VIESMANN VITOTRANS 353

Type PBS, PZS, PBM, PZM and PBL

System examples

Selected system examples

5517 115 GB 4/2014


Index

Index
1.
DHW heating with Vitotrans 353 freshwater module, type PZS/PZM for
cylinder mounting and heating water buffer cylinder ................................. 4

ID: 4611317_1404_01

2.
DHW heating with Vitotrans 353 freshwater module, type PZS/PZM for
cylinder mounting, heating water buffer cylinder and solar function .......... 6

ID: 4611316_1404_01

3.
DHW heating with Vitotrans 353 freshwater module, type PBS/PBM/PBL
for wall mounting and heating water buffer cylinder .................................. 9

ID: 4611319_1404_01

4.
DHW heating with Vitotrans 353 freshwater module, type PBS/PBM/PBL
for wall mounting and heating water buffer cylinder, with solar function . . . 11

ID: 4611318_1404_01

5.
DHW heating in 2-module cascade, comprising Vitotrans 353 freshwater
modules, type PBM/PBL for wall mounting and heating water buffer cylin-
der, with solar function ............................................................................... 14

ID: 4611314_1404_01

6.
DHW heating in 4-module cascade, comprising Vitotrans 353 freshwater
modules, type PBM/PBL for wall mounting and heating water buffer cylin-
der ............................................................................................................. 17

ID: 4611312_1404_01
5517 115 GB

2 VIESMANN VITOTRANS 353


Explanatory notes on the diagrams

Numbering of technical components and electrical connections

qR
--11/S5--

--11/S5-- qR

qQ
--S5--

9
[G
S
10
qQ
--L--
--R1--
--230V--
--R2--
5517 115 GB

VITOTRANS 353 VIESMANN 3


ID: 4611317_1404_01

1. DHW heating with Vitotrans 353 freshwater module, type PZS/PZM for cylinder mount-
ing and heating water buffer cylinder
1
The freshwater module provides DHW heating when hot water is
drawn or during DHW circulation. Control unit qQ controls the DHW
heating according to demand via combined DHW temperature and
flow control.
The DHW is heated in freshwater module qP according to the instan-
taneous water heater principle. An internal pump transfers the heating
water from heating water buffer cylinder 1 into freshwater module
qP. The heat exchanger in freshwater module qP heats the DHW
according to the countercurrent principle.
In freshwater modules for cylinder mounting, the DHW circulation
ID: 4611317_1404_01 pump and the return distribution set are installed at the factory.

Note
Application This scheme is a general system example. Please refer to the
Detached/two-family houses with corresponding DHW demand appropriate technical guides when planning specific applica-
tions.
Main components
■ Vitotrans 353, type PZS, PZM
■ Heating water buffer cylinder

Function description

DHW heating
The freshwater module is supplied with energy by the heating water
buffer cylinder. This is heated by heat source 2.

ID: 4611317_1404_01
Vitotrans 353 coding address
Assembly Code Function
DHW circulation "DHW circulation type/thermal/thermal + Activation of DHW circulation
demand"

Hydraulic installation scheme ID: 4611317_1404_01

WW

--3/STS--
6
KW 11
--L--

--R2--
--230V--

46

10 2

Note: This scheme is a general example without shut-off valves or safety equipment. This does not replace the need for on-site engineering.
5517 115 GB

4 VIESMANN VITOTRANS 353


ID: 4611317_1404_01 (cont.)

Equipment required

ID: 4611317_1404_01
Pos. Designation Part no.
1
Heating water supply
1 Heating water buffer cylinder See Viessmann pricelist
2 Connection to the heat source On site
DHW heating by freshwater module
qP Vitotrans 353 freshwater module for cylinder mounting, type PZS with draw-off rate up to 25 l/min Z012 823
or
Vitotrans 353 freshwater module for cylinder mounting, type PZM with draw-off rate up to 48 l/min Z012 824
qQ Integral control unit Standard delivery pos. 10
rZ Temperature sensor for heating of the heating water buffer cylinder by the heat source Standard delivery pos. 2

