QUALITY STANDARD FOR SLOPE & RETAINING STRUCTURE WORKS
Assessment
Item Element Standards Tolerance
Tool
1 SLOPES: ROCK, RIGID & SOFT SURFACE COVER
1a. General Requirements
ii) Installation • Anchorage points must remain intact and firmly Visual
fixed to the rock slope
2 RETAINING STRUCTURE
2a General Requirements
i) Crack and • No crack, damage and spalling of concrete Visual
Damage surface
ii) Joint, Filler • No missing, deteriorated joint filler and sealant Visual
and gaps
• Gaps between facing panels are free from any Visual
undesirable vegetation growth
-B 1-
QUALITY STANDARD FOR SLOPE & RETAINING STRUCTURE WORKS (continued)
Assessment
Item Element Standards Tolerance
Tool
2 RETAINING STRUCTURE (continued)
2a General Requirements (cont’d)
3b Surface Drain
i) Crack and • No visible crack, damage, and spalling Visual
Damage
ii) Joint, Filler • No missing or deteriorated joint filler and sealant Visual
and gaps Visual
• No gaps between drainage and soil
3c Subsurface Drain
i) Crack and • No crack, damage and spalling of concrete Visual
Damage surface
ii) Functionality • No traces of seepage Visual
-B 2-
QUALITY STANDARD FOR SLOPE & RETAINING STRUCTURE WORKS (concluded)
Assessment
Item Element Standards Tolerance
Tool
4 ABOVE GROUND SERVICES
4a Surface water carrying services
i) Crack and • No visible damage Visual
Damage
-B 3-