System examples
Index
1.
DHW heating with Vitotrans 353 freshwater module, type PZS/PZM for
cylinder mounting and heating water buffer cylinder ................................. 4
ID: 4611317_1404_01
2.
DHW heating with Vitotrans 353 freshwater module, type PZS/PZM for
cylinder mounting, heating water buffer cylinder and solar function .......... 6
ID: 4611316_1404_01
3.
DHW heating with Vitotrans 353 freshwater module, type PBS/PBM/PBL
for wall mounting and heating water buffer cylinder .................................. 9
ID: 4611319_1404_01
4.
DHW heating with Vitotrans 353 freshwater module, type PBS/PBM/PBL
for wall mounting and heating water buffer cylinder, with solar function . . . 11
ID: 4611318_1404_01
5.
DHW heating in 2-module cascade, comprising Vitotrans 353 freshwater
modules, type PBM/PBL for wall mounting and heating water buffer cylin-
der, with solar function ............................................................................... 14
ID: 4611314_1404_01
6.
DHW heating in 4-module cascade, comprising Vitotrans 353 freshwater
modules, type PBM/PBL for wall mounting and heating water buffer cylin-
der ............................................................................................................. 17
ID: 4611312_1404_01
5517 115 GB
qR
--11/S5--
--11/S5-- qR
qQ
--S5--
9
[G
S
10
qQ
--L--
--R1--
--230V--
--R2--
5517 115 GB
1. DHW heating with Vitotrans 353 freshwater module, type PZS/PZM for cylinder mount-
ing and heating water buffer cylinder
1
The freshwater module provides DHW heating when hot water is
drawn or during DHW circulation. Control unit qQ controls the DHW
heating according to demand via combined DHW temperature and
flow control.
The DHW is heated in freshwater module qP according to the instan-
taneous water heater principle. An internal pump transfers the heating
water from heating water buffer cylinder 1 into freshwater module
qP. The heat exchanger in freshwater module qP heats the DHW
according to the countercurrent principle.
In freshwater modules for cylinder mounting, the DHW circulation
ID: 4611317_1404_01 pump and the return distribution set are installed at the factory.
Note
Application This scheme is a general system example. Please refer to the
Detached/two-family houses with corresponding DHW demand appropriate technical guides when planning specific applica-
tions.
Main components
■ Vitotrans 353, type PZS, PZM
■ Heating water buffer cylinder
Function description
DHW heating
The freshwater module is supplied with energy by the heating water
buffer cylinder. This is heated by heat source 2.
ID: 4611317_1404_01
Vitotrans 353 coding address
Assembly Code Function
DHW circulation "DHW circulation type/thermal/thermal + Activation of DHW circulation
demand"
WW
--3/STS--
6
KW 11
--L--
--R2--
--230V--
46
10 2
Note: This scheme is a general example without shut-off valves or safety equipment. This does not replace the need for on-site engineering.
5517 115 GB
Equipment required
ID: 4611317_1404_01
Pos. Designation Part no.
1
Heating water supply
1 Heating water buffer cylinder See Viessmann pricelist
2 Connection to the heat source On site
DHW heating by freshwater module
qP Vitotrans 353 freshwater module for cylinder mounting, type PZS with draw-off rate up to 25 l/min Z012 823
or
Vitotrans 353 freshwater module for cylinder mounting, type PZM with draw-off rate up to 48 l/min Z012 824
qQ Integral control unit Standard delivery pos. 10
rZ Temperature sensor for heating of the heating water buffer cylinder by the heat source Standard delivery pos. 2
11 Vitotrans 353
N
230V/50Hz
L
L'
N M
1~
ZP 12
L'
N
L
230V/50Hz
R1 N
L
R2 N
L
R3 N
R4
Low voltage
9
S5 10
23
PWM2 24
ID: 4611317_1404_01
5517 115 GB
2. DHW heating with Vitotrans 353 freshwater module, type PZS/PZM for cylinder mount-
ing, heating water buffer cylinder and solar function
ID: 4611316_1404_01
Vitotrans 353 coding address
Assembly Code Function
DHW circulation "DHW circulation type/thermal/thermal + Activation of DHW circulation
demand"
5517 115 GB
--3/KTS-- 4
2
WW
7
9
--STS--
--KTS--
--145--
3
--UPS--
--230V--
1 46
--3/STS--
6
KW 11
--L--
--R2--
--230V--
10 2
Note: This scheme is a general example without shut-off valves or safety equipment. This does not replace the need for on-site engineering.
