You are on page 1of 59

Pressure Regulators—K Series 1

www.swagelok.com

Pre s sure Re gulators


K Se rie s

REGULATORS
K SERIES

■ Pressure-reducing models

■ Back-pressure models

■ Gas cylinder changeover model

■ Vaporizing models
2 Pressure Regulators and Filters

Contents
High-Flow High-Pressure
Operation, 3
(KPF Series), 18 (KHB Series), 32
Selection, 3

Testing, 4

Cleaning and Packaging, 4

Features, 5
High-Pressure
Pressure-Reducing (KHP Series), 20 Specialty Pressure-Reducing

Gas Cylinder
General-Purpose Changeover
(KPR Series), 6 (KCM Series), 34

High-Pressure
Hydraulic
Two-Stage (KHR Series), 22
(KCY Series), 8

Steam-Heated
Vaporizing
(KSV Series), 36

Back-Pressure
High-Sensitivity
(KLF Series), 10 General-Purpose
(KBP Series), 24 Electrically Heated
Vaporizing
(KEV Series), 38

High-Flow,
High-Sensitivity
High-Flow,
(KHF Series), 12
High-Sensitivity
(KFB Series), 26

Compact
(KCP Series), 14
Compact
(KCB Series), 28

Flow Data
REGULATORS
K SERIES

Pressure-Reducing Regulators, 41
Back-Pressure Regulators, 49
Medium- to Medium- to
High-Pressure High-Pressure Port Configurations, 52
(KPP Series), 16 (KPB Series), 30
Options and Accessories, 53

Maintenance Kits, 56
Pressure Regulators—K Series 3

Pressure Regulator Operation


Regulators reduce the pressure of a gas or liquid from a source, such as a cylinder or compressor, to a lower value needed
by a device, such as an analyzer. A pressure regulator provides better resolution and control when its inlet and control range
pressures closely match the pressure requirements of the fluid handling system. Resolution is the number of handle turns
needed to adjust a regulator from its lowest to highest outlet pressure setting. Control is the ability of the regulator to hold a
given outlet pressure set point.

Pressure-Reducing Regulators Vaporizing


Pressure-reducing regulators control outlet pressure by Vaporization regulators are available with electric and steam
balancing an adjustable spring force against the forces heat to vaporize liquid samples or to preheat gas samples.
caused by inlet and outlet pressures. The spring force is
adjusted by turning the stem/handle, which sets the desired Supply-Pressure Effect
outlet pressure. Supply-pressure effect (SPE) or dependency is a ratio
As inlet pressure decreases, the force balance changes. describing the change in outlet pressure per 100 psi
To compensate, outlet pressure will increase. This supply- (6.8 bar) change in inlet pressure. In other words, for every
pressure effect (SPE) is a function of the design and type 100 psi (6.8 bar) drop in inlet pressure, the outlet pressure
of regulator. If a regulator is subjected to fluctuating inlet will increase by X psi. X is the SPE. For standard pressure-
pressure, and outlet pressure variations are not desirable, a reducing regulators, the outlet pressure increases as supply
two-stage regulator is available. pressure decreases. The opposite is true as supply pressure
increases. This effect can also be realized on system startup
Specialty Pressure-Reducing Regulators or shutdown.
Gas Cylinder Changeover The regulator should be set to the “off” position before turning
the supply pressure on or off to prevent overpressurization
A two-stage gas cylinder changeover model automatically of regulator diaphragms, outlet pressure gauges, or other
switches between two sources. equipment downstream. When selecting an antitamper

K Series Pressure Regulator Selection


Maximum Inlet
MPC Platform

Pressure Control Ranges, psig (bar)


Gas Cylinder
Changeover
Diaphragm

Vaporizing

Vaporizing

Compact,
Electrical

Pressure
psig (bar)
Sensing

Sensing

2 Stage

0 to ....
Steam
Piston

2 10 25 50 100 250 375 500 750


Series (0.13) (0.68) (1.7) (3.4) (6.8) (17.2) (25.8) (34.4) (51.6)
Pressure-Reducing Models
KPR ✓ 6000 ✓ ✓ ✓ ✓ ✓ ✓
KCY (413)
✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
KLF ✓ ✓ ✓ ✓ ✓ ✓ ✓
3600
KHF ✓ ✓ ✓ ✓ ✓ ✓
(248)
KCP ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
KPP ✓ 6000
KPF (413)

KHP ✓ 10 000 ✓ ✓
KHR (689)
✓ ✓ ✓
Specialty Regulators
4351
KCM ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
REGULATORS

(300)
K SERIES

KSV ✓ ✓ 3600 ✓ ✓ ✓ ✓ ✓ ✓
KEV (248)
✓➀ ✓➀ ✓ ✓ ✓ ✓ ✓ ✓ ✓
Back-Pressure Models
KBP ✓ ✓ ✓ ✓ ✓ ✓ ✓
KFB ✓ Equal to ✓ ✓ ✓ ✓ ✓
pressure
KCB ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
control
KPB ✓ range

KHB ✓ ✓ ✓
➀ Outlet pressures up to 500 psig (34.4 bar) require diaphragm sensing mechanism; outlet pressures above 500 psig (34.4 bar) require piston sensing
mechanism.
4 Pressure Regulators and Filters

Testing
model, it is important to make sure that SPE will not cause Every Swagelok K series pressure regulator is pressure
excessive overpressurization on opening and closing of the tested with nitrogen.
supply pressure.

Back-Pressure Regulators
Cleaning and Packaging
Every Swagelok K series pressure regulator is cleaned and
Back-pressure regulators control inlet pressure by balancing
packaged in accordance with Swagelok Standard Cleaning
an adjustable spring force against the force of the inlet
and Packaging (SC-10) (MS-06-62).
pressure. The spring force is adjusted by turning the stem/
handle, which sets the desired inlet pressure. Cleaning and packaging to ensure compliance with product
cleanliness requirements stated in ASTM G93 Level E is
When the force caused by the inlet pressure rises above the
available for brass and stainless steel Swagelok regulators.
force of the spring, the regulator opens until the spring force
and inlet pressure are balanced again. Cleaning and packaging in accordance with Swagelok
Special Cleaning and Packaging (SC-11) (MS‑06‑63), to
• Swagelok pressure regulators are not “Safety ensure compliance with product cleanliness requirements
Accessories” as defined in the Pressure Equipment stated in ASTM G93 Level C is available for select KPR, KCY,
Directive 2014/68/EU. KCP, KBP, and KCB series regulators.
• Do not use the regulator as a shutoff device.
Oxygen Service Hazards
• Self-venting and captured-venting regulators can For more information about hazards and risks of oxygen-
release system fluid to atmosphere. Position the enriched systems, see the Swagelok Oxygen System Safety
self-vent hole or the captured vent connection away technical report (MS-06-13).
from operating personnel. See Venting Options,
page 5, for more information.

Pressure Control Ranges, psig (bar)

10 to 15 to 25 to 50 to 100 to
0 to .... 1500 2500 3600 6000 10 000
1000 1500 2000 3000 3600 4000 (0.68 to (1.0 to (1.7 to (3.5 to (6.8 to
Flow Coefficient (Cv)
(68.9) (103) (137) (206) (248) (275) 103) 172) 248) 413) 689) 0.02 0.06 0.10 0.20 0.25 0.50 1.0 Page

✓ ✓ ✓ ✓ 6
✓ ✓ ✓ 8
✓ ✓ ✓ ✓ 10
✓ 12
✓ ✓ ✓ ✓ ✓ ✓ 14
✓ ✓ ✓ ✓ ✓ ✓ ✓ 16
✓ ✓ ✓ ✓ ✓ 18
✓ ✓ ✓ ✓ ✓ ✓ ✓ 20
✓ ✓ ✓ ✓ ✓ ✓ ✓ 22

✓ 34
REGULATORS
K SERIES

✓ ✓ 36
✓ ✓ ✓ ✓ ✓ ✓ ✓ 38

✓ 24
✓ 26
✓ ✓ 28
✓ ✓ ✓ ✓ ✓ ✓ 30
✓ ✓ ✓ ✓ ✓ ✓ ✓ 32
Pressure Regulators—K Series 5

Swagelok® K Series Pressure Regulator Features

Stem
Fine-pitch threads
enable precise spring
adjustment with low torque.

Stop Plate
This disc provides positive Range Spring
backup to the diaphragm in case Turning the handle compresses
of diaphragm overpressure. the spring, pushing the poppet
away from the seat and
increasing outlet pressure.
Convoluted Diaphragm
The all-metal diaphragm acts
as the sensing mechanism
between the inlet pressure Two-Piece Cap
and the range spring. The The two-piece design provides
convoluted, nonperforated linear load on the diaphragm
design ensures greater seal when the cap ring is
sensitivity and longer life. tightened, eliminating torque
A piston sensing mechanism damage to the diaphragm
(shown below) can during assembly.
accommodate higher
pressures.
Inlet Outlet

Gauze Inlet Filter Poppet Damper


Regulators are susceptible to The poppet damper keeps the
damage from system particles. poppet aligned and reduces
Swagelok pressure-reducing vibration and resonance.
regulators include a 25 µm press
fit filter. It can be removed to use
the regulator in liquid service.
Venting Options
The self-vent option allows excess outlet pressure to vent through the body
cap. This can occur when downstream flow is suddenly reduced or when the
handle is adjusted to a lower pressure with little or no flow downstream.
The captured-vent option includes a 1/8 in. female NPT connection and
stem seal in the body cap➀ to allow monitoring of the diaphragm or piston
sensing mechanism. It also allows containment of hazardous gas or liquid
Filter media should a diaphragm or piston rupture.
Self-vent and captured-vent options can be ordered together so that
hazardous gas or liquid media can be contained if vented.
➀ The captured-vent port is in the bottom of the KHR series body.

REGULATORS
K SERIES

Piston Sensing Mechanism


Piston sensing mechanisms
typically are used to regulate
Fully-Contained Piston
higher pressures than a diaphragm
can withstand. They are also more The piston is contained
resistant to damage caused by by a shoulder in the
pressure spikes and have a short regulator body cap to
stroke to maximize cycle life. prevent piston blowout
if the regulator outlet is
overpressurized.
6 Pressure Regulators and Filters

General-Purpose Diaphragm-Sensing,
Pressure-Reducing Regulators (KPR Series)
The KPR series is a compact regulator with excellent accuracy, sensitivity, and set-
point pressure stability.
Features Supply-Pressure Effect
■ Convoluted, nonperforated diaphragm
Pressure Control Range
■ Metal-to-metal diaphragm seal Up to 250 psig
■ Low internal volume 100 psig (17.2 bar)
Flow
(6.8 bar) and Higher
■ Two-piece cap design provides linear Coefficient
load on the diaphragm seal (Cv ) Supply Pressure Effect, %
■ High-flow, dual-gauze type filter in 0.02 0.3 0.5
inlet ports 0.06 1.0 1.5
0.20 1.7 2.5
Technical Data 0.50 2.3 3.3
Maximum Inlet Pressure
■ 3600 psig (248 bar) Maximum Operating Temperature Ports
■ 6000 psig (413 bar) with PEEK seat ■ 176°F (80°C) with PCTFE seat ■ 1/4 in. female NPT inlet, outlet, and
Pressure Control Ranges ■ 392°F (200°C) with PEEK seat gauge ports (all body materials)
■ 0 to 10 psig (0.68 bar) through ■ 212°F (100°C) with PEEK seat and ■ 1/4 in. tube butt weld inlet, outlet,
0 to 500 psig (34.4 bar) maximum inlet pressure greater than and gauge ports (316 SS body
3600 psig (248 bar) material only)
Flow Coefficient (Cv )
■ 0.06 and 0.20 Weight ■ 1/4 in. VCR® inlet, outlet, and gauge
ports (316 SS body material only)
See page 41 for flow graphs. ■ 2.4 lb (1.1 kg)
■ 0.02 and 0.50 also available

Materials of Construction Brass Alloy


Cover 316 SS CW721R Alloy 400 C‑276
Stem nut Component Material
Knob handle, cover Nylon with 316 SS insert
Stem Knob handle Spring button Zinc-plated steel
Spring stabilizer➀ 301 SS
Spring 316 SS or zinc-plated steel,
stabilizer Spring button Range spring
depending on configuration
Stem, stem nut, cap ring,
Stop plate stop plate, body cap, 316 SS
Range spring panel nuts➁
Cap ring VCR nuts➁ 316 SS —
Body cap
Nonwetted lubricant Hydrocarbon-based
Diaphragm Seat retainer Seat retainer 316 SS Alloy 400
Alloy
C‑276
Seat Poppet Seat PCTFE or PEEK
Filter 316 SS Alloy C-22
Poppet spring Diaphragm➂ Alloy X-750 or alloy C-276
Alloy
Poppet S17400 SS Alloy 400
Inlet Outlet C‑276
REGULATORS
K SERIES

Alloy
Poppet spring Alloy X-750
Poppet C‑276
Filter damper Poppet damper, filter carrier PTFE
carrier, filter
Self-vent seal➁ Fluorocarbon FKM —
Body Brass Alloy
Body 316 SS Alloy 400
CW721R C‑276
Tube butt weld ports,➁
316L SS —
VCR gland ports➁
Wetted lubricant PTFE-based
Wetted components listed in italics.
➀ Not required in all configurations.
➁ Not shown.
➂ Regulators with control ranges higher than 0 to 100 psig (0 to 6.8 bar) are
assembled with two diaphragms.
Pressure Regulators—K Series 7

Dimensions
Dimensions, in inches (millimeters), are for reference only and are subject to change. Tube Butt
Weld Ports
Female NPT Panel 0.39 (10.0) thick maximum with 2 lock nuts
Ports Panel 0.63 (16.0) thick maximum with 1 lock nut 0.84
Panel cutout 1.38 (35.0) dia (21.3)

3.00
(76.2)
2.13 2.16 0.75 VCR Ports
(54.0) (55.0)
(19.0)
dia dia

0.84
0.75 (21.3)
(19.0)
4.61 Mounting holes 5.00 3.70
(117) 10-32, 0.33 deep (127) (94.0)
(M5 × 0.8, 8.5 deep)

Ordering Information
Build a KPR series regulator ordering number by combining the designators in the sequence shown below.

4 5 6 7 8 9 10 11 12 13 14 15 16
KPR 1 F R F 4 1 2 A 2 0 0 0 0
4 Body Material
7 Port Configuration 12 Handle, Mounting
1 = 316 SS
2 = Brass CW721R A, B, C, E, F, H, K, L, M, N 2 = Knob
4 = Alloy 400 See Port Configurations, page 52. 3 = 316 SS antitamper nut
5 = Alloy C-276 6 = Knob, panel mount
8 Ports 7 = 316 SS antitamper nut, panel mount
A = 316 SS, ASTM G93 Level E-cleaned
B = Brass, ASTM G93 Level E-cleaned 4 = 1/4 in. female NPT For knob handle color options, see
C = 316 SS, SC-11–cleaned T = 1/4 in. × 0.035 in. tube butt weld➀ page 56.
D = Brass, SC-11–cleaned V = 1/4 in. VCR gland, no nuts➀➁
X = 1/4 in. rotatable female VCR fitting➀ 13 Isolation and Relief Valves
5 Pressure Control Range Y = 1/4 in. rotatable male VCR fitting➀ 0 = No valves
C = 0 to 10 psig (0 to 0.68 bar)➀ ➀ Available only with 316 SS body material in A For isolation and relief valve options,
D = 0 to 25 psig (0 to 1.7 bar)➀ and F port configurations; does not contain
E = 0 to 50 psig (0 to 3.4 bar) a filter. Not available with maximum inlet see page 54.
pressure greater than 3600 psig (248 bar). Not
F = 0 to 100 psig (0 to 6.8 bar) available ASTM G93 Level E-cleaned. 14 Cylinder Connections
G = 0 to 250 psig (0 to 17.2 bar) ➁ For use with VCR split-nuts, which can be
J = 0 to 500 psig (0 to 34.4 bar) 0 = No connections
ordered separately. See the Swagelok VCR
➀ Select 0.02 or 0.06 flow coefficient if maximum Metal Gasket Face Seal Fittings catalog For cylinder connection options and
inlet pressure is 4351 psig (300 bar) or (MS‑01-24). pressure ratings, see page 53.
6000 psig (413 bar).
9 Seat Material 15 Gauges
6 Maximum Inlet Pressure➀➁ 1 = PCTFE 0 = No gauges
F = 100 psig (6.8 bar) 2 = PEEK
J = 500 psig (34.4 bar) For inlet and outlet gauge options, see
L = 1000 psig (68.9 bar) 10 Flow Coefficient (Cv) page 54.
P = 3000 psig (206 bar) 1 = 0.02 5 = 0.20
R = 3600 psig (248 bar) 16 Options
2 = 0.06 7 = 0.50
T = 4351 psig (300 bar)➂ 0 = No options
W = 6000 psig (413 bar)➂➃ 11 Sensing Mechanism, Vent H =Inboard helium leak test
➀ For better resolution and control, select a A = Alloy X-750 diaphragm, no vent to a maximum leak rate of REGULATORS

pressure that closely matches system pressure.


C = Alloy X-750 diaphragm, self vent➀ 1 × 10–5 std cm3/s➀
K SERIES

➁ Cylinder Connections and Hose accessories


E =Alloy X-750 diaphragm, captured 3 =3 ft, 1/4 in. FX series metal flexible
may limit inlet pressure ratings, see pages
53 and 56. vent, no self vent hose, 1/4 in. female NPT inlet➀
➂ Available only with 316 SS body material and F =Alloy X-750 diaphragm, self and 4 =3 ft, 1/4 in. TH series PTFE-lined,
PEEK seat material. Not available with SC‑11
captured vent➀ stainless steel braided hose, 1/4 in.
cleaning. female NPT inlet➁
➃ Not available for regulators assembled with H = Alloy C-276 diaphragm, no vent
isolation valves. ➀ Available only with 316 SS and brass body For hose options and pressure ratings,
materials and 0.06 and 0.20 Cv. see page 56.
➀ Not available with self vent.
➁ Not available for ASTM G93 Level E-cleaned
Select KPR series regulators are available that meet the testing requirements of and SC-11–cleaned regulators.
ASTM G175, “Standard Test Method for Evaluating the Ignition Sensitivity and Fault
Tolerance of Oxygen Regulators Used for Medical and Emergency Applications.”
Contact your authorized Swagelok sales and service representative.
8 Pressure Regulators and Filters

Two-Stage Diaphragm-Sensing,
Pressure-Reducing Regulators (KCY Series)
The KCY series is designed for use in applications requiring constant outlet pressure
even with wide variations in inlet pressure. This two-stage regulator is comparable to two
single-stage regulators connected in series. The first stage is factory set to reduce the
inlet pressure to 500 psig (34.4 bar). The second stage can be adjusted with the handle to
achieve the required outlet pressure.
This two-stage arrangement minimizes the supply-pressure effect caused by fluctuating inlet
pressure, such as with a depleting gas cylinder. As inlet pressure drops below the setting of the
first stage, the regulator then functions as a single-stage regulator. The first-stage pressure setting
can be reduced while monitoring the pressure at the interstage port, but lower flow may result.

