STRUCTURAL DESIGN (Type B)
Building Elements As Per Submitted Design Remark
General
Structural Aluminium
√ Brick
Masonry
Materials to be used in structure(tick the listed materials Timber
that will be used in structure element) Structural
Steel
√
RCC(Reinforcemen
t Bar) Stone
Masonry
Specify the design unit weight of materials: Steel (in kg/m 3) 7850
Specify the design unit weight of materials: RCC (in kg/m 3) 2500
Specify the design unit weight of materials: Brick Masonry (in kg/m 3)
1960
NBC 103-1994 Occupancy Load (Imposed Load)
Wind Zone 1
Seismic
Coefficient
Approach
√ Response Spectrum
Method adopted for earthquake resistant design Meth
od
Othe
rs
Adopted Code for Seismic Design IS 1893:2002
Type I (Hard)
√ Type II
Subsoil category (Medium) Type
III (Soft)
Seismic Weight (W) (in kN) 15249
Are you sure that all safety measures will be fulfilled in √ Yes
the construction site as per this code?
4 side continuous
1 short side
discontinuo
us 1 long
side
√ discontinuo
us 2
adjacent
Boundary condition of slab side
continuous
2 long
side
continuo
us 2
short
side
continuo
us 1 long
side
continuo
us 1
short
side
continuo
us
4 side
discontinu
ous
Effective Thickness of slab (d) (in mm) 107
Cantilever
Simply
supported
One side continuous
√
Support condition Both
side
continu
ous
Basic (L/d) ratio 26
11.35
1.48%
Load Combinations
1: DL 1.5
1: LL 1.5
1: EQ 0
2: DL 1.2
2: LL 1.2
2: EQ 1.2
3: DL 0.9
3: LL 0
3: EQ 1.5
4: DL 1.5
4: LL 0
4: EQ 1.5
Yes