You are on page 1of 1

SCOPE and breaker fail with single, dual, Rail catenary protection

The P40 range fulfills the requirements breaker and a half and mesh circuit P44T - Subcycle distance protection
at all voltage levels from MV to breaker topologies
EHV/UHV for industrial, distribution, PROTECTION AND CONTROL
generation, rail and transmission Substation plant protection FEATURES
systems. Applicable at all voltage levels, to Protection elements
safeguard the most costly system All algorithm and hardware know-how
COMMON FEATURES assets: is the culmination of decades of
• 1 A/5 A dual rated CTs for simplified P64* - Transformer management advances in Alstom’s centres of
inventories and protection, for between two and
five-ended schemes excellence. The platform has vast
• Event and disturbance recording for experience in test and in-service
post-fault analysis P74* - Numerical busbar protection
(biased principle) suitable for operational environments, proving the
• Rear ports with choice of protocols,
and front port for local setting application on MV, HV and EHV technical integrity.
• Full programmable scheme logic for busbars
customer-specific automation P14* - Numerical high-impedance The comprehensive and advanced
• Scalable input / output hardware busbar and REF protection schemes, library of protection and control
depending on requirements deployed with varistors functions in each device allow it to
• Operating voltage user programmable meet the exact application
for opto inputs Rotating machine protection
Specialist devices for protection, control requirements. Multiple protection
• Hardware accessories available for
and monitoring of all machine types functions, logic and control functions
easy mounting in racks or panels
and ratings: may be enabled, without deterioration
APPLICATIONS P24* - Rotating machine in performance – the platform is fully
Feeder protection management relay for application deterministic.
A full range, with directional and non- on a wide range of synchronous and
directional applications of overcurrent induction machines INDEPENDENT PROTECTION
and earth fault at its heart: P34* - Generator protection for SETTINGS GROUPS
• P14x - Feeder management relay small to sophisticated generator
The 40 series can offer up to four
suitable for MV systems and HV systems, and interconnection
protection independent settings groups. These can
system backup, with autoreclose, and be activated locally, remotely or via a
check synchronism within the model
System monitoring and stability dedicated input and are used to allow
option selection
• P341 - Grid interconnection devices for different system operating
protection, at the point of coupling Fast-acting devices to take local conditions and where adaptive relaying
systems with embedded generation decisions and input to wide area is applied.
schemes:
Line protection P14* - Voltage and frequency
A full range extending up to the most protection for load shedding, load
demanding sub-cycle technology for restoration and generator abnormal
EHV and UHV transmission: detection
• P44* - Full scheme distance P84* - System stability devices,
protection relays for HV, EHV and including a P847 Phasor
UHV systems Measurement Unit (PMU) for all
• P54* - Line differential protection grid applications
relays for direct fibre and multiplexed
communication options as well as n
phase comparison protection for use
with power line carrier
• P84* - Transmission line terminal
devices for backup, reclose

You might also like