Equipment required
ID: 4611316_1404_01
Pos. Designation Part no.
Heating water supply
1 Heating water buffer cylinder See Viessmann pricelist
2 Connection to the heat source On site
3 Solar control unit, type solar module SM1, Vitosolic 100 type SD1 or Vitosolic 200 type SD4 See Viessmann pricelist
4 Collectors See Viessmann pricelist
5 Solar collector sensor Standard delivery pos. 3
6 Cylinder temperature sensor STS (solar) Standard delivery pos. 3
7 Solar-Divicon, for installation on the cylinder See Viessmann pricelist
8 Solar circulation pump Standard delivery pos. 7
9 High limit safety cut-out STB Z001 889
DHW heating by freshwater module
qP Vitotrans 353 freshwater module for cylinder mounting, type PZS with draw-off rate up to 25 l/min Z012 823
or
Vitotrans 353 freshwater module for cylinder mounting, type PZM with draw-off rate up to 48 l/min Z012 824
qQ Integral control unit Standard delivery pos. 10
qW DHW circulation pump Standard delivery pos. 10
qE Return distribution set as 3-way diverter valve Standard delivery pos. 10
rZ Temperature sensor for heating of the heating water buffer cylinder by the heat source Standard delivery pos. 2
5517 115 GB
11 Vitotrans 353
N
230V/50Hz
L
L'
N M
1~
ZP 12
L'
N
2 L
230V/50Hz
R1 N
L
R2 N 2
M
1 1~ RLV 13
L 3
R3 N
R4
Low voltage
9
S5 10
23
PWM2 24
ID: 4611316_1404_01
5517 115 GB
3. DHW heating with Vitotrans 353 freshwater module, type PBS/PBM/PBL for wall mount-
ing and heating water buffer cylinder
Application Note
Detached/two-family houses with corresponding DHW demand This scheme is a general system example. Please refer to the
appropriate technical guides when planning specific applica- 3
Main components tions.
■ Vitotrans 353, type PBS/PBM/PBL
■ Heating water buffer cylinder
Function description
DHW heating
The freshwater module is supplied with energy by the heating water
buffer cylinder. This is heated by heat source 2.
ID: 4611319_1404_01
Vitotrans 353 master coding address
Assembly Code Function
DHW circulation "DHW circulation type/thermal/thermal + Activation of DHW circulation
demand"
DHW circulation/return "Return stratification: Yes" Function enabled
stratification
DHW circulation/return "Return stratification: Thermostat, differ- Differential: If cylinder temperature sensor S5 is installed in the heating
stratification ential" water buffer cylinder
WW
KW
A
C
M 13
B
--11/S5-- 14 10
--STS-- 46
1
--S5--
2 11
--L--
--R1--
--230V--
--R2--
5517 115 GB
Note: This scheme is a general example without shut-off valves or safety equipment. This does not replace the need for on-site engineering.
Equipment required
ID: 4611319_1404_01
Pos. Designation Part no.
Heating water supply
1 Heating water buffer cylinder See Viessmann pricelist
2 Connection to the heat source On site
DHW heating by freshwater module
qP Vitotrans 353 freshwater module for wall mounting, type PBS with draw-off rate up to 25 l/min Z012 820
qQ Integral control unit Standard delivery pos. 10
qP Vitotrans 353 freshwater module for wall mounting, type PBM with draw-off rate up to 48 l/min Z012 821
qQ Integral control unit Standard delivery pos. 10
qP Vitotrans 353 freshwater module for wall mounting, type PBL with draw-off rate up to 68 l/min Z012 822
qQ Integral control unit Standard delivery pos. 10
qE Return manifold set as 3-way diverter valve ZK01 343 / ZK01 344
qR Return temperature sensor for return stratification ZK01 345
rZ Temperature sensor for heating of the heating water buffer cylinder by the heat source Standard delivery pos. 2
3
11 Vitotrans 353
N
230V/50Hz
L
L'
N M
1~
ZP 12
L'
N
L
230V/50Hz
R1 N
L
R2 N 2
M
1 1~ RLV 13
L 3
R3 N
R4
Low voltage
9
S5 10 TSP 14
23
PWM2 24
ID: 4611319_1404_01
5517 115 GB
4. DHW heating with Vitotrans 353 freshwater module, type PBS/PBM/PBL for wall mount-
ing and heating water buffer cylinder, with solar function
In DHW systems with DHW circulation pump qW, the return manifold
set can be used as 3-way diverter valve qE for optimised stratification
of the return water into heating water buffer cylinder 1.