Features Flow Coefficient (Cv )


■ Convoluted, nonperforated diaphragm ■ 0.06 and 0.20
■ Metal-to-metal diaphragm seal See page 42 for flow graphs.
■ Excellent set-point stability ■ 0.50 also available
■ High-flow, dual-gauze type filter in Supply-Pressure Effect Maximum Operating Temperature
inlet ports ■ 176°F (80°C) with PCTFE seat
Pressure Control Range
Technical Data ■ 392°F (200°C) with PEEK seat
Up to 250 psig
Maximum Inlet Pressure 100 psig (17.2 bar) ■ 212°F (100°C) with PEEK seat and
Flow
(6.8 bar) and Higher maximum inlet pressure greater than
■ 3600 psig (248 bar) Coefficient
(Cv ) Supply Pressure Effect, % 3600 psig (248 bar)
■ 6000 psig (413 bar) with PEEK seat
0.06 0.01 0.02 Weight
Pressure Control Ranges 0.20 0.02 0.06 ■ 4.2 lb (1.9 kg)
■ 0 to 10 psig (0.68 bar) through 0.50 0.05 0.13
0 to 500 psig (34.4 bar) Ports
■ 1/4 in. female NPT inlet, outlet, and
gauge ports

Materials of Construction 316 SS Brass CW721R


Cover Component Material
Stem nut Knob handle, cover Nylon with 316 SS insert
316 SS (1st stage)
Stem Spring buttons
Knob handle Zinc-plated steel (2nd stage)
Spring Spring stabilizer➀ 301 SS
stabilizer Spring button 316 SS
(0 to 10 through 0 to 100 psig control ranges)➁
Range springs
Stop plate 2nd stage Zinc-plated steel
range spring (0 to 250 and 0 to 500 psig control ranges)
Cap ring Stems, stem nut, cap
Body cap rings, stop plates,
316 SS
Diaphragm body caps, panel
Seat retainer nuts, antitamper nut

Seat Nonwetted lubricant Hydrocarbon-based


Poppet
Seat retainers, filter 316 SS
Interstage
port plug Poppet spring Seats PCTFE or PEEK
Diaphragms,➃
Poppet damper Alloy X-750
REGULATORS

poppet springs
K SERIES

Poppets S17400 SS
Inlet Outlet
Poppet dampers,
PTFE
filter carrier
Filter carrier, Body Interstage port plug 316 SS with PTFE tape
filter Self-vent seal➂ Fluorocarbon FKM
Body 316 SS Brass CW721R
Wetted lubricant PTFE-based
1st stage Wetted components listed in italics.
range spring ➀ Not required in all configurations.
Antitamper ➁ Regulators with control range 0 to 100 psig (0 to 6.8 bar) and 0.20 Cv have
nut zinc-plated steel range spring.
➂ Not shown.
➃ Regulators with control ranges higher than 0 to 100 psig (0 to 6.8 bar) are
assembled with two diaphragms.
Pressure Regulators—K Series 9

Dimensions
Dimensions, in inches (millimeters), are for reference only and are subject to change.
Second-stage First-stage
panel mounting panel mounting
3.41
(86.5)

2.13 2.16
(54.0) (55.0)
dia dia

8.35 (212)
8.74 (222) for panel-mount option
Panel cutout 1.38 (35.0)

Ordering Information
Build a KCY series regulator ordering number by combining the designators in the sequence shown below.

4 5 6 7 8 9 10 11 12 13 14 15 16
KCY 1 F R F 4 1 2 A 2 0 0 0 0
4 Body Material 8 Ports 13 Isolation and Relief Valves
1 = 316 SS 4 = 1/4 in. female NPT 0 = No valves
2 = Brass CW721R For isolation and relief valve options,
A = 316 SS, ASTM G93 Level E-cleaned 9 Seat Material see page 54.
B = Brass, ASTM G93 Level E-cleaned 1 = PCTFE
C = 316 SS, SC-11–cleaned 2 = PEEK 14 Cylinder Connections
D = Brass, SC-11–cleaned 0 = No connections
10 Flow Coefficient (Cv)
For cylinder connection options and
5 Pressure Control Range 2 = 0.06
pressure ratings, see page 53.
C = 0 to 10 psig (0 to 0.68 bar) 5 = 0.20
D = 0 to 25 psig (0 to 1.7 bar) 7 = 0.50 15 Gauges
E = 0 to 50 psig (0 to 3.4 bar) 0 = No gauges
F = 0 to 100 psig (0 to 6.8 bar) 11 Sensing Mechanism, Vent
A = Alloy X-750 diaphragm, no vent For inlet and outlet gauge options, see
G = 0 to 250 psig (0 to 17.2 bar) page 54.
J = 0 to 500 psig (0 to 34.4 bar) C = Alloy X-750 diaphragm, self vent➀
E =Alloy X-750 diaphragm, captured
16 Options
6 Maximum Inlet Pressure➀ vent, no self vent
0 = No options
P = 3000 psig (206 bar) F =Alloy X-750 diaphragm, self and
3 =3 ft, 1/4 in. FX series metal flexible
R = 3600 psig (248 bar) captured vent➀
hose, 1/4 in. female NPT inlet➀
T = 4351 psig (300 bar)➁ ➀ Available with 0.06 and 0.2 Cv only. Self vent
4 =3 ft, 1/4 in. TH series PTFE-lined,
through second stage only.
W = 6000 psig (413 bar)➁➂ stainless steel braided hose, 1/4 in.
➀ Cylinder Connections and Hose accessories female NPT inlet➀
may limit inlet pressure ratings, see pages
12 Handle, Mounting➀
53 and 56. 2 = Knob For hose options and pressure ratings,
➁ Available only with 316 SS body material and 3 = Antitamper nut see page 56.
PEEK seat material. Not available with SC‑11 6 = Knob, second-stage panel mount
cleaning. ➀ Not available for ASTM G93 Level E-cleaned
7 =Antitamper nut, second-stage and SC-11–cleaned regulators.
REGULATORS
K SERIES
➂ Not available for regulators assembled with
isolation valves. panel mount
9 = Knob, first-stage panel mount
For knob handle color options, see
7 Port Configuration page 56.
A, B, C, E, F, H, K, L, M, N
➀ First stage assembled with antitamper nut.
See Port Configurations, page 52.

Select KCY series regulators are available that meet the testing requirements of
ASTM G175, “Standard Test Method for Evaluating the Ignition Sensitivity and Fault
Tolerance of Oxygen Regulators Used for Medical and Emergency Applications.”
Contact your authorized Swagelok representative.
10 Pressure Regulators and Filters

High-Sensitivity Diaphragm-Sensing,
Pressure-Reducing Regulators (KLF Series)
The KLF series provides high-sensitivity pressure control of gases or liquids with
minimum droop in both low-flow and low-pressure applications.

Features Supply-Pressure Effect


■ Large-diameter convoluted,
Pressure Control Range
nonperforated diaphragm for
Up to 25 psig
increased pressure sensitivity 10 psig (1.7 bar)
Flow
■ Metal-to-metal diaphragm seal (0.68 bar) and Higher
Coefficient
■ High-flow, dual-gauze type filter in (Cv ) Supply Pressure Effect, %
inlet ports 0.02 0.1 0.2
0.06 0.4 0.6
Technical Data 0.20 0.7 0.9
Maximum Inlet Pressure 0.50 1.0 1.4
■ 3600 psig (248 bar)
Maximum Operating Temperature
Pressure Control Ranges
■ 176°F (80°C) with PCTFE seat
■ 0 to 2.0 psig (0.13 bar) through
0 to 250 psig (17.2 bar) ■ 392°F (200°C) with PEEK seat

Flow Coefficient (Cv ) Weight


■ 0.02 and 0.06 ■ 4.0 lb (1.8 kg)

See page 43 for flow graphs. Ports


■ 0.20 and 0.50 also available ■ 1/4 in. female NPT inlet, outlet, and
gauge ports

Materials of Construction Component Material


Cover Knob handle, cover Nylon with 316 SS insert
Stem nut
Spring button Zinc-plated steel
Stem Spring stabilizer➀ 301 SS
316 SS or zinc-plated steel,
Knob handle Range spring
depending on configuration
Spring
stabilizer Stem, stem nut, cap ring,
Spring button stop plate, body 316 SS
cap, panel nuts➁
Stop plate Range spring
Nonwetted lubricant Hydrocarbon-based
Body, seat retainer,
Cap ring Body cap filter
316 SS

Seat PCTFE or PEEK


Diaphragm
Diaphragm,➂
Alloy X-750
poppet spring
Seat retainer Poppet
Poppet S17400 SS
Poppet spring Poppet damper,
Seat PTFE
filter carrier
REGULATORS
K SERIES

Wetted lubricant PTFE-based


Inlet Outlet
Wetted components listed in italics.
➀ Not required in all configurations.
Filter carrier, Poppet ➁ Not shown.
filter damper ➂ Regulators with control range 0 to 250 psig (0 to 17.2 bar) are
assembled with two diaphragms.

Body
Pressure Regulators—K Series 11

Dimensions
Dimensions, in inches (millimeters), are for reference only and are subject to change.

Panel 0.39 (10.0) thick maximum with 2 lock nuts


Panel 0.63 (16.0) thick maximum with 1 lock nut
Panel cutout 1.38 (35.0) dia

2.13 3.15 0.75


(54.0) (80.0) (19.0)
dia dia

0.75 Mounting holes


(19.0) 10-32, 0.33 deep
4.76 (M5 × 0.8, 8.5 deep) 5.08
(121) (129)

Ordering Information
Build a KLF series regulator ordering number by combining the designators in the sequence shown below.

4 5 6 7 8 9 10 11 12 13 14 15 16
KLF 1 B C F 4 1 2 A 2 0 0 0 0

4 Body Material 7 Port Configuration 13 Isolation and Relief Valves


1 = 316 SS A, B, C, E, F, H, K, L, M, N 0 = No valves
A = 316 SS, ASTM G93 Level E-cleaned See Port Configurations, page 52. For isolation and relief valve options,
see page 54.
5 Pressure Control Range 8 Ports
B = 0 to 2.0 psig (0 to 0.13 bar)➀ 4 = 1/4 in. female NPT 14 Cylinder Connections
C = 0 to 10 psig (0 to 0.68 bar) 0 = No connection
D = 0 to 25 psig (0 to 1.7 bar) 9 Seat Material For cylinder connection options and
E = 0 to 50 psig (0 to 3.4 bar) 1 = PCTFE pressure ratings, see page 53.
F = 0 to 100 psig (0 to 6.8 bar) 2 = PEEK
G = 0 to 250 psig (0 to 17.2 bar)
15 Gauges
➀ Available with 15 psig (1.0 bar) maximum inlet
10 Flow Coefficient (Cv) 0 = No gauges
pressure only.
1 = 0.02 For inlet and outlet gauge options, see
2 = 0.06 page 54.
6 Maximum Inlet Pressure➀➂
5 = 0.20
C = 15 psig (1.0 bar)➁
7 = 0.50 16 Options
F = 100 psig (6.8 bar)
J = 500 psig (34.4 bar) 0 = No options
11 Sensing Mechanism, Vent 3 =3 ft, 1/4 in. FX series metal flexible
L = 1000 psig (68.9 bar)
A = Alloy X-750 diaphragm, no vent hose, 1/4 in. female NPT inlet➀
P = 3000 psig (206 bar)
E =Alloy X-750 diaphragm, captured 4 =3 ft, 1/4 in. TH series PTFE-lined,
R = 3600 psig (248 bar)
vent, no self vent stainless steel braided hose, 1/4 in.
➀ For better resolution and control, select a
pressure that closely matches system pressure. female NPT inlet➀
➁ Available with 0 to 2.0 psig (0 to 0.13 bar) 12 Handle, Mounting For hose options and pressure ratings,
pressure control range only. 2 = Knob see page 56.
REGULATORS

➂ Cylinder Connections and Hose accessories


K SERIES

may limit inlet pressure ratings, see pages


3 = 316 SS antitamper nut ➀ Not available for ASTM G93 Level E-cleaned
53 and 56. 6 = Knob, panel mount regulators.
7 = 316 SS antitamper nut, panel mount
For knob handle color options, see
page 56.
12 Pressure Regulators and Filters

High-Flow, High-Sensitivity Diaphragm-Sensing,


Pressure-Reducing Regulators (KHF Series)
The KHF series combines the high-flow capabilities—1.0 Cv —of a bulk distribution
regulator with the high sensitivity and accuracy of a point-of-use regulator.

Features Supply-Pressure Effect


■ Large-diameter convoluted,
Pressure Control Range
nonperforated diaphragm for
Up to 100 psig
increased pressure sensitivity 50 psig (6.8 bar)
Flow
■ Metal-to-metal diaphragm seal (3.4 bar) and Higher
Coefficient
■ High-flow dual-gauze type filter in (Cv ) Supply Pressure Effect, %
inlet ports 1.0 0.3 0.4

Technical Data Maximum Operating Temperature


Maximum Inlet Pressure ■ 176°F (80°C) with PCTFE seat
■ 3600 psig (248 bar) ■ 392°F (200°C) with PEEK seat
Pressure Control Ranges Weight
■ 0 to 10 psig (0.68 bar) through ■ 4.4 lb (2.0 kg)
0 to 250 psig (17.2 bar) Ports
Flow Coefficient (Cv ) ■ 1/2 in. female NPT inlet and outlet;
■ 1.0 1/4 in. female NPT gauge port
See page 44 for flow graphs.

Materials of Construction Component Material


Cover Knob handle, cover Nylon with 316 SS insert
Stem nut 316 SS (0 to 250 psig range)
Spring button
Zinc-plated steel (all other ranges)
Stem Spring stabilizer➀ 301 SS
Knob 316 SS (0 to 10 and
Spring handle 0 to 25 psig control ranges)
stabilizer ­Range spring
Zinc-plated steel (0 to 50 through
Spring button 0 to 250 psig control ranges)
Stop plate Stem, stem nut, cap
Range spring ring, stop plate, body 316 SS
Cap ring cap, panel nuts➁
Body cap Nonwetted lubricant Hydrocarbon-based
Diaphragm Body, spring retainer,
Seat retainer seat retainer, filter, 316 SS
Poppet poppet seal retainer
Seat Seat PCTFE or PEEK
Poppet spring Diaphragm➂ Alloy X-750
Spring retainer
Poppet S17400 SS
REGULATORS

Inlet Outlet Poppet spring 302 SS


K SERIES

Poppet seal, filter


PTFE
carrier
Poppet seal Poppet seal spring Elgiloy ®
retainer Wetted lubricant PTFE-based
Filter carrier,
filter Poppet seal Wetted components listed in italics.
and spring ➀ Not included in regulators with 0 to 250 psig (0 to 17.2 bar)
Body control range.
➁ Not shown.
➂ Regulators with control range 0 to 250 psig (0 to 17.2 bar) are
assembled with two diaphragms.
Pressure Regulators—K Series 13

Dimensions
Dimensions, in inches (millimeters), are for reference only and are subject to change.

Panel 0.39 (10.0) thick maximum with 2 lock nuts


Panel 0.63 (16.0) thick maximum with 1 lock nut
Panel cutout 1.38 (35.0) dia

2.13 3.15 0.75


(54.0) (80.0)
(19.0)
dia dia

0.96 Mounting holes


(24.5) 10-32, 0.33 deep
5.00 (M5 × 0.8, 8.5 deep) 5.39
(127) (137)

Ordering Information
Build a KHF series regulator ordering number by combining the designators in the sequence shown below.

4 5 6 7 8 9 10 11 12 13 14 15 16
KHF 1 F R F 8 1 8 A 2 0 0 0 0

4 Body Material 8 Ports 13 Isolation and Relief Valves


1 = 316 SS 8 =1/2 in. female NPT inlet and outlet; 0 = No valves
A = 316 SS, ASTM G93 Level E-cleaned 1/4 in. female NPT gauge port For isolation and relief valve options,
see page 54.
5 Pressure Control Range 9 Seat Material
C = 0 to 10 psig (0 to 0.68 bar) 1 = PCTFE 14 Cylinder Connections
D = 0 to 25 psig (0 to 1.7 bar) 2 = PEEK 0 = No connections
E = 0 to 50 psig (0 to 3.4 bar)
F = 0 to 100 psig (0 to 6.8 bar) 10 Flow Coefficient (Cv) 15 Gauges
G = 0 to 250 psig (0 to 17.2 bar) 8 = 1.0 0 = No gauges
For inlet and outlet gauge options, see
6 Maximum Inlet Pressure➀ 11 Sensing Mechanism, Vent page 54.
F = 100 psig (6.8 bar) A = Alloy X-750 diaphragm, no vent
J = 500 psig (34.4 bar) E =Alloy X-750 diaphragm, captured 16 Options
L = 1000 psig (68.9 bar) vent, no self vent 0 = No options
R = 3600 psig (248 bar)
➀ For better resolution and control, select a 12 Handle, Mounting
pressure that closely matches system pressure.
2 = Knob
3 = 316 SS antitamper nut
7 Port Configuration 6 = Knob, panel mount
A, B, C, E, F, H, K, L, M, N 7 = 316 SS antitamper nut, panel mount
See Port Configurations, page 52. For knob handle color options, see
page 56. REGULATORS
K SERIES
14 Pressure Regulators and Filters

Compact, Piston-Sensing,
Pressure-Reducing Regulators (KCP Series)
The KCP series is a compact, piston-sensing pressure regulator with a short stroke
to minimize wear in high-cycling applications.

Features Supply-Pressure Effect


■ Low internal volume
Pressure Control Range
■ Fully contained piston Up to 500 psig
■ High-flow, dual-gauze type filter in 250 psig (34.4 bar)
Flow
(17.2 bar) and Higher
inlet ports Coefficient
(Cv ) Supply Pressure Effect, %
■ ANSI/ISA 76.00.02-compliant
0.02 0.4 2.6
modular platform component (MPC)
configuration available; MPC platform 0.06 1.3 8.6
regulator does not contain a filter 0.20 2.1 14.5
0.50 3.0 22.6
Technical Data
Maximum Inlet Pressure Maximum Operating Temperature
■ 3600 psig (248 bar) ■ 176°F (80°C) with PCTFE seat
Pressure Control Ranges ■ 392°F (200°C) with PEEK seat
■ 0 to 10 psig (0.68 bar) through Weight
0 to 1500 psig (103 bar) ■ 1.0 lb (0.45 kg)
Flow Coefficient (Cv) Ports
■ 0.06 and 0.20 ■ 1/8 in. female NPT inlet, outlet, and
See page 45 for flow graphs. gauge ports
■ 0.02 and 0.50 also available ■ MPC platform

Materials of Construction Component Material


Thumbwheel handle Anodized aluminum
Thumbwheel
Knob handle,➀ cover➀ Nylon with 316 SS insert
Stem nut handle
Spring button Zinc-plated steel
Stem Spring button Spring stabilizer 301 SS
316 SS or zinc-plated steel,
Range spring
Spring Range spring depending on configuration
stabilizer Stem, stem nut,
316 SS
Body cap body cap, panel nuts➀
Nonwetted lubricant Hydrocarbon-based
Piston seal Body, seat retainer,
316 SS
piston, filter➁

Seat retainer Piston seal Fluorocarbon FKM or Kalrez®


Piston Seat PCTFE or PEEK

Seat Poppet Poppet S17400 SS


Poppet spring 302 SS
Filter carrier➁ PTFE
REGULATORS

Inlet Outlet
K SERIES

Wetted lubricant PTFE-based


Wetted components listed in italics.
Poppet spring
➀ Not shown.
Filter carrier, ➁ MPC platform regulator does not contain a filter.
filter Body
Pressure Regulators—K Series 15

Dimensions
Dimensions, in inches (millimeters), are for reference only and are subject to change.

