Professional Documents
Culture Documents
Catalogue
Valves
Series 300
Product Catalogue
Edition 09/2018
Series 300 Valves
Series 300 Valves Dorot’s Areas Of
Dorot, part of Matholding Group since 2014, is one of
the world’s leading manufacturers and developers
of sustainable technologies and products for
water control and optimization systems.
With more than 70 years of experience,
the company is a worldwide pioneer
in providing high quality solutions for
Hydraulic Controlled Valves and Air
Valves.
Edition 09/2018
Contents Series 300 Valves
General Information 4
Overview 4
Features 4
Engineering Data 5
Technical Specifications 5
Materials 5
Basic Valve Operating Modes 6
Typical Pressure Reducing Performance Chart 10
Cavitation Data 11
Dimensions & Weights 12
Size Selection Tables 14
Headloss Charts 15
Components 16
Waterworks Control Application 17
Electronic and Remote control functions 17
EL Solenoid Control Valve 17
EL\TO Two Stage Opening Solenoid Control Valve 18
EC Electronic Control Valve 19
Pressure Regulating functions 20
PR Pressure-Reducing Valve 20
PR[D] Proportional Pressure-Reducing Valve 21
PRM Dual Set-Point Pressure-Reducing Valve 22
HyMod Flow-Modulated Pressure-Reducing Valve 23
PS[R] Pressure-Sustaining\Relief Valve 24
PS Pressure-Sustaining Valve 25
PR\PS Pressure Sustaining\Reducing Valve 26
DI Pressure Differential Sustaining Valve 27
Rate of Flow Regulating functions 28
FR Flow Control Valve 28
FR\EL Flow Control Valve 29
Water Level Control functions 30
FL Modulating Float Valve 30
FLEL Electric Float Controlled Valve 31
FLDI Differential Float Valve 32
FLDI\PS Differential Float and Pressure Sustaining Valve 33
FLDI\FR(PR) Differential Float and Flow Control Valve 34
FLDI\SP Differential-Level Control Valve with Surge-Preventing closure 35
AL 3W Altitude Pilot Controlled Valve 36
CXAL 2W Altitude Pilot Controlled Valve 37
Pump Control functions 38
BC Pump Control Valve 39
BC\PS Pump Control and Pressure Sustaining Valve 39
NS Two-Stages, Cushioned Closure Check Valve 40
CV Hydraulic Non-Return Valve 41
DW Deep Well (Borehole) Pump Control Valve 42
Safety functions 43
RE Surge Anticipating Valve 43
REEL Surge Anticipating Valve 44
QR Quick Pressure-Relief Valve 45
FE Excessive Flow Shut-off Valve 46
Fire Protection Applications 47
Edition 09/2018
Series 300 Valves General Information
Overview
DOROT’S 300 Series, state-of-the-art automatic control valves are designed to withstand the most
demanding requirements of water system control. The experts at DOROT developed this technically-
advanced valve with capabilities- far beyond any other on the market.
This Engineering Data guide will asist the reader in the selection of the optimal DOROT Series 300
valve.
Features
Position indicator (optional) Air release nut
Diaphragm discs
Edition 09/2018
Engineering Data Series 300 Valves
Technical Specifications
Parameter Standard Optional
Connections
• Flanged ISO 7005 or ANSI B16 • Flanged AS10, JIS B22, ABNT and
• Threaded BSP or NPT others
Materials
Part Standard Optional
Note: The Dorot S-300 valves in all sizes, meet the USA amendment for reducing lead in drinking water marked
as S.3874 dated 01.05.2010.
Edition 09/2018
Series 300 Valves Engineering Data
Control
Open Mode Device
Control
Device
Opened Mode
Open Mode
Edition 09/2018
C M Y CM MY CY CMY K
Closed Valve
Fully Open
FullyOpen
Fully Open
Fully Open
Cavitation energy
dissipation area
Fully-opened
Regulating
Regulating Valve
Regulating
Regulating
Edition 09/2018
Series 300 Valves Engineering Data
2-Way Control Device Regulating Mode: The pilot is set to the required
downstream pressure. The pilot senses when the
The 2-way control device is assembled on a control downstream pressure reaches the required value
circuit, connecting upstream to downstream through causing passage (b) to equal passage (a) b=a. Now,
the control chamber. water that flows through the control loop passes
There are two restrictors assembled in this circuit: from (a) through (b) and into the downstream.