The heating water buffer cylinder is additionally heated by the solar
thermal system.
ID: 4611318_1404_01
Vitotrans 353 master coding address
Assembly Code Function
DHW circulation "DHW circulation type/thermal/thermal + Activation of DHW circulation
demand"
DHW circulation/RT strat- "Return stratification: Yes" Function enabled
ifctn
DHW circulation/RT strat- "Return stratification: Thermostat, differ- Differential: If cylinder temperature sensor S5 is installed in the heating
ifctn ential" water buffer cylinder
5517 115 GB
--STS--
--145--
--4/KTS--
--KTS--
--230V--
7
WW
41
13 KW
A
4 C
M P2
P3
--11/S5-- 14 B 10
46
--3/STS-- 6
--S5--
1
11
--L--
--R1--
--230V--
--R2--
Note: This scheme is a general example without shut-off valves or safety equipment. This does not replace the need for on-site engineering.
Equipment required
ID: 4611318_1404_01
Pos. Designation Part no.
Heating water supply
1 Heating water buffer cylinder See Viessmann pricelist
2 Connection to the heat source On site
3 Solar control unit, type solar module SM1, Vitosolic 100 type SD1 or Vitosolic 200 type SD4 See Viessmann pricelist
4 Collectors See Viessmann pricelist
5 Solar collector sensor Standard delivery pos. 3
6 Cylinder temperature sensor STS Standard delivery pos. 3
7 Solar-Divicon, according to the application See Viessmann pricelist
8 Solar circulation pump Standard delivery pos. 7
DHW heating by freshwater module
qP Vitotrans 353 freshwater module for wall mounting, type PBS with draw-off rate up to 25 l/min Z012 820
or
Vitotrans 353 freshwater module for wall mounting, type PBM with draw-off rate up to 48 l/min Z012 821
or
Vitotrans 353 freshwater module for wall mounting, type PBL with draw-off rate up to 68 l/min Z012 822
qQ Integral control unit Standard delivery pos. 10
qE Return manifold set as 3-way diverter valve ZK01 353
qR Return temperature sensor for return stratification ZK01 345
rQ High limit safety cut-out sensor STB Z001 889
5517 115 GB
rZ Temperature sensor for heating of the heating water buffer cylinder by the heat source Standard delivery pos. 2
11 Vitotrans 353
N
230V/50Hz
L
L'
N M
1~
ZP 12
L'
N
L
230V/50Hz
R1 N
L
R2 N 2
M
1 1~ RLV 13
L 3
R3 N
R4
Low voltage
9
S5 10 TSP 14
23
PWM2 24
4
ID: 4611318_1404_01
5517 115 GB
5. DHW heating in 2-module cascade, comprising Vitotrans 353 freshwater modules, type
PBM/PBL for wall mounting and heating water buffer cylinder, with solar function
ID: 4611314_1404_01
Vitotrans 353 master coding address
Assembly Code Function
Cascade "Control unit type/cascade master" Cascade master setting
DHW circulation "DHW circulation type/thermal/thermal + Activation of DHW circulation
demand"
DHW circulation "DHW circulation sensor/KS4/S6" DHW circulation pump control KS4, select from highest value of DHW
circulation sensors S4. S6 for optimised control of the DHW circulation
pump
DHW circulation/return "Return stratification: Yes" Function enabled
stratification
DHW circulation/return "Return stratification: Thermostat, differ- Differential: If cylinder temperature sensor S5 is installed in the heating
stratification ential" water buffer cylinder
Vitotrans 353 slave 1 coding address/wP
Cascade Control unit type/cascade slave 1 Setting 1
5517 115 GB
--STS--
--KTS--
--3/KTS--
--145--
4
--230V--
--3/UPS--
7
8 --3/UPS--
WW
9 --11/L'/;WM2--
M 15 M 25 12
--11/R1--
--21/R1--
A 13
C
M
B 16
--11/S5-- 14
--11/S6--
--3/STS-- 6 10 20
46
KW
1 5
--V-BUS--
--V-BUS--
--PWM2--
--S5--
--S6--
2
11 21
--R1--
--230V--
--L--
--R1--
--230V--
--R2--
Note: This scheme is a general example without shut-off valves or safety equipment. This does not replace the need for on-site engineering.
