Kode Unit Embalut 2 BO-ESP

STANDART OPERASIONAL
No. Dok SOP. 6.1.010
PROSEDURE
Revisi 0
Tgl. Terbit 01 Januari 2015
BOILER DAN ESP UNIT 3
Halaman Page 1 of 1
START STOP COAL PULVERIZER (COAL MLL & COAL FEEDER) A/B/C
N PETUGAS
URAIAN Waktu KETERANGAN
O COHA WTP LAB BO TG ADM MEC ELK INC

1 Koordinasi dengan bagian


elektrik
1 1

2 Pengecekan kondisi unit

3 Koordinasi operator local


dengan operator DCS
2

4 Open motor control damper


from Cool PA

5 Open Pneumatik valve (Aeration


Barrier Valve ) coal pipe

6 Open Motor valve sealing

7 Open Valve Pneumatik Mixing


Start Condition ?
Tidak
3
Oke

Unit Normal ? Tidak Aktifkan proteksi


8 Start Coal Mill 12 4 interlock
Ya

9 Open Coal Feeder Outlet Valve

10 Unit Normal ? Tidak Aktifkan proteksi


Start Coal Feeder 11 5 5 interlock
Ya
Ingin Stop ? Tidak
Normal
Ya
11 Stop Coal Feeder Tempt. Separator? Lepas proteksi
interlock coal
<100 oC feeder dan coal
>100 oC mill

12 Stop Coal Mill 12

13 Close Sealing Valve


Selesai
2 Jam

Dibuat Oleh : Diperiksa Oleh : Diketahui Oleh : Disetujui Oleh :


Foreman Supervisor Superintendent Manajer Operasional

Khakim., Relianus., Maryadi Rudangi., Dwi., Arif Rosibel Ompusunggu Ach. Choirul Hudin