Professional Documents
Culture Documents
www.swagelok.com
REGULATORS
K SERIES
■ Pressure-reducing models
■ Back-pressure models
■ Vaporizing models
2 Pressure Regulators and Filters
Contents
High-Flow High-Pressure
Operation, 3
(KPF Series), 18 (KHB Series), 32
Selection, 3
Testing, 4
Features, 5
High-Pressure
Pressure-Reducing (KHP Series), 20 Specialty Pressure-Reducing
Gas Cylinder
General-Purpose Changeover
(KPR Series), 6 (KCM Series), 34
High-Pressure
Hydraulic
Two-Stage (KHR Series), 22
(KCY Series), 8
Steam-Heated
Vaporizing
(KSV Series), 36
Back-Pressure
High-Sensitivity
(KLF Series), 10 General-Purpose
(KBP Series), 24 Electrically Heated
Vaporizing
(KEV Series), 38
High-Flow,
High-Sensitivity
High-Flow,
(KHF Series), 12
High-Sensitivity
(KFB Series), 26
Compact
(KCP Series), 14
Compact
(KCB Series), 28
Flow Data
REGULATORS
K SERIES
Pressure-Reducing Regulators, 41
Back-Pressure Regulators, 49
Medium- to Medium- to
High-Pressure High-Pressure Port Configurations, 52
(KPP Series), 16 (KPB Series), 30
Options and Accessories, 53
Maintenance Kits, 56
Pressure Regulators—K Series 3
Vaporizing
Vaporizing
Compact,
Electrical
Pressure
psig (bar)
Sensing
Sensing
2 Stage
0 to ....
Steam
Piston
(300)
K SERIES
KSV ✓ ✓ 3600 ✓ ✓ ✓ ✓ ✓ ✓
KEV (248)
✓➀ ✓➀ ✓ ✓ ✓ ✓ ✓ ✓ ✓
Back-Pressure Models
KBP ✓ ✓ ✓ ✓ ✓ ✓ ✓
KFB ✓ Equal to ✓ ✓ ✓ ✓ ✓
pressure
KCB ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
control
KPB ✓ range
KHB ✓ ✓ ✓
➀ Outlet pressures up to 500 psig (34.4 bar) require diaphragm sensing mechanism; outlet pressures above 500 psig (34.4 bar) require piston sensing
mechanism.
4 Pressure Regulators and Filters
Testing
model, it is important to make sure that SPE will not cause Every Swagelok K series pressure regulator is pressure
excessive overpressurization on opening and closing of the tested with nitrogen.
supply pressure.
Back-Pressure Regulators
Cleaning and Packaging
Every Swagelok K series pressure regulator is cleaned and
Back-pressure regulators control inlet pressure by balancing
packaged in accordance with Swagelok Standard Cleaning
an adjustable spring force against the force of the inlet
and Packaging (SC-10) (MS-06-62).
pressure. The spring force is adjusted by turning the stem/
handle, which sets the desired inlet pressure. Cleaning and packaging to ensure compliance with product
cleanliness requirements stated in ASTM G93 Level E is
When the force caused by the inlet pressure rises above the
available for brass and stainless steel Swagelok regulators.
force of the spring, the regulator opens until the spring force
and inlet pressure are balanced again. Cleaning and packaging in accordance with Swagelok
Special Cleaning and Packaging (SC-11) (MS‑06‑63), to
• Swagelok pressure regulators are not “Safety ensure compliance with product cleanliness requirements
Accessories” as defined in the Pressure Equipment stated in ASTM G93 Level C is available for select KPR, KCY,
Directive 2014/68/EU. KCP, KBP, and KCB series regulators.
• Do not use the regulator as a shutoff device.
Oxygen Service Hazards
• Self-venting and captured-venting regulators can For more information about hazards and risks of oxygen-
release system fluid to atmosphere. Position the enriched systems, see the Swagelok Oxygen System Safety
self-vent hole or the captured vent connection away technical report (MS-06-13).
from operating personnel. See Venting Options,
page 5, for more information.
10 to 15 to 25 to 50 to 100 to
0 to .... 1500 2500 3600 6000 10 000
1000 1500 2000 3000 3600 4000 (0.68 to (1.0 to (1.7 to (3.5 to (6.8 to
Flow Coefficient (Cv)
(68.9) (103) (137) (206) (248) (275) 103) 172) 248) 413) 689) 0.02 0.06 0.10 0.20 0.25 0.50 1.0 Page
✓ ✓ ✓ ✓ 6
✓ ✓ ✓ 8
✓ ✓ ✓ ✓ 10
✓ 12
✓ ✓ ✓ ✓ ✓ ✓ 14
✓ ✓ ✓ ✓ ✓ ✓ ✓ 16
✓ ✓ ✓ ✓ ✓ 18
✓ ✓ ✓ ✓ ✓ ✓ ✓ 20
✓ ✓ ✓ ✓ ✓ ✓ ✓ 22
✓ 34
REGULATORS
K SERIES
✓ ✓ 36
✓ ✓ ✓ ✓ ✓ ✓ ✓ 38
✓ 24
✓ 26
✓ ✓ 28
✓ ✓ ✓ ✓ ✓ ✓ 30
✓ ✓ ✓ ✓ ✓ ✓ ✓ 32
Pressure Regulators—K Series 5
Stem
Fine-pitch threads
enable precise spring
adjustment with low torque.
Stop Plate
This disc provides positive Range Spring
backup to the diaphragm in case Turning the handle compresses
of diaphragm overpressure. the spring, pushing the poppet
away from the seat and
increasing outlet pressure.
Convoluted Diaphragm
The all-metal diaphragm acts
as the sensing mechanism
between the inlet pressure Two-Piece Cap
and the range spring. The The two-piece design provides
convoluted, nonperforated linear load on the diaphragm
design ensures greater seal when the cap ring is
sensitivity and longer life. tightened, eliminating torque
A piston sensing mechanism damage to the diaphragm
(shown below) can during assembly.
accommodate higher
pressures.
Inlet Outlet
REGULATORS
K SERIES
General-Purpose Diaphragm-Sensing,
Pressure-Reducing Regulators (KPR Series)
The KPR series is a compact regulator with excellent accuracy, sensitivity, and set-
point pressure stability.
