INVENTORY AND CONDITION SURVEY FOR ARCH/ SLAB/ BOX CULVERTS
(NH 220)
Project Name : NH No :NH-220
701 Date : Nov 2018
Location (Km) Culverts Design CH: -----------
Proposal as per I & C Survey :Reconstruction Purpose of Culvert :Cross drainage
(Functional Requirement)
S.N. Description L.H.S. R.H.S. Remark
1 GPS Coordinate @Structure center 34°24'42.90"
73°58'42.87"
2 Type of Culvert: Slab/ Box/ Arch SLAB SLAB
3 Number of Spans 1 1
Span Arrangement (No. x W x H) (m)
4 1X1.5 1X1.5 (Clear) Span Arrangement (No. x W x H) (m) 5 1X1.5X1.5 1X1.5 (Exp. - Exp. Joint) Span Arrangement (No. x a x b) (m) 6 NA NA (for RCC Box)
7 Thickness of Slab or Rib (for Arch) (m) 0.2 0.2
8 d / e / f / g (for RCC Box) (m) NA NA
Pier Thickness (Top) NA NA
9 Pier Thickness (Bottom) NA NA
10 Wearing Coat type & thickness (mm) Bitumen coat
11 Skew Angle (Straight / Inclined Width) No
12 Direction of Flow Right to left
13 Width of Culvert (Old + New) 0 8.5
14 Carriageway Width (m) 7
15 Inner Width from Parapet to Parapet(m) Parapet do not exist
16 Total Outer Width 8.5
17 Horizontal Curve / Vertical Gradient Exist
Height/ Length/ Thickness of Parapet or
18 Not exist Not exist Railling (m) Height/ Length/ Thickness of Crash 19 Not exist Not exist Barrier (m)
20 Parapet Top to GL (m) Not exist Not exist
Vertical Clearance (GL to Soffit of Slab/
21 1.3 Chocked Box/ Arch)
22 Details of Approach Slab (if any) Not exist Not exist
22 Details of Approach Slab (if any) Not exist Not exist
Details of Return/ Wing/ Retaining Wall
23 Retaining Wall Chocked (if any)
24 Material of Slab/ Box/ Arch RCC RCC
25 Material of Pier / Abutment CRSM Chocked
26 Material of Parapet Not exist Not exist
Material of Return/ Wing/ Retaining 27 CRSM Not exist Wall (if any)
28 Fill over Structures (For Arch) NA NA
29 Condition & Details of Protection Works NA NA
30 Condition & Details of Drainage System Not exist Not exist
31 Condition & Details of Weep Holes Exist Exist
32 Condition of Slab/ Box/ Arch Fair Fair
33 Condition of Pier / Abutment Fair Chocked
Condition of Return/ Wing/ Retaining
34 Fair Chocked Wall
35 Condition of Parapet Not exist Not exist
36 Details of Vegetation Growth No No
37 Whether Choked No Choked
38 Details & Condition of pitching (if any) Not found Not found
Details of any Scour on Upstream or
39 Not observed Not observed Downstream
40 Stream Characteristics Not defined Not defined
41 Adequacy of Waterway Adequate Inadequate
Remarks (additional feature details if
42 any)
Photographs For All Necessary Details Of Slab/Box/Arch Culvert