You are on page 1of 6

REPUBLIC OF THE

PHILIPPINES
TABLE OF CONTENTS DEPARTMENT OF PUBLIC WORKS TRANSPORTATION AND
COMMUNICATION
OFFICE OF THE BUILDING OFFICIAL

PERSPECTIVE
1 2 A1 VICINITY MAP
SITE DEVELOPMENT PLAN
DISTRICT CITY MUNICIPALITY

LAND USE & ZONING

3500 FLOOR PLANS


DOORS & WINDOW
SCHEDULE
A A2 SECTIONS
ELEVATIONS

LINE & GRADE


FOUNDATION PLAN
SECOND FLOOR FRAMING PLAN

3000
THIRD FLOOR FRAMING PLAN
ROOF FRAMING PLAN
S1 CANTILEVER FOOTING DETAIL
WALL FOOTING DETAIL

B CONCRETE BEAM DETAIL ARCHITECTURAL


TWO WAY SLAB DETAIL
CB DETAIL

7500
S2 CONCRETE COLUMN DETAIL
ONE WAY SLAB DETAIL
STAIR DETAIL

LIGHTING LAYOUT

4500
C POWER LAYOUT

E1 RISER DIAGRAM STRUCTURAL


SCHEDULE OF LOADS
1 PERSPECTIVE GENERAL NOTES
A 1 SCALE NTS VICINITY MAPS

WATER LINE
SEWER LINE
P1 ISOMETRIC DIAGRAM
DETAIL OF WATER METER SANITARY
DETAIL OF CATCH BASIN

ELECTRICAL

3 SITE DEVELOPMENT PLAN


A 1 SCALE 1:50 MTS

MECHANICAL

2 VICINITY MAP
A 1 SCALE NTS

ARCHITECT: ENGINEER: PROJECT TITLE: OWNER SHEET CONTENT:

RON JEREMY QUE CRUZ


PROPOSED 3 STOREY RESIDENTIAL BUILDING
MR. ACE MOSEES LIBAO TAYAG
PERSPECTIVE
A
PRC NO: 0035450 PRC NO: MS. MARIA CLEOFE DE JOSE TAYAG VICINITY MAP
PTR NO.: 2880099
VALIDITY: 08/04/2021
DATE ISSUED: 01/19/2018 PTR NO.:
VALIDITY:
DATE ISSUED:
MR. CANDACE GABRIELLE TAYAG
SITE DEVELOPMENT PLAN 1
PLACE ISSUED: MAKATI CITY TIN NO.: 473-249-822-000 PLACE ISSUED: TIN NO.: LOCATION: 11 LUNA ST. BANGKULASI NAVOTAS CITY
TOP

400
FIRE WALL

SMOOTH CEMENT
PLASTER
PAINTED FINISH

3000
1 2 1 2 1 2
CONCRETE
MOLDINGS
3500 3500 3500
THIRD
FLR. LINE
1075 925 1500 2000 1500 1075 975 1450 ACCENT WALL
IN DECORATIVE
8 8 8 STONE FINISH

9500
3000
A2 A2 A2
6" CHB FIREWALL IN
A A A SMOOTH CEMENT

650
700

1350
PLASTER FINISH
1600

W W

3000

3000
1 1 SECOND

2000

2350
FLR. LINE

1600
1400

DN DN BEDROOM
D UP UP D
1

3000
2 3 SMOOTH CEMENT
D D PLASTER

6500

6500
B 9 1 B 9 D B 9 3
A2 W W A2 2 A2 PAINTED FINISH
7500

1 2
2300

2500
LIVING AREA GROUND

100
3800
FLR. LINE

3550

3500
NAT.GRADE
SECONDARY MASTER
LINE
C CARPORT C FIRE EXIT D C BEDROOM
1
FRONT ELEVATION RIGHT SIDE ELEVATION

1000
W SECONDARY 4 5
BALCONY
2200

3
FIRE EXIT A 3 SCALE 1 :100 MTS A 3 SCALE 1 :100 MTS
W W
4 4

TOP

400
FIRE WALL

3500 3500
3500

3000
1 GROUND FLOOR PLAN 2 SECOND FLOOR PLAN 3 THIRD FLOOR PLAN THIRD
A 2 SCALE 1 :100 MTS A 2 SCALE 1 :100 MTS A 2 SCALE 1 :100 MTS FLR. LINE
6" CHB FIREWALL IN 6" CHB FIREWALL IN
SMOOTH CEMENT SMOOTH CEMENT