Electrical installation scheme

11 Vitotrans 353

N
230V/50Hz
L
L'
N M
1~
ZP 12

L'
N

L
230V/50Hz

R1 N

L
R2 N

L
R3 N

R4
Low voltage

9
S5 10

23
PWM2 24

ID: 4611317_1404_01
5517 115 GB

VITOTRANS 353 VIESMANN 5


ID: 4611316_1404_01

2. DHW heating with Vitotrans 353 freshwater module, type PZS/PZM for cylinder mount-
ing, heating water buffer cylinder and solar function

In freshwater modules for cylinder mounting, the DHW circulation


pump and the return distribution set are installed at the factory.
The heating water buffer cylinder is additionally heated by the solar
thermal system.

Heating water heating with solar energy


2 If the temperature differential between solar collector sensor 5 and
cylinder temperature sensor 6 exceeds the start temperature differ-
ential, solar circuit pump 8 starts and heating water buffer cylinder
1 is heated.
ID: 4611316_1404_01 Solar circuit pump 8 is deactivated according to the following crite-
ria:
■ The stop temperature differential is undershot
Application ■ The electronic temperature limit of the control unit is exceeded (max.
Detached/two-family houses with solar DHW heating 90 °C) 7
■ The temperature selected at high limit safety cut-out rQ (if installed)
Main components is reached
■ Vitotrans 353, type PZS, PZM If there is sufficient insolation, the entire heating water buffer cylinder
■ Heating water buffer cylinder 1 is heated by the solar thermal system.
■ Solar thermal system The upper part of heating water buffer cylinder 1 is only reheated by
boiler 2 if the actual water temperature falls below the set tempera-
Function description ture selected at the boiler control unit.

DHW heating Note


The freshwater module is supplied with energy by the heating water This scheme is a general system example. Please refer to the
buffer cylinder. This is heated by heat source 2 or by solar collectors appropriate technical guides when planning specific applica-
4. tions.
The freshwater module provides DHW heating when hot water is
drawn or during DHW circulation. Control unit qQ controls the DHW
heating according to demand via combined DHW temperature and
flow control.
The DHW is heated in freshwater module qP according to the instan-
taneous water heater principle. An internal pump transfers the heating
water from heating water buffer cylinder 1 into freshwater module
qP. The heat exchanger in freshwater module qP heats the DHW
according to the countercurrent principle.

ID: 4611316_1404_01
Vitotrans 353 coding address
Assembly Code Function
DHW circulation "DHW circulation type/thermal/thermal + Activation of DHW circulation
demand"
5517 115 GB

6 VIESMANN VITOTRANS 353


ID: 4611316_1404_01 (cont.)

Hydraulic installation scheme ID: 4611316_1404_01

--3/KTS-- 4

2
WW

7
9
--STS--

--KTS--
--145--

3
--UPS--
--230V--

1 46

--3/STS--
6
KW 11
--L--

--R2--
--230V--

10 2

Note: This scheme is a general example without shut-off valves or safety equipment. This does not replace the need for on-site engineering.

Equipment required

ID: 4611316_1404_01
Pos. Designation Part no.
Heating water supply
1 Heating water buffer cylinder See Viessmann pricelist
2 Connection to the heat source On site
3 Solar control unit, type solar module SM1, Vitosolic 100 type SD1 or Vitosolic 200 type SD4 See Viessmann pricelist
4 Collectors See Viessmann pricelist
5 Solar collector sensor Standard delivery pos. 3
6 Cylinder temperature sensor STS (solar) Standard delivery pos. 3
7 Solar-Divicon, for installation on the cylinder See Viessmann pricelist
8 Solar circulation pump Standard delivery pos. 7
9 High limit safety cut-out STB Z001 889
DHW heating by freshwater module
qP Vitotrans 353 freshwater module for cylinder mounting, type PZS with draw-off rate up to 25 l/min Z012 823
or
Vitotrans 353 freshwater module for cylinder mounting, type PZM with draw-off rate up to 48 l/min Z012 824
qQ Integral control unit Standard delivery pos. 10
qW DHW circulation pump Standard delivery pos. 10
qE Return distribution set as 3-way diverter valve Standard delivery pos. 10
rZ Temperature sensor for heating of the heating water buffer cylinder by the heat source Standard delivery pos. 2
5517 115 GB

VITOTRANS 353 VIESMANN 7


ID: 4611316_1404_01 (cont.)