Panel 0.50 (12.7) thick


maximum between two nuts
Panel cutout 1.38 (35.0) dia

1.81 1.49 1.26


(46.0) (37.8) (32.0)
dia dia dia

1.24
(31.4)
0.28
(7.0)
3.64
(92.5) Mounting holes
10-32, 0.33 deep
(M5 × 0.8, 8.5 deep) 3.31
(84.0)

Ordering Information
Build a KCP series regulator ordering number by combining the designators in the sequence shown below.

4 5 6 7 8 9 10 11 12 13 14 15 16
KCP 1 F R A 2 A 2 P 1 0 0 0 0

4 Body Material 7 Port Configuration 12 Handle, Mounting


1 = 316 SS A, B, C, E, F, H, K, L, M, N, 5, 6 1 = Thumbwheel
A = 316 SS, ASTM G93 Level E-cleaned See Port Configurations, page 52. 2 = Knob
C = 316 SS, SC-11–cleaned 3 = 316 SS antitamper nut
8 Ports 5 = Thumbwheel, panel mount
5 Pressure Control Range 2 = 1/8 in. female NPT 6 = Knob, panel mount
C = 0 to 10 psig (0 to 0.68 bar) M = MPC platform 7 = 316 SS antitamper nut, panel mount
D = 0 to 25 psig (0 to 1.7 bar) For knob handle color options, see
E = 0 to 50 psig (0 to 3.4 bar) 9 Seat, Seal Material page 56.
F = 0 to 100 psig (0 to 6.8 bar) A = PCTFE, fluorocarbon FKM
G = 0 to 250 psig (0 to 17.2 bar) B = PCTFE, Kalrez 13 Isolation Valves
J = 0 to 500 psig (0 to 34.4 bar) C = PEEK, fluorocarbon FKM 0 = No valves
L = 0 to 1000 psig (0 to 68.9 bar) D = PEEK, Kalrez For isolation valve options, see
M = 0 to 1500 psig (0 to 103 bar) page 54.
10 Flow Coefficient (Cv)
6 Maximum Inlet Pressure➀ 1 = 0.02 14 Cylinder Connections
F = 100 psig (6.8 bar) 2 = 0.06 0 = No connections
J = 500 psig (34.4 bar) 5 = 0.20➀
L = 1000 psig (68.9 bar) 7 = 0.50➀
R = 3600 psig (248 bar) 15 Gauges
➀ Not available with MPC platform port
➀ For better resolution and control, select a configuration.
0 = No gauges
pressure that closely matches system pressure. For inlet and outlet gauge options, see
11 Sensing Mechanism page 54. REGULATORS
P = 316 SS piston
K SERIES

16 Options
0 = No options
16 Pressure Regulators and Filters

Medium- to High-Pressure Piston-Sensing,


Pressure-Reducing Regulators (KPP Series)
The KPP series meets the demands of a wide range of gas or liquid applications in
a lightweight, compact installation footprint. These features make the KPP pressure
regulator an ideal pressure control solution within high-density OEM equipment.

Features Supply-Pressure Effect


■ Lightweight, compact design Flow Supply
■ Live-loaded body seals Coefficient Pressure
(Cv ) Effect, %
■ Low internal volume
0.02 2.2
■ High-flow, dual-gauze type filter in
0.06 7.2
inlet ports
Maximum Operating Temperature
Technical Data ■ 392°F (200°C) with 2000 psig
Maximum Inlet Pressure (137 bar) maximum inlet pressure
■ 6000 psig (413 bar) ■ 212°F (100°C) with maximum inlet
Pressure Control Ranges pressure greater than 2000 psig
■ 0 to 1000 psig (68.9 bar) through (137 bar)
0 to 3600 psig (248 bar) Weight
Flow Coefficient (Cv) ■ 2.5 lb (1.2 kg)
■ 0.02 and 0.06 Ports
See page 48 for flow graphs. ■ 1/4 in. female NPT inlet, outlet, and
gauge ports

Materials of Construction Component Material


Cover Knob handle, cover Nylon with 316 SS insert
316 SS (0 to 3000 and
Stem nut 0 to 3600 psig range)
Spring button
Zinc-plated steel
Knob handle (all other ranges)➀
Stem
Spring button Spring stabilizer➁ 301 SS
Spring Range spring Zinc-plated steel
stabilizer Stem, stem nut, cap ring,
316 SS
Piston seal body cap, panel nuts➂
Range spring
and spring Nonwetted lubricant Hydrocarbon-based
Body cap Piston seal Body, seat retainer,
316 SS
retainer filter, piston, piston guide
Piston Seat, piston seal retainer PEEK
Cap ring
Seat retainer Poppet S17400 SS
Piston guide Poppet spring Alloy X-750
Poppet
REGULATORS

Body seal Piston seal spring,


K SERIES

Elgiloy
and spring body seal spring
Poppet spring Poppet damper,
Seat filter carrier, PTFE
Inlet piston seal, body seal
Outlet
Wetted lubricant PTFE-based

Poppet Wetted components listed in italics.


Filter carrier, ➀ 316 SS in regulators with 0 to 2000 psig (0 to 137 bar) control range with
filter damper
6000 psig (413 bar) inlet pressure and regulators with 0 to 2000 psig (0 to
137 bar) control range, 4000 psig (275 bar) inlet pressure, and 0.06 Cv .
Body ➁ Not included in regulators with 316 SS spring button.
➂ Not shown.
Pressure Regulators—K Series 17

Dimensions
Dimensions, in inches (millimeters), are for reference only and are subject to change.
Panel 0.39 (10.0) thick maximum with 2 lock nuts
Panel 0.63 (16.0) thick maximum with 1 lock nut
Panel cutout 1.38 (35.0) dia

2.13 2.16 0.75


(54.0) (55.0)
(19.0)
dia dia

0.75
(19.0)
5.00 Mounting holes 5.00
(127) 10-32, 0.33 deep (127)
(M5 × 0.8, 8.5 deep)

Ordering Information
Build a KPP series regulator ordering number by combining the designators in the sequence shown below.

4 5 6 7 8 9 10 11 12 13 14 15 16
KPP 1 L W A 4 2 2 P 2 0 0 0 0

4 Body Material 7 Port Configuration 12 Handle, Mounting


1 = 316 SS A, B, C, E, F, H, K, L, M, N 2 = Knob
A = 316 SS, ASTM G93 Level E-cleaned See Port Configurations, page 52. 3 = 316 SS antitamper nut
6 = Knob, panel mount
5 Pressure Control Range 8 Ports 7 = 316 SS antitamper nut, panel mount
L = 0 to 1000 psig (0 to 68.9 bar) 4 = 1/4 in. female NPT For knob handle color options, see
M = 0 to 1500 psig (0 to 103 bar) page 56.
N = 0 to 2000 psig (0 to 137 bar) 9 Seat, Seal Material
P = 0 to 3000 psig (0 to 206 bar)➀ 2 = PEEK, PTFE 13 Isolation Valves
R = 0 to 3600 psig (0 to 248 bar)➀ 0 = No valves
➀ Not available with 2000 psig (137 bar) For isolation valve options, see
10 Flow Coefficient (Cv)
maximum inlet pressure.
1 = 0.02 page 54.
2 = 0.06
6 Maximum Inlet Pressure➀
14 Cylinder Connections
N = 2000 psig (137 bar)
11 Sensing Mechanism, Vent 0 = No connections
S = 4000 psig (275 bar)
P = 316 SS piston, no vent
W = 6000 psig (413 bar)
V =316 SS piston, captured vent, no 15 Gauges
➀ For better resolution and control, select a
pressure that closely matches system pressure. self vent 0 = No gauges
For inlet and outlet gauge options, see
page 54.

16 Options
0 = No options

REGULATORS
K SERIES
18 Pressure Regulators and Filters

High-Flow Piston-Sensing,
Pressure-Reducing Regulators (KPF Series)
The KPF series provides minimum droop across the flow range with high accuracy
of outlet pressure.

Features Supply-Pressure Effect


■ High flow coefficient (Cv = 1.0) Flow Supply
■ Balanced poppet for minimal supply- Coefficient Pressure
pressure effect (Cv ) Effect, %
1.0 5.3
■ High-flow, dual-gauze type filter in
inlet ports Maximum Operating Temperature
■ 176°F (80°C) with PCTFE seat
Technical Data
■ 392°F (200°C) with PEEK seat
Maximum Inlet Pressure
■ 6000 psig (413 bar) Weight
■ 4.5 lb (2.1 kg)
Pressure Control Ranges
■ 0 to 1000 psig (68.9 bar) through Ports
0 to 4000 psig (275 bar) ■ 1/2 in. female NPT inlet and outlet;
Flow Coefficient (Cv) 1/4 in. female NPT gauge ports
■ 1.0
See page 44 for flow graphs.

Materials of Construction Component Material


Cover Knob handle, cover Nylon with 316 SS insert
316 SS (0 to 3000 and
Stem nut 0 to 4000 psig range)
Spring button
Knob handle Zinc-plated steel
Stem (all other ranges)
Spring button Spring stabilizer➀ 301 SS
Spring
stabilizer Range spring Zinc-plated steel
Piston seal
and spring Stem, stem nut,
Range spring cap ring, body cap, 316 SS
Piston panel nuts➁
Piston seal retainer Nonwetted lubricant Hydrocarbon-based
Body, spring retainer,
Piston guide Body cap seat retainer, filter, piston,
316 SS
piston guide,
Body seal Cap ring poppet seal retainer
Spring retainer Seat,
Seat retainer PCTFE or PEEK
piston seal retainer
Poppet Poppet S17400 SS
Seat
Poppet spring 302 SS
REGULATORS
K SERIES

Filter carrier, piston seal,


Inlet Outlet poppet seal
PTFE

Piston seal spring,


Poppet spring poppet seal spring
Elgiloy
Filter carrier, Poppet seal Body seal Fluorocarbon FKM
filter retainer Wetted lubricant PTFE-based
Wetted components listed in italics.
Body Poppet seal ➀ Not included in regulators with 316 SS spring button.
and spring ➁ Not shown.
Pressure Regulators—K Series 19

Dimensions
Dimensions, in inches (millimeters), are for reference only and are subject to change.

Panel 0.39 (10.0) thick maximum with 2 lock nuts


Panel 0.63 (16.0) thick maximum with 1 lock nut
Panel cutout 1.38 (35.0) dia

2.13 3.15
(54.0) (80.0)
0.75
(19.0)
dia dia

0.96 Mounting holes


5.39 (24.5) 5.39
(137) 10-32, 0.33 deep (137)
(M5 × 0.8, 8.5 deep)

Ordering Information
Build a KPF series regulator ordering number by combining the designators in the sequence shown below.

4 5 6 7 8 9 10 11 12 13 14 15 16
KPF 1 L W A 8 A 8 P 2 0 0 0 0

4 Body Material 8 Ports 13 Isolation Valves


1 = 316 SS 8 =1/2 in. female NPT inlet and outlet; 0 = No valves
A = 316 SS, ASTM G93 Level E-cleaned 1/4 in. female NPT gauge ports For isolation valve options, see
page 54.
5 Pressure Control Range 9 Seat, Body Seal Material
L = 0 to 1000 psig (0 to 68.9 bar) A = PCTFE, fluorocarbon FKM 14 Cylinder Connections
N = 0 to 2000 psig (0 to 137 bar) C = PEEK, fluorocarbon FKM 0 = No connections
P = 0 to 3000 psig (0 to 206 bar)
S = 0 to 4000 psig (0 to 275 bar) 10 Flow Coefficient (Cv) 15 Gauges
8 = 1.0 0 = No gauges
6 Maximum Inlet Pressure
For inlet and outlet gauge options, see
W = 6000 psig (413 bar) 11 Sensing Mechanism, Vent page 54.
P = 316 SS piston, no vent
7 Port Configuration V =316 SS piston, captured vent, no 16 Options
A, B, C, E, F, H, K, L, M, N self vent 0 = No options
See Port Configurations, page 52.
12 Handle, Mounting
2 = Knob
3 = 316 SS antitamper nut
6 = Knob, panel mount
7 = 316 SS antitamper nut, panel mount
For knob handle color options, see
page 56.
REGULATORS
K SERIES
20 Pressure Regulators and Filters

High-Pressure Piston-Sensing,
Pressure-Reducing Regulators (KHP Series)
The KHP series provides control of supply pressures up to 10 000 psig (689 bar). The
self-venting capability enables downstream pressure reduction in closed-loop systems.

Features Supply-Pressure Effect


■ Thrust roller bearing eases operation
Pressure Control Range
■ Panel-mounting configuration 3600 and
available Up to 6000 psig 10 000
■ High-flow, dual-gauze type filter in 2500 psig (248 and psig
Flow
inlet ports Coefficient (172 bar) 413 bar) (689 bar)
(Cv ) Supply Pressure Effect, %
Technical Data 0.06 1.0 2.6 4.2
Maximum Inlet Pressure 0.25 3.3 8.5 14.6

■ 10 000 psig (689 bar)


Maximum Operating Temperature
Pressure Control Ranges
■ 212°F (100°C)
■ 0 to 500 psig (34.4 bar) through
Weight
100 to 10 000 psig (6.8 to 689 bar)
■ 5.7 lb (2.6 kg)
Flow Coefficient (Cv)
Ports
■ 0.06 and 0.25
■ 1/4 in. female NPT inlet, outlet, and
See page 46 and 47 for flow
gauge ports
graphs.

Materials of Construction Component Material


Cover Knob handle, cover Nylon with 316 SS insert
Knob handle retainer Vent screw Spring buttons, upper spring
Thrust roller button set screw,
Knob handle knob handle retainer, 316 SS
bearing vent screw, stem nuts,
Vent screw body cap
Upper spring
spring
button Vent screw spring 302 SS
Upper spring Vent rod 431 SS
Stem
button set screw Stem CZ114 bronze
Stem nuts
Range spring Thrust roller bearing Hardened carbon steel
Vent rod Range spring Chrome vanadium steel
Body cap
Piston Piston seal backup ring PTFE
Piston seal Nonwetted lubricant Hydrocarbon-based
Piston seal
Lower spring backup ring Body, seat retainer, filter,
button piston, piston guide, 316 SS
Self-vent poppet self-vent seat retainer
Piston guide Self-vent Seat, self-vent seat PEEK

Self-vent seat poppet spring Poppet, self-vent poppet S17400 SS


Poppet spring Alloy X-750
REGULATORS

Self-vent seat
K SERIES

Body seal retainer Poppet damper, filter carrier PTFE


Poppet Self-vent poppet spring 302 SS
Seat retainer
Body seal, piston seal Fluorocarbon FKM
Poppet spring Seat
Wetted lubricant PTFE-based
Inlet Outlet Wetted components listed in italics.

Poppet damper
Filter carrier,
filter
Body
Pressure Regulators—K Series 21

Dimensions
Dimensions, in inches (millimeters), are for reference only and are subject to change.
Clearance hole dia 0.31 (8.0)
Panel-mount
assembly shown

Panel cutout minimum dia 2.25 (57.2)

2.20 2.83
0.75 3.19 (56.0) (72.0)
(19.0) (81.0)
dia dia

0.96
(24.5)
Mounting holes
10-32, 0.33 deep
(M5 × 0.8, 8.5 deep) 3.94 to 5.20
(100 to 132)
allowable
7.36
(187)

Ordering Information
Build a KHP series regulator ordering number by combining the designators in the sequence shown below.

4 5 6 7 8 9 10 11 12 13 14 15 16
KHP 1 T X A 4 C 2 S 2 0 0 0 0
4 Body Material 7 Port Configuration 12 Handle, Mounting
1 = 316 SS A, B, C, E, F, H, K, L, M, N 2 = Knob
A = 316 SS, ASTM G93 Level E-cleaned See Port Configurations, page 52. 6 = Knob, panel mount
For knob handle color options, see
5 Pressure Control Range 8 Ports page 56.
J = 0 to 500 psig (0 to 34.4 bar) 4 = 1/4 in. female NPT
K = 0 to 750 psig (0 to 51.6 bar) 13 Isolation Valves
T = 10 to 1500 psig (0.68 to 103 bar) 9 Seat, Seal Material 0 = No valves
U = 15 to 2500 psig (1.0 to 172 bar) C = PEEK, fluorocarbon FKM For isolation valve options, see
V = 25 to 3600 psig (1.7 to 248 bar) page 54.
W = 50 to 6000 psig (3.4 to 413 bar)➀
10 Flow Coefficient (Cv)
X = 100 to 10 000 psig (6.8 to 689 bar)➀
2 = 0.06 14 Cylinder Connections
➀ Not available for regulators assembled with
isolation valves.
6 = 0.25 0 = No connections

11 Sensing Mechanism, Vent 15 Gauges


6 Maximum Inlet Pressure
P = 316 SS piston, no vent 0 = No gauges
X = 10 000 psig (689 bar)
S = 316 SS piston, self vent For inlet and outlet gauge options, see
page 54.

16 Options
0 = No options REGULATORS
K SERIES
22 Pressure Regulators and Filters

High-Pressure Piston-Sensing, Hydraulic


Pressure-Reducing Regulators (KHR Series)
The KHR series provides control of pressures up to 10 000 psig (689 bar) for both
liquid and gas applications. Metal or polymer seats are available.