9500

3000
PLASTER FINISH PLASTER FINISH

1000 700 9000


SECOND
FLR. LINE

3000
2150

2150

2150

GROUND

100
FLR. LINE
NAT.GRADE
LINE

D
1
D
2
D
3 7 LEFT SIDE ELEVATION 6 REAR ELEVATION
A 3 SCALE 1 :100 MTS A 3 SCALE 1 :100 MTS
SOLID WOOD MAIN PANEL DOOR
ENTRANCE DOOR PVC DOOR @ BEDROOMS & EXIT DOOR
TOP

400
FIRE WALL
SMOOTH CEMENT
1000 PLASTER
PAINTED FINISH
600 600

3000
500 500 600 SMOOTH CEMENT
PLASTER
PAINTED FINISH

MASTER BEDROOM
THIRD
FLR. LINE

9500

3000
LIVING AREA
SECOND
W W W W FLR. LINE
1 2 3 4

10MM. THK.CLEAR 10MM. THK.CLEAR 10MM. THK.CLEAR 10MM. THK.CLEAR

3000
GLASS AWNING WINDOW GLASS SLIDING WINDOW GLASS SLIDING WINDOW GLASS SLIDING AWNING WINDOW
ALUMINUM STEEL FRAMING ALUMINUM STEEL FRAMING ALUMINUM STEEL FRAMING ALUMINUM STEEL FRAMING
PAINTED FINISH PAINTED FINISH PAINTED FINISH PAINTED FINISH
GROUND
CARPORT

100
FLR. LINE

10 SCHEDULE OF DOORS & WINDOWS NAT.GRADE


LINE

A 3 1 :50 MTS 8 LONGITUDINAL SECTION 9 CROSS SECTION


A 3 SCALE 1 :100 MTS A 3 SCALE 1 :100 MTS

ARCHITECT: ENGINEER: PROJECT TITLE: OWNER SHEET CONTENT:

RON JEREMY QUE CRUZ


PROPOSED 3 STOREY RESIDENTIAL BUILDING
MR. ACE MOSEES LIBAO TAYAG FLOOR PLAN
ELEVATION
A
PRC NO: 0035450 PRC NO: MS. MARIA CLEOFE DE JOSE TAYAG
PTR NO.: 2880099
VALIDITY: 08/04/2021
DATE ISSUED: 01/19/2018 PTR NO.:
VALIDITY:
DATE ISSUED:
MR. CANDACE GABRIELLE TAYAG
SECTION
SCHEDULE OF DOORS & WINDOWS 2
PLACE ISSUED: MAKATI CITY TIN NO.: 473-249-822-000 PLACE ISSUED: TIN NO.: LOCATION: 11 LUNA ST. BANGKULASI NAVOTAS CITY
2ws 2ws open 2ws open GENERAL NOTES:
b
i
LEGEND & SYMBOLS 1. ALL ELECTRICAL WORKS SHALL BE DONE IN ACCORDANCE WITH THE PROVISIONS OF THE
2ws Sm LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE, THE LAWS AND ORDINANCES
S e S 2ws DN DN
m
UP
a S 2ws UP j CIRCUIT HOMERUN OF THE LOCAL CODE ENFORCING AUTHORITIES AND THE REQUIREMENTS OF THE LOCAL
e 2ws Si Sj
S fg POWER COMPANY.
S cd S ab LIGHTING /POWER LINE 2. THE CONTRACTOR SHALL SECURE ALL PERMITS AND PAY ALL FEES REQUIRED FOR THE
S kl
f g k WORK AND SHALL FURNISH THE OWNER THROUGH THE ENGINEERS. FINAL CERTIFICATES
c S SWITCH OF ELECTRICAL INSPECTION AND APPROVAL FROM PROPER GOVERNMENT AUTHORITIES
FOR COMPLETE WORK.
SERVICE ENTRANCE
d Sh l 3. ALL MATERIALS TO BE USED SHALL BE NEW AND INSTALLED IN APPLICATIONS FOR
h FOR WHICH THEY ARE INTENDED.
M KW/HR METER
1
PB 1 4. LIGHTING AND POWER BRANCH CIRCUIT WITHOUT DESIGNATION SHALL BE REFERRED
1
1 LIGHTING OUTLET TO SIZE AS INDICATED IN THE PANELBOARD SCHEDULE.
PB 1
PB 1
5. BOXES SHALL BE MADE OF CODE GAGE # 16 STEEL WITH ZINC CHROMATE PROTECTION
CONVENIENCE OUTLET
6. MOUNTING HEIGHTS FOR SWITCHES AND CONVENIENCE OUTLETS SHALL BE 1.37M. AND
R RANGE OUTLET 0.30M RESPECTIVELY, UNLESS OTHERWISE INDICATED IN ARCHITECTURAL PLANS.