Electrical installation scheme

11 Vitotrans 353

N
230V/50Hz
L
L'
N M
1~
ZP 12

L'
N

2 L
230V/50Hz

R1 N

L
R2 N 2
M
1 1~ RLV 13
L 3
R3 N

R4
Low voltage

9
S5 10

23
PWM2 24

ID: 4611316_1404_01

5517 115 GB

8 VIESMANN VITOTRANS 353


ID: 4611319_1404_01

3. DHW heating with Vitotrans 353 freshwater module, type PBS/PBM/PBL for wall mount-
ing and heating water buffer cylinder

The freshwater module provides DHW heating when hot water is


drawn or during DHW circulation. Control unit qQ controls the DHW
heating according to demand via combined DHW temperature and
flow control.
The DHW is heated in freshwater module qP according to the instan-
taneous water heater principle. An internal pump transfers the heating
water from heating water buffer cylinder 1 into freshwater modules
qP. The heat exchanger in freshwater module qP heats the DHW
according to the countercurrent principle.
In DHW systems with DHW circulation pump qW, the return manifold
ID: 4611319_1404_01 set can be used as 3-way diverter valve qE for optimised stratification
of the return water into heating water buffer cylinder 1.

Application Note
Detached/two-family houses with corresponding DHW demand This scheme is a general system example. Please refer to the
appropriate technical guides when planning specific applica- 3
Main components tions.
■ Vitotrans 353, type PBS/PBM/PBL
■ Heating water buffer cylinder

Function description

DHW heating
The freshwater module is supplied with energy by the heating water
buffer cylinder. This is heated by heat source 2.

ID: 4611319_1404_01
Vitotrans 353 master coding address
Assembly Code Function
DHW circulation "DHW circulation type/thermal/thermal + Activation of DHW circulation
demand"
DHW circulation/return "Return stratification: Yes" Function enabled
stratification
DHW circulation/return "Return stratification: Thermostat, differ- Differential: If cylinder temperature sensor S5 is installed in the heating
stratification ential" water buffer cylinder

Hydraulic installation scheme ID: 4611319_1404_01

WW

KW
A
C
M 13
B
--11/S5-- 14 10
--STS-- 46

1
--S5--

2 11
--L--
--R1--
--230V--
--R2--
5517 115 GB

Note: This scheme is a general example without shut-off valves or safety equipment. This does not replace the need for on-site engineering.

VITOTRANS 353 VIESMANN 9


ID: 4611319_1404_01 (cont.)

Equipment required

ID: 4611319_1404_01
Pos. Designation Part no.
Heating water supply
1 Heating water buffer cylinder See Viessmann pricelist
2 Connection to the heat source On site
DHW heating by freshwater module
qP Vitotrans 353 freshwater module for wall mounting, type PBS with draw-off rate up to 25 l/min Z012 820
qQ Integral control unit Standard delivery pos. 10
qP Vitotrans 353 freshwater module for wall mounting, type PBM with draw-off rate up to 48 l/min Z012 821
qQ Integral control unit Standard delivery pos. 10
qP Vitotrans 353 freshwater module for wall mounting, type PBL with draw-off rate up to 68 l/min Z012 822
qQ Integral control unit Standard delivery pos. 10
qE Return manifold set as 3-way diverter valve ZK01 343 / ZK01 344
qR Return temperature sensor for return stratification ZK01 345
rZ Temperature sensor for heating of the heating water buffer cylinder by the heat source Standard delivery pos. 2