(a) A nozzle or a needle valve, at a fixed opening. The control media in the upper part of the control
(b) A modulating device (pilot), whose passage may chamber is now steady, keeping the diaphragm
vary from complete closure (b=o) to a fully open size and seal in a fixed position. Any change in the
(when b>a). downstream pressure will change the b=a balance.
The volume of the control media in the chamber is This change adds or drains water from the control
determined by the relative passages (a) and (b), or, chamber, thus opening or closing the main valve
in fact, by the opening of (b), as (a) is fixed. until it reaches the balanced regulating position b=a
once again.
Closed Mode: Pilot (b) senses a downstream
pressure higher than the set-point and closes
passage (b). Through passage (a) the upstream
water flows directly into the upper part of the control
chamber, forcing the diaphragm to close the valve.
Regulating Valve
Regulating Valve
Open Mode
Opened Valve
Open Mode
Edition 09/2018
.G3-d 3/3/02 11:50 Page 1
C M Y CM MY CY CMY K
3-WayControl
3-Way Control Device
Device Proportional Pressure
Proportional PressureReducer
Reducer
The 3-way control device is a small selector valve The proportional pressure reducer is a valve that has
The 3-way control device is a small selector valve which: The proportional pressure reducer is a valve that has a control
which: a control chamber permanently connected to the
1.Permits passage
1. Permits passageof the
of thecontrol
controlmedia intointo
media the main
the valve chamber
downstream.permanently connected to the downstream.
control chamber (initiating the "closing"
main valve control chamber (initiating the procedure), This
This valvemust
valve mustbe bea adouble
doublechamber
chamber [D][D]type.
type.
or “closing” procedure), or The
The balance of hydraulic forces createdbetween
balance of hydraulic forces created betweenthethehigh
2.2. Permits
Permitsdrainage
drainage ofofthe
thecontrol
control media
media from
fromthethe
control pressure on theon
high pressure small
theseal area,
small and
seal the and
area, lower downstream
the lower
chamber to the
control atmosphere
chamber to the (initiating the "opening"
atmosphere procedure).
(initiating the pressure
downstream on the larger diaphragm
pressure area,diaphragm
on the larger causes a fixed ratio
“opening” procedure). ofarea,
inlet/outlet
causes pressure of approximately
a fixed ratio of inlet/outlet 3:1.
pressure of
Some
Someofofthethe3-way
3-waycontrol
controldevices
deviceshave
haveaathird
thirdmode as approximately 3:1.
well,
mode which prevents
as well, which inflow
prevents or outflow
inflow orfrom the from
outflow control No
Noother
othercontrol
controldevice
deviceisisneeded.
needed.
chamber, so chamber,
the control that the main valve
so that theremains fixedremains
main valve when the
device is in this
fixed when themode.
device is in this mode.
This
Themode
3-wayismode
used is
in used
on-offinvalves
on-offorvalves
whenor thewhen
regulating
the regulating valve is fully open, in order to obtain Separation
valve is fully open, in order to obtain specific operating Disc
specific operating
conditions. conditions.
Once in position, thereOnce
is noinwater
position,
flow there
through
is no water flow through the control chamber.
the control chamber.
The 3-way control circuit may open the main valve
The 3-way control device may open the main valve entirely,
entirely, creating minimum head loss.
creating minimum
The 3-way controlhead loss.must be used when
device
The 3-way media
external control (not
device must be
pipeline used when
water) is usedexternal media
to control
(not
thepipeline
valve, orwater)
when istheused to control
control mediathe valve,
is dirty oror when
the control media is abrasive.
abrasive.