WP WEATHERPROOF OUTLET 7. ALL RECEPTACLE OUTLETS SHALL BE PROPERLY GROUNDED TO THE BOX BY MEANS OF
GROUND FLOOR SECOND FLOOR THIRD FLOOR GROUNDING LUGS.
1 LIGHTING LAYOUT 2 LIGHTING LAYOUT 3 LIGHTING LAYOUT EXHAUST FAN 8. CONFIRM W/THE ARCHITECTS THE TYPE AND COLOR RENDERING
E 1 SCALE 1 :100 MTS E 1 SCALE 1 :100 MTS E 1 SCALE 1 :100 MTS INDEX OF LIGHTING FIXTURES BEFORE INSTALLATION.
PANEL BOX 9. VERIFY ARCHITECTURAL DRAWINGS FOR LIGHTING FIXTRURES AND WIRING
DEVICES' EXACT LOCATION AND MOUNTING HEIGHTS.
3
PB 1
SAFETY SWITCH 10. FLUORESCENT LIGHTING FIXTURE BALLAST SHALL BE ELECTRONIC TYPE.
open open
11. SPECIAL PURPOSE OUTLET SHALL BE FITTED TO THE EQUIPMENT TO BE PLUGGED-IN.
acu ELECTRICAL CONTRACTOR TO VERIFY AT SITE THE EXISTING CONFIGURATION OF OUTLETS
(TANDEM OR PARALLEL SLOT,ETC..) AND FOR THE NEW EQUIPMENT COORDINATE WITH
DN DN EQUIPMENT SUPPLIER PRIOR TO PROCUREMENT.
UP UP 2
PB 1
12. ALL OUTLETS INSIDE COMFORT ROOM AND BESIDE THE LAVATORY SHALL BE
PROVIDED WITH GROUND FAULT CIRCUIT INTERRUPTER (GFCI).

2
13. REFER TO ELECTRICAL TECHNICAL SPECIFICATIONS FOR FURTHER INSTRUCTIONS.
PB 1
WP
2
PB 1

acu
4
PB 1

GROUND FLOOR SECOND FLOOR THIRD FLOOR


4 LIGHTING LAYOUT 5 LIGHTING LAYOUT 6 LIGHTING LAYOUT
E 1 SCALE 1 :100 MTS E 1 SCALE 1 :100 MTS E 1 SCALE 1 :100 MTS

SCHEDULE OF LOADS AND COMPUTATION MBP1


LOAD
CIRCUIT NO. L.O. C.O. OTHER TOTAL NO. & WATTAGE VOLT, AMPERE VOLTS AMPERES BREAKER RATING SIZE OF WIRE
DESCRIPTIONS
1 MAIN

2 17 LIGHTING OUTLET 17 X 100 1700 230 7.39 15A


CONVENIENCE
3 10 10 X 200 2000 230 8.69 20A
OUTLET
CONCRETED POST
4 ACU 1 X 1840 1840 230 8.00 20A

5 ACU 1 X 1840 1840 230 8.00 20A

6 SPARE 25A

TOTAL 7380 230 32.08 85 A KILOWATT-HOUR METER M


(BY MERALCO)
APPLY 80% DEMAND FACTOR (0.80 DF) : 32.08 X 0.80 + (25% x 8.00) =27.66 AMPERES

IN 20 mm RSC
MAIN BREAKER: 50 AT, 2P, 230V
B.O. 22 KAIC TO MAIN POWER SUPPLY

GROUND LEVEL

5 RISER DIAGRAM 6 VICINTY MAP


E 1 SCALE NTS
E 1 SCALE NTS

ARCHITECT: ENGINEER: PROJECT TITLE: OWNER SHEET CONTENT:

