information is extracted from PBU analysis than from any deliverability test.
The only test that you should be interested in is a simple increasing step rate test for gas and
gas condensate wells.
This is different from the flow-after-flow test because we don’t need to wait for pseudo-
steady state. We only need to flow for a couple of hours and make sure that radial flow regime
is at least reached for each step (and not dominated by wellbore storage effects).
For dry gas and gas condensate wells, a short flow-after-flow test (3 increasing step rate tests)
can be designed to evaluate the turbulence factor (non-darcy skin).
This test is not to define the inflow performance relationship (IPR), but to extract the
turbulence (or non-darcy skin element). As a consequence, the criteria shouldn’t be to wait for
pseudo-steady state and the test can be shortened to a couple of hours.
In the well test analysis workflow, we first need to match all the PBUs, as shown below.
(It is worth noticing the “depletion” trend in the PBUs. This doesn’t mean that the reservoir is
closed and reservoir pressure changes. In this case, it only supports the presence of
boundaries).
Once all the PBUs are matched, the user can match the short step rate test by tweaking the
non-darcy skin.
By increasing the turbulence factor while decreasing the mechanical skin to keep the total
skin constant, we obtain a match on the deliverability test.
The first flow period from 20 to 40 hours cannot be matched and shows that the skin in our
model is too low during that period. In reality, the actual skin was larger at the beginning of
the test and the well is slightly cleaning up.
Some well test softwares, such as Saphir and PIE, offer an option to automatically calculate
the non-darcy skin based on the short step rate test.
Step rate test can be dominated by wellbore dynamic effects and not be representative of
the well and reservoir.
Several flow periods in the step rate test can be dominated by a changing fluid density below
the gauge. We need to place the pressure gauge as close as possible to the perforations and be
cautious when matching the test.
After a well test analysis, your model should match the several PBUs and the step rate test, as
shown below.
But in this particular case with a vertical well, the total skin is about 1.5 while the mechanical
skin is about -3. This is a red flag that the step rate test is not reliable and the data are affected
by some dynamic effects in the wellbore.
This is probably because the two first flow periods are affected by a different fluid density
below the gauge.
The turbulence factor that is derived from this analysis won’t be correct and will be over-
estimated.
As the fluid density below the gauge changes during each step, you should not expect to
match all the 3 rate steps with one value of non-darcy skin. This deliverability test cannot be
used.