Electrical installation scheme

3
11 Vitotrans 353

N
230V/50Hz
L
L'
N M
1~
ZP 12

L'
N

L
230V/50Hz

R1 N

L
R2 N 2
M
1 1~ RLV 13
L 3
R3 N

R4
Low voltage

9
S5 10 TSP 14
23
PWM2 24

ID: 4611319_1404_01
5517 115 GB

10 VIESMANN VITOTRANS 353


ID: 4611318_1404_01

4. DHW heating with Vitotrans 353 freshwater module, type PBS/PBM/PBL for wall mount-
ing and heating water buffer cylinder, with solar function

In DHW systems with DHW circulation pump qW, the return manifold
set can be used as 3-way diverter valve qE for optimised stratification
of the return water into heating water buffer cylinder 1.
The heating water buffer cylinder is additionally heated by the solar
thermal system.

DHW heating with solar energy


If the temperature differential between solar collector sensor 5 and
cylinder temperature sensor 6 exceeds the start temperature differ-
ential, solar circuit pump 8 starts and heating water buffer cylinder
ID: 4611318_1404_01 1 is heated.
Solar circuit pump 8 is deactivated according to the following crite-
ria:
Application ■ The stop temperature differential is undershot
Detached/two-family houses with corresponding DHW demand ■ The electronic temperature limit of the control unit is exceeded (max.
90 °C) 7
Main components ■ The temperature selected at high limit safety cut-out rQ (if installed)
■ Vitotrans 353, type PBS, PBM, PBL is reached
■ Heating water buffer cylinder If there is sufficient insolation, the entire heating water buffer cylinder
1 is heated by the solar thermal system.
Function description The upper part of heating water buffer cylinder 1 is only reheated by
boiler 2 if the actual water temperature falls below the set tempera-
DHW heating ture selected at the boiler control unit.
The freshwater module is supplied with energy by the heating water 4
buffer cylinder. This is heated by heat source 2. Note
The freshwater module provides DHW heating when hot water is This scheme is a general system example. Please refer to the
drawn or during DHW circulation. Control unit qQ controls the DHW appropriate technical guides when planning specific applica-
heating according to demand via combined DHW temperature and tions.
flow control.
The DHW is heated in freshwater module qP according to the instan-
taneous water heater principle. An internal pump transfers the heating
water from heating water buffer cylinder 1 into freshwater module
qP. The heat exchanger in freshwater module qP heats the DHW
according to the countercurrent principle.

ID: 4611318_1404_01
Vitotrans 353 master coding address
Assembly Code Function
DHW circulation "DHW circulation type/thermal/thermal + Activation of DHW circulation
demand"
DHW circulation/RT strat- "Return stratification: Yes" Function enabled
ifctn
DHW circulation/RT strat- "Return stratification: Thermostat, differ- Differential: If cylinder temperature sensor S5 is installed in the heating
ifctn ential" water buffer cylinder
5517 115 GB

VITOTRANS 353 VIESMANN 11


ID: 4611318_1404_01 (cont.)

Hydraulic installation scheme ID: 4611318_1404_01

--STS--
--145--
--4/KTS--

--KTS--
--230V--
7

WW

41
13 KW
A
4 C
M P2

P3

--11/S5-- 14 B 10
46
--3/STS-- 6
--S5--

1
11
--L--
--R1--
--230V--
--R2--

Note: This scheme is a general example without shut-off valves or safety equipment. This does not replace the need for on-site engineering.

Equipment required

ID: 4611318_1404_01
Pos. Designation Part no.
Heating water supply
1 Heating water buffer cylinder See Viessmann pricelist
2 Connection to the heat source On site
3 Solar control unit, type solar module SM1, Vitosolic 100 type SD1 or Vitosolic 200 type SD4 See Viessmann pricelist
4 Collectors See Viessmann pricelist
5 Solar collector sensor Standard delivery pos. 3
6 Cylinder temperature sensor STS Standard delivery pos. 3
7 Solar-Divicon, according to the application See Viessmann pricelist
8 Solar circulation pump Standard delivery pos. 7
DHW heating by freshwater module
qP Vitotrans 353 freshwater module for wall mounting, type PBS with draw-off rate up to 25 l/min Z012 820
or
Vitotrans 353 freshwater module for wall mounting, type PBM with draw-off rate up to 48 l/min Z012 821
or
Vitotrans 353 freshwater module for wall mounting, type PBL with draw-off rate up to 68 l/min Z012 822
qQ Integral control unit Standard delivery pos. 10
qE Return manifold set as 3-way diverter valve ZK01 353
qR Return temperature sensor for return stratification ZK01 345
rQ High limit safety cut-out sensor STB Z001 889
5517 115 GB

rZ Temperature sensor for heating of the heating water buffer cylinder by the heat source Standard delivery pos. 2

