You are on page 1of 278

03 2016

International Markets

Product Catalogue
Beretta is established in Beretta, as first manufacturer The search for efficient The acquisition of
Lecco, a small industrial town in Italy, starts to produce synergies in a long term Beretta by Riello Group
in Northern Italy, faced on the wall-hung gas boilers for vision, whilst aiming at is accomplished. The
Lake Como. The Company residential heating. During the technical excellence, leads advantages of belonging to
starts its business as a sole peak of the oil crisis, Beretta to the creation of “Beretta a large industrial group are
engineering contractor on senses the importance of Progetto Gas”, a joint- great for Beretta, both in
behalf of large industrial natural gas as the ideal venture of Italian companies terms of synergies and brand
groups. energy source for individual operating in the field of home perception worldwide.
home heating. comfort gas appliances.

Beretta begins the production Beretta launches the first Beretta develops Idra Meteo,
of its own brand of kerosene room-sealed wall-hung gas the first wall-hung gas boiler in
and gas oil boilers for boiler, the successful Paros the world specifically designed
individual home heating. The 21M. for outdoor use, creating a
reason for this choice is the Production is entirely focalized new segment in the boiler
innovative idea that a greater on wall-hung gas boilers. market. This product will be
autonomy in heating can lead one of the most successful of
to increased comfort and Beretta history, continuously
savings for the end-user. improved and still available in
the product portfolio as Meteo
and Meteo GREEN.
Beretta logo is restyled Enlargement of Beretta offer Launch of the new floor- Beretta launches MySMART,
to convey the idea of in the renewable energies by standing condensing boiler a condensing wall-hung
Beretta renewed mission the introduction of the heat range Tower Green in boiler, standard equipped
as specialists in home pump Hydronic Unit. three versions (solar, hybrid with BeSMART, the smart
comfort systems. The green and compact) to meet all WiFi thermostat for the
colour of the graphical residential needs. management of home
element emphasizes Beretta comfort via Smartphone and
commitment, since its origins, Tablet (A+ Class System).
to environmental protection.

Beretta enlarges the product Launch on the Italian market Launch of Hybrid Box,
portfolio by introducing solar of Solar Box, a hybrid a hybrid system able to
thermal systems and high system (solar thermal and manage three energy
power condensing boilers in condensing boiler) for outdoor sources (sun, electricity
cascade applications for light- installation in a box, perfectly and gas), while ensuring Beretta is ERP compliant.
commercial and commercial in line with Beretta product maximum efficiency and A concrete commitment to
applications. philosophy: reliability and ease least consumptions. an increasingly
of installation, in a solution of eco sustainable future.
great success.
BE R E T TA

Specialists in residential heating for over forty years.


TODAY Excellence and innovation, since always, for the
comfort within millions of homes all over the world.
Today Beretta confirms its growing trend in the
residential heating and faces new challenges with the
Beretta, after over same enthusiasm and the same commitment of the
beginnings. Because the excellence in the products
forty years since the and in the supplied services remain Beretta’s key
production of its first values.
wall-hung gas boiler, is
nowadays a worldwide
EX C E L L E N C E
known brand in the field
of home heating comfort,
The great expertise gained over the years in the
with Subsidiaries and field of residential heating has made of Beretta a
Distributors on all worldwide known brand, synonymous with quality and
technology. Today, as in the beginnings, the pursuit of
continents. excellence in every activity and, more specifically, the
constant attention to product and services represent
Beretta core values.

RE S I D E N TA L H E AT I N G

Specialists in residential heating systems: this is


Beretta product mission. Nowadays Beretta confirms
its vocation as a leading brand in residential heating
and faces new challenges. To meet the heating
and DHW requirements of medium to large-sized
installations, like schools, hotels, sports centres,
Beretta has developed a complete range of products
for light-commercial and commercial applications,
both for new buildings and as a replacement.
Furthermore, since always sensitive to environmental
issues, Beretta offers new technologies and solutions
that can combine, with maximum efficiency, new
energy sources, always prioritizing renewables.

EF F I C I E N C Y

With a strong focus on residential heating, Beretta


product portfolio concentrates increasingly on
solutions that maximize energy efficiency through the
intelligent integration of several energy sources.
TERRITORY

Beretta customer-centred approach translates into a


worldwide network of specialists: proximity, expertise,
flexibility are Beretta key values. Beretta, after over
forty years since the production of its first wall-hung
gas boiler, is nowadays a worldwide known brand in
the field of home heating solutions, synonymous with
technology and quality. Our products are sold through
Subsidiaries, Sales Partners and OEM Customers in
over 50 countries, on all continents.

compliant

Beretta is ERP compliant.


TECHNOLOGY The new ErP regulations aim to
help the EU countries to reach
Beretta has always shown an exceptional ability to by 2020 the “20-20-20” target,
foresee change and respond to the resulting evolutions meaning a 20% reduction of
in demand. Two examples of many past cases: Beretta gas emissions; a 20% increase
was the first Italian company to produce wall-hung gas in the use of renewable
boilers and - with the Meteo boiler model - the first to energies; a 20% reduction in
produce a wall-hung boiler specifically designed for global energy consumptions.
outdoor installation. A commitment to Progress which
today increasingly takes an environmental slant, with
a view to excellence and cutting-edge technology.
Beretta solutions target improved energy efficiency and
the reduction of emissions, both for the sustainability -20%
of the environment and to ensure all the comfort that
millions of consumers are accustomed to demanding
and receiving from Beretta products. CO2 reduction

+20%

ATTENTION TO ENVIRONMENT
renewable
energies
Beretta commitment is concrete and aims at an increasingly
eco sustainable future.
For years, Beretta has been totally committed to a
system logic which combines the intelligent use of several
sustainable and renewable energy sources, in perfect -20%
harmony with the environment around us, for the home
comfort of millions of consumers who use Beretta products energy
every day. consumptions
BERETTA WORLDWIDE
Beretta Italy ALBANIA
ALGERIA
ARMENIA
AUSTRALIA
Beretta Headquarters with the
AUSTRIA
new Training Centre ATENEO and the
AZERBAIJAN
R&D Laboratory are located in Lecco,
BELARUS
Milan area.
BOSNIA AND HERZEGOVINA
BRAZIL
BULGARIA
CHILE
CHINA
COLOMBIA
Beretta International CROATIA
CYPRUS
CZECH REPUBLIC
Beretta, after over forty years since the DENMARK
production of its first wall-hung gas boiler, FRANCE
is nowadays a worldwide known brand in GEORGIA
the field of home heating comfort, GERMANY
synonymous with technology and quality. GREECE
HUNGARY
Beretta products are sold through IRELAND*
Subsidiaries, Sales Partners and ISRAEL
OEM Customers in over 50 countries ITALY
on all continents. JORDAN
KAZAKHSTAN
Subsidiaries KYRGYZSTAN
CHINA (Beijing) LITHUANIA
POLAND (Torun) MALTA
ROMANIA (Bucarest) MOLDOVA
SPAIN (Barcelona) MOROCCO
NEW ZEALAND
NORWAY
Production sites
PHILIPPINES
ITALY:
POLAND
- Morbegno (Sondrio)
PORTUGAL
- Piombino Dese (Padova)
REPUBLIC OF MACEDONIA
- Volpago (Treviso)
ROMANIA
- Villanova di Cepagatti (Pescara)
RUSSIA
POLAND: SERBIA
- Torun SLOVAKIA
CHINA: SLOVENIA
- Shanghai SPAIN
SWEDEN
TUNISIA
TURKEY
TURKMENISTAN
UKRAINE
UNITED KINGDOM*
UZBEKISTAN

* under Vokèra brand


Wherever you choose a Beretta product
in the world, you will find a local service
team able to ensure all technical support
when needed.
Today, as in the early days, Beretta takes great pride in
the quality of its service. Our commitment to service, CONSOLIDATED
coupled with our policy of continuous innovation and
technological excellence, means that when you choose KNOW-HOW
a Beretta appliance, you are in safe hands.
AT YOUR SERVICE

After-sales service
Beretta puts a great deal of emphasis on
after-sales service, with a central technical
service team committed to supporting
our Subsidiaries and Sales Partners
worldwide to provide locally a qualified
service.

Pre-sales service
The Beretta pre-sales service team,
thanks to the consolidated know-how,
gives advice on the whole portfolio of
products to our Sales Parteners and
Subsidiaries in the world, in order they
can locally support engineers, architects,
specifiers and developers in choosing the
best solution for every project.

Technical training
All Beretta Sales Partners and
Subsidiaries in the world organize locally
technical training courses, focusing on
the need of the installer and engineer to
become familiar with Beretta products
and to enable quick and simple
installation or repair. Our technical training
is structured to ensure you cover: the
appliance range, installation, operation,
wiring, flueing, benchmark, fault finding
and commissioning.

Original spare-parts and accessories


For your complete peace of mind,
the Beretta original spare parts and
accessories are available at any of our
Sales Partners and Subsidiaries all over
the world.
New Advanced Training Centre ATENEO

In recent years, the Heating and Plumbing sector has qualifications and new system solutions, makes a
been facing great changes and new challenges that continuous training process more and more necessary.
have involved all the players operating in this field. For all these reasons, Beretta has deemed it important
European Directives and the new technical standards to further invest in training with the opening of the new
have led to the introduction of new working and Beretta ATENEO Centre in Lecco (Milan area), where
administrative practices. Meanwhile, an increasingly in a new comfortable and technologically advanced
specialised market, with the emergence of new setting, considerably widens its training offer.

ATENEO has been conceived and designed as an Inside the building there are two training rooms, each
advanced Beretta Training Centre and is therefore of them complete with laboratories, dedicated to
fitted with state-of-the-art technologies in order to Residential and Systems applications. The training
facilitate the training process. sessions and activities in ATENEO have a great practical
A computerised system allows interact ive representation and are aimed to convey Beretta’s
presentations with operating products, while competence, as a specialist in heating systems.
simulating specific applications.
Over 400 m2 dedicated to specialized training

A training room with Beretta A training room with Beretta


Residential products, Systems products, with
with training benches and training benches and operating
operating products products for the Plant Room.

Multimedia Equipment allowing


the instantaneous simulation of
practical applications
ErP Directive 2009/125/EC,
AN EPOCH-MAKING TURNING POINT

The ErP abbreviation, which stands for “Energy related Products”, identifies the Directive
2009/125/EC, aiming at reducing the energy consumption of the products through the
eco-design. September 26, 2015, the date on which the ErP Directive came into force,
represents an epoch-making turning point for the appliances producing central
heating and domestic hot water. Since that date also a new energy labelling of the
products has been implemented, recasting the corresponding Directive 2010/30/EU.

The rules foresee that all products for central relevant single appliances.
heating and domestic hot water production, with Since the same date, new requirements of
nominal output lower than or the same as 70 kW, seasonal efficiency have been set for appliances
can be admitted on the market only if displaying for central heating only and for combination
an energy label showing the efficiency class. appliances (central heating and domestic hot
According to the different kinds of appliances/ water production). These requirements concern
technologies, different energy labels are products with nominal output lower than or
foreseen, but all of them are rated through a the same as 400kW and prevent the entry on
graded colour scale identifying at a glance the the market of the least efficient products. Also
different efficiency levels. The labelling aims domestic hot water tanks have to meet new
at giving the consumer the possibility to easily requirements in terms of thermal losses. The
identify the efficiency level of a product and to buffer tanks are rated according to their efficiency
compare homogeneously with each others the in terms of thermal losses too. For the domestic
products that use the same technology. For hot water tanks up to 500 litres, the labelling
those products whose efficiency is influenced is mandatory; the ones from 500 to 2000 litres
by external weather conditions, like for instance are bound to the respect of energy efficiency
the heat pumps, the efficiency level is reported classification. Concerning the heat pumps
for indicative temperature zones. for central heating and the mixed appliances,
Besides the product labels, the European rules besides the seasonal efficiency limits, specific
foresee a system label in case of systems sound levels limits were set according to the
made of different appliances, components and output sizes. Also the gas water heaters, the
relevant controls. wall-hung heat pumps for domestic hot water
This second type of labelling, thanks to the production and the solar thermal cylinders, in
virtuous synergy among the different elements, order to be admitted on the market, besides
gives the possibility to make systems able to the energy labelling have to meet a series of
reach even higher levels of efficiency than the requirements in terms of efficiency.

LABELS EXAMPLES
01. 02.
Energy Label for a condensing wall-hung gas boiler: Energy Label for a heat pump for space heating:

A A
E
B F C

C
B
D D

A Manufacturer’s name and model name A Manufacturer’s name and model name
B Heating energy efficiency class B Sound power levels of indoor and outdoor units
C Nominal output C Heating energy class at high and low temperatures
D Sound power level D Nominal heating capacity at three indicative temperature
E Domestic hot water load profile zones

F Domestic hot water energy class

03. 04.
Energy Label for a water heater: LABELLING OF A HEATING SYSTEM
Thanks to the ErP rules, that foresee the labelling of
heating systems, comparisons are now possible also
among systems, made of different products:

A A D
B
B E
D

C
C E

A Manufacturer’s name and model name A Dealer’s and/or Supplier’s name


B Domestic hot water load profile B Energy efficiency class of appliance for space heating
C Sound power level C System components
D Domestic hot water energy efficiency class D Dealer’s and/or Supplier’s model identifier
E Yearly energy and/or fuel consumption E System Energy efficiency class (to be calculated by the
Dealer and/or Supplier)

The energy efficiency classes, divided in two macro-groups In the following years, the labels of products and systems will
of central heating and domestic hot water preparation, are be remodeled by removing the least efficient energy classes.
the same for all relevant types of appliances, allowing the
end-user to make very realistic comparisons among different
products.
INDEX
SMART SYSTEMS
page 23

CONDENSING BOILERS
page 39

STANDARD-EFFICIENCY BOILERS
page 73

WATER HEATERS
page 93

FLUES AND ACCESSORIES


page 97

COMPLEMENTARY ITEMS
page 127

MODULAR CONDENSING BOILERS


page 145

HEAT PUMPS
page 187

SOLAR THERMAL
page 199

SYSTEM DIAGRAMS
page 277
SMART SYSTEMS
Systems for the home comfort management via smartphone and tablet
NEW SYSTEM BeSMART (WiFi programmable room-thermostat) _______________________________________ 24
NEW SYSTEM MySMART (combi wall-hung condensing boilers) _______________________________________ 37

CONDENSING BOILERS
Product matrix of condensing wall-hung boilers _____________________________________ 40
Combi and ‘heating-only’ wall-hung boilers
EXCLUSIVE GREEN E __________________________________________________________ 42
MYNUTE GREEN _____________________________________________________________ 46
MYNUTE GREEN _____________________________________________________________ 47
CIAO GREEN ________________________________________________________________ 50
CIAO GREEN ________________________________________________________________ 50
QUADRA GREEN _____________________________________________________________ 52
QUADRA GREEN _____________________________________________________________ 52

Combi wall-hung boilers for high temperature systems


MYNUTE SINTHESI ____________________________________________________________ 54
NEW CIAO AT ___________________________________________________________________ 56

Combi wall-hung boilers with built-in DHW tank


EXCLUSIVE BOILER GREEN HE ____________________________________________________ 44
MYNUTE BOILER GREEN ________________________________________________________ 48
MYNUTE BOILER GREEN ________________________________________________________ 48

High power wall-hung boilers


MYNUTE GREEN 50 R.S.I. _______________________________________________________ 58
MYNUTE GREEN 50 R.S.I. _______________________________________________________ 58

HYBRID combi floor-standing boilers with built-in DHW cylinder, for solar thermal
SYSTEM TOWER GREEN HE HYBRID S ____________________________________________________ 62

HYBRID combi floor-standing boilers with built-in DHW cylinder


SYSTEM TOWER GREEN HE HYBRID ______________________________________________________ 65

Combi floor-standing boilers with built-in DHW cylinder, for solar thermal
XL

SYSTEM TOWER GREEN HE S __________________________________________________________ 68

Combi floor-standing boilers with built-in DHW tank


TOWER GREEN HE ____________________________________________________________ 69
TOWER GREEN HE COMPACT _____________________________________________________ 70

‘Heating-only’ floor-standing boilers


TOWER GREEN HE COMPACT R.S.I._________________________________________________ 71

16
STANDARD-EFFICIENCY BOILERS
Product matrix of standard-efficiency wall-hung boilers ______________________________ 74
Combi and ‘heating-only’ wall-hung boilers
EXCLUSIVE _________________________________________________________________ 76
EXCLUSIVE _________________________________________________________________ 76
MYNUTE S _________________________________________________________________ 78
MYNUTE S _________________________________________________________________ 78
CIAO S ____________________________________________________________________ 80
Combi wall-hung boilers
QUADRA II _________________________________________________________________ 82
QUADRA II _________________________________________________________________ 82
CIAO _____________________________________________________________________ 84
CIAO _____________________________________________________________________ 84

Combi wall-hung boilers with built-in DHW tank


MYNUTE BOILER _____________________________________________________________ 86
MYNUTE BOILER _____________________________________________________________ 86

‘Heating-only’ cast-iron floor-standing boilers


NOVELLA R.A.I. ____________________________________________________________________ 88
NOVELLA R.A.P. ____________________________________________________________________ 89
NOVELLA MAXIMA __________________________________________________________________ 90

WATER HEATERS
Instantaneous water-heaters
NEW IDRABAGNO ESI _____________________________________________________________ 94
FONTE AP __________________________________________________________________ 95
FONTE AE __________________________________________________________________ 95

FLUES AND ACCESSORIES


Flue lengths
Maximum flue lengths table ___________________________________________________________ 98

Condensing flue options


Ø 80 twin flue system in plastic (PP) for condensing boilers ____________________________________ 100
Ø 80 twin flue system in aluminium for condensing boilers _____________________________________ 102
Ø 60/100 concentric flue system in plastic (PP/PPu) for condensing boilers _________________________ 104
Ø 60/100 concentric flue system in PP/Met for condensing boilers _______________________________ 106
Ø 80/125 concentric flue system in PP/Met for condensing boilers _______________________________ 108
Ø 60 flue range in plastic (PP) for inside-chimney installation, specific for condensing boilers _____________ 110
Ø 80 flue range in plastic (PP) for inside-chimney installation, specific for condensing boilers _____________ 112
Ø 50 flue range in PPs (H1 Class) for inside-chimney installation, specific for condensing boilers __________ 115

Standard-efficiency flue options


Ø 80 twin flue system in aluminium for standard-efficiency boilers _______________________________ 116
Ø 60/100 concentric flue system in Al/Met for standard-efficiency boilers __________________________ 118
Ø 60/100 concentric flue system in Al/PPu for standard-efficiency boilers ___________________________ 120
Ø 80/125 concentric flue system in Al/Met for standard-efficiency boilers __________________________ 122

17
Accessories for boilers
Comfort accessories ________________________________________________________________ 124
Hydraulic accessories _______________________________________________________________ 125
Special accessories _________________________________________________________________ 126

COMPLEMENTARY ITEMS
Hydraulic separators
CONNECT LE - with vertical separator and direct zones _______________________________________ 128
CONNECT LE - with vertical separator and motorized mixed zones _______________________________ 130
CONNECT BASE LE - with vertical separator and thermostatic mixed zones _________________________ 132
CONNECT AT/BT LE - with horizontal separator _____________________________________________ 134

DHW tanks for wall-hung boilers


F IDRA BV ___________________________________________________________________ 135
BV 120 ___________________________________________________________________ 136
IDRA M 60 _________________________________________________________________ 137

Hydraulic devices
SOLAR DIVERTER VALVE _____________________________________________________________ 138

Devices for the systems management


CONTROL SYSTEM V3 ______________________________________________________________ 140
CONTROL SYSTEM V4 ______________________________________________________________ 141

Programmable digital room thermostat


ALPHA 7D/ALPHA 7D WIRELESS _______________________________________________________ 142

Digital room thermostat


ALPHA DGT/ALPHA DGT WIRELESS _____________________________________________________ 143

MODULAR CONDENSING BOILERS


Modular wall-hung boilers for light commercial applications up to 200 kW
MYNUTE GREEN 50 R.S.I. ______________________________________________________ 146
MYNUTE GREEN 50 R.S.I. ______________________________________________________ 146
MYNUTE GREEN 50 R.S.I. - LINEAR FREE-STANDING CASCADE APPLICATIONS _______________________ 148
MYNUTE GREEN 50 R.S.I. - BACK-TO-BACK CASCADE APPLICATIONS _____________________________ 150

Modular wall-hung boilers for commercial applications


POWER PLUS ______________________________________________________________ 153
POWER PLUS - LINEAR WALL-HUNG OR FREE-STANDING APPLICATIONS ___________________________ 155
POWER PLUS - BACK-TO-BACK FREE-STANDING APPLICATIONS ________________________________ 160
Specific accessories for Power Plus _____________________________________________________ 164
Specific components for Power Plus _____________________________________________________ 165
Flues for Power Plus ________________________________________________________________ 166

Modular floor-standing boilers for commercial applications


POWER PLUS BOX - 500 SERIES _______________________________________________________ 170
POWER PLUS BOX - 1000 SERIES ______________________________________________________ 174
Specific accessories for Power Plus BOX _________________________________________________ 180

Plate heat exchanger


SP - INSPECTABLE PLATE HEAT EXCHANGERS _____________________________________________ 184

18
HEAT PUMPS
Heat pumps
ACQUAZENIT - DHW WALL-HUNG HEAT PUMPS ______________________________________ 188
HP 260 ACS - DHW FLOOR-STANDING HEAT PUMPS ___________________________________ 190
HYDRONIC UNIT LE - HYDRONIC REVERSIBLE HEAT PUMPS ______________________________ 192

Buffer tanks
STOR H - INERTIAL COLD/HOT WATER BUFFER TANK __________________________________ 196

SOLAR THERMAL
Forced circulation systems
FKB-SOL - SYSTEMS WITH FLAT COLLECTORS SCF-25B AND IDRA FI-LE CYLINDER ___________________ 200
F2B-SOL - SYSTEMS WITH FLAT COLLECTORS SCF-20B AND IDRA CYLINDER _______________________ 204

Product matrix of solar collectors _________________________________________________ 208


Collectors for forced circulation systems
SCF-V25 - TRAY COLLECTOR - 2,5m2 ___________________________________________________ 210
SCF-25B - COLLECTOR WITH SEALED ALUMINIUM FRAME - 2,5m2 ______________________________ 216
SCF-20B - COLLECTOR WITH SEALED ALUMINIUM FRAME - 2m2 ________________________________ 224
SCO-25B - HORIZONTAL COLLECTOR WITH SEALED ALUMINIUM FRAME - 2,5m2 ____________________ 230
SCI-25N - WOOD FRAME INSET COLLECTOR - 2,5m2 ________________________________________ 236
SCV-25 - EVACUATED TUBE COLLECTOR - 2,5m2 ___________________________________________ 242

Product matrix of solar cylinders and buffer tanks __________________________________ 248


Solar cylinders
IDRA MS/DS FI LE - WITH LOW ENERGY HYDRAULIC GROUP AND CONTROL-BOX _____________________ 250
IDRA MS - WITH INCREASED COIL SURFACE _______________________________________________ 252
IDRA DS - WITH INCREASED COIL SURFACE _______________________________________________ 254
IDRA N DS - WITH HIGH STORAGE CAPACITY ______________________________________________ 256
IDRA PLUS DS - FLANGED WITH HIGH STORAGE CAPACITY ____________________________________ 258

Multi-energy tanks
HYBRID STOR - WITH STAINLESS STEEL COIL FOR DHW ______________________________________ 260

Combined storage tanks


STOR C - TANK-IN-TANK _____________________________________________________________ 262

Buffer tanks
STOR M AND STOR - WITH COIL OR FLANGED _____________________________________________ 264

Heat exchange groups - solar side


STS 50 LOW ENERGY _______________________________________________________________ 266
STS 120 LOW ENERGY ______________________________________________________________ 267

Heat exchange groups - DHW


ACS 35 LOW ENERGY/ACS 40 LOW ENERGY ______________________________________________ 268
ACS 160 LOW ENERGY ______________________________________________________________ 270

Solar thermal accessories


ELECTRIC AND HYDRAULIC KITS _______________________________________________________ 271

Natural circulation systems


NB-SOL - COMPLETE NATURAL CIRCULATION SYSTEM _______________________________________ 274

19
SYSTEM DIAGRAMS
HYBRID SYSTEM FOR DHW PRODUCTION WITH SOLAR THERMAL AND DHW HEAT PUMP _______________ 278
HYBRID SYSTEM FOR THE PRODUCTION OF DHW (SOLAR THERMAL/BOILER)
AND HEATING/COOLING (HEAT PUMP/BOILER) _____________________________________________ 279
HYBRID SYSTEM FOR THE PRODUCTION OF DHW (SOLAR THERMAL/BOILER)
AND HEATING/COOLING (HEAT PUMP/BOILER) _____________________________________________ 280
HYBRID SYSTEM FOR DHW PRODUCTION AND SEPARATE HEATING/COOLING _______________________ 281
HYBRID SYSTEM FOR THE PRODUCTION OF DHW, HEATING AND COOLING
WITH THREE FLANGES CYLINDER ______________________________________________________ 282
HYBRID SYSTEM FOR THE PRODUCTION OF DHW, HEATING AND COOLING
WITH TRIPLE COIL HYBRID BUFFER TANK _________________________________________________ 283
HYBRID SYSTEM FOR THE PRODUCTION OF DHW, HEATING AND COOLING
WITH SINGLE COIL CYLINDER _________________________________________________________ 284
HYBRID SYSTEM FOR THE PRODUCTION OF DHW, HEATING AND COOLING
WITH TRIPLE COIL HYBRID BUFFER TANK _________________________________________________ 285
SYSTEM FOR THE PRODUCTION OF DHW AND HEATING WITH COMBI BOILER _______________________ 286
SYSTEM FOR THE PRODUCTION OF DHW AND HEATING WITH TWO CYLINDERS
CONNECTED IN PARALLEL ___________________________________________________________ 287
SYSTEM FOR THE PRODUCTION OF DHW AND HEATING WITH TWO SOLAR HYDRAULIC GROUPS __________ 288
SOLAR SYSTEM ON DOUBLE SLOPE FOR THE PRODUCTION OF DHW AND HEATING
WITH POWER PLUS BOX SE __________________________________________________________ 289
SYSTEM FOR THE PRODUCTION OF DHW AND HEATING
WITH POWER PLUS IN LINEAR CASCADE CONFIGURATION _____________________________________ 290
SYSTEM FOR THE PRODUCTION OF DHW AND HEATING
WITH POWER PLUS 50 kW STAND ALONE CONFIGURATION ____________________________________ 291
SYSTEM FOR THE PRODUCTION OF DHW, HEATING AND SWIMMING POOL
WITH SINGLE COIL CYLINDER _________________________________________________________ 292
SYSTEM FOR THE PRODUCTION OF DHW, HEATING AND SWIMMING POOL
WITH TRIPLE COIL MULTI-ENERGY TANK __________________________________________________ 293
SYSTEM FOR THE PRODUCTION OF DHW AND HEATING
WITH POWER PLUS IN LINEAR CASCADE CONFIGURATION _____________________________________ 294
HYBRID SYSTEM FOR THE PRODUCTION OF DHW AND HEATING
WITH SOLAR THERMAL SYSTEM AND TRIPLE COILS STORAGE TANK (HYBRID STOR) __________________ 295
HYBRID SYSTEM FOR THE PRODUCTION OF DHW AND HEATING
WITH SOLAR THERMAL SYSTEM AND TRIPLE COILS BUFFER TANK (HYBRID STOR) ____________________ 296
HYBRID SYSTEM FOR THE PRODUCTION OF DHW AND HEATING
WITH SOLAR THERMAL SYSTEM AND TWIN COIL CYLINDER ____________________________________ 297
HYBRID SYSTEM FOR THE PRODUCTION OF DHW AND HEATING
WITH SOLAR THERMAL SYSTEM AND COMBINED STORAGE TANK (TANK-IN-TANK) ____________________ 298
SOLAR THERMAL SYSTEM FOR DHW PRODUCTION IN COMBINATION
WITH AIR SOURCE HEAT PUMP FOR DHW AND CH SYSTEM ____________________________________ 299
‘BIVALENT’ TYPE SYSTEM WITH SOLAR THERMAL SYSTEM FOR DHW
PRODUCTION, AIR SOURCE HEAT PUMP AND CONDENSING GAS BOILER ___________________________ 300
‘BIVALENT’ TYPE SYSTEM WITH AIR SOURCE HEAT PUMP
AND BACK UP WITH WALL-HUNG ‘HEATING ONLY’ BOILER _____________________________________ 301
SOLAR THERMAL SYSTEM FOR DHW PRE-HEATING WITH MYNUTE GREEN CSI _______________________ 302

20
SOLAR THERMAL SYSTEM FOR THE PRODUCTION OF DHW
WITH INTEGRATION OF ‘HEATING ONLY’ BOILER ____________________________________________ 303
NATURAL CIRCULATION SOLAR SYSTEM FOR THE PRODUCTION OF DHW
WITH INTEGRATION OF A COMBI BOILER _________________________________________________ 304
SOLAR THERMAL SYSTEM FOR THE PRODUCTION OF DHW
AND HEATING SUPPLEMENT WITH COMBINED STORAGE TANK (STOR C) AND BOILER __________________ 305
SOLAR THERMAL SYSTEM FOR THE PRODUCTION OF DHW, HEATING SUPPLEMENT
AND SWIMMING POOL WITH COMBINED STORAGE TANK (STOR C) AND COMBI BOILER ________________ 306
SOLAR THERMAL SYSTEM FOR THE PRODUCTION OF DHW AND HEATING SUPPLEMENT
WITH BOILER, BIOMASS HEAT GENERATOR AND COMBINED STORAGE TANK (STOR C) _________________ 307
SOLAR THERMAL SYSTEM FOR THE PRODUCTION OF CENTRALIZED DHW
WITH BUFFER TANK AND BOILER INTEGRATION _____________________________________________ 308
SOLAR THERMAL SYSTEM ON DOUBLE SLOPE FOR THE PRODUCTION OF DHW
WITH IDRA CYLINDER AND INTEGRATION OF CENTRALIZED HEATING _____________________________ 309
SOLAR THERMAL SYSTEM FOR THE PRODUCTION OF DHW
AND HEATING SUPPLEMENT WITH TWO IDRA CYLINDERS _____________________________________ 310
SOLAR THERMAL SYSTEM FOR THE PRODUCTION OF CENTRALIZED DHW WITH BUFFER TANK
AND INTEGRATION OF POWER PLUS BOILERS IN CASCADE ____________________________________ 311

21
22
SYSTEMS
SMART
SMART
SYSTEMS

23
A SMARTER
T H E R M O S T A T.

Simple.
Universal.
Always with you.

... W i th B e S M A RT u s e r s c a n
adapt their heating to suit their
schedules and lifestyles.

Whether they are off on


h o l i d a y, o u t s h o p p i n g o r
just working late, BeSMART
gives them complete control
of their home comfort
via the handy App on a
smar tphone or tablet.

BeSMART is a clever way


to cut costs by matching
heating to dif ferent
lifestyles. Which
means only paying for
heating when people
are at home to feel
the benefit of it.

24
SYSTEMS
SMART
A S M A R T E R B O I L E R.

F r o m t h e e x p e r t s i n r e s i d e n t i a l h e a t i n g , t h e n e w b o i l e r M y S M A R T, c o m b i n i n g
Beretta top technology and smar t communication.
BeSMART with MySMART !
Beretta MySMART is standard equipped with the new Beretta WiFi thermostat
B e S M A R T, a l l o w i n g u s e r s t o e n j o y t h e h i g h e s t d e g r e e o f c o n n e c t i v i t y , i n a d d i t i o n
to comfor t management and boiler control via App.
Discover all product features in this section.

Download App

25
Systems for the home comfort management via smartphone and tablet
BeSMART

Ŷ Programmable WiFi thermostat for the complete control of your home comfort from
whereever you are, via your Smartphone and Tablet.
Ŷ Specifically engineered to compliment the Beretta boiler range, BeSMART is compatible(*)
with the majority of boiler brands on the market, also in WiFi configuration.
Ŷ Supplied with WiFi Box for connection to the ADSL home WiFi modem to access Internet.
Ŷ BeSMART App available free of charge (for iOS and Android ≥ version 3.0) to download
to your Smartphone and Tablet for the home comfort management from anywhere in the
world.
Ŷ Ideal replacement for old thermostats, not just Beretta, it is available also without WiFi box,
to be used as a traditional thermostat.
(89mm H x 135mm W x 28mm D) Ŷ Possibility to manage up to 8 different heating zones (non-mixed zones), from wherever
you are in the world, also via App.
Ŷ 3 temperature levels: comfort, economy, frost protection.
Ŷ 4 working modes: auto, manual, party, holiday.
Ŷ Cooling mode thermostat setting (also via App).
Ŷ Setting room temperature range from + 3°C to + 35°C, with 0,2°C increments (also via
App).
Ŷ Weekly central heating programming, at 30-minute intervals (also via App).
Ŷ Room temperature and outdoor temperature displayed (also on App).
Ŷ Low battery indicator icon (also on App).
Ŷ BeSMART outputs:
wired ON/OFF; wired OTBus; wireless ON/OFF; wireless OTBus.
Ŷ End-user account service on Beretta Cloud
Ŷ BeSMART is powered by 2 AA 1,5V batteries (included in the package). It therefore does
not require a fixed 230V mains power supply.

Exclusive to Beretta (**), additional TOP advantages by BeSMART:


(86mm H x 86mm W x 21mm D) Ŷ Complete control of home comfort and boiler - including DHW setting - also via App.
Ŷ Enhanced comfort and savings deriving from BeSMART working as modulating
programmable thermostat - also via App.
Ŷ Alerts notification and remote boiler reset - also via App.
Ŷ Possibility of online connection of your boiler to an authorized Beretta Service Centre
(check the availability of these additional services in your country with your local
distributor).

(*) when used as a WiFi programmable thermostat with boilers with ON/OFF control.
(**) provided that your Beretta boiler features OTBus - see the BeSMART compatible boilers matrix in
the following pages.

WIFI Programmable room thermostat

CODE DESCRIPTION and FUNCTIONS

BESMART WIFI CONTROL K IT


Complete kit for WiFi installation, in which the BeSMART Control and the WiFi Box are ‘pre-paired’.
2 0 1118 7 6 To be connected to Internet through ADSL home WiFi modem. Supplied with WiFi power supply,
boiler OT wiring kit, wall fixings, adhesive magnetic fixing, batteries and instructions.
CLASS - ErP CONTRIBUTION: VI - 4% (A); I - 1% (B)

BESMART CONTROL
Can be coupled to an existing BeSMART WiFi Box to enable multizone control.
Can also be used as a replacement for an old thermostat and be connected, also later, to the WiFi
2 0 1118 7 8 Box, to enable Internet connectivity.
Supplied with wall fixings, adhesive fixing, batteries and instructions.
CLASS - ErP CONTRIBUTION: V - 3% (A); I - 1% (B)

(A) When combined with Beretta ErP boilers.


(B) When combined with any boiler.

= NEW (the green rectangle identifies a new code)

26
Systems for the home comfort management via smartphone and tablet

SYSTEMS
SMART
BeSMART
BeSMART offers a wide range of optional accessories to satisfy most applications and specific installation requirements.
You will be surprised at the inherent simplicity and modularity of the BeSMART system.
For instance, you can start with a simple BeSMART Control, upgrade your system later on with WiFi connection to Internet and at a later stage expand it to
a complete multizone system. See the main application schemes of BeSMART in the following pages.

Specific accessories for BeSMART

CODE DESCRIPTION and FUNCTIONS

WIFI BOX
Enables internet connection of a BeSMART Control through the ADSL home WiFI modem, thereby allowing
2 0 1118 8 5 enhanced functionality via the BeSMART App.
Enables RF communication with BeSMART Control (up to 8 Controls in case of multizone system).
Supplied with wiring, magnetic fixing, WiFi box power supply and instructions.

BOILER RF RECEIVER
Pre-wired boiler RF receiver. Can be used to configure the BeSMART control into a standard RF
2 0 112 0 7 9 programmable thermostat. See scheme 7.
Can also be used in those occasions where the boiler location has a poor or absent WiFi signal. Supplied
with magnetic fixing.

PV E X TERNA L SENSOR K IT
Wireless ‘photovoltaic’ external sensor, that enables accurate reading of the external temperature to
2 0 112 0 8 0 be sent – wirelessly – to the boiler to activate the boiler thermoregulation. No batteries required as the
sensor incorporates a photovoltaic fuel cell. Supplied with fixings and pre-wired receiver with connector
for the boiler. See compatibility matrix in the following page.

WIFI ROUTER FOR SIM CARD


2 0 112 113 SIM card router, plugs directly into a 230V power socket to create a WIFI network and connect
BeSMARTto the internet – subject to network coverage. Ideal for second homes.
SIM data card necessary, not included.

WIFI E X TENDER
2 0 112 112 Extends and improves the WiFi signal in areas of your home where the WiFi signal strength is poor or
inadequate.

OTBUS INTERFACE BOARD


12 2 117 9 Interface board necessary to enable OTBus communication for some boiler ranges.
See compatibility matrix in the following page.

A LPHA 7D WIRELESS (*)


This RF Programmable room thermostat can be used in case of multizone configurations as an alternative
2 0 10 174 8 option to BeSMART Control. It is supplied as standard with a Wireless RF Receiver.
In case of multizone configuration with WiFi Box, it is not necessary to install the Wireless RF receiver.

OTBUS CONNECTOR
20008401 Connector necessary to enable OTBus communication with some boiler ranges.
See compatibility matrix in the following page.

(*) The Wireless RF Receiver, supplied as standard with Alpha 7D Wireless, can also be used in different ways, according to your BeSMART system needs:
(a) to activate in RF a zone valve, whose switch limit must be wired in the boiler.
(b) in case you have a WiFi Box and the ADSL home WiFi signal near the boiler is poor or inadequate, you can install the Wireless receiver in RF by connecting it to the
boiler instead the WiFi Box, while this last could be sited next to the ADSL home WiFi modem. In this case the Wireless RF Receiver would have the signal bridge function
in RF and the Alpha 7-day would be coupled to the WiFi Box by keeping the Wireless communication.

= NEW (the green rectangle identifies a new code)

27
Systems for the home comfort management via smartphone and tablet
BeSMART

A SMARTER
T H E R M O S TAT.



MANAGEMENT OF HOME CUT YOUR BILLS COMPATIBILITY MULTIZONE
COMFORT VIA SMARTPHONE With BeSMART, cut your bills BeSMART is the ideal solution Possibilty to manage up to 8
AND TABLET by taking total control of your also in case of replacement different heating zones from
Whether you’re off on holiday, home heating, wherever you of older thermostats. In fact, wherever you are in the world
out shopping or just working are. BeSMART is a clever way it is compatible as a WiFi via App, from your smartphone
late, you can manage your to cut costs by matching your programmable thermostat with or tablet. (RF/ Radio Frequency
home heating remotley via heating to your lifestyle. all boiler brands on the market communication among
the BeSMART App from your that have a simple ON/OFF BeSMART Controls - wireless
smartphone or tablet. control, not just Beretta. communication within 40m
distance).

FREE OF CHARGE APP MULTI-USERS APP WiFi 24 HOUR - 7 DAY


BeSMART App is downloadable BeSMART App enables multi- WiFi communication between PROGRAMMING
free of charge for Android users management of the the WiFi Box and the WiFi ADSL 24 hour weekly programming;
(≥ 3.0 version) and iOS for the heating, by sharing the same home modem router to connect possibility to choose among
operation and programming of password. That is, every your BeSMART to the internet. different pre-set programs.
your boiler wherever you are, member of your family, f.i., As an alternative to the ADSL
via smartphone and tablet. can control the heating from modem, possibility of internet
smartphone or tablet. connection through the specific
WiFi router for SIM card. (See
BeSMART accessories)

‰Š‹
3 COMFORT LEVELS CENTRAL HEATING COOLING DOMESTIC HOT WATER
Programme up to 3 comfort 24 HOUR PROGRAMMING 24 HOUR PROGRAMMING 24-HOUR PROGRAMMING
levels to suit your mood and 24 hour central heating 24 hour cooling programming, at 24-hour DHW programming, at
your pocket. programming, at 30 minutes 30 minutes intervals (if combined 30 minutes intervals (enabled via
intervals. with a heat pump). OTBus connection).

HOLIDAY FUNCTION OUTDOOR TEMPERATURE INDOOR TEMPERATURE PARTY FUNCTION


Enables to enter the number of Outdoor temperature can be Indoor temperature is displayed Enables unscheduled and
days you will be away on holiday, read by the outdoor sensor or on BeSMART or can be immediate activation of heating/
during which your heatgenerator from internet. If you set the monitored through the BeSMART cooling (comfort T3 temperature)
will work in order to keep an home location on the App of your App via Smartphone or Tablet. until the midnight of that day,
energy-saving temperature. smartphone or tablet, the outdoor without modifying the set
temperature can be read from program.
internet.

28
Systems for the home comfort management via smartphone and tablet

SYSTEMS
SMART
BeSMART
BESMART COMPATIBLE BOILERS
This matrix shows the compatibility of BeSMART with the current Beretta boilers.
A full list of Beretta compatible boilers (including old models) is available at www.besmart-home.com

In the following pages, you will find several schemes showing the main application solutions of BeSMART.
Unders each scheme are the codes of the components necessary to achieve that type of installation.

CONDENSING BOILERS STANDARD EFFICIENCY BOILERS

FLOOR-STANDING BOILERS

FLOOR-STANDING BOILERS
Exclusive BOILER GREEN HE
WALL-HUNG BOILERS

WALL-HUNG BOILERS
Mynute GREEN 50 R.S.I.
Mynute BOILER GREEN
Exclusive GREEN E

Tower GREEN HE
Mynute Sinthesi

Novella Maxima
Mynute GREEN

Quadra GREEN

Mynute Boiler

Novella RAP
Ciao GREEN

Novella RAI
MySMART

Mynute S
Exclusive

Quadra II
Ciao AT

Ciao S

Ciao
code 20111876
BESMART WIFI ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
CONTROL KIT
ON/OFF
code 20111876
BESMART WIFI ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
CONTROL KIT (A) (A) (A)
OTBus
code 20111878
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
BESMART CONTROL
ON/OFF

code 20111878

BESMART CONTROL ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
OTBus (A) (A) (B) (B) (B) (A) (B) (B) (B)

code 1221179

OTBus ■ ■ ■
INTERFACE BOARD

code 20008401

OTBus ■ ■ ■ ■ ■ ■
CONNECTOR (C) (C) (C) (C) (C) (C)

code 20112080
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
PV EXTERNAL
SENSOR KIT

(A) To enable OTBus connection with this boiler range, it is necessary the OTBus Interface Board (code 1221179).
(B) To enable OTBus connection with this boiler range, it is necessary the OTBus connector (code 20008401), in addition to the BeSMART CONTROL
(code 20111878).
(C) This code is necessary in addition only to BeSMART CONTROL (code 20111878), to enable OTBus connection with this boiler range.
In the BeSMART WIFI CONTROL KIT, the OTBus connector is included as standard in the package.

29
Systems for the home comfort management via smartphone and tablet
BeSMART
BESMART WIFI - single zone SCHEME 1

as UNIVERSAL WIFI PROGRAMMABLE THERMOSTAT ON/OFF control

The typical BeSMART ‘universal’ solution, ideal also for replacement.


This application can be used on all brands of boilers that have a simple ON/OFF control, not just Beretta.
Use the two existing wires to connect directly to the ON/OFF terminals of the BeSMART control.
Connect the BeSMART WiFi box to a power outlet, download the BeSMART App to your tablet or smartphone
(from the App Store or Google play) and follow the instructions to program your system.
Now you can start ‘surfing’ in the home comfort, from wherever you are. It couldn’t be simpler.

A A

230 V ADSL INTERNET

use the 2-wire volt-free install the WiFi Box ADSL WiFi modem (*) for download the BeSMART
ON/OFF contact originating where you want, home internet connection App to your smartphone
from the boiler, to connect concealed if you wish to Beretta CLOUD or tablet to control your
your BeSMART home comfort from
wherever you are

(*) In case the ADSL WiFi modem is not present, you can buy the “WIFI ROUTER FOR SIM CARD” (code 20112113), enabling internet connection via a SIM
data card. See BeSMART specific accessories.
NB: When replacing a thermostat that has more than two wires, identify the ‘switch’ wires and connect only them to the BeSMART ON/OFF terminals (do
not connect a Neutral supply).

single zone configuration

REFERENCE CODE QUANTITY DESCRIPTION

A 20111876 1 BeSMART WIFI CONTROL KIT

30
Systems for the home comfort management via smartphone and tablet

SYSTEMS
SMART
BeSMART
BESMART WIFI single zone SCHEME 2

as MODULATING WIFI PROGRAMMABLE THERMOSTAT via Beretta OTBus connection

Exclusive to Beretta, an advanced solution and enhanced service that is enabled via your boiler’s OTBus connection.
With BeSMART and Beretta OTBus, you will have a greater degree of connectivity: you can view your boiler’s operating conditions,
alerts, parameters, home and outdoor temperature and much more. You can even reset your boiler when needed. You also have the
possibility of online connection of your boiler to an authorized Beretta Service Centre (check the availability of this additional service
in your country with your local distributor).
Furthermore, BeSMART WiFi combined with Beretta boilers of latest generation enables to create, without additional optionals,
A+ Class systems (*).
Check the OTBus compatibilty for each boiler in the BeSMART compatible boilers matrix.
For older Beretta boilers, check on the site www.besmart-home.com which models are compatibleompatibl
blle w
b wi
with
ith
th O
OTBus.
TB
T Bus
u .

SYSTEM
install the WiFi Box
close to the boiler

230 V INTERNET

ADSL

2-wire connection download the BeSMART


to the OTBus App to your smartphone
ADSL WiFi modem(**)
or tablet and enjoy the
for home internet connection
TOP advantages offered
to Beretta CLOUD
by BeSMART and Beretta

(*) Check the product matrix of Beretta condensing boilers in this catalogue to see which models achieve A+ class system.
(**) In case the ADSL WiFi modem is not present, you can buy the “WIFI ROUTER FOR SIM CARD” (code 20112113), enabling internet connection via a SIM
data card. See BeSMART specific accessories.

single zone configuration

REFERENCE CODE QUANTITY DESCRIPTION

A 20111876 1 BeSMART WIFI CONTROL KIT

31
Systems for the home comfort management via smartphone and tablet
BeSMART
BESMART WIFI multi-zone SCHEME 3

as UNIVERSAL PROGRAMMABLE WIFI THERMOSTAT zone valve control and boiler ON/OFF control

Even in existing multi-zone systems, BeSMART is simple and universal.


BeSMART has a control relay for zone valve (max 0,25A at 230 V, or max 2 A at 24V).
Just replace each of the old thermostats with a BeSMART and connect the wires to the BeSMART output relay.
As an alternative option, an RF Programmable Room Thermostat can be used for each additional zone.
See BeSMART accessories.

2-wire relay contact


B

zone
valve

A A

zone
valve

230 V
B ADSL INTERNET

zone
valve

2 wire volt-free contact max 8 zones install the WiFi Box ADSL home WiFi download the BeSMART
for ON/OFF control and (non-mixed zones) where you want, modem(*) for internet App to your smartphone
zone valve switching concealed if connection to or tablet to control your
you wish Beretta CLOUD home zone comfort from
wherever you are

(*) I n case the ADSL WiFi modem is not present, you can buy the “WIFI ROUTER FOR SIM CARD” (code 20112113), enabling internet connection via a SIM
data card. See BeSMART specific accessories.
NB: When replacing a thermostat that has more than two wires, identify the ‘switch’ wires and connect only them to the BeSMART ON/OFF terminals (do not connect
a Neutral supply).

ex. configuration for 3 zones **

REFERENCE CODE QUANTITY DESCRIPTION

A 20111876 1 BeSMART WIFI CONTROL KIT

B 20111878 2 BeSMART CONTROL

(**) In case of 8 zones, for example, you would require 7 x code 20111878 (BeSMART Control), in addition to 1 x code 20111876 (BeSMART WIFI CONTROL KIT).

32
Systems for the home comfort management via smartphone and tablet

SYSTEMS
SMART
BeSMART
BESMART WIFI multi-zone SCHEME 4

as MODULATING WIFI PROGRAMMABLE THERMOSTAT zone valve control via Beretta OTBus connection

Even on multi-zone systems, with a Beretta boiler that is OTBus compatible, you can enable advanced service and benefit TOP
advantages. With BeSMART and Beretta OTBus, you will have a greater degree of connectivity: you can view your boiler’s operating
conditions, alerts, parameters, home and outdoor temperature and much more. You can even reset your boiler when needed. You
also have the possibility to connect online your boiler to an authorized Beretta Service Centre (check the availability of this additional
service in your country with your local distributor).
Furthermore, BeSMART WiFi combined with Beretta boilers of latest generation enables to create, without additional optionals,
A+ Class systems (*).
Check the OTBus compatibilty for each boiler in the BeSMART compatible boilers matrix.
For older Beretta boilers, check on the site www.besmart-home.com which models els are compatible
coom
mp
paattiib
blle with
w th OTBus.
wi

SYSTEM
2-wire relay contact 2-wire connection
to OTBus
B

zone
valve

zone A
valve

B
ADSL INTERNET
zone 230 V
valve

max 8 zones 2-wire volt-free install the WiFi ADSL home WiFi download the BeSMART
(non-mixed zones) contact to energize Box close to modem(**) for internet App to your smartphone
zone valves the boiler connection to or tablet and enjoy the
Beretta CLOUD TOP advantages offered
by BeSMART and Beretta

(*) Check the product matrix of Beretta condensing boilers in this catalogue to see which models achieve A+ class system.
(**) In case the ADSL WiFi modem is not present, you can buy the “WIFI ROUTER FOR SIM CARD” (code 20112113), enabling internet connection via a SIM
data card. See BeSMART specific accessories.
NB: When replacing a thermostat that has more than two wires, identify the ‘switch’ wires and connect only them to the BeSMART ON/OFF terminals (do
not connect a Neutral supply).

ex. configuration for 3 zones ***

REFERENCE CODE QUANTITY DESCRIPTION

A 20111876 1 BeSMART WIFI CONTROL KIT

B 20111878 2 BeSMART CONTROL

(***) In case of 8 zones, for example, you would require 7 x code 20111878 (BeSMART CONTROL), in addition to 1 x code 20111876 (BeSMART WIFI CONTROL KIT).