Closed Valve
Open Valve
Open Mode
Edition 09/2018
Return Flow
Series 300 Valves Engineering Data
Saughton Hall under 100mm DOROT 300 Series CX Pilot Control Flow logged at 15 Minute
80 intervals 9
80 9
70 8
70 8
7
60 7
60
6
50 6
Pressure Metres
50
Flow Litre/sec
5
40 5
40 4
4
30
30 3
3
20
20 2
2
10 1
10 1
0 0
0
9.2.2001 10.2.2001 11.2.2001 12.2.2001 13.2.2001 14.2.2001 15.2.2001 0
16.2.2001
9.2.2001 10.2.2001 11.2.2001 12.2.2001 13.2.2001 14.2.2001 15.2.2001 16.2.2001
60
50
50
40
40
30
30
20
20
10
10 Unstable regulation zone
0 Kn
0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Kn
Kv
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Kv
10
Edition 09/2018
Engineering Data Series 300 Valves
Cavitation Data
Inlet
Inlet pressure
pressure
psi mwc
360 250
240
340
230
320 220
210
300
200 Noisy
Noisy
280 190 Destructive
Destructive Operating
Operating
Cavitation
Cavitation
260 180
170
240
160
Case II
Case- 2
220 150
140
200 Case-1I
Case
130
180
120
160 110
CaseIII
Case- 3
100
140
90
120 80
100
70 Safe
Safe
60 Operating
Operating
80
50
Conditions
conditions
60 40
30
40
20
20 10 Outlet
Outlet
0 pressure
pressure
10 20 30 40 50 60 70 80 mwc
10 20 30 40 50 60 70 80 90 100 110 psi
Cavitation Chart
Limits of operating conditions
The chart above sets the safe limits for valves that are supposed to operate at a considerable pressure
differential.
Such conditions generate noise and possible cavitation damages to the valve body.
How to use the chart:
i. Determine the maximal dynamic pressure that may be applied in the inlet of the valve.
ii. Draw an horizontal line from the pressure scale at the left side of the chart
iii. Find the requested outlet pressure in the pressure scale at the bottom of the chart.
iv. Draw an upward line at this point.
v. The intersection of the two lines defines the cavitation characteristics of the valve operation.
- In the case that it falls in the RED zone (case I)- the valve may be damaged in a fairly short time.
- In the case that it falls in the YELLOW zone (case II)- the valve may generate a noise that exceeds 80db.
- In the case that the intersection is within the GREEN zone (case III)- the valve will perform safely and quietly
General remark: The cavitation and noise data are based on tests done by the Utah State University, US, and Delft Hydraulic Laboratories, Holland.
11
Edition 09/2018
Series 300 Valves Engineering Data
H TH
H TH
Angle Type AH
AH
Valve Size 50 (2”) 80 (3”) 100 (4”) 150 (6”) 200 (8”) 250 (10”) TR
R inch AR
mm inch mm inch mm inch mm inch mmR mm inch AR TR
AL 208 83/16 250 913/16 295 111/16 405 16 505 197/8 585 23
AH 240 97/16 415 165/16 445 171/2 570 227/16 635 25 832 323/4
AW 170 611/16 200 77/8 235 91/4 330 13 415 165/16 495 LL191/2 AL
AL
AR 107 43/16 138 57/16 147 513/16 180 71/16 302 117/8 338 135/16
AB 125 415/16 150 57/8 173 613/16 240 97/16 300 1113/16 338 135/16
W AW TW
Weight kg/lbs* 12 / 26 20 / 44 37 / 81 76 / 167 150 W