Features Supply-Pressure Effect
■ Convoluted, nonperforated diaphragm
Pressure Control Range
■ Metal-to-metal diaphragm seal Up to 250 psig
■ Low internal volume 100 psig (17.2 bar)
Flow
(6.8 bar) and Higher
■ Two-piece cap design provides linear Coefficient
load on the diaphragm seal (Cv ) Supply Pressure Effect, %
■ High-flow, dual-gauze type filter in 0.02 0.3 0.5
inlet ports 0.06 1.0 1.5
0.20 1.7 2.5
Technical Data 0.50 2.3 3.3
Maximum Inlet Pressure
■ 3600 psig (248 bar) Maximum Operating Temperature Ports
■ 6000 psig (413 bar) with PEEK seat ■ 176°F (80°C) with PCTFE seat ■ 1/4 in. female NPT inlet, outlet, and
Pressure Control Ranges ■ 392°F (200°C) with PEEK seat gauge ports (all body materials)
■ 0 to 10 psig (0.68 bar) through ■ 212°F (100°C) with PEEK seat and ■ 1/4 in. tube butt weld inlet, outlet,
0 to 500 psig (34.4 bar) maximum inlet pressure greater than and gauge ports (316 SS body
3600 psig (248 bar) material only)
Flow Coefficient (Cv )
■ 0.06 and 0.20 Weight ■ 1/4 in. VCR® inlet, outlet, and gauge
ports (316 SS body material only)
See page 41 for flow graphs. ■ 2.4 lb (1.1 kg)
■ 0.02 and 0.50 also available
Alloy
Poppet spring Alloy X-750
Poppet C‑276
Filter damper Poppet damper, filter carrier PTFE
carrier, filter
Self-vent seal➁ Fluorocarbon FKM —
Body Brass Alloy
Body 316 SS Alloy 400
CW721R C‑276
Tube butt weld ports,➁
316L SS —
VCR gland ports➁
Wetted lubricant PTFE-based
Wetted components listed in italics.
➀ Not required in all configurations.
➁ Not shown.
➂ Regulators with control ranges higher than 0 to 100 psig (0 to 6.8 bar) are
assembled with two diaphragms.
Pressure Regulators—K Series 7
Dimensions
Dimensions, in inches (millimeters), are for reference only and are subject to change. Tube Butt
Weld Ports
Female NPT Panel 0.39 (10.0) thick maximum with 2 lock nuts
Ports Panel 0.63 (16.0) thick maximum with 1 lock nut 0.84
Panel cutout 1.38 (35.0) dia (21.3)
3.00
(76.2)
2.13 2.16 0.75 VCR Ports
(54.0) (55.0)
(19.0)
dia dia
0.84
0.75 (21.3)
(19.0)
4.61 Mounting holes 5.00 3.70
(117) 10-32, 0.33 deep (127) (94.0)
(M5 × 0.8, 8.5 deep)
Ordering Information
Build a KPR series regulator ordering number by combining the designators in the sequence shown below.
4 5 6 7 8 9 10 11 12 13 14 15 16
KPR 1 F R F 4 1 2 A 2 0 0 0 0
4 Body Material
7 Port Configuration 12 Handle, Mounting
1 = 316 SS
2 = Brass CW721R A, B, C, E, F, H, K, L, M, N 2 = Knob
4 = Alloy 400 See Port Configurations, page 52. 3 = 316 SS antitamper nut
5 = Alloy C-276 6 = Knob, panel mount
8 Ports 7 = 316 SS antitamper nut, panel mount
A = 316 SS, ASTM G93 Level E-cleaned
B = Brass, ASTM G93 Level E-cleaned 4 = 1/4 in. female NPT For knob handle color options, see
C = 316 SS, SC-11–cleaned T = 1/4 in. × 0.035 in. tube butt weld➀ page 56.
D = Brass, SC-11–cleaned V = 1/4 in. VCR gland, no nuts➀➁
X = 1/4 in. rotatable female VCR fitting➀ 13 Isolation and Relief Valves
5 Pressure Control Range Y = 1/4 in. rotatable male VCR fitting➀ 0 = No valves
C = 0 to 10 psig (0 to 0.68 bar)➀ ➀ Available only with 316 SS body material in A For isolation and relief valve options,
D = 0 to 25 psig (0 to 1.7 bar)➀ and F port configurations; does not contain
E = 0 to 50 psig (0 to 3.4 bar) a filter. Not available with maximum inlet see page 54.
pressure greater than 3600 psig (248 bar). Not
F = 0 to 100 psig (0 to 6.8 bar) available ASTM G93 Level E-cleaned. 14 Cylinder Connections
G = 0 to 250 psig (0 to 17.2 bar) ➁ For use with VCR split-nuts, which can be
J = 0 to 500 psig (0 to 34.4 bar) 0 = No connections
ordered separately. See the Swagelok VCR
➀ Select 0.02 or 0.06 flow coefficient if maximum Metal Gasket Face Seal Fittings catalog For cylinder connection options and
inlet pressure is 4351 psig (300 bar) or (MS‑01-24). pressure ratings, see page 53.
6000 psig (413 bar).
9 Seat Material 15 Gauges
6 Maximum Inlet Pressure➀➁ 1 = PCTFE 0 = No gauges
F = 100 psig (6.8 bar) 2 = PEEK
J = 500 psig (34.4 bar) For inlet and outlet gauge options, see
L = 1000 psig (68.9 bar) 10 Flow Coefficient (Cv) page 54.
P = 3000 psig (206 bar) 1 = 0.02 5 = 0.20
R = 3600 psig (248 bar) 16 Options
2 = 0.06 7 = 0.50
T = 4351 psig (300 bar)➂ 0 = No options
W = 6000 psig (413 bar)➂➃ 11 Sensing Mechanism, Vent H =Inboard helium leak test
➀ For better resolution and control, select a A = Alloy X-750 diaphragm, no vent to a maximum leak rate of REGULATORS
Two-Stage Diaphragm-Sensing,
Pressure-Reducing Regulators (KCY Series)
The KCY series is designed for use in applications requiring constant outlet pressure
even with wide variations in inlet pressure. This two-stage regulator is comparable to two
single-stage regulators connected in series. The first stage is factory set to reduce the
inlet pressure to 500 psig (34.4 bar). The second stage can be adjusted with the handle to
achieve the required outlet pressure.
This two-stage arrangement minimizes the supply-pressure effect caused by fluctuating inlet
pressure, such as with a depleting gas cylinder. As inlet pressure drops below the setting of the
first stage, the regulator then functions as a single-stage regulator. The first-stage pressure setting
can be reduced while monitoring the pressure at the interstage port, but lower flow may result.
poppet springs
K SERIES
Poppets S17400 SS
Inlet Outlet
Poppet dampers,
PTFE
filter carrier
Filter carrier, Body Interstage port plug 316 SS with PTFE tape
filter Self-vent seal➂ Fluorocarbon FKM
Body 316 SS Brass CW721R
Wetted lubricant PTFE-based
1st stage Wetted components listed in italics.
range spring ➀ Not required in all configurations.
Antitamper ➁ Regulators with control range 0 to 100 psig (0 to 6.8 bar) and 0.20 Cv have
nut zinc-plated steel range spring.
➂ Not shown.
➃ Regulators with control ranges higher than 0 to 100 psig (0 to 6.8 bar) are
assembled with two diaphragms.
Pressure Regulators—K Series 9
Dimensions
Dimensions, in inches (millimeters), are for reference only and are subject to change.
Second-stage First-stage
panel mounting panel mounting
3.41
(86.5)
2.13 2.16
(54.0) (55.0)
dia dia
8.35 (212)
8.74 (222) for panel-mount option
Panel cutout 1.38 (35.0)
Ordering Information
Build a KCY series regulator ordering number by combining the designators in the sequence shown below.
