You are on page 1of 14

DESIGN OF STRUCTURE

FOR
60MX16M HANGAR GATE

FABRIC HOIST UP DOOR

&SIDE COLUMN
DOCUMENT NO. HC-1814-01-R6

DEC, 2018

CLIENT:-
CPWD, NEW DLEHI

CONTRACTOR:
TEMPCON ENGINEERS
4, CENTRAL LANE BENGALI MARKET
NEW DELHI 110001
STRUCTURAL CONSULTANT:

HC/ TEMPCON File: 420589595.xlsx - Sheet: Cover Status: 05/14/2019


DESIGNED BY: SUDHANSHU SHEKHAR CHECK BY: S.L.MAHAJAN

HC/ TEMPCON File: 420589595.xlsx - Sheet: Cover Status: 05/14/2019


HC/ TEMPCON File: 420589595.xlsx - Sheet: Cover Status: 05/14/2019
HC/ TEMPCON File: 420589595.xlsx - Sheet: Cover Status: 05/14/2019
INTRODUCTION/ DESIGN CRITERIA Page:5 of 14

BMA/ ABCI/ NF Rly. File: 420589595.xlsx - Sheet: DSGN-CRIT Status: 05/14/2019


INTRODUCTION/ DESIGN CRITERIA Page:6 of 14

1.0

1.1

Book

IS: 875-1987

IS: 875(3)-2015

IS: 1893;
(Part-I)-2002

IS: 456-2000

1.2

IS: 269-1989

BMA/ ABCI/ NF Rly. File: 420589595.xlsx - Sheet: DSGN-CRIT Status: 05/14/2019


INTRODUCTION/ DESIGN CRITERIA Page:7 of 14

IS: 2062-2006
IS: 1148-(Latest)
+A76

IS:1929-1961

IS:2155-(Latest)
IS:814

IS :816

IS:9103-1979

IS:102-1962

IS:2502-1963

IS: 9595 - 1980

IS: 7215-1974

IS:10262

IS:800-2007

IS:13920-2016

IS:4923-1997

BMA/ ABCI/ NF Rly. File: 420589595.xlsx - Sheet: DSGN-CRIT Status: 05/14/2019


INTRODUCTION/ DESIGN CRITERIA Page:8 of 14

IS:4091-1979

2.0

Dead Loads
Live Loads

Wind Loads.

Earthquake
Loads

Structural Steel

3.

BMA/ ABCI/ NF Rly. File: 420589595.xlsx - Sheet: DSGN-CRIT Status: 05/14/2019


INTRODUCTION/ DESIGN CRITERIA Page:9 of 14

4.

5.

6.

(i)
(ii)
(iii)

(iv)

BMA/ ABCI/ NF Rly. File: 420589595.xlsx - Sheet: DSGN-CRIT Status: 05/14/2019


INTRODUCTION/ DESIGN CRITERIA Page:10 of 14

Design Criteria Designing, structure, assembling


of fabric hoist up door & side column

BMA/ ABCI/ NF Rly. File: 420589595.xlsx - Sheet: DSGN-CRIT Status: 05/14/2019


INTRODUCTION/ DESIGN CRITERIA Page:11 of 14

Codes And Standards

The structural design will basically conform to the latest revision of codes
and recommendation of INDIAN STANDARDS specifications.

For manufactured items the recommendations of manufacturer for


PROPRIETORY ITEMS regarding the use, design criteria, installation
instructions and properties will be adopted with appropriate guarantees for
performance.

The following are the various Design Codes that shall be followed for
the structural design of the various components of structure. These shall
be supplemented, wherever required, by guidelines from various
international codes and literature issued by different Government of India
Undertakings.

Design of steel structures By Prof. S.Ramamrutham, published by-


Dhanpat rai publishing company

Code of practice for Structural safety of building and loading

Code of practice for Design Loads for buildings and structures

Criteria for Earthquake Resistant design of structures (Part-I).

Code of practice for plain and reinforced concrete.

The following are the various Design Codes that shall be followed for
the material specification.

Ordinary Grade Portland Cement.

BMA/ ABCI/ NF Rly. File: 420589595.xlsx - Sheet: DSGN-CRIT Status: 05/14/2019


INTRODUCTION/ DESIGN CRITERIA Page:12 of 14

Hot rolled Low, Medium & High tenile Structural Steel


Hot rolled steel river bar (upto 40mm dia.) for structural purpose

Rivets for general purpose (12mm to 48mm dia.)

Rivets for general purpose ( upto 12mm dia.)

Covered electrodes for Manual Metal Arc welding.

Code of Practice for use of Metal Arc Welding for General Construction in
Mild Steel

Admixture for concrete

Ready mixed paint, brushing, red lead, non-setting priming

Code of practice for bending and fixing of bars for concrete reinforcement

Indian Standard Recommendations for Metal Arc Welding of Carbon


Manganese Steels

Tolerances for Fabrication of Steel Structure

Concrete Mix Design.

Code of practice for general construction in steel

Code of practice for Ductile detailing of reinforced concrete structures

Specifications of hollow steel sections for structural use

BMA/ ABCI/ NF Rly. File: 420589595.xlsx - Sheet: DSGN-CRIT Status: 05/14/2019


INTRODUCTION/ DESIGN CRITERIA Page:13 of 14

Code of practice for design and construction of foundations for transmission


line towers and poles.

Design Standards

The following is a summary of the various Design Standards that will be


adopted for the various structural components of bridges
Design Loading
As per IRS Bridge Rules
As per Door manufacturer recommended

Wind pressure effect on the structure as per clause wind pressure as per
IS-875-1987.

As per IS: 1893-2002 (Zone-IV )

Load Considered :-
Following loads have been considered while designing the structural
drawing for the Hangar Door
1. Hangar Door Weight
2. Self contained weight (weight of steel structure)
3. Wind Load
4. Temperature Rise & Fall

Material Specification:
Steel:
As per IS: 2062 Quality 'B' Grade designation E250 (Fe 410 W) fully
killed & normalised/ controlled cooled.

Welding Rod shall be used of reputed make

BMA/ ABCI/ NF Rly. File: 420589595.xlsx - Sheet: DSGN-CRIT Status: 05/14/2019


INTRODUCTION/ DESIGN CRITERIA Page:14 of 14

(Advani / Mangalam or equivalent)

The steel members / Plates shall be strictly as per grades


mentioned in design report. The make of Steel Shall be ISI.

In case the makes approved by CPWD is not available / delayed delivery


then similar make as per IS Standard (Tata Structra, APL Apollo,
Jindal, Surya etc.), duly approve by competent authority shall be used.

Door manufacturer recommended for 2x3 leg system structure as


per sketch attached. When the door is closed, wind load will be very
high causing appreciable foundation size. Due to large size of foundation,
it is required to keen the columns away from the existing wall and also
necessary to cover the space between door columns and existing
structure to make it waterproof and bird/ rat free, providing extra
structure to comply the requirements.
The structure designed is with 4 No column on either side without
which is may not be possible due to below mentioned reason:-
High Uplift/ downward force due to wind load on closed door;
Proper Load transfer;
Existing structure foundation overlapping with main load
bearing column;
Availability of space and adhering to the dimensions of door
manufacturer.
x-x-x

BMA/ ABCI/ NF Rly. File: 420589595.xlsx - Sheet: DSGN-CRIT Status: 05/14/2019