S.N. Description L.H.S. R.H.S. Remark

1 GPS Coordinate @Structure center 34°24'42.90"


73°58'42.87"

2 Type of Culvert: Slab/ Box/ Arch SLAB SLAB

3 Number of Spans 1 1

Span Arrangement (No. x W x H) (m)


4 1X1.5 1X1.5
(Clear)
Span Arrangement (No. x W x H) (m)
5 1X1.5X1.5 1X1.5
(Exp. - Exp. Joint)
Span Arrangement (No. x a x b) (m)
6 NA NA
(for RCC Box)

7 Thickness of Slab or Rib (for Arch) (m) 0.2 0.2

8 d / e / f / g (for RCC Box) (m) NA NA

Pier Thickness (Top) NA NA


9
Pier Thickness (Bottom) NA NA

10 Wearing Coat type & thickness (mm) Bitumen coat

11 Skew Angle (Straight / Inclined Width) No

12 Direction of Flow Right to left

13 Width of Culvert (Old + New) 0 8.5

14 Carriageway Width (m) 7

15 Inner Width from Parapet to Parapet(m) Parapet do not exist

16 Total Outer Width 8.5

17 Horizontal Curve / Vertical Gradient Exist

Height/ Length/ Thickness of Parapet or


18 Not exist Not exist
Railling (m)
Height/ Length/ Thickness of Crash
19 Not exist Not exist
Barrier (m)

20 Parapet Top to GL (m) Not exist Not exist

Vertical Clearance (GL to Soffit of Slab/


21 1.3 Chocked
Box/ Arch)

22 Details of Approach Slab (if any) Not exist Not exist


22 Details of Approach Slab (if any) Not exist Not exist

Details of Return/ Wing/ Retaining Wall


23 Retaining Wall Chocked
(if any)

24 Material of Slab/ Box/ Arch RCC RCC

25 Material of Pier / Abutment CRSM Chocked

26 Material of Parapet Not exist Not exist


Material of Return/ Wing/ Retaining
27 CRSM Not exist
Wall (if any)

28 Fill over Structures (For Arch) NA NA

29 Condition & Details of Protection Works NA NA

30 Condition & Details of Drainage System Not exist Not exist

31 Condition & Details of Weep Holes Exist Exist

32 Condition of Slab/ Box/ Arch Fair Fair

33 Condition of Pier / Abutment Fair Chocked

Condition of Return/ Wing/ Retaining


34 Fair Chocked
Wall

35 Condition of Parapet Not exist Not exist

36 Details of Vegetation Growth No No

37 Whether Choked No Choked

38 Details & Condition of pitching (if any) Not found Not found

Details of any Scour on Upstream or


39 Not observed Not observed
Downstream

40 Stream Characteristics Not defined Not defined

41 Adequacy of Waterway Adequate Inadequate