4 5 6 7 8 9 10 11 12 13 14 15 16
KCY 1 F R F 4 1 2 A 2 0 0 0 0
4 Body Material 8 Ports 13 Isolation and Relief Valves
1 = 316 SS 4 = 1/4 in. female NPT 0 = No valves
2 = Brass CW721R For isolation and relief valve options,
A = 316 SS, ASTM G93 Level E-cleaned 9 Seat Material see page 54.
B = Brass, ASTM G93 Level E-cleaned 1 = PCTFE
C = 316 SS, SC-11–cleaned 2 = PEEK 14 Cylinder Connections
D = Brass, SC-11–cleaned 0 = No connections
10 Flow Coefficient (Cv)
For cylinder connection options and
5 Pressure Control Range 2 = 0.06
pressure ratings, see page 53.
C = 0 to 10 psig (0 to 0.68 bar) 5 = 0.20
D = 0 to 25 psig (0 to 1.7 bar) 7 = 0.50 15 Gauges
E = 0 to 50 psig (0 to 3.4 bar) 0 = No gauges
F = 0 to 100 psig (0 to 6.8 bar) 11 Sensing Mechanism, Vent
A = Alloy X-750 diaphragm, no vent For inlet and outlet gauge options, see
G = 0 to 250 psig (0 to 17.2 bar) page 54.
J = 0 to 500 psig (0 to 34.4 bar) C = Alloy X-750 diaphragm, self vent➀
E =Alloy X-750 diaphragm, captured
16 Options
6 Maximum Inlet Pressure➀ vent, no self vent
0 = No options
P = 3000 psig (206 bar) F =Alloy X-750 diaphragm, self and
3 =3 ft, 1/4 in. FX series metal flexible
R = 3600 psig (248 bar) captured vent➀
hose, 1/4 in. female NPT inlet➀
T = 4351 psig (300 bar)➁ ➀ Available with 0.06 and 0.2 Cv only. Self vent
4 =3 ft, 1/4 in. TH series PTFE-lined,
through second stage only.
W = 6000 psig (413 bar)➁➂ stainless steel braided hose, 1/4 in.
➀ Cylinder Connections and Hose accessories female NPT inlet➀
may limit inlet pressure ratings, see pages
12 Handle, Mounting➀
53 and 56. 2 = Knob For hose options and pressure ratings,
➁ Available only with 316 SS body material and 3 = Antitamper nut see page 56.
PEEK seat material. Not available with SC‑11 6 = Knob, second-stage panel mount
cleaning. ➀ Not available for ASTM G93 Level E-cleaned
7 =Antitamper nut, second-stage and SC-11–cleaned regulators.
REGULATORS
K SERIES
➂ Not available for regulators assembled with
isolation valves. panel mount
9 = Knob, first-stage panel mount
For knob handle color options, see
7 Port Configuration page 56.
A, B, C, E, F, H, K, L, M, N
➀ First stage assembled with antitamper nut.
See Port Configurations, page 52.
Select KCY series regulators are available that meet the testing requirements of
ASTM G175, “Standard Test Method for Evaluating the Ignition Sensitivity and Fault
Tolerance of Oxygen Regulators Used for Medical and Emergency Applications.”
Contact your authorized Swagelok representative.
10 Pressure Regulators and Filters
High-Sensitivity Diaphragm-Sensing,
Pressure-Reducing Regulators (KLF Series)
The KLF series provides high-sensitivity pressure control of gases or liquids with
minimum droop in both low-flow and low-pressure applications.
Body
Pressure Regulators—K Series 11
Dimensions
Dimensions, in inches (millimeters), are for reference only and are subject to change.
Ordering Information
Build a KLF series regulator ordering number by combining the designators in the sequence shown below.
4 5 6 7 8 9 10 11 12 13 14 15 16
KLF 1 B C F 4 1 2 A 2 0 0 0 0
Dimensions
Dimensions, in inches (millimeters), are for reference only and are subject to change.
Ordering Information
Build a KHF series regulator ordering number by combining the designators in the sequence shown below.
4 5 6 7 8 9 10 11 12 13 14 15 16
KHF 1 F R F 8 1 8 A 2 0 0 0 0
Compact, Piston-Sensing,
Pressure-Reducing Regulators (KCP Series)
The KCP series is a compact, piston-sensing pressure regulator with a short stroke
to minimize wear in high-cycling applications.
Inlet Outlet
K SERIES
Dimensions
Dimensions, in inches (millimeters), are for reference only and are subject to change.
1.24
(31.4)
0.28
(7.0)
3.64
(92.5) Mounting holes
10-32, 0.33 deep
(M5 × 0.8, 8.5 deep) 3.31
(84.0)
Ordering Information
Build a KCP series regulator ordering number by combining the designators in the sequence shown below.
4 5 6 7 8 9 10 11 12 13 14 15 16
KCP 1 F R A 2 A 2 P 1 0 0 0 0
16 Options
0 = No options
16 Pressure Regulators and Filters
Elgiloy
and spring body seal spring
Poppet spring Poppet damper,
Seat filter carrier, PTFE
Inlet piston seal, body seal
Outlet
Wetted lubricant PTFE-based
Dimensions
Dimensions, in inches (millimeters), are for reference only and are subject to change.
Panel 0.39 (10.0) thick maximum with 2 lock nuts
Panel 0.63 (16.0) thick maximum with 1 lock nut
Panel cutout 1.38 (35.0) dia
0.75
(19.0)
5.00 Mounting holes 5.00
(127) 10-32, 0.33 deep (127)
(M5 × 0.8, 8.5 deep)
Ordering Information
Build a KPP series regulator ordering number by combining the designators in the sequence shown below.
4 5 6 7 8 9 10 11 12 13 14 15 16
KPP 1 L W A 4 2 2 P 2 0 0 0 0
16 Options
0 = No options
REGULATORS
K SERIES
18 Pressure Regulators and Filters
High-Flow Piston-Sensing,
Pressure-Reducing Regulators (KPF Series)
The KPF series provides minimum droop across the flow range with high accuracy
of outlet pressure.
Dimensions
Dimensions, in inches (millimeters), are for reference only and are subject to change.
2.13 3.15
(54.0) (80.0)
0.75
(19.0)
dia dia
Ordering Information
Build a KPF series regulator ordering number by combining the designators in the sequence shown below.
4 5 6 7 8 9 10 11 12 13 14 15 16
KPF 1 L W A 8 A 8 P 2 0 0 0 0
High-Pressure Piston-Sensing,
Pressure-Reducing Regulators (KHP Series)
The KHP series provides control of supply pressures up to 10 000 psig (689 bar). The
self-venting capability enables downstream pressure reduction in closed-loop systems.
Self-vent seat
K SERIES
Poppet damper
Filter carrier,
filter
Body
Pressure Regulators—K Series 21
Dimensions
Dimensions, in inches (millimeters), are for reference only and are subject to change.