5517 115 GB
Equipment required
ID: 4611314_1404_01
Pos. Designation Part no.
Heating water supply
1 Heating water buffer cylinder See Viessmann pricelist
2 Connection to the heat source On site
3 Solar control unit, type solar module SM1, Vitosolic 100 type SD1 or Vitosolic 200 type SD4 See Viessmann pricelist
4 Collectors See Viessmann pricelist
5 Solar collector sensor Standard delivery pos. 3
6 Cylinder temperature sensor STS (solar heating) Standard delivery pos. 3
7 Solar-Divicon, according to the application See Viessmann pricelist
8 Solar circulation pump Standard delivery pos. 7
9 High limit safety cut-out STB Z001 889
DHW heating by the cascade
qP Vitotrans 353 freshwater module for wall mounting, type PBM with draw-off rate up to 48 l/min Z012 821
qQ Integral control unit (master) Standard delivery pos. 10
qT Diverter valve cascade PBM (2-way valve) ZK01 347
or
qP Vitotrans 353 freshwater module for wall mounting, type PBL with draw-off rate up to 68 l/min Z012 822
Standard delivery pos. 10
qT Diverter valve cascade PBL (2-way valve) ZK01 348
qW DHW circulation pump ZK01 349 / ZK01 350
qE Return manifold set as 3-way diverter valve ZK01 353
ZK01 345
qZ Return temperature sensor for optimised DHW circulation ZK01 352
wP Vitotrans 353 freshwater module for wall mounting, type PBM with draw-off rate up to 48 l/min Z012 821
wQ Integral control unit (slave 1) Standard delivery pos. 20
wT Diverter valve cascade PBM (2-way valve) ZK01 347
or
wP Vitotrans 353 freshwater module for wall mounting, type PBL with draw-off rate up to 68 l/min Z012 822
wQ Integral control unit (slave 1) Standard delivery pos. 20
wT Diverter valve cascade PBL (2-way valve) ZK01 348
rZ Temperature sensor for heating of the heating water buffer cylinder by the heat source Standard delivery pos. 2
5
11 Master 21 Slave 1
N N
230V/50Hz 230V/50Hz
L L
L' L'
N M
1~
ZP 12 N
L' L'
N N
230V/50Hz
L L
230V/50Hz
M M MV 25
R1 N 1~ MV 15 R1 N 1~
L L
R2 N 2 R2 N
M
1 1~ RLV 13
L 3 L
R3 N R3 N
R4 R4
9 9
S5 10 TSP 14 S5 10
Low voltage
Low voltage
9 9
S6 10 ZLS 16 S6 10
23 23
PWM2 24
PWM2 24
23 23
V BUS 24
V BUS 24
5517 115 GB
ID: 4611314_1404_01
6. DHW heating in 4-module cascade, comprising Vitotrans 353 freshwater modules, type
PBM/PBL for wall mounting and heating water buffer cylinder
Function description
DHW heating
The cascade of freshwater modules is supplied with energy by the
heating water buffer cylinder. This is heated by heat source 2.
ID: 4611312_1404_01
Vitotrans 353 master coding address
Assembly Code Function
Cascade "Control unit type/cascade master" Cascade master setting
DHW circulation "DHW circulation type/thermal/thermal + Activation of DHW circulation
demand"
DHW circulation "DHW circulation sensor/KS4/S6" DHW circulation pump control KS4, select from highest value of DHW
circulation sensors S4. S6 for optimised control of the DHW circulation
pump
DHW circulation/return "Return stratification: Yes" Function enabled
stratification
DHW circulation/return "Return stratification: Thermostat, differ- Differential: If cylinder temperature sensor S5 is installed in the heating 6
stratification ential" water buffer cylinder
Vitotrans 353 slave 1 coding address/wP
Cascade Control unit type/cascade slave 1 Setting 1
Vitotrans 353 slave 2 coding address/eP
Cascade Control unit type/cascade slave 2 Setting 2
Vitotrans 353 slave 3 coding address/rP
Cascade Control unit type/cascade slave 3 Setting 3
5517 115 GB
--11/L'/;WM2--
WW
KW
16
12
--11/S6--
45
--41/R1--
M
--230V--
40
41
--V-BUS--
--R1--
35
--31/R1--
M
30 --230V--
31
--V-BUS--
--R1--
25
--21/R1--
M
--230V--
20
21
--V-BUS--
--R1--
15
--11/R1--
M
--V-BUS-- --R2--
--PWM2-- --230V--
10
11
--S6-- --R1--
--S5-- --L--
--11/S5-- 14
--STS--
M 13
46
B
A
6
C
1
1
1
Note: This scheme is a general example without shut-off valves or safety equipment. This does not replace the need for on-site engineering.