33
Systems for the home comfort management via smartphone and tablet
BeSMART
BESMART - single zone SCHEME 5

as UNIVERSAL PROGRAMMABLE THERMOSTAT ON/OFF control

If you are not interested in the home comfort management via Smartphone or Tablet, BeSMART can work also as a traditional
programmable thermostat.
This application is ideal also for replacement, as BeSMART is compatible with all brands of boilers that have an ON/OFF control.
Use the two existing wires to connect directly to the ON/OFF terminals of BeSMART control.

use the 2-wire volt-free


ON/OFF contact, originating
from the boiler, to connect
your BeSMART

NB: When replacing a thermostat that has more than two wires, identify the ‘switch’ wires and connect only them to the BeSMART ON/OFF terminals
(do not connect a Neutral supply).

single zone configuration

REFERENCE CODE QUANTITY DESCRIPTION

B 20111878 1 BeSMART CONTROL

34
Systems for the home comfort management via smartphone and tablet

SYSTEMS
SMART
BeSMART
BESMART - single zone SCHEME 6

as MODULATING PROGRAMMABLE THERMOSTAT via Beretta OTBus connection

Exclusive to Beretta, if you are not interested in the home comfort management via Smartphone or Tablet and your boiler is OTBus
compatible, BeSMART can work as a modulating programmable thermostat.
In addition, with BeSMART and Beretta OTBus, you will have a greater degree of connectivity: you can view your boiler’s operating
conditions, alerts, parameters, home and outdoor temperature and much more. You can also reset your boiler when needed.
Furthermore, BeSMART WiFi combined with Beretta boilers of latest generation enables to create, without additional optionals,
A+ Class systems (*).
Check the OTBus compatibilty for each boiler in the BeSMART compatible boilers matrix.
For older Beretta boilers, check on the site www.besmart-home.com which models are compatible
om
mppaati
tible wi
with OTBus.

SYSTEM

connect the 2-wire


OTBus contact to the
BeSMART Control

(*) Check the product matrix of Beretta condensing boilers in this catalogue to see which models achieve A+ class system.

single zone configuration

REFERENCE CODE QUANTITY DESCRIPTION

B 20111878 1 BeSMART CONTROL

35
Systems for the home comfort management via smartphone and tablet
BeSMART
BESMART - single zone SCHEME 7

as RF MODULATING PROGRAMMABLE THERMOSTAT via Beretta OTBus connection and RF receiver

Exclusive to Beretta, if your boiler is OTBus compatible and you are not interested in the home comfort management via Smartphone
or Tablet, BeSMART can work also as an RF wireless modulating programmable thermostat, while ensuring in addition all extensive
advantages from Beretta and OTBus: you can view your boiler’s operating conditions, alerts, parameters, home and outdoor temperature
and much more. You can also reset your boiler when needed.
The receiving range between BeSMART Control and the RF receiver is 40 metres, which is large enough for most household applications.
Anyway, in this RF configuration, BeSMART doesn’t need to be wall mounted, as it is powered by batteries.
Furthermore, BeSMART combined with Beretta boilers of latest generation enables to create, without additional optionals,
A+ Class systems (*).
Check the OTBus compatibilty for each boiler in the BeSMART compatible boilers matrix.
For older Beretta boilers, check on the site www.besmart-home.com which models delss aare
rree ccompatible
omp
ompaatibl with OTBus.

SYSTEM

C B

230 V

connect the 2-wire place BeSMART wherever you like


OTBus contact to the in your home; in RF configuration,
boiler RF receiver no need of wall-hung installation, as
BeSMART control is battery powered

(*) Check the product matrix of Beretta condensing boilers in this catalogue to see which models achieve A+ class system.

single zone configuration

REFERENCE CODE QUANTITY DESCRIPTION

B 20111878 1 BeSMART CONTROL

C 20112079 1 BOILER RF RECEIVER

36
Systems for the home comfort management via smartphone and tablet

SYSTEMS
SMART
MySMART

Ŷ MySMART, standard equipped with BeSMART WiFi Control kit,


achieves an A+ class system (without additional optionals).
Ŷ Free of charge App to download to smartphone or tablet
SYSTEM
for the boiler control and home comfort management, from
anywhere you are.
Ŷ Can be matched with BeSMART Control working as WiFi
Ø50-Ø60 thermostat in OTBus communication, allowing exstensive TOP
INSIDE CHIMNEY advantages.
Ŷ 10:1 modulation ratio, the highest range of modulation.
Ŷ New condensing aluminium heat-exchanger with high flow
INTERAXES AND HYDRAULIC rate and front access, assisting in simple maintenance.
FITTINGS POSITIONING
Central heating Gas Domestic water Ŷ Low emissions: class 5 (UNI EN 483).
R F G O I Ŷ Low Energy modulating circulator (EEI ≤ 0,20) with 6m head,
65 120 60 55 adjustable up to 7m.
Ŷ Thermoregulation as standard.
Ŷ Possibility of inside-chimney installation via specific flue
options in PP Ø80 (up to 140m), Ø60 (up to 26m) and Ø50
(up to 7m).
Ŷ Ø80mm twin system kit supplied as standard.
Ŷ Hydraulic cover supplied as standard.
Ŷ Supplied as standard: installation template with brackets, heating taps
with filter, hydraulic connections in brass, gas and DHW taps.
Ŷ Can be converted to LPG through LPG kit (available as option).

Premix condensing

DIMENSIONS CH/DHW DHW ENERGY CLASS


CODE GAS MODEL H ×W × D INPUT PRODUCTION
(mm) MIN - MAX (kW) (l/min. - Δt 25 °C)
COMBI BOILERS

2.80 - 20.00 /
20109808 NG MySMART 28 C.S.I. 780 × 400 × 365 16,1
2.80 - 28.00

= NEW (the green rectangle identifies a new code)

Accessories

CODE DESCRIPTION

Comfort accessories
20049748 Outdoor probe with connector

Hydraulic accessories
20035644 Solar diverter valve
20097192 Condensate pump
Special accessories
1220639 Limit thermostat for low temperature applications

37
38
CONDENSING
BOILERS
CONDENSING
BOILERS

39
Wall-hung boilers
PRODUCT MATRIX OF BERETTA CONDENSING BOILERS

PRODUCT SYSTEM COMBI


ENERGY CLASS ENERGY CLASS MODELS

NEW MySMART (*) XL SYSTEM 28 (NG)

25 (NG)
EXCLUSIVE SYSTEM
XL 30 (NG)
GREEN E
with optional kit (1) 35 (NG)

XL 25 (NG - LPG)
MYNUTE
30 (NG)
GREEN
with INSTANTANEOUS DHW PRODUCTION

non ErP compliant (**) 38 (NG)

XL
SYSTEM
25 (NG - LPG)
CIAO GREEN
29 (NG)
non ErP compliant (**) with optional kit (2)

XL
QUADRA SYSTEM
25 (NG)
GREEN 30 (NG)
non ErP compliant (**) with optional kit (3)

MYNUTE 25 (NG)
B XL
SINTHESI (4) 29 (NG)

25 (NG)
NEW CIAO AT (4) B XL 29 (NG)

_
MYNUTE _
GREEN 50 R.S.I.
non ErP compliant (**)
with BUILT-IN DHW TANK

EXCLUSIVE 25 (NG)
XL
BOILER GREEN HE 35 (NG)

25 (NG)
XL
MYNUTE
BOILER GREEN 32 (NG)
non ErP compliant (**)

(*) MySMART is treated in the section ‘Smart systems’.


(**) According to the European Directive ERP, these products are not allowed to be placed on the European market by the manufacturer since 01/08/2015.
(1) In combination with BeSMART Control (codes 20111876 or 20111878) Exclusive Green E range (except for 35kW models) achieves A+ system.
(2) Ciao Green boiler range, in case of multizone systems with at least 3 zones, achieves A+ class system if combined with 3 pcs. of BeSMART Control
(codes 20111876 or 20111878).

40
‘HEATING-ONLY’ COMBUSTION DHW BeSMART WIFI MODULATION CIRCULATOR
MODELS PRODUCTION RANGE HEAD

CONDENSING
BOILERS
modulating,
_ via stainless steel compatible
premix 10 : 1 with 6m head,
DHW heat-exchanger (included as standard)
adjustable up to 7m

25 (NG) modulating,
via stainless steel compatible
- premix 10 : 1 with 6m head,
DHW heat-exchanger (as option)
35 (NG) adjustable up to 7m

12, 15, 20, 25, 35


(NG)
via stainless steel compatible
premix 5:1 6m
DHW heat-exchanger (as option)
12, 15, 25, 35
(NG)

25 (NG - LPG) via stainless steel compatible


premix 5:1 6m
DHW heat-exchanger (as option)

25 (NG) via stainless steel compatible


premix 5:1 6m
DHW heat-exchanger (as option)

_ with post via stainless steel compatible


2:1 6m
heat-exchanger DHW heat-exchanger (as option)

_ with post via stainless steel compatible


2:1 6m
heat-exchanger DHW heat-exchanger (as option)

_ compatible
50 (NG) premix 5:1 7m
(as option)

via stainless steel modulating,


_ compatible
premix DHW tank 10 : 1 with 6m head,
(as option)
(60 litres capacity) adjustable up to 7m

via stainless steel modulating,


_ compatible
premix DHW tank 5:1 with 6m head,
(as option)
(45/60 litres capacity) adjustable up to 7m

(3) Quadra Green boiler range, in case of multizone systems with at least 3 zones, achieves A+ class system if combined with 3 pcs. of BeSMART
Control (codes 20111876 or 20111878).
(4) This boiler range, being provided with post heat-exchanger, is specifically suitable for high temperature circuits (with radiators, etc.)

41
Combi and ‘heating-only’ wall-hung boilers
EXCLUSIVE GREEN E

■■EXCLUSIVE GREEN E is Beretta top of the range condensing


appliance and one of the most energy efficient boilers available
on the market.
SYSTEM ■■In combination with the external probe (as standard) and
BeSMART WiFi (as an accessory), Exclusive Green E (except for
35kW models) enables to create an A+ system.
Ø50 ■■New, frontal access, condensing heat-exchanger in extruded
aluminium assists in simple maintenance.
19 m ■■Low NOx: Class 5 according to European Directive UNI EN 483.
■■Low Energy, A-Class, synchronous modulating pump (EEI ≤ 0.20),
PWM controlled (6 metres residual head adjustable from 4 metres to 7
INTERAXES AND HYDRAULIC metres) with different working options and selectable velocities.
FITTINGS POSITIONING ■■10 : 1 premix modulation ratio, the highest range of modulation.
Central heating Gas Domestic water
■■ErP seasonal space heating energy efficiency 94% (93% on 35kW
R F G O I
models).
65 120 60 55
■■Built-in thermoregulation with external probe supplied as standard.
■■Lower hydraulic connections cover supplied as standard, to ensure a tidy
installation).
■■Widest variety of flue options for inside-chimney installation, including
BERETTA HIGH-EFFICIENCY
Ø50 on all models. Maximum extension lengths on 25kW model: Ø60
flue range in plastic PP (up to 23m), Ø50 in PPs, H1 Class (up to 19m)
and Ø80 in PP, H1 Class (up to 285m).
■■Clapet for collective flue positive pressure chimney - non-return
valve on flue side (available as option).
■■Hydraulic fittings supplied as standard (gas tap, cold water tap, copper
pipe connections with brass nipples).
■■ Can be converted to LPG through LPG kit (available as option).
■■Can be matched with BeSMART Control working as WiFi
thermostat in OTBus communication, allowing exstensive TOP
advantages.

Premix condensing

DIMENSIONS CH/DHW DHW ENERGY CLASS


CODE GAS MODEL H × W × D INPUT PRODUCTION
(mm) MIN - MAX (kW) (l/min. - ∆t 25 °C)
INSTANTANEOUS COMBI BOILERS

EXCLUSIVE GREEN E 2.80 - 20.00 /


20104060 NG 845 × 400 × 358 14,3
25 C.S.I. 2.80 - 25.00
EXCLUSIVE GREEN E 3.20 - 25.00 /
20104061 NG 845 × 450 × 358 17,2
30 C.S.I. 3.20 - 30.00
EXCLUSIVE GREEN E 3.60 - 30.00 /
20106641 NG 845 × 450 × 385 19,8
35 C.S.I. 3.60 - 34.60

HEATING ONLY BOILERS*

EXCLUSIVE GREEN E 2.80 - 20.00 /


20104062 NG 845 × 400 × 358 - -
25 R.S.I. 2.80 - 25.00
EXCLUSIVE GREEN E 3.60 - 30.00 /
20106642 NG 845 × 450 × 385 - -
35 R.S.I. 3.60 - 34.60
* The “heating only” models are supplied with a three-ways valve. Filling tap not available.

42
Combi and ‘heating-only’ wall-hung boilers
EXCLUSIVE GREEN E

Comfort accessories for smartphone and tablet *

CONDENSING
BOILERS
CODE DESCRIPTION

20111876 BeSMART WIFI CONTROL KIT (1)


20111878 BeSMART CONTROL (2)

(*) For all information about BeSMART and its wide range of accessories, please refer to the first chapter of this catalogue “SMART SYSTEMS”.
(1) Complete kit for WiFi installation.
(2) Only BeSMART thermostat.

= NEW (the green rectangle identifies a new code)

Other accessories

CODE DESCRIPTION

Comfort accessories
20059641 ALPHA DGT WIRELESS digital room thermostat
20059639 ALPHA DGT digital room thermostat
20101748 ALPHA 7D WIRELESS 7-day digital room thermostat
20063872 ALPHA 7D 7-day digital room thermostat
1221179 OTBus interface board
Hydraulic accessories
1101989 Heating taps
1101999 Heating taps with filter
20035644 Solar diverter valve
1220599 Socket probe for DHW tank - 3 m wire (only R.S.I. models)
20097192 Condensate pump
Special accessories
1220639 Limit thermostat for low temperature applications
20042454 Kit relé remote alarm
20100893 Kit clapet (for collective flue positive pressure chimney)

= NEW (the green rectangle identifies a new code)

43
Combi wall-hung boilers with built-in DHW tank
EXCLUSIVE BOILER GREEN HE
Ŷ EXCLUSIVE BOILER GREEN HE is Beretta top of the range
condensing appliance with built-in tank and one of the most
energy efficient boilers available on the market.
Ŷ Built-in stainless steel DHW tank (60 litres capacity) with
magnesium anode.
Ŷ Low Energy, A-Class, synchronous pump (EEI ≤ 0.23), PWM
controlled (4 mt on 25 B.S.I. and 6 mt on 35 B.S.I.) with different
working options.
INTERAXES AND HYDRAULIC Ŷ 10 : 1 modulation ratio, the highest range of modulation.
FITTINGS POSITIONING
Central heating Gas Domestic water Ŷ The RANGE RATED certification allows to adapt the power of the boiler
R F G O RC I to the real thermal requests of the installation.
65 85 108 90 90 Ŷ Lowest electrical consumption (only 66 Watt on 25 B.S.I.).
Ŷ 10 lt. expansion vessel.
Ŷ Low NOx (Class 5 according to European Directive UNI EN 483).
Ŷ Condensing heat-exchanger in extruded aluminium providing excellent
thermal transfer.
Ŷ Built-in thermoregulation with external probe supplied as standard.
BERETTA HIGH-EFFICIENCY Ŷ IPX5D electrical protection.
Ŷ Exclusive BOILER GREEN HE can be converted to LPG through LPG kit
supplied as standard.
Ŷ Can be matched with BeSMART Control working as WiFi
thermostat in OTBus communication, allowing exstensive TOP
advantages.

Premix condensing

DIMENSIONS INPUT DHW TANK ENERGY CLASS


CODE GAS MODEL H ×W × D MIN - MAX CAPACITY
(mm) (kW) (litres)
COMBI BOILERS WITH BUILT-IN DHW TANK

EXCLUSIVE BOILER
20023094 NG 940 × 600 × 450 2.50 - 25.00 60
GREEN HE 25 B.S.I.
EXCLUSIVE BOILER
20031609 NG 940 × 600 × 450 3.50 - 34.60 60
GREEN HE 35 B.S.I.

44
Combi wall-hung boilers with built-in DHW tank
EXCLUSIVE BOILER GREEN HE

Comfort accessories for smartphone and tablet *

CONDENSING
BOILERS
CODE DESCRIPTION

20111876 BeSMART WIFi CONTROL KIT (1)


20111878 BeSMART CONTROL (2)

(*) For all information about BeSMART and its wide range of accessories, please refer to the first chapter of this catalogue “SMART SYSTEMS”.
(1) Complete kit for WiFi installation.
(2) Only BeSMART thermostat.

= NEW (the green rectangle identifies a new code)

Other accessories

CODE DESCRIPTION

Comfort accessories
20059641 ALPHA DGT WIRELESS digital room thermostat
20059639 ALPHA DGT digital room thermostat
20101748 ALPHA 7D WIRELESS 7-day digital room thermostat
20063872 ALPHA 7D 7-day digital room thermostat
1221179 OTBus interface board
Hydraulic accessories
1101989 Heating taps
1101999 Heating taps with filter
20082453 A-Class Low Energy synchronous pump, PWM controlled (7 metres)
1103479 DHW recirculation kit
20097192 Condensate pump
Special accessories
1220639 Limit thermostat for low temperature applications

45
Combi and ‘heating-only’ wall-hung boilers
MYNUTE GREEN

Ŷ On ErP boilers: Low Energy, A-Class, modulating pump


EEI ≤ 0.23, PWM controlled.
Ŷ 5 : 1 modulation ratio.
Ŷ The RANGE RATED certification allows to adapt the power of the boiler
to the real thermal requests of the installation.
Ŷ Low NOx (Class 5 according to European Directive UNI EN 483).
Ŷ Condensing heat-exchanger in extruded aluminium providing excellent
INTERAXES AND HYDRAULIC thermal transfer.
FITTINGS POSITIONING Ŷ Built-in thermoregulation (with external probe available as option).
Central heating Gas Domestic water
Ŷ Ideal for low-temperature installations.
R F G O I
65 120 60 55
Ŷ IPX5D electrical protection.
Ŷ Built-in clapet for collective flue positive pressure chimney
- non-return valve on flue side (only 25 C.S.I. and 25 R.S.I.
models).
Ŷ Can be matched with BeSMART Control working as WiFi
thermostat in OTBus communication, allowing exstensive TOP
advantages.

Premix condensing

DIMENSIONS CH/DHW DHW ENERGY CLASS


CODE GAS MODEL H ×W × D INPUT PRODUCTION
(mm) MIN - MAX (kW) (l/min. - Δt 25 °C)
INSTANTANEOUS COMBI BOILERS

MYNUTE GREEN 6.00 - 25.00 /


20095557 NG 780 × 400 × 358 14.3
25 C.S.I. E 6.00 - 25.00
MYNUTE GREEN 6.00 - 25.00 /
20095560 LPG 780 × 400 × 358 14.3
25 C.S.I. E 6.00 - 25.00
MYNUTE GREEN 6.00 - 30.00 /
20095561 NG 780 × 450 × 358 17.2
30 C.S.I. E 6.00 - 30.00
MYNUTE GREEN 7.00 - 30.00 /
20095562 NG 780 × 450 × 358 21.8
38 C.S.I. E 7.00 - 38.00

HEATING ONLY BOILERS*

MYNUTE GREEN 2.50 - 12.00 /


20095564 NG 780 × 400 × 358 - -
12 R.S.I. E 2.50 - 12.00
MYNUTE GREEN 3.50 - 15.00 /
20095565 NG 780 × 400 × 358 - -
15 R.S.I. E 3.50 - 15.00
MYNUTE GREEN 6.00 - 20.00 /
20111453 NG 780 × 400 × 358 - -
20 R.S.I. E 6.00 - 20.00
MYNUTE GREEN 6.00 - 25.00 /
20095559 NG 780 × 400 × 358 - -
25 R.S.I. E 6.00 - 25.00
MYNUTE GREEN 7.00 - 34.60 /
20095566 NG 780 × 450 × 358 - -
35 R.S.I. E 7.00 - 34.60

* The “heating only” models are supplied with a three-ways valve. Filling tap not available.

= NEW (the green rectangle identifies a new code)

46
Combi and ‘heating-only’ wall-hung boilers
MYNUTE GREEN
According to the European Directive ERP, the following products are not allowed
Premix condensing to be placed on the European market by the manufacturer since 01/08/2015

CONDENSING
DIMENSIONS CH/DHW DHW

BOILERS
CODE GAS MODEL H ×W × D INPUT PRODUCTION
(mm) MIN - MAX (kW) (l/min. - Δt 25 °C)
INSTANTANEOUS COMBI BOILERS
MYNUTE GREEN 6.00 - 25.00 /
20068937 NG 780 × 400 × 358 14.3
25 C.S.I. E 6.00 - 25.00
MYNUTE GREEN 6.00 - 25.00 /
20068942 LPG 780 × 400 × 358 14.3
25 C.S.I. E 6.00 - 25.00
MYNUTE GREEN 6.00 - 30.00 /
20068948 NG 780 × 450 × 358 17.2
30 C.S.I. E 6.00 - 30.00
MYNUTE GREEN 7.00 - 30.00 /
20068949 NG 780 × 450 × 358 21.8
38 C.S.I. E 7.00 - 38.00
HEATING ONLY BOILERS*
MYNUTE GREEN 2.50 - 12.00 /
20068933 NG 780 × 400 × 358 -
12 R.S.I. E 2.50 - 12.00
MYNUTE GREEN 3.50 - 15.00 /
20084045 NG 780 × 400 × 358 -
15 R.S.I. E 3.50 - 15.00
MYNUTE GREEN 6.00 - 25.00 /
20068940 NG 780 × 400 × 358 -
25 R.S.I. E 6.00 - 25.00
MYNUTE GREEN 7.00 - 34.60 /
20068950 NG 780 × 450 × 358 -
35 R.S.I. E 7.00 - 34.60
* The “heating only” models are supplied with a three-ways valve. Filling tap not available.

Comfort accessories for smartphone and tablet *

CODE DESCRIPTION CODE DESCRIPTION

20111876 BeSMART WIFI CONTROL KIT (1) 20111878 BeSMART CONTROL (2)

(*) For all information about BeSMART and its wide range of accessories, please refer to the first chapter of this catalogue “SMART SYSTEMS”.
(1) Complete kit for WiFi installation.
(2) Only BeSMART thermostat.
= NEW (the green rectangle identifies a new code)

Other accessories

CODE DESCRIPTION CODE DESCRIPTION

Comfort accessories 20105959 High head Low Energy pump (7 metres) - for ErP boilers
20059641 ALPHA DGT WIRELESS digital room thermostat 20008794 Kit hydraulic connections (for welding)
20059639 ALPHA DGT digital room thermostat 20051979 Kit hydraulic connections (with brass nipples)
20101748 ALPHA 7D WIRELESS 7-day digital room thermostat 20035644 Solar diverter valve
20063872 ALPHA 7D 7-day digital room thermostat Socket probe for DHW tank -
1220599
3 m wire (only R.S.I. models)
Hydraulic accessories
20097192 Condensate pump
1101989 Heating taps
Special accessories
1101999 Heating taps with filter
1220639 Limit thermostat for low temperature applications
High head pump (6 metres) -
1101979
only model 12 kW - for non-ErP boilers
1102009 Ultra high head pump (7 metres) - for non-ErP boilers

47
Combi wall-hung boilers with built-in DHW tank
MYNUTE BOILER GREEN

Ŷ Built-in stainless steel DHW tank with magnesium anode


(capacity: 45 lt. on 25 B.S.I. E model; 60 lt. on 32 B.S.I. E
model).
Ŷ On ErP boilers: Low Energy, A-Class, synchronous pump
EEI ≤ 0.20 (6 metres residual head adjustable from 4 metres to
INTERAXES AND HYDRAULIC
7 metres).
FITTINGS POSITIONING Ŷ The RANGE RATED certification allows to adapt the power of the
Central heating Gas Domestic water
boiler to the real thermal requests of the installation.
R F G O RC I Ŷ Low NOx (Class 5 according to European Directive UNI EN 483).
65 85 108 90 90
Ŷ Condensing heat-exchanger in extruded aluminium providing
excellent thermal transfer.
Ŷ Built-in thermoregulation (with external probe available as
option).
Ŷ Ideal for low-temperature installations.
Ŷ IPX5D electrical protection.
Ŷ Can be matched with BeSMART Control working as
WiFi thermostat in OTBus communication, allowing
exstensive TOP advantages.

Premix condensing

DIMENSIONS CH/DHW DHW ENERGY CLASS


CODE GAS MODEL H ×W × D INPUT TANK CAPACITY
(mm) MIN - MAX (kW) (litres)
INSTANTANEOUS COMBI BOILERS

MYNUTE BOILER GREEN 6.00 - 25.00 /


20096189 NG 940 × 600 × 450 45
25 B.S.I. E 6.00 - 25.00
MYNUTE BOILER GREEN 6.00 - 25.00 /
20096190 NG 940 × 600 × 450 60
32 B.S.I. E 6.00 - 32.00

According to the European Directive ERP, the following products are not allowed
Premix condensing to be placed on the European market by the manufacturer since 01/08/2015

DIMENSIONS CH/DHW DHW


CODE GAS MODEL H ×W × D INPUT TANK CAPACITY
(mm) MIN - MAX (kW) (litres)
INSTANTANEOUS COMBI BOILERS

MYNUTE BOILER GREEN 6.00 - 25.00 /


20074589 NG 940 × 600 × 450 45
25 B.S.I. E 6.00 - 25.00
MYNUTE BOILER GREEN 6.00 - 25.00 /
20074847 NG 940 × 600 × 450 60
32 B.S.I. E 6.00 - 32.00

48
Combi wall-hung boilers with built-in DHW tank
MYNUTE BOILER GREEN

Comfort accessories for smartphone and tablet *

CONDENSING
BOILERS
CODE DESCRIPTION

20111876 BeSMART WIFI CONTROL KIT (1)


20111878 BeSMART CONTROL (2)

(*) For all information about BeSMART and its wide range of accessories, please refer to the first chapter of this catalogue “SMART SYSTEMS”.
(1) Complete kit for WiFi installation.
(2) Only BeSMART thermostat.

= NEW (the green rectangle identifies a new code)

Other accessories

CODE DESCRIPTION

Comfort accessories
20059641 ALPHA DGT WIRELESS digital room thermostat
20059639 ALPHA DGT digital room thermostat
20101748 ALPHA 7D WIRELESS 7-day digital room thermostat
20063872 ALPHA 7D 7-day digital room thermostat
20049748 Outdoor probe with connector
Hydraulic accessories
1101989 Heating taps
1101999 Heating taps with filter
1102009 Ultra high head pump (7 metres) - for non-ErP boilers
1103479 DHW recirculation kit
20097192 Condensate pump
20085814 Hydraulic connection kit and gas/DHW taps
Special accessories
1220639 Limit thermostat for low temperature applications

49
Combi and ‘heating-only’ wall-hung boilers
CIAO GREEN

Ŷ On ErP boilers: Low Energy, A-Class, synchronous pump EEI ≤


0.20 (6 metres).
Ŷ System energy class A+ in combination with BeSMART, in
installation with at least 3 zones.
Ŷ A cost-conscious condensing boiler with compact dimensions
and low lift weight, enabling a flexible installation anywhere in
the home.
INTERAXES AND HYDRAULIC Ŷ 5 : 1 modulation ratio.
FITTINGS POSITIONING
Central heating Gas Domestic water
Ŷ The RANGE RATED certification allows to adapt the power of the boiler
R F G O I
to the real thermal requests of the installation.
65 120 60 55 Ŷ Stylish and easy-to-use control panel with a digital display signalling
the boiler working status and the self-diagnostic.
Ŷ CIAO GREEN can be converted to LPG through specific LPG kit (as
option).
Ŷ Installation 3CEP available with specific flue kit.
Ŷ Can be matched with BeSMART Control working as WiFi
thermostat in OTBus communication, allowing exstensive TOP
advantages.

Premix condensing

DIMENSIONS CH/DHW DHW ENERGY CLASS


CODE GAS MODEL H ×W × D INPUT PRODUCTION
(mm) MIN - MAX (kW) (l/min. - Δt 25 °C)
INSTANTANEOUS COMBI BOILERS

CIAO GREEN 5.00 - 20.00 /


20095434 NG 715 × 405 × 250 14.3
25 C.S.I. 5.00 - 25.00
CIAO GREEN 5.00 - 20.00 /
20095437 LPG 715 × 405 × 250 14.3
25 C.S.I. 5.00 - 25.00
CIAO GREEN 6.00 - 25.00 /
20095435 NG 715 × 405 × 250 16.6
29 C.S.I. 6.00 - 29.00
HEATING ONLY BOILERS*
CIAO GREEN 5.00 - 20.00 /
20095432 NG 715 × 405 × 250 - -
25 R.S.I. 5.00 - 25.00
* The “heating only” models are supplied with a three-ways valve. Filling tap not available.

According to the European Directive ERP, the following products are not allowed
Premix condensing to be placed on the European market by the manufacturer since 01/08/2015

DIMENSIONS CH/DHW DHW


CODE GAS MODEL H ×W × D INPUT PRODUCTION
(mm) MIN - MAX (kW) (l/min. - Δt 25 °C)

INSTANTANEOUS COMBI BOILERS

CIAO GREEN 5.00 - 20.00 /


20035994 NG 715 × 405 × 250 14.3
25 C.S.I. 5.00 - 25.00
CIAO GREEN 5.00 - 20.00 /
20066454 LPG 715 × 405 × 250 14.3
25 C.S.I. 5.00 - 25.00
CIAO GREEN 6.00 - 25.00 /
20062778 NG 715 × 405 × 250 16.6
29 C.S.I. 6.00 - 29.00
HEATING ONLY BOILERS*
CIAO GREEN 5.00 - 20.00 /
20062776 NG 715 × 405 × 250 -
25 R.S.I. 5.00 - 25.00
* The “heating only” models are supplied with a three-ways valve. Filling tap not available.

50
Combi and ‘heating-only’ wall-hung boilers
CIAO GREEN

Comfort accessories for smartphone and tablet *

CONDENSING
BOILERS
CODE DESCRIPTION

20111876 BeSMART WIFI CONTROL KIT (1)


20111878 BeSMART CONTROL (2)
(*) For all information about BeSMART and its wide range of accessories, please refer to the first chapter of this catalogue “SMART SYSTEMS”.
(1) Complete kit for WiFi installation.
(2) Only BeSMART thermostat.

Other accessories

CODE DESCRIPTION

Comfort accessories
20059641 ALPHA DGT WIRELESS digital room thermostat
20059639 ALPHA DGT digital room thermostat
20101748 ALPHA 7D WIRELESS 7-day digital room thermostat
20063872 ALPHA 7D 7-day digital room thermostat
20049748 Outdoor probe with connector
Hydraulic accessories
1101989 Heating taps
1101999 Heating taps with filter
20008794 Kit hydraulic connections (for welding)
20008795 Kit hydraulic connections (with brass nipples)
1102009 Ultra high head pump (7 metres) - for non-ErP boilers
20105959 High head Low Energy pump (7 metres) - for ErP boilers
1220599 Socket probe for DHW tank - 3 m wire (only R.S.I. models)
20035644 Solar diverter valve
20097192 Condensate pump
Special accessories
1220639 Limit thermostat for low temperature applications
20012594 Hydraulic connections lower cover
20012595 Upper cover
20017044 Frost protection resistances kit till -10°C (C.S.I. models) (*)
20104420 Frost protection resistances kit till -10°C (R.S.I. models) (*)
20039567 Frost protection resistances for siphon
20084332 Dummy Ciao Green for POS
(*) The installation of frost protection resistances for C.S.I. models (code 20017044) and for R.S.I. models (code 20104420) must be made togheter with the siphon frost
protection (code 20039567) and the hydraulic connection lower cover (code 20012594).

= NEW (the green rectangle identifies a new code)


51
Combi and ‘heating-only’ wall-hung boilers (with new DIN connections)
QUADRA GREEN

Ŷ On ErP boilers: Low Energy, A-Class, synchronous pump


EEI ≤ 0.20.
Ŷ A cost-conscious condensing boiler with compact dimensions
and low lift weight, enabling a flexible installation anywhere in
the home.
Ŷ 5 : 1 modulation ratio.
Ŷ The RANGE RATED certification allows to adapt the power of the boiler
INTERAXES AND HYDRAULIC to the real thermal requests of the installation.
FITTINGS POSITIONING Ŷ Pump positioned on the right side.
CH DHW Gas DHW CH
Ŷ NEW DIN connections to facilitate any replacement or
F O G I R
new installation in buildings with the same connections
65 120 60 55
configuration.
Ŷ Stylish and easy-to-use control panel with a digital display and 3-LEDs
signalling the boiler working status and the self-diagnostic.
Ŷ Built-in thermoregulation (with external probe available as option).
Ŷ QUADRA GREEN can be converted to LPG through specific LPG kit (as
option).
Ŷ Installations 3CEP available with specific flue kit.
Ŷ Can be matched with BeSMART Control working as WiFi
thermostat in OTBus communication, allowing exstensive TOP
advantages.

Premix condensing

DIMENSIONS CH/DHW DHW ENERGY CLASS


CODE GAS MODEL H ×W × D INPUT PRODUCTION
(mm) MIN - MAX (kW) (l/min. - Δt 25 °C)
INSTANTANEOUS COMBI BOILERS
QUADRA GREEN 5.00 - 20.00 /
20095438 NG 715 × 405 × 250 14.3
25 C.S.I. 5.00 - 25.00
QUADRA GREEN 6.00 - 25.00 /
20095440 NG 715 × 405 × 250 16.6
30 C.S.I. 6.00 - 29.00
HEATING ONLY BOILERS*
QUADRA GREEN 5.00 - 20.00 /
20095439 NG 715 × 405 × 250 - -
25 R.S.I. 5.00 - 25.00
* The “heating only” models are supplied with a three-ways valve. Filling tap not available.

According to the European Directive ERP, the following products are not allowed
Premix condensing to be placed on the European market by the manufacturer since 01/08/2015

DIMENSIONS CH/DHW DHW


CODE GAS MODEL H ×W × D INPUT PRODUCTION
(mm) MIN - MAX (kW) (l/min. - Δt 25 °C)
INSTANTANEOUS COMBI BOILERS
QUADRA GREEN
20084406 NG 715 × 405 × 250 5.00 - 20.00 14.3
25 C.S.I.
QUADRA GREEN
20088858 NG 715 × 405 × 250 6.00 - 25.00 16.6
30 C.S.I.
HEATING ONLY BOILERS*
QUADRA GREEN
20084408 NG 715 × 405 × 250 5.00 - 20.00 -
25 R.S.I.
* The “heating only” models are supplied with a three-ways valve. Filling tap not available.

52
Combi and ‘heating-only’ wall-hung boilers (with new DIN connections)
QUADRA GREEN

Comfort accessories also for smartphone and tablet *

CONDENSING
BOILERS
CODE DESCRIPTION

20111876 BeSMART WIFI CONTROL KIT (1)


20111878 BeSMART CONTROL (2)

(*) For all information about BeSMART and its wide range of accessories, please refer to the first chapter of this catalogue “SMART SYSTEMS”.
(1) Complete kit for WiFi installation.
(2) Only BeSMART thermostat.

= NEW (the green rectangle identifies a new code)

Other accessories

CODE DESCRIPTION

Comfort accessories
20059641 ALPHA DGT WIRELESS digital room thermostat
20059639 ALPHA DGT digital room thermostat
20101748 ALPHA 7D WIRELESS 7-day digital room thermostat
20063872 ALPHA 7D 7-day digital room thermostat
20049748 Outdoor probe with connector
Hydraulic accessories
1101989 Heating taps
1101999 Heating taps with filter
20008794 Kit hydraulic connections (for welding)
20008795 Kit hydraulic connections (with brass nipples)
1102009 Ultra high head pump (7 metres) - for non-ErP boilers
20105959 High head Low Energy pump (7 metres) - for ErP boilers
1220599 Socket probe for DHW tank - 3 m wire (only R.S.I. models)
20035644 Solar diverter valve
1100509 Gas tap ¾” right-angle
20086186 Brass hydraulic fittings combi: CH tap, CH tap with filter, gas tap, cold water tap, hot water bend
20086187 Brass hydraulic fittings combi: 2 x ¾” brass CH bend, gas tap, cold water tap, 1 x ½” hot water bend
20086189 Brass hydraulic fittings heating only: CH tap, CH tap with filter, gas tap, 2 x ¾” brass tank bends
20086188 Brass hydraulic fittings heating only: 4 x ¾” brass CH and tank bends, gas tap
20077607 Brass hydraulic fittings combi: 2 x ¾” CH taps, 1 x ¾” gas bend, cold water tap, hot water bend
20097192 Condensate pump
Special accessories
1220639 Limit thermostat for low temperature applications
20012594 Hydraulic connections lower cover
20012595 Upper cover

53
Combi wall-hung boilers for high temperature systems
MYNUTE SINTHESI

Ŷ Low Energy, A-Class, synchronous pump EEI ≤ 0.20 (6 metres)


single speed.
Ŷ Specific for high temperature systems.
Ŷ Possibility of outdoor installation with frost protection kit
(optional).
Ŷ Designed for easy installation, commissioning and servicing.
Ŷ Post heat-exchanger in aluminum alloy.
INTERAXES AND HYDRAULIC
Ŷ Two air inlet holes (right and left side).
FITTINGS POSITIONING Ŷ Expansion vessel 8 litres.
Central heating Gas Domestic water
Ŷ Built-in thermoregulation (external sensor as option).
R F G O I
Ŷ IPX5D electrical protection.
65 120 60 55
Ŷ Condensate collector tray neutralizer kit (as option).
Ŷ Hydraulic cover connection available as option.
Ŷ Template, hydraulic connections, gas and DHW taps supplied as
standard.
Ŷ Can be matched with BeSMART Control working as WiFi
thermostat in OTBus communication, allowing exstensive TOP
advantages.

Condensing with post heat-exchanger

DIMENSIONS INPUT DHW ENERGY CLASS


CODE GAS MODEL H ×W × D PRODUCTION
(mm) (kW) (l/min. - Δt 25 °C)
INSTANTANEOUS COMBI BOILERS

MYNUTE SINTHESI
20103133 NG 780 × 400 × 336 25.00 14.3
25 C.S.I.
MYNUTE SINTHESI
20103134 NG 780 × 452 × 336 29.00 16.6
29 C.S.I.

54
Combi wall-hung boilers for high temperature systems
MYNUTE SINTHESI

Comfort accessories for smartphone and tablet *

CONDENSING
BOILERS
CODE DESCRIPTION

20111876 BeSMART WIFI CONTROL KIT (1)


20111878 BeSMART CONTROL (2)

(*) For all information about BeSMART and its wide range of accessories, please refer to the first chapter of this catalogue “SMART SYSTEMS”.
(1) Complete kit for WiFi installation.
(2) Only BeSMART thermostat.

Other accessories

CODE DESCRIPTION

Comfort accessories
20059641 ALPHA DGT WIRELESS digital room thermostat
20059639 ALPHA DGT digital room thermostat
20101748 ALPHA 7D WIRELESS 7-day digital room thermostat
20063872 ALPHA 7D 7-day digital room thermostat
20049748 Outdoor probe with connector
Hydraulic accessories
1101989 Heating taps
1101999 Heating taps with filter
20105959 High head Low Energy pump (7 metres)
20035644 Solar diverter valve
20097192 Condensate pump
20105784 Upper cover kit for 25 C.S.I.
20105786 Upper cover kit for 29 C.S.I.
20109799 Frost protection resistances
20102924 Condensate collector tray neutralizer kit

= NEW (the green rectangle identifies a new code)

55
Combi wall-hung boilers for high temperature systems
CIAO AT

Ŷ Low Energy, A-Class, synchronous pump EEI ≤ 0.20 (6 metres)


single speed.
Ŷ Specific for high temperature systems.
Ŷ Possibility of outdoor installation with frost protection kit
(optional).
Ŷ Designed for easy installation, commissioning and servicing.
Ŷ Post heat-exchanger in aluminum alloy.
INTERAXES AND HYDRAULIC
Ŷ Two air inlet holes (right and left side).
FITTINGS POSITIONING Ŷ Expansion vessel 8 litres (25 C.S.I.) and 9 litres (29 C.S.I.).
Central heating Gas Domestic water
Ŷ Built-in thermoregulation (external sensor as option).
R F G O I
Ŷ IPX5D electrical protection.
65 120 60 55
Ŷ Kit cassetto neutralizzatore raccogli condensa (optional).
Ŷ Hydraulic cover connection available as option.
Ŷ Template, hydraulic connections, gas and DHW taps available as
option.
Ŷ Can be matched with BeSMART Control working as WiFi
thermostat in OTBus communication, allowing exstensive TOP
advantages.

Condensing with post heat-exchanger

DIMENSIONS INPUT DHW ENERGY CLASS


CODE GAS MODEL H ×W × D PRODUCTION
(mm) (kW) (l/min. - Δt 25 °C)
INSTANTANEOUS COMBI BOILERS

CIAO AT
20113788 NG 780 × 400 × 336 25.00 14.3
25 C.S.I.
CIAO AT
20113789 NG 780 × 452 × 336 29.00 16.6
29 C.S.I.

= NEW (the green rectangle identifies a new code)

56
Combi wall-hung boilers for high temperature systems
CIAO AT

Comfort accessories for smartphone and tablet *

CONDENSING
BOILERS
CODE DESCRIPTION

20111876 BeSMART WIFI CONTROL KIT (1)


20111878 BeSMART CONTROL (2)

(*) For all information about BeSMART and its wide range of accessories, please refer to the first chapter of this catalogue “SMART SYSTEMS”.
(1) Complete kit for WiFi installation.
(2) Only BeSMART thermostat.

Other accessories

CODE DESCRIPTION

Comfort accessories
20059641 ALPHA DGT WIRELESS digital room thermostat
20059639 ALPHA DGT digital room thermostat
20101748 ALPHA 7D WIRELESS 7-day digital room thermostat
20063872 ALPHA 7D 7-day digital room thermostat
20049748 Outdoor probe with connector
Hydraulic accessories
1101989 Heating taps
1101999 Heating taps with filter
20035644 Solar diverter valve
20097192 Condensate pump
20105784 Upper cover kit for 25 C.S.I.
20105786 Upper cover kit for 29 C.S.I.
20109799 Frost protection resistances
20102924 Condensate collector tray neutralizer kit
20114670 Hydraulic connection kit Ciao AT

= NEW (the green rectangle identifies a new code)

57
High power wall-hung boilers
MYNUTE GREEN 50 R.S.I.

Ŷ MYNUTE GREEN 50 R.S.I. is a high power condensing boiler,


that can be configurated in different ways, according to your
needs.
Ŷ On ErP boilers: Low Energy, A-Class, synchronous pump (EEI ≤
0.23).
Ŷ The RANGE RATED certification allows to adapt the power of the boiler
to the real thermal requests of the installation.
INTERAXES AND HYDRAULIC
FITTINGS POSITIONING Ŷ Low NOx (Class 5 according to European Directive UNI EN 483) the
CH Cond Gas CH best European category in ecological terms, helping to safeguard the
R C G F environment.
48 230 107 Ŷ Condensing heat exchanger in extruded aluminium with radial design
that allows to get the most from the combustion of the gas, whether
NG or LPG.
Ŷ Compact dimensions and low weight make MYNUTE GREEN 50 R.S.I.
the ideal choice wherever you need to replace an old appliance in a
narrow space.
Ŷ User-friendly interface, providing a high number of settings to the
installer.
Ŷ Built-in thermoregulation with outdoor probe kit provided as standard.
Ŷ Built-in interface board for second pump control.
Ŷ LPG conversion kit available as an accessory.
Ŷ Can be matched with BeSMART Control working as WiFi
thermostat in OTBus communication, allowing exstensive TOP
advantages (only for stand-alone application).

Premix condensing

DIMENSIONS CH INPUT DHW ENERGY CLASS


CODE GAS MODEL H ×W × D MIN - MAX PRODUCTION
(mm) (kW) (l/min. - Δt 25 °C)
HEATING ONLY BOILERS

MYNUTE GREEN
20100121 NG 764 × 553 × 284 9.00 - 47.00 - -
50 R.S.I.

According to the European Directive ERP, the following products are not allowed
Premix condensing to be placed on the European market by the manufacturer since 01/08/2015

DIMENSIONS CH INPUT DHW


CODE GAS MODEL H ×W × D MIN - MAX PRODUCTION
(mm) (kW) (l/min. - Δt 25 °C)
HEATING ONLY BOILERS

MYNUTE GREEN
20056275 NG 764 × 553 × 284 9.00 - 47.00 -
50 R.S.I.

58
High power wall-hung boilers
MYNUTE GREEN 50 R.S.I.

Accessories

CONDENSING
BOILERS
Beretta has developed a specific line of hydraulic and safety kits and components that enable different configurations of this boiler, according to your
installation needs. Besides harmonizing perfectly with each other, MYNUTE GREEN 50 R.S.I. specific kits and components ensure maximum comfort
and saving that are supplied only by a unique specialised supplier. See the different configurations schemes in the following pages.

Comfort accessories for smartphone and tablet *

CODE DESCRIPTION

20111876 BeSMART WIFI CONTROL KIT (1)


20111878 BeSMART CONTROL (2)

(*) For all information about BeSMART and its wide range of accessories, please refer to the first chapter of this catalogue “SMART SYSTEMS”.
(1) Complete kit for WiFi installation.
(2) Only BeSMART thermostat.

CODE DESCRIPTION

Specific kits and accessories


20028475 Hydraulic header/separator kit
20028473 I.N.A.I.L. (*) hydraulic manifold
20028474 I.N.A.I.L. (*) safety kit
20028478 Air intake kit for B23 installation (**)
1220599 Socket probe for DHW tank - 3 m wire
20028476 3-ways valve kit for DHW tank
20043895 Gas-safety cut-off valve
20028472 Taps for system without I.N.A.I.L. (*) safeties
20028027 Flue adapter kit from Ø 80-80 to Ø 60/100
20028029 Flue adapter kit from Ø 80-80 to Ø 80/125
20044862 Ø 80 clapet kit in PP with built-in condensate syphon
20029862 Frost-protection kit for condensate syphon
Comfort accessories
20059641 ALPHA DGT WIRELESS digital room thermostat
20059639 ALPHA DGT digital room thermostat
20101748 ALPHA 7D WIRELESS 7-day digital room thermostat
20063872 ALPHA 7D 7-day digital room thermostat
20062614 BE09 interface for alarm remotation

(*) I.N.A.I.L. = Italian Safety Certification Institute.


I.N.A.I.L. safeties are compulsory only in Italy.
(**) Other flues configurations are possible as this boiler is homologated to work under many different installation types of the categories “B” and “C”.

59
High power wall-hung boilers
MYNUTE GREEN 50 R.S.I.
BERETTA SUGGESTED CONFIGURATIONS

Beretta indicates in the following pages a selection of the most common configurations of MYNUTE GREEN 50 R.S.I., among which you can choose the
one that best meets your installation requirements.

Configuration for central heating only

CODE DESCRIPTION Q.TY

20100121 Mynute Green 50 R.S.I. (ErP model) 1


20028472 Taps for system 1
20028475 Hydraulic header/separator kit 1
20028478 Air intake kit for B23 (*) 1
(**) Second pump kit for main CH 1
(*) Other flues configurations are possible as this boiler is homologated to work under
many different installation types of the categories “B” and “C”.
(**) For sizing advice please contact Pre-Sales Department.

Configuration with 3-ways valve kit for central heating and DHW tank

CODE DESCRIPTION Q.TY

20100121 Mynute Green 50 R.S.I. (ErP model) 1


20028472 Taps for system 1
20028475 Hydraulic header/separator kit 1
20028478 Air intake kit for B23 (*) 1
20028476 “3-ways valve kit” for DHW tank 1
1220599 Socket probe for DHW tank - 3 m wire 1
(**) Second pump kit for main CH 1
(*) Other flues configurations are possible as this boiler is homologated to work under
many different installation types of the categories “B” and “C”.
(**) For sizing advice please contact Pre-Sales Department.

60
High power wall-hung boilers
MYNUTE GREEN 50 R.S.I.
BERETTA SUGGESTED CONFIGURATIONS

CONDENSING
BOILERS
Configuration for central heating only - with I.N.A.I.L. safety kit

CODE DESCRIPTION Q.TY

20100121 Mynute Green 50 R.S.I. (ErP model) 1


20028473 I.N.A.I.L. hydraulic manifold with taps 1
20028474 I.N.A.I.L. safety kit 1
20043895 Gas-safety cut-off valve 1
20028475 Hydraulic header/separator kit 1
20028478 Air intake kit for B23 (*) 1
(**) Second pump kit for main CH 1
(*) Other flues configurations are possible as this boiler is homologated to work
under many different installation types of the categories “B” and “C”.
(**) For sizing advice please contact Pre-Sales Department.

I.N.A.I.L. = Italian Safety Certification Institute.


I.N.A.I.L. safeties are compulsory only in Italy.
Beretta recommends safety devices also in countries where they are not compulsory.

Configuration with 3-ways valve kit for central heating and DHW tank - with I.N.A.I.L. safety kit

CODE DESCRIPTION Q.TY

20100121 Mynute Green 50 R.S.I. (ErP model) 1


20028473 I.N.A.I.L. hydraulic manifold with taps 1
20028474 I.N.A.I.L. safety kit 1
20043895 Gas-safety cut-off valve 1
20028475 Hydraulic header/separator kit 1
20028478 Air intake kit for B23 (*) 1
20028476 “3-ways valve kit” for DHW tank 1
1220599 Socket probe for DHW tank - 3 m wire 1
(**) Second pump kit for main CH 1
(*) Other flues configurations are possible as this boiler is homologated to work
under many different installation types of the categories “B” and “C”.
(**) For sizing advice please contact Pre-Sales Department.

I.N.A.I.L. = Italian Safety Certification Institute.


I.N.A.I.L. safeties are compulsory only in Italy.
Beretta recommends safety devices also in countries where they are not compulsory.

61
HYBRID combi floor-standing boilers with built-in DHW cylinder, for solar thermal
TOWER GREEN HE HYBRID S
Ŷ TOWER GREEN HE HYBRID S + solar collectors + heat pump
form a system in energy class A+.
SYSTEM Ŷ Management of multiple energy sources: condensing boiler,
solar thermal, hydronic heat pump for heating and cooling.
Ŷ 10 : 1 modulation ratio, the highest range of modulation.
BERETTA HIGH-EFFICIENCY
Ŷ Low Energy, A-Class, auto-modulating system pumps (EEI ≤ 0.20).
Ŷ Suitable for 3 internal zones management.
Ŷ Class 5 according to European Directive UNI EN 483.
Ŷ Designed for connection with solar collectors and hydronic heat pump.
Ŷ Interface with wide display for complete management, that can be
removed from the boiler and located inside the house as a control
panel.
Ŷ Built-in hydraulic separator with one direct zone with low energy pump.
Ŷ 200 lt. built-in DHW double-coil cylinder.
Ŷ 8 lt. built-in DHW expansion vessel.
Ŷ 18 lt. built-in solar circuit expansion vessel.
Ŷ Built-in thermoregulation with external probe supplied as standard.
Ŷ Display languages: ITALIAN and ENGLISH.
Ŷ Can be matched with BeSMART Control working as WiFi
thermostat (no OTBus communication).

Premix condensing

DIMENSIONS INPUT DHW CYLINDER ENERGY CLASS


CODE GAS MODEL H ×W × D MIN - MAX CAPACITY
(mm) (kW) (litres)
COMBI BOILERS WITH BUILT-IN DHW TANK
TOWER GREEN HE 200
20092677* NG 1900 × 600 × 775 3.50 - 34.60
HYBRID S 35/200 B.S.I. double coil
* Destination countries must be checked before placing the order.
TOWER GREEN HE HYBRID S code does not include solar collector and heat pump, to be chosen according to your needs among the codes proposed in
the following tables.