Clearance hole dia 0.31 (8.0)
Panel-mount
assembly shown
2.20 2.83
0.75 3.19 (56.0) (72.0)
(19.0) (81.0)
dia dia
0.96
(24.5)
Mounting holes
10-32, 0.33 deep
(M5 × 0.8, 8.5 deep) 3.94 to 5.20
(100 to 132)
allowable
7.36
(187)
Ordering Information
Build a KHP series regulator ordering number by combining the designators in the sequence shown below.
4 5 6 7 8 9 10 11 12 13 14 15 16
KHP 1 T X A 4 C 2 S 2 0 0 0 0
4 Body Material 7 Port Configuration 12 Handle, Mounting
1 = 316 SS A, B, C, E, F, H, K, L, M, N 2 = Knob
A = 316 SS, ASTM G93 Level E-cleaned See Port Configurations, page 52. 6 = Knob, panel mount
For knob handle color options, see
5 Pressure Control Range 8 Ports page 56.
J = 0 to 500 psig (0 to 34.4 bar) 4 = 1/4 in. female NPT
K = 0 to 750 psig (0 to 51.6 bar) 13 Isolation Valves
T = 10 to 1500 psig (0.68 to 103 bar) 9 Seat, Seal Material 0 = No valves
U = 15 to 2500 psig (1.0 to 172 bar) C = PEEK, fluorocarbon FKM For isolation valve options, see
V = 25 to 3600 psig (1.7 to 248 bar) page 54.
W = 50 to 6000 psig (3.4 to 413 bar)➀
10 Flow Coefficient (Cv)
X = 100 to 10 000 psig (6.8 to 689 bar)➀
2 = 0.06 14 Cylinder Connections
➀ Not available for regulators assembled with
isolation valves.
6 = 0.25 0 = No connections
16 Options
0 = No options REGULATORS
K SERIES
22 Pressure Regulators and Filters
Poppet damper
Filter carrier,
filter
Body Captured vent port
(shown off center for clarity)
Pressure Regulators—K Series 23
Dimensions
Dimensions, in inches (millimeters), are for reference only and are subject to change.
Clearance hole dia 0.31 (8.0)
Panel-mount
assembly shown
VENT
2.20 2.83
0.75 3.19 (56.0) (72.0)
(19.0) (81.0)
dia dia
0.96
(24.5)
Mounting holes
10-32, 0.33 deep
(M5 × 0.8, 8.5 deep) 4.41 to 5.67
(112 to 144)
allowable
7.83
(199)
Ordering Information
Build a KHR series regulator ordering number by combining the designators in the sequence shown below.
4 5 6 7 8 9 10 11 12 13 14 15 16
KHR 1 T X A 4 J 2 U 2 0 0 0 0
4 Body Material 7 Port Configuration 12 Handle, Mounting
1 = 316 SS A, B, C, F, M 2 = Knob
A = 316 SS, ASTM G93 Level E-cleaned See Port Configurations, page 52. 6 = Knob, panel mount
For knob handle color options, see
5 Pressure Control Range 8 Ports page 56.
J = 0 to 500 psig (0 to 34.4 bar) 4 = 1/4 in. female NPT
K = 0 to 750 psig (0 to 51.6 bar) 13 Isolation Valves
T = 10 to 1500 psig (0.68 to 103 bar) 9 Seat, Seal Material 0 = No valves
U = 15 to 2500 psig (1.0 to 172 bar) C = PEEK, fluorocarbon FKM For isolation valve options, see
V = 25 to 3600 psig (1.7 to 248 bar) J = 316 SS, fluorocarbon FKM➀ page 54.
W = 50 to 6000 psig (3.4 to 413 bar)➀ ➀ Not suitable for gas service.
X = 100 to 10 000 psig (6.8 to 689 bar)➀ 14 Cylinder Connections
➀ Not available for regulators assembled with
10 Flow Coefficient (Cv) 0 = No connections
isolation valves.
2 = 0.06
15 Gauges
6 = 0.25
6 Maximum Inlet Pressure 0 = No gauges
X = 10 000 psig (689 bar) For inlet and outlet gauge options, see
11 Sensing Mechanism, Vent
U =316 SS piston, self and captured page 54.
vent
16 Options
0 = No options
REGULATORS
K SERIES
24 Pressure Regulators and Filters
General-Purpose Diaphragm-Sensing
Back-Pressure Regulators (KBP Series)
The KBP series is a high-sensitivity, general-purpose regulator designed to control
back-pressure levels in analytical or process systems upstream of the regulator.
The convoluted diaphragm provides excellent sensitivity and set-point repeatability.
The metal-to-metal diaphragm seal minimizes the potential for leakage.
Dimensions
Dimensions, in inches (millimeters), are for reference only and are subject to change. Tube Butt
Weld Ports
Panel 0.39 (10.0) thick maximum with 2 lock nuts
Panel 0.63 (16.0) thick maximum with 1 lock nut 0.84
Panel cutout 1.38 (35.0) dia (21.3)
3.00
(76.2)
2.13 2.16
(54.0) (55.0)
0.75 VCR Ports
dia (19.0)
dia
0.84
0.75 (21.3)
(19.0)
4.61 Mounting holes 5.00 3.70
(117) 10-32, 0.33 deep (127) (94.0)
(M5 × 0.8, 8.5 deep)
Ordering Information
Build a KBP series regulator ordering number by combining the designators in the sequence shown below.
4 5 6 7 8 9 10 11 12 13 14 15 16
KBP 1 F 0 D 4 A 5 A 2 0 0 0 0
4 Body Material 8 Ports 12 Handle, Mounting
1 = 316 SS 4 = 1/4 in. female NPT 2 = Knob
2 = Brass CW721R T = 1/4 in. × 0.035 in. tube butt weld➀ 3 = 316 SS antitamper nut
A = 316 SS, ASTM G93 Level E-cleaned V = 1/4 in. VCR gland, no nuts➀➁ 6 = Knob, panel mount
B = Brass, ASTM G93 Level E-cleaned X = 1/4 in. rotatable female VCR fitting➀ 7 = 316 SS antitamper nut, panel mount
C = 316 SS, SC-11–cleaned Y = 1/4 in. rotatable male VCR fitting➀ For knob handle color options, see
D = Brass, SC-11–cleaned ➀ Available only with 316 SS body material in A page 56.
port configuration. Not available ASTM G93
Level E-cleaned.
5 Pressure Control Range 13 Valves
➁ For use with VCR split-nuts, which can be
C = 0 to 10 psig (0 to 0.68 bar) ordered separately. See the Swagelok VCR 0 = No valves
D = 0 to 25 psig (0 to 1.7 bar) Metal Gasket Face Seal Fittings catalog
(MS‑01-24).
E = 0 to 50 psig (0 to 3.4 bar)
14 Cylinder Connections
F = 0 to 100 psig (0 to 6.8 bar)
9 Seat, Seal Material 0 = No connections
G = 0 to 250 psig (0 to 17.2 bar)
J = 0 to 500 psig (0 to 34.4 bar) A = Fluorocarbon FKM, PCTFE
B = Kalrez, PCTFE 15 Gauges
C = Fluorocarbon FKM, PEEK 0 = No gauges
6 Maximum Inlet Pressure
D = Kalrez, PEEK For inlet gauge options, see page 54.