/ 330 234 / 550 TW
AW
AB
Globe Threaded Type Grooved Type AB
Valve Size 40 (11/2”) TH 50 (2”) TH Valve Size 50 (2”) 80 (3”) 100 (4”) 150 (6”)
mm inch h mm inch mm inch mm inch mm inch mm inch
TL 215 87/16 215 87/16 VL 215 81/2 351 1313/16 376 1413/16 521 201/2
TH 185 7 /16
5
185 75/16 VH 173 613/16 228 9 240 97/16 330 13
TH
h 140 51/2 140 51/2 h 140 51/2 170 611/16 180 71/16 230 91/16
AH h
TW 129 5 129 5 VW 128 5 197 73/4 236 95/16 331 131/16
TR 62 23/8 62 23/8 VR 78 3 106 43/16 118 45/8 147.5 513/16
AR TR
Weight kg/lbs* 7 / 15 7 / 15 Weight kg/lbs* 6.5 / 14.5 15.1 / 33.25 26.5 / 58.5 58.25 / 128.5
VH
h h
AL TL VL
TH VH VR
AW TW VW
VR
AR TR
AB
* Approximate shipping Weight (PN 25) • End Connections (for PN16 or PN25)
** h = MinimalTLrequired maintenance space • ISO 2084, 2441, 5752 ANSI B16, AS2129, JIS B22
VW
TW
12
B Edition 09/2018
Engineering Data Series 300 Valves
Grooved Type
Valve Size 80 (3”) 100 (4”) 150 (6”) h
mm inch mm inch mm inch
VL 310 123/16 348 1311/16 480 201/2
VH 173 613/16 228 9 330 13 VH
h** 107
h 43/16 156 61/8 230 91/16
VW 128 51/16 197 73/4 331 131/16
VL
VR 78 31/16 105 41/8 122 513/16
VH VR
Weight kg/lbs* 6.5 / 14.3 15 / 33 48 / 105
VW
VR
VL
* Approximate shipping Weight (PN 25)
** h = Minimal required maintenance space
13
Edition 09/2018
Series 300 Valves Engineering Data
Globe Type
Flow Rate Factor: Kv (Metric) 43 43 43 115 167 407 676 1160 1600 1600 3000 3150 3300 6500 6500 6500
Cv (US) 50 50 50 133 195 475 790 1360 1900 1900 3500 3700 3860 7600 7600 7600
Head Loss Factor K (dimensionless) 2.2 5.4 15.4 4.8 5.6 4.8 5.5 4.5 5 9 3.8 6 5.9 4.8 8.9 15.2
Angle Type
For head Loss of fully open valves use the following equations:
Flow Rate Factor: Kv (Metric) 60 60 140 190 460 770 1310
Cv (US) 70 70 164 222 537 900 1533 H (Bar) = (Q [m /h]) H (Psi) = (Q [gpm]) H=K V
3 2 2 2
Kv Cv 2 g
Head Loss Factor K (dimensionless) 1.3 2.8 3.3 4.3 4.3 4.2 3.6
Kv 43 115 165 345 663 1160 1600 1600 3000 3000 3000
Flow rate factor:
Cv 50 133 192 400 770 1360 1900 1900 3500 3500 3500
14
Edition 09/2018
psi mwc
MODEL 32 (GLOBE PATTERN) PRESSURE LOSS CHART
10
psi mwc 8
10
Engineering Data
10
Series 300 Valves
0m m
9
6
8 8
, 60
"
", 24
10 7 5
0 mm
0 mm
0m m
,16"
, 20
9 6
6
, 40
, 50
8 4
14"
18"
12" m, 60
"
mm
mm
", 24
7 5 5
0 mm
m
mm
,16" m
mm
, 20 m
m
10"
350
450
0m
m
142"00m
182" 50m
4"
80m
8"
3"
6"
3
100
150
300
6
, 40
, 50
4 4
mm
mm
5
mm
m
m
m
10"
350
450
m
m
12"
4"
80m
8"
3"
6"
3
Headloss Charts 3
100
150
200
250
300
4 2
3 2
2
MODELS 30 \ 31 (GLOBE PATTERN) PRESSURE LOSS CHART
Models 30/31 (Globe Pattern) Pressure Loss Chart 2 1
10 100 1,000 10,00
psi mwc 1 100 1,000 10,000
10 10 100 1,000 10,000 m3/hr
3w 2w
8 100 1,000 10,000 gpm
10
9
6 M3O
w DEL 32 (GLOBE2P
wATTERN) PRESSURE LOSS CHART
0 mm
0 mm
8
mm
mm
7 psi mwc
,80
65 ,
, 50
450 ",20 "
, 70 8 ", 32 "
,mm "
mm, 4 "
350
mm
mm
mm
mm
0 mm
6
m
mm
4 10
250 "
1
150 "
100 "
80m
200 "
10
3"
40m ½ ", 2"
8
6
4
12 " ,
8
600 24" , 2
400 16" ,1
5