Comfort accessories for smartphone and tablet *

CODE DESCRIPTION CODE DESCRIPTION


20111876 BeSMART WIFI CONTROL KIT (1) 20111878 BeSMART CONTROL (2)
(*) For all information about BeSMART and its wide range of accessories, please refer to the first chapter of this catalogue “SMART SYSTEMS”.
(1) Complete kit for WiFi installation.
(2) Only BeSMART thermostat.

Other accessories

CODE DESCRIPTION CODE DESCRIPTION


Comfort accessories Hydraulic accessories
20059641 ALPHA DGT WIRELESS digital room thermostat 20097192 Condensate pump
20059639 ALPHA DGT digital room thermostat 20084749 DHW recirculation kit with pump
20101748 ALPHA 7D WIRELESS 7-day digital room thermostat 20084750 Check valves kit fot CH and DHW
20063872 ALPHA 7D 7-day digital room thermostat 20104496 25 litres multi-energy tank kit
20093833 Additional direct zone kit Special accessories
20093831 Additional motorized mixed zone kit 20083900 Interface kit for remote control
20106843 Remote control panel 20085223 Limit thermostat for low temperature installations

= NEW (the green rectangle identifies a new code) 20106844 Template installation kit

62
HYBRID combi floor-standing boilers with built-in DHW cylinder, for solar thermal
TOWER GREEN HE HYBRID S

Heat pump HYDRONIC UNIT to be matched with TOWER GREEN HE HYBRID S

CONDENSING
BOILERS
DIMENSIONS RATED CAPACITY ENERGY CLASS
CODE MODEL H ×W × D HEAT. (1) - COOL. (2)
(mm) (kW) 55° 35°

20103221 HYDRONIC UNIT LE 4 B 821 × 908 × 326 4.07 - 4.93

20103222 HYDRONIC UNIT LE 6 B 821 × 908 × 326 5.76 - 7.04

20103225 HYDRONIC UNIT LE 8 B 821 × 908 × 326 7.146 - 7.84

20103226 HYDRONIC UNIT LE 12 B 1363 × 908 × 326 11.86 - 13.54

(1) outside air d.b. + 7 °C, water 30/35 °C


(2) outside air d.b. + 35 °C, water 23/18 °C

Solar collectors to be matched with TOWER GREEN HE HYBRID S

CODE DESCRIPTION MODEL

20050314 TRAY COLLECTOR 2,5 m2 SCF-V25

20095375 FLAT COLLECTOR 2,5 m2 SCF-25B

20095379 FLAT COLLECTOR 2 m2 SCF-20B

20050330 INSET COLLECTOR 2,5 m2 SCI-25N

20099915 HORIZONTAL COLLECTOR 2,5 m2 SCO-25B

20026324 EVACUATED TUBE COLLECTOR 2,5 m2 SCV-25

63
HYBRID combi floor-standing boilers with built-in DHW cylinder, for solar thermal
TOWER GREEN HE HYBRID S

System diagram with TOWER GREEN HE HYBRID S, solar collector and heat pump

1
4

10
3 7
DHW
8
7

DCW

This scheme has only an indication purpose: cooling is also possible by using FAN COILS

1 Tray solar collectors SCF-V25


2 Condensing floor-standing boiler TOWER GREEN HE HYBRID S 35/200 BSI
3 DHW
4 Direct zone/high temperature
5 Mixed zone n°1/low temperature
6 Mixed zone n°2/low temperature
7 Heat pump HYDRONIC UNIT LE B 4, 6, 8, 12 kW
8 DHW recirculation kit (optional accessory that can be installed in the boiler consinsting of a pump with a timer regulator)
9 8 litres built-in DHW expansion vessel
10 18 litres built-in solar circuit expansion vessel

64
HYBRID combi floor-standing boilers with built-in DHW tank
TOWER GREEN HE HYBRID
Ŷ TOWER GREEN HE HYBRID + heat pump form a system in energy
class A+.
SYSTEM Ŷ Management of multiple energy sources: condensing boiler and

CONDENSING
hydronic heat pump for heating and cooling.

BOILERS
Ŷ 10 : 1 modulation ratio, the highest range of modulation.
BERETTA HIGH-EFFICIENCY Ŷ Low Energy, A-Class, auto-modulating system pumps (EEI ≤ 0.20).
Ŷ Suitable for 3 internal zones management.
Ŷ Class 5 according to European Directive UNI EN 483.
Ŷ Designed for connection with hydronic heat pump.
Ŷ Interface with wide display for complete management, that can be
removed from the boiler and located inside the house as a control panel.
Ŷ Built-in hydraulic separator with one direct zone with low energy pump.
Ŷ 200 lt. built-in DHW double-coil cylinder.
Ŷ 8 lt. built-in DHW expansion vessel
Ŷ 18 lt. built-in solar circuit expansion vessel.
Ŷ Built-in thermoregulation with external probe supplied as standard.
Ŷ Display languages: ITALIAN and ENGLISH.
Ŷ Can be matched with BeSMART Control working as WiFi
thermostat (no OTBus communication).

Premix condensing

DIMENSIONS INPUT DHW CYLINDER ENERGY CLASS


CODE GAS MODEL H ×W × D MIN - MAX CAPACITY
(mm) (kW) (litres)
COMBI BOILERS WITH BUILT-IN DHW TANK

TOWER GREEN HE 200


20104212* NG 1900 × 600 × 775 3.50 - 34.60
HYBRID 35/200 B.S.I. double coil
* Destination countries must be checked before placing the order.
TOWER GREEN HE HYBRID code does not include heat pump, to be chosen according to your needs among the codes proposed in the following tables.

Comfort accessories for smartphone and tablet *

CODE DESCRIPTION CODE DESCRIPTION


20111876 BeSMART WIFI CONTROL KIT (1) 20111878 BeSMART CONTROL (2)
(*) For all information about BeSMART and its wide range of accessories, please refer to the first chapter of this catalogue “SMART SYSTEMS”.
(1) Complete kit for WiFi installation.
(2) Only BeSMART thermostat.

Other accessories

CODE DESCRIPTION CODE DESCRIPTION


Comfort accessories Hydraulic accessories
20059641 ALPHA DGT WIRELESS digital room thermostat 20097192 Condensate pump
20059639 ALPHA DGT digital room thermostat 20084749 DHW recirculation kit with pump
20101748 ALPHA 7D WIRELESS 7-day digital room thermostat 20084750 Check valves kit fot CH and DHW
20063872 ALPHA 7D 7-day digital room thermostat 20104496 25 litres multi-energy tank kit
20093833 Additional direct zone kit Special accessories
20093831 Additional motorized mixed zone kit 20083900 Interface kit for remote control
20106843 Remote control panel 20085223 Limit thermostat for low temperature installations

= NEW (the green rectangle identifies a new code) 20106844 Template installation kit
65
HYBRID combi floor-standing boilers with built-in DHW tank
TOWER GREEN HE HYBRID

Heat pump HYDRONIC UNIT to be matched with TOWER GREEN HE HYBRID

DIMENSIONS RATED CAPACITY ENERGY CLASS


CODE MODEL H ×W × D HEAT. (1) - COOL. (2)
(mm) (kW) 55° 35°

20103221 HYDRONIC UNIT LE 4 B 821 × 908 × 326 4.07 - 4.93

20103222 HYDRONIC UNIT LE 6 B 821 × 908 × 326 5.76 - 7.04

20103225 HYDRONIC UNIT LE 8 B 821 × 908 × 326 7.146 - 7.84

20103226 HYDRONIC UNIT LE 12 B 1363 × 908 × 326 11.86 - 13.54

(1) outside air d.b. + 7 °C, water 30/35 °C


(2) outside air d.b. + 35 °C, water 23/18 °C

66
HYBRID combi floor-standing boilers with built-in DHW tank
TOWER GREEN HE HYBRID

System diagram with TOWER GREEN HE HYBRID and heat pump

CONDENSING
BOILERS
3

2 6
DHW
7

DCW

This scheme has only an indication purpose: cooling is also possible by using FAN COILS

1 Condensing floor-standing boiler TOWER GREEN HE HYBRID 35/200 BSI


2 DHW
3 Direct zone/high temperature
4 Mixed zone n°1/low temperature
5 Mixed zone n°2/low temperature
6 Heat pump HYDRONIC UNIT LE B 4, 6, 8, 12 kW
7 DHW recirculation kit (optional accessory that can be installed in the boiler consinsting of a pump with a timer regulator)
8 8 litres built-in DHW expansion vessel

67
Combi floor-standing boilers with built-in DHW cylinder, for solar thermal
TOWER GREEN HE S
Ŷ TOWER GREEN HE S + solar collectors form a system in energy
class A+ in DHW.
Ŷ Low Energy, A-Class, auto-modulating system pumps (EEI ≤ 0.23).
XL Ŷ 10 : 1 modulation ratio, the highest range of modulation.
SYSTEM Ŷ Possibility to manage up to 3 heating zones.
Ŷ Class 5 according to European Directive UNI EN 483.
Ŷ Condensing heat exchanger.
Ŷ Suitable for connection with solar thermal collectors.
Ŷ 200 lt. built-in DHW double-coil cylinder.
Ŷ Interface with wide display for complete management, that can be
BERETTA HIGH-EFFICIENCY removed from the boiler and located inside the house as a control panel.
Ŷ Pump for solar circuit as standard.
Ŷ Flow-meter on solar circuit as standard.
Ŷ 18 lt. expansion vessel for solar circuit as standard.
Ŷ Mixing valve as standard.
Ŷ 8 lt. expansion vessel for DHW circuit as standard.
Ŷ Built-in thermoregulation with external probe supplied as standard.
Ŷ Built-in hydraulic separator with one direct zone with low energy pump.
Ŷ Display languages: ITALIAN and ENGLISH.
Ŷ Can be matched with BeSMART Control working as WiFi
thermostat (no OTBus communication).

Premix condensing

DIMENSIONS INPUT DHW CYLINDER ENERGY CLASS


CODE GAS MODEL H ×W × D MIN - MAX CAPACITY
(mm) (kW) (litres)
COMBI BOILERS WITH BUILT-IN DHW TANK
TOWER GREEN HE S 200
20071816* NG 1900 × 600 × 775 3.50 - 34.60
35/200 B.S.I. double coil
* Destination countries must be checked before placing the order.

Comfort accessories for smartphone and tablet *

CODE DESCRIPTION CODE DESCRIPTION


20111876 BeSMART WIFI CONTROL KIT (1) 20111878 BeSMART CONTROL (2)
(*) For all information about BeSMART and its wide range of accessories, please refer to the first chapter of this catalogue “SMART SYSTEMS”.
(1) Complete kit for WiFi installation.
(2) Only BeSMART thermostat.

Other accessories
CODE DESCRIPTION CODE DESCRIPTION
Specific accessories Hydraulic accessories
20083258 Additional direct zone 20097192 Condensate pump
20080038 Additional motorized mixed zone kit Comfort accessories
20083259 Remote control panel 20059641 ALPHA DGT WIRELESS digital room thermostat
20083900 Interface kit for remote control 20059639 ALPHA DGT digital room thermostat
20084749 DHW recirculation kit with pump 20101748 ALPHA 7D WIRELESS 7-day digital room thermostat
20084750 Check valves kit for CH and DHW 20063872 ALPHA 7D 7-day digital room thermostat
20084751 Template kit for installation Special accessories
= NEW (the green rectangle identifies a new code) 20085223 Limit thermostat for low temperature installations
68
Combi floor-standing boilers with built-in DHW tank
TOWER GREEN HE

Ŷ Low Energy, A-Class, auto-modulating system pumps (EEI ≤ 0.23).


Ŷ 10 : 1 modulation ratio, the highest range of modulation.
Ŷ Suitable for 3 internal zones management.

CONDENSING
BOILERS
Ŷ Class 5 according to European Directive UNI EN 483.
Ŷ Condensing heat exchanger.
Ŷ Interface with wide display for complete management, that can be
removed from the boiler and located inside the house as a control
panel.
Ŷ Built-in hydraulic separator with one direct zone with low energy pump.
Ŷ 120 lt. built-in DHW tank.
BERETTA HIGH-EFFICIENCY
Ŷ 6 lt. built-in DHW expansion vessel.
Ŷ Built-in thermoregulation with external probe supplied as standard.
Ŷ Management with direct sliding temperature or with motorized mixing
valves on the system zones.
Ŷ Display languages: ITALIAN and ENGLISH.
Ŷ Can be matched with BeSMART Control working as WiFi
thermostat (no OTBus communication).

Premix condensing

DIMENSIONS INPUT DHW TANK ENERGY CLASS


CODE GAS MODEL H ×W × D MIN - MAX CAPACITY
(mm) (kW) (litres)
COMBI BOILERS WITH BUILT-IN DHW TANK
TOWER GREEN HE
20071817* NG 1536 × 600 × 775 3.50 - 34.60 120
35/120 B.S.I.
* Destination countries must be checked before placing the order.

Comfort accessories for smartphone and tablet *

CODE DESCRIPTION CODE DESCRIPTION


20111876 BeSMART WIFI CONTROL KIT (1) 20111878 BeSMART CONTROL (2)
(*) For all information about BeSMART and its wide range of accessories, please refer to the first chapter of this catalogue “SMART SYSTEMS”.
(1) Complete kit for WiFi installation.
(2) Only BeSMART thermostat.

Other accessories
CODE DESCRIPTION CODE DESCRIPTION
Specific accessories Hydraulic accessories
20083258 Additional direct zone 20097192 Condensate pump
20080038 Additional motorized mixed zone kit Comfort accessories
20083259 Remote control panel 20059641 ALPHA DGT WIRELESS digital room thermostat
20083900 Interface kit for remote control 20059639 ALPHA DGT digital room thermostat
20084991 DHW recirculation kit with pump 20101748 ALPHA 7D WIRELESS 7-day digital room thermostat
20084750 Check valves kit for CH and DHW 20063872 ALPHA 7D 7-day digital room thermostat
20084990 Template kit for installation Special accessories
= NEW (the green rectangle identifies a new code) 20085223 Limit thermostat for low temperature installations

69
Combi floor-standing boilers with built-in DHW tank
TOWER GREEN HE COMPACT

Ŷ Low Energy, A-Class, auto-modulating system pumps (EEI ≤ 0.23).


Ŷ 10 : 1 modulation ratio, the highest range of modulation.
Ŷ 60 lt. built-in DHW tank.
Ŷ Low NOx (Class 5 according to European Directive UNI EN 483).
Ŷ Condensing heat exchanger.
Ŷ 2 lt. expansion vessel for DHW circuit as standard.
Ŷ Built-in hydraulic separator with one direct zone with low energy pump.
Ŷ Built-in thermoregulation with external probe supplied as standard.
Ŷ Interface with wide display for complete management, that can be
BERETTA HIGH-EFFICIENCY removed from the boiler and located inside the house as a control panel.
Ŷ Display languages: ITALIAN and ENGLISH.
Ŷ Can be matched with BeSMART Control working as WiFi
thermostat (no OTBus communication).

Premix condensing

DIMENSIONS INPUT DHW TANK ENERGY CLASS


CODE GAS MODEL H ×W × D MIN - MAX CAPACITY
(mm) (kW) (litres)
COMBI BOILERS WITH BUILT-IN DHW TANK

TOWER GREEN HE
20084705* NG 850 × 700 × 610 3.50 - 34.60 60
35/60 B.S.I.

* Destination countries must be checked before placing the order.

Comfort accessories for smartphone and tablet *

CODE DESCRIPTION CODE DESCRIPTION

20111876 BeSMART WIFI CONTROL KIT (1) 20111878 BeSMART CONTROL (2)
(*) For all information about BeSMART and its wide range of accessories, please refer to the first chapter of this catalogue “SMART SYSTEMS”.
(1) Complete kit for WiFi installation.
(2) Only BeSMART thermostat.

Accessories

CODE DESCRIPTION CODE DESCRIPTION


20083259 Remote control panel Comfort accessories
20083900 Interface kit for remote control 20059641 ALPHA DGT WIRELESS digital room thermostat
20084750 Check valves kit for CH and DHW 20059639 ALPHA DGT digital room thermostat
20092037 Template kit for installation 20101748 ALPHA 7D WIRELESS 7-day digital room thermostat
Hydraulic accessories 20063872 ALPHA 7D 7-day digital room thermostat
20097192 Condensate pump Special accessories
= NEW (the green rectangle identifies a new code) 20085223 Limit thermostat for low temperature installations

70
‘Heating-only’ floor-standing boilers
TOWER GREEN HE COMPACT R.S.I.

Ŷ Low Energy, A-Class, auto-modulating system pumps (EEI ≤ 0.23).

CONDENSING
Ŷ 10 : 1 modulation ratio, the highest range of modulation.

BOILERS
Ŷ Low NOx (Class 5 according to European Directive UNI EN 483).
Ŷ Condensing heat exchanger.
Ŷ Built-in hydraulic separator with one direct zone with low energy pump.
Ŷ Possibility of managing up to 3 internal zones.
Ŷ 3-ways valve to manage an optional external DHW tank.
Ŷ Built-in thermoregulation with external probe supplied as standard.
Ŷ Interface with wide display for complete management, that can be
BERETTA HIGH-EFFICIENCY removed from the boiler and located inside the house as a control
panel.
Ŷ Display languages: ITALIAN and ENGLISH.
Ŷ Can be matched with BeSMART Control working as WiFi
thermostat (no OTBus communication).

Premix condensing

DIMENSIONS INPUT DHW TANK ENERGY CLASS


CODE GAS MODEL H ×W × D MIN - MAX CAPACITY
(mm) (kW) (litres)

HEATING ONLY BOILERS

TOWER GREEN HE
20093830* NG 850 × 700 × 610 3.50 - 34.60 - -
35 R.S.I.
* Destination countries must be checked before placing the order.

Comfort accessories for smartphone and tablet *

CODE DESCRIPTION CODE DESCRIPTION

20111876 BeSMART WIFI CONTROL KIT (1) 20111878 BeSMART CONTROL (2)
(*) For all information about BeSMART and its wide range of accessories, please refer to the first chapter of this catalogue “SMART SYSTEMS”.
(1) Complete kit for WiFi installation.
(2) Only BeSMART thermostat.

Accessories

CODE DESCRIPTION CODE DESCRIPTION


20083258 Additional direct zone Comfort accessories
20080038 Additional motorized mixed zone kit 20059641 ALPHA DGT WIRELESS digital room thermostat
20083259 Remote control panel 20059639 ALPHA DGT digital room thermostat
20083900 Interface kit for remote control 20101748 ALPHA 7D WIRELESS 7-day digital room thermostat
20092037 Template kit for installation 20063872 ALPHA 7D 7-day digital room thermostat
Hydraulic accessories Special accessories
1220599 Socket probe for DHW tank - 3 m wire 20085223 Limit thermostat for low temperature installations
20097192 Condensate pump = NEW (the green rectangle identifies a new code)

71
Additional zones configurations
TOWER GREEN

Additional zones configurations for TOWER GREEN HE HYBRID S - TOWER GREEN HE HYBRID
ADDITIONAL DIRECT ZONE ADDITIONAL MIXED ZONE
ZONES
(CODE 20093833) (CODE 200938318)
1 direct zone + 1 mixed zone - no 1
1 direct zone + 2 mixed zones - no 2
2 direct zones no 1 -
3 direct zones no 2 -
2 direct zones + 1 mixed zone no 1 no 1

Additional zones configurations for TOWER GREEN HE - HE S - HE COMPACT R.S.I.


ADDITIONAL DIRECT ZONE ADDITIONAL MIXED ZONE
ZONES
(CODE 20083258) (CODE 20080038)

1 direct zone + 1 mixed zone - no 1


1 direct zone + 2 mixed zones - no 2
2 direct zones no 1 -
3 direct zones no 2 -
2 direct zones + 1 mixed zone no 1 no 1

72
STANDARD-EFFICIENCY
BOILERS
STANDARD-EFFICIENCY
BOILERS

73
Wall-hung boilers
PRODUCT MATRIX OF BERETTA STANDARD-EFFICIENCY BOILERS

PRODUCT COMBI MODELS


ENERGY CLASS room-sealed conventional flue

_
C B XL
24 (NG)
EXCLUSIVE
26 (NG) 28 (NG)
non ErP compliant (*) 30 (NG)
35 (NG)

24 (NG - LPG)
C B XL 28 (NG)
with INSTANTANEOUS DHW PRODUCTION

MYNUTE S
24 (NG - LPG) 24 (NG)
non ErP compliant (*) 28 (NG - LPG)
35 (NG) 28 (NG)

20 (NG) _
CIAO S non ErP compliant (*)
24 (NG - LPG)

C B XL

QUADRA II (1) 24 (NG)


24 (NG)
non ErP compliant (*)
28 (NG)

C B XL
24 (NG)
CIAO 20 (NG) 28 (NG)
non ErP compliant (*) 24 (NG - LPG)
28 (NG - LPG)
with BUILT-IN
DHW TANK

C B XL

MYNUTE BOILER 28 (NG)


24 (NG)
non ErP compliant (*)
28 (NG)

(*) According to the European Directive ERP, these products are not allowed to be placed on the European market by the manufacturer since 01/08/2015
(1) With new DIN connections to enable an easy installation in buildings with the same configuration.

74
‘HEATING-ONLY’ MODELS DHW BeSMART WIFI
room-sealed conventional flue PRODUCTION

STANDARD-EFFICIENCY
_ _

BOILERS
via DHW heat-exchanger compatible
in stainless steel (as option)
30 (NG)
28 (NG)
35 (NG)

_ via DHW heat-exchanger compatible


in stainless steel (as option)
28 (NG)
35 (NG)

_ via DHW heat-exchanger compatible


24 (NG)
in stainless steel (as option)

_ _ via DHW heat-exchanger compatible


in stainless steel (as option)

_ _ via bithermic heat-exchanger compatible


in copper (as option)

via DHW tank


_ _ compatible
(45/60 litres capacity)
(as option)
in stainless steel

75
Combi and ‘heating only’ wall-hung boilers
EXCLUSIVE

Ŷ On ErP boilers: Low Energy, synchronous pump EEI ≤ 0.20.


Ŷ Air/gas electronic combustion control = constant efficiency
(on room-sealed models).
Ŷ Automatic room-temperature adjustment system (S.A.R.A. Booster).
Ŷ User-friendly and intuitive digital back-lit display.
Ŷ Easy filling system directly from the panel.
Ŷ “Comfort” functions.
INTERAXES AND HYDRAULIC Ŷ IPX5D electrical protection.
FITTINGS POSITIONING Ŷ Built-in thermoregulation (external probe as option).
Central heating Gas Domestic water
Ŷ Hydraulic connections cover supplied as standard.
R F G O I
Ŷ Modulating fan (only on room-sealed models).
65 120 60 55
Ŷ Hydraulic connections, gas and DHW taps supplied as standard.
Ŷ Can be matched with BeSMART Control working as WiFi
thermostat in OTBus communication, allowing exstensive TOP
advantages.

Conventional flue
DIMENSIONS DHW ENERGY CLASS
OUTPUT
CODE GAS MODEL H ×W × D PRODUCTION
(kW)
(mm) (l/min. - Δt 25 °C)
INSTANTANEOUS COMBI BOILERS

20095668 NG EXCLUSIVE 24 C.A.I. 805 × 400 × 332 24.00 13,7

20095669 NG EXCLUSIVE 28 C.A.I. 805 × 450 × 332 28.00 16,5

According to the European Directive ERP, the following products are not allowed
Conventional flue to be placed on the European market by the manufacturer since 01/08/2015

DIMENSIONS DHW
OUTPUT
CODE GAS MODEL H ×W × D PRODUCTION
(kW)
(mm) (l/min. - Δt 25 °C)
INSTANTANEOUS COMBI BOILERS

1150683 NG EXCLUSIVE 24 C.A.I. 805 × 400 × 332 24.00 13,7

1150693 NG EXCLUSIVE 28 C.A.I. 805 × 450 × 332 28.00 16,5

HEATING ONLY BOILERS*

1150703 NG EXCLUSIVE 28 R.A.I. 805 × 450 × 332 28.00 -


* The “heating only” models are supplied with a three-ways valve. Filling tap not available.

76
Combi and ‘heating only’ wall-hung boilers
EXCLUSIVE

According to the European Directive ERP, the following products are not allowed
Room-sealed (modulating air/gas) to be placed on the European market by the manufacturer since 01/08/2015

DIMENSIONS DHW
OUTPUT
CODE GAS MODEL H ×W × D PRODUCTION
(kW)
(mm) (l/min. - Δt 25 °C)
INSTANTANEOUS COMBI BOILERS

STANDARD-EFFICIENCY
1150343 NG EXCLUSIVE MIX 26 C.S.I. 805 × 400 × 332 26.00 15,0

BOILERS
1150673 NG EXCLUSIVE MIX 30 C.S.I. 805 × 450 × 332 30.00 17,4

1150383 NG EXCLUSIVE MIX 35 C.S.I. 805 × 500 × 332 35.00 20,2

HEATING ONLY BOILERS*

1150353 NG EXCLUSIVE MIX 30 R.S.I. 805 × 450 × 332 30.00 -

20029161 NG EXCLUSIVE MIX 35 R.S.I. 805 × 500 × 332 35.00 -

* The ‘heating only’ models are supplied with a three-ways valve. Filling tap not available.

Comfort accessories for smartphone and tablet *

CODE DESCRIPTION CODE DESCRIPTION

20111876 BeSMART WIFI CONTROL KIT (1) 20111878 BeSMART CONTROL (2)
(*) For all information about BeSMART and its wide range of accessories, please refer to the first chapter of this catalogue “SMART SYSTEMS”.
(1) Complete kit for WiFi installation.
(2) Only BeSMART thermostat.

= NEW (the green rectangle identifies a new code)

Other accessories

CODE DESCRIPTION CODE DESCRIPTION

Comfort accessories 1101999 Heating taps with filter (for combi models)
20059641 ALPHA DGT WIRELESS digital room thermostat Socket probe for DHW tank - 3m wire
1220599
(for R.A.I. and R.S.I. models)
20059639 ALPHA DGT digital room thermostat Solar diverter valve (including flexible
20025113
20101748 ALPHA 7D WIRELESS 7-day digital room thermostat stainless steel connection pipes)
High head pump (6 metres ) -
20063872 ALPHA 7D 7-day digital room thermostat 1101979
(models C.A.I. and 26/30 C.S.I.)
1221179 OTBus interface board 20105959 High head Low Energy pump (7 metres) - for ErP boilers
20049748 Outdoor probe with connector Special accessories
Hydraulic accessories 20071580 Dummy Exclusive MIX for POS
1101989 Heating taps

77
Combi and ‘heating only’ wall-hung boilers
MYNUTE S

Ŷ On ErP boilers: Low Energy, synchronous pump EEI ≤ 0.20.


Ŷ Primary heat exchanger in copper.
Ŷ DHW plate heat exchanger in stainless steel.
Ŷ Two air inlet holes (right and left side).
Ŷ Expansion vessel 9 litres.
Ŷ Intuitive and easy-to-use control panel with backlit digital display.
INTERAXES AND HYDRAULIC
FITTINGS POSITIONING
Ŷ Built-in thermoregulation (external temperature probe as option).
Central heating Gas Domestic water Ŷ IPX5D electrical protection.
R F G O I Ŷ Lower cover available as option (for 24 C.S.I., 28 C.S.I., 28 R.S.I.
65 120 60 55 models).
Ŷ Hydraulic connections, gas and DHW taps available as option.
Ŷ Can be matched with BeSMART Control working as WiFi
thermostat in OTBus communication, allowing exstensive TOP
advantages.

Conventional flue

DIMENSIONS DHW ENERGY CLASS


OUTPUT
CODE GAS MODEL H ×W × D PRODUCTION
(kW)
(mm) (l/min. - Δt 25 °C)
INSTANTANEOUS COMBI BOILERS

20095667 NG MYNUTE S 24 C.A.I. E 740 × 400 × 336 24.00 13,9

20102088 LPG MYNUTE S 24 C.A.I. E 740 × 400 × 336 24.00 13,9

20095661 NG MYNUTE S 28 C.A.I. E 740 × 452 × 336 28.00 16,4

According to the European Directive ERP, the following products are not allowed
Conventional flue to be placed on the European market by the manufacturer since 01/08/2015

DIMENSIONS DHW
OUTPUT
CODE GAS MODEL H ×W × D PRODUCTION
(kW)
(mm) (l/min. - Δt 25 °C)
INSTANTANEOUS COMBI BOILERS

20074588 NG MYNUTE S 24 C.A.I. E 740 × 400 × 336 24.00 13,9

20069390 NG MYNUTE S 28 C.A.I. E 740 × 452 × 336 28.00 16,4

According to the European Directive ERP, the following products are not allowed
Room-sealed to be placed on the European market by the manufacturer since 01/08/2015

DIMENSIONS DHW
OUTPUT
CODE GAS MODEL H ×W × D PRODUCTION
(kW)
(mm) (l/min. - Δt 25 °C)
INSTANTANEOUS COMBI BOILERS

20069385 NG MYNUTE S 24 C.S.I. 740 × 400 × 336 24.00 13,9

20069386 LPG MYNUTE S 24 C.S.I. 740 × 400 × 336 24.00 13,9

78
Combi and ‘heating only’ wall-hung boilers
MYNUTE S

According to the European Directive ERP, the following products are not allowed
Room-sealed to be placed on the European market by the manufacturer since 01/08/2015

DIMENSIONS DHW
OUTPUT
CODE GAS MODEL H ×W × D PRODUCTION
(kW)
(mm) (l/min. - Δt 25 °C)
INSTANTANEOUS COMBI BOILERS

STANDARD-EFFICIENCY
20069387 NG MYNUTE S 28 C.S.I. 740 × 400 × 336 28.00 16,0

BOILERS
20069389 LPG MYNUTE S 28 C.S.I. 740 × 400 × 336 28.00 16,0

20069392 NG MYNUTE S 35 C.S.I. 780 × 505 × 336 35.00 16,0

HEATING ONLY BOILERS*

20069391 NG MYNUTE S 28 R.S.I. 740 × 400 × 336 28.00 -

20069395 NG MYNUTE S 35 R.S.I. 780 × 505 × 336 35.00 -


* The “heating only” models are supplied with a three-ways valve. Filling tap not available.

Comfort accessories for smartphone and tablet *

CODE DESCRIPTION CODE DESCRIPTION

20111876 BeSMART WIFI CONTROL KIT (1) 20111878 BeSMART CONTROL (2)
(*) For all information about BeSMART and its wide range of accessories, please refer to the first chapter of this catalogue “SMART SYSTEMS”.
(1) Complete kit for WiFi installation.
(2) Only BeSMART thermostat.

= NEW (the green rectangle identifies a new code)

Other accessories

CODE DESCRIPTION CODE DESCRIPTION

Comfort accessories Socket probe for DHW tank -


1220599
3 m wire (for R.S.I. models)
20059641 ALPHA DGT WIRELESS digital room thermostat Solar diverter valve (including flexible
20025113
20059639 ALPHA DGT digital room thermostat stainless steel connection pipes)
Lower cover (only for 24 C.S.I.,
20101748 ALPHA 7D WIRELESS 7-day digital room thermostat 20051629
28 C.S.I., 28 R.S.I. models)
20063872 ALPHA 7D 7-day digital room thermostat 20008794 Kit hydraulic connections (for welding)
20049748 Outdoor probe with connector 20051979 Kit hydraulic connections (with brass nipples)
Hydraulic accessories 1101979 High head pump (6 metres) - for non-ErP boilers
1101989 Heating taps 20105959 High head Low Energy pump (7 metres) - for ErP boilers
1101999 Heating taps with filter

79
Combi and ‘heating only’ wall-hung boilers
CIAO S

Ŷ Primary heat exchanger in copper.


Ŷ DHW plate heat exchanger in stainless steel.
Ŷ Efficiency ★★★ according to European Directive EEC 92/42.
Ŷ Two air inlet holes (right and left side).
Ŷ Expansion vessel 8 litres.
Ŷ 3-speed circulator 5 metres (4 metres single-speed on 20 kW version).
Ŷ Intuitive and easy-to-use control panel with backlit digital display.
INTERAXES AND HYDRAULIC
FITTINGS POSITIONING
Ŷ Built-in thermoregulation (external temperature probe as option).
Central heating Gas Domestic water Ŷ IPX5D electrical protection.
R F G O I Ŷ Frost protection kit till -10 °C available as option.
65 120 60 55 Ŷ Upper and lower cover available as option.
Ŷ Hydraulic connections, gas and DHW taps available as option.
Ŷ Can be matched with BeSMART Control working as WiFi
thermostat in OTBus communication, allowing exstensive TOP
advantages.

According to the European Directive ERP, the following products are not allowed
Room-sealed to be placed on the European market by the manufacturer since 01/08/2015

DIMENSIONS DHW
OUTPUT
CODE GAS MODEL H ×W × D PRODUCTION
(kW)
(mm) (l/min. - Δt 25 °C)
INSTANTANEOUS COMBI BOILERS

20068208 NG CIAO S 20 C.S.I. 715 × 405 × 248 20.00 11,8

20068204 NG CIAO S 24 C.S.I. 715 × 405 × 248 24.00 13,7

20068228 LPG CIAO S 24 C.S.I. 715 × 405 × 248 24.00 13,7

HEATING ONLY BOILERS*

20068207 NG CIAO S 24 R.S.I. 715 × 405 × 248 24.00 -

* The “heating only” models are supplied with a three-ways valve. Filling tap not available.

80
Combi and ‘heating only’ wall-hung boilers
CIAO S

Comfort accessories for smartphone and tablet *

CODE DESCRIPTION

20111876 BeSMART WIFI CONTROL KIT (1)


20111878 BeSMART CONTROL (2)

STANDARD-EFFICIENCY
(*) For all information about BeSMART and its wide range of accessories, please refer to the first chapter of this catalogue “SMART SYSTEMS”.

BOILERS
(1) Complete kit for WiFi installation.
(2) Only BeSMART thermostat.

= NEW (the green rectangle identifies a new code)

Other accessories

CODE DESCRIPTION

Comfort accessories
20059641 ALPHA DGT WIRELESS digital room thermostat
20059639 ALPHA DGT digital room thermostat
20101748 ALPHA 7D WIRELESS 7-day digital room thermostat
20063872 ALPHA 7D 7-day digital room thermostat
20049748 Outdoor probe with connector
Hydraulic accessories
1101989 Heating taps
1101999 Heating taps with filter
20008794 Kit hydraulic connections (for welding)
20008795 Kit hydraulic connections (with brass nipples)
20025113 Solar diverter valve (including flexible stainless steel connection pipes)
1101979 High head pump (6 metres)
1220599 Socket probe for DHW tank - 3m wire (only R.S.I. models)
Special accessories
20012594 Lower cover
20012595 Upper cover
Frost protection resistances kit
20017044
till -10°C (C.S.I. models)**
(**) Together with the installation of the frost protection resistances kit (code 20017044), it is necessary to install the lower cover (code 20012594).

81
Combi wall-hung boilers
QUADRA II

Ŷ On ErP boilers: Low Energy, synchronous pump EEI ≤ 0.20.


Ŷ Primary heat exchanger in copper.
Ŷ DHW plate heat exchanger in stainless steel.
Ŷ Efficiency ★★★ according to European Directive EEC 92/42
(on room-sealed models).
Ŷ Two air inlet holes (right and left side).
Ŷ Expansion vessel 8 litres.
Ŷ 3-speed circulator, located on the right side of the boiler (no ErP models).
INTERAXES AND HYDRAULIC Ŷ Intuitive and easy-to-use control panel with backlit digital display.
FITTINGS POSITIONING
CH DHW Gas DHW CH Ŷ Compact dimensions and low lift weight enable a flexible installation with
F O G I R
the boiler able to be sited almost anywhere in the home.
65 120 60 55 Ŷ NEW DIN connections, to enable an easy installation both as a
replacement or in new buildings with the same configuration.
Ŷ Built-in thermoregulation (external temperature probe as option).
Ŷ Hydraulic connections, gas and DHW taps available as option.
Ŷ QUADRA II can be converted to LPG through specific LPG kit (as option).
Ŷ Can be matched with BeSMART Control working as WiFi
thermostat in OTBus communication, allowing exstensive TOP
advantages.

Conventional flue

DIMENSIONS DHW ENERGY CLASS


OUTPUT
CODE GAS MODEL H ×W × D PRODUCTION
(kW)
(mm) (l/min. - Δt 25 °C)
INSTANTANEOUS COMBI BOILERS

20095664 NG QUADRA II 24 C.A.I. 740 × 400 × 328 24.00 13,7

According to the European Directive ERP, the following products are not allowed
Conventional flue to be placed on the European market by the manufacturer since 01/08/2015

DIMENSIONS DHW
OUTPUT
CODE GAS MODEL H ×W × D PRODUCTION
(kW)
(mm) (l/min. - Δt 25 °C)
INSTANTANEOUS COMBI BOILERS

20084088 NG QUADRA II 24 C.A.I. 740 × 400 × 328 24.00 13,7

According to the European Directive ERP, the following products are not allowed
Room-sealed to be placed on the European market by the manufacturer since 01/08/2015

DIMENSIONS DHW
OUTPUT
CODE GAS MODEL H ×W × D PRODUCTION
(kW)
(mm) (l/min. - Δt 25 °C)
INSTANTANEOUS COMBI BOILERS

20084087 NG QUADRA II 24 C.S.I. 715 × 405 × 250 24.00 13,7

20097272 NG QUADRA II 28 C.S.I. 715 × 405 × 250 28.00 16,3

= NEW (the green rectangle identifies a new code)

82
Combi wall-hung boilers
QUADRA II

Comfort accessories for smartphone and tablet *

CODE DESCRIPTION

20111876 BeSMART WIFI CONTROL KIT (1)


20111878 BeSMART CONTROL (2)

STANDARD-EFFICIENCY
(*) For all information about BeSMART and its wide range of accessories, please refer to the first chapter of this catalogue “SMART SYSTEMS”.

BOILERS
(1) Complete kit for WiFi installation.
(2) Only BeSMART thermostat.

= NEW (the green rectangle identifies a new code)

Other accessories

CODE DESCRIPTION

Comfort accessories
20059641 ALPHA DGT WIRELESS digital room thermostat
20059639 ALPHA DGT digital room thermostat
20101748 ALPHA 7D WIRELESS 7-day digital room thermostat
20063872 ALPHA 7D 7-day digital room thermostat
20049748 Outdoor probe with connector
Hydraulic accessories
1101989 Heating taps
1101999 Heating taps with filter
20008794 Kit hydraulic connections (for welding)
20008795 Kit hydraulic connections (with brass nipples)
20025113 Solar diverter valve (including flexible stainless steel connection pipes)
1101979 High head pump (6 metres) - for non-ErP boilers
20105959 High head Low Energy pump (7 metres) - for ErP boilers
Special accessories
20012594 Lower cover
20012595 Upper cover

83
Combi wall-hung boilers
CIAO

Ŷ On ErP boilers: Low Energy, synchronous pump EEI ≤ 0.20.


Ŷ Bithermic heat-exchanger.
Ŷ Efficiency ★★★ according to European Directive EEC 92/42
(on room-sealed models).
Ŷ Two air inlet holes (right and left side).
Ŷ Expansion vessel 8 litres.
Ŷ 4 metres single-speed circulator on 20-24 kW versions (non-ErP
boilers).
INTERAXES AND HYDRAULIC Ŷ 5 metres 3-speed circulator on 28 kW versions (non-ErP boilers).
FITTINGS POSITIONING
Central heating Gas Domestic water Ŷ Intuitive and easy-to-use control panel with backlit digital display.
R F G O I Ŷ Built-in thermoregulation (external temperature probe as option).
65 120 60 55 Ŷ IPX5D electrical protection.
Ŷ Frost protection kit till -10 °C available as option.
Ŷ Upper and lower cover availbale as option (on 20-24 C.S.I. models).
Ŷ Hydraulic connections, gas and DHW taps available as option.
Ŷ Can be matched with BeSMART Control working as WiFi
thermostat in OTBus communication, allowing exstensive TOP
advantages.

Conventional flue

DIMENSIONS DHW ENERGY CLASS


OUTPUT
CODE GAS MODEL H ×W × D PRODUCTION
(kW)
(mm) (l/min. - Δt 25 °C)
INSTANTANEOUS COMBI BOILERS

20096542 NG CIAO 24 C.A.I. e 740 × 400 × 332 24.00 13,6

20096546 NG CIAO 28 C.A.I. e 740 × 400 × 332 28.00 16,3

According to the European Directive ERP, the following products are not allowed
Conventional flue to be placed on the European market by the manufacturer since 01/08/2015

DIMENSIONS DHW
OUTPUT
CODE GAS MODEL H ×W × D PRODUCTION
(kW)
(mm) (l/min. - Δt 25 °C)
INSTANTANEOUS COMBI BOILERS

20070518 NG CIAO 24 C.A.I. e 740 × 400 × 332 24.00 13,6

20070520 NG CIAO 28 C.A.I. e 740 × 400 × 332 28.00 16,3

According to the European Directive ERP, the following products are not allowed
Room-sealed to be placed on the European market by the manufacturer since 01/08/2015

DIMENSIONS DHW
OUTPUT
CODE GAS MODEL H ×W × D PRODUCTION
(kW)
(mm) (l/min. - Δt 25 °C)
INSTANTANEOUS COMBI BOILERS

20084048 NG CIAO 20 C.S.I. e 715 × 405 × 248 20.00 11,8

20070516 NG CIAO 24 C.S.I. e 715 × 405 × 248 24.00 13,7

84
Combi wall-hung boilers
CIAO

According to the European Directive ERP, the following products are not allowed
Room-sealed to be placed on the European market by the manufacturer since 01/08/2015

DIMENSIONS DHW
OUTPUT
CODE GAS MODEL H ×W × D PRODUCTION
(kW)
(mm) (l/min. - Δt 25 °C)
INSTANTANEOUS COMBI BOILERS

STANDARD-EFFICIENCY
20070521 LPG CIAO 24 C.S.I. e 715 × 405 × 248 24.00 13,7

BOILERS
20070517 NG CIAO 28 C.S.I. e 740 × 450 × 332 28.00 16,2

20070522 LPG CIAO 28 C.S.I. e 740 × 450 × 332 28.00 16,2

Comfort accessories for smartphone and tablet *

CODE DESCRIPTION CODE DESCRIPTION

20111876 BeSMART WIFI CONTROL KIT (1) 20111878 BeSMART CONTROL (2)
(*) For all information about BeSMART and its wide range of accessories, please refer to the first chapter of this catalogue “SMART SYSTEMS”.
(1) Complete kit for WiFi installation.
(2) Only BeSMART thermostat.

= NEW (the green rectangle identifies a new code)

Other accessories

CODE DESCRIPTION CODE DESCRIPTION

Comfort accessories 20008794 Kit hydraulic connections (for welding)


20059641 ALPHA DGT WIRELESS digital room thermostat 20008795 Kit hydraulic connections (with brass nipples)
20059639 ALPHA DGT digital room thermostat High head pump - 6 metres (for 20-24 C.S.I models)
1101979
- for non-ErP boilers
20101748 ALPHA 7D WIRELESS 7-day digital room thermostat High head pump - 6 metres (for 24 C.A.I.,
1101769
20063872 ALPHA 7D 7-day digital room thermostat 28 C.A.I./C.S.I. models) - for non-ErP boilers
20105959 High head Low Energy pump (7 metres) - for ErP boilers
20049748 Outdoor probe with connector
Special accessories
Hydraulic accessories
20012594 Lower cover (only for CIAO 20-24 C.S.I)
1101989 Heating taps
20012595 Upper cover (only for CIAO 20-24 C.S.I)
1101999 Heating taps with filter
Frost protection resistances kit till -10°C
Solar diverter valve (including flexible 20017044
20025113 (only for CIAO 20-24 C.S.I)*
stainless steel connection pipes)
(*) Together with the installation of the frost protection resistances kit (code 20017044), it is necessary to install the lower cover (code 20012594).

85
Combi wall-hung boilers with built-in DHW tank
MYNUTE BOILER

Ŷ On ErP boilers: Low Energy, synchronous pump EEI ≤ 0.20.


Ŷ Built-in stainless steel DHW tank with magnesium anode
(capacity: 45 lt. on 24/45 B.S.I. model; 60 lt. on 28/60 B.S.I. and B.A.I.
models).
Ŷ Primary heat exchanger in copper.
Ŷ Efficiency ★★★ according to European Directive EEC 92/42.
INTERAXES AND HYDRAULIC Ŷ Built-in thermoregulation (with external probe available as option).
FITTINGS POSITIONING
Central heating Gas Domestic water Ŷ IPX5D electrical protection.
R F G O RC I
Ŷ Expansion vessel 10 litres, DHW expansion vessel 2 litres.
65 85 108 90 90 Ŷ 3-speed circulator 5 metres.
Ŷ Intuitive and easy-to-use control panel with backlit digital display.
Ŷ Hydraulic connections, gas and DHW taps available as option.
Ŷ Can be matched with BeSMART Control working as WiFi
thermostat in OTBus communication, allowing exstensive TOP
advantages.

Conventional flue

DIMENSIONS DHW TANK ENERGY CLASS


OUTPUT
CODE GAS MODEL H ×W × D CAPACITY
(kW)
(mm) (litres)
COMBI BOILERS WITH BUILT-IN DHW TANK

MYNUTE BOILER
20100127 NG 940 × 600 × 465 28.00 60
28/60 B.A.I.

According to the European Directive ERP, the following products are not allowed
Conventional flue to be placed on the European market by the manufacturer since 01/08/2015

DIMENSIONS DHW TANK


OUTPUT
CODE GAS MODEL H ×W × D CAPACITY
(kW)
(mm) (litres)
COMBI BOILERS WITH BUILT-IN DHW TANK
MYNUTE BOILER
20074642 NG 940 × 600 × 465 28.00 60
28/60 B.A.I.

According to the European Directive ERP, the following products are not allowed
Room-sealed to be placed on the European market by the manufacturer since 01/08/2015

DIMENSIONS DHW TANK


OUTPUT
CODE GAS MODEL H ×W × D CAPACITY
(kW)
(mm) (litres)
COMBI BOILERS WITH BUILT-IN DHW TANK

MYNUTE BOILER
20071343 NG 940 × 600 × 465 24.00 45
24/45 B.S.I.
MYNUTE BOILER
20071344 NG 940 × 600 × 465 28.00 60
28/60 B.S.I.

86
Combi wall-hung boilers with built-in DHW tank
MYNUTE BOILER

Comfort accessories for smartphone and tablet *

CODE DESCRIPTION

20111876 BeSMART WIFI CONTROL KIT (1)


20111878 BeSMART CONTROL (2)

STANDARD-EFFICIENCY
(*) For all information about BeSMART and its wide range of accessories, please refer to the first chapter of this catalogue “SMART SYSTEMS”.

BOILERS
(1) Complete kit for WiFi installation.
(2) Only BeSMART thermostat.

= NEW (the green rectangle identifies a new code)

Other accessories

CODE DESCRIPTION

Comfort accessories
20059641 ALPHA DGT WIRELESS digital room thermostat
20059639 ALPHA DGT digital room thermostat
20101748 ALPHA 7D WIRELESS 7-day digital room thermostat
20063872 ALPHA 7D 7-day digital room thermostat
20049748 Outdoor probe with connector
Hydraulic accessories
20085814 Wall hydraulic connections kit
1103479 DHW recirculation kit
1101989 Heating taps
1101999 Heating taps with filter
1221209 Multi-zones electronic board to be used with REC05
1101979 High head pump - 6 metres (for 20-24 C.S.I. models) - for non-ErP boilers
20105959 High head Low Energy pump (7 metres) - for ErP boilers

87
‘Heating only’ cast-iron floor-standing boilers
NOVELLA

Ŷ High quality cast-iron heat-exchanger.


Ŷ Electronic ignition with ionization flame control.
Ŷ Possibility of multi-zones circuits management with external
connections.
Ŷ IP40 electrical protection.
Ŷ Suitable for connection with Beretta DHW tanks.
Ŷ Can be converted to LPG through LPG kit (supplied as standard).
Ŷ Can be matched with BeSMART Control working as WiFi
thermostat (no OTBus communication).

According to the European Directive ERP, the following products are not allowed
Conventional flue to be placed on the European market by the manufacturer since 01/08/2015

DIMENSIONS OUTPUT
CODE GAS MODEL H ×W × D (kW)
(mm)
HEATING ONLY BOILERS

442943 NG NOVELLA 31 R.A.I. 850 × 450 × 675 31.0

443043 NG NOVELLA 45 R.A.I. 850 × 600 × 720 45.0

443053 NG NOVELLA 55 R.A.I.* 850 × 450 × 712 55.0

443063 NG NOVELLA 64 R.A.I.* 850 × 450 × 795 63.5

443073 NG NOVELLA 71 R.A.I.** 850 × 450 × 878 71.1


* In addition to the boilers Novella 55 R.A.I. e Novella 64 R.A.I. it is necessary to order the code 480213: anti-refouleur kit Ø 180 mm.
** In addition to the boiler Novella 71 R.A.I. it is necessary to order the code 480214: anti-refouleur kit Ø 200 mm.

Comfort accessories for smartphone and tablet *

CODE DESCRIPTION CODE DESCRIPTION

20111876 BeSMART WIFI CONTROL KIT (1) 20111878 BeSMART CONTROL (2)
(*) For all information about BeSMART and its wide range of accessories, please refer to the first chapter of this catalogue “SMART SYSTEMS”.
(1) Complete kit for WiFi installation.
(2) Only BeSMART thermostat.
= NEW (the green rectangle identifies a new code)

Other accessories

CODE DESCRIPTION CODE DESCRIPTION


Flues accessories 20063872 ALPHA 7D 7-day digital room thermostat
Anti-refouleur kit Ø 180 mm 1100689 Multi-zones electrical kit with circulators or valves
480213
(for Novella 55 R.A.I. and 64 R.A.I.)
Hydraulic accessories
480214 Anti-refouleur kit Ø 200 mm (for Novella 71 R.A.I.)
1100269 High head circulator
Comfort accessories
Special accessories
20059641 ALPHA DGT WIRELESS digital room thermostat
20051957 Electric connections kit (only for BV tanks)
20059639 ALPHA DGT digital room thermostat
20101748 ALPHA 7D WIRELESS 7-day digital room thermostat

88
‘Heating only’ cast-iron floor-standing boilers
NOVELLA

Ŷ High quality cast-iron heat-exchanger.


Ŷ Piezoelectric ignition with ionization flame control.
Ŷ Standard efficiency, higher than 90%.
Ŷ Compact sizes: it is suitable for the installation in any kind of plant
room.
Ŷ Thermostatic control board provided with a total shut-off function.
Ŷ Can be converted to LPG through LPG kit (supplied as option).

STANDARD-EFFICIENCY
Ŷ Can be matched with BeSMART Control working as WiFi

BOILERS
thermostat (no OTBus communication).

According to the European Directive ERP, the following products are not allowed
Conventional flue to be placed on the European market by the manufacturer since 01/08/2015

DIMENSIONS OUTPUT
CODE GAS MODEL H ×W × D (kW)
(mm)
HEATING ONLY BOILERS

1650633 NG NOVELLA 45 R.A.P.* 850 × 600 × 720 45.0

1650653 NG NOVELLA 55 R.A.P.** 850 × 450 × 712 55.0

1650673 NG NOVELLA 64 R.A.P.** 850 × 450 × 795 63.5

1650693 NG NOVELLA 71 R.A.P.*** 850 × 450 × 878 71.1


* Built-in anti-refouleur kit Ø 180 mm.
** In addition to the boilers Novella 55 R.A.P. e Novella 64 R.A.P. it is necessary to order the code 480213: anti-refouleur kit Ø 180 mm.
*** In addition to the boiler Novella 71 R.A.P. it is necessary to order the code 480214: anti-refouleur kit Ø 200 mm.