0 =Not applicable (equal to pressure
control range)
10 Flow Coefficient (Cv) 16 Options
5 = 0.20 0 = No options
7 Port Configuration
A, D, G, V
11 Sensing Mechanism, Vent
See Port Configurations, page 52.
A = Alloy X-750 diaphragm, no vent
E =Alloy X-750 diaphragm, captured
vent, no self vent REGULATORS
K SERIES
26 Pressure Regulators and Filters
➀ N
ot included in regulators with 0 to 250 psig (0 to 17.2 bar)
Inlet Outlet
K SERIES
control range.
➁ N
ot shown.
➂ Regulators with control range 0 to 250 psig (0 to 17.2 bar) are
assembled with two diaphragms.
Body
Pressure Regulators—K Series 27
Dimensions
Dimensions, in inches (millimeters), are for reference only and are subject to change.
2.13 3.15
(54.0) (80.0) 0.75
dia dia (19.0)
Ordering Information
Build a KFB series regulator ordering number by combining the designators in the sequence shown below.
4 5 6 7 8 9 10 11 12 13 14 15 16
KFB 1 F 0 D 8 A 8 A 1 0 0 0 0
REGULATORS
K SERIES
28 Pressure Regulators and Filters
Compact Piston-Sensing
Back-Pressure Regulators (KCB Series)
The KCB series provides high sensitivity back-pressure control of sampling
conditioning systems. It is ideally suited for use in portable or laboratory analytical
systems as well as being embedded in the instrument bays of OEM equipment or
sampling cabinets.
Body
Pressure Regulators—K Series 29
Dimensions
Dimensions, in inches (millimeters), are for reference only and are subject to change.
1.24
(31.4)
0.28
(7.0)
3.64
(92.5) Mounting holes
10-32, 0.33 deep
(M5 × 0.8, 8.5 deep) 3.31
(84.0)
Ordering Information
Build a KCB series regulator ordering number by combining the designators in the sequence shown below.
4 5 6 7 8 9 10 11 12 13 14 15 16
KCB 1 F 0 D 2 A 5 P 1 0 0 0 0
Dimensions
Dimensions, in inches (millimeters), are for reference only and are subject to change.
Panel 0.39 (10.0) thick maximum with 2 lock nuts
Panel 0.63 (16.0) thick maximum with 1 lock nut
Panel cutout 1.38 (35.0) dia
0.75
(19.0)
5.00 Mounting holes 5.00
(127) 10-32, 0.33 deep (127)
(M5 × 0.8, 8.5 deep)
Ordering Information
Build a KPB series regulator ordering number by combining the designators in the sequence shown below.
4 5 6 7 8 9 10 11 12 13 14 15 16
KPB 1 L 0 A 4 2 2 P 2 0 0 0 0
REGULATORS
K SERIES
32 Pressure Regulators and Filters
High-Pressure Piston-Sensing
Back-Pressure Regulators (KHB Series)
The KHB series provides control of back pressures up to 10 000 psig (689 bar) with
high sensitivity across the control range.
Body
Pressure Regulators—K Series 33
Dimensions
Dimensions, in inches (millimeters), are for reference only and are subject to change.
Clearance hole dia 0.31 (8.0)
Panel-mount
assembly shown
Panel cutout minimum dia 2.25 (57.2)
2.20 2.83
0.75 3.19 (56.0) (72.0)
(19.0) (81.0)
dia dia
0.96
(24.5)
Mounting holes
10-32, 0.33 deep
(M5 × 0.8, 8.5 deep) 3.94 to 5.20
(100 to 132)
allowable
7.36
(187)
Ordering Information
Build a KHB series regulator ordering number by combining the designators in the sequence shown below.
4 5 6 7 8 9 10 11 12 13 14 15 16
KHB 1 T 0 D 4 C 2 P 2 0 0 0 0
Dimensions
Dimensions, in inches (millimeters), are for reference only and are subject to change.
2 mounting holes,
0.50 (12.7) dia
Outlet Outlet
9.65
(245)
6.30 5.00
(160) (127)
4 mounting holes,
1.57 2.48 Inlet 2.99 Inlet 0.25 (6.4) dia
(40.0) (63.0) (76.0)
8.46 7.68
(215) (195)
Ordering Information
Build a KCM series regulator ordering number by combining the designators in the sequence shown below.
4 5 6 7 8 9 10 11 12 13 14 15 16
KCM 1 F F B 4 1 2 A D 0 0 1 0
4 Body Material 7 Port Configuration 13 Isolation and Relief Valves
1 = 316 SS B, C, L 0 = No valves
A = 316 SS, ASTM G93 Level E-cleaned See Port Configurations, below. For isolation and relief valve options,
see page 54.
5 Pressure Control Range 8 Ports
C = 0 to 10 psig (0 to 0.68 bar) 4 = 1/4 in. female NPT 14 Cylinder Connections
0 = No connections
D = 0 to 25 psig (0 to 1.7 bar)
9 Seat Material Cylinder connections available only with
E = 0 to 50 psig (0 to 3.4 bar)
1 = PCTFE hose option. For cylinder connection
F = 0 to 100 psig (0 to 6.8 bar)
2 = PEEK options and pressure ratings, see page
G = 0 to 250 psig (0 to 17.2 bar)➀
J = 0 to 500 psig (0 to 34.4 bar)➁ 53.
10 Flow Coefficient (Cv)
➀ Not available with 100 psig (6.8 bar) 2 = 0.06 15 Gauge Scale
changeover pressure.
1 = psig (bar) (North America only)
➁ Only available with 500 psig (34.4 bar)
changeover pressure. 11 Sensing Mechanism, Vent 2 = bar (psig)
A = Alloy X-750 diaphragm, no vent 3 = psig (bar)
6 Nominal Changeover Pressure➀ C = Alloy X-750 diaphragm, self vent➀ 4 = MPa
E =Alloy X-750 diaphragm, captured 5 = psig (kPa)
F = 100 psig (6.8 bar)
G = 250 psig (17.2 bar) vent, no self vent➀ For more information, see page 54.
J = 500 psig (34.4 bar) F =Alloy X-750 diaphragm, self and
captured vent➀ 16 Options
➀ Self and captured vent options on line 0 = No options
For 4351 psig (300 bar) inlet➁
regulator only. 3 =3 ft, 1/4 in. FX series metal flexible
5 = 100 psig (6.8 bar)
hose, 1/4 in. female NPT inlet➀
6 = 250 psig (17.2 bar) 12 Line Regulator Handle 4 =3 ft, 1/4 in. TH series PTFE-lined,
7 = 500 psig (34.4 bar) D = Knob
REGULATORS
Steam tube
Inlet
Pressure Regulators—K Series 37
Dimensions
Dimensions, in inches (millimeters), are for reference only and are subject to change.
