You are on page 1of 2

IMPACT 4.00.51.

00-SNAPSHOT 08/10/18

Chassis ID Path
A 709392 5618/Diagnostics//Air drier, function check

Model Identity
FH 117583574

Publish date ID/Operation


09/04/08 56133-2

56133-2 Air drier, function check

AIRDRY VERSION2 AIRDRY1 VERSION2

Part number: Läckagesökare 1161900

Special tools: 9992976, 9996461, 9996465, 9996926

Other special equipment: 1159680

Caution
Follow the instructions carefully to avoid personal injury and damage to the product or equipment.

Note: Make sure that the parking brake is applied.

Empty the air out of the compressed air system, use nipple 9992976.

Special tools: 9992976

Copyright to this documentation belongs to the Volvo Group. No reproduction, copying, change, amendment or other similar disposal is entitled without prior written consent by
the Volvo Group
The information contained herein is current at the time of its original distribution, but is subject to change. The reader is advised that printed copies are uncontrolled.

1/2
IMPACT 4.00.51.00-SNAPSHOT 08/10/18

Connect manometer 9996465 or 9996926 (depending on the system pressure) to the primary reservoir on the vehicle
using nipple 9992976 and hose 9996461.

Note: Do not use the manometer on the instrument panel.

Special tools: 9992976 9996461 9996465 9996926

4
Fit an exhaust hose. Start the engine.

5
When system pressure has been reached open the built-in relief valve. The air from the regeneration reservoir flows
from the air dryer together with water and any oil via the relief valve and the silencer. Check the cut-out pressure when
air dryer discharges. For the correct cut-out pressure see service information Air dryer, specifications in group 56.

6
Lower the system pressure slowly. Check the connection pressure. The connection pressure is the pressure that the
system has at the same moment as the relief valve closes and the compressor starts to charge the system again. For
the correct cut-in pressure see service information Air dryer, specifications in group 56.

7
Start the engine. Charge the pressure in the tanks. Check that the safety valve and air dryer connections are airtight
using leak tracing instrument 1159680 or soapy water 1161900 . Turn off the engine. Remove the exhaust hose.

Special tools: 1159680 1161900

Copyright to this documentation belongs to the Volvo Group. No reproduction, copying, change, amendment or other similar disposal is entitled without prior written consent by
the Volvo Group
The information contained herein is current at the time of its original distribution, but is subject to change. The reader is advised that printed copies are uncontrolled.

2/2