Comfort accessories for smartphone and tablet *

CODE DESCRIPTION CODE DESCRIPTION

20111876 BeSMART WIFI CONTROL KIT (1) 20111878 BeSMART CONTROL (2)
(*) For all information about BeSMART and its wide range of accessories, please refer to the first chapter of this catalogue “SMART SYSTEMS”.
(1) Complete kit for WiFi installation.
(2) Only BeSMART thermostat.
= NEW (the green rectangle identifies a new code)

Other accessories

CODE DESCRIPTION CODE DESCRIPTION

Flues accessories Flues accessories


Anti-refouleur kit Ø 180 mm 480214 Anti-refouleur kit Ø 200 mm (for Novella 71 R.A.P.)
480213
(for Novella 55 R.A.P. and 64 R.A.P.)

89
‘Heating only’ cast-iron floor-standing boilers
NOVELLA MAXIMA

Ŷ High quality cast-iron heat-exchanger.


Ŷ Electronic ignition with ionization flame control.
Ŷ Possibility of multi-zones circuits management with external connections.
Ŷ IP40 electrical protection.
Ŷ Suitable for connection with Beretta DHW tanks.
Ŷ NOVELLA MAXIMA can be converted to LPG through LPG kit
(available as option).
Ŷ Can be matched with BeSMART Control working as WiFi
thermostat (no OTBus communication).

According to the European Directive ERP, the following products are not allowed
Conventional flue to be placed on the European market by the manufacturer since 01/08/2015

DIMENSIONS
OUTPUT
CODE DESCRIPTION GAS MODEL H ×W × D
(kW)
(mm)
HEATING ONLY BOILERS

20047058 - NG NOVELLA MAXIMA 90 N R.A.I. 1000 × 1040 × 645 90.0

20047059 - NG NOVELLA MAXIMA 99 N R.A.I. 1000 × 1140 × 645 98.6

20047060 - NG NOVELLA MAXIMA 108 N R.A.I. 1000 × 1240 × 670 107.9

20047061 Body
20047069 Casing & Flue Hood NG NOVELLA MAXIMA 129 N R.A.I.*** 1365 × 810 × 1110 129.0
20047077 Control Board & Gas Valve
20047062 Body
20047070 Casing & Flue Hood NG NOVELLA MAXIMA 151 N R.A.I.*** 1365 ×920 × 1110 150.6
20047079 Control Board & Gas Valve
20047063 Body
20047071 Casing & Flue Hood NG NOVELLA MAXIMA 172 N R.A.I.*** 1365 ×1.030 × 1110 172.2
20047080 Control Board & Gas Valve
20047064 Body
20047072 Casing & Flue Hood NG NOVELLA MAXIMA 194 N R.A.I.*** 1365 ×1145 × 1140 193.7
20047081 Control Board & Gas Valve
20047065 Body
20047073 Casing & Flue Hood NG NOVELLA MAXIMA 215 N R.A.I.*** 1365 ×1255 × 1140 215.2
20047082 Control Board & Gas Valve
20047066 Body
20047074 Casing & Flue Hood NG NOVELLA MAXIMA 237 N R.A.I.*** 1365 ×1370 × 1190 236.5
20047083 Control Board & Gas Valve

90
‘Heating only’ cast-iron floor-standing boilers
NOVELLA MAXIMA

DIMENSIONS
OUTPUT
CODE DESCRIPTION GAS MODEL H ×W × D
(kW)
(mm)
HEATING ONLY BOILERS

20047067 Body
20047075 Casing & Flue Hood NG NOVELLA MAXIMA 258 N R.A.I.*** 1365 ×1480 × 1190 257.8
20047084 Control Board & Gas Valve

STANDARD-EFFICIENCY
20047068 Body

BOILERS
20047076 Casing & Flue Hood NG NOVELLA MAXIMA 279 N R.A.I.*** 1365 ×1580 × 1190 279.1
20047085 Control Board & Gas Valve
*** To purchase the complete product, please remember to order the three codes. For more details, please contact Sales Department.

Comfort accessories for smartphone and tablet *

CODE DESCRIPTION

20111876 BeSMART WIFI CONTROL KIT (1)


20111878 BeSMART CONTROL (2)
(*) For all information about BeSMART and its wide range of accessories, please refer to the first chapter of this catalogue “SMART SYSTEMS”.
(1) Complete kit for WiFi installation.
(2) Only BeSMART thermostat.

= NEW (the green rectangle identifies a new code)

91
92
WATER HEATERS
WATER HEATERS

93
Instantaneous water-heaters
IDRABAGNO ESI

Ŷ Room-sealed fan-assisted water-heater.


INTERAXES AND HYDRAULIC Ŷ Electronic modulation flame.
FITTINGS POSITIONING
DHW Gas DCW Ŷ Temperature selector.
O G I Ŷ Operating mode and anomalies led indicators.
74 74 Ŷ Frost protection kit (optional).
Ŷ Electrical supply 230 V.
Ŷ IPX4D electrical protection.

Room-sealed

DIMENSIONS DHW ENERGY CLASS


OUTPUT
CODE GAS MODEL H ×W × D PRODUCTION
(kW)
(mm) (l/min. - Δt 25 °C)
IONISATION FLAME - ELECTRONIC IGNITION

20108085 NG IDRABAGNO 11 ESI 640 × 400 × 246 20.6 11 M*

20108088 LPG IDRABAGNO 11 ESI 640 × 400 × 246 20.6 11 M*

20108090 NG IDRABAGNO 13 ESI 640 × 400 × 246 23.9 13 *

20108093 LPG IDRABAGNO 13 ESI 640 × 400 × 246 23.9 13 *

20108099 NG IDRABAGNO 17 ESI 640 × 400 × 246 27.9 17 *

20108101 LPG IDRABAGNO 17 ESI 640 × 400 × 246 27.9 17 *

* Load profile
For the installation of IDRABAGNO 11 ESI and 13 ESI under low temperature conditions (down to -10°C), it is available the frost protection kit with covers (code 20115865).

Accessories

CODE DESCRIPTION
Specific accessories
1100499 Hydraulic taps
1100519 Gas straight tap
1100509 Gas tap ¾” right-angle (Idrabagno ESI)
20115865 Frost protection resistances kit with cover (model 11 ESI - 13 ESI)

= NEW (the green rectangle identifies a new code)

94
Instantaneous water-heaters
FONTE AP/AE

Ŷ Conventional-flue water-heater.
INTERAXES AND HYDRAULIC Ŷ Continuous flame modulation feature.
FITTINGS POSITIONING 11 AP/AE
DHW Gas DCW
Ŷ Gas-saver function.
O G I
Ŷ Intuitive and user-friendly control panel, with
128 87
DHW temperature selector.
Ŷ Versions with electronic ignition (AE) and piezoelectric (AP)
Ŷ 1.5 V battery ignition (AE models).
INTERAXES AND HYDRAULIC
FITTINGS POSITIONING 14 AP/AE
DHW Gas DCW
O G I
148 87

WATER HEATERS
Conventional flue

DIMENSIONS DHW ENERGY CLASS


OUTPUT
CODE GAS MODEL H ×W × D RODUCTION
(kW)
(mm) (l/min. - Δt 25 °C)
PILOTE FLAME - PIEZOELECTRIC IGNITION

20015354 NG FONTE 11 AP 592 × 314 × 245 18.9 11 M*


20015355 LPG FONTE 11 AP 592 × 314 × 245 18.9 11 M*
20015368 NG FONTE 14 AP 650 × 363 × 245 23.7 14 *

20015369 LPG FONTE 14 AP 650 × 363 × 245 23.7 14 *


* Load profile

IONISATION FLAME - BATTERY IGNITION

20015356 NG FONTE 11 AE 592 × 314 × 245 18.9 11 M*


20015367 LPG FONTE 11 AE 592 × 314 × 245 18.9 11 M*
20015370 NG FONTE 14 AE 650 × 363 × 245 23.7 14 *

20015371 LPG FONTE 14 AE 650 × 363 × 245 23.7 14 *


* Load profile

Accessories

CODE DESCRIPTION

Specific accessories
20020922 Hydraulic connections kit with DHW tap - Fonte 11 AP/AE

20020923 Hydraulic connections kit with DHW tap - Fonte 14 AP/AE

95
96
ACCESSORIES
FLUES AND
FLUES AND
ACCESSORIES

97
Flue lengths
MAXIMUM FLUE LENGTHS TABLE

Condensing wall-hung boilers


Concentric horizontal Twin
MAX FLUE LENGTHS
60/100 80/125 80-80 Flue configuration approval
B23P-B53P-C13-C13x-C33-C33x-C43-C43x-C53-
MySMART 28 C.S.I. 7.80m 20.00m 50m + 50m
C53x-C63-C63x-C83-C83x-C93-C93x-3CEp
Exclusive GREEN E 25 C.S.I./R.S.I. 7.85m 20.00m 50m + 50m
B23P-B53P-C13-C13x-C23-C33-C33x-C43-C43x-
Exclusive GREEN E 30 C.S.I. 7.85m 20.00m 50m + 50m
C53-C53x-C63-C63x-C83-C83x-C93-C93x
Exclusive GREEN E 35 C.S.I./R.S.I. 7.85 m 14.85 m 38m + 38m
Exclusive BOILER GREEN HE 25 B.S.I. 7.85 m 14.85 m 32 m + 32 m B23P-B53P-C13-C13x-C23-C33-C33x-C43-C43x-
Exclusive BOILER GREEN HE 35 B.S.I. 7.85 m 14.85 m 40 m + 40 m C53-C53x-C63-C63x-C83-C83x-C93-C93x
B23P-B53P-C13-C13x-C23-C33-C33x-C43-C43x-
Exclusive BOILER GREEN 30 B.S.I. 7.80 m 18.00 m 35 m + 35 m
C53-C53x-C63-C63x-C83-C83x
Mynute GREEN 12 R.S.I. E 7.85 m 14.85 m 60 m + 60 m B23P-B53P-C13-C13x-C23-C33-C33x-C43-C43x-
Mynute GREEN 15 R.S.I. E 7.85 m 14.85 m 50 m + 50 m C53-C53x-C63-C63x-C83-C83x-C93-C93x
B23P-B53P-C13-C13x-C23-C33-C33x-C43-C43x-
Mynute GREEN 25 C.S.I./R.S.I. 7.85 m 14.85 m 36 m + 36 m
C53-C53x-C63-C63x-C83-C83x-C93-C93x-3CEp
Mynute GREEN 30 C.S.I. E 7.85 m 14.85 m 30 m + 30 m
Mynute GREEN 35 R.S.I. E 7.85 m 14.85 m 26 m + 26 m
B23P-B53P-C13-C13x-C23-C33-C33x-C43-C43x-
Mynute GREEN 38 C.S.I. E 3.85 m 10.00 m 30 m + 30 m
C53-C53x-C63-C63x-C83-C83x-C93-C93x
Mynute BOILER GREEN 25 B.S.I. E 7.85 m 14.85 m 36 m + 36 m
Mynute BOILER GREEN 32 B.S.I. E 7.85 m 14.85 m 35 m + 35 m
Mynute Sinthesi 25 C.S.I. 4.50m 11.00m 20m + 20m
Mynute Sinthesi 29 C.S.I. 4.00m 9.00m 12m + 12m B22P-B52P-C12-C12x-C22-C32-C32x-C42-C42x-
Ciao AT 25 C.S.I. 4.50m 11.00m 20m + 20m C52-C52x-C62-C62x-C82-C82x-C92-C92x
Ciao AT 29 C.S.I. 4.00m 9.00m 12m + 12m
Ciao GREEN 25 C.S.I./R.S.I. 5.85 m 15.30 m 45 m + 45 m
Ciao GREEN 29 C.S.I. 4.85 m 12.8 0m 40 m + 40 m B23P-B53P-C13-C13x-C23-C33-C33x-C43-C43x-
QUADRA GREEN 25 C.S.I./R.S.I. 5.85 m 15.30 m 45 m + 45 m C53-C53x-C63-C63x-C83-C83x-C93-C93x-3CEp
QUADRA GREEN 30 C.S.I.. 4.85 m 12.80 m 40 m + 40 m
B23P-B53P-C13-C13x-C23-C33-C33x-C43-C43x-
Mynute GREEN 50 R.S.I. 1.85 m 4.85 m 20 m + 20 m
C53-C53x-C63-C63x-C83-C83x

Condensing floor-standing boilers

Concentric horizontal Twin


MAX FLUE LENGTHS
60/100 80/125 80-80 Flue configuration approval
Tower GREEN HE 35/120 B.S.I. 7.85 m 14.85 m 40 m + 40 m
Tower GREEN HE S 35/200 B.S.I. 7.85 m 14.85 m 40 m + 40 m
Tower GREEN HE 35/60 B.S.I. 7.85 m 14.85 m 40 m + 40 m B23P-B53P-C13-C13x-C23-C33-C33x-C43-C43x-
Tower GREEN HE 35 R.S.I. 7.85 m 14.85 m 40 m + 40 m C53-C53x-C63-C63x-C83-C83x-C93-C93x
Tower GREEN HE HYBRID S 35/200 B.S.I. 7.85 m 14.85 m 40 m + 40 m
Tower GREEN HE HYBRID 35/200 B.S.I. 7.85 m 14.85 m 40 m + 40 m

98
Flue lengths
MAXIMUM FLUE LENGTHS TABLE

Standard efficiency wall-hung boilers


Concentric horizontal Twin
MAX FLUE LENGTHS
60/100 80/125 80-80 Flue configuration approval
Exclusive MIX 26 C.S.I. 3.40 m 7.61 m 15 m + 15 m C12-C12x-C22-C32-C32x-C42-C42x-
Exclusive MIX 30 C.S.I./R.S.I. 3.40 m 7.61 m 14 m + 14 m C52-C52x-C62-C62x-C82-C82x
C12-C12x-C22-C32-C32x-C42-
Exclusive MIX 35 C.S.I./R.S.I. 2.00 m 4.26 m 6m + 6m
C42x-C62-C62x-C82-C82x
Mynute S 24 C.S.I. 4.25 m N.A. 20 m + 20 m
Mynute S 28 C.S.I./R.S.I. 3.40 m N.A. 14.5 m + 14.5 m
Mynute S 35 C.S.I./R.S.I. 2.30 m 5.85 m 8m + 8m B22P-B52P-C12-C12x-C22-C32-C32x-C42-C42x-
Ciao S 20 C.S.I. 4.25 m 12.40 m 10 m + 10 m C52-C52x-C62-C62x-C82-C82x-C92-C92x
Ciao S 24 C.S.I./R.S.I. 4.25 m 12.40 m 16 m + 16 m
Quadra II 24 C.S.I. 4.25 m 12.40 m 16 m + 16 m
B22P-B52P-C12-C12x-C32-C32x-C42-C42x-
Quadra II 28 C.S.I. 3.40m 10.0m 14.5m+14.5m
C52-C52x-C62-C62x-C82-C82x-C92-C92x
Ciao 20 C.S.I. e 4.25 m 12.40 m 10 m + 10 m
Ciao 24 C.S.I. e 4.25 m 12.40 m 16 m + 16 m
B22P-B52P-C12-C12x-C22-C32-C32x-C42-C42x-
Ciao 28 C.S.I. e 3.40 m 10 .0m 14 m + 14 m
C52-C52x-C62-C62x-C82-C82x-C92-C92x
Mynute Boiler 24/45 B.S.I. 4.25 m 10.5 m 20 m + 20 m
Mynute Boiler 28/60 B.S.I. 3.40 m 8.5 m 17 m + 17 m

Istantaneous water heaters

ACCESSORIES
FLUES AND
Concentric horizontal Twin
MAX FLUE LENGTHS
60/100 80/125 80-80 Flue configuration approval
Idrabagno 11 ESI 4.25 m 12.4m 10m +10 m
B22-B52-C12-C12x-C22-C32-C32x-C42-C42x-
Idrabagno 13 ESI 4.25m 12.4m 16m+16m
C52-C52x-C62-C62x-C82-C82x-C92-C92x
Idrabagno 17 ESI 3.40m N.A. 14.5m+14.5m

Losses
Concentric horizontal Twin
MAX FLUE LENGTHS
60/100 80/125 80-80
45° bend standard efficiency 1.0 m 1.35 m 1.2 m
90° bend standard efficiency 1.5 m 2.2 m 1.7 m
45° bend condensing 1.3 m 1.0 m 1.0 m
90° bend condensing 1.6 m 1.5 m 1.5 m

99
Condensing
FLUE OPTIONS

Ø 80 twin flue system in plastic (PP) for condensing boilers

FLOOR-STANDING BOILERS
Exclusive BOILER GREEN HE

Mynute GREEN 50 R.S.I.


WALL-HUNG BOILERS

Mynute BOILER GREEN


Exclusive GREEN E

Tower GREEN HE
Mynute Sinthesi
Mynute GREEN

Quadra GREEN
Ciao GREEN
MySMART

Ciao AT
code 20062932

Q Q

Ø80 TWIN SYSTEM KIT

code 20027292

Q Q Q Q Q Q Q Q

Ø80 TWIN SYSTEM KIT

code 20027266

Q Q Q Q Q Q Q Q Q Q Q

Ø80 45°BEND

code 20027262

Q Q Q Q Q Q Q Q Q Q Q

Ø80 90°BEND

code 20027219

Q Q Q Q Q Q Q Q Q Q Q

Ø80 EXTENSION 500 mm

code 20027222

Q Q Q Q Q Q Q Q Q Q Q

Ø80 EXTENSION 1000 mm

code 20027226

Q Q Q Q Q Q Q Q Q Q Q

Ø80 EXTENSION 2000 mm

code 20027272

Q Q Q Q Q Q Q Q Q Q Q

Ø80 HORIZONTAL FLUE TERMINAL 985 mm

code 20027276

Q Q Q Q Q Q Q Q Q Q Q

Ø 80 AIR INLET HORIZONTAL TERMINAL 662 mm

Due to exposition to sunlight, the colour of the material (PP) may be altered.

100
Condensing
FLUE OPTIONS

Ø 80 twin flue system in plastic (PP) for condensing boilers

FLOOR-STANDING BOILERS
Exclusive BOILER GREEN HE

Mynute GREEN 50 R.S.I.


WALL-HUNG BOILERS

Mynute BOILER GREEN


Exclusive GREEN E

Tower GREEN HE
Mynute Sinthesi
Mynute GREEN

Quadra GREEN
Ciao GREEN
MySMART

Ciao AT
code 20027300

Q Q Q Q Q Q Q Q Q Q Q
FLUE ADAPTER from Ø 60/100 to Ø 80 FOR
B23 INSTALLATION with AIR INLET

code 20027195

Q Q Q Q Q Q Q Q Q Q Q
Ø 60-80 FLUE ADAPTER FOR INSTALLATION
TYPE B23 and AIR INLET

ACCESSORIES
FLUES AND
code 1100229

Q Q Q Q Q Q Q Q Q Q Q

Ø 80 SPACERS FOR PIPE (4 pcs. pack)

code 20028478

AIR INLET KIT FOR INSTALLATION TYPE B23

Due to exposition to sunlight, the colour of the material (PP) may be altered.

101
Condensing
FLUE OPTIONS

Ø 80 twin flue system in aluminium for condensing boilers

FLOOR-STANDING BOILERS
Exclusive BOILER GREEN HE

Mynute GREEN 50 R.S.I.


WALL-HUNG BOILERS

Mynute BOILER GREEN


Exclusive GREEN E

Tower GREEN HE
Mynute Sinthesi
Mynute GREEN

Quadra GREEN
Ciao GREEN
MySMART

Ciao AT
code 1102019

Q Q Q Q Q Q Q Q Q Q

Ø 80 TWIN SYSTEM KIT

code 1101899

Q Q Q Q Q Q Q Q Q Q Q

Ø 80 45°BEND

code 1101909

Q Q Q Q Q Q Q Q Q Q Q

Ø 80 90°BEND

code 1101929

Q Q Q Q Q Q Q Q Q Q Q

Ø 80 EXTENSION 500 mm

code 1101939

Q Q Q Q Q Q Q Q Q Q Q

Ø 80 EXTENSION 1000 mm

code 1101949

Q Q Q Q Q Q Q Q Q Q Q

Ø 80 EXTENSION 2000 mm

code 1101969

Q Q Q Q Q Q Q Q Q Q Q

Ø 80 HORIZONTAL FLUE TERMINAL

code 1100139

Q Q Q Q Q Q Q Q Q Q Q

Ø 80 AIR INLET HORIZONTAL TERMINAL

102
Condensing
FLUE OPTIONS

Ø 80 twin flue system in aluminium for condensing boilers

FLOOR-STANDING BOILERS
Exclusive BOILER GREEN HE

Mynute GREEN 50 R.S.I.


WALL-HUNG BOILERS

Mynute BOILER GREEN


Exclusive GREEN E

Tower GREEN HE
Mynute Sinthesi
Mynute GREEN

Quadra GREEN
Ciao GREEN
MySMART

Ciao AT
code 1102279

Q Q Q Q Q Q

Ø 80 FLUE ADAPTER with AIR INLET

code 20014659

Q Q Q Q Q Q Q Q Q Q Q

Ø 80 FLUE ADAPTER with AIR INLET

ACCESSORIES
FLUES AND
code 1100229

Q Q Q Q Q Q Q Q Q Q Q

Ø 80 SPACERS FOR PIPE (4 pcs. pack)

103
Condensing
FLUE OPTIONS

Ø 60/100 concentric flue system in plastic (PP/PPu) for condensing boilers

FLOOR-STANDING BOILERS
Exclusive BOILER GREEN HE

Mynute GREEN 50 R.S.I.


WALL-HUNG BOILERS

Mynute BOILER GREEN


Exclusive GREEN E

Tower GREEN HE
Mynute Sinthesi
Mynute GREEN

Quadra GREEN
Ciao GREEN
MySMART

Ciao AT
code 20027212

Q Q Q Q Q Q Q Q Q Q Q
Ø 60/100 VERTICAL FLUE TERMINAL
Ø 125 EXTERNAL STRAIGHT PIPE

code 20027555

Q Q Q Q Q Q Q Q Q Q Q

Ø 60/100 HORIZONTAL FLUE TERMINAL

code 20027161

Q Q Q Q Q Q Q Q Q Q Q

Ø 60/100 CONCENTRIC EXTENSION 500 mm

code 20027166

Q Q Q Q Q Q Q Q Q Q

Ø 60/100 CONCENTRIC EXTENSION 1000 mm

code 20027179

Q Q Q Q Q Q Q Q Q Q

Ø 60/100 CONCENTRIC EXTENSION 2000 mm

code 20027192

Q Q Q Q Q Q Q Q Q Q Q

Ø 60/100 45°CONCENTRIC BEND

code 20027185

Q Q Q Q Q Q Q Q Q Q Q

Ø 60/100 45°CONCENTRIC BEND (2 pcs.)

code 20027201

Q Q Q Q Q Q Q Q Q Q Q

Ø 60/100 90°CONCENTRIC BEND

code 20041110

Q Q

Ø 60/100 90°CONCENTRIC BEND FOR REAR FLUE EXIT

104
Condensing
FLUE OPTIONS

Ø 60/100 concentric flue system in plastic (PP/PPu) for condensing boilers

FLOOR-STANDING BOILERS
Exclusive BOILER GREEN HE

Mynute GREEN 50 R.S.I.


WALL-HUNG BOILERS

Mynute BOILER GREEN


Exclusive GREEN E

Tower GREEN HE
Mynute Sinthesi
Mynute GREEN

Quadra GREEN
Ciao GREEN
MySMART

Ciao AT
code 1100069

Q Q Q Q Q Q Q Q Q Q Q

Ø 125 PITCHED ROOF TILE FOR VERTICAL FLUE

code 1100059

Q Q Q Q Q Q Q Q Q Q Q

Ø 125 FLAT ROOF TILE FOR VERTICAL FLUE

ACCESSORIES
FLUES AND
code 1100129

Q Q Q Q Q Q Q Q Q Q Q

Ø 100 SPACERS FOR PIPE (4 pcs. pack)

code 20028027

FLUE ADAPTER KIT from Ø 80-80 to Ø 60/100

code 20027209

Q Q Q Q Q Q Q

Ø60/100 EXTENTION with INSPECTION DOOR

105
Condensing
FLUE OPTIONS

Ø 60/100 concentric flue system in PP/Met for condensing boilers

FLOOR-STANDING BOILERS
Exclusive BOILER GREEN HE

Mynute GREEN 50 R.S.I.


WALL-HUNG BOILERS

Mynute BOILER GREEN


Exclusive GREEN E

Tower GREEN HE
Mynute Sinthesi
Mynute GREEN

Quadra GREEN
Ciao GREEN
MySMART

Ciao AT
code 1101889

Q Q Q Q Q Q Q Q Q Q
Ø 60/100 VERTICAL FLUE TERMINAL
Ø 125 EXTERNAL STRAIGHT PIPE

code 1101879

Q Q Q Q Q Q Q Q Q Q

Ø 60/100 HORIZONTAL FLUE TERMINAL

code 1101839

Q Q Q Q Q Q Q Q Q Q

Ø 60/100 CONCENTRIC EXTENSION 500 mm

code 1101849

Q Q Q Q Q Q Q Q Q Q

Ø 60/100 CONCENTRIC EXTENSION 1000 mm

code 1101859

Q Q Q Q Q Q Q Q Q Q

Ø 60/100 CONCENTRIC EXTENSION 2000 mm

code 1101809

Q Q Q Q Q Q Q Q Q Q

Ø 60/100 45°CONCENTRIC BEND

code 1101819

Q Q Q Q Q Q Q Q Q Q

Ø 60/100 90°CONCENTRIC BEND

106
Condensing
FLUE OPTIONS

Ø 60/100 concentric flue system in PP/Met for condensing boilers

FLOOR-STANDING BOILERS
Exclusive BOILER GREEN HE

Mynute GREEN 50 R.S.I.


WALL-HUNG BOILERS

Mynute BOILER GREEN


Exclusive GREEN E

Tower GREEN HE
Mynute Sinthesi
Mynute GREEN

Quadra GREEN
Ciao GREEN
MySMART

Ciao AT
code 1100069

Q Q Q Q Q Q Q Q Q Q

Ø 125 PITCHED ROOF TILE FOR VERTICAL FLUE

code 1100059

Q Q Q Q Q Q Q Q Q Q

Ø 125 FLAT ROOF TILE FOR VERTICAL FLUE

ACCESSORIES
FLUES AND
code 1100129

Q Q Q Q Q Q Q Q Q Q

Ø 100 SPACERS FOR PIPE (4 pcs. pack)

107
Condensing
FLUE OPTIONS

Ø 80/125 concentric flue system in PP/Met for condensing boilers

FLOOR-STANDING BOILERS
Exclusive BOILER GREEN HE

Mynute GREEN 50 R.S.I.


WALL-HUNG BOILERS

Mynute BOILER GREEN


Exclusive GREEN E

Tower GREEN HE
Mynute Sinthesi
Mynute GREEN

Quadra GREEN
Ciao GREEN
MySMART

Ciao AT
code 1101599

Q Q Q Q Q Q Q Q Q Q Q

Ø 80/125 45°CONCENTRIC BEND

code 1101609

Q Q Q Q Q Q Q Q Q Q Q

Ø 80/125 90°CONCENTRIC BEND

code 1101619

Q Q Q Q Q Q Q Q Q Q Q

Ø 80/125 CONCENTRIC EXTENSION 500 mm

code 1101629

Q Q Q Q Q Q Q Q Q Q Q

Ø 80/125 CONCENTRIC EXTENSION 1000 mm

code 1101639

Q Q Q Q Q Q Q Q Q Q Q

Ø 80/125 CONCENTRIC EXTENSION 2000 mm

code 1101649

Q Q Q Q Q Q Q Q Q Q Q
Ø 80/125 90°CONCENTRIC BEND
with INSPECTION DOOR

code 1101659

Q Q Q Q Q Q Q Q Q Q Q
Ø 80/125 CONCENTRIC EXTENSION
with INSPECTION DOOR

code 20044868

Q Q
Ø 80/125 CLAPET KIT
with BUILT-IN CONDENSATE SYPHON for 3CEP

108
Condensing
FLUE OPTIONS

Ø 80/125 concentric flue system in PP/Met for condensing boilers

FLOOR-STANDING BOILERS
Exclusive BOILER GREEN HE

Mynute GREEN 50 R.S.I.


WALL-HUNG BOILERS

Mynute BOILER GREEN


Exclusive GREEN E

Tower GREEN HE
Mynute Sinthesi
Mynute GREEN

Quadra GREEN
Ciao GREEN
MySMART

Ciao AT
code 20082272

Q Q Q Q Q Q Q Q Q Q Q
Ø 80/125 VERTICAL FLUE TERMINAL (in PP/PPu);
Ø 125 EXTERNAL STRAIGHT PIPE

code 1101679

Q Q Q Q Q Q Q Q Q Q Q

Ø 80/125 HORIZONTAL FLUE TERMINAL (in PP/PPu)

ACCESSORIES
FLUES AND
code 1101689

Q Q Q Q Q Q Q Q Q Q Q

Ø 80/125 SPACERS (5 pcs. pack)

code 1100069

Q Q Q Q Q Q Q Q Q Q Q

Ø 125 PITCHED ROOF TILE FOR VERTICAL FLUE

code 1100059

Q Q Q Q Q Q Q Q Q Q Q

Ø 125 FLAT ROOF TILE FOR VERTICAL FLUE

code 1102269

Q Q Q Q Q Q Q Q Q Q

FLUE ADAPTER from Ø 60/100 to Ø 80/125

code 20028029

FLUE ADAPTER KIT from Ø 80-80 to Ø 80/125

109
Condensing
FLUE OPTIONS

Ø 60 flue range in plastic (PP) for inside-chimney installation, specific for condensing boilers

FLOOR-STANDING BOILERS
Exclusive BOILER GREEN HE

Mynute GREEN 50 R.S.I.


WALL-HUNG BOILERS

Mynute BOILER GREEN


Exclusive GREEN E

Tower GREEN HE
Mynute Sinthesi
Mynute GREEN

Quadra GREEN
Ciao GREEN
MySMART

Ciao AT
code 20046763

Q Q Q Q Q Q Q Q Q Q

Ø 60 45°BEND

code 20046760

Q Q Q Q Q Q Q Q Q Q

Ø 60 90°BEND

code 20046768

Q Q Q Q Q Q Q Q Q Q

Ø 60 EXTENSION 500 mm

code 20046770

Q Q Q Q Q Q Q Q Q Q

Ø 60 EXTENSION 1000 mm

code 20046771

Q Q Q Q Q Q Q Q Q Q

Ø 60 EXTENSION 2000 mm

code 20046772

Q Q Q Q Q Q Q Q Q Q
Ø 60/100 VERTICAL FLUE TERMINAL PP/PPu
Ø 100 EXTERNAL STRAIGHT PIPE

code 1101479

Q Q Q Q Q Q Q Q Q Q Q

Ø 60 T-CONNECTION

code 1101489

Q Q Q Q Q Q Q Q Q Q Q

Ø 60 CONDENSATE TRAP CAP FOR T-CONNECTION

code 1101369

Q Q Q Q Q Q Q Q Q Q Q

Ø 60 T-CONNECTION

110
Condensing
FLUE OPTIONS

Ø 60 flue range in plastic (PP) for inside-chimney installation, specific for condensing boilers

FLOOR-STANDING BOILERS
Exclusive BOILER GREEN HE

Mynute GREEN 50 R.S.I.


WALL-HUNG BOILERS

Mynute BOILER GREEN


Exclusive GREEN E

Tower GREEN HE
Mynute Sinthesi
Mynute GREEN

Quadra GREEN
Ciao GREEN
MySMART

Ciao AT
code 20046773

Q Q Q Q Q Q

Ø 60 3 SPACERS KIT FOR INSIDE-CHIMNEY

code 20046774

Q Q Q Q Q Q

SHELF SUPPORT KIT FOR INSIDE-CHIMNEY

ACCESSORIES
FLUES AND
code 20046775

Q Q Q Q Q Q

CHIMNEY FRONT COVER KIT

code 20046777

Q Q Q Q Q Q

Ø 60 5 HOSE CLAMPS KIT

code 20046778

Q Q Q Q Q Q

Ø 80-60 CHIMNEY CONNECTION KIT with Ø 60 90°BEND

code 20046779

Q Q Q Q Q Q

Ø 60 T-CONNECTION with CONDENSATE TRAP

code 20046782

Q Q Q Q Q Q

CONDENSATE SYPHON KIT

111
Condensing
FLUE OPTIONS

Ø 80 flue range in plastic (PP) for inside-chimney installation, specific for condensing boilers

FLOOR-STANDING BOILERS
Exclusive BOILER GREEN HE

Mynute GREEN 50 R.S.I.


WALL-HUNG BOILERS

Mynute BOILER GREEN


Exclusive GREEN E

Tower GREEN HE
Mynute Sinthesi
Mynute GREEN

Quadra GREEN
Ciao GREEN
MySMART

Ciao AT
code 1101299

Q Q Q Q Q Q Q Q Q Q Q

Ø 80 45°BEND

code 1101309

Q Q Q Q Q Q Q Q Q Q Q

Ø 80 90°BEND

code 1101319

Q Q Q Q Q Q Q Q Q Q Q

Ø 80 EXTENSION 500 mm

code 1101329

Q Q Q Q Q Q Q Q Q Q Q

Ø 80 EXTENSION 1000 mm

code 1101339

Q Q Q Q Q Q Q Q Q Q Q

Ø 80 EXTENSION 2000 mm

code 1101349

Q Q Q Q Q Q Q Q Q Q Q

Ø 80/125 CHIMNEY ADAPTER

code 20044862

Q
Ø 80 CLAPET KIT IN PP with BUILT-
IN CONDENSATE SYPHON

code 1101389

Q Q Q Q Q Q Q Q Q Q Q

Ø 80 CHIMNEY SUPPORT KIT

code 1101399

Q Q Q Q Q Q Q Q Q Q Q

PIPE SPACERS

112
Condensing
FLUE OPTIONS

Ø 80 flue range in plastic (PP) for inside-chimney installation, specific for condensing boilers

FLOOR-STANDING BOILERS
Exclusive BOILER GREEN HE

Mynute GREEN 50 R.S.I.


WALL-HUNG BOILERS

Mynute BOILER GREEN


Exclusive GREEN E

Tower GREEN HE
Mynute Sinthesi
Mynute GREEN

Quadra GREEN
Ciao GREEN
MySMART

Ciao AT
code 1101409

Q Q Q Q Q Q Q Q Q Q Q

Ø 80 INSPECTION EXTENSION

code 1101419

Q Q Q Q Q Q Q Q Q Q Q

Ø 80 ROOF TILE

ACCESSORIES
FLUES AND
code 1101519

Q Q Q Q Q Q Q Q Q Q Q

SHELF SUPPORT KIT FOR CONDENSATE TRAP

code 1101529

Q Q Q Q Q Q Q Q Q Q Q

CHIMNEY FRONT COVER KIT

code 1101449

Q Q Q Q Q Q Q Q Q Q Q

Ø 80 FLEXIBLE/FLEXIBLE CONNECTION F/F

code 1101459

Q Q Q Q Q Q Q Q Q Q Q

Ø 80 FLEXIBLE/RIGID CONNECTION F

code 1101539

Q Q Q Q Q Q Q Q Q Q Q

CONDENSATE SYPHON KIT

code 1101499

Q Q Q Q Q Q Q Q Q Q Q

Ø 80 T-CONNECTION (IN ALUMINIUM)

113
Condensing
FLUE OPTIONS

Ø 80 flue range in plastic (PP) for inside-chimney installation, specific for condensing boilers

FLOOR-STANDING BOILERS
Exclusive BOILER GREEN HE

Mynute GREEN 50 R.S.I.


WALL-HUNG BOILERS

Mynute BOILER GREEN


Exclusive GREEN E

Tower GREEN HE
Mynute Sinthesi
Mynute GREEN

Quadra GREEN
Ciao GREEN
MySMART

Ciao AT
code 1101359

Q Q Q Q Q Q Q Q Q Q Q

Ø 60/100 CHIMNEY ADAPTER

code 1101379

Q Q Q Q Q Q Q Q Q Q Q

Ø 60/80 ADAPTER

code 1101429

Q Q Q Q Q Q Q Q Q Q Q

Ø 80 FLEXIBLE EXTENSION (12.5 m) with 8 SPACERS

code 1101439

Q Q Q Q Q Q Q Q Q Q Q

Ø 80 RIGID/FLEXIBLE CONNECTION M

code 1101509

Q Q Q Q Q Q Q Q Q Q Q
Ø 80 CONDENSATE TRAP CAP FOR
T-CONNECTION (IN ALUMINIUM)

114
Condensing
FLUE OPTIONS

Ø 50 flue range in PPs (H1 Class) for inside-chimney installation, specific for condensing boilers

FLOOR-STANDING BOILERS
Exclusive BOILER GREEN HE

Mynute GREEN 50 R.S.I.


WALL-HUNG BOILERS

Mynute BOILER GREEN


Exclusive GREEN E

Tower GREEN HE
Mynute Sinthesi
Mynute GREEN

Quadra GREEN
Ciao GREEN
MySMART

Ciao AT
code 20031841

Ø 50 45°BEND

code 20031840

Ø 50 90°BEND

ACCESSORIES
FLUES AND
code 20021607

Ø 50 EXTENSION 250 mm

code 20021608

Ø 50 EXTENSION 500 mm

code 20021609

Ø 50 EXTENSION 1000 mm

code * Ø60
Ø50

Q
Ø60
Ø80

Ø60

Ø 80-50 CHIMNEY CONNECTION KIT WITH 90° BEND Ø 50

* to purchase this flue kit please contact the International After Sales Dept.

115
Standard-efficiency
FLUE OPTIONS

Ø 80 twin flue system in aluminium for standard-efficiency boilers

Mynute S 24-28 C.S.I./R.S.I.

Mynute S 35 C.S.I./R.S.I.
WALL-HUNG BOILERS

Exclusive C.S.I./R.S.I.

Ciao S C.S.I./R.S.I.

WATER-HEATERS
Ciao 20-24 C.S.I.
Quadra II C.S.I.

Ciao 28 C.S.I.

Idrabagno ESI
Mynute Boiler
code 1220409
Q Q Q Q
TWIN SYSTEM KIT

code 20049143

Q Q Q

Ø 80 TWIN SYSTEM KIT


code 20049144

Ø 80 TWIN SYSTEM KIT


code 20058721

TWIN SYSTEM KIT

code 1100549
Q
TWIN SYSTEM KIT

code 1100749
Q Q Q Q Q Q Q Q Q
FLUE ADAPTER KIT from Ø 60/100 to Ø 80-80

code 1100139
Q Q Q Q Q Q Q Q Q
Ø 80 AIR INLET HORIZONTAL TERMINAL

code 1100149
Q Q Q Q Q Q Q Q Q
Ø 80 HORIZONTAL FLUE TERMINAL

code 1100169
Q Q Q Q Q Q Q Q Q
Ø 80 90°BEND WITH GASKET

code 1100159
Q Q Q Q Q Q Q Q Q
Ø 80 45°BEND WITH GASKET

116
Standard-efficiency
FLUE OPTIONS

Ø 80 twin flue system in aluminium for standard-efficiency boilers

Mynute S 24-28 C.S.I./R.S.I.

Mynute S 35 C.S.I./R.S.I.
WALL-HUNG BOILERS

Exclusive C.S.I./R.S.I.

Ciao S C.S.I./R.S.I.

WATER-HEATERS
Ciao 20-24 C.S.I.
Quadra II C.S.I.

Ciao 28 C.S.I.

Idrabagno ESI
Mynute Boiler
code 1100179

Q Q Q Q Q Q Q Q Q

Ø 80 EXTENSION (147 mm) with GASKET


code 1100189

Q Q Q Q Q Q Q Q Q

Ø 80 EXTENSION (500 mm) with GASKET

ACCESSORIES
code 1100199

FLUES AND
Q Q Q Q Q Q Q Q Q

Ø 80 EXTENSION (1000 mm) with GASKET

code 1100209

Q Q Q Q Q Q Q Q Q

Ø 80 EXTENSION (1950 mm) with GASKET

code 20067406
Q Q Q Q Q Q Q Q Q
-
+

Ø 80 AIR REGULATION FLANGE KIT

code 1100589

Q Q Q Q Q Q Q Q

Ø 80 CONDENSATE TRAP HORIZONTAL


code 1100599

Q Q Q Q Q Q Q Q

Ø 80 CONDENSATE TRAP VERTICAL


code 1100229

Q Q Q Q Q Q Q Q Q

Ø 80 SPACERS FOR PIPE (4 pcs. pack)


code 1100219

Q Q Q Q Q Q Q Q Q

Ø 14 FLANGED SOCKET FOR INSPECTION (2 pcs.)


code 20006571

Q Q Q Q
FLUE ADAPTER Ø 60/100 TO Ø 80 FOR
B23/B22 INSTALLATION WITH AIR INLET

117
Standard-efficiency
FLUE OPTIONS

Ø 60/100 concentric flue system in Al/Met for standard-efficiency boilers

Mynute S 24-28 C.S.I./R.S.I.

Mynute S 35 C.S.I./R.S.I.
WALL-HUNG BOILERS

Exclusive C.S.I./R.S.I.

Ciao S C.S.I./R.S.I.

WATER-HEATERS
Ciao 20-24 C.S.I.
Quadra II C.S.I.

Ciao 28 C.S.I.

Idrabagno ESI
Mynute Boiler
code 1100029

Q Q Q Q Q Q Q Q Q
Ø 60/100 VERTICAL TERMINAL;
Ø 125 EXTERNAL STRAIGHT PIPE

code 20066976

Q Q Q Q Q Q Q Q Q

Ø 60/100 HORIZONTAL TERMINAL

code 1100079

Q Q Q Q Q Q Q Q Q
Ø 60/100 TELESCOPIC HORIZONTAL TERMINAL
EXTENSIBLE FROM 500 TO 800 mm

code 1100039

Q Q Q Q Q Q Q Q Q

Ø 60/100 CONCENTRIC EXTENSION (750 mm)

code 1100049

Q Q Q Q Q Q Q Q Q

Ø 60/100 CONCENTRIC EXTENSION (1470 mm)

code 20006596*
Q Q Q
* *
90° Ø 60/100 BEND KIT FOR REPLACEMENT

code 1100089

Q Q Q Q Q Q Q Q Q

90° Ø 60/100 CONCENTRIC BEND

code 1100099

Q Q Q Q Q Q Q Q Q

45° Ø 60/100 CONCENTRIC BEND

code 1100119

Q Q Q Q Q Q Q Q Q

Ø 100 CONNECTION CLIP KIT H 80 mm (4 pcs.)

* To be used in case of replacement of old Mynute 24 C.S.I with CIAO S range and with CIAO 24 C.S.I. E, only in case of concentric flue through wall.

118
Standard-efficiency
FLUE OPTIONS

Ø 60/100 concentric flue system in Al/Met for standard-efficiency boilers

Mynute S 24-28 C.S.I./R.S.I.

Mynute S 35 C.S.I./R.S.I.
WALL-HUNG BOILERS

Exclusive C.S.I./R.S.I.

Ciao S C.S.I./R.S.I.

WATER-HEATERS
Ciao 20-24 C.S.I.
Quadra II C.S.I.

Ciao 28 C.S.I.

Idrabagno ESI
Mynute Boiler
code 1100109

Q Q Q Q Q Q Q Q Q

Ø 60/100 CONNECTION CLIP KIT BOILER-FLUE

code 1220189

Q Q Q Q Q Q Q Q Q

Ø 125 PITCHED ROOF TILE FOR VERTICAL FLUE

ACCESSORIES
FLUES AND
code 1220289

Q Q Q Q Q Q Q Q Q

Ø 125 FLAT ROOF TILE FOR VERTICAL FLUE

code 1100579

Q Q Q Q Q Q Q Q

Ø 60/100 CONDENSATE TRAP HORIZONTAL

code 1220029

Q Q Q Q Q Q Q Q

Ø 60/100 CONDENSATE TRAP VERTICAL

code 1220199

Q Q Q Q Q Q Q Q Q

Ø 100 SPACERS FOR PIPE (4 pcs. pack)

code 1100009

Q Q Q Q Q Q Q Q Q
Ø 14 FLANGED SOCKET FOR INSPECTION
FOR CONCENTRIC PIPE (2 pcs.)

119
Standard-efficiency
FLUE OPTIONS

Ø 60/100 concentric flue system in Al/PPu for standard-efficiency boilers

Mynute S 24-28 C.S.I./R.S.I.

Mynute S 35 C.S.I./R.S.I.
WALL-HUNG BOILERS

WALL-HUNG BOILERS
Exclusive C.S.I./R.S.I.

Ciao S C.S.I./R.S.I.

Ciao 20-24 C.S.I.

Ciao 28 C.S.I.

Idrabagno ESI
Mynute Boiler
Quadra II
code 20066975

Q Q Q Q Q Q Q Q Q
Ø 60/100 VERTICAL FLUE TERMINAL;
Ø 125 EXTERNAL STRAIGHT PIPE

code 20066976

Q Q Q Q Q Q Q Q Q

Ø 60/100 CONCENTRIC HORIZONTAL TERMINAL

code 20066977

Q Q Q Q Q Q Q Q Q
Ø 60/100 TELESCOPIC HORIZONTAL TERMINAL
EXTENSIBLE FROM 500 mm TO 800 mm

code 20066970

Q Q Q Q Q Q Q Q Q

Ø 60/100 CONCENTRIC EXTENSION 500 mm

code 20066971

Q Q Q Q Q Q Q Q Q

Ø 60/100 CONCENTRIC EXTENSION 1000 mm

code 20066972

Q Q Q Q Q Q Q Q Q

Ø 60/100 CONCENTRIC EXTENSION 2000 mm

code 20066966

Q Q Q Q Q Q Q Q Q

90° Ø 60/100 CONCENTRIC BEND

code 20066964

Q Q Q Q Q Q Q Q Q

45° Ø 60/100 CONCENTRIC BEND

120
Standard-efficiency
FLUE OPTIONS

Ø 60/100 concentric flue system in Al/PPu for standard-efficiency boilers

Mynute S 24-28 C.S.I./R.S.I.

Mynute S 35 C.S.I./R.S.I.
WALL-HUNG BOILERS

WALL-HUNG BOILERS
Exclusive C.S.I./R.S.I.

Ciao S C.S.I./R.S.I.

Ciao 20-24 C.S.I.

Ciao 28 C.S.I.

Idrabagno ESI
Mynute Boiler
Quadra II
code 20066967

Q Q Q Q Q Q Q Q Q
90° Ø 60/100 CONCENTRIC BEND
- FOR BOILER CONNECTION

code 20066968

Q Q Q Q Q Q Q Q Q
90° Ø 60/100 CONCENTRIC BEND
WITH INSPECTION DOOR

ACCESSORIES
FLUES AND
code 20066969

Q Q Q Q Q Q Q Q Q
90° Ø 60/100 CONCENTRIC BEND WITH
INSPECTION DOOR - FOR BOILER CONNECTION

code 1220189

Q Q Q Q Q Q Q Q Q

Ø 125 PITCHED ROOF TILE FOR VERTICAL FLUE

code 1220289

Q Q Q Q Q Q Q Q Q

Ø 125 FLAT ROOF TILE FOR VERTICAL FLUE

code 1220199

Q Q Q Q Q Q Q Q Q

Ø 100 SPACERS FOR PIPE (4 pcs. pack)

121
Standard-efficiency
FLUE OPTIONS

Ø 80/125 concentric flue system in Al/Met for standard-efficiency boilers

Mynute S 24-28 C.S.I./R.S.I.

Mynute S 35 C.S.I./R.S.I.
WALL-HUNG BOILERS

Exclusive C.S.I./R.S.I.

Ciao S C.S.I./R.S.I.

Ciao 20-24 C.S.I.

Ciao 28 C.S.I.

Mynute Boiler
Quadra II
code 1103129

Q Q Q Q Q Q
Ø 60/100 FLUE ADAPTER FROM TO
Ø 80/125 WITH FLUE ANALYSIS POINT

code 1103139

Q Q Q Q Q Q

45° Ø 80/125 CONCENTRIC BEND

code 1103149

Q Q Q Q Q Q

90° Ø 80/125 CONCENTRIC BEND

code 1103159

Q Q Q Q Q Q
Ø 80/125 HORIZONTAL TERMINAL
WITH Ø 60/100 ADAPTER

code 1103169

Q Q Q Q Q Q
Ø 80/125 VERTICAL TERMINAL
WITH Ø 60/100 ADAPTER

code 1103179

Q Q Q Q Q Q

Ø 80/125 CONCENTRIC EXTENSION 500 mm

122
Standard-efficiency
FLUE OPTIONS

Ø 80/125 concentric flue system in Al/Met for standard-efficiency boilers

Mynute S 24-28 C.S.I./R.S.I.

Mynute S 35 C.S.I./R.S.I.
WALL-HUNG BOILERS

Exclusive C.S.I./R.S.I.

Ciao S C.S.I./R.S.I.

Ciao 20-24 C.S.I.

Ciao 28 C.S.I.

Mynute Boiler
Quadra II
code 1103189

Q Q Q Q Q Q

Ø 80/125 CONCENTRIC EXTENSION 1000 mm

code 1103199

Q Q Q Q Q Q

Ø 80/125 CONCENTRIC EXTENSION 2000 mm

ACCESSORIES
FLUES AND
code 1103209

Q Q Q Q Q Q

SYPHON FOR VERTICAL ADAPTER

code 1100059

Q Q Q Q Q Q

Ø 125 FLAT ROOF TILE FOR VERTICAL FLUE

code 1100069

Q Q Q Q Q Q

Ø 125 PITCHED ROOF TILE FOR VERTICAL FLUE

code 1101689

Q Q Q Q Q Q

Ø 80/125 SPACERS (5 pcs.)

123
Accessories for boilers
COMFORT ACCESSORIES

This page contains only some of Beretta accessories, in order to better illustrate them when useful. For the matching of the accessories with the
boilers, please consult each boiler page.

CODE DESCRIPTION

1100799 Outdoor probe

20049748 Outdoor probe with connector

20008401 Connector kit for outdoor probe and remote control

1221179 OTBus interface board

ITRF05 electronic board to control the main heating zone to be used


20000783
with remote control or supplementary heating pump (only AKL pcb)

20062614 BE09 interface for alarm remotation

BE08 electronic board to control the main heating


1103039
zone (to be used with remote control)

124
Accessories for boilers
HYDRAULIC ACCESSORIES

This page contains only some of Beretta accessories, in order to better illustrate them when useful. For the matching of the accessories with the
boilers, please consult each boiler page.