1.00 1.75
(25.4) (44.5)
0.75
(19.0)
5.20
(132) Mounting holes
10-32, 0.33 deep
(M5 × 0.8, 8.5 deep)
0.50
(12.7)
dia
Ordering Information
Build a KSV series regulator ordering number by combining the designators in the sequence shown below.
4 5 6 7 8 9 10 11 12 13 14 15 16
KSV 1 F R 1 3 2 2 A 3 0 0 0 0
4 Body Material 8 Ports 12 Handle, Mounting
1 = 316 SS 3 =1/8 in. female NPT inlet; 3 = Antitamper nut
A = 316 SS, ASTM G93 Level E-cleaned 1/4 in. female NPT outlet(s) 7 = Antitamper nut, panel mount
Technical Data
Maximum Inlet Pressure Electrical • WARNING
■ 3600 psig (248 bar) ■ Supply—120 and 240 V (ac) (± 10 %),
Do not alter or disassemble
Pressure Control Ranges 50/60 Hz any of the flameproof
■ 0 to 10 psig (0.68 bar) through ■ Heater ratings—50, 100, 150, joints within the KEV series
and 200 W regulator. Damage to the
0 to 3600 psig (248 bar)
■ Control temperature range—
regulator resulting in affected
Flow Coefficient (Cv) performance and product safety
75 to 380°F (23 to 193°C)
■ 0.02 or 0.06 is possible.
■ Explosive atmosphere/hazardous
Supply-Pressure Effect
location certification: • WARNING
here is a potential for air to
T
Pressure Control Range ■ A
TEX (Europe) and IECEx
become trapped within the piping
1000 (international)—Group II, Category
system, creating the possibility of
250 and psig 2G, Ex db IIB+H2 T3 Gb
a combustible mixture. This could
Up to 500 psig (68.9 bar) Ambient temperatures: –4 to
100 psig (17.2 and and occur during system startup or
Flow 140°F (–20 to 60°C)
Coefficient (6.8 bar) 34.4 bar) Higher
shutdown. In order to allow the
■ C
SA (Canada and U.S.A.)— KEV heater tube to stabilize at
(Cv ) Supply Pressure Effect, %
Class I, Div 1, Groups B, C, and D; ambient temperature, turn off
0.02 0.3 0.5 2.2
T3; CSA Encl Type 4 the power to the regulator during
0.06 1.0 1.5 7.2 Ambient temperatures: –58 to
REGULATORS
Dimensions
Dimensions, in inches (millimeters), are for reference only and Base-Mounted
are subject to change.
5.71
Side-Mounted 5.71 (145)
(145)
REGULATORS
K SERIES
9.76
(248)
5.12
(130) 12.6
5.35 (320)
5.79 (136)
3.74 3.07 (147)
(95.0) (78.0)
3.07
(78.0)
5.55
(141)
0.87
3.60 (22.0)
(91.5)
40 Pressure Regulators and Filters
Ordering Information
Build a KEV series regulator ordering number by combining the designators in the sequence shown below.
4 5 6 7 8 9 10 11 12 13 14 15 16
KEV 1 F R A 3 2 2 A X 0 0 0 G
4 Body Material 7 Port Configuration 13 Valves
1 = 316 SS Side Mount—A, X, 1, 2 0 = No valves
A = 316 SS, ASTM G93 Level E-cleaned Base Mount—A, B, X, Y, Z
See Port Configurations, below. 14 Cylinder Connections
5 Pressure Control Range 0 = No connections
Diaphragm Sensing 8 Ports
C = 0 to 10 psig (0 to 0.68 bar) 3 =1/8 in. female NPT inlet; 15 Gauges
D = 0 to 25 psig (0 to 1.7 bar) 1/4 in. female NPT outlet(s) 0 = No gauges
E = 0 to 50 psig (0 to 3.4 bar)
F = 0 to 100 psig (0 to 6.8 bar) 9 Seat Material 16 Heater, Controller
G = 0 to 250 psig (0 to 17.2 bar) 2 = PEEK 75 to 380°F 75 to 380°F
J = 0 to 500 psig (0 to 34.4 bar) (23 to 193°C), 120 V (23 to 193°C), 240 V
Piston Sensing 10 Flow Coefficient (Cv) G = 50 W 6 = 50 W
L = 0 to 1000 psig (0 to 68.9 bar) 1 = 0.02 H = 100 W 7 = 100 W
M = 0 to 1500 psig (0 to 103 bar) 2 = 0.06 J = 150 W 8 = 150 W
N = 0 to 2000 psig (0 to 137 bar) K = 200 W 9 = 200 W
P = 0 to 3000 psig (0 to 206 bar) 11 Sensing Mechanism
R = 0 to 3600 psig (0 to 248 bar) A =Alloy X-750 diaphragm (outlet
pressures up to 500 psig
6 Maximum Inlet Pressure➀ [34.4 bar])
F = 100 psig (6.8 bar)➁ P =316 SS piston (outlet pressures
J = 500 psig (34.4 bar)➁ above 500 psig [34.4 bar])
L = 1000 psig (68.9 bar)➁
R = 3600 psig (248 bar) 12 Handle, Mounting
➀ For better resolution and control, select a W = Antitamper nut, side mount
pressure that closely matches system pressure.
➁ Available with diaphragm sensing mechanism
X = Antitamper nut, base mount
only.
Port Configurations➀
Outlet and auxiliary ports on the same face.
