Professional Documents
Culture Documents
[1]
Anaya J., [1]Cogollo G., [1]Hernández L., [1]Mendoza Y., [1]Mieles M.
[2]
Correa R.
[1]
Estudiantes de IX semestre de Ingeniería Civil de la Universidad de Cartagena, laboratorio de
Saneamiento
[2]
Docente del laboratorio de Saneamiento ambiental
Cartagena de Indias D. T. y C., septiembre 19 de 2018
RESUMEN:
Mediante de la realización de la presente práctica, se buscaba determinar la concentración de ion
cloruro, mediante valoración colorimétrica, en muestras de agua previamente adicionadas con sulfato
de Aluminio en distintas concentraciones; para ello se tomaron 25 ml de agua depositados en un
matraz Erlenmeyer, a la cual se le agregaron compuestos como Difenil Carbazona, Ácido Nítrico y
Nitrato de Mercurio hasta obtener tonalidades Violeta y Amarillo claro; se anotaron los volúmenes
de sustancia requerido para los cambios de tonalidad. El proceso se repitió para muestras siete
muestras, una muestra de agua únicamente y seis muestras de agua con concentraciones de sulfato de
aluminio expresadas en PPM de: (15), (20), (25), (30), (35), (40). Para la muestra de agua sin Sulfato
de Aluminio y para las muestras con Sulfato de Aluminio, las respectivas concentraciones de ion
cloruro halladas expresadas en PPM, fueron de: (19.99) y (13.99), (13.99), (15.99), (15.99), (13.99),
(13.99).
PALABRAS CLAVES: Ion Cloruro, Valoración Colorimétrica.
ABSTRAC:
By means of the realization of the present practice, it was sought to determine the concentration of
chloride ion using colorimetric titration in samples of water previously added with Aluminum
sulphate in different concentrations; For this, 25 ml of water were taken in an Erlenmeyer flask, to
which compounds such as Diphenyl Carbazone, Nitric Acid and Mercury Nitrate were added until
obtaining Violet and Light Yellow tones; the volumes of substance required for tonality changes were
recorded. The process was repeated for samples seven samples, a water sample only and six water
samples with concentrations of aluminum sulphate expressed in PPM of: (15), (20), (25), (30), (35),
(40) For the sample of water without Aluminum Sulphate and for the samples with Aluminum
Sulphate, the respective concentrations of chloride ion found expressed in PPM, were: (19.99) and
(13.99), (13.99), (15.99), (15.99) ), (13.99), (13.99).
7. BIBLIOGRAFÍAS
Aguilar Romo, M. (2001). Análisis De Agua-
Determinación De Cloruros Totales En
Aguas Naturales, Residuales Y
Residuales Tratadas-Método De Prueba
(Cancela a La Nmx-Aa-073-1981), 159.
Retrieved from
http://www.aniq.org.mx/pqta/pdf/NMX-
AA-quimicosgpo2.pdf
Enciclonet. (n.d.). Nitrato de mercurio.