12 VIESMANN VITOTRANS 353


ID: 4611318_1404_01 (cont.)

Electrical installation scheme

11 Vitotrans 353

N
230V/50Hz
L
L'
N M
1~
ZP 12

L'
N

L
230V/50Hz

R1 N

L
R2 N 2
M
1 1~ RLV 13
L 3
R3 N

R4
Low voltage

9
S5 10 TSP 14
23
PWM2 24

4
ID: 4611318_1404_01
5517 115 GB

VITOTRANS 353 VIESMANN 13


ID: 4611314_1404_01

5. DHW heating in 2-module cascade, comprising Vitotrans 353 freshwater modules, type
PBM/PBL for wall mounting and heating water buffer cylinder, with solar function

DHW is heated in freshwater modules qP / wP according to the instan-


taneous water heater principle. An internal pump transfers the heating
water from heating water buffer cylinder 1 into freshwater modules
qP / wP. The heat exchangers in freshwater modules qP / wP heat the
DHW according to the countercurrent principle. Control is provided by
control unit qQ of freshwater module qP, defined as the master control
unit.
In DHW systems with DHW circulation pump qW, the return manifold
set can be used as 3-way diverter valve qE for optimised stratification
of the return water into heating water buffer cylinder 1. The heating
ID: 4611314_1404_01 water buffer cylinder is additionally heated by the solar thermal sys-
tem.

Application Heating water heating with solar energy


Residential, sports and industrial buildings with corresponding DHW If the temperature differential between solar collector sensor 5 and
demand, e.g. apartment buildings, hotels, sports facilities, care homes, cylinder temperature sensor 6 exceeds the start temperature differ-
etc. ential, solar circuit pump 8 starts and heating water buffer cylinder
1 is heated.
Main components Solar circuit pump 8 is deactivated according to the following crite-
■ Vitotrans 353, type PBM/PBL ria:
■ Return manifold set ■ The stop temperature differential is undershot
■ Heating water buffer cylinder ■ The electronic temperature limit of the control unit is exceeded (max.
■ Solar thermal system 90 °C) 7
■ The temperature selected at high limit safety cut-out rQ (if installed)
Function description is reached
If there is sufficient insolation, the entire heating water buffer cylinder
DHW heating 1 is heated by the solar thermal system.
The cascade of freshwater modules is supplied with energy by the The upper part of heating water buffer cylinder 1 is only reheated by
heating water buffer cylinder. This is heated by heat source 2 or by boiler 2 if the actual water temperature falls below the set tempera-
solar collectors 4. ture selected at the boiler control unit.
The cascade of freshwater modules provides DHW heating when hot
water is drawn or during DHW circulation. Master control unit qQ con-
5 trols the DHW heating according to demand via combined DHW tem- Note
perature and flow control. This scheme is a general system example. Please refer to the
Subject to demand, 1 or 2 freshwater modules can be connected in appropriate technical guides when planning specific applica-
parallel. tions.

ID: 4611314_1404_01
Vitotrans 353 master coding address
Assembly Code Function
Cascade "Control unit type/cascade master" Cascade master setting
DHW circulation "DHW circulation type/thermal/thermal + Activation of DHW circulation
demand"
DHW circulation "DHW circulation sensor/KS4/S6" DHW circulation pump control KS4, select from highest value of DHW
circulation sensors S4. S6 for optimised control of the DHW circulation
pump
DHW circulation/return "Return stratification: Yes" Function enabled
stratification
DHW circulation/return "Return stratification: Thermostat, differ- Differential: If cylinder temperature sensor S5 is installed in the heating
stratification ential" water buffer cylinder
Vitotrans 353 slave 1 coding address/wP
Cascade Control unit type/cascade slave 1 Setting 1
5517 115 GB

14 VIESMANN VITOTRANS 353


ID: 4611314_1404_01 (cont.)