1 Y
Base inlet
Z
2
REGULATORS
K SERIES
A
A
X
➀ Regulator is rotatable B
360° in relation to
terminal box. Aux
Pressure Regulators—K Series 41
KPR Series
Flow Coefficient 0.06; Flow Coefficient 0.20;
Maximum Inlet Pressure 3600 psig (248 bar) Maximum Inlet Pressure 3600 psig (248 bar)
Pressure Control Ranges Pressure Control Range
0 to 10 psig (0 0 to 25 psig 0 to 25 psig
to 0.68 bar) (0 to 1.7 bar) (0 to 1.7 bar)
Nitrogen Flow, std L/min Nitrogen Flow, std L/min
0 40 80 120 160 200 240 280
25
1.5
Inlet Pressure
Outlet Pressure, psig
2.0 02.0
0 40 80 120 160 200 240 280
20 20 500 psig
2200 psig 1.0 100 psig (34.4 bar) 1.0
100 psig (151 bar)
(6.8 bar) 500 psig (6.8 bar)
(34.4 bar)
0 0
0 5.0 10 15 20 25 30 35 40 0 5.0 10 15 20 25 30 35
Nitrogen Flow, std ft3/min Nitrogen Flow, std ft3/min
0.15
60
K SERIES
0 400 800 1200 1600 4,0
0.05
4,0 60
400
Inlet Pressure 25 3,0 EURO - KPR
3,0 2200 psig (151 bar) EURO - KPR — 0.06 Cv 40
Outlet Pressure, psig
40
Outlet Pressure, bar
10 0
0 0 0 200 400 600 800
1000 500 psig 2.0 4.0 6.0 8.0 10
200 400 600 800 1000
(34.4 bar) 1000 psig 2200 psig 5.0 1000 psig
(68.9 bar) 500 psig
(151 bar) (34.4 bar) (68.9 bar)
1.5 0.15
0
0 10 20 30 40 50 60 70
Nitrogen Flow, std ft3/min Nitrogen Flow, std ft3/min
1.0
0.5 0.10 CHINA - KPR
0.5
0.4
0.4 0 10 20 30 40 50 60 70
0.5 0.05
400
0.3
JAPAN - KPR — 0.06 Cv JAPAN - KPR
25
0.3
42 Pressure Regulators and Filters
KCY Series
Flow Coefficient 0.06; Flow Coefficient 0.20;
Maximum Inlet Pressure 3600 psig (248 bar) Maximum Inlet Pressure 3600 psig (248 bar)
Pressure Control Ranges Pressure Control Range
0 to 10 psig 0 to 25 psig 0 to 25 psig
(0 to 0.68 bar) (0 to 1.7 bar) (0 to 1.7 bar)
Nitrogen Flow, std L/min Nitrogen Flow, std L/min
Outlet Pressure, psig
2200 psig
(151 bar)
Outlet Pressure, psig
25
K SERIES
300
2200 psig 20
Inlet Pressure (151 bar)
600 psig
15
(41.3 bar) 200
1000 psig Inlet Pressure
(68.9 bar) 2200 psig 10
600 psig
(41.3 bar) (151 bar)
600 psig 2200 psig 100
(41.3 bar) 1000 psig (151 bar) 5.0
1000 psig
(68.9 bar) (68.9 bar)
0
0 10 20 30 40 50 60
Nitrogen Flow, std ft3/min Nitrogen Flow, std ft3/min
0 10 20 30 40 50 60
400
25
300
20
Pressure Regulators—K Series 43
KLF Series
Flow Coefficient 0.02; Flow Coefficient 0.06;
Maximum Inlet Pressure 3600 psig (248 bar) Maximum Inlet Pressure 3600 psig (248 bar)
Pressure Control Range Pressure Control Ranges
0 to 10 psig 0 to 10 psig 0 to 25 psig
(0 to 0.68 bar) (0 to 0.68 bar) (0 to 1.7 bar)
Nitrogen Flow, std L/min Nitrogen Flow, std L/min
Outlet Pressure, psig
2200 psig
100 psig (151 bar)
(6.8 bar) 500 psig
(34.4 bar)
Inlet Pressure
3000 psig (206 bar)
Outlet Pressure, psig
Inlet Pressure
2200 psig
Outlet Pressure, bar
2200 psig
(151 bar) 500 psig 1000 psig
(34.4 bar) (68.9 bar)
5000 psig
(344 bar)
500 psig
100 psig (34.4 bar)
3000 psig
(6.8 bar) (206 bar)
Inlet Pressure
2200 psig
(151 bar)
500 psig
(34.4 bar) 1000 psig
(68.9 bar)
KCP Series
Flow Coefficient 0.06; Maximum Inlet Pressure 3600 psig (248 bar)
100 psig
(6.8 bar)
500 psig 100 psig
100 psig (34.4 bar) (6.8 bar)
(6.8 bar) 500 psig 2200 psig 500 psig 2200 psig
(34.4 bar) (151 bar) (34.4 bar) (151 bar)
2200 psig
Outlet Pressure, bar
500 psig
(34.4 bar)
1000 psig 2200 psig 1000 psig 2200 psig
(68.9 bar) (151 bar) (68.9 bar) (151 bar)
Flow Coefficient 0.20; Maximum Inlet Pressure 3600 psig (248 bar)
Pressure Control Ranges Pressure Control Ranges
0 to 25 psig 0 to 100 psig 0 to 500 psig 0 to 1500 psig
(0 to 1.7 bar) (0 to 6.8 bar) (0 to 34.4 bar) (0 to 103 bar)
Nitrogen Flow, std L/min Nitrogen Flow, std L/min
REGULATORS
K SERIES
Inlet Pressure
2200 psig
Outlet Pressure, psig
Inlet Pressure
Outlet Pressure, bar
KHP Series
Flow Coefficient 0.06; Maximum Inlet Pressure 10 000 psig (689 bar)
Pressure Control Ranges Pressure Control Range
0 to 500 psig 0 to 750 psig 10 to 1500 psig
(0 to 34.4 bar) (0 to 51.6 bar) (0.68 to 103 bar)
Nitrogen Flow, std L/min Nitrogen Flow, std L/min
Inlet Pressure
Inlet Pressure 8000 psig (551 bar)
Outlet Pressure, psig
1000 psig
(68.9 bar)
1500 psig
8000 psig (103 bar)
(551 bar)
1000 psig 5000 psig
(68.9 bar) (344 bar)
Inlet Pressure
8000 psig (551 bar)
Inlet Pressure
Outlet Pressure, psig
8000 psig
(551 bar) 5000 psig
(344 bar)
8000 psig (551 bar)
3000 psig
(206 bar) 5500 psig (378 bar)
3500 psig
(241 bar)
8000 psig
(551 bar) 1500 psig 5000 psig 8000 psig
(103 bar) (344 bar) (551 bar)
Inlet Pressure
K SERIES
9000 psig
Outlet Pressure, psig
(620 bar)
Inlet Pressure
9000 psig (620 bar)
8000 psig
3500 psig 5000 psig (551 bar)
(241 bar) (344 bar)
KPP Series
Flow Coefficient 0.02; Flow Coefficient 0.06;
Maximum Inlet Pressure 2000 psig (137 bar) Maximum Inlet Pressure 2000 psig (137 bar)
Pressure Control Range Pressure Control Ranges
0 to 1000 psig 0 to 1000 psig 0 to 1500 psig 0 to 2000 psig
(0 to 68.9 bar) (0 to 68.9 bar) (0 to 103 bar) (0 to 137 bar)
Nitrogen Flow, std L/min Nitrogen Flow, std L/min
Inlet Pressure
2000 psig
Outlet Pressure, psig
Inlet Pressure
1000 psig 2000 psig
(68.9 bar) (137 bar)
1000 psig
(68.9 bar)
Inlet Pressure
5000 psig (344 bar)
Outlet Pressure, psig
5000 psig
(344 bar)
2000 psig
(137 bar) 3000 psig
(206 bar)
0 to 250 psig
(0 to 17.2 bar)
KCB Series
Flow Coefficient 0.20
Nitrogen Flow, std L/min
Inlet Pressure, psig
0 to 250 psig
(0 to 17.2 bar)
REGULATORS
K SERIES
50 Pressure Regulators and Filters
KPB Series
Flow Coefficient 0.06 Flow Coefficient 0.20
Nitrogen Flow, std L/min Nitrogen Flow, std L/min
0 to 1000 psig
0 to 1000 psig (0 to 68.9 bar)
(0 to 68.9 bar)
0 to 3000 psig
(0 to 206 bar)
KHB Series
Flow Coefficient 0.06 Flow Coefficient 0.25
Nitrogen Flow, std L/min Nitrogen Flow, std L/min
15 to 2500 psig
(1.0 to 172 bar)
REGULATORS
K SERIES
Nitrogen Flow, std ft3/min
52 Pressure
Gi Regulators and Filters R
Port Configurations
Port G
configurations
o Gi are available
Go as shown in the regulator ordering information
Pressure Reducing — right-to-left Pressure Reducing — r
pages. The symbols indicate the port location of factory-assembled accessories.