Features Flow Coefficient (Cv)


■ Self-venting ■ 0.06
■ Captured vent port in bottom of body See page 47 for flow graphs.
■ Panel-mounting configuration ■ 0.25 also available
available Supply-Pressure Effect
■ Thrust roller bearing eases operation
Pressure Control Range
■ High-flow, dual-gauze type filter in
3600 and
inlet ports Up to 6000 psig 10 000
2500 psig (248 and psig
Technical Data Flow
Coefficient (172 bar) 413 bar) (689 bar)
Maximum Inlet Pressure (Cv ) Supply Pressure Effect, %
■ 10 000 psig (689 bar) 0.06 1.0 2.6 4.2
Pressure Control Ranges 0.25 3.3 8.5 14.6

■ 0 to 500 psig (34.4 bar) through


Maximum Operating Temperature Ports
100 to 10 000 psig (6.8 to 689 bar)
■ 212°F (100°C) ■ 1/4 in. female NPT inlet, outlet, vent,
Weight and gauge ports
■ 6.1 lb (2.75 kg)

Materials of Construction Component Material

Cover Knob handle, cover Nylon with 316 SS insert


Knob handle retainer Vent screw
Spring buttons, upper spring
Knob handle Thrust roller button set screw,
bearing knob handle retainer, 316 SS
Vent screw vent screw, stem nuts,
spring Upper spring vent rod nut, body cap
button Vent screw spring 302 SS
Upper spring
button set screw Stem Vent rod 431 SS
Stem CZ114 bronze
Range spring Stem nuts
Thrust roller bearing Hardened carbon steel
Body cap Vent rod
Range spring Chrome vanadium steel
Lower spring Piston Piston seal backup ring PEEK
button Nonwetted lubricant Hydrocarbon-based
Piston seal
Vent rod nut backup ring Body, seat retainer, filter,
piston, piston guide, 316 SS
Piston seals Self-vent poppet self-vent seat retainer
Piston guide Self-vent Self-vent seat PEEK
poppet spring Seat PEEK or 316 SS
Self-vent seat
Self-vent seat Poppet, self-vent poppet S17400 SS
REGULATORS
K SERIES

Body seals retainer Poppet spring Alloy X-750


Poppet Seat retainer Poppet damper, filter carrier PTFE
Self-vent poppet spring 302 SS
Poppet spring Seat
Body seals, piston seals Fluorocarbon FKM
Wetted lubricant PTFE-based
Inlet Outlet Wetted components listed in italics.

Poppet damper
Filter carrier,
filter
Body Captured vent port
(shown off center for clarity)
Pressure Regulators—K Series 23

Dimensions
Dimensions, in inches (millimeters), are for reference only and are subject to change.
Clearance hole dia 0.31 (8.0)
Panel-mount
assembly shown

Panel cutout minimum dia 2.25 (57.2)

VENT
2.20 2.83
0.75 3.19 (56.0) (72.0)
(19.0) (81.0)
dia dia

0.96
(24.5)
Mounting holes
10-32, 0.33 deep
(M5 × 0.8, 8.5 deep) 4.41 to 5.67
(112 to 144)
allowable
7.83
(199)

Ordering Information
Build a KHR series regulator ordering number by combining the designators in the sequence shown below.

4 5 6 7 8 9 10 11 12 13 14 15 16
KHR 1 T X A 4 J 2 U 2 0 0 0 0
4 Body Material 7 Port Configuration 12 Handle, Mounting
1 = 316 SS A, B, C, F, M 2 = Knob
A = 316 SS, ASTM G93 Level E-cleaned See Port Configurations, page 52. 6 = Knob, panel mount
For knob handle color options, see
5 Pressure Control Range 8 Ports page 56.
J = 0 to 500 psig (0 to 34.4 bar) 4 = 1/4 in. female NPT
K = 0 to 750 psig (0 to 51.6 bar) 13 Isolation Valves
T = 10 to 1500 psig (0.68 to 103 bar) 9 Seat, Seal Material 0 = No valves
U = 15 to 2500 psig (1.0 to 172 bar) C = PEEK, fluorocarbon FKM For isolation valve options, see
V = 25 to 3600 psig (1.7 to 248 bar) J = 316 SS, fluorocarbon FKM➀ page 54.
W = 50 to 6000 psig (3.4 to 413 bar)➀ ➀ Not suitable for gas service.
X = 100 to 10 000 psig (6.8 to 689 bar)➀ 14 Cylinder Connections
➀ Not available for regulators assembled with
10 Flow Coefficient (Cv) 0 = No connections
isolation valves.
2 = 0.06
15 Gauges
6 = 0.25
6 Maximum Inlet Pressure 0 = No gauges
X = 10 000 psig (689 bar) For inlet and outlet gauge options, see
11 Sensing Mechanism, Vent
U =316 SS piston, self and captured page 54.
vent
16 Options
0 = No options
REGULATORS
K SERIES
24 Pressure Regulators and Filters

General-Purpose Diaphragm-Sensing
Back-Pressure Regulators (KBP Series)
The KBP series is a high-sensitivity, general-purpose regulator designed to control
back-pressure levels in analytical or process systems upstream of the regulator.
The convoluted diaphragm provides excellent sensitivity and set-point repeatability.
The metal-to-metal diaphragm seal minimizes the potential for leakage.

Features Flow Coefficient (Cv )


■ Convoluted, nonperforated ■ 0.20
diaphragm See page 49 for flow graphs.
■ Metal-to-metal diaphragm seal Maximum Operating Temperature
■ Low internal volume ■ 176°F (80°C) with PCTFE retainer seal
■ Two-piece cap design provides linear ■ 392°F (200°C) with PEEK retainer seal
load on the seal
Weight
Technical Data ■ 2.4 lb (1.1 kg)

Maximum Inlet Pressure Ports


■ Equal to pressure control range ■ 1/4 in. female NPT inlet, outlet, and
gauge ports (all body materials)
Pressure Control Ranges
■ 1/4 in. tube butt weld inlet, outlet,
■ 0 to 10 psig (0.68 bar) through
and gauge ports (316 SS body
0 to 500 psig (34.4 bar)
material only)
■ 1/4 in. VCR inlet, outlet, and gauge
ports (316 SS body material only)

Materials of Construction 316 SS Brass CW721R


Cover Component Material
Stem nut Knob handle, cover Nylon with 316 SS insert
316 SS (0 to 500 psig range)
Spring button
Stem Zinc-plated steel (all other ranges)
Knob handle
Spring stabilizer➀ 301 SS
Spring 316 SS (0 to 10 through
stabilizer Spring button 0 to 50 psig control ranges)
Range spring
Zinc-plated steel (0 to 100 through
Stop plate 0 to 500 psig control ranges)
Range spring
Stem, stem nut,
Cap ring cap ring, stop plate, 316 SS
Body cap body cap, panel nuts➁
VCR nuts➁ 316 SS —
Diaphragm Seat
Nonwetted lubricant Hydrocarbon-based
Seat retainer Seat retainer 316 SS
Retainer seal Retainer seal PCTFE or PEEK
Seat Fluorocarbon FKM or Kalrez
Diaphragm➂ Alloy X-750
Inlet Outlet
REGULATORS

Body 316 SS Brass CW721R


K SERIES

Tube butt weld ports,➁


316L SS —
Body VCR gland ports➁
Wetted lubricant PTFE-based
Wetted components listed in italics.
➀ Not included in regulators with 0 to 500 psig (0 to 34.4 bar) control range.
➁ Not shown.
➂ Regulators with control ranges higher than 0 to 100 psig (0 to 6.8 bar) are
assembled with two diaphragms.
Pressure Regulators—K Series 25

Dimensions
Dimensions, in inches (millimeters), are for reference only and are subject to change. Tube Butt
Weld Ports
Panel 0.39 (10.0) thick maximum with 2 lock nuts
Panel 0.63 (16.0) thick maximum with 1 lock nut 0.84
Panel cutout 1.38 (35.0) dia (21.3)

3.00
(76.2)
2.13 2.16
(54.0) (55.0)
0.75 VCR Ports
dia (19.0)
dia

0.84
0.75 (21.3)
(19.0)
4.61 Mounting holes 5.00 3.70
(117) 10-32, 0.33 deep (127) (94.0)
(M5 × 0.8, 8.5 deep)

Ordering Information
Build a KBP series regulator ordering number by combining the designators in the sequence shown below.

4 5 6 7 8 9 10 11 12 13 14 15 16
KBP 1 F 0 D 4 A 5 A 2 0 0 0 0
4 Body Material 8 Ports 12 Handle, Mounting
1 = 316 SS 4 = 1/4 in. female NPT 2 = Knob
2 = Brass CW721R T = 1/4 in. × 0.035 in. tube butt weld➀ 3 = 316 SS antitamper nut
A = 316 SS, ASTM G93 Level E-cleaned V = 1/4 in. VCR gland, no nuts➀➁ 6 = Knob, panel mount
B = Brass, ASTM G93 Level E-cleaned X = 1/4 in. rotatable female VCR fitting➀ 7 = 316 SS antitamper nut, panel mount
C = 316 SS, SC-11–cleaned Y = 1/4 in. rotatable male VCR fitting➀ For knob handle color options, see
D = Brass, SC-11–cleaned ➀ Available only with 316 SS body material in A page 56.
port configuration. Not available ASTM G93
Level E-cleaned.
5 Pressure Control Range 13 Valves
➁ For use with VCR split-nuts, which can be
C = 0 to 10 psig (0 to 0.68 bar) ordered separately. See the Swagelok VCR 0 = No valves
D = 0 to 25 psig (0 to 1.7 bar) Metal Gasket Face Seal Fittings catalog
(MS‑01-24).
E = 0 to 50 psig (0 to 3.4 bar)
14 Cylinder Connections
F = 0 to 100 psig (0 to 6.8 bar)
9 Seat, Seal Material 0 = No connections
G = 0 to 250 psig (0 to 17.2 bar)
J = 0 to 500 psig (0 to 34.4 bar) A = Fluorocarbon FKM, PCTFE
B = Kalrez, PCTFE 15 Gauges
C = Fluorocarbon FKM, PEEK 0 = No gauges
6 Maximum Inlet Pressure
D = Kalrez, PEEK For inlet gauge options, see page 54.
0 =Not applicable (equal to pressure
control range)
10 Flow Coefficient (Cv) 16 Options
5 = 0.20 0 = No options
7 Port Configuration
A, D, G, V
11 Sensing Mechanism, Vent
See Port Configurations, page 52.
A = Alloy X-750 diaphragm, no vent
E =Alloy X-750 diaphragm, captured
vent, no self vent REGULATORS
K SERIES
26 Pressure Regulators and Filters

High-Flow, High-Sensitivity Diaphragm-Sensing


Back-Pressure Regulators (KFB Series)
The KFB series regulator is designed to maintain back-pressure control in high-flow
applications with a Cv of 1.0.

Features Technical Data


■ Large-diameter convoluted, Maximum Inlet Pressure
nonperforated diaphragm for ■ Equal to pressure control range
increased pressure sensitivity
Pressure Control Ranges
■ Metal-to-metal diaphragm seal
■ 0 to 10 psig (0.68 bar) through
0 to 250 psig (17.2 bar)
Flow Coefficient (Cv )
■ 1.0
See page 49 for flow graphs.
Maximum Operating Temperature
■ 176°F (80°C) with PCTFE retainer seal
■ 392°F (200°C) with PEEK retainer seal
Weight
■ 4.4 lb (2.0 kg)
Ports
■ 1/2 in. female NPT inlet and outlet;
1/4 in. female NPT gauge port

Materials of Construction Component Material


Knob handle, cover Nylon with 316 SS insert
Cover 316 SS (0 to 250 psig range)
Stem nut Spring button
Zinc-plated steel (all other ranges)
Stem Spring stabilizer➀ 301 SS
316 SS (0 to 10 and
Knob
Spring 0 to 25 psig control ranges)
handle Range spring
Zinc-plated steel (0 to 50 through
stabilizer
0 to 250 psig control ranges)
Spring button
Stop plate Stem, stem nut, cap
ring, stop plate, body 316 SS
Range spring cap, panel nuts➁
Cap ring
Body cap Nonwetted lubricant Hydrocarbon-based
Diaphragm Body, seat retainer 316 SS
Seat Retainer seal PCTFE or PEEK
Seat Fluorocarbon FKM
Seat retainer
Diaphragm➂ Alloy X-750
Retainer seal Wetted lubricant PTFE-based
Wetted components listed in italics.
REGULATORS

➀ N
 ot included in regulators with 0 to 250 psig (0 to 17.2 bar)
Inlet Outlet
K SERIES

control range.
➁ N
 ot shown.
➂ Regulators with control range 0 to 250 psig (0 to 17.2 bar) are
assembled with two diaphragms.

Body
Pressure Regulators—K Series 27

Dimensions
Dimensions, in inches (millimeters), are for reference only and are subject to change.

Panel 0.39 (10.0) thick maximum with 2 lock nuts


Panel 0.63 (16.0) thick maximum with 1 lock nut
Panel cutout 1.38 (35.0) dia

2.13 3.15
(54.0) (80.0) 0.75
dia dia (19.0)

0.96 Mounting holes


(24.5) 10-32, 0.33 deep
5.00 (M5 × 0.8, 8.5 deep) 5.39
(127) (137)

Ordering Information
Build a KFB series regulator ordering number by combining the designators in the sequence shown below.

4 5 6 7 8 9 10 11 12 13 14 15 16
KFB 1 F 0 D 8 A 8 A 1 0 0 0 0

4 Body Material 8 Ports 12 Handle, Mounting


1 = 316 SS 8 =1/2 in. female NPT inlet and outlet; 2 = Knob
A = 316 SS, ASTM G93 Level E-cleaned 1/4 in. female NPT gauge port 3 = 316 SS antitamper nut
6 = Knob, panel mount
5 Pressure Control Range 9 Seat, Seal Material 7 = 316 SS antitamper nut, panel mount
C = 0 to 10 psig (0 to 0.68 bar) A = Fluorocarbon FKM, PCTFE For knob handle color options, see
D = 0 to 25 psig (0 to 1.7 bar) C = Fluorocarbon FKM, PEEK page 56. 
E = 0 to 50 psig (0 to 3.4 bar)
F = 0 to 100 psig (0 to 6.8 bar) 10 Flow Coefficient (Cv) 13 Valves
G = 0 to 250 psig (0 to 17.2 bar) 8 = 1.0 0 = No valves

6 Maximum Inlet Pressure 11 Sensing Mechanism, Vent 14 Cylinder Connections


0 =Not applicable (equal to pressure A = Alloy X-750 diaphragm, no vent 0 = No connections
control range) E =Alloy X-750 diaphragm, captured
vent, no self vent 15 Gauges
7 Port Configuration 0 = No gauges
A, D, G, V For inlet gauge options, see page 54.
See Port Configurations, page 52.
16 Options
0 = No options

REGULATORS
K SERIES
28 Pressure Regulators and Filters

Compact Piston-Sensing
Back-Pressure Regulators (KCB Series)
The KCB series provides high sensitivity back-pressure control of sampling
conditioning systems. It is ideally suited for use in portable or laboratory analytical
systems as well as being embedded in the instrument bays of OEM equipment or
sampling cabinets.

Features Technical Data


■ Low internal volume Maximum Inlet Pressure
■ Fully contained piston ■ Equal to pressure control range
■ Excellent flow characteristics with Pressure Control Ranges
a Cv of 0.20 ■ 0 to 10 psig (0.68 bar) through
■ ANSI/ISA 76.00.02-compliant 0 to 375 psig (25.8 bar)
modular platform component Flow Coefficient (Cv )
(MPC) configuration available
■ 0.20
See page 49 for flow graphs.
■ 0.10 also available with MPC platform
Maximum Operating Temperature
■ 176°F (80°C) with PCTFE retainer seal
■ 392°F (200°C) with PEEK retainer seal
Weight
■ 1.0 lb (0.5 kg)
Ports
■ 1/8 in. female NPT inlet and outlet(s)
■ MPC platform

Materials of Construction Component Material


Thumbwheel handle Anodized aluminum
Thumbwheel
Stem nut Knob handle,➀ cover➀ Nylon with 316 SS insert
handle
Spring button Zinc-plated steel
Stem Spring button Spring stabilizer 301 SS
316 SS (0 to 10 through 0 to 50 and
Spring Range spring 0 to 375 psig control ranges)
Range spring
stabilizer Zinc-plated steel
(all other control ranges)
Body cap
Stem, stem nut,
316 SS
Seat body cap, panel nuts➀
Nonwetted lubricant Hydrocarbon-based
Piston seal
Body, seat retainer, piston 316 SS
Piston Seat retainer Seat, piston seal Fluorocarbon FKM or Kalrez
Retainer seal Retainer seal PCTFE or PEEK
REGULATORS

Wetted lubricant PTFE-based


K SERIES

Wetted components listed in italics.


Inlet Outlet ➀ Not shown.

Body
Pressure Regulators—K Series 29

Dimensions
Dimensions, in inches (millimeters), are for reference only and are subject to change.

Panel 0.50 (12.7) thick


maximum between two nuts
Panel cutout 1.38 (35.0) dia

1.81 1.49 1.26


(46.0) (37.8) (32.0)
dia dia dia

1.24
(31.4)
0.28
(7.0)
3.64
(92.5) Mounting holes
10-32, 0.33 deep
(M5 × 0.8, 8.5 deep) 3.31
(84.0)

Ordering Information
Build a KCB series regulator ordering number by combining the designators in the sequence shown below.

4 5 6 7 8 9 10 11 12 13 14 15 16
KCB 1 F 0 D 2 A 5 P 1 0 0 0 0

4 Body Material 8 Ports 13 Valves


1 = 316 SS 2 = 1/8 in. female NPT 0 = No valves
A = 316 SS, ASTM G93 Level E-cleaned M = MPC platform
C = 316 SS, SC-11–cleaned 14 Cylinder Connections
9 Seat, Retainer Seal Material 0 = No connections
5 Pressure Control Range A = Fluorocarbon FKM, PCTFE
C = 0 to 10 psig (0 to 0.68 bar) B = Kalrez, PCTFE 15 Gauges
D = 0 to 25 psig (0 to 1.7 bar) C = Fluorocarbon FKM, PEEK 0 = No gauges
E = 0 to 50 psig (0 to 3.4 bar) D = Kalrez, PEEK For inlet gauge options, see page 54.
F = 0 to 100 psig (0 to 6.8 bar)
G = 0 to 250 psig (0 to 17.2 bar) 10 Flow Coefficient (Cv) 16 Options
H = 0 to 375 psig (0 to 25.8 bar) 4 = 0.10 (MPC platform only) 0 = No options
5 = 0.20 (1/8 in. female NPT ports only)
6 Maximum Inlet Pressure
0 =Not applicable (equal to pressure 11 Sensing Mechanism
control range) P = 316 SS piston

7 Port Configuration 12 Handle, Mounting


A, D, G, V, 7, 8 1 = Thumbwheel➀
See Port Configurations, page 52. 2 = Knob
3 = 316 SS antitamper nut
5 = Thumbwheel, panel mount➀
6 = Knob, panel mount REGULATORS
7 = 316 SS antitamper nut, panel mount
K SERIES

For knob handle color options, see


page 56.
➀ Not available with 0 to 375 psig (0 to 25.8 bar)
pressure control range.
30 Pressure Regulators and Filters

Medium- to High-Pressure Piston-Sensing


Back-Pressure Regulators (KPB Series)
The KPB series provides back-pressure control in gas or liquid applications. This
compact and lightweight regulator provides an ideal pressure-control solution
within high-density compact OEM equipment, as well as other applications.