RON JEREMY QUE CRUZ FERDINAND A. VELASCO


PROPOSED 3 STOREY RESIDENTIAL BUILDING
MR. ACE MOSEES LIBAO TAYAG LIGHTING LAYOUT
POWER LAYOUT
E
PRC NO: 0035450 PRC NO: MS. MARIA CLEOFE DE JOSE TAYAG
PTR NO.: 2880099
VALIDITY: 08/04/2021
DATE ISSUED: 01/19/2018 PTR NO.:
2684 VALIDITY:
DATE ISSUED:
MR. CANDACE GABRIELLE TAYAG
VICINITY MAP
RISER DIAGRAM 1
PLACE ISSUED: MAKATI CITY TIN NO.: 473-249-822-000 PLACE ISSUED: TIN NO.: 117-684-563 LOCATION: 11 LUNA ST. BANGKULASI NAVOTAS CITY
GENERAL NOTES
1. ALL SANITARY WORKS INCLUDED HEREIN SHALL BE EXECUTED ACCORDING TO THE
DS CO DS DS DS PROVISIONS OF THE NATIONAL PLUMBING CODE OF THE PHILIPPINES, THE NATIONAL
CB open open BUILDING CODE OF THE PHILIPPINES, AND IT'S IMPLENTING RULES AND REGULATIONS.
CO FD FD
KS
FD 2. COORDINATE THE DRAWING WITH OTHER RELATED DRAWINGS AND SPECIFICATIONS,
THE ARCHITECT AND/OR THE ENGINEER SHALL BE NOTIFIED IMMEDIATELY OF ANY
CO DISCREPANCY FOUND THEREIN, HIS/HER DECISION SHALL BE FINAL.
FEED FROM DN WC DN
WC
UP
ABOVE
UP 3. ALL PIPES SHALL BE INSTALLED AS INDICATED, ANY RELOCATION REQUIRED FOR PROPER
LAV
FD
FEED FROM EXECUTION OF OTHER TRADES SHALL BE WITH PRIOR APPROVAL OF THE ARCHITECT AND
LAV BELOW
DS CB DS DS DS
FD FD
4. PROPOSED SANITARY UTILITIES SHALL CONFORM TO THE ACTUAL LOCATION, DEPTH AND
INVERT ELEVATION OF EXISTING PIPES AND STRUCTURES AS VERIFIED BY THE CONTRACTOR.
5 DETAIL OF FLOOR DRAIN 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REQUIRED FLOOR AND WALL OPENINGS.
P 1 SCALE 1 :40 MTS
SEPTIC 600 6. ALL SLOPES FOR HORIZONTAL DRAINAGE SHALL MAINTAIN 1% AS MINIMUM, UNLESS
VAULT 100 400 100
FD FD
FD FD
DS DS DS
7. SIZE OF WATER SUPPLY PIPES TO FIXTURES SHALL BE IN ACCORDANCE WITH THE
MANUFACTURER'S INSTRUCTION.
CB 8. ALL FIXTURES SHALL BE VENTED, UNLESS OTHRWISE NOTED.
DS
9. THE WORK THROUGHOUT SHALL BE EXECUTED IN THE BEST AND MOST THROUGH
MANNER KNOWN TO THE TRADE AND TO THE SATISFACTION OF THE ARCHITECT AND/OR
THE ENGINEER.
TO MAIN SEWER
10. THE CONTRACTOR SHALL VERIFY ALL EXISTING UTILITIES AT SITE AND COORDINATE THE
GROUND FLOOR SECOND FLOOR THIRD FLOOR THIRD FLOOR WITH THE SEWER EFFLUENT DISPOSAL AND WATER LINE SERVICE CONNECTING POINT.
1 SEWER LINE LAYOUT 2 SEWER LINE LAYOUT 3 SEWER LINE LAYOUT 4 SEWER LINE LAYOUT 11. REFER TO TECHNICAL SPECIFICATIONS FOR DETAILED MATERIAL AND EQUIPMENT
P 1 SCALE 1 :100 MTS P 1 SCALE 1 :100 MTS P 1 SCALE 1 :100 MTS P 1 SCALE 1 :100 MTS SPECIFICATIONS.
PLAN
12. PIPING MAY'L SHALL BE S-BLUE OR EQUIVALENT BUT NOT G.I. PIPE.