CODE DESCRIPTION

20008794 Kit hydraulic connections (for welding)

20051979
Kit hydraulic connections (with brass nipples)
20008795

ACCESSORIES
1101989 Heating taps

FLUES AND
1101999 Heating taps with filter

20032815 A-Class Low Energy synchronous pump, PWM controlled (7 metres)

1220599 Socket probe for DHW tank 3 m wire (R.A.I and R.S.I. models)

20025113 Solar diverter valve kit (including flexible stainless steel connection pipes) )

1100509 Gas tap ¾” right-angle

125
Accessories for boilers
SPECIAL ACCESSORIES

This page contains only some of Beretta accessories, in order to better illustrate them when useful. For the matching of the accessories with the
boilers, please consult each boiler page.

CODE DESCRIPTION

20042454 Kit relé remote alarm

1220639 Low temperature automatic resetting thermostat

20012595 Upper cover

20012594 Lower cover

20051629 Lower cover

126
COMPLEMENTARY
ITEMS

COMPLEMENTARY
ITEMS

127
Hydraulic separators - with vertical separator and direct zones
CONNECT LE

Can be matched with all Beretta condensing and standard-efficiency


wall-hung and floor-standing boilers.
Low Energy auto-modulating pumps (EEI≤0,20).
Limit thermostat for low temperature installations supplied as standard.
Specifically designed only for in-box installations (INDOOR and
OUTOOR).
IPX4D electrical protection.
Possibility to connect the zones thermostats.

Connect LE - Low Energy with direct zones

DIMENSIONS
CODE MODEL ZONES HxWxD
(mm)

1 direct zone
20083968 CONNECT LOW ENERGY 1D LE (*) see BOX
(high head)

20083969 CONNECT LOW ENERGY 2D LE (*) 2 direct zones see BOX

20083970 CONNECT LOW ENERGY 3D LE (*) 3 direct zones see BOX

(*) For the installation it is neccessary to purchase the BOX (code 20007305)

Box for Connect


DIMENSIONS
CODE DESCRIPTION HxWxD
(mm)

20007305 BOX for CONNECT 720 x 400 x 160

128
Hydraulic separators - with vertical separator and direct zones
CONNECT LE

Accessories

CODE DESCRIPTION

20085456 insulation kit CONNECT LE (*)


1221179 OTBus interface board for EXCLUSIVE GREEN e and EXCLUSIVE BOILER GREEN he
(*) To be installed before introducing the CONNECT into the BOX.

Connect LE with direct zones


Residual head available to the system Residual head available to the system
for CONNECT 1D LE for CONNECT 3D LE / CONNECT 2D LE

8 8
7 7 CC4
6 6 CC3
PP3

COMPLEMENTARY
5 CP3 5 CC2
Circulator head (m)

Circulator head (m)

ITEMS
4 4 CP3
3
PP CP2 CC1
3 3
CP2
PP2 PP1
2 CP1 2 PP2 PP1
CC
C C 4 CP1
1 CC1 C2 C3 1
0 0

Flow rate (m3/h) Flow rate (m3/h)

PP1 LOW proportional head curve CC1 Curve 1 = 4 metres


PP2 AVERAGE proportional head curve CC2 Curve 2 = 5 metres
PP3 HIGH proportional head curve CC3 Curve 3 = 6 metres
CC4 Curve 4 MAX = 7 metres
CP1 LOW constant head curve
CP2 AVERAGE constant head curve
CP3 HIGH constant head curve

129
Hydraulic separators - with vertical separator and motorized mixed zones
CONNECT LE

Can be matched with all Beretta condensing and standard-efficiency


wall-hung and floor-standing boilers.
Low Energy auto-modulating pumps (EEI≤0,20).
3-ways motorized mixing valve.
Independent climatic bends setting for each zone.
Electronic management board supplied as standard.
Limit thermostat for low temperature installations supplied as standard.
Specifically designed only for in-box installations (INDOOR and
OUTOOR).
IPX4D electrical protection.
Possibility to connect the zones thermostats.

Connect LE - Low Energy with motorized mixed zones

DIMENSIONS
CODE MODEL ZONES HxWxD
(mm)

20083971 CONNECT LOW ENERGY AT/BT LE (*) 1AT+1BT see BOX

20083972 CONNECT LOW ENERGY AT/2BT LE (*) 1AT+2BT see BOX

(*) For the installation it is neccessary to purchase the BOX (code 20007305)

Box for Connect


DIMENSIONS
CODE DESCRIPTION HxWxD
(mm)

20007305 BOX for CONNECT 720 x 400 x 160

130
Hydraulic separators - with vertical separator and motorized mixed zones
CONNECT LE

Accessories

CODE DESCRIPTION

20085456 insulation kit CONNECT LE (*)


1221179 OTBus interface board for EXCLUSIVE GREEN e and EXCLUSIVE BOILER GREEN he
(*) To be installed before introducing the CONNECT into the BOX.

Connect LE with mixed zones


Residual head available at Residual head available at
HIGH TEMPERATURE system LOW TEMPERATURE system

8 8
CC4
7 CC4 7
6 CC3 6 CC3

COMPLEMENTARY
Circulator head (m)

PP3 5 CC2
Circulator head (m)

5 CC2 CP3

ITEMS
CP3 4 CC1
4
CC1 PP3 CP2
3 3
CP2 PP2
2 PP2 2 PP1
PP1 CP1
1 CP1 1
0 0

Flow rate (m3/h) Flow rate (m3/h)

PP1 LOW proportional head curve CC1 Curve 1 = 4 metres


PP2 AVERAGE proportional head curve CC2 Curve 2 = 5 metres
PP3 HIGH proportional head curve CC3 Curve 3 = 6 metres
CC4 Curve 4 MAX = 7 metres
CP1 LOW constant head curve
CP2 AVERAGE constant head curve
CP3 HIGH constant head curve

131
Hydraulic separators - with vertical separator and thermostatic mixed zones
CONNECT BASE LE

Can be matched with all Beretta condensing and standard-efficiency


wall-hung and floor-standing boilers.
Thermostatic mixing valve on BT zones.
Low Energy auto-modulating pumps (EEI≤0,20).
Limit thermostat for low temperature installations supplied as standard.
Specifically designed only for in-box installations (INDOOR and
OUTOOR).
IPX4D electrical protection.

Connect BASE LE - Low Energy with thermostatic BT zones


DIMENSIONS
CODE MODEL HxWxD
(mm)

20084765 CONNECT BASE LE MIX1 1AT+1BT (thermostatic) (*) see BOX

20084766 CONNECT BASE LE MIX2 1AT+2BT (thermostatic) (*) see BOX

(*) For the installation it is neccessary to purchase the BOX (code 20007305)

Box for Connect


DIMENSIONS
CODE DESCRIPTION HxWxD
(mm)

20007305 BOX for CONNECT (for installation) 720 x 400 x 160

132
Hydraulic separators - with vertical separator and thermostatic mixed zones
CONNECT BASE LE

Accessories

CODICE DESCRIPTION

20085456 Insulation kit for CONNECT LE (*)


(*) To be installed before introducing the CONNECT into the BOX.

Connect Base LE - Low Energy

Residual head available at Residual head available at


HIGH TEMPERATURE system LOW TEMPERATURE system

8 8
CC4
7 CC4 7

COMPLEMENTARY
CC3
6 CC3 6
Circulator head (m)

3
Circulator head (m)

ITEMS
PP CC2
5 CC2 5
CP3
4 CP3 4
CC1 PP3
3 3 CP2 CC
CP2 PP2 1
2 PP2 2
PP1
CP1
1 1
CP1 PP1
0 0
0 0,5 1 1,5 2 2,5 3 0 0,2 0,4 0,6 0,8 1 1,2 1,4 1,6 1,8
Flow rate (m3/h) Flow rate (m3/h)

PP1 LOW proportional head curve CC1 Curve 1 = 4 metres


PP2 AVERAGE proportional head curve CC2 Curve 2 = 5 metres
PP3 HIGH proportional head curve CC3 Curve 3 = 6 metres
CC4 Curve 4 MAX = 7 metres
CP1 LOW constant head curve
CP2 AVERAGE constant head curve
CP3 HIGH constant head curve

133
Hydraulic separators - with horizontal separator
CONNECT AT/BT LE

To be matched only with Beretta condensing boilers Exclusive Green e


and Exclusive Boiler Green he.
3-ways motorized mixing valve.
Low Energy auto-modulating pumps (EEI≤0,20).
Independent climatic bends setting for each zone.
Electronic management board supplied as standard.
Limit thermostat for low temperature installations supplied as standard.
Specifically designed only for in-box installations (INDOOR and
OUTOOR).
IPX4D electrical protection.
Box supplied as standard.

Connect LE - Low energy


DIMENSIONS
CODE MODEL HxWxD
(mm)

20094267 CONNECT AT/BT LE (BT with motorized mixing valve) 616 x 440 x 155

134
DHW tanks for wall-hung boilers
IDRA BV

Enamelled DHW tank, ideal to be matched with Beretta wall-hung


boilers R.A.I./R.S.I. (‘only heating’ models).
Supplied with high thermal-exchange coil.
Wide range to meet all DHW needs.
Magnesium anode supplied as standard.
Double magnesium anode supplied as standard on BV 1000 model.

Single coil DHW tank


DIMENSIONS DHW TANK HEAT ENERGY CLASS
CODE MODEL HxØ CAPACITY LOSS
(mm) (litres) (W)

210
20101895 IDRA BV 200 1330x605
(enamelled)
59 F

COMPLEMENTARY
304
20101897 IDRA BV 300 1830x605 69 F

ITEMS
(enamelled)
444
20101899 IDRA BV 430 1630x755
(enamelled)
83 F
556
20101900 IDRA BV 550 1980x755 96 -
(enamelled)
735
20101901 IDRA BV 800 1835x1000 135,5 -
(enamelled)
890
20101902 IDRA BV 1000 2165x1000 142,5 -
(enamelled)

Accessories

CODE DESCRIPTION

1220599 Socket probe for DHW tank


1150529 ¾” Mixing valve
20001492 1” Mixing valve (with ¾” adapter)
1150489 DHW expansion vessel 18 litres
1150509 DHW expansion vessel 24 litres
1150519 DHW expansion vessel 35 litres

135
DHW tanks for wall-hung boilers
BV 120

Enamelled DHW tank, ideal to be matched with Beretta wall-hung


boilers R.A.I./R.S.I. (‘only heating’ models).
Supplied with high thermal-exchange coil.
Magnesium anode supplied as standard.
DHW safety-valve supplied as standard.
DHW expansion vessel available as optional.
DHW connections and filling tap kit available as optional.
Control board with thermostat available as optional.

Single coil DHW tank

DIMENSIONS DHW TANK HEAT ENERGY CLASS


CODE MODEL HXØ CAPACITY LOSS
(mm) (litres) (W)

115
20050723 BV 120 750 x 560 69
(enamelled)
150
20050725 BV 160 950 x 560 76
(enamelled)

Specific accessories

CODE DESCRIPTION

1220599* Socket probe for DHW tank


20050731* DHW expansion vessel 4 litres
20050732* DHW connections and filling tap kit
20053293 Control board kit with thermostat
696109 Vertical hydraulic connection
696119 Remote hydraulic connection
* Beretta recommended accessories with BV tanks.

136
DHW tanks for wall-hung boilers
IDRA M 60

Stailess-steel DHW tank, capacity 60 litres, ideal to be matched with


the wall-hung boilers R.S.I and R.A.I. (‘only heating’ models).
Designed for wall-hung installation.
Supplied with high thermal transfer coil.
Magnesium anode supplied as standard.
Tank probe supplied as standard.

According to the European Directive ErP, the following product are not allowed
DHW tanks to be placed on the European market by manufacturer since 01/08/2015

DIMENSIONS DHW TANK


CODE MODEL HxWxD CAPACITY
(mm) (litres)

60
1150319 IDRA M 60 925 x 450 x 360
(stainless steel)

COMPLEMENTARY
ITEMS
Specific accessories

CODE DESCRIPTION

1150329 DHW expansion vessel kit


1103479 DHW recirculation kit
20025113 Solar diverter valve (including flexible stainless steel connection pipes)

137
Hydraulic devices
SOLAR DIVERTER VALVE

Can be used with instantaneous combi boilers.


Suitable for DHW pre-heated by solar collectors.
Selectable temperature (from 30 °C to 56 °C).
Fixing brackets and gaskets supplied as standard.

Hydraulic accessories

CODE DESCRIPTION

20025113 Solar diverter valve kit (including flexible stainless steel connection pipes)
20035644 Solar diverter valve

138
Hydraulic devices
SOLAR DIVERTER VALVE

The following diagram shows the application of Beretta solar diverter valve in a natural circolation system.

Natural circulation solar system with integration combi boiler

key:
1 - natural circulation system
2 - condensing combi boiler
3 - DHW solar diverter valve

COMPLEMENTARY
ITEMS
3

DHW
DCW

this system diagram has only an indication purpose

139
Devices for the systems management
CONTROL SYSTEM V3

Management of cascade, system and solar thermal.


Management of cascades up to 8 boilers.
Management of 2 zones.
Management of solar thermal.
Can be installaed in the plant room.
Remote control function.
Operation mode display.
Can be matched with external temperature probe for the activation of
climatic thermoregulation.

Management of systems without heat pump

CODE DESCRIPTION

CONTROL SYSTEM V3
20028618 for cascade and solar thermal
(MERLIN V3)

Accessories

CODE DESCRIPTION

20084652 Advanced programmable room thermostat

20084654 Room thermostat

20084656 Control box for management of 2 additional zones

20028617 Interface board kit for 1 boiler

4043014 External probe kit

4043013 Zones/tank probe kit

20008787 Solar probe kit

140
Devices for the systems management
CONTROL SYSTEM V4

Management of cascade, system, solar thermal and heat pump.


Management of cascades up to 8 boilers.
Management of 2 zones.
Management of solar thermal.
Management of 4 heat pumps in cascade configuration.
Can be installaed in the plant room.
Integrated and detachable room thermostat.
Operation mode display.
Can be matched with external temperature probe for the activation of
climatic thermoregulation.

Management of systems with heat pump

CODE DESCRIPTION

CONTROL SYSTEM V4
20069782 for cascade, solar thermal and heat pump
(MERLIN V4)

Accessories

COMPLEMENTARY
ITEMS
CODE DESCRIPTION

20084652 Advanced programmable room thermostat

20084654 Room thermostat

20084656 Control box for management of 2 additional zones

20028617 Interface board kit for 1 boiler

4043014 External probe kit

4043013 Zones/tank probe kit

20008787 Solar probe kit

141
Programmable digital room thermostat
ALPHA 7D/ALPHA 7D WIRELESS

7-day programmable room thermostat (in 60-minutes steps).


Built-in heating programme.
3°C ÷ 35°C selectable temperature range with 0,2°C increments.
4 modes of operation: auto, advance, off, party.
3-temperature selections – comfort, economy, frost.
Display boiler ‘ON’.
Selectable ON/OFF hysteresis.
Low battery indicator.
Summer function for cooling mode (separator relay needed)
Included in the package: 1,5V batteries (type AAA), screws and wall
plugs, double side adhesive

Additional features on Alpha 7D Wireless


Wireless for a flexible installation (pre-cabled).
40-metre range.
Receiver can be mounted to wall (screws and plugs included) or
mounted to the side of the boiler (magnetic strips included).

7-day programmable room thermostat


DIMENSIONS
CLASS ErP
CODE MODEL TYPE HxWxD
CONTRIBUTION
(mm)

20063872 ALPHA 7D 7-day digital room-thermostat I - 1% 86 × 86 × 20

20101748 ALPHA 7D WIRELESS 7-day digital room-thermostat wireless I - 1% 86 × 86 × 20

142
Digital room thermostat
ALPHA DGT/ALPHA DGT WIRELESS

Digital room thermostat.


5°C ÷ 35°C selectable temperature range with 0,2°C increments.
Easy to read digital display.
Tactile and easy to rotate selector dial.
Simple installation.
Selectable ON/OFF hysteresis.
Included in the package: 1,5V batteries (type AAA), screws and wall
plugs, double side adhesive

Additional features on Alpha DGT Wireless


Wireless for a flexible installation (pre-cabled).
40-metre range.
Receiver can be mounted to wall (screws and plugs included) or
mounted to the side of the boiler (magnetic strips included).

Digital room thermostat


DIMENSIONS
CLASS ErP
CODE MODEL TYPE HxWxD
CONTRIBUTION

COMPLEMENTARY
(mm)

ITEMS
20059639 ALPHA DGT Digital room-thermostat I - 1% 86 × 86 × 20

20059641 ALPHA DGT WIRELESS Digital room-thermostat wireless I - 1% 86 × 86 × 20

143
144
MODULAR CONDENSING
BOILERS

MODULAR CONDENSING
BOILERS

145
Modular wall-hung boilers for light commercial applications up to 200 kW
MYNUTE GREEN 50 R.S.I.
Ŷ MYNUTE GREEN 50 R.S.I. is a high power condensing boiler, that
INTERAXES AND HYDRAULIC
FITTINGS POSITIONING
can be configurated in different ways, according to your needs.
CH Cond Gas CH Ŷ Available a full cascade system up to 200 kW. The different
R C G F cascade configurations are illustrated in the following pages.
48 230 107 Ŷ On ErP model: Low Energy, A-Class, synchronous pump
(EEI ≤ 0.23).
Ŷ The RANGE RATED certification allows to adapt the power of the boiler
to the real thermal requests of the installation.
Ŷ Efficiency ++++ according to European Directive EEC 92/42.
Ŷ Low NOx (Class 5 according to European Directive UNI EN 483) the
best European category in ecological terms, helping to safeguard the
environment.
Ŷ Condensing heat exchanger in extruded aluminium with radial design
that allows to get the most from the combustion of the gas, whether
NG or LPG.
Ŷ Built-in connection port OT-bus protocol for intelligent cascade control.
Ŷ Built-in interface board for second pump control.
Ŷ LPG conversion kit available as an accessory.

For the stand-alone configurations of


Mynute GREEN 50, see the “condensing boilers”
section in this catalogue.

Premix room-sealed condensing

DIMENSIONS CH INPUT DHW ENERGY CLASS


CODE GAS MODEL H ×W × D MIN - MAX PRODUCTION
(mm) (kW) (l/min. - Δt 25 °C)    

HEATING ONLY BOILER


MYNUTE GREEN
20100121 NG
50 R.S.I.
764 × 553 × 284 9.00 - 47.00 -      -

According to the European Directive ERP, the following products are not allowed
Premix room-sealed condensing to be placed on the European market by the manufacturer since 01/08/2015

DIMENSIONS CH INPUT DHW


CODE GAS MODEL H ×W × D MIN - MAX PRODUCTION
(mm) (kW) (l/min. - Δt 25 °C)

HEATING ONLY BOILER


MYNUTE GREEN
20056275 NG 764 × 553 × 284 9.00 - 47.00 -
50 R.S.I.

146
Modular wall-hung boilers for light commercial applications up to 200 kW
MYNUTE GREEN 50 R.S.I.

Technical specifications

MYNUTE GREEN 50 RSI


DESCRIPTION single 100 kW 150 kW 200 kW
application cascade cascade cascade
CH nominal heat input kW 47 94 141 188
CH nominal heat output (80°-60°C) kW 45,78 91,56 137,34 183,12
CH nominal heat output (50°-30°C) kW 49,91 99,82 149,73 199,64
CH minimum heat input kW 9 9 9 9
CH minimum heat output (80°-60°C) kW 8,78 8,78 8,78 8,78
CH minimum heat output (50°-30°C) kW 9,72 9,72 9,72 9,72
Efficiency class according European
++++
Directive EEC 92/42
Efficiency at max nominal output (80°-60°C) % 97,40 97,40 97,40 97,40
Efficiency at min output (80°-60°C) % 97,60 97,60 97,60 97,60
Efficiency at partial load 30% (47°C return) % 102,50 102,50 102,50 102,50
Efficiency at max nominal output (50°-30°C) % 106,20 106,20 106,20 106,20
Efficiency at min output (50°-30°C) % 108 108 108 108
Efficiency at partial load 30% (30°C return) % 108 108 108 108
Max power consumption / ERP boiler W 121 242 363 484
Max power consumption / non-ERP boiler W 164 328 492 656
Central heating
Maximum pressure - temperature bar - °C 4 - 90 4 - 90 4 - 90 4 - 90
Minimum pressure for standard operation bar 0,25÷0,45 0,25÷0,45 0,25÷0,45 0,25÷0,45
Adjustable CH water temperature range °C 20÷80 20÷80 20÷80 20÷80

MODULAR CONDENSING
BOILERS

147
Modular wall-hung boilers for light commercial applications up to 200 kW
MYNUTE GREEN 50 R.S.I. - linear free-standing cascade applications

By means of the following components, Mynute GREEN 50 R.S.I. can be cascaded in linear free-standing configurations, as illustrated
in the following pages. 405.6

331.4
2743

594 653 653 134.7


72

273.6

763
553 100 553 100 553 523.5

2136 (second boiler)

2170 (third boiler)


2101 (first boiler)

2242
126.5

1793
78
125

991
250

718
468
62
368

229.5

380.5

424
Example of linear free-standing cascade configuration (150 kW) with dimensions.
770

Hydraulic accessories and safety devices – linear cascade applications

CODE DESCRIPTION CODE DESCRIPTION

20043895 Gas-safety cut-off valve 20047606 * Rear mounting kit - 1 MYNUTE GREEN 50 R.S.I.
20060671 Hydraulic header/separator kit for cascade applications 20047607 * Rear mounting kit - 2 MYNUTE GREEN 50 R.S.I.
Hydraulic collectors kit for linear 20060670 I.N.A.I.L. hydraulic manifold for cascade applications
20028623
cascade applications - 1 boiler
20060669 I.N.A.I.L. safety kit
20046101 Support rig for 1 MYNUTE GREEN 50 R.S.I.
20046100 Support rig for 2 MYNUTE GREEN 50 R.S.I. * To be used only in case of free-standing cascade applications (when
the support rig is not fixed to the wall).

Electrical accessories and interfaces – cascade applications

CODE DESCRIPTION CODE DESCRIPTION

20028618 Control kit for cascade/solar system 4043013 Probe kit zones/DHW tank for cascade applications
20028617 Interface board for cascade application - 1 boiler 20008787 Solar probe kit for cascade applications
1220639 Limit thermostat for low temperature applications 20039196 CO safety sensor for boiler room
4043014 External probe kit for cascade applications

Flue accessories – linear cascade applications

CODE DESCRIPTION CODE DESCRIPTION

20028478 Air-inlet kit for B23 Flues collector kit for linear cascade
20028625
applications - 3rd boiler
Flues collector kit Ø 125 for linear
20028616
cascade applications - 2nd boiler

148
Modular wall-hung boilers for light commercial applications up to 200 kW
MYNUTE GREEN 50 R.S.I. - linear free-standing cascade applications

In linear free standing applications, cascades can reach max 150 kW, as illustrated in the following configurations.
To define the cascade system according to your needs, please contact the Beretta International pre-sales dept. for support.

100 kW linear free-standing cascade configuration *

CODE DESCRIPTION Q.TY


20100121 MYNUTE GREEN 50 R.S.I. 2
20043895 Gas-safety cut-off valve 1
20060671 Hydraulic header/separator kit for cascade applications 1
20028623 Hydraulic collectors kit for linear cascade applications - 1 boiler 2
20028616 Flues collector kit Ø 125 for linear cascade applications - 2 boilers 1
20028478 Air-inlet kit for B23 2
20028617 Interface board for cascade applications - 1 boiler 2
20028618 Control kit for cascade-solar system 1
4043014 External probe kit for cascade applications 1
20046100** Support rig for 2 MYNUTE GREEN 50 R.S.I. 1
20060670*** I.N.A.I.L. hydraulic manifold for cascade application 1
20060669*** I.N.A.I.L. safety kit 1

150 kW linear free-standing cascade configuration *

CODE DESCRIPTION Q.TY


20100121 MYNUTE GREEN 50 R.S.I. 3
20043895 Gas-safety cut-off valve 1
20060671 Hydraulic header/separator kit for cascade applications 1

MODULAR CONDENSING
20028623 Hydraulic collectors kit for linear cascade applications - 1 boiler 3

BOILERS
20028616 Flues collector kit Ø 125 for linear cascade applications - 2 boilers 1
20028478 Air-inlet kit for B23 3
20028625 Flues collector kit Ø 125 for linear cascade applications - third boiler 1
20028617 Interface board for cascade applications - 1 boiler 3
20028618 Control kit for cascade-solar system 1
4043014 External probe kit for cascade applications 1
20046101** Support rig for 1 MYNUTE GREEN 50 R.S.I. 1
20046100** Support rig for 2 MYNUTE GREEN 50 R.S.I. 1
20060670*** I.N.A.I.L. hydraulic manifold for cascade application 1
20060669*** I.N.A.I.L. safety kit 1

* In case of MYNUTE GREEN 50 R.S.I. cascade applications it is strongly recommended to use CO safety-sensor for boiler room (code 20039196).
** The support rig must be fixed to the wall. In case it is not possible to fix it to the wall, the rear mounting kit for back-to back cascade - 1 MYNUTE
GREEN 50 R.S.I. (code 20047606) and the rear mounting kit for back-to back cascade - 2 MYNUTE GREEN 50 R.S.I. (code 20047607) must be
used in addition.
*** Optional component. “I.N.A.I.L.” is an Italian Safety Certification Institute. Beretta highly recommends safety devices also in countries where they
are not compulsory.

149
Modular wall-hung boilers for light commercial applications up to 200 kW
MYNUTE GREEN 50 R.S.I. - back-to-back cascade applications

By means of the following components, Mynute GREEN 50 R.S.I. can be cascaded in back-to-back configurations, as illustrated in the
following pages.
2094

486 653 440


Ø125
367

621
Ø125
335


65.4

252 553 100 553

763

2163 (2000 kW)


2122 (100 kW)

2235
373

2”M
2”
125

1 1/2”
250

991
1”F 2”M
2”

718
1”M 2”M

468
368

110

Ø32

95

111
262
Example of back-to-back cascade configuration (200 kW) with dimensions. 413

770

Hydraulic accessories and safety devices – back-to-back cascade applications

CODE DESCRIPTION CODE DESCRIPTION

20043895 Gas-safety cut-off valve 20047606 Rear mounting kit - 1 MYNUTE GREEN 50 R.S.I.
20060671 Hydraulic header/separator kit for cascade applications 20047607 Rear mounting kit - 2 MYNUTE GREEN 50 R.S.I.
20060668 Back-to-back hydraulic collectors kit 20060670 I.N.A.I.L. hydraulic manifold for cascade applications
20046101 Support rig for 1 MYNUTE GREEN 50 R.S.I. 20060669 I.N.A.I.L. safety kit
20046100 Support rig for 2 MYNUTE GREEN 50 R.S.I.

Electrical accessories and interfaces – cascade applications

CODE DESCRIPTION CODE DESCRIPTION

20028618 Control kit for cascade/solar system 4043014 External probe kit for cascade applications
20028617 Interface board for cascade application - 1 boiler 4043013 Probe kit zones/DHW tank for cascade applications
20029862 Frost protection kit for condensate syphon 20008787 Solar probe kit for cascade applications
1220639 Limit thermostat for low temperature applications 20039196 CO safety sensor for boiler room

Flue accessories – back-to-back cascade applications

CODE DESCRIPTION CODE DESCRIPTION

Flues collector kit -


20028478 Air-inlet kit for B23 20060930
back-to back cascade/3rd boiler
Flues collector kit Ø 125 - Flues collector kit -
20060916 20060935
back-to back cascade/2nd boiler back-to back cascade/4th boiler

150
Modular wall-hung boilers for light commercial applications up to 200 kW
MYNUTE GREEN 50 R.S.I. - back-to-back cascade applications

In back-to-back free-standing applications, cascades can reach max 200 kW, as illustrated in the following configurations.
To define the cascade system according to your needs, please contact the Beretta International pre-sales dept. for support.

100 kW back-to-back free-standing cascade configuration *

CODE DESCRIPTION Q.TY


20100121 Mynute Green 50 R.S.I. 2
20043895 Gas-safety cut-off valve 1
20060671 Hydraulic header/separator kit for cascade applications 1
20060668 Back-to-back hydraulic collectors kit 1
20060916 Flues collector kit Ø 125 for back-to-back cascade - 2 boilers 1
20028478 Air-inlet kit for B23 2
20028617 Interface board for cascade applications - 1 boiler 2
20028618 Control kit for cascade-solar system 1
4043014 External probe kit for cascade applications 1
20046101 Support rig for 1 Mynute Green 50 R.S.I. 1
20047606 Rear mounting kit for back-to-back cascade - 1 MYNUTE GREEN 50 R.S.I. 1
20060670** I.N.A.I.L. hydraulic manifold for cascade application 1
20060669** I.N.A.I.L. safety kit 1

150 kW back-to-back free-standing cascade configuration *

CODE DESCRIPTION Q.TY


20100121 Mynute Green 50 R.S.I. 3
20043895 Gas-safety cut-off valve 1
20060671 Hydraulic header/separator kit for cascade applications 1

MODULAR CONDENSING
20060668 Back-to-back hydraulic collectors kit 1

BOILERS
20028623 Hydraulic collectors kit for cascade applications - 1 boiler 1
20060916 Flues collector kit Ø 125 for back-to-back cascade - 2 boilers 1
20060930 Flues collector kit for back-to-back cascade - 3rd boiler 1
20028478 Air-inlet kit for B23 3
20028617 Interface board for cascade applications - 1 boiler 3
20028618 Control kit for cascade-solar system 1
4043014 External probe kit for cascade applications 1
20046100 Support rig for 2 Mynute Green 50 R.S.I. 1
20047607 Rear mounting kit for back-to-back cascade - 2 MYNUTE GREEN 50 R.S.I. 1
20060670** I.N.A.I.L. hydraulic manifold for cascade application 1
20060669** I.N.A.I.L. safety kit 1

* In case of MYNUTE GREEN 50 R.S.I. cascade applications it is strongly recommended to use CO safety-sensor for air-inlet (code 20039196).
** Optional component. “I.N.A.I.L.” is an Italian Safety Certification Institute. This code is compulsory only in Italy. Beretta highly recommends safety
devices also in countries where they are not compulsory.

151
Modular wall-hung boilers for light commercial applications up to 200 kW
MYNUTE GREEN 50 R.S.I. – Back-to-back cascade applications

In back-to-back free-standing applications, cascades can reach max 200 kW, as illustrated in the following configurations.

200 kW back-to-back free-standing cascade configuration *

CODE DESCRIPTION Q.TY


20100121 Mynute Green 50 R.S.I. 4
20043895 Gas-safety cut-off valve 1
20060671 Hydraulic header/separator kit for cascade applications 1
20060668 Back-to-back hydraulic collectors kit 2
20060916 Flues collector kit Ø 125 for back-to-back cascade - 2 boilers 1
20060930 Flues collector kit for back-to-back cascade - 3rd boiler 1
20060935 Flues collector kit for back-to-back cascade - 4th boiler 1
20028478 Air-inlet kit for B23 4
20028617 Interface board for cascade applications - 1 boiler 4
20028618 Control kit for cascade-solar system 1
4043014 External probe kit for cascade applications 1
20046100 Support rig for 2 Mynute Green 50 R.S.I. 1
20047607 Rear mounting kit for back-to-back cascade - 2 MYNUTE GREEN 50 R.S.I. 1
20060670** I.N.A.I.L. hydraulic manifold for cascade application 1
20060669** I.N.A.I.L. safety kit 1

*  In case of MYNUTE GREEN 50 R.S.I. cascade applications it is strongly recommended to use CO safety-sensor for air-inlet (code 20039196).
**  Optional component. “I.N.A.I.L.” is an Italian Safety Certification Institute. This code is compulsory only in Italy. Beretta highly recommends safety
devices also in countries where they are not compulsory.

152
Modular wall-hung boilers for commercial applications
POWER PLUS

Ŷ Minimum polluting emissions: class 5 (UNI EN 483).


Ŷ Pre-mix burner: low NOx emissions class 5 (UNI EN 483).
Ŷ Built-in thermoregulation with external probe supplied as standard.
Ŷ Possibility to combine Power Plus boilers in cascade systems
in wall-hung or free-standing installations.
Ŷ Modulating and modular power regulation.
Ŷ Automatic burner ignition sequence reversal.
Ŷ Simultaneous control of three different circuits, each operating
at different temperatures (DHW tank, high-temperature, low-
temperature).
Ŷ Automatic summer/winter reversal.
Ŷ Anti-legionnaires’ disease function (only available with remote control
kit).
Ŷ Availability of a wide range of accessories for complete cascade
configurations.
Ŷ Can be converted to LPG with LPG kit (supplied as standard).

Premix, open flue (room-sealed through special kit) condensing

DIMENSIONS ENERGY CLASS


INPUT INPUT
CODE GAS MODEL H ×W × D
(kW) Hs (kW) Hi
(mm)
HEATING ONLY BOILERS

20019155 NG POWER PLUS 50 M * 1.000 × 600 × 380 50 45

20019201 NG POWER PLUS 100 M DEP ** 1.000 × 600 × 380 77,3 69,7 -

20019200 NG POWER PLUS 100 M *** 1.000 × 600 × 380 100 90 -

MODULAR CONDENSING
20019309 NG POWER PLUS 100 S *** 1.000 × 600 × 380 100 90 -

BOILERS
* The 50 kW model consists of one heat-exchanger unit.
** The 100 kW DEP model consists of two depowered heat-exchanger units.
*** The 100 kW models consist of two heat-exchanger units.
1000

380 M R gas M R gas


600

153
Modular wall-hung boilers for commercial applications
POWER PLUS

Technical specifications
Power Plus Power Plus Power Plus Power Plus
DESCRIPTION
50 M 100 M DEP 100 M 100 S
Fuel G20 - G25 - G2.350 - G27 - G30 - G31
Appliance Category II2ELwLs3B/P - II2H3+ - I2E(S)B
Type of Appliance B23 - B53 - C13x - C33x - C43x - C53x - C63 - C63x - C83
Heat input ref. Hs (min-max) G20 kW 16.3 - 50.0 16.3 - 77.3 16.3 - 100.0 16.3 - 100.0
Heat input ref. Hi (min-max) G20 kW 15.0 - 45.0 15 - 69,6 15.0 - 90.0 15.0 - 90.0
Useful heat output (80/60°C) (min-max) kW 14.8 - 44.2 14.8 - 68.5 14.8 - 88.3 14.8 - 88.3
Useful heat output (50/30°C) (min-max) kW 16.3 - 48.5 16.3 - 75.3 16.3 - 96.8 16.3 - 96.8
Useful efficiency ref. Hi (80-60°C) % 98.2 98.4 98.2 98.2
Useful efficiency ref. Hi (50-30°C) % 107.7 108.2 107.7 107.7
Useful efficiency at ref. Hi 30% (80 - 60°C) % 98.7
Useful efficiency at ref. Hi 30% (50 - 30°C) % 108.7
Losses through the chimney with the burner operating % 1.3
Losses through the chimney with the burner off % 0.1
Losses through the casing (Tm = 70°C) % 0.5
Flue gas temperature °C Return temperature 5°C
CO2 at minimum - maximum G20 % 9.0 - 9.0
CO2 at minimum - maximum G30 - G31 % 10.4 - 10.4
CO without air at minimum - maximum less than mg/kWh 11-91
NOx Class 5
Air flow rate G20 Nm3/h 58.78 88.84 117.56 117.56
Air flow rate G30 - G31 Nm3/h 58.59 90.58 117.18 117.18
Flue gas flow rate G20 Nm3/h 71.04 114.52 142.08 142.08
Flue gas flow rate G30 - G31 Nm3/h 71.76 110.94 143.52 143.52
Flue mass gas flow rate (max - min) G20 gr/s 20.57 - 6.60 31.08 - 6.60 41.14 - 6.60 41.14 - 6.60
Flue mass gas flow rate (max - min) G30 - G31 gr/s 20.52 - 6.85 31.73 - 6.85 41.04 - 6.85 41.04 - 6.85
at min. heat output Pa 50 50 50 50
Residual head of boiler fan without pipes
at max. heat output Pa 560 420 560 560
at min. heat output Pa 40 40 40 40
Residual head of boiler fan downstream from choke*
at max. heat output Pa 490 370 490 490
Minimum operating pressure, central heating bar 0.5
Maximum operating pressure, central heating bar 6
Maximum admissible temperature °C 90
Range of boiler water temperature settings (±3°C) °C 20 - 80
Water content l 5 10 10 10
Power supply V-Hz 230 - 50
Power consumption: only Gas Boiler W 80 154 160 160
Power consumption: Gas Boiler + LOW ENERGY Pump (ErP compliant) W 165 324 330 330
Power consumption: only LOW ENERGY Pump (ErP compliant) W 85 170 170 170
Power consumption: Gas Boiler + LOW ENERGY Pump (non ErP compliant) W 230 - 460 460
Power consumption: only LOW ENERGY Pump (non ErP compliant) W 150 - 300 300
Index of protection IP X0D
Quantity of condensate kg/h 7.2 11.2 14.4 14.4
Noise level at heat output** (min - max) dbA 48.2 - 57.1 49.0 - 58.0 49.0 - 58.9 49.0 - 58.9
Gas capacity (min - max) G20 Sm3/h 1.52 - 4.76 1.52 - 7.37 1.52 - 9.52 1.52 - 9.52
Gas capacity (min - max) G30 kg/h 1.16 - 3.64 1.16 - 5.48 1.16 - 7.28 1.16 - 7.28
Gas capacity (min - max) G31 kg/h 1.14 - 3.57 1.14 - 5.41 1.14 - 7.14 1.14 - 7.14
Dry weight kg 60.0 90.0 90.0 90.0
(*) Measurements obtained using the choke with which the boiler was homologated.
(**) Measurements taken at 1m from the appliance, at a height of 1.5m with background noise of 36.5 dBA.

154
Modular wall-hung boilers for commercial applications
POWER PLUS - linear wall-hung or free-standing applications

Beretta offers in the following pages a wide choice of configurations of Power Plus series, among which you can choose the one that
best meets your requirements.
By matching the codes here below, according to the preferred installation solution and the power you need, Beretta suggests:

8 linear wall-hung or free standing configurations (from 50 to 400 kW)

CODE DESCRIPTION
1102379 Remote control
20009472 Power Plus rig (front mounting)
20009474* Rear mounting kit for Power Plus free-standing rig
20018456 Supports hydraulic manifold kit (without rig) from 150 kW
20017270** I.N.A.I.L. connection pipes kit - 100 kW
20017271 Hydraulic header/separator - 100 kW
20017226 Hydraulic manifold kit 100 kW for P.P. rig with blank end-flange
20009439 Hydraulic manifold kit up to 400 kW for Power Plus rig
20009444 Blank end-flange kit for hydraulic manifold (400 kW)
20075526 LOW ENERGY pump kit (front) for Power Plus rig (ErP compliant)
20009442 Pump kit (front) for Power Plus rig (non ErP compliant)
20009466 Hydraulic header/separator (150 - 200 kW)
20009467 Hydraulic header/separator (250-460 kW)
20009471 Hydraulic manifold (150 - 400 kW)
20009475** I.N.A.I.L. safety kit (400 kW max.)
20009486 Gas safety cut-off valve (115 kW max.)
20009482 Gas safety cut-off valve (230 kW max.)
20009483 Gas safety cut-off valve (580 kW max.)
4030311 Flues collector kit Ø 125 for 50 kW
4030312 Flues collector kit Ø 125 for 100 kW
20062337 Condensate drain kit Ø 125 with end cap

* This component is recommended also for linear free-standing cascade installations to provide extra stability where needed.
** Optional component (I.N.A.I.L. = Italian safety certification Institute). Beretta highly recommends safety devices also in countries where they are not compulsory.
The whole range of accessories and flues for POWER PLUS applications is listed in this catalogue at the end of this section.

MODULAR CONDENSING
BOILERS

Example of 400 kW linear cascade

155
Modular wall-hung boilers for commercial applications
POWER PLUS - linear wall-hung or free-standing applications

Stand alone configuration 50 kW

CODE DESCRIPTION Q.TY


20019155 Power Plus 50 M 1
1102379* Remote control 1
20009472 Power Plus rig (front mounting) 1
20017270 I.N.A.I.L. connection pipes kit - 100 kW 1
20017271 Hydraulic header/separator - 100 kW 1
Hydraulic manifold kit 100 kW for
20017226 1
Power Plus rig with blank end-flange
LOW ENERGY pump kit (front)
20075526 1
for Power Plus rig
20009475** I.N.A.I.L. safety kit (400 kW max.) 1
20009486* Gas safety cut-off valve (115 kW max.) 1
4030311 Flues collector kit Ø 125 for 50 kW 1
20062337 Condensate drain kit Ø 125 with end cap 1
* OPTIONAL component
** I.N.A.I.L. optional component (I.N.A.I.L. = Italian safety certification
Institute)

Stand alone configuration 100 kW

CODE DESCRIPTION Q.TY


20019200 Power Plus 100 M 1
1102379* Remote control 1
20009472 Power Plus rig (front mounting) 1
20017270 I.N.A.I.L. connection pipes kit - 100 kW 1
20017271 Hydraulic header/separator - 100 kW 1
Hydraulic manifold kit 100 kW for
20017226 1
Power Plus rig with blank end-flange
LOW ENERGY pump kit (front)
20075526 2
for Power Plus rig
20009475** I.N.A.I.L. safety kit (400 kW max.) 1
20009486* Gas safety cut-off valve (115 kW max.) 1
4030312 Flues collector kit Ø 125 for 100 kW 1
20062337 Condensate drain kit Ø 125 with end cap 1
* OPTIONAL component
** I.N.A.I.L. optional component (I.N.A.I.L. = Italian safety certification
Institute)

156
Modular wall-hung boilers for commercial applications
POWER PLUS - linear wall-hung or free-standing applications

Linear cascade configuration 150 kW

CODE DESCRIPTION Q.TY


20019155 Power Plus 50 M 1
20019309 Power Plus 100 S 1
1102379* Remote control 1
20009472 Power Plus rig (front mounting) 2
Hydraulic manifold kit up to
20009439 2
400 kW for Power Plus rig
20009444 Blank end-flange kit for hydraulic manifold 1
LOW ENERGY pump kit (front)
20075526 3
for Power Plus rig
Hydraulic header/separator
20009466 1
(150 - 200 kW)
20009471 Hydraulic manifold (150 - 400 kW) 1
20009475** I.N.A.I.L. safety kit (400 kW max.) 1
20009482* Gas safety cut-off valve (230 kW max.) 1
4030311 Flues collector kit Ø 125 for 50 kW 1
4030312 Flues collector kit Ø 125 for 100 kW 1
20062337 Condensate drain kit Ø 125 with end cap 1
* OPTIONAL component
** I.N.A.I.L. optional component (I.N.A.I.L. = Italian safety certification
Institute)

Linear cascade configuration 200 kW

CODE DESCRIPTION Q.TY

MODULAR CONDENSING
20019200 Power Plus 100 M 1

BOILERS
20019309 Power Plus 100 S 1
1102379* Remote control 1
20009472 Power Plus rig (front mounting) 2
Hydraulic manifold kit up to
20009439 2
400 kW for Power Plus rig
20009444 Blank end-flange kit for hydraulic manifold 1
LOW ENERGY pump kit (front)
20075526 4
for Power Plus rig
Hydraulic header/separator
20009466 1
(150 - 200 kW)
20009471 Hydraulic manifold (150 - 400 kW) 1
20009475** I.N.A.I.L. safety kit (400 kW max.) 1
20009482* Gas safety cut-off valve (230 kW max.) 1
4030312 Flues collector kit Ø 125 for 100 kW 2
20062337 Condensate drain kit Ø 125 with end cap 1
* OPTIONAL component
** I.N.A.I.L. optional component (I.N.A.I.L. = Italian safety certification
Institute)

157
Modular wall-hung boilers for commercial applications
POWER PLUS - linear wall-hung or free-standing applications

Linear cascade configuration 250 kW

CODE DESCRIPTION Q.TY


20019155 Power Plus 50 M 1
20019309 Power Plus 100 S 2
1102379* Remote control 1
20009472 Power Plus rig (front mounting) 3
Hydraulic manifold kit up to
20009439 3
400 kW for Power Plus rig
20009444 Blank end-flange kit for hydraulic manifold 1
LOW ENERGY pump kit (front)
20075526 5
for Power Plus rig
Hydraulic header/separator
20009467 1
(250 - 460 kW)
20009471 Hydraulic manifold (150 - 400 kW) 1
20009475** I.N.A.I.L. safety kit (400 kW max.) 1
20009483* Gas safety cut-off valve (580 kW max.) 1
4030311 Flues collector kit Ø 125 for 50 kW 1
4030312 Flues collector kit Ø 125 for 100 kW 2
20062337 Condensate drain kit Ø 125 with end cap 1
* OPTIONAL component
** I.N.A.I.L. optional component (I.N.A.I.L. = Italian safety certification
Institute)

Linear cascade configuration 300 kW

CODE DESCRIPTION Q.TY


20019200 Power Plus 100 M 1
20019309 Power Plus 100 S 2
1102379* Remote control 1
20009472 Power Plus rig (front mounting) 3
Hydraulic manifold kit up to
20009439 3
400 kW for Power Plus rig
20009444 Blank end-flange kit for hydraulic manifold 1
LOW ENERGY pump kit (front)
20075526 6
for Power Plus rig
Hydraulic header/separator
20009467 1
(250 - 460 kW)
20009471 Hydraulic manifold (150 - 400 kW) 1
20009475** I.N.A.I.L. safety kit (400 kW max.) 1
20009483* Gas safety cut-off valve (580 kW max.) 1
4030312 Flues collector kit Ø 125 for 100 kW 3
20062337 Condensate drain kit Ø 125 with end cap 1
* OPTIONAL component
** I.N.A.I.L. optional component (I.N.A.I.L. = Italian safety certification
Institute)

158
Modular wall-hung boilers for commercial applications
POWER PLUS - linear wall-hung or free-standing applications

Linear cascade configuration 350 kW

CODE DESCRIPTION Q.TY


20019155 Power Plus 50 M 1
20019309 Power Plus 100 S 3
1102379* Remote control 1
20009472 Power Plus rig (front mounting) 4
Hydraulic manifold kit up to
20009439 4
400 kW for Power Plus rig
20009444 Blank end-flange kit for hydraulic manifold 1
LOW ENERGY pump kit (front)
20075526 7
for Power Plus rig
20009467 Hydraulic header/separator (250-460 kW) 1
20009471 Hydraulic manifold (150 - 400 kW) 1
20009475** I.N.A.I.L. safety kit (400 kW max.) 1
20009483* Gas safety cut-off valve (580 kW max.) 1
4030311 Flues collector kit Ø 125 for 50 kW 1
4030312 Flues collector kit Ø 125 for 100 kW 3
20062337 Condensate drain kit Ø 125 with end cap 1
* OPTIONAL component
** I.N.A.I.L. optional component (I.N.A.I.L. = Italian safety certification
Institute)

Linear cascade configuration 400 kW

CODE DESCRIPTION Q.TY

MODULAR CONDENSING
20019200 Power Plus 100 M 1

BOILERS
20019309 Power Plus 100 S 3
1102379* Remote control 1
20009472 Power Plus rig (front mounting) 4
Hydraulic manifold kit up to
20009439 4
400 kW for Power Plus rig
20009444 Blank end-flange kit for hydraulic manifold 1
LOW ENERGY pump kit (front)
20075526 8
for Power Plus rig
Hydraulic header/separator
20009467 1
(250 - 460 kW)
20009471 Hydraulic manifold (150 - 400 kW) 1
20009475** I.N.A.I.L. safety kit (400 kW max.) 1
20009483* Gas safety cut-off valve (580 kW max.) 1
4030312 Flues collector kit Ø 125 for 100 kW 4
20062337 Condensate drain kit Ø 125 with end cap 1
* OPTIONAL component
** I.N.A.I.L. optional component (I.N.A.I.L. = Italian safety certification
Institute)

159
Modular wall-hung boilers for commercial applications
POWER PLUS - back-to-back free-standing applications

Beretta offers in the following pages a wide choice of configurations of Power Plus series, among which you can choose the one that
best meets your requirements.
By matching the codes here below, according to the preferred installation solution and the power you need, Beretta suggests:

6 back-to-back free-standing configurations (from 150 to 400 kW)

CODE DESCRIPTION
1102379 Remote control
20009472 Power Plus rig (front mounting)
20009474 Rear mounting kit for Power Plus free-standing rig
20009439 Hydraulic manifold kit up to 400 kW for Power Plus rig
20009444 Blank end-flange kit for hydraulic manifold
20075526 LOW ENERGY pump kit (front) for Power Plus rig (ErP compliant)
20075527 LOW ENERGY pump kit (rear) for Power Plus rig (ErP compliant)
20009442 Pump kit (front) for Power Plus rig (non ErP compliant)
20009443 Pump kit (rear) for Power Plus rig (non ErP compliant)
20009466 Hydraulic header/separator (150-200 kW)
20009467 Hydraulic header/separator (250-460 kW)
20009471 Hydraulic manifold (150-400 kW)
20009475* I.N.A.I.L. safety kit (400 kW max.)
20009486 Gas safety cut-off valve (115 kW max.)
20009482 Gas safety cut-off valve (230 kW max.)
20009483 Gas safety cut-off valve (580 kW max.)
4030311 Flues collector kit Ø 125 for 50 kW
4030312 Flues collector kit Ø 125 for 100 kW
20062337 Condensate drain kit Ø 125 with end cap
20017306 Flues collector kit for frontal/rear installation

* Optional component (I.N.A.I.L. = Italian safety certification Institute).Beretta highly recommends safety devices also in countries where they are not compulsory.
The whole range of accessories and flues for POWER PLUS applications is listed in this catalogue at the end of this section.