For alternative accessory locations, contact your authorized Swagelok
R
representative.
Go/R
Select regulators are available
Port Configuration Symbols on special order with additional
Filtered Accessory Gi Inlet gauge R Relief valve port configurations. Contact your
Inlet Go/R
Go Outlet gauge
Pressure
Pressure
Pressure
Go/R Outlet gauge or relief
Reducing
Reducing
Reducing — right-to-left
— right-to-left
— right-to-left
authorized Swagelok representative
Filtered main inlet valve for more information.
Outlet
GoG/R
o/R Go/R i Go
Go/R Go Gi GoGoG/R GoGiGi Go Gi Go Gi Go Gi Go Go Gi
Go/R Gi GoG/R
i Gi R R RR
GoG/R GoG
/Ri Gi Gi Go Gi Go Gi Go Gi Go Gi Go Gi Go
i
Back Pressure — right-to-left
Back Pressure — right-to-left
Gi Configuration Gi R R RR R
G G Gi G o G i G o Gi Go Gi Go
Back-Pressure
Back Pressure Regulators
—i right-to-left
Back
Back Pressure —i right-to-left
Pressure R
— right-to-left R R MPC Port Configurations
R R
Right-to-Left Flow Pressure Reducing
Go/R Go/R Go Go Go R R
Gi Gi Gi Gi Gi Gi
Inlet Outlet Outlet Outlet
R Pressure
Back Pressure
Back R left-to-right
— — left-to-right 2-Port 3-Port
Designator A D V Designator 5 6
REGULATORS
Go Go
K SERIES
Gi Gi
Outlet Inlet Inlet Inlet
Configuration Configuration Outlet
Back
Back Pressure Pressure — left-to-right
— left-to-right
Back Pressure — left-to-right
Gi Gi
2-Port 3-Port
Designator A G Designator 7 8
Gi Gi Gi
Gi Gi Gi
Pressure Regulators—K Series 53
Cylinder Connections
■ Available in a variety of 4 in (100 mm) long CGA, BS or DIN
connections
■ Stainless steel construction
Insert a designator into the ordering number as shown in the
appropriate regulator ordering information pages.
bar (psig) 2 B H B ➀ Not available on KPR, KCY, KCM, KLF, and KHF series regulators, because a
K SERIES
0 to 10 (0 to 0.68)
■ 392°F (200°C)
Weight Air Flow, std ft3/min
■ 0.26 lb (0.12 kg)
Ports
■ 1/4 in. NPT male inlet and female outlet
Cleaning
Hoses are not available assembled to ASTM G93 Level E or
SC‑11 specially-cleaned regulators.
Maintenance Kits
REGULATORS
K SERIES
Maintenance Kits
KPR, KCP, AND KBP Series Maintenance Kits
Maintenance kits include: Maintenance Kits for Other Maintenance Instructions
■ all wetted components, except for Regulator Series Maintenance instructions for all
the regulator body and piston, if Maintenance kits for KLF, KHF, KPP, Swagelok regulators are available from
applicable KPF, KHP, KHR, KFB, KCB, KCY, KPB, your Swagelok website.
■ wetted lubricant with MSDS KHB, KSV, and KEV series regulators
are available. Maintenance Tools
■ instructions.
To order, contact your authorized Specially designed tools and tool kits
Swagelok representative; to ensure are available to assist in the service
correct kit contents, please provide the and repair of Swagelok regulators.
original regulator ordering number. Contact your authorized Swagelok
representative for more information.
Ordering Information
Build a maintenance kit ordering number by combining the designators in the sequence shown below.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
K P R 1 D 0 0 4 1 2 A 0 - K I T
1 2 3 Regulator Series 6 Maximum Inlet Pressure 10 Flow Coefficient (Cv)
KPR = KPR 0 = Not applicable 1 = 0.02
KCP = KCP 2 = 0.06
KBP = KBP 7 Port Configuration 5 = 0.20➀➁
0 = Not applicable 7 = 0.50➀
4 Body Material, Cleaning ➀ Not available for KCP series with MPC platform
port configuration.
1 = 316 SS and brass 8 Ports (Filter Size) ➁ Required for KBP series.
C = 316 SS and brass, SC‑11 cleaned KPR Series
4 = 1/4 in. female NPT 11 Sensing Mechanism, Vent
5 Pressure Control Range 0 = All other end connections
KPR Series
KPR and KBP Series KBP Series A =Alloy X-750 diaphragm, no-vent
D =0 to 10 psig (0 to 0.68 bar) and 0 = Not applicable models and captured-vent models
0 to 25 psig (0 to 1.7 bar)
KCP Series C =Alloy X-750 diaphragm, self-vent
F =0 to 50 psig (0 to 3.4 bar) and
0 to 100 psig (0 to 6.8 bar) 2 = 1/8 in. female NPT models and self- and captured-
J =0 to 250 psig (0 to 17.2 bar) and M = MPC platform vent models
0 to 500 psig (0 to 34.4 bar) KBP Series
KCP Series 9 Seat, Seal Material A =Alloy X-750 diaphragm, all models
G =0 to 10 psig (0 to 0.68 bar), KPR Series KCP Series
0 to 25 psig (0 to 1.7 bar), 1 = PCTFE P = 316 SS piston
0 to 50 psig (0 to 3.4 bar), 2 = PEEK
REGULATORS
K SERIES
0 to 100 psig (0 to 6.8 bar), and 12 Handle, Mounting
KBP and KCP Series
0 to 250 psig (0 to 17.2 bar)
A = Fluorocarbon FKM, PCTFE 0 = Not applicable
M =0 to 500 psig (0 to 34.4 bar),
0 to 1000 psig (0 to 68.9 bar), and B = Kalrez, PCTFE
0 to 1500 psig (0 to 103 bar)➀ C = Fluorocarbon FKM, PEEK
D = Kalrez, PEEK
➀ Not available with MPC platform port
configuration.
58 Pressure Regulators and Filters
Additional Products
Filters
Swagelok offers a variety of filters, filter elements,
and sizes.
■ 316 SS and brass materials
■ Sintered and strainer elements
■ Tee type, inline, and all-welded models
For more information about Swagelok filters,
see the Filters—FW, F, and TF Series catalog
(MS‑01‑92).
Transducers
Swagelok industrial pressure transducers
electronically monitor fluid system pressure
in a variety of analytical and process
applications.
■ Accurate and repeatable readings
■ Swagelok tube adapter end connections
available for ease of installation and
maintenance
■ CE compliant
For more information about Swagelok
industrial pressure transducers, see the
Industrial Pressure Transducers catalog,
(MS‑02‑225).