POSO ENERGY
QUALITY CONTROL DEPARTMENT DIMENSION INSPECTION REPORT
SKETCH / DRAWING :
Difference (+/-)
Difference (+/-)
Rev : 03
Form No. 001/PESP/QAQC/2018
------------------------------------------------------- --------------------------------------------------
Date : Date : Date :
Project : POSO I HEPP S.1 & REGULATING DAM Report No. : /QC-PE/ /WIR/2016 Rev. 0
Location : Drawing No. : Rev.
W P S No. : P Q R No. : Rev.
Applicable : ASME CODE SEC.V.ART. 9, AWS D1.1 & Owner Technical
Description : Code &
Standard . Specification
Welder : Temperature : °C
Material Spec. : To
Material Thickness : mm To : mm Groove/Fillet :
Angle
Material Diameter : Inch / mm
Surface Condition : Clean Grinding Other ( )
Stage of Exam : After Welding After Repair Other ( )
Joint Design : Groove Fillet Other ( )
Type of Joint : Butt Lap Other ( )
Welding Process : SMAW SAW Other ( )
Welding Current : AC DC EP DC EN
Position : Flat Vertical Horizontal Overhead
Electrode Class/AWS : Diameter : mm
Electrode Shielding : None Fluks (……........) Gas (………..……) Other (...............................)
Heat Treatment : Preheat (…….…°) Interpass Temp (…..........…….°) PWHT (…...…......°)
Current* : ...............................Ampere Voltage* : .......................Volt Welding Speed* : .............................mm/s
Pass / Layer : Single Multi Pass ( ………...... Layer)
Technique : String Weave Intermitten Other ( )
Interpass Cleaning : Grinding Wire Brushing Chipping Other ( )
SKETCH / Drawing :
Rev : 00
Project : PLTA POSO PEAKER 515 MW Report No. : /QC-PE/ /MT/2018 Rev. 0
Poso Extension Stage-1 HEPP (4x30)
Location : Drawing No. : Rev.
Workshop Penstock
Description Procedure No. : Rev.
:
Applicable Code : ASME Code Sec.V.ART.7 & Owner Tech Spec.
Lighting Equipment : Acceptance Criteria : ASME Code Sec.VIII.App.6 & B31.1 Power Piping
Light Meter Type : S.N. : Light Intensity : Lux
Material :
Stage of Examination : After Welding After Hydrostatic After Repair Other ( )
Surface Condition : As Welded Ground Flush Other ( )
Welding Process : SMAW GTAW Other ( )
MT Equipment : Yoke Prods Other ( )
Type of Current : AC HW DC/HW AC Other ( )
Type of Particles : ……………………. Dry Wet
Method : Continuous Residual Other ( )
Project : PLTA POSO PEAKER 515 MW Report No. : /QC-PE/ /PT/2018 Rev. 0
Corrective Action :
Disposition Result
Responsible Manager / Supervisor
Use as-is Return to Supplier
Repair Reject
Rework
Name :
Date :
Critical NC
Name : Name :
Form No. 006/PESP/QAQC/2016
Date : Date :
Closure of / Note :
SPECIMEN DATA
MATERIAL : ITEM INSPECTED / AREA :
MATERIAL THICKNESS : mm To mm DRAWING NO. :
TESTING TEMPERATURE : WELDING PROCESS : SMAW / SAW / FCAW / GMAW/ ………..
SURFACE CONDITION : JOINT DETAILS :
EQUIPMENT PROBES
ULTRASONIC UNIT : TUD290 ANGLE SIZE FREQUENCY REFERENCE DATA TEST RANGE
SC/TC S/NO
SERIAL NO. : 37829000001/3786000001 (mm) MHz SETTING (dB) HOLE Ampl.
CABLE TYPE & LENGTH : & 1500mm
00
COUPLANT : CMC
CALIBRATION BLOCK : V1 & V2
450
REFERENCE BLOCK : BCB
CALIBRATION : 100 mm Test Range
600
SENSITIVITY : 80% FSH + 6 dB + T.O.L
TRANSFER LOSS : 2 dB
700
SCANNING TECHNIQUE : Contact Testing
SIZING TECHNIQUE
LENGTH : 6 dB Drop
HEIGHT (WIDTH) : 20 dB Drop
NOTCH :
Discontinuity Type
Frequency (MHz)
Transfer Of Loses
Type of Probe
Length (mm)
DESCRIPTION
Depth (mm)
Thickness
Accepted
Rejected
PART :
Rev. 03