Example of 400 kW back-to-back cascade

160
Modular wall-hung boilers for commercial applications
POWER PLUS - back-to-back free-standing applications

Back-to-back cascade configuration 150 kW

CODE DESCRIPTION Q.TY


20019155 Power Plus 50 M 1
20019309 Power Plus 100 S 1
1102379* Remote control 1
20009472 Power Plus rig (front mounting) 1
Rear mounting kit for Power
20009474 1
Plus free-standing rig
Hydraulic manifold kit up to 400
20009439 1
kW for Power Plus rig
20009444 Blank end-flange kit for hydraulic manifold 1
LOW ENERGY pump kit (front)
20075526 1
for Power Plus rig
LOW ENERGY pump kit (rear)
20075527 2
for Power Plus rig
20009466 Hydraulic header/separator (150 - 200 kW) 1
20009471 Hydraulic manifold (150 - 400 kW) 1
20009475** I.N.A.I.L. safety kit (400 kW max.) 1
20009482* Gas safety cut-off valve (230 kW max.) 1
4030311 Flues collector kit Ø 125 for 50 kW 1
4030312 Flues collector kit Ø 125 for 100 kW 1
20062337 Condensate drain kit Ø 125 with end cap 2
20017306 Flues collector kit for frontal/rear installation 1
* OPTIONAL component
** I.N.A.I.L. optional component (I.N.A.I.L. = Italian safety certification
Institute)

Back-to-back cascade configuration 200 kW

MODULAR CONDENSING
CODE DESCRIPTION Q.TY

BOILERS
20019200 Power Plus 100 M 1
20019309 Power Plus 100 S 1
1102379* Remote control 1
20009472 Power Plus rig (front mounting) 1
Rear mounting kit for Power
20009474 1
Plus free-standing rig
Hydraulic manifold kit up to 400
20009439 1
kW for Power Plus rig
20009444 Blank end-flange kit for hydraulic manifold 1
LOW ENERGY pump kit (front)
20075526 2
for Power Plus rig
LOW ENERGY pump kit (rear)
20075527 2
for Power Plus rig
20009466 Hydraulic header/separator (150 - 200 kW) 1
20009471 Hydraulic manifold (150 - 400 kW) 1
20009475** I.N.A.I.L. safety kit (400 kW max.) 1
20009482* Gas safety cut-off valve (230 kW max.) 1
4030312 Flues collector kit Ø 125 for 100 kW 2
20062337 Condensate drain kit Ø 125 with end cap 2
20017306 Flues collector kit for frontal/rear installation 1
* OPTIONAL component
** I.N.A.I.L. optional component (I.N.A.I.L. = Italian safety certification
Institute)
161
Modular wall-hung boilers for commercial applications
POWER PLUS - back-to-back free-standing applications

Back-to-back cascade configuration 250 kW

CODE DESCRIPTION Q.TY


20019155 Power Plus 50 M 1
20019309 Power Plus 100 S 2
1102379* Remote control 1
20009472 Power Plus rig (front mounting) 2
Rear mounting kit for Power
20009474 2
Plus free-standing rig
Hydraulic manifold kit up to 400
20009439 2
kW for Power Plus rig
20009444 Blank end-flange kit for hydraulic manifold 1
LOW ENERGY pump kit (front)
20075526 3
for Power Plus rig
LOW ENERGY Pump kit (rear)
20075527 2
for Power Plus rig
20009467 Hydraulic header/separator (250-460 kW) 1
20009471 Hydraulic manifold (150 - 400 kW) 1
20009475** I.N.A.I.L. safety kit (400 kW max.) 1
20009483* Gas safety cut-off valve (580 kW max.) 1
4030311 Flues collector kit Ø 125 for 50 kW 1
4030312 Flues collector kit Ø 125 for 100 kW 2
20062337 Condensate drain kit Ø 125 with end cap 2
20017306 Flues collector kit for frontal/rear installation 1
* OPTIONAL component
** I.N.A.I.L. optional component (I.N.A.I.L. = Italian safety certification
Institute)

Back-to-back cascade configuration 300 kW

CODE DESCRIPTION Q.TY


20019200 Power Plus 100 M 1
20019309 Power Plus 100 S 2
1102379* Remote control 1
20009472 Power Plus rig (front mounting) 2
Rear mounting kit for Power
20009474 2
Plus free-standing rig
Hydraulic manifold kit up to 400
20009439 2
kW for Power Plus rig
20009444 Blank end-flange kit for hydraulic manifold 1
LOW ENERGY pump kit (front)
20075526 4
for Power Plus rig
LOW ENERGY pump kit (rear)
20075527 2
for Power Plus rig
20009467 Hydraulic header/separator (250-460 kW) 1
20009471 Hydraulic manifold (150 - 400 kW) 1
20009475** I.N.A.I.L. safety kit (400 kW max.) 1
20009483* Gas safety cut-off valve (580 kW max.) 1
4030312 Flues collector kit Ø 125 for 100 kW 3
20062337 Condensate drain kit Ø 125 with end cap 2
20017306 Flues collector kit for frontal/rear installation 1
* OPTIONAL component
** I.N.A.I.L. optional component (I.N.A.I.L. = Italian safety certification
Institute)
162
Modular wall-hung boilers for commercial applications
POWER PLUS - back-to-back free-standing applications

Back-to-back cascade configuration 350 kW

CODE DESCRIPTION Q.TY


20019155 Power Plus 50 M 1
20019309 Power Plus 100 S 3
1102379* Remote control 1
20009472 Power Plus rig (front mounting) 2
Rear mounting kit for Power
20009474 2
Plus free-standing rig
Hydraulic manifold kit up to 400
20009439 2
kW for Power Plus rig
20009444 Blank end-flange kit for hydraulic manifold 1
LOW ENERGY pump kit (front)
20075526 3
for Power Plus rig
LOW ENERGY pump kit (rear)
20075527 4
for Power Plus rig
20009467 Hydraulic header/separator (250-460 kW) 1
20009471 Hydraulic manifold (150 - 400 kW) 1
20009475** I.N.A.I.L. safety kit (400 kW max.) 1
20009483* Gas safety cut-off valve (580 kW max.) 1
4030311 Flues collector kit Ø 125 for 50 kW 1
4030312 Flues collector kit Ø 125 for 100 kW 3
20062337 Condensate drain kit Ø 125 with end cap 2
20017306 Flues collector kit for frontal/rear installation 1
* OPTIONAL component
** I.N.A.I.L. optional component (I.N.A.I.L. = Italian safety certification
Institute)

Back-to-back cascade configuration 400 kW

MODULAR CONDENSING
CODE DESCRIPTION Q.TY

BOILERS
20019200 Power Plus 100 M 1
20019309 Power Plus 100 S 3
1102379* Remote control 1
20009472 Power Plus rig (front mounting) 2
Rear mounting kit for Power
20009474 2
Plus free-standing rig
Hydraulic manifold kit up to 400
20009439 2
kW for Power Plus rig
20009444 Blank end-flange kit for hydraulic manifold 1
LOW ENERGY pump kit (front)
20075526 4
for Power Plus rig
LOW ENERGY pump kit (rear)
20075527 4
for Power Plus rig
20009467 Hydraulic header/separator (250-460 kW) 1
20009471 Hydraulic manifold (150 - 400 kW) 1
20009475** I.N.A.I.L. safety kit (400 kW max.) 1
20009483* Gas safety cut-off valve (580 kW max.) 1
4030312 Flues collector kit Ø 125 for 100 kW 4
20062337 Condensate drain kit Ø 125 with end cap 2
20017306 Flues collector kit for frontal/rear installation 1
* OPTIONAL component
** I.N.A.I.L. optional component (I.N.A.I.L. = Italian safety certification
Institute)
163
Modular wall-hung boilers for commercial applications
SPECIFIC ACCESSORIES FOR POWER PLUS

Components and accessories for Power Plus tailor-made installation solutions

The complete line of components and accessories developed by Beretta, hereafter listed and shown, in addition to the configurations
proposed in this catalogue, allow you to compose also tailor-made Power Plus cascade applications.
By choosing all Beretta components, that harmonize perfectly with each other, your Power Plus system will assure you the maximum
comfort and savings that are provided only by a unique specialized supplier.

CODE DESCRIPTION

1102379 Remote control

1102869 Low temperature kit

1103059 Probe kit for DHW tank

20016110 Zone Master kit

20073129 Mod-Bus interface (cables included)

20046946 Interface kit for PC

20011126 Condensate Neutralizer N2 up to 320 kW

20011132 Condensate Neutralizer N3 up to 1250 kW

20011135 Condensate Neutralizer HN2 (with pump) - up to 320 kW

20011162 Condensate Neutralizer HN3 (with pump) - up to 1250 kW

Primary loop pump < 270kW for P.P. Hs 300kW (with


20021898 connections and electronic injection pump type VegA
RMDA 50-80)

Primary loop pump < 450kW for P.P. Hs 500kW (with


20021900 connections and electronic injection pump type VegA
RMDA 80-90)

164
Modular wall-hung boilers for commercial applications
SPECIFIC COMPONENTS FOR POWER PLUS

20009439 20009442 20075526 20009443 20075527

Hydraulic manifold kit up to Pump kit (front) for Power LOW ENERGY pump kit (front) for Pump kit (rear) for Power Plus LOW ENERGY pump kit (rear) for
400 kW for Power Plus rig Plus rig (no ErP compliant) Power Plus rig (ErP compliant) rig (no ErP compliant) Power Plus rig (ErP compliant)

20009444 20009466 20009467 20009471 20009472

Blank end-flange kit for Hydraulic header/ Hydraulic header/ Hydraulic manifold Power Plus rig
hydraulic manifold (400 kW) separator (150-200 kW) separator (250-460 kW) (150-400kW) (front mounting)

20041367 20009475** 20009486 20009482 20009483

MODULAR CONDENSING
Two-ways-valve kit I.N.A.I.L. safety kit Gas safety cut-off valve Gas safety cut-off valve Gas safety cut-off valve

BOILERS
(only front mounting) (400 kW max.) (115 kW max.) (230 kW max.) (580 kW max.)

20017270 20017271 20017226 10029891 20072821

Hydraulic manifold kit


I.N.A.I.L. connection pipes kit Hydraulic header/separator 100 kW for P. P. rig with Connections kit for LOW ENERGY pump kit
- 100 kW - 100 kW blank end-flange injection pump for secondary circuit

* This component is
20009474* 20018456 1102579 1102589
recommended also for
linear free-standing cascade
installations to provide extra
stability where needed.
** It contains:
- temperature gauge
- pressure gauge
- pressure switch
Rear mounting kit for Supports hydraulic manifold Blind flange 3” UNI 60/91 Flange 3” UNI 2276-67 - connection plug with valve
Power Plus free-standing rig kit (without rig) from 150 kW PN6 DN80 PN6 DN80

165
Modular wall-hung boilers for commercial applications
FLUES FOR POWER PLUS

Flue Headers

CODE DESCRIPTION

4030311 Flues collector kit Ø 125 for 50 kW

4030019 Flues collector kit Ø 160 for 50 kW

20062323 Flues collector kit Ø 200 for 50 kW

4030312 Flues collector kit Ø 125 for 100 kW

4030037 Flues collector kit Ø 160 for 100 kW

20062312 Flues collector kit Ø 200 for 100 kW

20062337 Condensate drain kit Ø 125 with end cap

20062338 Condensate drain kit Ø 160 with end cap

20062340 Condensate drain kit Ø 200 with end cap

20062332 End cap Ø 125

20062333 End cap Ø 160

20062335 End cap Ø 200

Room-sealed Kits

CODE DESCRIPTION

1102439 Air connection kit to Power Plus 50 kW 2

1102449 Air connection kit to Power Plus 100 kW


2

166
Modular wall-hung boilers for commercial applications
FLUES FOR POWER PLUS

Indoor flue systems Ø 50

CODE DESCRIPTION

20031841 45° bend Ø 50 (white PPS)

20031840 90° bend Ø 50 (white PPS)

20021607 Extension Ø 50, 250 mm (white PPS)

20021608 Extension Ø 50, 500 mm (white PPS)

20021609 Extension Ø 50, 1000 mm (white PPS)

20031842 Condensate drain kit Ø 50 (white PPS)

20027815 Non-return flue valve kit Ø 50/80 (PPtl) - clapet

20071446 Flue adapter Ø 50/80 (PPtl)

MODULAR CONDENSING
BOILERS
Indoor flue systems Ø 60

CODE DESCRIPTION

20046016 Extension Ø 60, 640 mm (black PPS)

20046015 87° Bend Ø 60 (black PPS)

20046028 Air intake/flue drain kit Ø 60 (black PPS) (terminal UV protected)

167
Modular wall-hung boilers for commercial applications
FLUES FOR POWER PLUS

Indoor flue systems Ø 80/125

CODE DESCRIPTION

20064739 Concentric flue adapter kit Ø 50/50 - 80/125 (PPtl)

Indoor flue systems Ø 125

CODE DESCRIPTION

20027816 Chimney kit Ø 125

20037431 Chimney cover Ø 125 (PP & stainless steel)

20037429 Chimney support Ø 125 (PPtl, EPDM, MET)

20037424 Inspection extension Ø 125 (PPtl)

20017306 Flues collector kit for frontal/rear installation (PPtl, for cascade back-to-back)

20037426 Pipe spacers kit Ø 125 (PP), 5 pcs.

20037396 45° bend kit Ø 125 (PPtl)

20037405 90° bend kit Ø 125 (PPtl)

20037413 Extension Ø 125, 500 mm (PPtl)

168
Modular wall-hung boilers for commercial applications
FLUES FOR POWER PLUS

Indoor flue systems Ø 125

CODE DESCRIPTION

20037415 Extension Ø 125, 1000 mm (PPtl)

20037416 Extension Ø 125, 2000 mm (PPtl)

Indoor flue systems Ø 160

CODE DESCRIPTION

20032653 Chimney kit Ø 160

20060945 Inspection extension Ø 160 (PPtl)

20060948 Pipe spacers kit Ø 160 (plastic), 5 pcs.

20032646 45° bend kit Ø 160 (PPtl)

MODULAR CONDENSING
BOILERS
20032644 90° bend kit Ø 160 (PPtl)

20060940 Extension Ø 160, 500 mm (PPtl)

20060941 Extension Ø 160, 1000 mm (PPtl)

20060942 Extension Ø 160, 2000 mm (PPtl)

169
Modular floor-standing boilers for commercial applications
POWER PLUS BOX - 500 SERIES
Ŷ Floor-standing, modular condensing boilers complete
with hydraulic collectors and hydraulic header/separator,
gas collectors, flues collectors in plastic with clapet and
condensate drain kit.
Ŷ Suitable only for stand-alone application.
Ŷ Stainless steel BOX with IPx4D protection and insulation, specifically
designed for OUTDOOR installation.
Ŷ It can be installed INDOOR as well.
Ŷ Efficiency ++++ according to European Directive EEC 92/42.
Ŷ Minimum polluting emissions: class 5 (UNI EN 483).
Ŷ Climatic curves on board.
Ŷ Flue temperature of only max 3°C above the return water
temperature.
Ŷ Maximum ease of installation.
Ŷ All models are provided with a Low Energy main pump and a
two-ways valve for each heat exchanger.
Ŷ Possibility to integrate the secondary pumps inside the BOX (as
optional accessory, as shown below)

BOX for OUTDOOR / INDOOR installation

DIMENSIONS
INPUT INPUT
CODE GAS MODEL H ×W × D
(kW) Hs (kW) Hi
(mm)

20107448 NG POWER PLUS LE 85 SYS 1530 × 1250 × 650 85 77

20107449 NG POWER PLUS LE HI 115 SYS 1530 × 1250 × 650 128 115

Specific accessories

CODE DESCRIPTION CODE DESCRIPTION

Low temperature circuit kit (rif.1) 20069667 DHW tank kit (rif.3) with LOW ENERGY pump
20069666
with LOW ENERGY pump
20011175 System connections kit
High temperature circuit kit (rif.2)
20069664
with LOW ENERGY pump 20074999 Plugs kit (2 pcs)

POWER PLUS LE 85 SYS POWER PLUS LE HI 115 SYS

1 1

2 2
3 3

170
Modular floor-standing boilers for commercial applications
POWER PLUS BOX - 500 SERIES

D L

R 150
G
H

1041
SC
433

104

Technical specifications

DESCRIPTION POWER PLUS LE 85 SYS POWER PLUS LE HI 115 SYS

Heat input (Hs) kW 85,2 127,8


Heat input (Hi) kW 76,7 115
Nominal heat output (80°-60°C) kW 75,3 112,9
Nominal heat output (50°-30°C) kW 82,5 123,8
Minimum heat input (Hs) kW 16 16
Minimum heat input (Hi) kW 14,4 14,4
Efficiency according European
++++
Directive EEC 92/42
Efficiency at nominal output (80°-60°C) (HI) % 98,2
Efficiency at nominal output (50°-30°C) (HI) % 107,7
Efficiency at partial load 30% (80°-60°C) (HI) % 98,7

MODULAR CONDENSING
Efficiency at partial load 30% (50°-30°C) (HI) % 108,7
Emissions

BOILERS
NOx class 5
CO d.a.f. min-max less than mg/kWh 10/80
Flue gas temperature °C T return + MAX 2,5 °C
Central heating
Maximum pressure bar 6
Adjustable CH water temperature range °C 20/80
Max condensate production l/h 11,1 16,6
Electrical
Power supply V-Hz 230-50
Maximum power consumption W 310 359
Dimensions, weight, gas
Boiler dimensions (H x L x D) mm 1530 x 1250 x 650
Net weight (empty) kg 180 220
Water content l 10 15
Available gas versions NG/LPG
G (Gas manifolds) Ø 2”
M/R (flow and Return manifolds) Ø 2” / 2”
SC (Condensate manifolds) mm 50
Ø (Flue header outlet) mm 125

171
Modular floor-standing boilers for commercial applications
POWER PLUS BOX - 500 SERIES

Ŷ Floor-standing, modular condensing boilers complete with


hydraulic collectors, gas collectors, flues collectors in PPtl
with “clapet” (non-return valve), condensate drain kit and
embedded Low Energy shunt pumps.
Ŷ Zync coated, steel BOX specifically painted for OUTDOOR and INDOOR
installation, with ventilation air intake.
Ŷ Efficiency ++++ according to European Directive EEC 92/42.
Ŷ Minimum polluting emissions: class 5 (UNI EN 483)
Ŷ Climatic curves on board.
Ŷ Possibility to cascade more than one appliance to reach up to
3.000 kW.
Ŷ Index of electrical protection IPX4D
Ŷ Electronic cascade control on board.
Ŷ LPG gas conversion kit on board.

BOX for OUTDOOR / INDOOR installation


DIMENSIONS
INPUT INPUT
CODE GAS MODEL H ×W × D
(kW) Hs (kW) Hi
(mm)
ONLY HEATING

20071998 NG POWER PLUS BOX 150 (1) 1530 × 1250 × 650 150 135

20071999 NG POWER PLUS BOX 200 (1) 1530 × 1250 × 650 200 180

20072002 NG POWER PLUS BOX 100 SE (2) 1530 × 1250 × 650 100 90

(1) Power Plus BOX boilers are equipped with the “blind flanges kit for 500-series” (code 20075887) and with the “Power Plus junction kit for
cascade” (code 20074998) for cascade installation.
(2) The thermal module Power Plus BOX SE is complete with hydraulic separator, safety-devices up to 300kW, and safety gas cut-off valve and can be
installed in stand-alone or in cascade applications with one Power Plus BOX 150 or one Power Plus BOX 200. In case of stand-alone application it
is possible to buy the “blind flanges kit for 500-series” (code 20075887).

POWER PLUS BOX 150 POWER PLUS BOX 200 POWER PLUS BOX 100 SE
Error

Error
RESET

RESET
On

On

5.5
bar

172
Modular floor-standing boilers for commercial applications
POWER PLUS BOX - 500 SERIES

BOX 100 SE BOX 150/200 BOX 150/200/100 SE

650 660 1250 1250


795
G1 G1
F
M1 171
F M1
M1
170
450

M2 G
M2 M2
1483

1530
1490
G

1357
1370

1300
195
300

1224
M
R2 R2
M
M R2 M
810

775
SC
220

R1 SC
R1 R1

477
460

260
R R R
261

142

354 296 95
295
650

Technical specifications

Power Plus BOX Power Plus BOX Power Plus BOX


DESCRIPTION
150 200 100 SE
Fuel - G20 - G30 - G31
Appliance Category - II2H3+
Type of Appliance - B23
Heat input ref. Hs (min-max) kW 16.0 - 150.0 16.0 - 200 16.0 - 100.0
Heat input ref. Hi (min-max) kW 14.4 - 134.9 14.4 -179,8 14.4 - 89.9
Nominal heat output (80°-60°C) (min-max) kW 14.4 - 132.5 14.4 - 176.6 14.4 - 88.3
Nominal heat output (50°-30°C) (min-max) kW 16.0 - 145.3 16.0 - 193.6 16.0 - 96.8
Minimum heat input (Hs) kW 16 16 16
Minimum heat input (Hi) kW 14.4 14.4 14.4
Efficiency according European Directive EEC 92/42 - ++++
Efficiency at nominal output (80°-60°C) (Hi) % 98.2 98.2 98.2
Efficiency at nominal output (50°-30°C) (Hi) % 107.7 107.7 108.3
Efficiency at nominal output (60°-40°C) (Hi) % 106.1 106.1 106.1
Efficiency at partial load 30% (80°-60°C) (Hi) % 98.7 98.7 98.7
Efficiency at partial load 30% (50°-30°C) (Hi) % 108.7 108.7 108.7
Efficiency at partial load 30% (60°-40°C) (Hi) % 106.6 106.6 106.6

MODULAR CONDENSING
Gas Rates
Gas capacity (min - max) G20 Sm3/h 1.5 - 13.8 1.5 - 18.4 1.5 - 9.2

BOILERS
Gas capacity (min - max) G30 kg/h 1 - 9.8 1 - 13.1 1 - 6.5
Gas capacity (min - max) G31 kg/h 1 - 9.7 1 - 12.9 1 - 6.4
Emissions
CO2 at minimum - maximum % 9.0 (G20) - 10.4 (G30-G31)
CO d.a.f. min-max less than mg/kWh 11-91
Flue gas temperature °C T return + MAX 2,5 °C
NOx Class 5
Central Heating
Working Pressure (min-max) bar 0.5 - 6
Adjustable CH water temperature range °C 20 - 80
Water content l 15 20 70
Max condensate production l/h 20.7 27.6 13.8
Electrical
Power supply V-Hz 230-50 230-50 230-50
Maximum power consumption W 495 660 330
Index of electrical protection IP IPX4D
Dimensions, Weight and Gas
Boiler dimensions (H x W x D) mm 1530 x 1250 x 650
Dry weight kg 310 340 200
Available gas versions - NG / LPG NG / LPG NG / LPG
G (Gas manifolds) Ø 3” DN 80 - PN 6 3” DN 80 - PN 6 3” DN 80 - PN 6
G1 (Gas manifolds) - - 2” (threaded)
M/R (Flow and Return flanged manifolds) Ø 5” DN 125 - PN 6 5” DN 125 - PN 6 5” DN 125 - PN 6
M1/M2/R1/R2 (Flow and Return flanged manifolds) Ø 3” DN 80 - PN 6 3” DN 80 - PN 6 3” DN 80 - PN 6
SC (Condensate manifold) Ø mm 50 50 50
F (Flue header Outlet) Ø mm 160 160 160

173
Modular floor-standing boilers for commercial applications
POWER PLUS BOX - 1000 SERIES
Ŷ Floor-standing, modular condensing boilers complete with 5”
hydraulic collectors, 3” gas collector, flue outlets Ø 110mm
and condensate drain kit.
Ŷ Painted steel BOX for indoor installations with ventilation air intake.
Ŷ Efficiency ++++ according to European Directive EEC 92/42.
Ŷ Minimum polluting emissions: class 5 (UNI EN 483).
Ŷ Climatic curves available with Master Control (accessory).
Ŷ Possibility to cascade up to 60 combustion units.
Ŷ Electronic cascade control managed by Master Control.
Ŷ Flue temperature of only around 8°C above the return water
temperature.
Ŷ Power Plus Box is provided with Low Energy shunt pumps.
Ŷ Clapet built-in.

BOX for INDOOR installation

DIMENSIONS
INPUT INPUT
CODE GAS MODEL H ×W × D
(kW) Hs (kW) Hi
(mm)

WITH LOW ENERGY SHUNT PUMPS

20107464 NG POWER PLUS BOX 1002 P INT 1590 × 900 × 750 256 230
20107472 NG POWER PLUS BOX 1003 P INT 1590 × 1700 × 750 384 345
20107478 NG POWER PLUS BOX 1004 P INT 1590 × 1700 × 750 511 460

Electronic control for cascade management

CODE DESCRIPTION

Master board (manages the thermal modules cascade;


20067837*
contains blind flanges kit and external probe)

* It is necessary to order a master board for the whole cascade system.

Specific accessories

CODE DESCRIPTION CODE DESCRIPTION


20069767 Flues collector 4x110 - 1x200 1102379 Remote control kit
20069769 Flues collector 3x110 - 1x200 XKIT1460E Isolating valve for single heat-exchanger
Flues collector 1x110 - 1x200 20069073 Hydraulic separator INT 100 ÷ 640 kW (rif. 2 )
20069771
(for 2-engines box purchase 2)
Hydraulic separator INT MAX 1024 kW
20062340 Condensate drain kit Ø 200 with end cap 20069074
(suitable up to 10 engines) (rif. 2 )
20061638 Gas safety cut-off valve (580 kW max.) Hydraulic manifold connection to low header
20069075
20061640 Gas safety cut-off valve (1150 kW max.) and safety devices - right (rif. 1 )
20076316 Extension kit Ø 110 with inspection Hydraulic manifold connection to low
20069072
header and safety devices - left (rif. 1 )
20061644 Safety kit
174
Modular floor-standing boilers for commercial applications
POWER PLUS BOX - 1000 SERIES

Power Plus Box 1002 Power Plus Box 1003 - Power Plus Box 1004

1 2
287
287

365
365
165

165
1550

1590

1590

1550

850
1590

1590
473
473
313

313
285

285
900 1700 390 516
190 370 190 190 370 190
908
750 750 2260
1250

Technical specifications

POWER PLUS BOX POWER PLUS POWER PLUS


DESCRIPTION
1002 P INT BOX 1003 P INT BOX 1004 P INT
Boiler type B23, B53, B53P, C13, C33, C53, C63
CE Homologation Number 0085CL0333
Number of burners 2 (x128 kW) 3 (x128 kW) 4 (x128 kW)
Dimension and Connections
HxLxD mm 1590x900x750 1590x1700x750
Empty weight kg 270 380 450
Content of water l 77 123 149
Water manifold Ø 5”
Gas manifold Ø 3”
Flue manifold Ø mm 110
Condensate drain Ø mm 50
Power and Efficiency
Heat input ref. HHV (min - max) kW 25,5 - 255,6 25,5 - 383,4 25,5 - 511,2

MODULAR CONDENSING
Heat input ref. NHV (min - max) kW 23 - 230 23 - 345 23 - 460
Useful heat output (80°/60°C) kW 226,8 340,2 453,6

BOILERS
Useful heat output (50°/30°C) kW 249,8 374,7 499,6
Useful heat output (60°/40°C) kW 239,6 359,4 479,2
Condensate production per hour at 100% (50 - 30°C) - gas G20 kg/h 34,4 51,6 68,8
Useful efficiency ref. NHV (80°C/60°C) % 98,6 98,6 98,6
Useful efficiency ref. NHV (50°C/30°C) % 108,6 108,6 108,6
Useful efficiency ref. NHV Tm=50°C (60/40°C) % 104,2 104,2 104,2
Useful efficiency at 30% ref. NHV (80°C/60°C) % 99,2 99,2 99,2
Useful efficiency at 30% ref. NHV (50°C/30°C) % 109 109 109
Useful efficiency at 30% ref. NHV Tm=50°C (60 – 40°C) % 105 105 105
Losses through the casing (Tm=70°) % 0,1 0,1 0,1
Efficiency Class 92/42 CEE ++++
Consumption and electrical power
Gas Category II2H3+
Gas consumption (G20) (min / rated) m3/h 2,43 / 24,3 2,43 / 36,5 2,43 / 48,7
Power supply V/Hz 230 - 50
Maximum electrical consumption (boiler + LOW ENERGY pump) W 580 870 1160
Maximum electrical consumption (only boiler) W 300 450 600
Combustion data
Max exhaust residual manometric head for each unit Pa 500
CO (0% di O2) (min÷max) mg/kWh 23 ÷130
NOx class 5
Heating circuit
Heating temperature regulation (min / max) °C 20 / 80
Water operating pressure (max / min) bar (kPa) 6 / 0,5 (600/50)
Max manometric head at nominal flow of 5’500 l/h Pa [m c.a.] 1500 [1,5]
175
Modular floor-standing boilers for commercial applications
POWER PLUS BOX - 1000 SERIES
Ŷ Floor-standing, modular condensing boilers complete with
5” hydraulic collectors flow and return, 3” gas collector, flue
outlets Ø 110mm and condensate drain kit.
Ŷ Stainless-steel BOX for outdoor installations with ventilation air intake.
Ŷ Efficiency ++++ according to European Directive EEC 92/42.
Ŷ Minimum polluting emissions: class 5 (UNI EN 483).
Ŷ Climatic curves available with Master Control (accessory).
Ŷ Possibility to cascade up to 60 combustion units.
Ŷ Electronic cascade control managed by Master Control.
Ŷ Flue temperature of only around 8°C above the return water
temperature.
Ŷ Power Plus Box is provided with Low Energy shunt pumps.
Ŷ Clapet built-in.

BOX for OUTDOOR installation

DIMENSIONS
INPUT INPUT
CODE GAS MODEL H ×W × D
(kW) Hs (kW) Hi
(mm)

WITH LOW ENERGY SHUNT PUMPS

20107469 NG POWER PLUS BOX 1002 P EXT 1637 × 900 × 750 256 230

20107477 NG POWER PLUS BOX 1003 P EXT 1637 × 1710 × 750 384 345

20107479 NG POWER PLUS BOX 1004 P EXT 1637 × 1710 × 750 511 460

Electronic control for cascade management

CODE DESCRIPTION

Master board (manages the thermal modules cascade;


20067837*
contains blind flanges kit and external probe)

* It is necessary to order a master board for the whole cascade system.

Specific accessories

CODE DESCRIPTION CODE DESCRIPTION

20060817 Terminal chimney inox 20061644 Safety kit


20060819 Kit extention stainless steel 500 mm, Ø 110 20060827 Hydraulic separator in BOX up to 640 kW - right (rif. 1 )
20060820 Kit extention stainless steel 1000 mm, Ø 110 20060828 Hydraulic separator in BOX up to 640 kW - left (rif. 1 )
20060821 90° bend stainless steel, Ø 110 20060829 Hydraulic separator in BOX up to 1150 kW - right (rif. 1 )
20061638 Gas safety cut-off valve (580 kW max.) 20060830 Hydraulic separator in BOX up to 1150 kW - left (rif. 1 )
20061640 Gas safety cut-off valve (1150 kW max.) XKIT1460E Isolating valve for single heat-exchanger

176
Modular floor-standing boilers for commercial applications
POWER PLUS BOX - 1000 SERIES
Power Plus Box 1002 Power Plus Box 1003 - Power Plus Box 1004

1
1637

850
310
100

898 750
190 908

Technical specifications

POWER PLUS POWER PLUS POWER PLUS


DESCRIPTION
BOX 1002 P EXT BOX 1003 P EXT BOX 1004 P EXT
Boiler type B23, B53, B53P, C13, C33, C53, C63
CE Homologation number 0085CL0333
Number of burners 2 (x128 kW) 3 (x128 kW) 4 (x128 kW)
Dimension and Connections
HxLxD mm 1637x900x750 1637x1710x750
Empty weight kg 270 380 450
Content of water l 77 123 149
Water manifold Ø 5”
Gas manifold Ø 3”
Flue manifold Ø mm 110
Condensate drain Ø mm 50
Power and Efficiency
Heat input ref. HHV (min - max) kW 25,5 - 255,6 25,5 - 383,4 25,5 - 511,2

MODULAR CONDENSING
Heat input ref. NHV (min - max) kW 23 - 230 23 - 345 23 - 460
Useful heat output (80°/60°C) kW 226,8 340,2 453,6

BOILERS
Useful heat output (50°/30°C) kW 249,8 374,7 499,6
Useful heat output (60°/40°C) kW 239,6 359,4 479,2
Condensate production per hour at 100% (50 - 30°C) - G20 kg/h 34,4 51,6 68,8
Useful efficiency ref. NHV (80°C/60°C) % 98,6 98,6 98,6
Useful efficiency ref. NHV (50°C/30°C) % 108,6 108,6 108,6
Useful efficiency ref. NHV Tm=50°C (60/40°C) % 104,2 104,2 104,2
Useful efficiency at 30% ref. NHV (80°C/60°C) % 99,2 99,2 99,2
Useful efficiency at 30% ref. NHV (50°C/30°C) % 109 109 109
Useful efficiency at 30% ref. NHV Tm=50°C (60 – 40°C) % 105 105 105
Losses through the casing (Tm=70°) % 0,1 0,1 0,1
Efficiency class 92/42 CEE ++++
Consumption and electrical power
Gas category II2H3+
Gas consumption (G20) (min / rated) m3/h 2,43 / 24,3 2,43 / 36,5 2,43 / 48,7
Power supply V - Hz 230- 50
Maximum electrical consumption (boiler + pump) W 580 870 1160
Maximum electrical consumption (only boiler) W 300 450 600
Combustion data
Max exhaust residual manometric head for each unit Pa 500
CO (0% di O2) (min / max) mg/kWh 23 / 130
NOx Class 5
Heating circuit
Heating temperature regulation (min / max) °C 20 / 80
Water operating pressure (max / min) bar (kPa) 6 / 0,5 (600 / 50)
Max manometric head at nominal flow of 5’500 l/h Pa [m c.a.] 1500 [1,5]
177
Modular floor-standing boilers for commercial applications
POWER PLUS BOX - 1000 SERIES
Ŷ Stand-alone floor standing condensing boiler 115 kW with pre-
assembled hydronic header and multi-zones kit.
Ŷ Painted steel BOX for indoor installations with ventilation air intake.
Ŷ Stainless-steel BOX for outdoor installations with sloping top cover
and ventilation air intake.
Ŷ Efficiency ++++ according to European Directive EEC 92/42,
ensuring low running costs.
Ŷ Minimum polluting emissions: class 5 (UNI EN 483).
Ŷ Compact dimensions.
Ŷ Ready for installation.
Ŷ Power Plus Box 1001 is a floor-standing condensing boiler available
in the following models:
- Power Plus Box 1001 INT (for indoor installation, painted box).
- Power Plus Box 1001 EXT (specific for outdoor installation,
stainless-steel box).
Ŷ This compact boiler is ready for installation and consists of:
boiler unit, Low Energy A-Class modulating pump, hydraulic
separator, I.N.A.I.L.* hydraulic manifold with safety devices and
flues collector.
Ŷ Heat-generator also includes: system drain tap, exchangers drain tap,
gas tap, condensate drain collector, safety valve, air vent, external
probe, high and low temperature probes, domestic water probe and
LPG conversion kit.
Ŷ High flexibility of installation: possibility of managing one direct zone,
one mixed zone and a DHW tank through the electronic board of
the master boiler. Specific accessories are available to control more
mixed zones.

OUTDOOR INDOOR * I.N.A.I.L. = Italian safety certification Institute. Beretta highly recommends
(EXT) (INT) safety devices also in countries where they are not compulsory.

Dedicated BOX for OUTDOOR and INDOOR installation

DIMENSIONS
INPUT INPUT
CODE GAS MODEL H ×W × D
(kW) Hs (kW) Hi
(mm)
WITH LOW ENERGY SHUNT PUMPS

20067835 NG POWER PLUS BOX 1001 INT (115 all inside) 1590 × 900 × 750 128 115

20067836 NG POWER PLUS BOX 1001 EXT (115 all inside) 1640 × 900 × 750 128 115

Note: the Power Plus Box 1001 INT/EXT comes with an embedded hydraulic separator up to 150 kW

Specific accessories

CODE DESCRIPTION CODE DESCRIPTION

20069664 High temperature circuit kit 1102379 Remote control kit


20069666 Low temperature circuit kit 20016110 Zone Master kit
20069667 DHW tank kit 20074999 Plugs kit (2 pcs)
20011175 Systems connections kit

178
Modular floor-standing boilers for commercial applications
POWER PLUS BOX - 1000 SERIES

POWER PLUS BOX 1001 INT (115 all inside) POWER PLUS BOX 1001 EXT (115 all inside)

580

355 139 355 139

35

140 180 110110


35
140 180 110110

69 69

256
256

506

1637
506

1590

290
290

140
140

290
290

387
387

154

93
154

100
93

100
898 750 898 750
344 125
344 125
410
410
482
482

Technical specifications

POWER PLUS BOX 1001 INT


DESCRIPTION
POWER PLUS BOX 1001 EXT
Boiler type B23, B53, B53p
EC Homologation number 0085CL0333
Dimension and Connections
HxLxD (Power Plus Box 1001 INT) mm 1590x898x750
HxLxD (Power Plus Box 1001 EXT) mm 1637x898x750
Empty weight kg 140
Content of water l 32
Water manifold Ø 2”
Gas manifold Ø 1”
Flue manifold Ø mm 110
Condensate drain Ø mm 50
Power and Efficiency
Heat input ref. HHV (min ÷ max) kW 25,5 ÷ 127,8

MODULAR CONDENSING
Heat input ref. NHV (min ÷ max) kW 23 ÷ 115
Useful heat output (80°/60°C) kW 113,4

BOILERS
Useful heat output (50°/30°C) kW 124,9
Useful heat output (60°/40°C) kW 119,8
Condensate production per hour at 100% (50 - 30°C) - G20 kg/h 17,2
Useful efficiency ref. NHV (80°C/60°C) % 98,6
Useful efficiency ref. NHV (50°C/30°C) % 108,6
Useful efficiency ref. NHV Tm=50°C (60/40°C) % 104,2
Useful efficiency at 30% ref. NHV (80°C/60°C) % 99,2
Useful efficiency at 30% ref. NHV (50°C/30°C) % 109
Useful efficiency at 30% ref. NHV Tm=50°C (60 – 40°C) % 105
Losses through the casing (Tm=70°) % 0,1
Efficiency Class 92/42 CEE ++++
Consumption and electrical power
Gas category II2H3+
Gas consumption (G20) (min÷max) m3/h 2,43 ÷ 12,2
Power supply V - Hz 230 - 50
Maximum electrical power kW 0,25
Index of electrical protection IPX4D (for STAINLESS STEEL version only)
Combustion data
Max exhaust residual manometric head for each unit Pa 800
CO (0% di O2) (min ÷ max) mg/kWh 23 ÷ 130
NOx class 5
Heating circuit
Heating temperature regulation (min ÷ max) °C 20 ÷ 80
Water operating pressure (min ÷ max) bar (kPa) 6 ÷ 0,5 (600÷50)
Max manometric head at nominal flow of 5’500 l/h Pa [m c.a.] 1500 [1,5]
179
Modular floor-standing boilers for commercial applications
SPECIFIC ACCESSORIES FOR POWER PLUS BOX

Accessories for 500 series

REF. CODE DESCRIPTION

HYDRAULIC COMPONENTS FOR OUTDOOR INSTALLATION


1 20071791 Painted BOX empty
2 20071951 Hydraulic separator for BOX EXT max. 200 kW with fitting pipes (right)
3 20071950 Hydraulic separator for BOX EXT max. 200 kW with fitting pipes (left)
4 20071949 Hydraulic separator for BOX EXT max. 400 kW with fitting pipes (right)
5 20071943 Hydraulic separator for BOX EXT max. 400 kW with fitting pipes (left)
6 20071942 Hydraulic separator for BOX EXT max. 600 kW with fitting pipes (right)
7 20071940 Hydraulic separator for BOX EXT max. 600 kW with fitting pipes (left)
8 20010062 Hydraulic separator for BOX EXT max. 720 kW with fitting pipes (right)
9 20010065 Hydraulic separator for BOX EXT max. 720 kW with fitting pipes (left)
HYDRAULIC COMPONENTS FOR INDOOR INSTALLATION

10 20075000 Hydraulic separator for BOX INT max. 200 kW with fitting pipes (right)
11 20075001 Hydraulic separator for BOX INT max. 200 kW with fitting pipes (left)
12 20073125 Hydraulic separator for BOX INT max. 400 kW with fitting pipes (right)
13 20073126 Hydraulic separator for BOX INT max. 400 kW with fitting pipes (left)
14 20073304 Hydraulic separator for BOX INT max. 600 kW with fitting pipes (right)
15 20073305 Hydraulic separator for BOX INT max. 600 kW with fitting pipes (left)
16 20010996 Hydraulic separator for BOX INT max 720 kW with fitting pipes (right-left)

1 2 4 6 8 3 5 7 9

10 12 14 11 13 15 16

180
Modular floor-standing boilers for commercial applications
SPECIFIC ACCESSORIES FOR POWER PLUS BOX

Accessories for 500 series

REF. CODE DESCRIPTION

SAFETY DEVICES
Safety devices kit
17 20009475
(containing: temperature gauge, pressure gauge, pressure switch, connection plug with valve)
18 20009482 Gas shutting valve up to 230 kW (2”)
19 20009483 Gas shutting valve up to 580 kW (2”)
20 20011165 Gas shutting valve with flange up to 300 kW (1” ¼”)
21 20011167 Gas shutting valve with flange up to 540 kW (1” ½”)
22 20011169 Gas shutting valve with flange up to 720 kW (1” ¼”)

17 18 19 20 21 22

MODULAR CONDENSING
BOILERS

181
Modular floor-standing boilers for commercial applications
SPECIFIC ACCESSORIES FOR POWER PLUS BOX

Common accessories for 500 and 1000 series

REF. CODE DESCRIPTION

ELECTRICAL ACCESSORIES AND INTERFACES


23 1102379 Remote control kit for Power Plus
24 1103059 Probe kit for DHW tank
25 20016110 Zone master kit
26 20073129 Mod- Bus interface (cables included)
27 20046946 Kit USB interface
28 1102869 Low temperature kit

23 24 25 26

27 28

182
Modular floor-standing boilers for commercial applications
SPECIFIC ACCESSORIES FOR POWER PLUS BOX

Common accessories for 500 and 1000 series

REF. CODE DESCRIPTION

JUNCTION AND FLANGES KITS


29 20011126 Condensate neutralizer N2 (up to 320 kW)
30 20011132 Condensate neutralizer N3 (up to 1250 kW)
31 20011135 Condensate neutralizer HN2 , with pump (up to 320 kW)
32 20011162 Condensate neutralizer HN3 , with pump (up to 1250 kW)
33 20011003 Water anti-vibration kit (2 pcs.) DN 125 PN6
34 20011004 Gas anti-vibration kit (1 pcs.) DN 80 PN6
35 1102579 Blid flange 3” UNI 60/91 PN6 DN 80
36 1102589 Flange 3” UNI 2276-67 PN6 DN80
37 20063062 Hydraulic gasket 3” DN 80
38 20063060 Blind flange 5” UNI 60/91 PN6 DN125
39 20063061 Flange 5” UNI 2276-67 PN6 DN 125
40 20063063 Hydraulic gasket 5” DN 125
41 20063064 1 bolt and 1 nut (M 16x60)
42 20075887 Blind flanges kit
Power Plus junction kit for cascade (common to all BOXES 500-series except for
43 20074998
Power Plus LE 85 SYS and Power Plus LE HI 115 SYS)

29 30 31 32 33 34 35

MODULAR CONDENSING
BOILERS

36 37 38 39 40

41 42 43

Ø 50

Ø 160

x2 x2 x20

183
Inspectable plate heat exchangers
SP

Ŷ Inspectable plate heat-exchanger in stainless-steel AISI 316 L


Ŷ Gaskets in NBR
Ŷ Screw fittings in AISI 316
Ŷ Max working temperature 110°C
Ŷ Max pressure 10 bar

Plate heat exchangers DN 65

CODE MODEL PLATES no. DN MIX (%) * WEIGHT (kg)

20014230 SP 04A - 19 N 19 DN 65 100 122

20014218 SP 04A - 23 N 23 DN 65 100 124

20014225 SP 04X - 23 N 23 DN 65 45 126

20014219 SP 04A - 27 N 27 DN 65 100 126

20014239 SP 04X - 29 N 29 DN 65 40 100

20014238 SP 04X - 33 N 33 DN 65 35 130

20014235 SP 04A - 35 N 35 DN 65 100 131

20014234 SP 04X - 41 N 41 DN 65 35 135

20014232 SP 04A - 47 N 47 DN 65 100 142

20014236 SP 04X - 55 N 55 DN 65 35 147

20014231 SP 04A - 59 N 59 DN 65 100 150

20014241 SP 04X - 67 N 67 DN 65 90 155

20014233 SP 04X - 71 N 71 DN 65 25 157

20014228 SP 04X - 79 N 79 DN 65 85 177

20014221 SP 04X - 93 N 93 DN 65 20 186

* % mix of high-efficiency plates

184
Inspectable plate heat exchangers
SP

Dimensions - SP heat exchangers


L P
H W D
DESCRIPTION
mm mm mm

PLATE HEAT EXCHANGERS IN AISI 316 L, WITH NBR GASKETS

SP 04 - 19 to 71 N 820 310 638


H
SP 04 - 79 to 93 N 820 310 1138

SELECTION TABLE Condensing boilers / high temperature installations


Installation output Thermal software
POWER PLUS IN OUT LOSSES
CODE MODEL FLUID
CONFIGURATION (°C) (°C) (kPa)
100 - 115 20014230 SP04A-19N primary H2O 80 60 ≤ 15
150 20014230 SP04A-19N secondary H2O 50 70 ≤ 20
200 20014225 SP04A-23N
250 20014235 SP04A-35N
300 20014235 SP04A-35N
350 20014232 SP04A-47N
400 20014232 SP04A-47N
450 20014231 SP04A-59N
500 20014231 SP04A-59N

MODULAR CONDENSING
550 20014241 SP04X-67N

BOILERS
600 20014228 SP04X-79N

SELECTION TABLE Condensing boilers / low temperature installations


Installation output Thermal software
POWER PLUS IN OUT LOSSES
CODE MODEL FLUID
CONFIGURATION (°C) (°C) (kPa)
100 - 115 20014225 SP04X-23N primary H2O 60 40 ≤ 15
150 20014239 SP04X-29N secondary H2O 60 30 ≤ 15
200 20014238 SP04X-33N
250 20014234 SP04X-41N
300 20014236 SP04X-55N
350 20014233 SP04X-71N
400 20014233 SP04X-71N
450 20014221 SP04X-93N
500 20014221 SP04X-93N

185
186
HEAT PUMPS

HEAT PUMPS

187
DHW wall-hung heat pumps
ACQUAZENIT

Heat pump for domestic hot water production, wall mounted.


Heat pump operating air temp. from -7°C to 35°C
(ACQUAZENIT E 80 – E 120).
Heat pump operating air temp. from +7°C to 35°C
(ACQUAZENIT 80 – 120).
Combination of heat pump and back up electric heating
(electric heater included).
Rotation compressor on heat pump side.
Heat pump condenser wraps around DHW tank.
Legionella control function.
Built-in enamelled DHW tank with magnesium anode.
High insulation grade of the tank for low heat losses.
Easy and fast installation.
DHW temperature production up to 75°C.
TURBO mode for fast hot water production.
Diagnostic, alarms and hot water storage information.
Large display with touch screen.
Advanced electronic control with timing, temperatures and operating
mode selection.

Wall-hung DHW heat pumps

DIMENSIONS HEATING ENERGY CLASS


C.O.P.
CODE DESCRIPTION HXLXD CAPACITY
(50°)(1)
(mm) (kW)

20075566 ACQUAZENIT 80 1197 × 506 x 533 2.35 3,10

20075568 ACQUAZENIT 120 1497 × 506 x 533 2.35 3,10

20075569 ACQUAZENIT E 80 1197 × 506 x 533 2.35 3,10

20075571 ACQUAZENIT E 120 1497 × 506 x 533 2.35 3,10


(1)
Tair 15°C; Twater 10-55°C (EN 16147)

Note: Before installation, check the compatibility of weight and dimensions with the room and with the fixing system.

188
DHW wall-hung heat pumps
ACQUAZENIT

80 120
A 1197 1497 mm
B 345 645 mm
Net weight 58 65 kg
Weight 138 188 kg
with water

533
100 506
100

Technical specifications
DESCRIPTION 80 E80 120 E120
Tank capacity l 80 120
Rated pressure bar 6,00
Anti-corrosion protection of tank enamelled / Magnesium anode
Insulation thickness mm 40 - 85
Degree of protection IP 24
Max absorbed power W 2350
Power supply V-Hz 230-50
Number and electric heaters capacity W 2 X 1000
Electrical protection A 16
Water temperature set °C 55
Max water temperature (HP / electric heater) °C 55 / 75
Legionella control cycle °C 70
Air operating limits °C 7 -7 7 -7
Refrigerant type R134a
Refrigerant charge g 490 540 490 540
Heating time (1) h:min 4:40 6:40
Energy consumption during heating (1) kW 0,99 1,41
Type of measured cycle of emissions M
HEAT PUMPS

Energy consumption in the selected cycle of emissions (1) kW 2,04 2,08


COPDHW in the selected cycle of emissions (1) 3,10
Heating time (2) h:min 5:20 8:41
Energy consumption during heating (2) kW 1,12 1,78
Energy consumption in the selected cycle emissions (2) kW 2,45 2,51
COPDHW in the selected cycle of emissions (2) 2,65 2,61
Max available water (40 °C) l 90 142
Power INPUT in standby mode (according to EN16147) W 19 27
Sound power dB (A) 51
Sound pressure at 1m dB (A) 39,5
3
Air Flow m /h 100 - 230
Max available pressure drop in the pipeline (volumetric flow rate of air 100 m3/h) Pa 95
(1)
Tair 15 °C; Twater 10 - 55°C (EN 16147)
(2)
Tair 7 °C; Twater 10 - 55°C (EN 16147)

189
DHW floor-standing heat pumps
HP 260 ACS

Air-to-water heat pump for DHW production


3 models available:
- HP 260 ACS model with only heat pump.
- HP 260 ACS S: heat pump with an auxiliary coil for boiler or solar panels back-up.
- HP 260 ACS SC: heat pump with two auxiliary coils for both boiler and solar
panels back up.
Condenser externally wrapped to the boiler free from fouling and gas-water
contamination.
Tank in steel with two layers vitrification.
Thermal insulation with injected polyurethane with high thickness.
R134a refrigerant.
Built-in double-enamelled DHW tank (260 l capacity) with magnesium anode.
Electrical resistance provided as standard (1,5kW).
Easy installation and low noise performance.
Legionella cycle management through parameters.
Outdoor temperature sensor for automatic insertion of the resistance with
temperature not favorable to the heat pump.
Remote ON/OFF for complete unit (Timer).
Remote ON/OFF for electrical heater.
4 operating modes: STAND-BY, AUTOMATIC, MANUAL, ANTIBACTERICAL.

DHW floor-standing heat pumps


DIMENSIONS HEATING ENERGY CLASS
C.O.P.
CODE DESCRIPTION HxØ CAPACITY
(50°)(3)
(mm) (kW)

20072807 HP 260 ACS 1845 × 660 2.43 3,25

20072812 HP 260 ACS S 1845 × 660 2.43 3,25

20072813 HP 260 ACS SC 1845 × 660 2.43 3,25


(3)
Tair 15 C° - Twater 15 - 50 °C (EN 16147)

Accessories

CODE DESCRIPTION

20001492 Thermostatic mixing valve 1” with 3/4” adapter


20035644 Solar diverter valve
20009244 Control box SUN B with probes
1150489 18L expansion vessel*
20039876 160 Ø motorized damper kit
20047530 160 Ø air intake/expulsion grid
20047531 CMV ventilation kit
* Can be used on solar thermal, heating and DHW circuit.