psi mwc 8
300
mm ,
1
mm
3
4 10 10
0m m
9
6
8 8
, 60
"
", 24
3 10 7 5
0 mm
0 mm
2
0m m
,16"
, 20
9 6
6
, 40
, 50
8 4
14"
18"
12" m, 60
"
mm
mm
", 24
2 7 5 5
0 mm
m
mm
,16" m
mm
, 20 m
m
10"
350
450
0m
m
142"00m
182" 50m
4"
80m
8"
3"
6"
3
100
150
300
6
, 40
, 50
4 4
mm
mm
1 5
m
mm
m
m
m
10,000 m3/hr
10"
350
450
m
m
10 100 1,000
12"
4"
80m
8"
3"
6"
3 3
100
150
200
250
300
4 2
50 100 1000 10,000 gpm
3 2
3w 2 2w
ModelsMODELS
30A/31A (Angle
30A \ 31A (ANGLE PATTERN)Pattern)
PRESSURE LOSSPressure
CHART Loss Chart 2 1
10 100 1,000 10,00
psi mwc 1 100 1,000 10,000
10 10 100 1,000 10,000 m3/hr
3w 2w
8 100 1,000 10,000 gpm
10
9
8
6 M3O
w DEL 32 (GLOBE2P
wATTERN) PRESSURE LOSS CHART
7 5
0 mm
psi mwc
mm
mm
mm
mm
6
m
40m ", 2"
4"
m ,5
6"
80m
10
8"
10
200
100
150
1½
5
3 psi mwc 8
4
10 10
0m m
9
6
8 8
, 60
3
"
2
", 24
10 7 5
0 mm
0 mm
0m m
,16"
, 20
9 6
6
, 40
, 50
8 4
14"
18"
12" m, 60
"
2
mm
mm
", 24
7 5 5
0 mm
m
mm
,16" m
mm
, 20 m
m
10"
350
450
0m
m
142"00m
182" 50m
4"
80m
8"
3"
6"
3
100
150
300
6
, 40
, 50
1 4 4
mm
mm
mm
m
m
m
10"
350
450
m
m
12"
4"
80m
8"
3"
6"
3 3
100
150
200
250
300
3w 3 2w 2
2
Model 32 MODEL
(Globe Pattern)
32 (GLOBE Pressure
PATTERN) PRESSURE LOSS CHART Loss
2 1
10 100 1,000 10,00
psi mwc 1 100 1,000 10,000
10 10 100 1,000 10,000 m3/hr
3w 2w
8 100 1,000 10,000 gpm
10
0 mm
9 3w 2w
6
8
60
"
" , 24
m,
7 5
0 mm
00 m
16 "
, 20
6
, 40
4
14",
18"
m, 5
mm
5
m
mm
mm
mm
mm
m
10 "
350
450
m
12 "
4"
3"
8"
80m
6"
3
100
150
200
250
300
3
2
1
10 100 1,000 10,000 m3/hr
50 100 1000 10,000 gpm
3w 2w
15
Edition 09/2018
Series 300 Valves Engineering Data
Components
Bonnet Assembly
Spring
Double-Chamber Diaphragm
Conversion Kit Assembly
Body Assembly
‘F’ Version
Conversion Kit
16
Edition 09/2018
Electronic and Remote control functions Series 300 Valves
4
5
Dorot s-300-30-EL
Electric Control Valve
Isolation Valve 3 1
* Indicatative drawing
Main Control System Components
1 Main Valve
2 Ball valve
3
4
Self-flushing filter
3/2 Solenoid Valve
17
5 66-210 Relay – Above size 8"
Edition 09/2018
Series 300 Valves Electronic and Remote control functions
4
5
Dorot s-300-30-EL\TO
Electric Control Valve
2
Isolation Valve
* Indicatative drawing
3 1
Isolation Valve 4
4
Strainer
1 2 1 2
ConDor
Controller
Dorot Flowmeter 5
Dorot s-300-30-EC
Electric Control Valve 2
3 1
Isolation Valve
* Indicatative drawing
19
Edition 09/2018
Series 300 Valves Pressure regulating functions
Dorot DAV-M
Isolation Valve Air Valve 4 5
2
Strainer
Dorot S-300-30-QR
Pressure Relief
Valve
Dorot s-300-30-PR
Pressure Reducing Valve
Isolation Valve 2 2
3 1
Main Control System Components
1 Main Valve
* Indicatative
2 drawing
Ball valve
3 Self-flushing filter
4 2W PR Pilot Valve
5 Pressure Gauge
20
Edition 09/2018
Pressure regulating functions Series 300 Valves
Isolation Valve
3
Dorot s-300-30-QR
Strainer Pressure Relief Valve
Dorot DAV-M
Air Valve
Dorot s-300-30-PR[D]
Differential Pressure
Reducing Valve
Dorot s-300-30-PR 2
Pressure Reducing Valve