Features Technical Data


■ Integral high-pressure overrange Maximum Inlet Pressure
protection ■ Equal to pressure control range
■ Lightweight, compact design Pressure Control Ranges
■ 0 to 1000 psig (68.9 bar) through
0 to 4000 psig (275 bar)
Flow Coefficient (Cv )
■ 0.06 and 0.2
See page 50 for flow graphs.
Maximum Operating Temperature
■ 176°F (80°C) with PCTFE seat
■ 392°F (200°C) with PEEK seat
Weight
■ 2.5 lb (1.2 kg)
Ports
■ 1/4 in. female NPT inlet, outlet, and
gauge ports

Materials of Construction Component Material


Cover Knob handle, cover Nylon with 316 SS insert
Stem nut
316 SS (0 to 500 psig range)
Spring button
Stem Zinc-plated steel (all other ranges)
Knob handle Spring stabilizer➀ 301 SS
Spring
316 SS
stabilizer Spring button Range spring (0 to 3000 and 0 to 4000 psig range)
Range spring Poppet Zinc-plated steel (all other ranges)
retainer Stem, stem nut,
Body cap cap ring, body cap, 316 SS
Piston seal panel nuts➁
Poppet spring and spring
Nonwetted lubricant Hydrocarbon-based
Piston seal Body, seat retainer,
Piston
retainer seat support,
316 SS
Piston guide Cap ring
poppet retainer,
piston, piston guide
Poppet
Body seal Seat,
PCTFE or PEEK
Seat retainer and spring seat retainer seal
Seat Piston seal retainer PEEK
REGULATORS

Seat retainer Poppet S17400 SS


K SERIES

seal Seat support


Poppet spring 302 SS
Inlet Outlet Piston seal, body seal PTFE
Piston seal spring,
Elgiloy
body seal spring
Wetted lubricant PTFE-based
Body Wetted components listed in italics.
➀ Not included in regulators with 0 to 3000 psig (0 to 206 bar) and 0 to
4000 psig (0 to 275 bar) control ranges.
➁ Not shown.
Pressure Regulators—K Series 31

Dimensions
Dimensions, in inches (millimeters), are for reference only and are subject to change.
Panel 0.39 (10.0) thick maximum with 2 lock nuts
Panel 0.63 (16.0) thick maximum with 1 lock nut
Panel cutout 1.38 (35.0) dia

2.13 2.16 0.75


(54.0) (55.0) (19.0)
dia dia

0.75
(19.0)
5.00 Mounting holes 5.00
(127) 10-32, 0.33 deep (127)
(M5 × 0.8, 8.5 deep)

Ordering Information
Build a KPB series regulator ordering number by combining the designators in the sequence shown below.

4 5 6 7 8 9 10 11 12 13 14 15 16
KPB 1 L 0 A 4 2 2 P 2 0 0 0 0

4 Body Material 8 Ports 13 Valves


1 = 316 SS 4 = 1/4 in. female NPT 0 = No valves
A = 316 SS, ASTM G93 Level E-cleaned
9 Seat, Seal Material 14 Cylinder Connections
5 Pressure Control Range 1 = PCTFE 0 = No connections
L = 0 to 1000 psig (0 to 68.9 bar) 2 = PEEK
N = 0 to 2000 psig (0 to 137 bar) 15 Gauges
P = 0 to 3000 psig (0 to 206 bar) 10 Flow Coefficient (Cv) 0 = No gauges
S = 0 to 4000 psig (0 to 275 bar) 2 = 0.06 For inlet gauge options, see page 54.
5 = 0.20
6 Maximum Inlet Pressure 16 Options
0 =Not applicable (equal to pressure 11 Sensing Mechanism 0 = No options
control range) P = 316 SS piston

7 Port Configuration 12 Handle, Mounting


A, D, G, V 2 = Knob
See Port Configurations, page 52. 3 = 316 SS antitamper nut
6 = Knob, panel mount
7 = 316 SS antitamper nut, panel mount
For knob handle color options, see
page 56.

REGULATORS
K SERIES
32 Pressure Regulators and Filters

High-Pressure Piston-Sensing
Back-Pressure Regulators (KHB Series)
The KHB series provides control of back pressures up to 10 000 psig (689 bar) with
high sensitivity across the control range.

Features Technical Data


■ Thrust roller bearing eases operation Maximum Inlet Pressure
■ Panel-mounting configuration ■ Equal to pressure control range
available Pressure Control Ranges
■ 0 to 500 psig (34.4 bar) through
100 to 10 000 psig (6.8 to 689 bar)
Flow Coefficient (Cv )
■ 0.06 and 0.25
See page 51 for flow graphs.
Maximum Operating Temperature
■ 212°F (100°C)
Weight
■ 5.7 lb (2.6 kg)
Ports
■ 1/4 in. female NPT inlet, outlet, and
gauge ports

Materials of Construction Component Material


Knob handle, cover Nylon with 316 SS insert
Knob handle retainer Cover Spring buttons,
upper spring button
Knob handle set screw, 316 SS
Thrust roller knob handle retainer,
bearing stem nuts, body cap
Upper spring Stem CZ114 bronze
Upper spring button Thrust roller bearing Hardened carbon steel
button set screw
Range spring Chrome vanadium steel
Stem
Range spring Piston seal backup ring PEEK
Stem nuts Nonwetted lubricant Hydrocarbon-based
Body cap
Piston Body, poppet retainer,
Piston seal seat retainer, seat support, 316 SS
Piston seal piston, piston guide
Lower spring
button backup ring Seat PEEK or 316 SS
Poppet retainer seal PEEK
Piston guide Poppet retainer
seal Poppet S17400 SS
Poppet spring Poppet spring 302 SS
Poppet retainer
REGULATORS

Piston seal, body seal,


K SERIES

Body seal Fluorocarbon FKM


Seat retainer seat support seal
Poppet Wetted lubricant PTFE-based
Seat
Wetted components listed in italics.
Seat support
seal Seat support
Inlet Outlet

Body
Pressure Regulators—K Series 33

Dimensions
Dimensions, in inches (millimeters), are for reference only and are subject to change.
Clearance hole dia 0.31 (8.0)
Panel-mount
assembly shown
Panel cutout minimum dia 2.25 (57.2)

2.20 2.83
0.75 3.19 (56.0) (72.0)
(19.0) (81.0)
dia dia

0.96
(24.5)
Mounting holes
10-32, 0.33 deep
(M5 × 0.8, 8.5 deep) 3.94 to 5.20
(100 to 132)
allowable
7.36
(187)

Ordering Information
Build a KHB series regulator ordering number by combining the designators in the sequence shown below.

4 5 6 7 8 9 10 11 12 13 14 15 16
KHB 1 T 0 D 4 C 2 P 2 0 0 0 0

4 Body Material 8 Ports 13 Valves


1 = 316 SS 4 = 1/4 in. female NPT 0 = No valves
A = 316 SS, ASTM G93 Level E-cleaned
9 Seat, Piston/Body/Seat Support 14 Cylinder Connections
5 Pressure Control Range Seal Material 0 = No connections
J = 0 to 500 psig (0 to 34.4. bar) C = PEEK, fluorocarbon FKM
K = 0 to 750 psig (0 to 51.6 bar) J = 316 SS, fluorocarbon FKM➀ 15 Gauges
T = 10 to 1500 psig (0.68 to 103 bar) ➀ Not suitable for gas service. 0 = No gauges
U = 15 to 2500 psig (1.0 to 172 bar) For inlet gauge options, see page 54.
V = 25 to 3600 psig (1.7 to 248 bar) 10 Flow Coefficient (Cv)
W = 50 to 6000 psig (3.4 to 413 bar) 2 = 0.06 16 Options
X = 100 to 10 000 psig (6.8 to 689 bar) 6 = 0.25 0 = No options

6 Maximum Inlet Pressure 11 Sensing Mechanism


0 =Not applicable (equal to pressure P = 316 SS piston
control range)
12 Handle, Mounting
7 Port Configuration 2 = Knob
A, D, G, V 6 = Knob, panel mount
See Port Configurations, page 52. For knob handle color options, see
page 56.
REGULATORS
K SERIES
34 Pressure Regulators and Filters

Gas Cylinder Changeover Regulator (KCM Series)


The KCM series is a two-stage gas delivery system that ensures continuous flow of
gases in critical applications. When one supply drops below the changeover pressure,
the selector regulator automatically switches the gas feed from the depleted supply to
an alternate supply. The automatic operation of the KCM series eliminates costly system
downtime and maintenance expense of continuously monitoring the gas supply.

Features Nominal Changeover Pressures


■ Convoluted, nonperforated ■ 100, 250, and 500 psig
diaphragm for strength and improved (6.8, 17.2, and 34.4 bar)
pressure response Flow Coefficient (Cv )
■ Metal-to-metal diaphragm seals on ■ 0.06
all stages
Supply-Pressure Effect
■ Supply-pressure effect of
approximately 0.01 % Pressure Control Range
■ Bracket mount Up to 250 psig
100 psig (17.2 bar)
Flow Shown with Swagelok tube fittings,
(6.8 bar) and Higher
Technical Data Coefficient not included.
(Cv ) Supply Pressure Effect, %
Maximum Inlet Pressure➀
0.06 0.01 0.02 Weight
■ 4351 psig (300 bar) with PEEK seat
■ 7.25 lb (3.3 kg)
■ 3600 psig (248 bar) Maximum Operating Temperature
➀ Cylinder Connections and Hose accessories Ports
■ 176°F (80°C) with PCTFE seat
may limit inlet pressure ratings, see pages ■ 1/4 in. female NPT inlet, outlet, and
53 and 56. ■ 392°F (200°C) with PEEK seat
gauge ports
Pressure Control Ranges ■ 212°F (100°C) with PEEK seat and
■ 0 to 10 psig (0.68 bar) through maximum inlet pressure greater than
0 to 500 psig (34.4 bar) 3600 psig (248 bar)

Operation Line regulator To system Materials of Construction


The KCM series can The KCM series gas changeover uses Swagelok KPR
be ordered to switch series pressure-reducing regulators. For more information,
from one supply to see General-Purpose Diaphragm Sensing, Pressure-
another at one of Reducing Regulators (KPR Series), page 6.
three different inlet The table below lists additional components not shown in the
pressures—100, 250, KPR series section.
Selector
and 500 psig (6.8,
regulator
17.2, and 34.4 bar)— Component Material
called changeover 316 SS
Supply 1 Supply 2 Interstage fitting
pressures. with PTFE tape
The selector regulator Line-regulator
Aluminum
mounting block
(first stage) is factory-set to reduce the supply pressure to
the nominal changeover pressure ordered. The line regulator Line-regulators
mounting screws, 316 SS
(second stage) can be adjusted with the handle to achieve mounting bracket
the required system pressure. This two-stage arrangement
Wetted components listed in italics.
minimizes the supply-pressure effect caused by depleting
gas supplies (cylinders, tank farm, etc.).
Approximate Supply Depletion Pressures
When one supply drops below the changeover pressure,
REGULATORS
K SERIES

the selector regulator automatically switches the gas feed Supply 1


from the depleted supply to an alternate supply. If both Nominal Supply 1 (300 bar) Supply 2
supplies drop below the changeover pressure, the assembly Changeover Depletion Depletion Depletion
Pressure Pressure Pressure Pressure
functions as a single-stage regulator, depleting both supplies psig (bar) psig (bar) psig (bar) psig (bar)
at the same time. See the Approximate Supply Depletion 100 (6.8) 150 (10.3) 180 (12.4) 90 (6.2)
Pressures table at right for pressures at which this occurs.
250 (17.2) 300 (20.6) 320 (22.1) 230 (15.8)
500 (34.4) 500 (34.4) 530 (36.6) 450 (31.0)
The Swagelok KCA series continuous gas delivery system
is a panel-mounted gas changeover assembly that can be Supply 2 can deplete below some of the available pressure control range
limits. Setting the line regulator near the nominal changeover pressure will
configured for many applications. For more information, cause flow to the system to decrease or stop as the supply nears depletion.
see the Swagelok KCA Series Continuous Gas Delivery
System catalog, MS-18-01.
Pressure Regulators—K Series 35

Dimensions
Dimensions, in inches (millimeters), are for reference only and are subject to change.

2 mounting holes,
0.50 (12.7) dia
Outlet Outlet
9.65
(245)
6.30 5.00
(160) (127)

4 mounting holes,
1.57 2.48 Inlet 2.99 Inlet 0.25 (6.4) dia
(40.0) (63.0) (76.0)
8.46 7.68
(215) (195)

Ordering Information
Build a KCM series regulator ordering number by combining the designators in the sequence shown below.

4 5 6 7 8 9 10 11 12 13 14 15 16
KCM 1 F F B 4 1 2 A D 0 0 1 0
4 Body Material 7 Port Configuration 13 Isolation and Relief Valves
1 = 316 SS B, C, L 0 = No valves
A = 316 SS, ASTM G93 Level E-cleaned See Port Configurations, below. For isolation and relief valve options,
see page 54.
5 Pressure Control Range 8 Ports
C = 0 to 10 psig (0 to 0.68 bar) 4 = 1/4 in. female NPT 14 Cylinder Connections
0 = No connections
D = 0 to 25 psig (0 to 1.7 bar)
9 Seat Material Cylinder connections available only with
E = 0 to 50 psig (0 to 3.4 bar)
1 = PCTFE hose option. For cylinder connection
F = 0 to 100 psig (0 to 6.8 bar)
2 = PEEK options and pressure ratings, see page
G = 0 to 250 psig (0 to 17.2 bar)➀
J = 0 to 500 psig (0 to 34.4 bar)➁ 53.
10 Flow Coefficient (Cv)
➀ Not available with 100 psig (6.8 bar) 2 = 0.06 15 Gauge Scale
changeover pressure.
1 = psig (bar) (North America only)
➁ Only available with 500 psig (34.4 bar)
changeover pressure. 11 Sensing Mechanism, Vent 2 = bar (psig)
A = Alloy X-750 diaphragm, no vent 3 = psig (bar)
6 Nominal Changeover Pressure➀ C = Alloy X-750 diaphragm, self vent➀ 4 = MPa
E =Alloy X-750 diaphragm, captured 5 = psig (kPa)
F = 100 psig (6.8 bar)
G = 250 psig (17.2 bar) vent, no self vent➀ For more information, see page 54.
J = 500 psig (34.4 bar) F =Alloy X-750 diaphragm, self and
captured vent➀ 16 Options
➀ Self and captured vent options on line 0 = No options
For 4351 psig (300 bar) inlet➁
regulator only. 3 =3 ft, 1/4 in. FX series metal flexible
5 = 100 psig (6.8 bar)
hose, 1/4 in. female NPT inlet➀
6 = 250 psig (17.2 bar) 12 Line Regulator Handle 4 =3 ft, 1/4 in. TH series PTFE-lined,
7 = 500 psig (34.4 bar) D = Knob
REGULATORS

stainless steel braided hose, 1/4 in.


K SERIES
➀ Inlet pressure must exceed changeover
pressure for automatic switching to occur. E = 316 SS antitamper nut female NPT inlet➀
➁ Only available with PEEK seat.
Selector regulator has knob handle. For For hose options and pressure ratings,
knob handle color options, see page 56.  see page 56.
➀ Not available for ASTM G93 Level E-cleaned
regulators.
Port Configurations
Configuration Designator Configuration Designator Configuration Designator

Go/R Go/R Go/R Go Go/R Go/R Go/R Go Go


I I I R II I R I I R I Go = Outlet gauge.
B C L Go/R = Outlet gauge
Inlet from Inlet from Inlet from or relief valve.
selector selector selector R = Relief valve.
regulator regulator regulator
I = Isolation valve.
36 Pressure Regulators and Filters

Steam-Heated Vaporizing, Diaphragm-Sensing


Pressure-Reducing Regulator (KSV Series)
The KSV series is a steam-heated vaporizing regulator with a low internal volume. It
can be used to vaporize liquid samples or to preheat gas samples to prevent them
from condensing.

Features Supply-Pressure Effect


■ Convoluted, nonperforated
Pressure Control Range
diaphragm
Up to 250 psig
■ Metal-to-metal diaphragm seal 100 psig (17.2 bar)
Flow
(6.8 bar) and Higher
■ Low internal volume Coefficient
(Cv ) Supply Pressure Effect, %
Technical Data 0.06 1.0 1.5
Maximum Inlet Pressure 0.20 1.5 2.4
■ 3600 psig (248 bar)
Maximum Steam Pressure
Outlet Pressure Ranges and Temperature
■ 0 to 10 psig (0.68 bar) through ■ 650 psig (44.7 bar) and 500°F (260°C)
0 to 500 psig (34.4 bar)
Maximum Regulator
Flow Coefficient (Cv) Operating Temperature
■ 0.06 or 0.20 ■ 392°F (200°C)
Weight
■ 3.3 lb (1.5 kg)
Ports
■ 1/8 in. female NPT inlet; 1/4 in.
female NPT outlet(s)
■ Steam tube 1/2 in. outside diameter,
0.049 in. wall

Materials of Construction Component Material


Antitamper nut, stem,
cap ring, stop plate, 316 SS
body cap, panel nuts➀
Antitamper nut Body cap
Spring button Zinc-plated steel
Stem Spring stabilizer➁ 301 SS
Spring button
Spring 316 SS or zinc-plated steel,
Range spring
stabilizer Range spring depending on configuration
Nonwetted lubricant Hydrocarbon-based
Stop plate Seat retainer Body, seat retainer,
316 SS
steam tube
Cap ring
Poppet Seat PEEK
Diaphragm Diaphragm,➂
Poppet spring Alloy X-750
poppet spring
Seat
Poppet S17400 SS
Outlet Wetted lubricant PTFE-based
REGULATORS
K SERIES

Wetted components listed in italics.


Body ➀ Not shown.
➁ Not required in all configurations.
➂ Regulators with control ranges higher than 0 to 100 psig (0 to 6.8 bar) are
assembled with two diaphragms.

Steam tube

Inlet
Pressure Regulators—K Series 37

Dimensions
Dimensions, in inches (millimeters), are for reference only and are subject to change.
1.00 1.75
(25.4) (44.5)

0.75 Panel 0.39 (10.0) thick maximum with 2 lock nuts


(19.0)
Panel 0.63 (16.0) thick maximum with 1 lock nut
Panel cutout 1.38 (35.0) dia
2.17
9.02 (55.0)
(229)
dia

0.75
(19.0)
5.20
(132) Mounting holes
10-32, 0.33 deep
(M5 × 0.8, 8.5 deep)

0.50
(12.7)
dia

Ordering Information
Build a KSV series regulator ordering number by combining the designators in the sequence shown below.