190
DHW floor-standing heat pumps
HP 260 ACS
HP 260 ACS HP 260 ACS S HP 260 ACS SC

Technical specifications
HP ACS HP ACS S HP ACS SC
Tank capacity l 273 268 265
Surface auxiliary coil m2 - 1,5 0,6/1,5
Auxiliary coil water flow 80/60°C m3/h - 1,6 0,6/1,6
Domestic hot water production 80/60°C - 10/45°C (DIN 4708) m3/h - 1,1 0,4/1,1
Max working pressure tank bar 6
Max working pressure auxiliary coil bar 10
Power supply V/Ph/Hz 230/1/50
Max water temperature °C 60
Ambient Temperature (min/max) °C 8/32
Electric heater capacity W 1.500
Heating capacity W 2.427
Power input (average) (1) W 639
Refrigerant type R134a
Refrigerant charge g 1350
Noise level (2) dB(A) 52
C.O.P. (50°) (3) 3,25
Air flow m3/h 450
Available pressure head Pa 80
Max duct length m 10
Transport weight kg 112 127 145
A mm 1845 1845 1845
B mm 425 425 425
HEAT PUMPS

Ø mm 660 660 660


Ø C (Minimum duct diameter) mm 160 160 160
(1)
At max temperature: 60°
(2)
At 1 meter distance (free field not ducted)
(3)
Tair 15 C° - Twater 15-50 °C (EN 16147)

KEY DESCRIPTION KEY DESCRIPTION


1 Outlet hot water Rp 1” 7 Condensate drain Ø 20 mm
2 Outlet heating Rp 1” 8 Inlet cold water Rp 1
3 Recirculation Rp 1/2” 9 Electric heater Rp 1” 1/4
4 Inlet heating Rp 1” 10 Anode Rp 1” 1/4
5 Outlet solar Rp 1” 11 Probe socket control L=300mm Rp 1’’ 1/2
6 Inlet solar Rp 1” 12 Probe socket L=70mm Ø 12 mm

191
Hydronic reversible heat pumps
HYDRONIC UNIT LE

Air-to-water hydronic reversible heat pump with R410A.


Ideal solution for heating, cooling and domestic hot water production.
Low Energy circulator provided as standard.
DC-inverter technology with twin rotary compressor (4 kW rotary).
High COP and EER.
Wide operating limits: -20°C in heating and +46°C in cooling.
Water heating temperature up to +60°C.
Advanced remote control provided as standard.
Possibility to produce DHW through external 3-ways valve.
Electronic expansion valve
Expansion vessel provided as standard.
Plug and play units with very compact dimensions.
Low noise units.

Single-phase heat pumps

DIMENSIONS RATED CAPACITY ENERGY EFFICIENCY


CODE DESCRIPTION HxLxD CLASS COP (1)/ EER (7)
HEATING(1)/COOLING(7)
(mm) (kW) 55°C 35°C

20099402 HYDRONIC UNIT LE 4 821 x 908 x 326 4.07 / 4.93 4,15 / 4,20

20099403 HYDRONIC UNIT LE 6 821 x 908 x 326 5.76 / 7.04 4,28 / 3,70

20099404 HYDRONIC UNIT LE 8 821 x 908 x 326 7.16 / 7.84 3,97 / 3,99

20099405 HYDRONIC UNIT LE 12 1363 x 908 x 326 11.86 / 13.54 3,95 / 3,66

20099406 HYDRONIC UNIT LE 15 1363 x 908 x 326 14.46 / 16.04 4,09 / 3,85

(1) outside air d.b.+7°C/w.d.+6°C, water 30/35°C


(7) outside air d.b.+35°C/w.b.+24°C, water 23°C/18°C

Three-phase heat pumps

DIMENSIONS RATED CAPACITY ENERGY EFFICIENCY COP (1)/ EER (7)


CLASS
CODE DESCRIPTION HxLxD HEATING(1)/COOLING(7)
(mm) (kW) 55°C 35°C

20099407 HYDRONIC UNIT LE 12T 1363 x 908 x 326 12.00 / 13.50 4,30 / 4,15

20099408 HYDRONIC UNIT LE 15T 1363 x 908 x 326 15.00 / 16.00 4,20 / 3,81

(1) outside air d.b.+7°C/w.d.+6°C, water 30/35°C


(7) outside air d.b.+35°C/w.b.+24°C, water 23°C/18°C

192
Hydronic reversible heat pumps
HYDRONIC UNIT LE

Accessories

CODE DESCRIPTION

20028567 Outdoor ambient temperature sensor (OAT)


Note: Hydronic Unit LE can be matched with STOR H range.

Technical specifications

HYDRONIC HYDRONIC HYDRONIC HYDRONIC HYDRONIC HYDRONIC HYDRONIC


DESCRIPTION
UNIT LE 4 UNIT LE 6 UNIT LE 8 UNIT LE 12 UNIT LE 15 UNIT LE 12T UNIT LE 15T
HEATING PERFORMANCE
Rated capacity (1) kW 4,07 5,76 7,16 11,86 14,46 12,00 15,00
COP (1) 4,15 4,28 3,97 3,95 4,09 4,30 4,20
Absorbed power (1) kW 0,98 1,35 1,80 3,00 3,54 2,79 3,57
Rated capacity (2) kW 3,87 5,76 7,36 12,91 13,96 11,20 14,50
COP (2) 3,26 3,05 3,19 3,03 3,23 3,35 3,30
Absorbed power (2) kW 1,19 1,89 2,31 4,26 4,32 3,34 4,39
Rated capacity (3) kW 4,27 5,43 7,25 10,89 12,36 11,43 12,17
COP (3) 2,92 2,77 2,81 2,68 3,02 3,12 2,98
(3)
Absorbed power kW 1,46 1,95 2,58 4,05 4,09 3,66 4,08
COP seasonal (3) 3,53 3,37 2,84 2,95 3,25 3,47 3,33
Energy efficiency class (3) A++ A++ A+ A+ A++ A++ A++
(average climate conditions-tempered zone)

COOLING PERFORMANCE
Rated capacity (6) kW 3,33 4,73 5,84 10,24 13,04 10,20 13,00
Absorbed power (6) kW 1,10 1,58 1,96 3,46 4,42 3,40 4,47
EER (6) 3,02 3,00 2,98 2,96 2,95 3,00 2,91
Rated capacity (7) kW 4,93 7,04 7,84 13,54 16,04 13,50 16,00
Absorbed power (7) kW 1,17 1,90 1,96 3,70 4,17 3,25 4,20
EER (7) 4,20 3,70 3,99 3,66 3,85 4,15 3,81
ESEER (6) 4,36 4,51 4,15 4,22 4,31 4,4 4,31
GENERAL INFORMATION
Sound power dB(A) 62 62 64 67 68 68 68
Compressor Rotary DC Inv. Twin Rotary DC Inverter Tecnology
Refrigerant charge R410a * kg 1,195 1,35 1,81 2,45 3,39 2,45 3,385
Empty weight kg 57 61 69 104 112 116 116
HYDRAULIC CIRCUIT
HEAT PUMPS

Expansion tank capacity l 2 2 2 3 3 3 3


Expansion tank precharge kPa 100 100 100 100 100 100 100
Minimum water volume content l 14 21 28 42 49 42 49
Maximum water volume content ** l 65 65 65 95 95 95 95
Plate heat exchanger water content l 0,8 0,8 1,0 2,3 2,3 2,3 2,3
Maximum working pressure kPa 300 300 300 300 300 300 300
Minimum filling pressure kPa 120 120 120 120 120 120 120
Water connections Diameter inches 1M 1M 1M 1M 1M 1M 1M
* The value of the refrigerant charge is indicative. The correct value is indicated on the technical data plate.
** For greater water volumes it is necessary to provide an additional expansion tank.

(1) Outside air d.b.+7°C/w.b.+6°C, water 30/35°C


(2) Outside air d.b.+7°C/w.b.+6°C, water 40/45°C
(3) Outside air d.b.+7°C/w.b.+6°C, water 47/55°C
(6) Outside air d.b.+35°C, water 7/12°C
(7) Outside air d.b.+35°C/w.b.+24°C, water 18/23°C
d.b.= dry bulb / w.b.= wet bulb
193
Hydronic reversible heat pumps
HYDRONIC UNIT LE

Technical drawings and overall dimensions

HYDRONIC UNIT LE 4
HYDRONIC UNIT LE 6
HYDRONIC UNIT LE 8

HYDRONIC UNIT LE 12/12T


HYDRONIC UNIT LE 15/15T

194
Hydronic reversible heat pumps
HYDRONIC UNIT LE

Operating limits

COOLING HEATING
20 70

18 65
006 60
16
004 55
14
50
12 45
B 10 B 40

8 35
30
6
008-012-015 25
4
20
2 15
0 10
-5 0 5 10 15 20 25 30 35 40 45 50 -25 -20 -15 -10 -5 0 5 10 15 20 25 30 35

A A
- A Outdoor temperature (°C)
- B Output water temperature (°C)

Available static pressure

4 6
75 75
65 65
55 55

B 45 B 45
35 35
25 25
15 15
5 5
0,0 0,1 0,2 0,3 0,4 0,5 0,0 0,1 0,2 0,3 0,4 0,5 0,6
A A

8 12 - 15
75 95
65 85
HEAT PUMPS

75
55
65
45
B B 55
35
45
25 35
15 25
5 15
0,0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1,0
A A

Flow-rate and pressure head diagram


- A Flow rate (l/s)
- B Available static pressure (kPa)

195
Buffer tanks for systems with heat pumps
STOR H

Inertial cold/hot water buffer tank, ideal to be used in systems with


heat pumps, solar thermal, biomass boilers.
It can be easily fitted into systems where Beretta boilers work as an
auxiliary heat generator.
The fittings are positioned at different heights for use in high and low
temperature circuits.
Possibility to integrate an electrical resistance.

Inertial cold/hot water buffer tank


DHW
DIMENSIONS STORAGE ENERGY CLASS
HEAT LOSS
CODE DESCRIPTION HxØ VOLUME
(W)
(mm) (litres)

20056180 STOR H 200 1395 × 550 203 68

20056181 STOR H 300 1560 × 600 277 82

20056182 STOR H 400 1540 × 700 390 105

20056183 STOR H 500 1840 × 700 473 129

Accessories

CODE DESCRIPTION

4383270 Single-phase electrical resistance kit 1,5 kW, 1” 1/2


4383271 Single-phase electrical resistance kit 2,2 kW, 1” 1/2
4383272 Single-phase electrical resistance kit 3 kW, 1” 1/2
20020707 Three-phase electrical resistance kit 3,8 kW, 1” 1/2

196
Buffer tanks for systems with heat pumps
STOR H

Mod. 200 - 300 - 400 Mod. 500


1 2 1 2

Mod. 200 - 300 - 400 Mod. 500

MC MI MC
MI
MI X MC
3 3
MI X MC

4 4
Z MI
Z MI X MC
X 3 3 MC
D D

C E C E

RI 3 RC
RI 3 RC
RI X RC RI X RC SC SC
B B
SC SC
A A

5 5

Technical specifications
DESCRIPTION STOR H 200 STOR H 300 STOR H 400 STOR H 500
Buffer tank type Not enamelled
Buffer tank lay-out Vertical
Storage volume l 203 277 390 473
External diameter with insulation mm 550 600 700 700
Height with insulation mm 1395 1560 1540 1840
Insulation thickness mm 50
Tank maximum working pressure bar 6
Tank maximum working temperature °C 99
Heat losses W 68 82 105 129
Net weigth with insulation kg 45 55 95 95
H - Height mm 1395 1560 1540 1840
Ø - Diameter mm 550 600 700 700
Gross weight (package included) kg 64 75 116 118
1 - Insulation (polyurethane) mm 50
2 - Vent valve fitting Ø 1’’ 1/4 F
3 - Probe sockets diameter Ø 1/2’’ F
4 - Sleeve for electric heating element (not supplied) Ø 1’’ 1/2 F
5 - Buffer tank -
MI - CH Flow Ø 1’’ 1/2 F 2’’ F 2’’ 1/2 F 2’’ 1/2 F
RI - CH Return Ø 1’’ 1/2 F 2’’ F 2’’ 1/2 F 2’’ 1/2 F
SC - Drain Ø 1/2’’ F 3/4’’ F 3/4’’ F 3/4’’ F
RC - Boiler Return Ø 1’’ 1/2 F 2’’ F 2’’ 1/2 F 2’’ 1/2 F
MC - Boiler Flow Ø 1’’ 1/2 F 2’’ F 2’’ 1/2 F 2’’ 1/2 F
HEAT PUMPS

Z - Electrical heater fitting


X - Probes sockets
A mm 105 120 135 135
B mm 215 235 240 240
C mm 705 785 775 925
D mm 1200 1340 1310 1610
E mm 750 830 820 970

197
198
SOLAR THERMAL

SOLAR THERMAL

199
Forced circulation systems
FKB-SOL - Systems with flat collectors SCF-25B and IDRA FI-LE cylinder

A SCF-25B collector with sealed aluminium frame - 2,5 m2.


C
B IDRA FI-LE cylinder with pre-installed flow/return hydraulic
group, featuring a Low Energy modulating circulator, and
D SUN B solar controller.
B
C Glycol.
D Solar expansion vessel.
E Flexible pipe kit for expansion vessel.
F Thermostatic mixing valve 3/4”.
A
E

Systems for flat and pitched roof - Brackets not included

CYLINDER COLLECTORS COLLECTORS


NUMBER OF
CODE MODEL CAPACITY DIMENSIONS TOTAL AREA
COLLECTORS
(litres) H X L (mm) (m2)
SYSTEMS WITH SINGLE COIL CYLINDER

20099138 FKB-SOL 150M/1 1 150 single coil 2.003 x 1.195 2,30

SYSTEMS WITH DOUBLE COIL CYLINDER

CYLINDER COLLECTORS COLLECTORS


NUMBER OF
CODE MODEL CAPACITY DIMENSIONS TOTAL AREA
COLLECTORS
(litres) H X L (mm) (m2)

20096251 FKB-SOL 200/1 1 205 double coil 2.003 x 1.195 2,30

20096252 FKB-SOL 300/2 2 296 double coil 2.003 x 2.390 4,60

20099139 FKB-SOL 400/3 3 441 double coil 2.003 x 3.585 6,90

20099140 FKB-SOL 500/4 4 550 double coil 2.003 x 4.780 9,20

To complete the installation it is necessary to buy, according to the number of collectors and to the kind of roof and installation, complete brackets kits for flat or pitched
roof or undertile brackets kits.
N.B. The manual air vent (code 20026577) is not included in the FKB-SOL and F2B-SOL systems.
N.B. Please check the twin coils cylinder section for the model of the electrical resistance suitable for this kind of systems.

200
Forced circulation systems
FKB-SOL - BRACKETS complete kits

Brackets for PITCHED ROOF - complete kits for FKB-SOL systems

CODE DESCRIPTION

20099171 Brackets kit for PITCHED ROOF - 1 SCF-25B collector


20099172 Brackets kit for PITCHED ROOF - 2 SCF-25B collectors
20099173 Brackets kit for PITCHED ROOF - 3 SCF-25B collectors
20099174 Brackets kit for PITCHED ROOF - 4 SCF-25B collectors

Undertile brackets for PITCHED ROOF - complete kits for FKB-SOL systems

CODE DESCRIPTION

20099177 Undertile brackets kit for PITCHED ROOF - 1 SCF-25B collector


20099178 Undertile brackets kit for PITCHED ROOF - 2 SCF-25B collectors
20099179 Undertile brackets kit for PITCHED ROOF - 3 SCF-25B collectors
20099180 Undertile brackets kit for PITCHED ROOF - 4 SCF-25B collectors

Brackets for FLAT ROOF - complete kits for FKB-SOL systems

CODE DESCRIPTION

20099187 Brackets kit for FLAT ROOF - 1 SCF-25B collector


20099188 Brackets kit for FLAT ROOF - 2 SCF-25B collectors
20099189 Brackets kit for FLAT ROOF - 3 SCF-25B collectors
20099190 Brackets kit for FLAT ROOF - 4 SCF-25B collectors

The ending fittings for the connection of Ø 22 copper pipes (code 20014661), containing weld-on fittings, to be put at the collector inlet-outlet, and screw-on fittings, to be
put at the inlet/outlet of hydraulic group/solar cylinder, are available separately. For the composition of brackets kit refer to SCF-25B dedicated section.
The ending fittings for the connection of stainless-steel flexible pipes (code 20001452) containing weld-on fittings, to be put at the collector inlet-outlet, and screw-on fit-
tings, to be put at the inlet/outlet of hydraulic group/solar cylinder, are available separately. For the composition of brackets kit refer to SCF-25B dedicated section.
SOLAR THERMAL

As an alternative, it is possible to use the code 20108734 “female ending fitting kit” in order to have, at the two collectors ends, a female connection. For the composition
of brackets kit refer to SCF-25B dedicated section.

201
Forced circulation systems
FKB-SOL- systems composition

FKB-SOL 150M/1 (code 20099138)

REF. QUANTITY CODE DESCRIPTION

A 1 20095375 1 SCF-25B collector


B 1 20096928 Single coil cylinder IDRA MS 150 FI - LE (D class)
C 1 1150549 Glycol 5 kg
D 1 1150489 18 litres solar expansion vessel
E 1 1150499 Flexible pipe kit for expansion vessel
F 1 1150529 Thermostatic mixing valve 3/4”

FKB-SOL 200/1 (code 20096251)

REF. QUANTITY CODE DESCRIPTION

A 1 20095375 1 SCF-25B collector


B 1 20096929 Double coil cylinder IDRA DS 200 FI - LE (C class)
C 1 1150559 Glycol 10 kg
D 1 1150489 18 litres solar expansion vessel
E 1 1150499 Flexible pipe kit for expansion vessel
F 1 1150529 Thermostatic mixing valve 3/4”

FKB-SOL 300/2 (code 20096252)

REF. QUANTITY CODE DESCRIPTION

A 1 20095376 2 pcs SCF-25B collector (in 1 package)


B 1 20096930 Double coil cylinder IDRA DS 300 FI - LE (B class)
C 1 1150559 Glycol 10 kg
D 1 1150489 18 litres solar expansion vessel
E 1 1150499 Flexible pipe kit for expansion vessel
F 1 1150529 Thermostatic mixing valve 3/4”

202
Forced circulation systems
FKB-SOL- systems composition

FKB-SOL 400/3 (code 20099139)

REF. QUANTITY CODE DESCRIPTION

A 1 20095375 1 SCF-25B collector


A 1 20095376 2 pcs SCF-25B collector (in 1 package)
B 1 20096931 Double coil cylinder IDRA DS 430 FI - LE (B class)
C 1 1150549 Glycol 5 kg
C 1 1150559 Glycol 10 kg
D 1 1150509 24 litres solar expansion vessel
E 1 1150499 Flexible pipe kit for expansion vessel
F 1 1150529 Thermostatic mixing valve 3/4”

FKB-SOL 500/4 (code 20099140)

REF. QUANTITY CODE DESCRIPTION

A 2 20095376 4 pcs SCF-25B collector (in 2 packages)


B 1 20096932 Double coil cylinder IDRA DS 550 FI - LE
C 2 1150559 Glycol 10 kg
D 1 1150519 35 litres solar expansion vessel
F 1 1150529 Thermostatic mixing valve 3/4”

To complete the installation it is necessary to buy, according to the number of collectors and to the kind of roof and installation, complete brackets kits for flat or pitched
roof or undertile brackets kits.
SOLAR THERMAL

203
Forced circulation systems
F2B-SOL - Systems with flat collectors SCF-20B and IDRA cylinder

A SCF-20B collector with sealed aluminium frame - 2 m2.


B
B Solar control box SUN B.
D
C IDRA cylinder with increased coil surface.
D Solar hydraulic return group with Low Energy modulating
C
circulator.
E Connection kit for pump station with cylinder.
E
F Glycol.
G Solar expansion vessel.
A H Thermostatic mixing valve 3/4”.
F

Systems for flat and pitched roof - Brackets not included

CYLINDER COLLECTORS COLLECTORS


NUMBER OF
CODE MODEL CAPACITY DIMENSIONS TOTAL AREA
COLLECTORS
(litres) H X L (mm) (m2)
SYSTEMS WITH SINGLE COIL CYLINDER

20099064 F2B-SOL 150M/1 1 150 single coil 1.818 x 1.097 1,91

SYSTEMS WITH DOUBLE COIL CYLINDER

CYLINDER COLLECTORS COLLECTORS


NUMBER OF
CODE MODEL CAPACITY DIMENSIONS TOTAL AREA
COLLECTORS
(litres) H X L (mm) (m2)

20099069 F2B-SOL 200/1 1 205 double coil 1.818 x 1.097 1,91

20099107 F2B-SOL 300/2 2 296 double coil 1.818 x 2.194 3,82

20099108 F2B-SOL 400/3 3 441 double coil 1.818 x 3.291 5,73

20099109 F2B-SOL 500/4 4 550 double coil 1.818 x 4.388 7,64

To complete the installation it is necessary to buy, according to the number of collectors and to the kind of roof and installation, complete brackets kits for flat or pitched
roof or undertile brackets kits.
N.B. The manual air vent (code 20026577) is not included in the FKB-SOL and F2B-SOL systems.
N.B. Please check the twin coils cylinder section for the model of the electrical resistance suitable for this kind of systems.

204
Forced circulation systems
F2B-SOL - BRACKETS complete kits

Brackets for PITCHED ROOF - complete kits for F2B-SOL systems

CODE DESCRIPTION

20099142 Brackets kit for PITCHED ROOF - 1 SCF-20B collector


20099143 Brackets kit for PITCHED ROOF - 2 SCF-20B collectors
20099144 Brackets kit for PITCHED ROOF - 3 SCF-20B collectors
20099145 Brackets kit for PITCHED ROOF - 4 SCF-20B collectors

Undertile brackets for PITCHED ROOF - complete kits for F2B-SOL systems

CODE DESCRIPTION

20099149 Undertile brackets kit for PITCHED ROOF - 1 SCF-20B collector


20099150 Undertile brackets kit for PITCHED ROOF - 2 SCF-20B collectors
20099151 Undertile brackets kit for PITCHED ROOF - 3 SCF-20B collectors
20099152 Undertile brackets kit for PITCHED ROOF - 4 SCF-20B collectors

Brackets for FLAT ROOF - complete kits for F2B-SOL systems

CODE DESCRIPTION

20099159 Brackets kit for FLAT ROOF - 1 SCF-20B collector


20099160 Brackets kit for FLAT ROOF - 2 SCF-20B collectors
20099163 Brackets kit for FLAT ROOF - 3 SCF-20B collectors
20099164 Brackets kit for FLAT ROOF - 4 SCF-20B collectors

The ending fittings for the connection of Ø 22 copper pipes (code 20014661), containing weld-on fittings, to be put at the collector inlet-outlet, and screw-on fittings, to be
put at the inlet/outlet of hydraulic group/solar cylinder, are available separately. For the composition of brackets kit refer to SCF-20B dedicated section.
The ending fittings for the connection of stainless-steel flexible pipes (code 20001452) containing weld-on fittings, to be put at the collector inlet-outlet, and screw-on fit-
SOLAR THERMAL

tings, to be put at the inlet/outlet of hydraulic group/solar cylinder, are available separately. For the composition of brackets kit refer to SCF-20B dedicated section.
As an alternative, it is possible to use the code 20108734 “female ending fitting kit” in order to have, at the two collectors ends, a female connection. For the composition
of brackets kit refer to SCF-25B dedicated section.

205
Forced circulation systems
F2B-SOL - systems composition

F2B-SOL 150M/1 (code 20099064)

REF. QUANTITY CODE DESCRIPTION

A 1 20095379 1 SCF-20B collector


B 1 20009244 Solar control box SUN B
C 1 20072887 Single coil cylinder IDRA MS 150 (D class)
D 1 20096925 Solar hydraulic return group with Low Energy modulating circulator
E 1 20027382 Connection kit for pump station with cylinder
F 1 20009190 Glycol 2,5 kg
G 1 1150489 18 litres solar expansion vessel
H 1 1150529 Thermostatic mixing valve 3/4”

F2B-SOL 200/1 (code 20099069)

REF. QUANTITY CODE DESCRIPTION

A 1 20095379 1 SCF-20B collector


B 1 20009244 Solar control box SUN B
C 1 20001224 Double coil cylinder IDRA DS 200 (C class)
D 1 20096925 Solar hydraulic return group with Low Energy modulating circulator
E 1 20027382 Connection kit for pump station with cylinder
F 1 1150549 Glycol 5 kg
G 1 1150489 18 litres solar expansion vessel
H 1 1150529 Thermostatic mixing valve 3/4”

F2B-SOL 300/2 (code 20099107)

REF. QUANTITY CODE DESCRIPTION

A 1 20095380 2 pcs SCF-20B collector (in 1 package)


B 1 20009244 Solar control box SUN B
C 1 20001225 Double coil cylinder IDRA DS 300 (B class)
D 1 20096925 Solar hydraulic return group with Low Energy modulating circulator
E 1 20027382 Connection kit for pump station with cylinder
F 1 1150549 Glycol 5 kg
G 1 1150489 18 litres solar expansion vessel
H 1 1150529 Thermostatic mixing valve 3/4”

206
Forced circulation systems
F2B-SOL - systems composition

F2B-SOL 400/3 (code 20099108)

REF. QUANTITY CODE DESCRIPTION

A 1 20095379 1 SCF-20B collector


A 1 20095380 2 pcs SCF-20B collector (in 1 package)
B 1 20009244 Solar control box SUN B
C 1 20001226 Double coil cylinder IDRA DS 430 (B class)
D 1 20096925 Solar hydraulic return group with Low Energy modulating circulator
E 1 20027382 Connection kit for pump station with cylinder
F 1 20009190 Glycol 2,5 kg
F 1 1150559 Glycol 10 kg
G 1 1150509 24 litres solar expansion vessel
H 1 1150529 Thermostatic mixing valve 3/4”

F2B-SOL 500/4 (code 20099109)

REF. QUANTITY CODE DESCRIPTION

A 2 20095380 4 pcs SCF-20B collector (in 2 packages)


B 1 20009244 Solar control box SUN B
C 1 20001227 Double coil cylinder IDRA DS 550
D 1 20096925 Solar hydraulic return group with Low Energy modulating circulator
E 1 20027382 Connection kit for pump station with cylinder
F 1 1150549 Glycol 5 kg
F 1 1150559 Glycol 10 kg
G 1 1150509 24 litres solar expansion vessel
H 1 1150529 Thermostatic mixing valve 3/4”

To complete the installation it is necessary to buy, according to the number of collectors and to the kind of roof and installation, complete brackets kits for flat or pitched
roof or undertile brackets kits.
SOLAR THERMAL

207
Solar thermal
PRODUCT MATRIX OF BERETTA SOLAR COLLECTORS

ABSORBER
DESCRIPTION INSTALLATION STRUCTURE
FEATURES

aluminium with
SCF-V25
vertical aluminium tray high selective coating
(2,5m2)
(TiNOx Energy Al)

SCF-25B aluminium with


vertical sealed aluminium frame high selective coating
(2,5m2) (TiNOx Energy Al)
FLAT PLATE

SCF-20B aluminium with


vertical sealed aluminium frame high selective coating
(2m2) (TiNOx Energy Al)

SCO-25B aluminium with


horizontal sealed aluminium frame high selective coating
(2,5m2) (TiNOx Energy Al)
FLAT PLATE

aluminium with
INSET

SCI-25N
vertical wooden frame high selective coating
(2,5m2)
(TiNOx Energy Al)
VACUUM

14 vacuum double-walled glass Sydney tubes


TUBE

SCV-25
vertical mechanically fixed to an aluminium
(2,5m2)
circumferential absorber

208
TOTAL AREA / IAM (50°) COLLECTOR
EXCHANGER FITTINGS Incidence of Angle PACKAGES
EXPOSED AREA Modifier EFFICIENCY (%)

harp-shaped
2,57 / 2,3 m2 (M)-(F) 1” 0,85 60 ƾcol (*) 1pc - 2pcs - 5pcs
copper pipes

harp-shaped
2,30 / 2,16 m2 (M)-(F) 1” 0,96 61 ƾcol (*) 1pc - 2pcs - 5pcs
copper pipes

harp-shaped
1,91 / 1,78 m2 (M)-(F) 1” 0,87 58 ƾcol (*) 1pc - 2pcs - 7pcs
copper pipes

harp-shaped
2,30 / 2,16 m2 (M)-(M) 1” 0,93 59,2 ƾcol (*) 1pc - 5pcs
copper pipes

harp-shaped
2,40 / 2,2 m2 (F)-(F) 1” 0,92 59 ƾcol (*) 1pc - 2pcs - 7pcs
copper pipes

U-shaped T 1,07
2,77 / 2,4 m2 2 x Ø18mm 64 ƾcol (*) 1pc
copper pipes L 0,954

(*) Calculated with total solar radiation of 1.000 W/m2


SOLAR THERMAL

209
Collectors for forced circulation systems
SCF-V25 - TRAY COLLECTOR - 2,5m2

Ŷ Tray collector - 2,5 m2.


Ŷ Highly selective finish of the absorber surface.
Ŷ Complete with anti-irradiation film to be taken away at the activation of
the system.
Ŷ Prismatic solar glass with double anti-reflective treatment.
Ŷ Insulation in thick rock wool on the rear side (50 mm) and on the
SOLAR lateral side (9 mm).
KEYMARK Ŷ Collector stagnation temperature: 201 °C.
Ŷ Collector absorption: 95%.
certification
Ŷ Possibility to connect up to 6 collectors in series.
Ŷ Solar collector conforms to the EN 12975 standard.
Ŷ Connection between collectors by means of 2 floating couplings.

Tray collector - 2,5 m2

DIMENSIONS COLLECTOR
CODE MODEL H×Ø TOTAL AREA
(mm) (m2)

20050314 SCF-V25 2.078 x 1.240 2,57

Packages

CODE MODEL

20050316 One package containing 2 pcs of code 20050314 SCF-V25

20050317 One package containing 5 pcs of code 20050314 SCF-V25

210
Collectors for forced circulation systems
SCF-V25 - TRAY COLLECTOR - 2,5m2
1265
1240 100

83
Collector Ventilation holes
Collector
outlet return

Collector
probe
socket

Aluminium tray
2078

4 mm anti-reflective glass

Connection 1”
Flow direction
of the heat
transfer liquid

Collector ø 22 mm
Lateral insulation 9 mm
Rear insulation 50 mm

Technical specifications

DESCRIPTION TRAY COLLECTOR SCF-V25 UOM

Total area 2,57 m2


Exposed area 2,30 m2
Effective absorption area 2,15 m2
Connections (M) - (F) 1” -
Weight (empty) 45 kg
Liquid content 1,6 l
Recommended flow rate for 1 m2 collector 30 l/h
Anti-reflective glass thickness 4 mm
Absorption (Į) ~95 %
Emissions (İ 4 %
IAM (50°) 0,85 -
Ș coll. (at 1000 W/m2) 60 %
Maximum permitted pressure 10 bar
Stagnation temperature 201 °C

Efficiency curve Head loss in solar collector (*)


1 140

120
0,8
100
Head loss (mbar)

0,6
SOLAR THERMAL

80

0,4 60

40
0,2
20

0 0
0 0,02 0,04 0,06 0,08 0,1 0,12 0 100 200 300 400 500 600 700 800 900 1000
Tm[m2K/W] Flow rate (l/h)

(*) Test referred to a glycol-water mixture (33,3% - 67,7%), with 20 °C temperature of the heat-transfer fluid.

211
Collectors for forced circulation systems
SCF-V25 - BRACKETS complete kits

Brackets for PITCHED ROOF - complete kits for SCF-V25 collector

CODE DESCRIPTION

20055502 Brackets kit for PITCHED ROOF - 1 SCF-V25 collector


20055503 Brackets kit for PITCHED ROOF - 2 SCF-V25 collectors
20055504 Brackets kit for PITCHED ROOF - 3 SCF-V25 collectors
20055509 Brackets kit for PITCHED ROOF - 4 SCF-V25 collectors
20055505 Brackets kit for PITCHED ROOF - 5 SCF-V25 collectors
20055506 Brackets kit for PITCHED ROOF - 6 SCF-V25 collectors

Undertile brackets for PITCHED ROOF - complete kits for SCF-V25 collector

CODE DESCRIPTION

20055511 Undertile brackets kit for PITCHED ROOF - 1 SCF-V25 collector


20055512 Undertile brackets kit for PITCHED ROOF - 2 SCF-V25 collectors
20055513 Undertile brackets kit for PITCHED ROOF - 3 SCF-V25 collectors
20055514 Undertile brackets kit for PITCHED ROOF - 4 SCF-V25 collectors
20055515 Undertile brackets kit for PITCHED ROOF - 5 SCF-V25 collectors
20055516 Undertile brackets kit for PITCHED ROOF - 6 SCF-V25 collectors

Brackets for FLAT ROOF - complete kits for SCF-V25 collector

CODE DESCRIPTION

20055493 Brackets kit for FLAT ROOF - 1 SCF-V25 collector


20055495 Brackets kit for FLAT ROOF - 2 SCF-V25 collectors
20055496 Brackets kit for FLAT ROOF - 3 SCF-V25 collectors
20055497 Brackets kit for FLAT ROOF - 4 SCF-V25 collectors
20055498 Brackets kit for FLAT ROOF - 5 SCF-V25 collectors
20055499 Brackets kit for FLAT ROOF - 6 SCF-V25 collectors

The detailed composition of the complete brackets kits can be found in the composition tables of the following pages.

212
Collectors for forced circulation systems
SCF-V25 - COMPOSITION TABLE of BRACKETS KITS for PITCHED ROOF

Brackets - primary codes for SCF-V25 collector

REF. CODE DESCRIPTION

A 4383540 Supporting bars kit for 1 SCF-V25


B 4383541 Supporting bars kit for 2 SCF-V25
C 4383542 Supporting bars kit for 3 SCF-V25
D 20008292 Fixing elements kit for PITCHED ROOF
E 20008757 Coupling joint kit
F 20014661 Ending connection fittings kit for 2,5 m2 collector**

Composition table* of complete brackets kits for PITCHED ROOF for SCF-V25 collector

20055502 20055503 20055504 20055509 20055505 20055506


REF. CODE DESCRIPTION kit for 1 kit for 2 kit for 3 kit for 4 kit for 5 kit for 6
collector collectors collectors collectors collectors collectors
A 4383540 Supporting bars kit for 1 SCF-V25 1 - - - - -
B 4383541 Supporting bars kit for 2 SCF-V25 - 1 - 2 1 -
C 4383542 Supporting bars kit for 3 SCF-V25 - - 1 - 1 2
D 20008292 Fixing elements for PITCHED ROOF 2 2 3 5 6 7
E 20008757 Coupling joint kit - - - 1 1 1
Ending connection fittings kit for
F 20014661 1 1 1 1 1 1
2,5 m2 collector**
* This composition table must be read in vertical sense.
** The code 20014661 (ending connection fittings kit for 2,5 m2 collector), ref. F, contains the fittings for connection to copper pipes Ø 22 mm to be put at the inlet-outlet
of the collectors series and the fittings to be inserted at the outlet of the cylinder or of the flow-return hydraulic group.

A B C D E F

M12 M12 M8
FOR COLLECTOR
4x 6x 4x
M8 x 20
SOLAR THERMAL

FOR SOLAR CYLINDER


2x 2x 4x

213
Collectors for forced circulation systems
SCF-V25 - COMPOSITION TABLE of UNDERTILE BRACKETS KITS for PITCHED ROOF

Undertile Brackets - primary codes for SCF-V25 collector

REF. CODE DESCRIPTION

A 4383540 Supporting bars kit for 1 SCF-V25


B 4383541 Supporting bars kit for 2 SCF-V25
C 4383542 Supporting bars kit for 3 SCF-V25
D 20013464 Undertile fixing elements kit for PITCHED ROOF
E 20008757 Coupling joint kit
F 20014661 Ending connection fittings kit for 2,5 m2 collector**

Composition table* of complete undertile brackets kits for PITCHED ROOF for SCF-V25 collector

20055511 20055512 20055513 20055514 20055515 20055516


REF. CODE DESCRIPTION kit for 1 kit for 2 kit for 3 kit for 4 kit for 5 kit for 6
collector collectors collectors collectors collectors collectors
A 4383540 Supporting bars kit for 1 SCF-V25 1 - - - - -
B 4383541 Supporting bars kit for 2 SCF-V25 - 1 - 2 1 -
C 4383542 Supporting bars kit for 3 SCF-V25 - - 1 - 1 2
Undertile fixing elements kit
D 20013464 2 2 3 5 6 7
for PITCHED ROOF
E 20008757 Coupling joint kit - - - 1 1 1
Ending connection fittings kit for
F 20014661 1 1 1 1 1 1
2,5 m2 collector**

* This composition table must be read in vertical sense.


** The code 20014661 (ending connection fittings kit for 2,5 m2 collector), ref. F, contains the fittings for connection to copper pipes Ø 22 mm to be put at the inlet-outlet
of the collectors series and the fittings to be inserted at the outlet of the cylinder or of the flow-return hydraulic group.

A B C D E F
M8

2x 4x M8 x 20 FOR COLLECTOR

M12 M12

4x 4x 4x
FOR SOLAR CYLINDER

214
Collectors for forced circulation systems
SCF-V25 - COMPOSITION TABLE of BRACKETS KITS for FLAT ROOF

Brackets - primary codes for SCF-V25 collector

REF. CODE DESCRIPTION

A 4383540 Supporting bars kit for 1 SCF-V25


B 4383541 Supporting bars kit for 2 SCF-V25
C 4383542 Supporting bars kit for 3 SCF-V25
D 20008317 Fixing elements for FLAT ROOF
E 20008757 Coupling joint kit
F 20014661 Ending connection fittings kit for 2,5 m2 collector**

Composition table* of complete brackets kits for FLAT ROOF for SCF-V25 collector

20055493 20055495 20055496 20055497 20055498 20055499


REF. CODE DESCRIPTION kit for 1 kit for 2 kit for 3 kit for 4 kit for 5 kit for 6
collector collectors collectors collectors collectors collectors
A 4383540 Supporting bars kit for 1 SCF-V25 1 - - - - -
B 4383541 Supporting bars kit for 2 SCF-V25 - 1 - 2 1 -
C 4383542 Supporting bars kit for 3 SCF-V25 - - 1 - 1 2
D 20008317 Fixing elements for FLAT ROOF 2 2 3 5 6 7
E 20008757 Coupling joint kit - - - 1 1 1
Ending connection fittings kit for
F 20014661 1 1 1 1 1 1
2,5 m2 collector**
* This composition table must be read in vertical sense.
** The code 20014661 (ending connection fittings kit for 2,5 m2 collector), ref. F, contains the fittings for connection to copper pipes Ø 22 mm to be put at the inlet-outlet
of the collectors series and the fittings to be inserted at the outlet of the cylinder or of the flow-return hydraulic group.

A B C D E F

FOR COLLECTOR

2x

M12 M12
SOLAR THERMAL

FOR SOLAR CYLINDER


2x 2x 4x 6x
M8 x 20 M8 x 30
M8 M8

7x 2x 9x 5x

215
Collectors for forced circulation systems
SCF-25B - COLLECTOR with SEALED ALUMINIUM FRAME - 2,5m2

Ŷ Collector with sealed aluminium frame - 2,5 m2.


Ŷ Highly-selective aluminium absorber area.
Ŷ Complete with anti-irradiation film to be taken away at the activation of
the system.
Ŷ Insulation in rock wool (40 mm).
SOLAR Ŷ Collector stagnation temperature: 197 °C.
KEYMARK Ŷ Collector absorption: 95%.
certification Ŷ Possibility to connect up to 6 collectors in a series.
Ŷ This solar collector conforms to the EN 12975.
Ŷ Connection between collectors by means of 2 floating couplings.

Collector with sealed aluminium frame - 2,5 m2

DIMENSIONS COLLECTOR
CODE MODEL H×Ø TOTAL AREA
(mm) (m2)

20095375 SCF-25B 2.003 x 1.195 2,30

Packages

CODE MODEL

20095376 One package containing 2 pcs of code 20095375 SCF-25B

20095377 One package containing 5 pcs of code 20095375 SCF-25B

Accessories

CODE DESCRIPTION

20014661 Ending connection fittings kit for 2,5 m2 collector*


20001452 Fittings kit for flexible stainless steel pipes (connection with 2,5 m2 tray or Al frame collectors, and with solar cylinder)
20108734 Female ending fitting kit**
* The kit contains the fittings for connection to copper pipes Ø 22 mm to be put at the inlet-outlet of the collectors series and the fittings to be inserted at the outlet of the
cylinder or of the flow-return hydraulic group.
** The kit contains a fitting that allows to have, on both ends of the collector, a female connection.
= NEW (the green rectangle identifies a new code)

20001452 20014661 20108734


FOR COLLECTOR FOR COLLECTOR FOR COLLECTOR

FOR SOLAR CYLINDER FOR SOLAR CYLINDER

216
Collectors for forced circulation systems
SCF-25B - COLLECTOR with SEALED ALUMINIUM FRAME - 2,5m2
1195
1144 85

46,5
Ventilation holes
Collector
Collector
return
outlet

Collector
probe
socket
2003

Flow direction of the 3,2 mm glass


heat transfer liquid
Connection 1”

Collector ø 22 mm

Technical specifications

SEALED ALUMINIUM FRAME COLLECTOR


DESCRIPTION UOM
SCF-25B
Total area 2,30 m2
Exposed area 2,16 m2
Effective absorption area 2,15 m2
Connections (M) - (F) 1” -
Weight (empty) 40 kg
Liquid content 1,6 l
Recommended flow rate for 1 m2 collector 30 l/h
Glass thickness 3,2 mm
Absorption (Į) 95 %
Emissions (İ 4 %
IAM (50°) 0,96 -
Ș coll. (at 1000 W/m2) 61 %
Maximum permitted pressure 10 bar
Stagnation temperature 197 °C

Efficiency curve Head loss in solar collector (*)


0,80 30
0,75
25
0,70
Head loss (mbar)

0,65 20
0,60
SOLAR THERMAL

15
0,55
0,50 10
0,45
5
0,40
0,35 0
0 0,01 0,02 0,03 0,04 0,05 0,06 0,070,08 0 50 100 150 200 250 300 350
Tm[m2K/W] Flow rate (l/h)

(*) Test referred to a glycol-water mixture (33,3% - 67,7%), with 20 °C temperature of the heat-transfer fluid.

217
Collectors for forced circulation systems
SCF-25B - BRACKETS complete kits

Brackets for PITCHED ROOF - complete kits for SCF-25B collector

CODE DESCRIPTION

20099171 Brackets kit for PITCHED ROOF - 1 SCF-25B collector


20099172 Brackets kit for PITCHED ROOF - 2 SCF-25B collectors
20099173 Brackets kit for PITCHED ROOF - 3 SCF-25B collectors
20099174 Brackets kit for PITCHED ROOF - 4 SCF-25B collectors
20099175 Brackets kit for PITCHED ROOF - 5 SCF-25B collectors
20099176 Brackets kit for PITCHED ROOF - 6 SCF-25B collectors

Undertile brackets for PITCHED ROOF - complete kits for SCF-25B collector

CODE DESCRIPTION

20099177 Undertile brackets kit for PITCHED ROOF - 1 SCF-25B collector


20099178 Undertile brackets kit for PITCHED ROOF - 2 SCF-25B collectors
20099179 Undertile brackets kit for PITCHED ROOF - 3 SCF-25B collectors
20099180 Undertile brackets kit for PITCHED ROOF - 4 SCF-25B collectors
20099181 Undertile brackets kit for PITCHED ROOF - 5 SCF-25B collectors
20099186 Undertile brackets kit for PITCHED ROOF - 6 SCF-25B collectors

Brackets for FLAT ROOF - complete kits for SCF-25B collector

CODE DESCRIPTION

20099187 Brackets kit for FLAT ROOF - 1 SCF-25B collector


20099188 Brackets kit for FLAT ROOF - 2 SCF-25B collectors
20099189 Brackets kit for FLAT ROOF - 3 SCF-25B collectors
20099190 Brackets kit for FLAT ROOF - 4 SCF-25B collectors
20099191 Brackets kit for FLAT ROOF - 5 SCF-25B collectors
20099193 Brackets kit for FLAT ROOF - 6 SCF-25B collectors

The detailed composition of the complete brackets kits can be found in the composition tables of the following pages.

218
Collectors for forced circulation systems
SCF-25B - COMPOSITION TABLE of BRACKETS KITS for PITCHED ROOF

Brackets - primary codes for SCF-25B collector

REF. CODE DESCRIPTION REF. CODE DESCRIPTION

A 20087437 Supporting bars kit for 1 SCF-25B E 20087434 “B” fixing elements PITCHED ROOF
B 20087438 Supporting bars kit for 2 SCF-25B F 20093048 Coupling joint kit
C 20087439 Supporting bars kit for 3 SCF-25B H 20093046 Collectors blocking kit
D 20087433 “A” fixing elements PITCHED ROOF

Composition table* of complete brackets kits for PITCHED ROOF for SCF-25B collector

20099171 20099172 20099173 20099174 20099175 20099176


REF. CODE DESCRIPTION kit for 1 kit for 2 kit for 3 kit for 4 kit for 5 kit for 6
collector collectors collectors collectors collectors collectors
A 20087437 Supporting bars kit for 1 SCF-25B 1 - - - - -
B 20087438 Supporting bars kit for 2 SCF-25B - 1 - 2 1 -
C 20087439 Supporting bars kit for 3 SCF-25B - - 1 - 1 2
D 20087433 “A” fixing elements PITCHED ROOF 1 1 - 2 1 -
E 20087434 “B” fixing elements PITCHED ROOF - - 1 - 1 2
F 20093048 Coupling joint kit - - - 1 1 1
H 20093046 Collectors blocking kit 1 2 3 4 5 6
* This composition table must be read in vertical sense.

A B C D E F H

M12 M12 M12 M12

8x 12x 12x 18x


4x 6x
SOLAR THERMAL

2x

4x 4x 6x 6x 2x 2x 2x

219
Collectors for forced circulation systems
SCF-25B - COMPOSITION TABLE of UNDERTILE BRACKETS KITS for PITCHED ROOF
Undertile Brackets - primary codes for SCF-25B collector

REF. CODE DESCRIPTION REF. CODE DESCRIPTION

A 20087437 Supporting bars kit for 1 SCF-25B E 20093050 “B” fixing elements UNDERTILE
B 20087438 Supporting bars kit for 2 SCF-25B F 20093048 Coupling joint kit
C 20087439 Supporting bars kit for 3 SCF-25B H 20093046 Collectors blocking kit
D 20093049 “A” fixing elements UNDERTILE

Composition table* of complete undertile brackets kits for PITCHED ROOF for SCF-25B collector

20099177 20099178 20099179 20099180 20099181 20099186


REF. CODE DESCRIPTION kit for 1 kit for 2 kit for 3 kit for 4 kit for 5 kit for 6
collector collectors collectors collectors collectors collectors
A 20087437 Supporting bars kit for 1 SCF-25B 1 - - - - -
B 20087438 Supporting bars kit for 2 SCF-25B - 1 - 2 1 -
C 20087439 Supporting bars kit for 3 SCF-25B - - 1 - 1 2
D 20093049 “A” fixing elements UNDERTILE 1 1 - 2 1 -
E 20093050 “B” fixing elements UNDERTILE - - 1 - 1 2
F 20093048 Coupling joint kit - - - 1 1 1
H 20093046 Collectors blocking kit 1 2 3 4 5 6
* This composition table must be read in vertical sense.

A B C D E F H

M12 M12 M12 M12

8x 8x 12X 12x

2x 4x 6X
2x 2x 2x

4x 6x

220
Collectors for forced circulation systems
SCF-25B - COMPOSITION TABLE of BRACKETS KITS for FLAT ROOF
Brackets - primary codes for SCF-25B collector

REF. CODE DESCRIPTION REF. CODE DESCRIPTION

A 20087437 Supporting bars kit for 1 SCF-25B 20087436 45° fixing elements kit for FLAT ROOF (3 collectors)
E
B 20087438 Supporting bars kit for 2 SCF-25B 20093058 30° fixing elements kit for FLAT ROOF (3 collectors)
C 20087439 Supporting bars kit for 3 SCF-25B F 20093048 Coupling joint kit
20087435 45° fixing elements kit for FLAT ROOF (1-2 collectors) H 20093046 Collectors blocking kit
D
20093057 30° fixing elements kit for FLAT ROOF (1-2 collectors)

Composition table* of complete 45° brackets kits for FLAT ROOF for SCF-25B collector

20099187 20099188 20099189 20099190 20099191 20099193


REF. CODE DESCRIPTION kit for 1 kit for 2 kit for 3 kit for 4 kit for 5 kit for 6
collector collectors collectors collectors collectors collectors
A 20087437 Supporting bars kit for 1 SCF-25B 1 - - - - -
B 20087438 Supporting bars kit for 2 SCF-25B - 1 - 2 1 -
C 20087439 Supporting bars kit for 3 SCF-25B - - 1 - 1 2
45° fixing elements kit for FLAT ROOF
D 20087435 1 1 - 2 1 -
(1-2 collectors)
45° fixing elements kit for FLAT ROOF
E 20087436 - - 1 - 1 2
(3 collectors)
F 20093048 Coupling joint kit - - - 1 1 1
H 20093046 Collectors blocking kit 1 2 3 4 5 6
* This composition table must be read in vertical sense.

Composition table* of complete 30° brackets kits for FLAT ROOF for SCF-25B collector

kit for 1 kit for 2 kit for 3 kit for 4 kit for 5 kit for 6
REF. CODE DESCRIPTION
collector collectors collectors collectors collectors collectors
A 20087437 Supporting bars kit for 1 SCF-25B 1 - - - - -
B 20087438 Supporting bars kit for 2 SCF-25B - 1 - 2 1 -
C 20087439 Supporting bars kit for 3 SCF-25B - - 1 - 1 2
30° fixing elements kit for FLAT ROOF
D 20093057 1 1 - 2 1 -
(1-2 collectors)
30° fixing elements kit for FLAT ROOF
E 20093058 - - 1 - 1 2
(3 collectors)
F 20093048 Coupling joint kit - - - 1 1 1
H 20093046 Collectors blocking kit 1 2 3 4 5 6
* This composition table must be read in vertical sense.

A B C D E F H
SOLAR THERMAL

2x 3x
2x 3x

4x M8 x 20 6x M8 x 20
2x 4x 6x
4x 4x 6x 6x 6x 9x
4x M12 M12 M8 6x M12 M12 M8 2x 2x
2x
8x 12x 10x 12x 18x 15x

221
Collectors for forced circulation systems
SCF-25B - INSET FLASHING PLATES COMPLETE kits

Inset flashing plates in a single row - complete kits for SCF-25B collector

CODE DESCRIPTION

20112058 Inset flashing plates kit - 1 SCF-25B collector


20112059 Inset flashing plates kit - 2 SCF-25B collectors
20112060 Inset flashing plates kit - 3 SCF-25B collectors
20112062 Inset flashing plates kit - 4 SCF-25B collectors
20112063 Inset flashing plates kit - 5 SCF-25B collectors
20112064 Inset flashing plates kit - 6 SCF-25B collectors

= NEW (the green rectangle identifies a new code)

The detailed composition of the complete brackets kits can be found in the composition tables of the following pages.