Isolation 1
Valve
Isolation Valve
Main* Indicatative
Control drawing
System Components
1 Main Valve
2 Ball valve
3 Nozzle 21
Edition 09/2018
Series 300 Valves Pressure regulating functions
Dorot DAV-M
Isolation Valve Air Valve 4
2 5
Strainer
Dorot S-300-30-QR
Pressure Relief
Valve
Dorot s-300-30-PRM[E2]
Pressure Reducing Valve
Isolation Valve 2
2
3 1
Main Control System Components
1 Main Valve
2 * Indicatative
Ball valvedrawing
3 Self-flushing filter
4 2W PRM Pilot Valve
5 Pressure Gauge
22
Edition 09/2018
Pressure regulating functions Series 300 Valves
30-HyMod Flow-Modulated
Pressure-Reducing Valve
Principal of operation
Dorot model ‘HyMod’ is an automatic pilot controlled,
flow-modulated pressure reducing valve activated by
the pressure of the pipeline. The valve reduces upstream
pressure to a downstream pressure that increases or
decreases simultaneously with the demand flow. The
pressure into the zone is continually adjusted according
to the zone’s actual demand, thus compensating for the Purchase Specifications
system loss. The pressure-flow profile can be adjusted • The valve will be hydraulic, pilot-operated globe type.
The Dorot HyMod will control from no flow, to maximal • Face-to-face length dimension meets ISO 5752 Standard.
full open flow without any chattering or slamming. • The stem will be guided at the top by a replaceable guide
bearing and at the bottom by a stainless steel unique LPT®
Features device.
• The valve will regulate any flow within the specified range
• Superb performance: without the need for a smaller bypass valve or throttling plug.
∙∙ Regulates at a stable mode, regardless of valve-size, down • All control ports will be corrosion free protected by stainless
to near-zero flow. Thus, eliminating the need for a special steel 316 inserts.
low flow plug-design (such as ‘V-port’) or a bypass valve.
∙∙ ‘Floating’, low-friction internal-trim design, guided by
Design Considerations
unique LPT® device.
• High reliability: • The valve should be suited for the maximal flow and allowed
∙∙ All control ports are fitted with SST sleeves for preventing Headloss.
corrosion-blockage. • In case upstream pressure may drop below the required
∙∙ Pre-shaped reinforced diaphragm – for easier assembly set pressure, select a 3-way control pilot.
and improved longevity. • Large pressure differentials may cause cavitation
• Reduced periodic inspection/maintenance labor: damage. Consult Dorot for solutions if such conditions
∙∙ The control-trim is fitted with a self-flushing, inline control- are expected.
filter.
∙∙ Easy in-situ adjustment and maintenance. Quick Sizing
• Versatility:
• Valve sized to be the same as line-size or one nominal-size
∙∙ A standard and simple single-chamber valve design,
smaller.
provides smooth operation. Conversion to a double
• Maximum recommended flow velocity for continuous
chamber is a patented option.
operation 5.5 m/sec (18 ft. /sec).