GV open LEGEND & SYMBOLS


F CV
FD FLOOR DRAIN KS KITCHEN SINK
SHO
DW DROP DOWN F FAUCET
DN WC WC WATER CLOSET CO CLEAN OUT
WC UP UP
F
GV F LAV LAVATORY DS DOWN SPOUT
CV GV CV
SV SEPTIC VAULT M WATER METER
FEED FROM FEED FROM
ABOVE BELOW CB CATCH BASIN VTR VENT THRU ROOF
SECTION SEWER LINE WATER LINE
ELEVATION
4.00

2.00 1.00 1.00

10 DETAIL OF CATCH BASIN


GV
P 1 SCALE 1 :20 MTS C.O. C.O.
M 4" NELTEX PVC PIPE
INLET AIR SPACE
GV
OUTLET
FROM MAIN WATER SOURCE H2O LINE

GROUND FLOOR SECOND FLOOR


5 SEWER LINE LAYOUT 6 SEWER LINE LAYOUT
P 1 SCALE 1 :100 MTS P 1 SCALE 1 :100 MTS DIGESTION CHAMBER LEACHING CHAMBER

bothways

fine sand over coarse gravel 6" thick CHB.

0.40 0.40 0.40 0.40

4.00

2.00 1.00 1.00

0.15 0.15 0.15

4" NELTEX PVC PIPE

DIGESTION CHAMBER

0.40 m. X 0.40 m. 0.40 m. X 0.40 m. 0.40 m. X 0.40 m.


MANHOLE MANHOLE MANHOLE

LEACHING CHAMBER 1 LEACHING CHAMBER 2

SEWER LINE WATER LINE


9 VICINTY MAP 7 ISOMETRIC DIAGRAM 8 ISOMETRIC DIAGRAM 11 DETAIL OF SEPTIC TANK
P 1 SCALE NTS P 1 SCALE 1 :100 MTS P 1 SCALE 1 :100 MTS
P 1 SCALE NTS

ARCHITECT: ENGINEER: PROJECT TITLE: OWNER SHEET CONTENT:

RON JEREMY QUE CRUZ AUGUSTO SAMONTE PONGE


PROPOSED 3 STOREY RESIDENTIAL BUILDING
MR. ACE MOSEES LIBAO TAYAG ISOMETRIC DIAGRAM
SEWER LAYOUT P
PRC NO: 0035450 PRC NO: MS. MARIA CLEOFE DE JOSE TAYAG WATER LINE LAYOUT

PTR NO.: 2880099


VALIDITY: 08/04/2021
DATE ISSUED: 01/19/2018 PTR NO.:
0128010
7907676
VALIDITY: 08-31-2021
DATE ISSUED: 01-26-2018
MR. CANDACE GABRIELLE TAYAG
VICINITY MAP
DETAIL OF CATCH BASIN
DETAIL OF SEPTIC TANK
1
PLACE ISSUED: MAKATI CITY TIN NO.: 473-249-822-000 PLACE ISSUED: OLONGAPO CITY TIN NO.: 442-889-519-000 LOCATION: 11 LUNA ST. BANGKULASI NAVOTAS CITY
1 2 1 2