4 5 6 7 8 9 10 11 12 13 14 15 16
KSV 1 F R 1 3 2 2 A 3 0 0 0 0
4 Body Material 8 Ports 12 Handle, Mounting
1 = 316 SS 3 =1/8 in. female NPT inlet; 3 = Antitamper nut
A = 316 SS, ASTM G93 Level E-cleaned 1/4 in. female NPT outlet(s) 7 = Antitamper nut, panel mount

5 Pressure Control Range 9 Seat Material 13 Valves


C = 0 to 10 psig (0 to 0.68 bar) 2 = PEEK 0 = No valves
D = 0 to 25 psig (0 to 1.7 bar)
E = 0 to 50 psig (0 to 3.4 bar) 10 Flow Coefficient (Cv) 14 Cylinder Connections
F = 0 to 100 psig (0 to 6.8 bar) 2 = 0.06 0 = No connections
G = 0 to 250 psig (0 to 17.2 bar) 5 = 0.20
J = 0 to 500 psig (0 to 34.4 bar) 15 Gauges
11 Sensing Mechanism, Vent 0 = No gauges
6 Maximum Inlet Pressure➀ A = Alloy X-750 diaphragm, no vent
F = 100 psig (6.8 bar) E =Alloy X-750 diaphragm, captured 16 Options
J = 500 psig (34.4 bar) vent, no self vent 0 = No options
L = 1000 psig (68.9 bar)
R = 3600 psig (248 bar)
➀ For better resolution and control, select a
pressure that closely matches system pressure. REGULATORS
K SERIES

7 Port Configuration Port Configurations


1, 4
Configuration Designator Configuration Designator
See Port Configurations, right.
Inlet in Inlet in
bottom bottom
of body of body
1 4

Steam tubes Steam tubes


38 Pressure Regulators and Filters

Electrically Heated Vaporizing


Pressure-Reducing Regulator (KEV Series)
The KEV series is an electrically Features
heated vaporizing regulator with a ■ Convoluted, nonperforated
low internal volume. It can be used to diaphragm for control ranges up to
vaporize liquid samples or to preheat 500 psig (34.4 bar)
gas samples to prevent them from
■ Stainless steel piston for control
condensing. It features a heating
ranges from 1000 to 3600 psig (68.9
element that is in direct contact with
to 248 bar)
the process fluid for maximum thermal
efficiency and is removable for easy ■ ATEX, IECEx, and CSA certified for
cleaning. The KEV regulator has an critical/hazardous environments
integral temperature controller and is ■ T3 temperature classification for all
rated for use in hazardous areas, as heater ranges
identified below. ■ CE conformity: 89/336/EEC (EMC)
■ Horizontally or vertically mounted
■ One-piece body eliminates potential
leak paths
■ Low-volume vapor chamber for fast
response
■ Heater in direct contact with
process media for maximum thermal
efficiency
■ Removable heater simplifies cleaning
■ Side and base inlet options

Technical Data
Maximum Inlet Pressure Electrical • WARNING
■ 3600 psig (248 bar) ■ Supply—120 and 240 V (ac) (± 10 %), 
Do not alter or disassemble
Pressure Control Ranges 50/60 Hz any of the flameproof
■ 0 to 10 psig (0.68 bar) through ■ Heater ratings—50, 100, 150, joints within the KEV series
and 200 W regulator. Damage to the
0 to 3600 psig (248 bar)
■ Control temperature range—
regulator resulting in affected
Flow Coefficient (Cv) performance and product safety
75 to 380°F (23 to 193°C)
■ 0.02 or 0.06 is possible.
■ Explosive atmosphere/hazardous
Supply-Pressure Effect
location certification: • WARNING
 here is a potential for air to
T
Pressure Control Range ■ A
 TEX (Europe) and IECEx
become trapped within the piping
1000 (international)—Group II, Category
system, creating the possibility of
250 and psig 2G, Ex db IIB+H2 T3 Gb
a combustible mixture. This could
Up to 500 psig (68.9 bar) Ambient temperatures: –4 to
100 psig (17.2 and and occur during system startup or
Flow 140°F (–20 to 60°C)
Coefficient (6.8 bar) 34.4 bar) Higher
shutdown. In order to allow the
■ C
 SA (Canada and U.S.A.)— KEV heater tube to stabilize at
(Cv ) Supply Pressure Effect, %
Class I, Div 1, Groups B, C, and D; ambient temperature, turn off
0.02 0.3 0.5 2.2
T3; CSA Encl Type 4 the power to the regulator during
0.06 1.0 1.5 7.2 Ambient temperatures: –58 to
REGULATORS

system startup and shutdown.


K SERIES

122°F (–50 to 50°C) The amount of time needed for


Weight
■ Side mounted—8.8 lb (4.0 kg) • WARNING the system to reach ambient
conditions depends on several
■ Base mounted—7.7 lb (3.5 kg)
Certification and hazardous type system parameters including, but
protection may be impaired if the not limited to, set point, flow rate,
Ports KEV regulator is used in a manner ambient temperature, and the
■ 1/8 in. female NPT inlet; 1/4 in. female not specified by swagelok. Refer termal properties of the system
NPT outlet to KEV Series Electrically Heated and fluid.
Vaporizing Pressure Reducing
Regulators Instructions for Contact your authorized sales
Use, MS-CRD-KEV1, for correct and service representative for any
method of installation, operation, maintenance or repair beyond the
and use. maintenance of the heater sheath.
Pressure Regulators—K Series 39

Materials of Construction Component Material


Antitamper nut, stem,
cap ring, stop plate,➀
Antitamper nut Body cap body cap, retainer nut, flange, 316 SS
flange bolts, lock nut,
Stem Spring button connector tube, panel nuts➁
Spring Range spring Spring button Zinc-plated steel
stabilizer Spring stabilizer➂ 301 SS
Seat retainer 316 SS or zinc-plated steel,
Stop plate Range spring
depending on configuration
Poppet
Cap ring Connector tube seal Nitrile
Poppet spring Nonwetted lubricant Hydrocarbon-based
Diaphragm
Body Body, seat retainer,
316 SS
Seat heater sheath
Heater sheath Heater sheath seal Alloy 718
Seat PEEK
Diaphragm➀➃ Alloy X-750
Inlet Outlet Poppet S17400 SS
Heater Poppet spring 302 SS
Retainer nut
sheath seal Wetted lubricant PTFE-based
Connector Flange Piston Sensing Components
tube seal (bolts not shown) Piston seal, body seal PTFE
Piston, piston guide 316 SS
Lock nut Piston seal retainer PEEK
Piston seal spring,
Connector Elgiloy
body seal spring
tube
Wetted components listed in italics.
➀ Not included in regulators with piston sensing mechanism.
➁ Not shown.
➂ Not required in all configurations.
➃ Regulators with control ranges 0 to 250 psig (0 to 17.2 bar) and
Piston Sensing Mechanism 0 to 500 psig (0 to 34.4 bar) are assembled with two diaphragms.

Piston seal Piston


and spring
Piston guide

Piston seal Body seal


retainer and spring

Dimensions
Dimensions, in inches (millimeters), are for reference only and Base-Mounted
are subject to change.
5.71
Side-Mounted 5.71 (145)
(145)
REGULATORS
K SERIES

9.76
(248)
5.12
(130) 12.6
5.35 (320)
5.79 (136)
3.74 3.07 (147)
(95.0) (78.0)

3.07
(78.0)
5.55
(141)
0.87
3.60 (22.0)
(91.5)
40 Pressure Regulators and Filters

Ordering Information
Build a KEV series regulator ordering number by combining the designators in the sequence shown below.

4 5 6 7 8 9 10 11 12 13 14 15 16
KEV 1 F R A 3 2 2 A X 0 0 0 G
4 Body Material 7 Port Configuration 13 Valves
1 = 316 SS Side Mount—A, X, 1, 2 0 = No valves
A = 316 SS, ASTM G93 Level E-cleaned Base Mount—A, B, X, Y, Z
See Port Configurations, below. 14 Cylinder Connections
5 Pressure Control Range 0 = No connections
Diaphragm Sensing 8 Ports
C = 0 to 10 psig (0 to 0.68 bar) 3 =1/8 in. female NPT inlet; 15 Gauges
D = 0 to 25 psig (0 to 1.7 bar) 1/4 in. female NPT outlet(s) 0 = No gauges
E = 0 to 50 psig (0 to 3.4 bar)
F = 0 to 100 psig (0 to 6.8 bar) 9 Seat Material 16 Heater, Controller
G = 0 to 250 psig (0 to 17.2 bar) 2 = PEEK 75 to 380°F 75 to 380°F
J = 0 to 500 psig (0 to 34.4 bar) (23 to 193°C), 120 V (23 to 193°C), 240 V
Piston Sensing 10 Flow Coefficient (Cv) G = 50 W 6 = 50 W
L = 0 to 1000 psig (0 to 68.9 bar) 1 = 0.02 H = 100 W 7 = 100 W
M = 0 to 1500 psig (0 to 103 bar) 2 = 0.06 J = 150 W 8 = 150 W
N = 0 to 2000 psig (0 to 137 bar) K = 200 W 9 = 200 W
P = 0 to 3000 psig (0 to 206 bar) 11 Sensing Mechanism
R = 0 to 3600 psig (0 to 248 bar) A =Alloy X-750 diaphragm (outlet
pressures up to 500 psig
6 Maximum Inlet Pressure➀ [34.4 bar])
F = 100 psig (6.8 bar)➁ P =316 SS piston (outlet pressures
J = 500 psig (34.4 bar)➁ above 500 psig [34.4 bar])
L = 1000 psig (68.9 bar)➁
R = 3600 psig (248 bar) 12 Handle, Mounting
➀ For better resolution and control, select a W = Antitamper nut, side mount
pressure that closely matches system pressure.
➁ Available with diaphragm sensing mechanism
X = Antitamper nut, base mount
only.

Port Configurations➀
Outlet and auxiliary ports on the same face.

Side-Mount Side Mount Base- Base Mount


View Mount View
Designator Configuration Designator Configuration
Base inlet

1 Y

Base inlet
Z
2
REGULATORS
K SERIES

A
A

X
➀ Regulator is rotatable B
360° in relation to
terminal box. Aux
Pressure Regulators—K Series 41

K Series Pressure-Reducing Regulator Flow Data


The graphs illustrate the change or “droop” in outlet pressures as the flow rate increases. See the Swagelok Pressure-Reducing
Regulator Flow Curves Technical Bulletin, MS-06-114, for an overview of how to read regulator flow curves and for additional
inlet pressures and flow coefficients

KPR Series
Flow Coefficient 0.06; Flow Coefficient 0.20;
Maximum Inlet Pressure 3600 psig (248 bar) Maximum Inlet Pressure 3600 psig (248 bar)
Pressure Control Ranges Pressure Control Range
0 to 10 psig (0 0 to 25 psig 0 to 25 psig
to 0.68 bar) (0 to 1.7 bar) (0 to 1.7 bar)
Nitrogen Flow, std L/min Nitrogen Flow, std L/min
0 40 80 120 160 200 240 280
25

1.5
Inlet Pressure
Outlet Pressure, psig

Outlet Pressure, psig


20

Outlet Pressure, bar

Outlet Pressure, bar


500 psig (34.4 bar)
Inlet Pressure
15
500 psig (34.4 bar) 1.0 USA - KPR —
100 psig
(6.8 bar)
10
0.5
500 psig
(34.4 bar) 5.0
100 psig 100 psig
(6.8 bar) (6.8 bar)
0
0 2.0 4.0 6.0 8.0 10
Nitrogen Flow, std ft3/min Nitrogen Flow, std ft3/min

Pressure Control Ranges 0 2,0


Pressure
4,0
Control
6,0
Range 8,0 10
0 to 50 psig 0 to 100 psig 0 to 100 psig 25
(0 to 3.4 bar) (0 to 6.8 bar) (0 to 6.8 bar)
1,5
Nitrogen Flow, std L/min Nitrogen Flow, std L/min 20
0 200 400 600 800 1000 0 200 400 600 800
80 80
1,0 15 EURO - KPR
5.0 Inlet Pressure 5.0
Inlet Pressure
2200 psig (151 bar)
Outlet Pressure, psig

Outlet Pressure, psig

2200 psig (151 bar)


Outlet Pressure, bar

Outlet Pressure, bar


60 60 10
100 psig 4.0 4.0
(6.8 bar) 0,5
500 psig 3.0 USA - KPR — 0.06 Cv 5,0
3.0 USA - KPR —
40 (34.4 bar) 40

2.0 02.0
0 40 80 120 160 200 240 280
20 20 500 psig
2200 psig 1.0 100 psig (34.4 bar) 1.0
100 psig (151 bar)
(6.8 bar) 500 psig (6.8 bar)
(34.4 bar)
0 0
0 5.0 10 15 20 25 30 35 40 0 5.0 10 15 20 25 30 35
Nitrogen Flow, std ft3/min Nitrogen Flow, std ft3/min
0.15

Pressure Control Ranges 0 5,0 Pressure


10 15 Control
20 Range
25 30 35
0 5,0 010to 25015psig 20 25 0 to 30 35 40
500 psig 0.10 0 to 500 psig 80 JAPAN - KPR
(0 to 17.2 bar) (0 to 34.4 bar) 80 (0 to 34.4 bar)
5,0
5,0
Nitrogen Flow, std L/min Nitrogen Flow, std L/min
REGULATORS

60
K SERIES
0 400 800 1200 1600 4,0
0.05
4,0 60
400
Inlet Pressure 25 3,0 EURO - KPR
3,0 2200 psig (151 bar) EURO - KPR — 0.06 Cv 40
Outlet Pressure, psig

Outlet Pressure, psig

40
Outlet Pressure, bar

Outlet Pressure, bar

300 Inlet Pressure


20 2,0
2,0 0 40 80 120 1602200200
psig (151
240bar) 280
500 psig
(34.4 bar) 1000 psig 20
(68.9 bar) 20
15 USA -1,0
KPR — 0.06 Cv
200
1,0

10 0
0 0 0 200 400 600 800
1000 500 psig 2.0 4.0 6.0 8.0 10
200 400 600 800 1000
(34.4 bar) 1000 psig 2200 psig 5.0 1000 psig
(68.9 bar) 500 psig
(151 bar) (34.4 bar) (68.9 bar)
1.5 0.15
0
0 10 20 30 40 50 60 70
Nitrogen Flow, std ft3/min Nitrogen Flow, std ft3/min
1.0
0.5 0.10 CHINA - KPR
0.5

0.4
0.4 0 10 20 30 40 50 60 70
0.5 0.05
400
0.3
JAPAN - KPR — 0.06 Cv JAPAN - KPR
25
0.3
42 Pressure Regulators and Filters

K Series Pressure-Reducing Regulator Flow Data


The graphs illustrate the change or “droop” in outlet pressures as the flow rate increases.

KCY Series
Flow Coefficient 0.06; Flow Coefficient 0.20;
Maximum Inlet Pressure 3600 psig (248 bar) Maximum Inlet Pressure 3600 psig (248 bar)
Pressure Control Ranges Pressure Control Range
0 to 10 psig 0 to 25 psig 0 to 25 psig
(0 to 0.68 bar) (0 to 1.7 bar) (0 to 1.7 bar)
Nitrogen Flow, std L/min Nitrogen Flow, std L/min
Outlet Pressure, psig

Outlet Pressure, psig


Outlet Pressure, bar

Outlet Pressure, bar


Inlet Pressure Inlet Pressure
2200 psig 2200 psig
(151 bar) (151 bar)

600, 1000 psig 600 psig


(41.3, 68.9 bar) (41.3 bar)
1000 psig
2200 psig (68.9 bar)
(151 bar)

Nitrogen Flow, std ft3/min Nitrogen Flow, std ft3/min

Pressure Control Ranges Pressure Control Range


0 to 50 psig 0 to 100 psig 0 to 100 psig
(0 to 3.4 bar) (0 to 6.8 bar) (0 to 6.8 bar)
Nitrogen Flow, std L/min Nitrogen Flow, std L/min

2200 psig
(151 bar)
Outlet Pressure, psig

Outlet Pressure, psig


Outlet Pressure, bar

Outlet Pressure, bar


Inlet Pressure
600 psig Inlet Pressure
(41.3 bar) 1000 psig 2200 psig
(68.9 bar) (151 bar)
600 psig
(41.3 bar)
2200 psig
600 psig (151 bar)
(41.3 bar)
1000 psig 1000 psig
(68.9 bar) (68.9 bar)

Nitrogen Flow, std ft3/min Nitrogen Flow, std ft3/min

Pressure Control Ranges Pressure Control Range


0 to 250 psig 0 to 500 psig 0 to 500 psig
(0 to 17.2 bar) (0 to 34.4 bar) (0 to 34.4 bar)
Nitrogen Flow, std L/min Nitrogen Flow, std L/min
0 400 800 1200 1600
400
REGULATORS

25
K SERIES

Outlet Pressure, psig

Outlet Pressure, psig


Outlet Pressure, bar

Outlet Pressure, bar

300
2200 psig 20
Inlet Pressure (151 bar)
600 psig
15
(41.3 bar) 200
1000 psig Inlet Pressure
(68.9 bar) 2200 psig 10
600 psig
(41.3 bar) (151 bar)
600 psig 2200 psig 100
(41.3 bar) 1000 psig (151 bar) 5.0
1000 psig
(68.9 bar) (68.9 bar)
0
0 10 20 30 40 50 60
Nitrogen Flow, std ft3/min Nitrogen Flow, std ft3/min

0 10 20 30 40 50 60
400
25

300
20
Pressure Regulators—K Series 43

K Series Pressure-Reducing Regulator Flow Data


The graphs illustrate the change or “droop” in outlet pressures as the flow rate increases.

KLF Series
Flow Coefficient 0.02; Flow Coefficient 0.06;
Maximum Inlet Pressure 3600 psig (248 bar) Maximum Inlet Pressure 3600 psig (248 bar)
Pressure Control Range Pressure Control Ranges
0 to 10 psig 0 to 10 psig 0 to 25 psig
(0 to 0.68 bar) (0 to 0.68 bar) (0 to 1.7 bar)
Nitrogen Flow, std L/min Nitrogen Flow, std L/min
Outlet Pressure, psig

Outlet Pressure, psig


Outlet Pressure, bar

Outlet Pressure, bar


Inlet Pressure
Inlet Pressure 2200 psig (151 bar)
500 psig (34.4 bar) 100 psig
100 psig
(6.8 bar) (6.8 bar)
500 psig
(34.4 bar)
2200 psig
100 psig (151 bar) 500 psig
(6.8 bar) (34.4 bar)

Nitrogen Flow, std ft3/min Nitrogen Flow, std ft3/min

Pressure Control Range Pressure Control Ranges


0 to 50 psig 0 to 50 psig 0 to 100 psig
(0 to 3.4 bar) (0 to 3.4 bar) (0 to 6.8 bar)
Nitrogen Flow, std L/min Nitrogen Flow, std L/min
Outlet Pressure, psig

Outlet Pressure, psig


Outlet Pressure, bar

Outlet Pressure, bar


100 psig Inlet Pressure
Inlet Pressure (6.8 bar) 2200 psig (151 bar)
2200 psig (151 bar)
500 psig
100 psig 500 psig (34.4 bar)
(6.8 bar) (34.4 bar)

2200 psig
100 psig (151 bar)
(6.8 bar) 500 psig
(34.4 bar)

Nitrogen Flow, std ft3/min Nitrogen Flow, std ft3/min

Pressure Control Range Pressure Control Range


0 to 250 psig 0 to 250 psig
(0 to 17.2 bar) (0 to 17.2 bar)
Nitrogen Flow, std L/min Nitrogen Flow, std L/min
REGULATORS
K SERIES
Outlet Pressure, psig

Outlet Pressure, psig


Outlet Pressure, bar

Outlet Pressure, bar

500 psig Inlet Pressure


(34.4 bar) 2200 psig
(151 bar)
500 psig 1000 psig
Inlet Pressure (68.9 bar)
(34.4 bar) 2200 psig
1000 psig
(68.9 bar) (151 bar)

Nitrogen Flow, std ft3/min Nitrogen Flow, std ft3/min


44 Pressure Regulators and Filters

K Series Pressure-Reducing Regulator Flow Data


The graphs illustrate the change or “droop” in outlet pressures as the flow rate increases.