Standard Materials
Pressure rating
• Body & Cover – Ductile Iron
• Model 30, 30A for medium pressure (PN16 bar / 250 psi)
Optional – Cast Steel, SST, N.A.B, S.Duplex
• Model 31, 31A for high pressure (PN25 bar / 360 psi)
• Main Internal – SST (1.5”-6), Coated steel (8”-32”)
Optional – Cast Steel, SST, N.A.B, S.Duplex
• Elastomers – EPDM
Optional – NBR, Neoprene, Viton or others
• Coating – Polyester, Epoxy / Optional – Halar and others
• Control trim – Brass, PA / Optional – SST316, Duplex
23
Edition 09/2018
Series 300 Valves Pressure regulating functions
Isolation Valve
Dorot s-300-30-BC
Pump Control Valve
Isolation 2 2
Isolation Valve Valve
3 1
Main Control
* Indicatative drawing System Components
1 Main Valve
2 Ball valve
3 Self-flushing filter
24 4 2W PR Pilot Valve
5 Pressure Gauge
Edition 09/2018
Pressure regulating functions Series 300 Valves
Isolation Valve
⅜"
2
Dorot s-300-30-PS 2 2
Pressure Sustaining Valve
3 1
Main Control
* Indicatative drawing System Components
1 Main Valve
2 Ball valve
3 Self-flushing filter
4
5
2W PS Pilot Valve
Pressure Gauge
25
Edition 09/2018
Series 300 Valves Pressure regulating functions
2
Dorot S-300-30-QR
Pressure Relief
Valve
Dorot s-300-30-PR\PS
Pressure Reducing Valve
Isolation Valve
2
1
3
* Indicatative drawing
Main Control System Components
1 Main Valve 4 2W PS Pilot Valve
2 Ball valve 5 2W PR Pilot Valve
26 3 Self-flushing filter 6 Pressure Gauge
Edition 09/2018
Pressure regulating functions Series 300 Valves
Dorot s-300-30-DI 2 2
Pressure Diffrential
Sustaining Valve 3 1
* Indicatative drawing
Main Control System Components
1 Main Valve
2 Ball valve
3
4
Self-flushing filter
2W CXSD Pilot Valve
27
Edition 09/2018
Series 300 Valves Rate of Flow Regulating functions
5
2
2
3
Dorot s-300-30-FR
Flow Control Valve 2
6
1
2
* Indicatative drawing
28
Edition 09/2018
Rate of Flow Regulating functions Series 300 Valves
Dorot s-300-30-FR
Flow Control Valve
6
1
2
* Indicatative drawing
29
Edition 09/2018
Series 300 Valves Water Level Control functions
2
5
4
Isolation Valve
⅜"
2
Dorot s-300-30-FL 3 1
Modulating Float Control Valve
Edition 09/2018
Water Level Control functions Series 300 Valves
5
4
1
Isolation Valve
2
Dorot s-300-30-FLEL 2
Electric Float Control Valve 6
1
3
* Indicatative drawing
31
Edition 09/2018
Series 300 Valves Water Level Control functions
*Optional Addition: FLDI\SP Stepped Surge-Preventing Closure or ‘FR (PR)’ Flow control function.
5
C A
Isolation Valve
O
Dorot s-300-30-FLDI 2
1 6
Differential Float Control Valve
3
* Indicatative drawing
32
Edition 09/2018
Water Level Control functions Series 300 Valves
Isolation Valve 8 5
C A
6
2
Dorot s-300-30-FLDI\PS
Differential Float and Pressure 3
Sustaining Valve 1
* Indicatative drawing
33
Edition 09/2018
Series 300 Valves Water Level Control functions
4
5
C A
9 O
Isolation Valve ⅜"
10
⅜"
⅜"
8
2
Dorot s-300-30-FLDI\FR(PR)
Differential Float and Flow 2
Control Valve 3 1 6
* Indicatative drawing
34
Edition 09/2018
Water Level Control functions Series 300 Valves
4
5
Isolation Valve C A
O
7
8
C O
Dorot s-300-30-FLDI\SP
I
35
Edition 09/2018
Series 300 Valves Water Level Control functions
5
C A
O
Isolation Valve
6 7
2
Dorot s-300-30-AL 1
Altitude Pilot Control Valve
* Indicatative drawing 3
36
Edition 09/2018
Water Level Control functions Series 300 Valves
Isolation Valve 2
5
2
2
1
Dorot s-300-30-CXAL 3
Altitude Pilot Control Valve
* Indicatative drawing
37
Edition 09/2018
Series 300 Valves Pump Control functions
Isolation Valve
7
8
1 2
Isolation Valve
Dorot s-300-30-BC 7
5 3
Pump Control Valve
6
Isolation Valve
Dorot DAV-M 7
Air Valve
4 4
* Indicatative drawing
Main Control System Components
1. 3/2 hyd. relay-valve model 66-210 8. Needle Valve
2. 3/2, N.C Solenoid valve
3. 3/2 hyd. relay-valve model 28200
38 4.