Hydraulic installation scheme ID: 4611314_1404_01

--STS--

--KTS--
--3/KTS--

--145--
4

--230V--
--3/UPS--
7

8 --3/UPS--

WW

9 --11/L'/;WM2--
M 15 M 25 12
--11/R1--

--21/R1--
A 13
C
M
B 16
--11/S5-- 14

--11/S6--
--3/STS-- 6 10 20
46

KW
1 5
--V-BUS--

--V-BUS--
--PWM2--
--S5--
--S6--

2
11 21
--R1--
--230V--
--L--
--R1--
--230V--
--R2--

Note: This scheme is a general example without shut-off valves or safety equipment. This does not replace the need for on-site engineering.
5517 115 GB

VITOTRANS 353 VIESMANN 15


ID: 4611314_1404_01 (cont.)

Equipment required

ID: 4611314_1404_01
Pos. Designation Part no.
Heating water supply
1 Heating water buffer cylinder See Viessmann pricelist
2 Connection to the heat source On site
3 Solar control unit, type solar module SM1, Vitosolic 100 type SD1 or Vitosolic 200 type SD4 See Viessmann pricelist
4 Collectors See Viessmann pricelist
5 Solar collector sensor Standard delivery pos. 3
6 Cylinder temperature sensor STS (solar heating) Standard delivery pos. 3
7 Solar-Divicon, according to the application See Viessmann pricelist
8 Solar circulation pump Standard delivery pos. 7
9 High limit safety cut-out STB Z001 889
DHW heating by the cascade
qP Vitotrans 353 freshwater module for wall mounting, type PBM with draw-off rate up to 48 l/min Z012 821
qQ Integral control unit (master) Standard delivery pos. 10
qT Diverter valve cascade PBM (2-way valve) ZK01 347
or
qP Vitotrans 353 freshwater module for wall mounting, type PBL with draw-off rate up to 68 l/min Z012 822
Standard delivery pos. 10
qT Diverter valve cascade PBL (2-way valve) ZK01 348
qW DHW circulation pump ZK01 349 / ZK01 350
qE Return manifold set as 3-way diverter valve ZK01 353
ZK01 345
qZ Return temperature sensor for optimised DHW circulation ZK01 352
wP Vitotrans 353 freshwater module for wall mounting, type PBM with draw-off rate up to 48 l/min Z012 821
wQ Integral control unit (slave 1) Standard delivery pos. 20
wT Diverter valve cascade PBM (2-way valve) ZK01 347
or
wP Vitotrans 353 freshwater module for wall mounting, type PBL with draw-off rate up to 68 l/min Z012 822
wQ Integral control unit (slave 1) Standard delivery pos. 20
wT Diverter valve cascade PBL (2-way valve) ZK01 348
rZ Temperature sensor for heating of the heating water buffer cylinder by the heat source Standard delivery pos. 2

Electrical installation scheme

5
11 Master 21 Slave 1

N N
230V/50Hz 230V/50Hz
L L
L' L'
N M
1~
ZP 12 N

L' L'
N N
230V/50Hz

L L
230V/50Hz

M M MV 25
R1 N 1~ MV 15 R1 N 1~

L L
R2 N 2 R2 N
M
1 1~ RLV 13
L 3 L
R3 N R3 N

R4 R4

9 9
S5 10 TSP 14 S5 10
Low voltage

Low voltage

9 9
S6 10 ZLS 16 S6 10

23 23
PWM2 24
PWM2 24

23 23
V BUS 24
V BUS 24
5517 115 GB

ID: 4611314_1404_01

16 VIESMANN VITOTRANS 353


ID: 4611312_1404_01

6. DHW heating in 4-module cascade, comprising Vitotrans 353 freshwater modules, type
PBM/PBL for wall mounting and heating water buffer cylinder