5517 115 GB
Equipment required
ID: 4611312_1404_01
Pos. Designation Part no.
Heating water supply
1 Heating water buffer cylinder See Viessmann pricelist
2 Connection to the heat source On site
DHW heating by the cascade
qP Vitotrans 353 freshwater module for wall mounting, type PBM with draw-off rate up to 48 l/min Z012 821
qQ Integral control unit (master) Standard delivery pos. 10
qT Diverter valve cascade PBM (2-way valve) ZK01 347
or
qP Vitotrans 353 freshwater module for wall mounting, type PBL with draw-off rate up to 68 l/min Z012 822
qQ Integral control unit (master) Standard delivery pos. 10
qT Diverter valve cascade PBL (2-way valve) ZK01 348
qW DHW circulation pump ZK01 349 / ZK01 350
qE Return manifold set as 3-way diverter valve ZK01 353
qR Return temperature sensor for return stratification ZK01 345
qZ Return temperature sensor for optimised DHW circulation ZK01 352
wP Vitotrans 353 freshwater module for wall mounting, type PBM with draw-off rate up to 48 l/min Z012 821
wQ Integral control unit (slave 1) Standard delivery pos. 20
wT Diverter valve cascade PBM (2-way valve) ZK01 347
or
wP Vitotrans 353 freshwater module for wall mounting, type PBL with draw-off rate up to 68 l/min Z012 822
wQ Integral control unit (slave 1) Standard delivery pos. 20
wT Diverter valve cascade PBL (2-way valve) ZK01 348
eP Vitotrans 353 freshwater module for wall mounting, type PBM with draw-off rate up to 48 l/min Z012 821
eQ Integral control unit (slave 2) Standard delivery pos. 30
eT Diverter valve cascade PBM (2-way valve) ZK01 347
or
eP Vitotrans 353 freshwater module for wall mounting, type PBL with draw-off rate up to 68 l/min Z012 822
eQ Integral control unit (slave 2) Standard delivery pos. 30
eT Diverter valve cascade PBL (2-way valve) ZK01 348
rP Vitotrans 353 freshwater module for wall mounting, type PBM with draw-off rate up to 48 l/min Z012 821
rQ Integral control unit (slave 3) Standard delivery pos. 40
rT Diverter valve cascade PBM (2-way valve) ZK01 347
or
rP Vitotrans 353 freshwater module for wall mounting, type PBL with draw-off rate up to 68 l/min Z012 822
rQ Integral control unit (slave 3) Standard delivery pos. 40
rT Diverter valve cascade PBL (2-way valve) ZK01 348
rZ Temperature sensor for heating of the heating water buffer cylinder by the heat source Standard delivery pos. 2
6
5517 115 GB
11 Master 41 Slave 3
N N
230V/50Hz 230V/50Hz
L L
L' L'
N M
1~
ZP 12 N
L' L'
N N
230V/50Hz
L L
230V/50Hz
R1 N M MV 15 R1 N M
MV
1~ 1~ 45
L L
R2 N 2 R2 N
M
1 1~ RLV 13
L 3 L
R3 N R3 N
R4 R4
9 9
S5 10 TSP 14 S5 10
Low voltage
Low voltage
9 9
S6 10 ZLS 16 S6 10
23 23
PWM2 24
PWM2 24
23 23
V BUS 24
V BUS 24
21 Slave 1 31 Slave 2
N N
230V/50Hz 230V/50Hz
L L
L' L'
N N
L' L'
N N
230V/50Hz
230V/50Hz
L L
M M MV 35
R1 N 1~ MV 25 R1 N 1~
L L
R2 N R2 N
6 L L
R3 N R3 N
R4 R4
9 9
S5 10
S5 10
Low voltage
Low voltage
9 9
S6 10
S6 10
23 23
PWM2 24
PWM2 24
23 23
V BUS 24
V BUS 24
ID: 4611312_1404_01
5517 115 GB