5.
isolation ball-valve
Limit switch assembly
6. ‘Y’ pattern control-filter
7. Check valve
Edition 09/2018
Pump Control functions Series 300 Valves
Isolation Valve
1
2
Isolation Valve 8
Dorot s-300-30-BC\PS 7
Pump Control Valve 9
5
Isolation Valve 7 3
Dorot DAV-M
Air Valve
4
4
* Indicatative drawing 6 6
39
3. 3/2 hyd. relay-valve model 28200 8. Needle Valve
4. isolation ball-valve 9. Pressure gauge
5. Limit switch assembly
Edition 09/2018
Series 300 Valves Pump Control functions
Dorot s-300-30-NS 3
Two-Stages, check valve
Isolation Valve
2
1
* Indicatative drawing
Main Control System Components
1 Main Valve
2 Ball valve
40 3 Line filter
4 NS device
Edition 09/2018
Pump Control functions Series 300 Valves
Dorot s-300-30-CV
Non-Return Valve
Isolation Valve 2
Edition 09/2018
Series 300 Valves Pump Control functions
5
2 2
Dorot Check-Valve
1 2 2 1
Dorot DAV-M 7
Air Valve
4 3
3 1
Dorot s-300-30-DW
Deep Well Pump
Control Valve
Isolation Valve
* Indicatative drawing
42
Edition 09/2018
Safety functions Series 300 Valves
2
Dorot DAV-M
Air Valve 8
9
6
Dorot s-300-30-BC
Pump Control Valve Main Control Sys
3 1 Main Valve
2 Ball valve
Dorot s-300-30-RE 3 Filter
4 2W Pilot Valve
Surge Anticipating Valve 2 5 3W Pilot Valve
6 Fast Acting Rela
Main Header 7 Pressure Gauge
8 Needle Valve
1 9 Check Valve
* Indicatative drawing
43
Edition 09/2018
Series 300 Valves Safety functions
Dorot DAV-M
Air Valve
6
Dorot s-300-30-BC 3
Pump Control Valve Main Control Syste
1 Main Valve
2 Ball valve
2 3 Filter
Dorot s-300-30-REEL 4 2W Pilot Valve
Surge Anticipating Valve 5 Solenoid Valve
Main Header
6 Fast Acting Relay
7 Pressure Gauge
* Indicatative drawing 1
44
Edition 09/2018
Safety functions Series 300 Valves
Dorot s-300-30-PRM[HyMod]
Pressure Reducing Valve
Isolation
Valve 2 2
Isolation Valve
3 1
* Indicatative drawing
Main Control System Components
1 Main Valve
2 Ball valve
3
4
Self-flushing filter
2W PS Pilot Valve
45
5 Pressure Gauge
Edition 09/2018
Series 300 Valves Safety functions
⅜"
Dorot s-300-30-FE
Excessive Flow Shutoff Valve 3
2
5
3 1
* Indicatative drawing
46
Edition 09/2018
Fire Protection Applications Series 300 Valves
The Dorot 300 series valves are UL-listed to be used in Fire Protection
Systems at various ranges of applications.
Deluge Valves
The Dorot UL Deluge Valves are suitable for systems that include Electric,
Hydraulic or Pneumatic detections. The Dorot 300 series Deluge Valves
DE/EL
are activated by each signal or by combinations thereof. All applications
are equipped with a manual emergency actuation valve and approved
for use in Fire Protection Systems as Automatic Reset or Manual Reset
Valves.
Monitor Valves
The Dorot 300 Series Monitor Valves are designed to open immediately
as a response to Electric, Hydraulic, Pneumatic or manual activation.
The valves use the line pressure to develop maximum power and do not
need any external source of power.
The Dorot 300 Series Monitor Valves are designed to be activated locally
or remotely.
PR/UL
The Dorot 300 Series UL Pressure Reducing Valves are designed to
maintain constant downstream pressure at all flow conditions.
47
Edition 09/2018
Innovation
Innovation
Expertise
Expertise
Reliability
Reliability
www.dorot.com