The cascade of freshwater modules provides DHW heating when hot


water is drawn or during DHW circulation. Master control unit qQ con-
trols the DHW heating according to demand via combined DHW tem-
perature and flow control.
Subject to demand, 1 to 4 freshwater modules can be connected in
parallel.
DHW is heated in freshwater modules qP / wP / eP / rP according to
the instantaneous water heater principle. An internal pump transfers
the heating water from heating water buffer cylinder 1 into freshwater
modules qP / wP / eP / rP. The heat exchangers in freshwater modules
ID: 4611312_1404_01 qP / wP / eP / rP heat the DHW according to the countercurrent prin-
ciple. Control is provided by control unit qQ of freshwater module qP,
defined as the master control unit.
Application In DHW systems with DHW circulation pump qW, the return manifold
Residential, sports and industrial buildings with corresponding DHW set can be used as 3-way diverter valve qE for optimised stratification
demand, e.g. apartment buildings, hotels, sports facilities, care homes, of the return water into heating water buffer cylinder 1.
etc.

Main components Note


■ Vitotrans 353, type PBM/PBL This scheme is a general system example. Please refer to the
■ Return manifold set appropriate technical guides when planning specific applica-
■ Heating water buffer cylinder tions.

Function description

DHW heating
The cascade of freshwater modules is supplied with energy by the
heating water buffer cylinder. This is heated by heat source 2.

ID: 4611312_1404_01
Vitotrans 353 master coding address
Assembly Code Function
Cascade "Control unit type/cascade master" Cascade master setting
DHW circulation "DHW circulation type/thermal/thermal + Activation of DHW circulation
demand"
DHW circulation "DHW circulation sensor/KS4/S6" DHW circulation pump control KS4, select from highest value of DHW
circulation sensors S4. S6 for optimised control of the DHW circulation
pump
DHW circulation/return "Return stratification: Yes" Function enabled
stratification
DHW circulation/return "Return stratification: Thermostat, differ- Differential: If cylinder temperature sensor S5 is installed in the heating 6
stratification ential" water buffer cylinder
Vitotrans 353 slave 1 coding address/wP
Cascade Control unit type/cascade slave 1 Setting 1
Vitotrans 353 slave 2 coding address/eP
Cascade Control unit type/cascade slave 2 Setting 2
Vitotrans 353 slave 3 coding address/rP
Cascade Control unit type/cascade slave 3 Setting 3
5517 115 GB

VITOTRANS 353 VIESMANN 17


ID: 4611312_1404_01 (cont.)

Hydraulic installation scheme ID: 4611312_1404_01

--11/L'/;WM2--
WW

KW
16
12
--11/S6--

45
--41/R1--

M
--230V--

40

41
--V-BUS--
--R1--

35

--31/R1--
M

30 --230V--

31
--V-BUS--
--R1--
25

--21/R1--
M

--230V--
20

21
--V-BUS--
--R1--
15

--11/R1--
M

--V-BUS-- --R2--
--PWM2-- --230V--
10

11

--S6-- --R1--
--S5-- --L--
--11/S5-- 14
--STS--
M 13

46
B
A

6
C

1
1
1

Note: This scheme is a general example without shut-off valves or safety equipment. This does not replace the need for on-site engineering.
5517 115 GB

18 VIESMANN VITOTRANS 353


ID: 4611312_1404_01 (cont.)