KHF Series KPF Series


Flow Coefficient 1.0; Flow Coefficient 1.0;
Maximum Inlet Pressure 3600 psig (248 bar) Maximum Inlet Pressure 6000 psig (413 bar)
Pressure Control Ranges Pressure Control Ranges
0 to 10 psig 0 to 25 psig 0 to 1000 psig 0 to 2000 psig
(0 to 0.68 bar) (0 to 1.7 bar) (0 to 68.9 bar) (0 to 137 bar)
Nitrogen Flow, std L/min Nitrogen Flow, std L/min

Inlet Pressure
3000 psig (206 bar)
Outlet Pressure, psig

Outlet Pressure, psig


Outlet Pressure, bar

Outlet Pressure, bar


Inlet Pressure
2200 psig 5000 psig 2000 psig
(151 bar) (344 bar) (137 bar)

100 psig 500 psig 3000 psig (206 bar)


100 psig (34.4 bar)
(6.8 bar) (6.8 bar)
1000 psig (68.9 bar)
500 psig
(34.4 bar)

Nitrogen Flow, std ft3/min Nitrogen Flow, std ft3/min

Pressure Control Ranges Pressure Control Ranges


0 to 50 psig 0 to 100 psig 0 to 3000 psig 0 to 4000 psig
(0 to 3.4 bar) (0 to 6.8 bar) (0 to 206 bar) (0 to 275 bar)
Nitrogen Flow, std L/min Nitrogen Flow, std L/min

Inlet Pressure

Outlet Pressure, bar


Inlet Pressure 5000 psig (344 bar)
Outlet Pressure, psig

Outlet Pressure, psig

2200 psig
Outlet Pressure, bar

(151 bar) 3500 psig


(241 bar)

2200 psig
(151 bar) 500 psig 1000 psig
(34.4 bar) (68.9 bar)
5000 psig
(344 bar)
500 psig
100 psig (34.4 bar)
3000 psig
(6.8 bar) (206 bar)

Nitrogen Flow, std ft3/min Nitrogen Flow, std ft3/min

Pressure Control Range


0 to 250 psig
(0 to 17.2 bar)
Nitrogen Flow, std L/min
REGULATORS
K SERIES

Outlet Pressure, psig

Outlet Pressure, bar

Inlet Pressure
2200 psig
(151 bar)

500 psig
(34.4 bar) 1000 psig
(68.9 bar)

Nitrogen Flow, std ft3/min


Pressure Regulators—K Series 45

K Series Pressure-Reducing Regulator Flow Data


The graphs illustrate the change or “droop” in outlet pressures as the flow rate increases.

KCP Series
Flow Coefficient 0.06; Maximum Inlet Pressure 3600 psig (248 bar)

Pressure Control Ranges Pressure Control Ranges


0 to 10 psig 0 to 25 psig 0 to 50 psig 0 to 100 psig
(0 to 0.68 bar) (0 to 1.7 bar) (0 to 3.4 bar) (0 to 6.8 bar)
Nitrogen Flow, std L/min Nitrogen Flow, std L/min
Outlet Pressure, psig

Outlet Pressure, psig


Outlet Pressure, bar

Outlet Pressure, bar


Inlet Pressure
2200 psig
(151 bar) 100 psig Inlet Pressure
(6.8 bar) 500 psig 2200 psig
(34.4 bar) (151 bar)

100 psig
(6.8 bar)
500 psig 100 psig
100 psig (34.4 bar) (6.8 bar)
(6.8 bar) 500 psig 2200 psig 500 psig 2200 psig
(34.4 bar) (151 bar) (34.4 bar) (151 bar)

Nitrogen Flow, std ft3/min Nitrogen Flow, std ft3/min

Pressure Control Ranges Pressure Control Ranges


0 to 250 psig 0 to 500 psig 0 to 1000 psig 0 to 1500 psig
(0 to 17.2 bar) (0 to 34.4 bar) (0 to 68.9 bar) (0 to 103 bar)
Nitrogen Flow, std L/min Nitrogen Flow, std L/min

Inlet Pressure Inlet Pressure


Outlet Pressure, psig

Outlet Pressure, psig

2200 psig
Outlet Pressure, bar

Outlet Pressure, bar


2200 psig
(151 bar) (151 bar)
500 psig
(34.4 bar)
1000 psig 1500 psig
(68.9 bar) (103 bar)

500 psig
(34.4 bar)
1000 psig 2200 psig 1000 psig 2200 psig
(68.9 bar) (151 bar) (68.9 bar) (151 bar)

Nitrogen Flow, std ft3/min Nitrogen Flow, std ft3/min

Flow Coefficient 0.20; Maximum Inlet Pressure 3600 psig (248 bar)
Pressure Control Ranges Pressure Control Ranges
0 to 25 psig 0 to 100 psig 0 to 500 psig 0 to 1500 psig
(0 to 1.7 bar) (0 to 6.8 bar) (0 to 34.4 bar) (0 to 103 bar)
Nitrogen Flow, std L/min Nitrogen Flow, std L/min
REGULATORS
K SERIES

Inlet Pressure
2200 psig
Outlet Pressure, psig

Outlet Pressure, psig

Inlet Pressure
Outlet Pressure, bar

Outlet Pressure, bar

2200 psig (151 bar)


(151 bar)
100 psig 500 psig
(6.8 bar) (34.4 bar) 1500 psig
100 psig (103 bar)
(6.8 bar)
500 psig
(34.4 bar)
2200 psig 2200 psig
500 psig (151 bar)
(151 bar) (34.4 bar)

Nitrogen Flow, std ft3/min Nitrogen Flow, std ft3/min


46 Pressure Regulators and Filters

K Series Pressure-Reducing Regulator Flow Data


The graphs illustrate the change or “droop” in outlet pressures as the flow rate increases.

KHP Series
Flow Coefficient 0.06; Maximum Inlet Pressure 10 000 psig (689 bar)
Pressure Control Ranges Pressure Control Range
0 to 500 psig 0 to 750 psig 10 to 1500 psig
(0 to 34.4 bar) (0 to 51.6 bar) (0.68 to 103 bar)
Nitrogen Flow, std L/min Nitrogen Flow, std L/min

Inlet Pressure
Inlet Pressure 8000 psig (551 bar)
Outlet Pressure, psig

Outlet Pressure, psig


Outlet Pressure, bar

Outlet Pressure, bar


8000 psig (551 bar) 5000 psig (344 bar)
5000 psig (344 bar)

1000 psig
(68.9 bar)
1500 psig
8000 psig (103 bar)
(551 bar)
1000 psig 5000 psig
(68.9 bar) (344 bar)

Nitrogen Flow, std ft3/min Nitrogen Flow, std ft3/min

Pressure Control Ranges Pressure Control Ranges


15 to 2500 psig 25 to 3600 psig 50 to 6000 psig 100 to 10 000 psig
(1.0 to 172 bar) (1.7 to 248 bar) (3.4 to 413 bar) (6.8 to 689 bar)
Nitrogen Flow, std L/min Nitrogen Flow, std L/min

Inlet Pressure
8000 psig (551 bar)
Inlet Pressure
Outlet Pressure, psig

Outlet Pressure, psig


Outlet Pressure, bar

Outlet Pressure, bar


9000 psig (620 bar)
3500 psig 5000 psig
(241 bar) (344 bar)

8000 psig
(551 bar) 5000 psig
(344 bar)
8000 psig (551 bar)
3000 psig
(206 bar) 5500 psig (378 bar)

Nitrogen Flow, std ft3/min Nitrogen Flow, std ft3/min


REGULATORS
K SERIES
Pressure Regulators—K Series 47

K Series Pressure-Reducing Regulator Flow Data


The graphs illustrate the change or “droop” in outlet pressures as the flow rate increases.

KHP Series KHR Series


Flow Coefficient 0.25; Flow Coefficient 0.06;
Maximum Inlet Pressure 10 000 psig (689 bar) Maximum Inlet Pressure 10 000 psig (689 bar)
Pressure Control Ranges Pressure Control Ranges
0 to 500 psig 10 to 1500 psig 0 to 500 psig 0 to 750 psig
(0 to 34.4 bar) (0.68 to 103 bar) (0 to 34.4 bar) (0 to 51.6 bar)
Nitrogen Flow, std L/min Water Flow, L/min

Inlet Pressure Inlet Pressure


8000 psig (551 bar) 8000 psig (551 bar)
Outlet Pressure, psig

Outlet Pressure, psig


5000 psig (344 bar)

Outlet Pressure, bar

Outlet Pressure, bar


1500 psig (103 bar) 1000 psig 5000 psig
(68.9 bar) (344 bar)

8000 psig (551 bar)


5000 psig (344 bar) 1000 psig 5000 psig
1000 psig (68.9 bar) (68.9 bar) (344 bar)
8000 psig
(551 bar)

Nitrogen Flow, std ft3/min Water Flow, U.S. gal/min

Pressure Control Range Pressure Control Ranges


25 to 3600 psig 10 to 1500 psig 15 to 2500 psig
(1.7 to 248 bar) (0.68 to 103 bar) (1.0 to 172 bar)
Nitrogen Flow, std L/min Water Flow, L/min
Outlet Pressure, psig

Outlet Pressure, psig


Outlet Pressure, bar

Outlet Pressure, bar


Inlet Pressure 5000 psig 8000 psig
Inlet Pressure 3000 psig (344 bar) (551 bar)
5000 psig (344 bar) (206 bar)

3500 psig
(241 bar)
8000 psig
(551 bar) 1500 psig 5000 psig 8000 psig
(103 bar) (344 bar) (551 bar)

Nitrogen Flow, std ft3/min Water Flow, U.S. gal/min

Pressure Control Range Pressure Control Ranges


100 to 10 000 psig 25 to 3600 psig 50 to 6000 psig 100 to 10 000 psig
(6.8 to 689 bar) (1.7 to 248 bar) (3.4 to 413 bar) (6.8 to 689 bar)
Nitrogen Flow, std L/min Water Flow, L/min
REGULATORS

Inlet Pressure
K SERIES

9000 psig
Outlet Pressure, psig

Outlet Pressure, psig


Outlet Pressure, bar

Outlet Pressure, bar

(620 bar)
Inlet Pressure
9000 psig (620 bar)

5500 psig 8000 psig


(378 bar) (551 bar)

8000 psig
3500 psig 5000 psig (551 bar)
(241 bar) (344 bar)

Nitrogen Flow, std ft3/min Water Flow, U.S. gal/min


48 Pressure Regulators and Filters

K Series Pressure-Reducing Regulator Flow Data


The graphs illustrate the change or “droop” in outlet pressures as the flow rate increases.

KPP Series
Flow Coefficient 0.02; Flow Coefficient 0.06;
Maximum Inlet Pressure 2000 psig (137 bar) Maximum Inlet Pressure 2000 psig (137 bar)
Pressure Control Range Pressure Control Ranges
0 to 1000 psig 0 to 1000 psig 0 to 1500 psig 0 to 2000 psig
(0 to 68.9 bar) (0 to 68.9 bar) (0 to 103 bar) (0 to 137 bar)
Nitrogen Flow, std L/min Nitrogen Flow, std L/min

Inlet Pressure
2000 psig
Outlet Pressure, psig

Outlet Pressure, psig


Outlet Pressure, bar

Outlet Pressure, bar


(137 bar)

Inlet Pressure
1000 psig 2000 psig
(68.9 bar) (137 bar)

1000 psig
(68.9 bar)

Nitrogen Flow, std ft3/min Nitrogen Flow, std ft3/min

Flow Coefficient 0.02; Flow Coefficient 0.06;


Maximum Inlet Pressure 4000 psig (275 bar) Maximum Inlet Pressure 6000 psig (413 bar)
Pressure Control Range Pressure Control Ranges
0 to 2000 psig 0 to 3000 psig 0 to 3600 psig
(0 to 137 bar) (0 to 206 bar) (0 to 248 bar)
Nitrogen Flow, std L/min Nitrogen Flow, std L/min

Inlet Pressure
5000 psig (344 bar)
Outlet Pressure, psig

Outlet Pressure, psig


Outlet Pressure, bar

Outlet Pressure, bar


Inlet Pressure 3500 psig
3000 psig (241 bar)
(206 bar)

5000 psig
(344 bar)
2000 psig
(137 bar) 3000 psig
(206 bar)

Nitrogen Flow, std ft3/min Nitrogen Flow, std ft3/min


REGULATORS
K SERIES
Pressure Regulators—K Series 49

K Series Back-Pressure Regulator Flow Data


The graphs illustrate the change in inlet pressure as the flow rate increases.

KBP Series KFB Series


Flow Coefficient 0.20 Flow Coefficient 1.0
Nitrogen Flow, std L/min Nitrogen Flow, std L/min

Pressure Control Range


0 to 500 psig (0 to 34.4 bar)
Pressure Control Range
Inlet Pressure, psig

Inlet Pressure, psig


Inlet Pressure, bar

Inlet Pressure, bar


0 to 100 psig (0 to 6.8 bar)

0 to 250 psig
(0 to 17.2 bar)

0 to 100 psig (0 to 6.8 bar) 0 to 50 psig


(0 to 3.4 bar)

Nitrogen Flow, std ft3/min Nitrogen Flow, std ft3/min

KCB Series
Flow Coefficient 0.20
Nitrogen Flow, std L/min
Inlet Pressure, psig

Inlet Pressure, bar

Pressure Control Range


0 to 375 psig (0 to 25.8 bar)

0 to 250 psig
(0 to 17.2 bar)

0 to 100 psig (0 to 6.8 bar)

0 to 50 psig (0 to 3.4 bar)

Nitrogen Flow, std ft3/min

REGULATORS
K SERIES
50 Pressure Regulators and Filters

K Series Back-Pressure Regulator Flow Data


The graphs illustrate the change in inlet pressure as the flow rate increases.

KPB Series
Flow Coefficient 0.06 Flow Coefficient 0.20
Nitrogen Flow, std L/min Nitrogen Flow, std L/min

Pressure Control Range


Pressure Control Range 0 to 3000 psig
Inlet Pressure, psig

Inlet Pressure, psig


0 to 2000 psig

Inlet Pressure, bar

Inlet Pressure, bar


(0 to 206 bar)
(0 to 137 bar)

0 to 1000 psig
0 to 1000 psig (0 to 68.9 bar)
(0 to 68.9 bar)

Nitrogen Flow, std ft3/min Nitrogen Flow, std ft3/min

Nitrogen Flow, std L/min

Pressure Control Range


Inlet Pressure, psig

Inlet Pressure, bar

0 to 3000 psig
(0 to 206 bar)

Nitrogen Flow, std ft3/min

Nitrogen Flow, std L/min

Pressure Control Range


0 to 4000 psig (0 to 275 bar)
Inlet Pressure, psig

Inlet Pressure, bar


REGULATORS
K SERIES

Nitrogen Flow, std ft3/min


Pressure Regulators—K Series 51

K Series Back-Pressure Regulator Flow Data


The graphs illustrate the change in inlet pressure as the flow rate increases.

KHB Series
Flow Coefficient 0.06 Flow Coefficient 0.25
Nitrogen Flow, std L/min Nitrogen Flow, std L/min

Pressure Control Range


Inlet Pressure, psig

Inlet Pressure, psig


Inlet Pressure, bar

Inlet Pressure, bar


25 to 3600 psig
Pressure Control Range (1.7 to 248 bar)
10 to 1500 psig
(0.68 to 103 bar)
10 to 1500 psig
0 to 750 psig (0.68 to 103 bar)
(0 to 51.6 bar)

0 to 500 psig 0 to 500 psig


(0 to 34.4 bar) (0 to 34.4 bar)

Nitrogen Flow, std ft3/min Nitrogen Flow, std ft3/min

Nitrogen Flow, std L/min Nitrogen Flow, std L/min


Inlet Pressure, psig

Inlet Pressure, psig


Inlet Pressure, bar

Inlet Pressure, bar


Pressure Control Range Pressure Control Range
25 to 3600 psig 100 to 10 000 psig
(1.7 to 248 bar) (6.8 to 689 bar)

15 to 2500 psig
(1.0 to 172 bar)

Nitrogen Flow, std ft3/min Nitrogen Flow, std ft3/min

Nitrogen Flow, std L/min


Inlet Pressure, psig

Inlet Pressure, bar

Pressure Control Range


100 to 10 000 psig
(6.8 to 689 bar)

REGULATORS
K SERIES
Nitrogen Flow, std ft3/min
52 Pressure
Gi Regulators and Filters R

Port Configurations
Port G
configurations
o Gi are available
Go as shown in the regulator ordering information
Pressure Reducing — right-to-left Pressure Reducing — r
pages. The symbols indicate the port location of factory-assembled accessories.
For alternative accessory locations, contact your authorized Swagelok
R
representative.
Go/R
Select regulators are available
Port Configuration Symbols on special order with additional
Filtered Accessory Gi Inlet gauge R Relief valve port configurations. Contact your
Inlet Go/R
Go Outlet gauge
Pressure
Pressure
Pressure
Go/R Outlet gauge or relief
Reducing
Reducing
Reducing — right-to-left
— right-to-left
— right-to-left
authorized Swagelok representative
Filtered main inlet valve for more information.
Outlet

Factory-assembled cylinder connections are placed on a filtered main inlet


Go/R Go/R Go/R GoGoG/R
i Go Gi
Go/R
port; isolation valves are placed on an outlet port 180° from the cylinder
connection.

