ASSUMPTIONS USED FOR ANALYSIS

STRUCTURAL DATA LIVELOAD

Beam Length = 3000 mm


Column Length = 3000 mm
Supports Fixed End
Section HP18X204

Note: SEISMIC LOAD


The section above is used to ensure that the members would carry the assigned loads
Assu

DEADLOAD
Fundamental Time of Vibra
Assume Deadloads to be Selfweight only,Weight of one Beam is Calculated below

Near Source Factor

Seismic Response Coefficie

HP18X204 Data
Seismic Zone Factor
T= 343 mm tw= 28.7 mm
tf= 28.7 mm bf= 460 mm
ɣsteel = 7850 kg/m3
Seismic Importance Factor

Aweb = T x tw Aflange = bf x tf
Aweb = 9844.1 mm2 Aweb = 13202 mm2
0.009844 m2 0.013202 m2 Nmuerical Coefficient R

Vweb = Aweb x L Vflange = Aflange x L


Vweb = 29532300 mm3 Vflange = 39606000 mm3
0.029532 m3 0.039606 m3

Weight in Kg = ɣsteel x 2(Vflange) + ɣsteel(Vweb)


Weight in Kg = 774.56 kg

In KN ( 1 kg = 0.00980665)
Weight in KN = 7.60 kN
ASSUMPTIONS USED FOR ANALYSIS

LIVELOAD

Assume Liveloads to be 4.8 kpa

Floor Liveload = LL X L KN/m


Floor Liveload = 14.4 KN/m

SEISMIC LOAD

Assume Selfweights per floor in solving storeymass


Datas used are listed below:

Fundamental Time of Vibration

CT = 0.0643 (for steel frames)

Near Source Factor

Na = 1.2000 (Type A Seismic Source)


Nv = 1.6000 (Type A Seismic Source)

Seismic Response Coefficients

Ca = 0.44Na (For SD Soil Profile at Seismic Zone 4)


Cv = 0.64Nv (For SD Soil Profile at Seismic Zone 4)

Seismic Zone Factor

Z= 0.4000 (Seismic Zone 4)

Seismic Importance Factor

I= 1.0000 (Standard Occupancy Structures)

Nmuerical Coefficient R

R= 8.5000 (For Special Moment Resisting Frames)