Equipment required

ID: 4611312_1404_01
Pos. Designation Part no.
Heating water supply
1 Heating water buffer cylinder See Viessmann pricelist
2 Connection to the heat source On site
DHW heating by the cascade
qP Vitotrans 353 freshwater module for wall mounting, type PBM with draw-off rate up to 48 l/min Z012 821
qQ Integral control unit (master) Standard delivery pos. 10
qT Diverter valve cascade PBM (2-way valve) ZK01 347
or
qP Vitotrans 353 freshwater module for wall mounting, type PBL with draw-off rate up to 68 l/min Z012 822
qQ Integral control unit (master) Standard delivery pos. 10
qT Diverter valve cascade PBL (2-way valve) ZK01 348
qW DHW circulation pump ZK01 349 / ZK01 350
qE Return manifold set as 3-way diverter valve ZK01 353
qR Return temperature sensor for return stratification ZK01 345
qZ Return temperature sensor for optimised DHW circulation ZK01 352
wP Vitotrans 353 freshwater module for wall mounting, type PBM with draw-off rate up to 48 l/min Z012 821
wQ Integral control unit (slave 1) Standard delivery pos. 20
wT Diverter valve cascade PBM (2-way valve) ZK01 347
or
wP Vitotrans 353 freshwater module for wall mounting, type PBL with draw-off rate up to 68 l/min Z012 822
wQ Integral control unit (slave 1) Standard delivery pos. 20
wT Diverter valve cascade PBL (2-way valve) ZK01 348
eP Vitotrans 353 freshwater module for wall mounting, type PBM with draw-off rate up to 48 l/min Z012 821
eQ Integral control unit (slave 2) Standard delivery pos. 30
eT Diverter valve cascade PBM (2-way valve) ZK01 347
or
eP Vitotrans 353 freshwater module for wall mounting, type PBL with draw-off rate up to 68 l/min Z012 822
eQ Integral control unit (slave 2) Standard delivery pos. 30
eT Diverter valve cascade PBL (2-way valve) ZK01 348
rP Vitotrans 353 freshwater module for wall mounting, type PBM with draw-off rate up to 48 l/min Z012 821
rQ Integral control unit (slave 3) Standard delivery pos. 40
rT Diverter valve cascade PBM (2-way valve) ZK01 347
or
rP Vitotrans 353 freshwater module for wall mounting, type PBL with draw-off rate up to 68 l/min Z012 822
rQ Integral control unit (slave 3) Standard delivery pos. 40
rT Diverter valve cascade PBL (2-way valve) ZK01 348
rZ Temperature sensor for heating of the heating water buffer cylinder by the heat source Standard delivery pos. 2

6
5517 115 GB

VITOTRANS 353 VIESMANN 19


ID: 4611312_1404_01 (cont.)

Electrical installation scheme

11 Master 41 Slave 3

N N
230V/50Hz 230V/50Hz
L L
L' L'
N M
1~
ZP 12 N

L' L'
N N

230V/50Hz
L L
230V/50Hz

R1 N M MV 15 R1 N M
MV
1~ 1~ 45

L L
R2 N 2 R2 N
M
1 1~ RLV 13
L 3 L
R3 N R3 N

R4 R4

9 9
S5 10 TSP 14 S5 10
Low voltage

Low voltage

9 9
S6 10 ZLS 16 S6 10

23 23
PWM2 24
PWM2 24

23 23
V BUS 24
V BUS 24

21 Slave 1 31 Slave 2

N N
230V/50Hz 230V/50Hz
L L
L' L'
N N

L' L'
N N
230V/50Hz

230V/50Hz

L L
M M MV 35
R1 N 1~ MV 25 R1 N 1~

L L
R2 N R2 N

6 L L
R3 N R3 N

R4 R4

9 9
S5 10
S5 10
Low voltage
Low voltage

9 9
S6 10
S6 10

23 23
PWM2 24
PWM2 24

23 23
V BUS 24
V BUS 24

ID: 4611312_1404_01
5517 115 GB

20 VIESMANN VITOTRANS 353


5517 115 GB

VITOTRANS 353 VIESMANN 21


22 VIESMANN VITOTRANS 353
5517 115 GB

VITOTRANS 353 VIESMANN 23


Subject to technical modifications.

Viessmann Werke GmbH&Co KG Viessmann Limited


D-35107 Allendorf Hortonwood 30, Telford
5517 115 GB

Telephone: +49 6452 70-0 Shropshire, TF1 7YP, GB


Fax: +49 6452 70-2780 Telephone: +44 1952 675000
www.viessmann.com Fax: +44 1952 675040
E-mail: info-uk@viessmann.com