Go/R Go/R GoG/R


i Gi R
Pressure-Reducing
Pressure Reducing — right-to-left Regulators
Pressure Reducing — right-to-left
Right-to-Left Flow Pressure
Pressure
Reducing
Pressure
Reducing
— left-to-right
Reducing
— left-to-right
— left-to-right

GoG/R
o/R Go/R i Go
Go/R Go Gi GoGoG/R GoGiGi Go Gi Go Gi Go Gi Go Go Gi

Configuration Go/R Go/R Go/R

Go/R Gi GoG/R
i Gi R R RR

Designator A C E F HGo/R Go/R GLo/R K


Pressure Reducing
Pressure — left-to-right
Reducing — left-to-right
Left-to-Right
G G
Flow GoGoGi GG GoGiGi Go Gi
Go/R o i Go/R i o GG
o
o GiG
o Go

GoG/R GoG
/Ri Gi Gi Go Gi Go Gi Go Gi Go Gi Go Gi Go
i
Back Pressure — right-to-left
Back Pressure — right-to-left
Gi Configuration Gi R R RR R

Go/R Go/R Go/R Go/R Go/R R R R


Gi Gi Gi Gi
Designator A B E M N
Go Gi Go Go Gi Go

G G Gi G o G i G o Gi Go Gi Go
Back-Pressure
Back Pressure Regulators
—i right-to-left
Back
Back Pressure —i right-to-left
Pressure R
— right-to-left R R MPC Port Configurations
R R
Right-to-Left Flow Pressure Reducing
Go/R Go/R Go Go Go R R
Gi Gi Gi Gi Gi Gi
Inlet Outlet Outlet Outlet

Configuration Configuration Inlet

R Pressure
Back Pressure
Back R left-to-right
— — left-to-right 2-Port 3-Port
Designator A D V Designator 5 6
REGULATORS

Go Go
K SERIES

Left-to-Right Flow Back Pressure

Gi Gi
Outlet Inlet Inlet Inlet
Configuration Configuration Outlet
Back
Back Pressure Pressure — left-to-right
— left-to-right
Back Pressure — left-to-right
Gi Gi
2-Port 3-Port
Designator A G Designator 7 8

Gi Gi Gi

Gi Gi Gi
Pressure Regulators—K Series 53

Options and Accessories


Regulator accessories are available
separately or mounted on Swagelok
regulators. Some accessories limit
regulator pressure or temperature
ratings. Additional materials, options,
and accessories are available.
Contact your authorized Swagelok
representative for more information.

Cylinder Connections
■ Available in a variety of 4 in (100 mm) long CGA, BS or DIN
connections
■ Stainless steel construction
Insert a designator into the ordering number as shown in the
appropriate regulator ordering information pages.

Cylinder Gases and Connections


Rated Regulator inlet pressures and any
Cylinder Typical Gases Pressure Connection optional accessories must be rated
Connection (others may be applicable) psig (bar) Designator to the Cylinder connectors pressure.
CGA 320 Carbon Dioxide 3000 (206) B See the ordering information for each
CGA 347 High pressure Air 5500 (379) 1 regulator for details.
CGA 350 Hydrogen, Natural Gas 3000 (206) D
CGA 540 Oxygen 3000 (206) F➀
CGA 580 Helium, Nitrogen 3000 (206) G
CGA 590 Sulfur Hexafluoride 3000 (206) H
CGA 660 Nitrogen Dioxide, Phosgene 3000 (206) J
CGA 680 High pressure inert gas 5500 (379) 2
CGA 695 High pressure flammable gas 5500 (379) 3
BS 3 Argon, Helium 3600 (250) R
BS 4 Hydrogen, Natural Gas 3600 (250) S
BS 8 Carbon Dioxide 3600 (250) V
BS/ISO 30 High pressure inert gas 4351 (300) 4
BS/ISO 31 High pressure Air 4351 (300) 5
BS/ISO 32 High pressure oxidising gas 4351 (300) 6
BS/ISO 38 High pressure flammable gas 4351 (300) 8
DIN 1 Ethane, Hydrogen 4351 (300) K
Carbon monoxide,
DIN 5 4351 (300) L
Hydrogen sulfide
DIN 6 Ammonia, Xenon 4351 (300) M
DIN 8 Chlorine, Hydrogen chloride 4351 (300) N
DIN 10 Nitrogen 4351 (300) P
REGULATORS
K SERIES

DIN 13 Air 4351 (300) Z


➀ Available only on select KPR and KCY series regulators. Contact your
authorized Swagelok representative.

Other cylinder connections are also available. Contact your


authorized Swagelok representative for more information.
54 Pressure Regulators and Filters

Options and Accessories


Isolation Valves
■ Allow isolation from
downstream equipment
■ Working pressures up to
5000 psig (344 bar)
■ 316 stainless steel construction
■ Swagelok integral-bonnet
needle valve (1 series)
■ Used in conjunction with an
adjustable regulator relief valve
See the Swagelok Integral-Bonnet Needle Valves catalog
(MS-01-164) for more information.

Pressure Gauges Isolation Valve and Relief Valve Ordering


■ Provides measure of inlet Information
pressure, outlet pressure, or both Isolation valves are available factory assembled on KCP,
■ 2 1/2 in. (63 mm) dial size with KPP, KPF, KHP, KHR, and KHB series regulators. Isolation
1/4 in. male NPT connection and adjustable regulator relief valves are available factory
assembled on KPR, KCY, KCM, KLF, and KHF series regulators.
■ 1 1/2 in. (40 mm) dial size with
1/8 in. male NPT connection To order a regulator factory assembled with an isolation valve
or isolation valve and adjustable regulator relief valve, insert a
■ Stainless steel cases and
designator from the table below into the ordering number as
wetted components shown in the appropriate regulator ordering information pages.
See the Swagelok Pressure Gauges, Industrial and
Process catalog (MS-02-170) for more information. Valve Designator
Isolation
Cleaning Relief Isolation and
Gauges assembled to ASTM G93 Level E or SC-11–cleaned Description Only Only➀ Relief
regulators are cleaned in accordance with ASME B40.100 Kenmac® KVV series adjustable
1 — —
level IV. regulator relief valve
1/4 in. male NPT inlet
1/4 in. Swagelok tube fitting outlet A 2
angle pattern isolation valve
Ordering Information
1/4 in. male NPT inlet
To order a regulator assembled with gauges, insert a 6 mm Swagelok tube fitting outlet B 3
designator from the table below into the ordering number angle pattern isolation valve
as shown in the appropriate regulator ordering information 1/4 in. male NPT inlet
pages. The maximum gauge pressures are appropriate for 1/4 in. female NPT outlet C 4
the maximum inlet pressure and/or control pressure ordered. angle pattern isolation valve

1/4 in. Swagelok tube fitting
inlet➁ and outlet E 6
Gauge Scale Gauge Designator
straight pattern isolation valve
primary unit Inlet and Inlet Outlet Gauge
6 mm Swagelok tube fitting
(secondary unit) Outlet Only Only Model➀
inlet➁ and outlet F 7
psig (bar) straight pattern isolation valve
1 A G C
(North America only)➁
3/8 in. Swagelok tube fitting inlet➁
psig (bar) 3 C J B 1/4 in. female NPT outlet G 8
psig (kPa) 5 E L C straight pattern isolation valve
REGULATORS

bar (psig) 2 B H B ➀ Not available on KPR, KCY, KCM, KLF, and KHF series regulators, because a
K SERIES

relief valve is needed to protect the diaphragm sensing mechanism.


MPa 4 D K B ➁ Includes male NPT to Swagelok tube adapter fitting (required for regulators
➀ KCP and KCB series regulators are assembled with M model gauges. with 1/8 and 1/2 in. female NPT ports).
➁ Not available for KCP and KCB series regulators.
Pressure Regulators—K Series 55

Options and Accessories


Kenmac Adjustable
Regulator Relief Valves
(KVV Series)
■ Provide nonsafety-related
pressure protection for
Swagelok regulators

Technical Data Flow Data


Relief Pressure Ranges The graph illustrates the discharge characteristics of the
Kenmac adjustable regulator relief valve.
■ Based on the regulator control range
Air Flow, std L/min
Regulator Relief
Control Range Pressure Range
psig (bar) psig (bar) Relief Pressure Range
150 to 500 psig
Inlet Pressure, psig

0 to 10 (0 to 0.68)

Inlet Pressure, bar


(10.3 to 34.4 bar)
0 to 25 (0 to 1.7) 0 to 100 (0 to 6.8)
0 to 50 (0 to 3.4)
0 to 100 (0 to 6.8) 50 to 200 (3.4 to 13.7)
0 to 250 (0 to 17.2) 50 to 200 psig
150 to 500 (10.3 to 34.4) (3.4 to 13.7 bar)
0 to 500 (0 to 34.4)
0 to 100 psig
Maximum Operating Temperature (0 to 6.8 bar)

■ 392°F (200°C)
Weight Air Flow, std ft3/min
■ 0.26 lb (0.12 kg)
Ports
■ 1/4 in. NPT male inlet and female outlet

Materials of Construction Ordering Information


• For valves not actuated for
To order a KVV adjustable regulator a period of time, initial relief
Component Material
relief valve separately, select an pressure may be higher than the
Body, poppet,
spring button, 316 SS
ordering number from the table below. set pressure.
adjusting screw
Seal Fluorocarbon FKM Relief Pressure Range Ordering • Some system applications
psig (bar) Number require relief valves to meet
Range spring 302 SS specific safety codes. The
0 to 100 (0 to 6.8) KVV11DE1
Wetted components listed in italics. system designer and user must
50 to 200 (3.4 to 13.7) KVV11DG1
determine when such codes
150 to 500 (10.3 to 34.4) KVV11DI1
Testing apply and whether these relief
valves conform to them.
Every KVV series regulator relief
valve is factory tested at its maximum • Kenmac adjustable regulator
rated pressure, then set to zero when relief valves should never REGULATORS

assembled to the regulator. be used as ASME Boiler and


K SERIES

Pressure Vessel Code safety


• Reset relief pressure to relief devices.
the desired value before
pressurizing the system. • Kenmac adjustable regulator
relief valves are not “Safety
Accessories” as defined in the
Pressure Equipment Directive
2014/68/EU.
56 Pressure Regulators and Filters

Options and Accessories


Hoses
Hoses are available assembled to the inlet of the regulator to
allow connection to remote gas cylinders.
Hose options include:
■ 3 ft long Swagelok 1/4 in. high-pressure, metal flexible hose
(FX series), 1/4 in. female NPT inlet, 1/4 in. male NPT outlet
connected to regulator: SS-FX4PM4PF4-36
Rated to 6000 psig (413 bar) at 100°F (37°C)
■ 3 ft long Swagelok 1/4 in. PTFE-lined, stainless steel braided
hose (TH series), 1/4 in. female NPT inlet, 1/4 in. male NPT
outlet connected to regulator: SS‑TH4PM4PF4-36
Rated to 3100 psig (213 bar) at 100°F (37°C)
See the Swagelok Hose and Flexible Tubing catalog
(MS‑01‑180) for more information.

Cleaning
Hoses are not available assembled to ASTM G93 Level E or
SC‑11 specially-cleaned regulators.

Handles Wall Mounting Brackets


Knob, thumbwheel, and antitamper handles are available. Stainless steel wall mounting brackets are available for many
The green plastic knob handle Swagelok regulators.
is standard for most Swagelok
regulators. Other colors are available;
add a handle color designator to a
regulator ordering number. Knob
Antitamper
Color Designator
Black BK
Thumbwheel
Blue BL
Orange OG
Red RD KCY Series KPR, KLF, KHF, KCP, KPP,
Mounting Bracket KPF, KHP, KBP, KFB, KCB,
Yellow YW KPB, and KHB Series
Requires 1st stage panel-
Mounting Bracket
Example: KPR1FRF412A20000BK mount option. See page 9.

The metal thumbwheel handle is available for the compact


KCB and KCP series regulators. Wall Mounting Bracket Kits
The metal antitamper nut is available to prevent inadvertent
pressure adjustment. Regulator Series Ordering Number
KPR, KLF, KHF, KCP,
KPP, KPF, KHP, KBP, 9R0079
KFB, KCB, KPB, KHB
KCY 9R0149

Maintenance Kits
REGULATORS
K SERIES

Filter Replacement Kits


Filter replacement kits are available for KPR, KCM, KCP, KCY,
Regulator Series Inlet Size Ordering Number
KPP, KHP, KLF, KHR, KHF, and KPF series regulators.
KCP 1/8 in. NPT REG-FILTER-2-KIT5
Filter replacement kits include:
KPR, KCM, KCY, KPP,
1/4 in. NPT REG-FILTER-4-KIT5
■ five sets of filters and carrier assemblies KHP, KLF, KHR
■ instructions. KHF, KPF 1/2 in. NPT REG-FILTER-8-KIT5
Pressure Regulators—K Series 57

Maintenance Kits
KPR, KCP, AND KBP Series Maintenance Kits
Maintenance kits include: Maintenance Kits for Other Maintenance Instructions
■ all wetted components, except for Regulator Series Maintenance instructions for all
the regulator body and piston, if Maintenance kits for KLF, KHF, KPP, Swagelok regulators are available from
applicable KPF, KHP, KHR, KFB, KCB, KCY, KPB, your Swagelok website.
■ wetted lubricant with MSDS KHB, KSV, and KEV series regulators
are available. Maintenance Tools
■ instructions.
To order, contact your authorized Specially designed tools and tool kits
Swagelok representative; to ensure are available to assist in the service
correct kit contents, please provide the and repair of Swagelok regulators.
original regulator ordering number. Contact your authorized Swagelok
representative for more information.

Ordering Information
Build a maintenance kit ordering number by combining the designators in the sequence shown below.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
K P R 1 D 0 0 4 1 2 A 0 - K I T
1 2 3 Regulator Series 6 Maximum Inlet Pressure 10 Flow Coefficient (Cv)
KPR = KPR 0 = Not applicable 1 = 0.02
KCP = KCP 2 = 0.06
KBP = KBP 7 Port Configuration 5 = 0.20➀➁
0 = Not applicable 7 = 0.50➀
4 Body Material, Cleaning ➀ Not available for KCP series with MPC platform
port configuration.
1 = 316 SS and brass 8 Ports (Filter Size) ➁ Required for KBP series.
C = 316 SS and brass, SC‑11 cleaned KPR Series
4 = 1/4 in. female NPT 11 Sensing Mechanism, Vent
5 Pressure Control Range 0 = All other end connections
KPR Series
KPR and KBP Series KBP Series A =Alloy X-750 diaphragm, no-vent
D =0 to 10 psig (0 to 0.68 bar) and 0 = Not applicable models and captured-vent models
0 to 25 psig (0 to 1.7 bar)
KCP Series C =Alloy X-750 diaphragm, self-vent
F =0 to 50 psig (0 to 3.4 bar) and
0 to 100 psig (0 to 6.8 bar) 2 = 1/8 in. female NPT models and self- and captured-
J =0 to 250 psig (0 to 17.2 bar) and M = MPC platform vent models
0 to 500 psig (0 to 34.4 bar) KBP Series
KCP Series 9 Seat, Seal Material A =Alloy X-750 diaphragm, all models
G =0 to 10 psig (0 to 0.68 bar), KPR Series KCP Series
0 to 25 psig (0 to 1.7 bar), 1 = PCTFE P = 316 SS piston
0 to 50 psig (0 to 3.4 bar), 2 = PEEK
REGULATORS
K SERIES
0 to 100 psig (0 to 6.8 bar), and 12 Handle, Mounting
KBP and KCP Series
0 to 250 psig (0 to 17.2 bar)
A = Fluorocarbon FKM, PCTFE 0 = Not applicable
M =0 to 500 psig (0 to 34.4 bar),
0 to 1000 psig (0 to 68.9 bar), and B = Kalrez, PCTFE
0 to 1500 psig (0 to 103 bar)➀ C = Fluorocarbon FKM, PEEK
D = Kalrez, PEEK
➀ Not available with MPC platform port
configuration.
58 Pressure Regulators and Filters

Additional Products
Filters
Swagelok offers a variety of filters, filter elements,
and sizes.
■ 316 SS and brass materials
■ Sintered and strainer elements
■ Tee type, inline, and all-welded models
For more information about Swagelok filters,
see the Filters—FW, F, and TF Series catalog
(MS‑01‑92).

Transducers
Swagelok industrial pressure transducers
electronically monitor fluid system pressure
in a variety of analytical and process
applications.
■ Accurate and repeatable readings
■ Swagelok tube adapter end connections
available for ease of installation and
maintenance
■ CE compliant
For more information about Swagelok
industrial pressure transducers, see the
Industrial Pressure Transducers catalog,
(MS‑02‑225).

• Swagelok pressure regulators are not “Safety


Accessories” as defined in the Pressure Equipment
Directive 2014/68/EU.
• Do not use the regulator as a shutoff device.
REGULATORS
K SERIES

Caution: Do not mix or interchange parts with those of


other manufacturers.
MS-02-230, RevM, December 2017
About this document
Thank you for downloading this electronic catalog, which is part of General Product
catalog Swagelok published in print. This type of electronic catalog is updated as new
information arises or revisions, which may be more current than the printed version.
Swagelok Company is a major developer and provider of fluid system solutions,
including products, integration solutions and services for industry research,
instrumentation, pharmaceutical, oil and gas, power, petrochemical, alternative fuels,
and semiconductor. Our manufacturing facilities, research, service and distribution
facilities support a global network of more than 200 authorized sales and service
centers in 57 countries.
Visit www.swagelok.com to locate your Swagelok representative and obtain any
information on features, technical information and product references, or to learn about
the variety of services available only through authorized sales centers and service
Swagelok.

Safe Product Selection


Warranty Information
When selecting a product, the total system design must be Swagelok products are backed by The Swagelok Limited
considered to ensure safe, trouble-free performance. Function, Lifetime Warranty. For a copy, visit your Swagelok Web site or
material compatibility, adequate ratings, proper installation, contact your authorized Swagelok representative.
operation, and maintenance are the responsibilities of the system
designer and user.

Swagelok, Ferrule-Pak, Goop, Hinging-Colleting, IGC, Kenmac,


Micro-Fit, Nupro, Snoop, Sno-Trik, SWAK, VCO, VCR, Ultra-
Torr, Whitey—TM Swagelok Company
Aflas—TM Asahi Glass Co. Ltd.
AL-6XN—TM Allegheny Ludlum Corporation
AutoCAD—TM Autodesk, Inc.
CSA—TM Canadian Standards Association
DeviceNet—TM ODVA
Kalrez, Krytox—TM DuPont
Elgiloy—TM Elgiloy Specialty Metals
FM —TM FM Global
Grafoil—TM GrafTech International Holdings, Inc.
MAC—TM MAC Valves Inc.
Microsoft, Windows—TM Microsoft Corp.
NACE—TM NACE International
Nitronic—TM AK Steel Corporation
picofast—TM HansTurck KG
Pillar—TM Nippon Pillar Packing Company, Ltd.
Rapid Tap—TM Relton Corporation
15-7 PH, 17-7 PH—TM AK Steel Corp.
Sandvik—TM SandvikAB
Silconert—TM Silcotek Corporation
Simriz—TM Freudenberg-NOK
SolidWorks—TM SolidWorks Corporation
© 2017 Swagelok Company

You might also like