Web Enabled Network Control Unit

Features Description

Embedded Web Server. The GCU9001 is a Web enabled network control unit that uses
Ethernet and TCP/IP networking technologies. It incorporates an
Easy control & monitor via web browser
embedded web server that can deliver user-specific web pages to
complete with security protection. any PC or mobile terminal running internet browser software. A
Ethernet 10/100 Mbps connection and user with an appropriate security codes can made adjustment or
monitor the network control unit form any internet access point in
use TCP/IP networking technologies. the world.
Support Standard Multi Protocols –
It is also provides network management, integration and process
BACnet & Modbus
control functions for any existing or new building controllers and
Telnet support for uploading and microprocessor based equipments or system in buildings.
downloading of database & online The management function provided by the GCU9001 such as
trend log and alarm generation improves building controllers and
modification.
microprocessor based equipments or system management and
Support Multi-System For Seamless audit trail capabilities.
Integration or Router function.
The integration function provided by the GCU9001 allows
Built-in soft ladder logic for process seamless integration such as information sharing (read/write)
control. between building controllers and microprocessor based
equipments or system without any need of major upgrade or
Support time schedule & holiday
equipments replacement and allow cost saving.
function.
Support trend (real-time & historical) The process control functions provided by the GCU9001 allow
global control action to be implemented across any building
logging and storage function. controllers and microprocessor based equipments or system to
Support real-time alarm generation and allow full building control.
storage function.
The GCU9001 provide a truly cost effective solution for any
Support E-mail, SMS and voice building automation or high-level integration application. A truly
notification based on alarm/change of Ethernet network compliant feature allows the GCU9001 to be
install anywhere in the building.
state condition.
16-bits, On-board A/D Convertor.
12-bits, On-board D/A Convertor.

Pegasus reserves the right to revise this publication from time to time and make changes to the content hereof without obligation to notify any person of such revisions or changes.

GCU9001 Data Sheet Issue 1.0 2/03/14 1


Firmware Specifications
Can be access at anytime & anywhere via internet browser.
Allow platform cross over development and code pot over for new software
Web based compliant application features.
Building automation or high level integration data can be co-exist on existing
IT Ethernet networks.
Allows graphics pages navigation from one page to another page.
Allows simple mouse click to operate command or viewing.
Built GUI Interface
No additional software required (all require programs have been embedded
in the firmware).
Standard Web Programming
Use Java Scripts, Java Applets, and CGI Scripts programming.
Languages
Support Protocols For High Level
BACnet/IP, BACnet/MSTP, Modbus/IP, Modbus RTU, UDP and URL.
Integration
FTP Support A file size can be upload or download via FTP command
I/O Database Capacities Support up to 1023 I/O points capacities with full functions.
Unlimited Time schedule configuration up to 5 years in advance for all I/O
Time Scheduling Function
points.
Unlimited Holiday schedule configuration up to 5 years in advance for all I/O
Holiday Scheduling Function
points.
All I/O points can be configured for trend log function with log sample size of
1,000,000 (max.) samples for each I/O point.
Allow more than a year storage space for data samples for each point with
sample rate of 1 minutes interval.
Trend Logging Function
Built-in real-time or historical line chart into firmware.
All log data samples are fully self-contained into the unit flash memory.
All trend log data samples can be converted into CSV file format
automatically upon up loading from the unit (Data format is Excel ready).
All I/O points can be configured for alarm with up to 5 alarm stages (out of
range, high, high high, low & low low) for each I/O point.
Alarm Management Function
All alarms are fully self-contained into the unit flash memory up to 1,000,000
(max.) alarms history.
All I/O points can be configured to sent out messages via E-mail, SMS or
Voice based on alarm state (normal to alarm), return to normal state (alarm
to normal), any change of state, rate of change and time based. Each
Alarm Notification Function message has complete details of the alarm/event with point ID, event,
condition, additional user configure information, time and date stamp.
All message can be received by mobile phone any where in the world via
standard Internet gateways
Support Pegasus logic (soft logic) programming for process control. All I/O
points can be use as input (source) or output (destination) by the ladder
Process Control Function
logic program. Built-in function such as PID, Gate, Logic, Comparator, etc
will simplify, speed up user programming time and learning curve.

Pegasus reserves the right to revise this publication from time to time and make changes to the content hereof without obligation to notify any person of such revisions or changes.

GCU9001 Data Sheet Issue 1.0 2/03/14 2


Hardware Specifications
Power Supply 24VDC / 24VAC
Power Consumption 18 Watt
Microprocessor 32 Bits – ARM 9 450MHz
SDRAM Memory 512 MB DDRII 533 MHz
NAND Flash Memory 512 MB
Main Network Ethernet (TCP/IP) – support 10/100 MBPS connection (auto detect)
Serial Communication Ports 3 x RS-485
Serial Communication Baud Rate 50 ~ 230.4 KBPS
Serial Communication Distance Maximum Length: 1000 meters using screened twisted pair 24AWG
Yes, Allows configuration of a predefine tasks/events to run based on time
Real Time Clock & Calendar
and date automatically
6 x 10K thermistors or 6 x 4 to 20mA or 6 x 0 to 10VDC. Accuracy: 0.1%
Universal Inputs
full scale or 6 x for reading contact closures or pulse
12 x for reading contact closures directly complete with surge protection
Digital Inputs
(Photo-coupler Type)
Analog Outputs: 4 x 0-10VDC or 4 x 0 to 20mA. Resolution: 0.4% full scale
5 x Relay Dry Contacts with contact rating of 240VAC maximum 7Amps (2
Digital Outputs:
Relay Outputs have Normally Open & Normally Close Contact).
Storage Condition -20 to 70 Deg C / 0% - 90% RH, Non - Condensing
Operating Condition -5 to 65 Deg C / 0% - 90% RH, Non - Condensing
Surge Protection 15KV ESD for serial port
Magnetic Isolation 1.5KV for Ethernet
Dimensions 144 mm x 114 mm x 76 mm
Weight 500 g