WAIVER LIST 888 BRICKELL PLAZA, MIAMI, FLORIDA 33131 folio # 01-0205-050-1010
folio # 01-0205-050-1110
Waiver # 1 - (see sheet A-021) folio # 01-0205-050-1120
D
Waiver pursuant to section 7.1.2.5 (a) (28) of MIAMI 21 to permit up to a 10% Gross Lot Area
Net Lot Area
34,810
33,719
0.80
0.77
5,000 SF
D
increase to Lot Coverage of 80% revuelta
Legal Description
architecture
Waiver # 2 - (see sheet A-005) Refer to Survey international
Flood Elevation
Parking Reduction up to 30% This property appears to be located in Flood Zone AE 9 as per Federal Emergency Management Agency (FEMA) Panel #12086C-0314L
Waiver pursuant to Article 4, Table 4 of MIAMI 21 for up to a 30% Parking Zoning Classification Santiago, Chile
Miami
Reduction for properties located within a T.O.D. or Transit Corridor. T6- 48b-O
FLR Lot Area Multiplier Allowable Proposed revuelta.com
Industrial Loading Berth with 2 (two) Commercial Loading Berths. Principal Frontage (SW 8th street)
Secondary Frontage (SW 1st Avenue)
0'-0"
0'-0"
10'-0"
10'-0"
Side Setback 0'-0" 0'-0"
Waiver # 4 - (see sheets A-030 & A-031)
parking to extend into the second layer beyond 50% of the length of the Total Allowable Building Height 80 50
NOTES: Refer to A-502 for Stories Diagram. Per Miami 21 Section 3.5 Measurement of Height Section 3.5.2 in T6-48 floor levels exceeding 14' may count as one story if the building does not
frontage along the Secondary Frontage with art treatment. exceed the maximum height, including all applicable bonuses.
20' Setback for lots less than 100' Lot Coverage Net Lot Area Multiplier Allowable Proposed
Waiver pursuant to section 5.6.1 (h) of MIAMI 21 to reduce side and rear 1 to 8 Stories - 80% Maximum
Above 8th Story - 30,000 SF Floorplate Commercial
33,719 0.80 +10% by waiver 29,673 SF
30,000 SF
29,672 SF
20,031 SF
These Design And Drawings Are The Copyrighted Property Of Revuelta Architecture International P.A. and May Not Be Reproduced Except with Specific Written Consent of the Architect.
setbacks to a minimum of 20'-0" for lots having one dimension 100'-0" or less.
Maximum Building Length (Above 8th Story) Allowable Proposed
B Commercial Uses 215 FT 212'-4" B
WATSON
Parking Back-up reduction of 10% Parking Space Requirements
Office
Useable Area (SF)
490,200
Parking Spaces per Use
1 per 800 SF
multiplier
0.00125
Required
612.75
Proposed INVESTIGATIONS LLC.
2525 PONCE DE LEON BLVD.
CORAL GABLES, FLORIDA
Waiver pursuant to Article 7, section 7.1.2.5 (a) 28 of MIAMI 21 that allows for Commercial 14,831 3 per 1000 SF 0.0030 44.49 33134
Design Architect
so promotes the intent of the particular Transect Zone. Total Parking Required with Waiver 460.07 626
Adjustment to the Landscape Requirements Note: Greater than 500,000 SF of Commercial \ Office Use requires One (1) Industrial berth. Article 4, Table 5 allows for the Industrial Berth (660 SF) to be substituted by Two (2) Commercial
Berths (420 SF) by waiver.
Waiver pursuant to section 9.12 of MIAMI 21 for an Adjustment to the Digitally signed
by Luis O.
Bicycle Racks Required Parking Bike Spaces Factor multiplier Required Proposed
Landscape Requirements for required trees at the property. Office \ Commercial - 1 per 20 required parking spaces 460.07 1 per 20 0.050 23 23
Revuelta
Date:
2019.02.12
20:44:49-05'00'
Sustainability Required Proposed
LEED Silver Silver or Better
Luis O. Revuelta
A Notes: A AR-0007972
1.As appropriate to the nature of the Waiver involved and the particular circumstances of the case, Waivers up to ten percent (10%) of any particular standard of this Code except Density,Intensity
and Height, may be granted when doing so promotes the intent of the particularTransect Zone where the proposal is located; is consistent with the guiding principles of this Code; and there is PLANNING & ZONING
practical difficulty in otherwisemeeting the standards of the Transect Zone, or when doing so promotes energy conservation and Building sustainability.
Date
2. (5.6.1.h) For T6-24, t6-36, t6-48, T6-60, and T6-80 Lots having one (1) dimension one hundred (100) feet or less, side and rear setbacks above the 8th floor may be reduced to a minimum of
1/14/2019
twenty (20) feet by Waiver.
Scale
3. (5.6.4.e) Above ground Parking may extend into the second layer beyond 50% of the length of the frontage or height of the pedestal, by Waiver, if an art or glass treatment of a design to be AS SHOWN
approved by the Planning Director is provided for that portion of the pedestal facade. Project No.
1728
1 ZONING DATA
Sheet No.
6 5 4 3 2 1 A-003