3500

3500 2100 1400

A A

650
FTB C-1 B2openC-1

1925
STAIRWELL B3

3000

3000
C-1 F-1 C-1 F-1 B1

2350
B2

FTB

FTB
SLAB ON FILL B1
DN B3 S-01

1075
UP B1 S-01
UP

B B
FTB C-1 B1 C-1

7500

7500

7500

7500
C-1 F-1 C-1 F-1

2500

2500

2500

2500
FTB

FTB
SLAB ON FILL S-02
B1 B1
C-1 F-1 C-1 F-1
B1
C C
FTB C-1 C-1

1000

1000
B2 S-02 B2
2000

2000

1000

1000
B2

3500 5 DETAIL OF CANTILEVER FOOTING


S 1 SCALE NTS
3500

1 FOUNDATION PLAN 2 SECOND FLOOR FRAMING PLAN


S 1 SCALE 1:150 MTRS S 1 SCALE 1:150 MTRS

1 2 1 2

3500

2100 1400 3500

FFL
A A
650

C-1 B2openC-1 C-1 B1 openC-1


1350

STAIRWELL B3
B3 NGL
3000

3000
B1
575

B1 S-02 B1
2350

B3 S-01 B2 B1
DN B3 S-01 DN
1075

B1 S-01

B B
C-1 B1 C-1 C-1 B1 C-1
7500

7500

7500

7500
2500

2500

2500

2500
S-02 S-02
B1 B1 B1 B1

B1 B1
C C
C-1 C-1 C-1 C-1
1000

1000

1000

1000

B2 S-01 B2 B2 S-01 B2
B2 B2
@ 300 O.C.
1000

1000

1000

1000

3500 3500 6 WALL FOOTING DETAILS


S 1 SCALE NTS

3 THIRD FLOOR FRAMING PLAN 4 ROOF FRAMING PLAN


S 1 SCALE 1:150 MTRS S 1 SCALE 1:150 MTRS

ARCHITECT: ENGINEER: PROJECT TITLE: OWNER: SHEET CONTENT:

RON JEREMY QUE CRUZ ENGR. AUGUSTO SAMONTE PONGE


PROPOSED 3 STOREY RESIDENTIAL BUILDING
MR. ACE MOSEES LIBAO TAYAG
FOUNDATION PLAN
SECOND FLOOR FRAMING PLAN
THIRD FLOOR FRAMING PLAN
S
PRC NO: 0035450 PRC NO: MS. MARIA CLEOFE DE JOSE TAYAG
PTR NO.: 2880099
VALIDITY: 08/04/2021
DATE ISSUED: 01/19/2018 PTR NO.:
0128010
7907676
VALIDITY: 08-31-2021
DATE ISSUED: 01-26-2018
MR. CANDACE GABRIELLE TAYAG
ROOF FRAMING PLAN
CANTILEVER FOOTING DETAIL
WALL FOOTING DETAIL
1
PLACE ISSUED: MAKATI CITY TIN NO.: 473-249-822-000 PLACE ISSUED: OLONGAPO CITY TIN NO.: 442-889-519-000 LOCATION: 11 LUNA ST. BANGKULASI NAVOTAS CITY
250 250

350

350
200 200

400

400
150 150

300

300
1 CONCRETE BEAM DETAIL 2 TWO WAY SLAB DETAIL
S 2 SCALE NTS S 2 SCALE NTS
200

200 250

1 1
0 0
d d

400

350
3 CB DETAIL m
in
m
in
S 2 SCALE NTS . .

4 CONCRETE COLUMN DETAIL


S 2 SCALE NTS

ONE WAY SLAB DETAIL


VAR

5
S 2 SCALE NTS

S-1 125 200 150 ONE WAY

S-2 150 150 150 150 150 150 150 TWO WAY
SLAB ON
FILL 150 400 400 ONE WAY

6 STAIR DETAIL
S 2 SCALE NTS

ARCHITECT: ENGINEER: PROJECT TITLE: OWNER: SHEET CONTENT:

RON JEREMY QUE CRUZ AUGUSTO SAMONTE PONGE


PROPOSED 3 STOREY RESIDENTIAL BUILDING
MR. ACE MOSEES LIBAO TAYAG
CONCRETE BEAM DETAIL
TWO WAY SLAB DETAIL
CB DETAIL
S
PRC NO: 0035450 PRC NO: MS. MARIA CLEOFE DE JOSE TAYAG
PTR NO.: 2880099
VALIDITY: 08/04/2021
DATE ISSUED: 01/19/2018 PTR NO.:
0128010
7907676
VALIDITY: 08-31-2021
DATE ISSUED: 01-26-2018
MR. CANDACE GABRIELLE TAYAG
CONCRETE COLUMN DETAIL
ONE WAY SLAB DETAIL
STAIR DETAIL
2
PLACE ISSUED: MAKATI CITY TIN NO.: 473-249-822-000 PLACE ISSUED: OLONGAPO CITY TIN NO.: 442-889-519-000 LOCATION: 11 LUNA ST. BANGKULASI NAVOTAS CITY