222
Collectors for forced circulation systems
SCF-25B - COMPOSITION TABLE of INSET FLASHING PLATES kits

Inset flashing plates - primary codes for SCF-25B collector

REF. CODE DESCRIPTION REF. CODE DESCRIPTION

A 20087437 Supporting bars kit for 1 SCF-25B F 20093048 Coupling joint kit
B 20087438 Supporting bars kit for 2 SCF-25B H 20105558 Collectors blocking kit
C 20087439 Supporting bars kit for 3 SCF-25B I 20104833 Flashing plates for 1 SCF-25B collector
D 20105560 “A” fixing elements PITCHED ROOF L 20104834 Flashing plates for 2 SCF-25B collectors
E 20105562 “B” fixing elements PITCHED ROOF M 20104835 Additional flashing plates
= NEW (the green rectangle identifies a new code)

Composition table* of complete brackets kits for inset flashing plats for SCF-25B collector

20112058 20112059 20112060 20112062 20112063 20112064


REF. CODE DESCRIPTION kit for 1 kit for 2 kit for 3 kit for 4 kit for 5 kit for 6
collector collectors collectors collectors collectors collectors
A 20087437 Supporting bars kit for 1 SCF-25B 1 - - - - -
B 20087438 Supporting bars kit for 2 SCF-25B - 1 - 2 1 -
C 20087439 Supporting bars kit for 3 SCF-25B - - 1 - 1 2
D 20105560 “A” fixing elements PITCHED ROOF 1 1 - 2 1 -
E 20105562 “B” fixing elements PITCHED ROOF - - 1 - 1 2
F 20093048 Coupling joint kit - - - 1 1 1
H 20105558 Collectors blocking kit 1 2 3 4 5 6
I 20104833 Flashing plates for 1 SCF-25B collector 1 - - - - -
L 20104834 Flashing plates for 2 SCF-25B collectors - 1 1 1 1 1
M 20104835 Additional flashing plates - - 1 2 3 4

* This composition table must be read in vertical sense.

A B C D E F H
SOLAR THERMAL

I L M

223
Collectors for forced circulation systems
SCF-20B - COLLECTOR with SEALED ALUMINIUM FRAME - 2m2

Ŷ Collector with sealed aluminium frame - 2 m2.


Ŷ Highly-selective aluminium absorber area.
Ŷ Complete with anti-irradiation film to be taken away at the activation of
the system.
Ŷ Insulation in glass wool (30 mm).
SOLAR Ŷ Collector stagnation temperature: 192 °C.
KEYMARK Ŷ Collector absorption: 95%.
certification Ŷ Possibility to connect up to 6 collectors in a series.
Ŷ This solar collector conforms to the EN 12975.
Ŷ Connection between collectors by means of 4 floating couplings.

Collector with sealed aluminium frame - 2 m2

DIMENSIONS COLLECTOR
CODE MODEL H×Ø TOTAL AREA
(mm) (m2)

20095379 SCF-20B 1.818 x 1.097 1,91

Packages

CODE MODEL

20095380 One package containing 2 pcs of code 20095379 SCF-20B

20095381 One package containing 7 pcs of code 20095379 SCF-20B

Accessories

CODE DESCRIPTION

20014661 Ending connection fittings kit for 2 m2 collector*


20001452 Fittings kit for flexible stainless steel pipes (connection with 2 m2 tray or Al frame collectors, and with solar cylinder)
20108734 Female ending fitting kit**

* The kit contains the fittings for connection to copper pipes Ø 22 mm to be put at the inlet-outlet of the collectors series and the fittings to be inserted at the outlet of the
cylinder or of the flow-return hydraulic group.
** The kit contains a fitting that allows to have, on both ends of the collector, a female connection.

= NEW (the green rectangle identifies a new code)

20001452 20014661 20108734


FOR COLLECTOR FOR COLLECTOR FOR COLLECTOR

FOR SOLAR CYLINDER FOR SOLAR CYLINDER

224
Collectors for forced circulation systems
SCF-20B - COLLECTOR with SEALED ALUMINIUM FRAME - 2m2
1097
1048 70

49
Collector
outlet

Collector
probe
socket Ventilation holes
1818

Flow direction of the 3,2 mm glass


heat transfer liquid
Connection 1”

Collector
return
Collector ø 22 mm

Technical specifications

SEALED ALUMINIUM FRAME COLLECTOR


DESCRIPTION UOM
SCF-20B
Total area 1,91 m2
Exposed area 1,78 m2
Effective absorption area 1,77 m2
Connections (M) - (F) 2 X 1” M / 2 X 1” F -
Weight (empty) 30 kg
Liquid content 1,5 l
Recommended flow rate for 1 m2 collector 30 l/h
Glass thickness 3,2 mm
Absorption (Į) 95 %
Emissions (İ 4 %
IAM (50°) 0,87 -
Ș coll. (at 1000 W/m2) 58 %
Maximum permitted pressure 10 bar
Stagnation temperature 192 °C

Efficiency curve Head loss in solar collector (*)


0,80 12
0,75
10
0,70
Head loss (mbar)

0,65 8
SOLAR THERMAL

0,60
6
0,55
0,50 4
0,45
2
0,40
0,35 0
0 0,01 0,02 0,03 0,04 0,05 0,06 0,07 0,08
0 50 100 150 200 250 300 350 400
Tm[m2K/W] Flow rate (l/h)

(*) Test referred to a glycol-water mixture (33,3% - 67,7%), with 20 °C temperature of the heat-transfer fluid.

225
Collectors for forced circulation systems
SCF-20B - BRACKETS complete kits

Brackets for PITCHED ROOF - complete kits for SCF-20B collector

CODE DESCRIPTION

20099142 Brackets kit for PITCHED ROOF - 1 SCF-20B collector


20099143 Brackets kit for PITCHED ROOF - 2 SCF-20B collectors
20099144 Brackets kit for PITCHED ROOF - 3 SCF-20B collectors
20099145 Brackets kit for PITCHED ROOF - 4 SCF-20B collectors
20099146 Brackets kit for PITCHED ROOF - 5 SCF-20B collectors
20099147 Brackets kit for PITCHED ROOF - 6 SCF-20B collectors

Undertile brackets for PITCHED ROOF - complete kits for SCF-20B collector

CODE DESCRIPTION

20099149 Undertile brackets kit for PITCHED ROOF - 1 SCF-20B collector


20099150 Undertile brackets kit for PITCHED ROOF - 2 SCF-20B collectors
20099151 Undertile brackets kit for PITCHED ROOF - 3 SCF-20B collectors
20099152 Undertile brackets kit for PITCHED ROOF - 4 SCF-20B collectors
20099154 Undertile brackets kit for PITCHED ROOF - 5 SCF-20B collectors
20099156 Undertile brackets kit for PITCHED ROOF - 6 SCF-20B collectors

Brackets for FLAT ROOF - complete kits for SCF-20B collector

CODE DESCRIPTION

20099159 Brackets kit for FLAT ROOF - 1 SCF-20B collector


20099160 Brackets kit for FLAT ROOF - 2 SCF-20B collectors
20099163 Brackets kit for FLAT ROOF - 3 SCF-20B collectors
20099164 Brackets kit for FLAT ROOF - 4 SCF-20B collectors
20099165 Brackets kit for FLAT ROOF - 5 SCF-20B collectors
20099166 Brackets kit for FLAT ROOF - 6 SCF-20B collectors

The detailed composition of the complete brackets kits can be found in the composition tables of the following pages.

226
Collectors for forced circulation systems
SCF-20B - COMPOSITION TABLE of BRACKETS KITS for PITCHED ROOF

Brackets - primary codes for SCF-20B collector

REF. CODE DESCRIPTION REF. CODE DESCRIPTION

A 20087442 Supporting bars kit for 1 SCF-20B E 20087434 “B” fixing elements PITCHED ROOF
B 20087443 Supporting bars kit for 2 SCF-20B F 20093048 Coupling joint kit
C 20087444 Supporting bars kit for 3 SCF-20B G 20094627 Ending connection kit
D 20087433 “A” fixing elements PITCHED ROOF H 20093047 Collectors blocking kit

Composition table* of complete brackets kits for PITCHED ROOF for SCF-20B collector

20099142 20099143 20099144 20099145 20099146 20099147


REF. CODE DESCRIPTION kit for 1 kit for 2 kit for 3 kit for 4 kit for 5 kit for 6
collector collectors collectors collectors collectors collectors
A 20087442 Supporting bars kit for 1 SCF-20B 1 - - - - -
B 20087443 Supporting bars kit for 2 SCF-20B - 1 - 2 1 -
C 20087444 Supporting bars kit for 3 SCF-20B - - 1 - 1 2
D 20087433 “A” fixing elements PITCHED ROOF 1 1 - 2 1 -
E 20087434 “B” fixing elements PITCHED ROOF - - 1 - 1 2
F 20093048 Coupling joint kit - - - 1 1 1
G 20094627 Ending connection kit 1 1 1 1 1 1
H 20093047 Collectors blocking kit 1 2 3 4 5 6

* This composition table must be read in vertical sense.

A B C D E F G H

M12 M12 M12 M12

8x 12x 12x 18x


4x 6x
SOLAR THERMAL

2x
1x
4x 4x 6x 6x 2x 2x
2x

227
Collectors for forced circulation systems
SCF-20B - COMPOSITION TABLE of UNDERTILE BRACKETS KITS for PITCHED ROOF
Undertile Brackets - primary codes for SCF-20B collector

REF. CODE DESCRIPTION REF. CODE DESCRIPTION

A 20087442 Supporting bars kit for 1 SCF-20B E 20093050 “B” fixing elements UNDERTILE
B 20087443 Supporting bars kit for 2 SCF-20B F 20093048 Coupling joint kit
C 20087444 Supporting bars kit for 3 SCF-20B G 20094627 Ending connection kit
D 20093049 “A” fixing elements UNDERTILE H 20093047 Collectors blocking kit

Composition table* of complete undertile brackets kits for PITCHED ROOF for SCF-20B collector

20099149 20099150 20099151 20099152 20099154 20099156


REF. CODE DESCRIPTION kit for 1 kit for 2 kit for 3 kit for 4 kit for 5 kit for 6
collector collectors collectors collectors collectors collectors
A 20087442 Supporting bars kit for 1 SCF-20B 1 - - - - -
B 20087443 Supporting bars kit for 2 SCF-20B - 1 - 2 1 -
C 20087444 Supporting bars kit for 3 SCF-20B - - 1 - 1 2
D 20093049 “A” fixing elements UNDERTILE 1 1 - 2 1 -
E 20093050 “B” fixing elements UNDERTILE - - 1 - 1 2
F 20093048 Coupling joint kit - - - 1 1 1
G 20094627 Ending connection kit 1 1 1 1 1 1
H 20093047 Collectors blocking kit 1 2 3 4 5 6
* This composition table must be read in vertical sense.

A B C D E F G H

M12 M12 M12 M12

8x 8x 12X 12x

2x 4x 6X
1x
2x 2x 2x
4x 6x

228
Collectors for forced circulation systems
SCF-20B - COMPOSITION TABLE of BRACKETS KITS for FLAT ROOF
Brackets - primary codes for SCF-20B collector

REF. CODE DESCRIPTION REF. CODE DESCRIPTION

A 20087442 Supporting bars kit for 1 SCF-20B 20087436 45° fixing elements kit for FLAT ROOF (3 collectors)
E
B 20087443 Supporting bars kit for 2 SCF-20B 20093058 30° fixing elements kit for FLAT ROOF (3 collectors)
C 20087444 Supporting bars kit for 3 SCF-20B F 20093048 Coupling joint kit
20087435 45° fixing elements kit for FLAT ROOF (1-2 collectors) G 20094627 Ending connection kit
D
20093057 30° fixing elements kit for FLAT ROOF (1-2 collectors) H 20093047 Collectors blocking kit

Composition table* of complete 45° brackets kits for FLAT ROOF for SCF-20B collector

20099159 20099160 20099163 20099164 20099165 20099166


REF. CODE DESCRIPTION kit for 1 kit for 2 kit for 3 kit for 4 kit for 5 kit for 6
collector collectors collectors collectors collectors collectors
A 20087442 Supporting bars kit for 1 SCF-20B 1 - - - - -
B 20087443 Supporting bars kit for 2 SCF-20B - 1 - 2 1 -
C 20087444 Supporting bars kit for 3 SCF-20B - - 1 - 1 2
D 20087435 45° fixing elements kit for FLAT ROOF 1 1 - 2 1 -
(1-2 collectors)
E 20087436 45° fixing elements kit for FLAT ROOF - - 1 - 1 2
(3 collectors)
F 20093048 Coupling joint kit - - - 1 1 1
G 20094627 Ending connection kit 1 1 1 1 1 1
H 20093047 Collectors blocking kit 1 2 3 4 5 6
* This composition table must be read in vertical sense.

Composition table* of complete 30° brackets kits for FLAT ROOF for SCF-20B collector

REF. CODE DESCRIPTION kit for 1 kit for 2 kit for 3 kit for 4 kit for 5 kit for 6
collector collectors collectors collectors collectors collectors
A 20087442 Supporting bars kit for 1 SCF-20B 1 - - - - -
B 20087443 Supporting bars kit for 2 SCF-20B - 1 - 2 1 -
C 20087444 Supporting bars kit for 3 SCF-20B - - 1 - 1 2
D 20093057 30° fixing elements kit for FLAT ROOF 1 1 - 2 1 -
(1-2 collectors)
E 20093058 30° fixing elements kit for FLAT ROOF - - 1 - 1 2
(3 collectors)
F 20093048 Coupling joint kit - - - 1 1 1
G 20094627 Ending connection kit 1 1 1 1 1 1
H 20093047 Collectors blocking kit 1 2 3 4 5 6
* This composition table must be read in vertical sense.

A B C D E F G H
SOLAR THERMAL

2x 3x
2x 3x
2x M8 x 20
4x 6x M8 x 20
4x 6x
4x 4x 6x 6x 6x 9x 1x
4x M12 M12 M8 6x M12 M12 M8 2x 2x
8x 12x 10x
2x
12x 18x 15x

229
Collectors for forced circulation systems
SCO-25B - HORIZONTAL COLLECTOR with SEALED ALUMINIUM FRAME - 2,5m2

Ŷ Horizontal collector with sealed aluminium frame - 2,5 m2.


Ŷ Highly-selective aluminium absorber area.
Ŷ Complete with anti-irradiation film to be taken away at the
activation of the system.
SOLAR Ŷ Insulation in rock wool (40 mm).
KEYMARK Ŷ Collector absorption: 95%.
certification Ŷ Collector stagnation temperature: 200 °C.
Ŷ Possibility to connect up to 6 collectors in a series.
Ŷ Connection between collectors by means of 2 floating couplings.
Ŷ This solar collector conforms to the EN 12975.

Horizontal collector with sealed frame - 2,5 m2

DIMENSIONS COLLECTOR
CODE MODEL H×Ø TOTAL AREA
(mm) (m2)

20099915 SCO-25B 1.177 x 2.003 2,30

Packages

CODE MODEL

20099916 One package containing 5 pcs of code 20099915 SCO-25B

Accessories

CODE DESCRIPTION

20107056 Ending connection fittings kit for SCO-25B collector - 2,5 m2*
* The kit contains the fittings for connection to copper pipes Ø 22 mm to be put at the inlet-outlet of the collectors series.

230
Collectors for forced circulation systems
SCO-25B - HORIZONTAL COLLECTOR with SEALED ALUMINIUM FRAME - 2,5m2
Connection 1”
Collector ø 22 mm
Collector Collector
outlet return 3,2 mm glass
Collector
46,5 probe 46,5 85
socket

Flow direction
1172
1148

of the heat
transfer liquid

Ventilation holes

2003

Technical specifications

HORIZONTAL COLLECTOR WITH SEALED FRAME


DESCRIPTION UOM
SCO-25B
Total area 2,30 m2
Exposed area 2,16 m2
Effective absorption area 2,15 m2
Connections (M) - (M) 1” -
Weight (empty) 41 kg
Liquid content 1,6 l
Recommended flow rate for 1 m2 collector 30 l/h
Glass thickness 3,2 mm
Absorption (Į) 95 %
Emissions (İ 4 %
IAM (50°) 0,93 -
Ș coll. (at 1000 W/m2) 59,2 %
Maximum permitted pressure 10 bar
Stagnation temperature 200 °C

Efficiency curve Head loss in solar collector (*)


Head loss (mbar)

SOLAR THERMAL

Tm[m2K/W] Flow rate (l/h)


(*) Test referred to a glycol-water mixture (33,3% - 67,7%), with 20 °C temperature of the heat-transfer fluid.

231
Collectors for forced circulation systems
SCO-25B - BRACKETS complete kits

Brackets for PITCHED ROOF - complete kits for SCO-25B collector

CODE DESCRIPTION

20103498 Brackets kit for PITCHED ROOF - 1 SCO-25B collector


20103499 Brackets kit for PITCHED ROOF - 2 SCO-25B collectors
20103500 Brackets kit for PITCHED ROOF - 3 SCO-25B collectors
20103501 Brackets kit for PITCHED ROOF - 4 SCO-25B collectors
20103503 Brackets kit for PITCHED ROOF - 5 SCO-25B collectors
20103505 Brackets kit for PITCHED ROOF - 6 SCO-25B collectors

Undertile brackets for PITCHED ROOF - complete kits for SCO-25B collector

CODE DESCRIPTION

20103511 Undertile brackets kit for PITCHED ROOF - 1 SCO-25B collector


20103513 Undertile brackets kit for PITCHED ROOF - 2 SCO-25B collectors
20103514 Undertile brackets kit for PITCHED ROOF - 3 SCO-25B collectors
20103515 Undertile brackets kit for PITCHED ROOF - 4 SCO-25B collectors
20103516 Undertile brackets kit for PITCHED ROOF - 5 SCO-25B collectors
20103517 Undertile brackets kit for PITCHED ROOF - 6 SCO-25B collectors

Brackets for FLAT ROOF - complete kits for SCO-25B collector

CODE DESCRIPTION

20103520 Brackets kit for FLAT ROOF - 1 SCO-25B collector


20103521 Brackets kit for FLAT ROOF - 2 SCO-25B collectors
20103522 Brackets kit for FLAT ROOF - 3 SCO-25B collectors
20103524 Brackets kit for FLAT ROOF - 4 SCO-25B collectors
20103525 Brackets kit for FLAT ROOF - 5 SCO-25B collectors
20103529 Brackets kit for FLAT ROOF - 6 SCO-25B collectors

The detailed composition of the complete brackets kits can be found in the composition tables of the following pages.

232
Collectors for forced circulation systems
SCO-25B - COMPOSITION TABLE of BRACKETS KITS for PITCHED ROOF

Brackets - primary codes for SC0-25B collector

REF. CODE DESCRIPTION REF. CODE DESCRIPTION

A 20093053 Supporting bars kit for 1 SCO-25B F 20093048 Coupling joint kit
B 20093054 Supporting bars kit for 2 SCO-25B G 20093046 Collectors blocking kit
D 20087433 “A” fixing elements PITCHED ROOF H 20094626 Connection fittings
E 20087434 “B” fixing elements PITCHED ROOF

Composition table* of complete brackets kits for PITCHED ROOF for SCO-25B collector

20103498 20103499 20103500 20103501 20103503 20103505


REF. CODE DESCRIPTION kit for 1 kit for 2 kit for 3 kit for 4 kit for 5 kit for 6
collector collectors collectors collectors collectors collectors
A 20093053 Supporting bars kit for 1 SCO-25B 1 - 1 - 1 -
B 20093054 Supporting bars kit for 2 SCO-25B - 1 1 2 2 3
D 20087433 “A” fixing elements PITCHED ROOF 1 - 1 - 1 -
E 20087434 “B” fixing elements PITCHED ROOF - 1 1 2 2 3
F 20093048 Coupling joint kit - - 1 1 2 2
G 20093046 Collectors blocking kit 1 2 3 4 5 6
H 20094626 Connection fittings - 1 2 3 4 5
* This composition table must be read in vertical sense.

A B D E F G H

M12 M12 M12 M12 1x

8x 12x 12x 18x


4x 6x
2x
SOLAR THERMAL

4x 4x 6x 6x 2x 2x
2x

233
Collectors for forced circulation systems
SC0-25B - COMPOSITION TABLE of UNDERTILE BRACKETS KITS for PITCHED ROOF
Undertile Brackets - primary codes for SCO-25B collector

REF. CODE DESCRIPTION REF. CODE DESCRIPTION

A 20093053 Supporting bars kit for 1 SCO-25B F 20093048 Coupling joint kit

B 20093054 Supporting bars kit for 2 SCO-25B G 20093046 Collectors blocking kit

D 20093049 “A” fixing elements UNDERTILE H 20094626 Connection fittings

E 20093050 “B” fixing elements UNDERTILE

Composition table* of complete undertile brackets kits for PITCHED ROOF for SCF-2OB collector

20103511 20103513 20103514 20103515 20103516 20103517


REF. CODE DESCRIPTION kit for 1 kit for 2 kit for 3 kit for 4 kit for 5 kit for 6
collector collectors collectors collectors collectors collectors
A 20093053 Supporting bars kit for 1 SCO-25B 1 - 1 - 1 -
B 20093054 Supporting bars kit for 2 SCO-25B - 1 1 2 2 3
D 20093049 “A” fixing elements UNDERTILE 1 - 1 - 1 -
E 20093050 “B” fixing elements UNDERTILE - 1 1 2 2 3
F 20093048 Coupling joint kit - - 1 1 2 2
G 20093046 Collectors blocking kit 1 2 3 4 5 6
H 20094626 Connection fittings - 1 2 3 4 5
* This composition table must be read in vertical sense.

A B D E F G H

M12 M12 M12 M12


1x
8x 8x 12X 12x

2x 4x 6X
2x 2x
2x
4x 6x

234
Collectors for forced circulation systems
SCO-25B - COMPOSITION TABLE of BRACKETS KITS for FLAT ROOF
Brackets - primary codes for SCO-25B collector

REF. CODE DESCRIPTION REF. CODE DESCRIPTION

A 20093053 Supporting bars kit for 1 SCO-25B 20093056 “B” fixing elements FLAT ROOF - 45°
E
B 20093054 Supporting bars kit for 2 SCO-25B 20093678 “B” fixing elements FLAT ROOF - 30°
20093055 “A” fixing elements FLAT ROOF - 45° F 20093048 Coupling joint kit
D
20093677 “A” fixing elements FLAT ROOF - 30° G 20093046 Collectors blocking kit
H 20094626 Connection fittings

Composition table* of complete 45° brackets kits for FLAT ROOF for SCO-25B collector

20103520 20103521 20103522 20103524 20103525 20103529


REF. CODE DESCRIPTION kit for 1 kit for 2 kit for 3 kit for 4 kit for 5 kit for 6
collector collectors collectors collectors collectors collectors
A 20093053 Supporting bars kit for 1 SCO-25B 1 - 1 - 1 -
B 20093054 Supporting bars kit for 2 SCO-25B - 1 1 2 2 3
D 20093055 “A” fixing elements FLAT ROOF - 45° 1 - 1 - 1 -
E 20093056 “B” fixing elements FLAT ROOF - 45° - 1 1 2 2 3
F 20093048 Coupling joint kit - - 1 1 2 2
G 20093046 Collectors blocking kit 1 2 3 4 5 6
H 20094626 Connection fittings - 1 2 3 4 5
* This composition table must be read in vertical sense.

Composition table* of complete 30° brackets kits for FLAT ROOF for SCO-25B collector

kit for 1 kit for 2 kit for 3 kit for 4 kit for 5 kit for 6
REF. CODE DESCRIPTION collector collectors collectors collectors collectors collectors

A 20093053 Supporting bars kit for 1 SCO-25B 1 - 1 - 1 -


B 20093054 Supporting bars kit for 2 SCO-25B - 1 1 2 2 3
D 20093677 “A” fixing elements FLAT ROOF - 30° 1 - 1 - 1 -
E 20093678 “B” fixing elements FLAT ROOF - 30° - 1 1 2 2 3
F 20093048 Coupling joint kit - - 1 1 2 2
G 20093046 Collectors blocking kit 1 2 3 4 5 6
H 20094626 Connection fittings - 1 2 3 4 5
* This composition table must be read in vertical sense.

A B D E F G H
SOLAR THERMAL

2x 1x
3x
2x 3x

4x M8 x 20 M8 x 20
6x
4x 6x
2x
4x 4x 6x 6x 6x 9x
4x M12 M12 M8 6x M12 M12 M8 2x 2x
8x 12x 10x
2x
12x 18x 15x

235
Collectors for forced circulation systems
SCI-25N - WOOD FRAME INSET COLLECTOR - 2,5m2

Ŷ Wood frame inset collector - 2,5 m2.


Ŷ Highly-selective aluminium absorber area.
Ŷ Complete with anti-irradiation film to be taken away at the activation of
the system.
Ŷ Insulation in rock wool (40 mm).
SOLAR Ŷ Collector stagnation temperature: 202 °C.
KEYMARK Ŷ Collector absorption: 95%.
certification Ŷ Possibility to connect up to 6 collectors in a series.
Ŷ This solar collector conforms to the EN 12975.
Ŷ Suitable for ventilated roofs with an inclination between 20° and 65°.

Wood frame inset collector - 2,5 m2

DIMENSIONS COLLECTOR
CODE MODEL H×Ø TOTAL AREA
(mm) (m2)

20050330 SCI-25N 2.003 x 1.182 2,40

Packages

CODE MODEL

20050331 One package containing 2 pcs of code 20050330 SCI-25N

20050332 One package containing 7 pcs of code 20050330 SCI-25N

The manual air vent cannot be used with inset collectors; you have to use the solar filling pump (code 20001454), listed in the solar accessories section of this catalogue.

236
Collectors for forced circulation systems
SCI-25N - WOOD FRAME INSET COLLECTOR - 2,5m2
1182 Upper connection
96
50 1080 50 42,5
Collector Collector

36
outlet return

Collector
probe
socket
2033

Flow direction
of the heat
transfer liquid

Technical specifications

WOOD FRAME INSET COLLECTOR


DESCRIPTION UOM
SCI-25N
Total area 2,40 m2
Exposed area 2,2 m2
Effective absorption area 2,15 m2
Connections (F) - (F) 1” -
Weight (empty) 43 kg
Liquid content 1,68 l
Recommended flow rate for 1 m2 collector 30 l/h
Glass thickness 3,2 mm
Absorption (Į) ~95 %
Emissions (İ ~5 %
IAM (50°) 0,92 -
Ș coll. (at 1000 W/m2) 59 %
Maximum permitted pressure 10 bar
Stagnation temperature 202 °C

Efficiency curve Head loss in solar collector (*)


1 260
240
220
0,8 200
Head loss (mbar)

180
160
0,6
140
SOLAR THERMAL

120
0,4 100
80
60
0,2 40
20
0 0
0 0,02 0,04 0,06 0,08 0,1 0,12 0 100 200 300 400 500 600 700 800 900 1000 1200

Tm[m2K/W] Flow rate (l/h)

(*) Test referred to a glycol-water mixture (33,3% - 67,7%), with 20 °C temperature of the heat-transfer fluid.

237
Collectors for forced circulation systems
SCI-25N - INSET FLASHING PLATES complete kits

Inset flashing plates in a single row - complete kits for SCI-25N

CODE DESCRIPTION

20020406 Inset flashing plates kit - 1 SCI-25N collector


20020408 Inset flashing plates kit - 2 SCI-25N collectors
20020409 Inset flashing plates kit - 3 SCI-25N collectors
20020410 Inset flashing plates kit - 4 SCI-25N collectors
20020411 Inset flashing plates kit - 5 SCI-25N collectors
20020412 Inset flashing plates kit - 6 SCI-25N collectors

The ending fittings, code 20021321, to be put at the inlet-outlet of collectors and of hydraulic-group/cylinder, for connection to copper pipes, are included in the flashing
plates kits. For the composition of flashing plate kits refer to the tables below.

238
Collectors for forced circulation systems
SCI-25N - COMPOSITION TABLE of INSET FLASHING PLATES kits - SINGLE ROW

Inset flashing plates - primary codes for SCI-25N collector

REF. CODE DESCRIPTION

A 20019194 Inset flashing plates kit - 1 SCI-25N collector


A+B 20019195 Inset flashing plates kit - 2 SCI-25N collectors
B 20019196 Additional flashing plates kit SCI-25N collector
E 20019197 Hydraulic connections kit for SCI-25N collector
F 20021321 Fittings kit for copper pipes (connection with SCI-25N collector and with solar cylinder)

Composition table* of complete inset flashing plates kits for SCI-25N collector - single row

20020406 20020408 20020409 20020410 20020411 20020412


REF. CODE DESCRIPTION kit for 1 kit for 2 kit for 3 kit for 4 kit for 5 kit for 6
collector collectors collectors collectors collectors collectors
Inset flashing plates kit -
A 20019194 1 - - - - -
1 SCI-25N collector
Inset flashing plates kit -
A+B 20019195 - 1 1 1 1 1
2 SCI-25N collectors
Additional flashing plates kit
B 20019196 - - 1 2 3 4
SCI-25N collector
Hydraulic connections kit
E 20019197 - 1 2 3 4 5
for SCI-25N collector
Fittings kit for copper pipes
F 20021321 (connection with SCI-25N collector 1 1 1 1 1 1
and with solar cylinder) **
* This composition table must be read in vertical sense.
** The ending fittings kit, code 20021321 - ref. F, contains the fittings for connection to copper pipes Ø 22 mm to be put at the inlet-outlet of the collectors series and the
fittings to be inserted at the outlet of the cylinder or of the flow-return hydraulic group.

F
A
FOR COLLECTOR
A
B
FOR SOLAR CYLINDER A
E
B A
A

A B
SOLAR THERMAL

B
A

239
Collectors for forced circulation systems
SCI-25N - INSET FLASHING PLATES complete kits

Inset flashing plates in a double row - complete kits for SCI-25N

CODE DESCRIPTION

20020413 Inset flashing plates kit - 4 SCI-25N collectors in a double row


20020414 Inset flashing plates kit - 6 SCI-25N collectors in a double row
20020415 Inset flashing plates kit - 8 SCI-25N collectors in a double row
20020416 Inset flashing plates kit - 10 SCI-25N collectors in a double row
20020417 Inset flashing plates kit - 12 SCI-25N collectors in a double row

The ending fittings, code 20021321, to be put at the inlet-outlet of collectors and of hydraulic-group/cylinder, for connection to copper pipes, are included in the flashing
plates kits. For the composition of flashing plate kits refer to the tables below.

240
Collectors for forced circulation systems
SCI-25N - COMPOSITION TABLE of INSET FLASHING PLATES kits - DOUBLE ROW

Inset flashing plates - primary codes for SCI-25N collector

REF. CODE DESCRIPTION

A+B 20019195 Inset flashing plates kit - 2 SCI-25N collectors


B 20019196 Additional flashing plates kit SCI-25N collector
E 20019197 Hydraulic connections kit for SCI-25N collector
C+D 20019198 Second row inset flashing plates kit SCI-25N collector
D 20019199 Additional second row flashing plates kit SCI-25N collector
F 20021321 Fittings kit for copper pipes (connection with SCI-25N collector and with solar cylinder)

Composition table* of complete inset flashing plates kits for SCI-25N collector - double row

20020413 20020414 20020415 20020416 20020417


REF. CODE DESCRIPTION kit for 4 kit for 6 kit for 8 kit for 10 kit for 12
collectors collectors collectors collectors collectors
A+B 20019195 Inset flashing plates kit - 2 SCI-25N collectors 1 1 1 1 1
B 20019196 Additional flashing plates kit SCI-25N collector - 1 2 3 4
E 20019197 Hydraulic connections kit for SCI-25N collector 2 4 6 8 10
Second row inset flashing plates kit
C+D 20019198 1 1 1 1 1
SCI-25N collector
Additional second row flashing plates kit
D 20019199 - 1 2 3 4
SCI-25N collector
Fittings kit for copper pipes (connection with SCI-
F 20021321 1 1 1 1 1
25N collector and with solar cylinder)
* This composition table must be read in vertical sense.
** The ending fittings kit, code 20021321 - ref. F, contains the fittings for connection to copper pipes Ø 22 mm to be put at the inlet-outlet of the collectors series and the
fittings to be inserted at the outlet of the cylinder or of the flow-return hydraulic group.

F A

C
FOR COLLECTOR B
C
E
B A
FOR SOLAR CYLINDER C
C
D
C
A
D
A
E
SOLAR THERMAL

C
D
A
C
A B
C

B
A

241
Collectors for forced circulation systems
SCV-25 - EVACUATED TUBE COLLECTOR - 2,5m2

Ŷ Evacuated tube collector - 2,5 m2.


Ŷ High efficiency thanks to the high thermal insulation provided by
vacuum tubes.
Ŷ Highly-selective finish of the copper absorber.
SOLAR Ŷ Collector absorption: >94%.
KEYMARK Ŷ Collector stagnation temperature: 268 °C.
certification Ŷ Possibility to connect up to 6 collectors in a series.
Ŷ This solar collector conforms to the EN 12975.

Evacuated tube collector - 2,5 m2

DIMENSIONS COLLECTOR
CODE MODEL H×Ø TOTAL AREA
(mm) (m2)

20026324 SCV-25 1.730 x 1.600 2,77

Note: SCV-25 evacuated tube collector must be used with inorganic glycol.

Accessories

CODE DESCRIPTION

20094030 Evacuated premix glycol 20 kg

242
Collectors for forced circulation systems
SCV-25 - EVACUATED TUBE COLLECTOR - 2,5m2
1600 145
1552 68

65
Collector Collector
return outlet

Collector
probe
socket
1730

1700
110x14

Technical specifications
EVACUATED TUBE COLLECTOR
DESCRIPTION UOM
SCV-25
Total area 2,77 m2
Exposed area 2,40 m2
Effective absorption area 2,69 m2
Connections fittings for Ø 18 pipes to be tightened -
Weight (empty) 52 kg
Liquid content 2,05 l
Recommended flow rate for 1 m2 collector 30 l/h
Absorption (Į) ≥94 %
Emissions (İ <7 %
IAM T (50°) 1,07 -
IAM L (50°) 0,954 -
Ș coll. (at 1000 W/m2) 64 %
Maximum permitted pressure 10 bar
Stagnation temperature 268 °C

Efficiency curve referred to the exposed area Head loss in solar collector
1 900
800
0,8 700
Head loss (mbar)

600
SOLAR THERMAL

0,6
500
400
0,4
300

0,2 200
100
0 0
0 0,02 0,04 0,06 0,08 0,1 0 500 1000 1500 2000 2500 3000 3500
Tm[m2K/W] Flow rate (l/h)

243
Collectors for forced circulation systems
SCV-25 - BRACKETS complete kits

Brackets for PITCHED ROOF - complete kits for SCV-25 collector with fittings for copper pipes Ø 18

CODE DESCRIPTION

20027341 Brackets kit for PITCHED ROOF - 1 SCV-25 collector


20027342 Brackets kit for PITCHED ROOF - 2 SCV-25 collectors
20027343 Brackets kit for PITCHED ROOF - 3 SCV-25 collectors
20027344 Brackets kit for PITCHED ROOF - 4 SCV-25 collectors
20027345 Brackets kit for PITCHED ROOF - 5 SCV-25 collectors
20027346 Brackets kit for PITCHED ROOF - 6 SCV-25 collectors

The detailed composition of the complete brackets kits can be found in the composition tables of the following pages.

244
Collectors for forced circulation systems
SCV-25 - BRACKETS complete kits

Brackets for FLAT ROOF - complete kits for SCV-25 collector with fittings for copper pipes Ø 18

CODE DESCRIPTION

20027335 Brackets kit for FLAT ROOF - 1 SCV-25 collector


20027336 Brackets kit for FLAT ROOF - 2 SCV-25 collectors
20027337 Brackets kit for FLAT ROOF - 3 SCV-25 collectors
20027338 Brackets kit for FLAT ROOF - 4 SCV-25 collectors
20027339 Brackets kit for FLAT ROOF - 5 SCV-25 collectors
20027340 Brackets kit for FLAT ROOF - 6 SCV-25 collectors

The detailed composition of the complete brackets kits can be found in the composition tables of the following pages.

SOLAR THERMAL

245
Collectors for forced circulation systems
SCV-25 - COMPOSITION TABLE of BRACKETS KITS for PITCHED ROOF

Brackets - primary codes for SCV-25 collector

REF. CODE DESCRIPTION

A 20026381 Supporting bars kit for 1 SCV-25


B 20026383 Supporting bars kit for 2 SCV-25
D 20008292 Fixing elements kit for PITCHED ROOF
- 20013464 Undertile fixing elements kit for PITCHED ROOF
E 20008757 Coupling joint kit
F 20027281 Straight fittings kits Ø 18 to be tightened

Composition table* of complete brackets kits for PITCHED ROOF for SCV-25 collector

20027341 20027342 20027343 20027344 20027345 20027346


REF. CODE DESCRIPTION kit for 1 kit for 2 kit for 3 kit for 4 kit for 5 kit for 6
collector collectors collectors collectors collectors collectors
A 20026381 Supporting bars kit for 1 SCV-25 1 - 1 - 1 -
B 20026383 Supporting bars kit for 2 SCV-25 - 1 1 2 2 3
D 20008292 Fixing elements kit for PITCHED ROOF 2 3 5 6 8 9
E 20008757 Coupling joint kit - - 1 1 2 2
F 20027281 Straight fittings kits Ø 18 to be tightened 1 2 2 3 3 4

* This composition table must be read in vertical sense.

A B D E F

M12 M12 M8

4x 6x 4x
M8 x 20

2x 2x 4x

246
Collectors for forced circulation systems
SCV-25 - COMPOSITION TABLE of BRACKETS KITS for FLAT ROOF

Brackets - primary codes for SCV-25 collector

REF. CODE DESCRIPTION

A 20026381 Supporting bars kit for 1 SCV-25


B 20026383 Supporting bars kit for 2 SCV-25
D 20026384 Fixing elements kit for FLAT ROOF for SCV-25
E 20008757 Coupling joint kit
F 20027281 Straight fittings kits Ø 18 to be tightened

Composition table* of complete brackets kits for FLAT ROOF for SCV-25 collector

20027335 20027336 20027337 20027338 20027339 20027340


RIF. CODE DESCRIPTION kit for 1 kit for 2 kit for 3 kit for 4 kit for 5 kit for 6
collector collectors collectors collectors collectors collectors
A 20026381 Supporting bars kit for 1 SCV-25 1 - 1 - 1 -
B 20026383 Supporting bars kit for 2 SCV-25 - 1 1 2 2 3
Fixing elements kit for FLAT ROOF for
D 20026384 2 3 5 6 8 9
SCV-25
E 20008757 Coupling joint kit - - 1 1 2 2
F 20027281 Straight fittings kits Ø 18 to be tightened 1 2 2 3 3 4
* This composition table must be read in vertical sense.

A B D E F

2x

M12 M12

2x 2x 4x 6x
SOLAR THERMAL

M8 x 20 M8 x 30
M8 M8

7x 2x 9x 5x

247
Solar thermal
PRODUCT MATRIX OF BERETTA SOLAR CYLINDERS AND BUFFER TANKS

DESCRIPTION TYPE CAPACITY RANGE INTERIOR


IN LITRES TREATMENT

IDRA FI - LE
150
MS
enamelled
cylinder
(double layer)
IDRA FI - LE DS 200-300-430-550

IDRA MS 150-200-300-430-550
enamelled
cylinder
DHW PRODUCTION

(double layer)
IDRA DS 200-300-430-550-750-1000

IDRA N DS cylinder 1500-2000-2600 enamelled

IDRA PLUS DS cylinder 1000-1500-2000-3000 enamelled


and HEATING SUPPLEMENT

not enamelled
multi-energy
HYBRID STOR 430-550-750-1000 (not suitable for
DHW PRODUCTION

tank
DHW storage)

enamelled (double layer)


combined tank for DHW production,
STOR C 800-1000
storage tank inside a steel solar tank
(tank-in-tank technology)
SUPPLEMENT

STOR M 300-500-1000-1500
HEATING

not enamelled
buffer tank (not suitable for
DHW storage)
STOR 2000-3000-5000
and COOLING
HEATING

not enamelled
cold/hot water
STOR H (*) 200-300-400-500 (not suitable for
buffer tank
DHW storage)

N.B. For the Energy Class of each product refer to the dedicated product page.
(*) This product is treated in the “Heat Pumps” section.

248
HEAT-EXCHANGER FLANGES SPECIFIC SACRIFICIAL SUITABILITY FOR
COIL FEATURES MAGNESIUM ANODE ELECTRICAL RESISTANCE

one coil pre-installed hydraulic group


(flow and return) featuring
one suitable
one flange a Low Energy modulating
(as standard) (Ø 1 ½” F connection)
cinrculator and a SUN B solar
two coils controller

one coil one up to 550 lt. models;


high heat exchange capacity two on 750 lt. and suitable
one flange
of the coils 1000 lt. models (Ø 1 ½” F connection)
two coils (as standard)

two suitable
two coils one flange high storage capacity
(as standard) (Ø 1 ½” F connection)

three flanges
_ (suitable for up to three two suitable
high storage capacity
heat-exchanger coils - (as standard) (Ø 1 ½” F connection)
available as accessories)

3 coils suitable for combination with


(including a DHW _ boilers, solar thermal, heat _ suitable
coil in AISI 316L pumps, biomass boilers and (Ø 1 ½” F connection)
stainless-steel) other heat generators

seven fittings at different


heights for the best stratification one suitable
one coil (solar) one flange
for the use of different types of (as standard) (Ø 1 ½” F connection)
heat generators

one coil (solar)


_
eight fittings at different heights
for the best stratification for the _ _
one flange use of different types of heat
_ (suitable for one generators
heat-exchanger coil
as accessory)

specifically designed for


combination with heat pumps;
SOLAR THERMAL

_ _ _ suitable
suitable also in systems with
(Ø 1 ½” F connection)
solar thermal and biomass
boilers

249
Solar cylinders
IDRA MS/DS FI LE - with LOW ENERGY HYDRAULIC GROUP and CONTROL-BOX

Ŷ Solar cylinders with pre-installed hydraulic group (flow and return)


- featuring a Low Energy modulating circulator - and SUN B
solar controller.
Ŷ Vertical steel enamelled (double layer) solar cylinder.
Ŷ Maximum working temperature 99 °C.
Ŷ Coils and cylinders maximum working pressure: 10 bar.
Ŷ Double coils heat-exchanger (IDRA DS FI - LE models).
Ŷ Single coil heat-exchanger (IDRA MS FI - LE models).
Ŷ High heat exchange capacity of the coils.
Ŷ Suitable for electrical resistance.
Ŷ Sacrificial magnesium anode included with the standard
equipment.
Ŷ CFC-free polyurethane direct foaming insulation method.

With Low Energy hydraulic group and solar control-box

DIMENSIONS CYLINDER ENERGY CLASS


HEAT LOSS
CODE MODEL with insulation CAPACITY
(W)
H × Ø (mm) (litres)
SINGLE COIL CYLINDERS

20096928 IDRA MS 150 FI - LE 1.055 x 605 150 single coil 96

DOUBLE COILS CYLINDERS

20096929 IDRA DS 200 FI - LE 1.330 x 605 205 double coil 74

20096930 IDRA DS 300 FI - LE 1.840 x 605 296 double coil 69

20096931 IDRA DS 430 FI - LE 1.630 x 755 441 double coil 60

20096932 IDRA DS 550 FI - LE 1.980 x 755 550 double coil 68 -


For EXPANSION VESSELS see the dedicated section “ACCESSORIES FOR SOLAR THERMAL”.

Accessories

CODE DESCRIPTION

Specific accessories
4383270 Single-phase electrical resistance 1,5 kW, 1” 1/2
4383271 Single-phase electrical resistance 2,2 kW, 1” 1/2
4383272 Single-phase electrical resistance 3 kW, 1” 1/2
20020707 Three-phase electrical resistance 3,8 kW, 1” 1/2
20001492 Thermostatic mixing valve 1” with 3/4” adapter
1220599 Socket probe for boilers
20055206 Electrical anode kit 1/2” (*)
(*) To connect the electrical anode kit, provide a reduction (not supplied as standard) from 1” ¼ to ½”.
N.B. The sacrificial magnesium anode should be periodically monitored and replaced.
N.B. Beretta strongly recommend to connect the tanks to the electrical earth of the plant.

250
Solar cylinders
IDRA MS/DS FI LE - with LOW ENERGY HYDRAULIC GROUP and CONTROL-BOX

A
B

Technical specifications

IDRA MS IDRA DS IDRA DS IDRA DS IDRA DS


DESCRIPTION UOM
150 FI - LE 200 FI - LE 300 FI - LE 430 FI - LE 550 FI - LE
Cylinder capacity 150 205 296 441 550 l
Cylinder diameter with insulation without hydraulic group (A) 605 755 mm
Cylinder diameter with hydraulic group (B) 825 805 955 mm
Height with insulation (H) 1055 1330 1840 1630 1980 mm
Insulation thickness 50 mm
Probe sockets diameter/length 16/175 mm
Lower coil water content 4,8 5,7 9,3 11,0 12,8 l
Upper coil water content - 4,1 5,5 7,1 8,0 l
Lower coil exchange surface 0,78 0,94 1,53 1,80 2,10 m2
Upper coil exchange surface - 0,68 0,91 1,17 1,31 m2
Lower coil absorbed power (*) 28 29,5 46,6 52,0 62,0 kW
Upper coil absorbed power (*) - 20,7 30,6 36,5 43,0 kW
Electrical power modulating Low Energy circulator (max/min) 60/2 60/2 60/2 60/2 60/2 W
Net weight with insulation 72 105 130 162 175 kg
* With ΔT = 35 °C and primary temperature = 80 °C (3.000 l/h)

Head losses Head losses


UPPER COIL IDRA DS FI - LE LOWER COIL IDRA MS/DS FI - LE

600 600

550 550
Mod. 550
500 500
Mod. 430
Mod. 550
SOLAR THERMAL
HEAD LOSSES (mbar)

450 450 Mod. 300


HEAD LOSSES (mbar)

400 Mod. 430 400


Mod. 300 Mod. 200
350 350

300 Mod. 200 300 Mod. 150

250 250

200 200

150 150

100 100

50 50

0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000

FLOW RATE (l/h) FLOW RATE (l/h)

251
Solar cylinders
IDRA MS - with INCREASED COIL SURFACE

Ŷ Enamelled (double layer) steel solar cylinder (150 to 550-litres


models).
Ŷ Single coil heat-exchanger.
Ŷ Maximum working temperature 99 °C.
Ŷ Coils and cylinders maximum working pressure: 10 bar.
Ŷ High heat exchange capacity of the coils.
Ŷ Suitable for electrical resistance.
Ŷ Sacrificial magnesium anode included with the standard equipment.

Single coil solar cylinder with increased coil surface

DIMENSIONS CYLINDER ENERGY CLASS


HEAT LOSS
CODE MODEL with insulation CAPACITY
(W)
H × Ø (mm) (litres)

20072887 IDRA MS 150 1.055 x 605 150 single coil 96

20015324 IDRA MS 200 1.330 × 605 208 single coil 116 E

20015328 IDRA MS 300 1.840 × 605 305 single coil 93

20015333 IDRA MS 430 1.630 × 755 442 single coil 91

20015340 IDRA MS 550 1.980 × 755 556 single coil 114

Accessories

CODE DESCRIPTION

Specific accessories
20009244 Solar control box SUN B with probes
20009246 Solar control box SUN C with probes
1220599 Socket probe for boilers
20001492 Thermostatic mixing valve 1” with 3/4” adapter

N.B. The sacrificial magnesium anode should be periodically monitored and replaced.
N.B. Beretta strongly recommend to connect the tanks to the electrical earth of the plant.

252
Solar cylinders
IDRA MS - with INCREASED COIL SURFACE
AD AD
UAC - DHW outlet
M - Flow
UAC Solar
R - Return
RL - DHW recirculation
EAF - Domestic cold water inlet
SB - Cylinder drain
RE - Electrical probe socket (not provided)
AD - Magnesium anode
M R M R
RE

RL

EAF

(SB)

Technical specifications

IDRA IDRA IDRA IDRA IDRA


DESCRIPTION UOM
MS 150 MS 200 MS 300 MS 430 MS 550
Cylinder capacity 150 208 305 442 556 l
Cylinder diameter with insulation 605 755 mm
Height with insulation 1055 1330 1840 1630 1980 mm
Insulation thickness 50 mm
Probe sockets diameter/length 16/175 mm
Coil water content 4,8 5,7 9,3 11,0 12,8 l
Coil exchange surface 0,78 0,94 1,53 1,80 2,10 m2
Coil absorbed power (**) 28 29,5 46,6 52,0 62,0 kW
DHW production - coil (**) 585 725 1145 1278 1523 l/h
Cylinder maximum working pressure 10 bar
Net weight with insulation 62 70 100 135 150 kg
** With ΔT = 35 °C and primary temperature = 80 °C (3.000 l/h)

900
Mod. 550
800
Mod. 430
700 Mod. 300
HEAD LOSSES (mbar)

600 Mod. 200


SOLAR THERMAL

500

400
Mod. 150*
300

200

100

0
0 1000 2000 3000 4000 5000 6000
FLOW RATE (l/h)

253
Solar cylinders
IDRA DS - with INCREASED COIL SURFACE

Ŷ Enamelled (double layer) steel solar cylinder.


Ŷ Double coil heat-exchanger.
Ŷ Maximum working temperature 99 °C.
Ŷ Coils and cylinders maximum working pressure: 10 bar.
Ŷ High heat exchange capacity of the coils.
Ŷ Suitable for electrical resistance.
Ŷ Sacrificial magnesium anode included with the standard equipment
(double anode for 750 and 1000 litres models).
Ŷ CFC-free polyurethane direct foaming insulation method
(200 to 550-litres models).

Double coil solar cylinder with increased coil surface

DIMENSIONS CYLINDER ENERGY CLASS


HEAT LOSS
CODE MODEL with insulation CAPACITY
(W)
H × Ø (mm) (litres)

20001224 IDRA DS 200 1.330 × 605 205 double coil 74

20001225 IDRA DS 300 1.840 × 605 296 double coil 69

20001226 IDRA DS 430 1.630 × 755 441 double coil 60

20001227 IDRA DS 550 1.980 × 755 550 double coil 68 -

20009144 IDRA DS 750 1.870 x 1.000 716 double coil 156 -

20009145 IDRA DS 1000 2.195 x 1.000 875 double coil 175 -

Accessories

CODE DESCRIPTION CODE DESCRIPTION

Specific accessories 20009244 Solar control box SUN B with probes


4383270 Single-phase electrical resistance 1,5 kW, 1” 1/2 20009246 Solar control box SUN C with probes
4383271 Single-phase electrical resistance 2,2 kW, 1” 1/2 1220599 Socket probe for boilers
4383272 Single-phase electrical resistance 3 kW, 1” 1/2 Connection bends kit for hydraulic group
20027382
(residual head 6,5m) and solar cylinder
20079908 Single-phase electrical resistance 6,0 kW, 1” 1/2
Connection bends kit for hydraulic group
Three-phase electrical resistance 3,8 kW, 1” 1/2 20009438
20020707 (residual head 11m) and solar cylinder
(for IDRA DS 550-750-1000 models)
20001492 Thermostatic mixing valve 1” with 3/4” adapter

N.B. The sacrificial magnesium anode should be periodically monitored and replaced.
N.B. Beretta strongly recommend to connect the tanks to the electrical earth of the plant.

254
Solar cylinders
IDRA DS - with INCREASED COIL SURFACE
AD AD

UAC - DHW outlet


UAC MC - Flow
Boiler
RC - Return
MC
MC M - Flow
Solar
R - Return
RL - DHW recirculation
RC
EAF - Domestic cold water inlet
RE M R RC M R SB - Cylinder drain
RE - Electrical probe socket (not provided)
RL
AD - Magnesium anode

EAF

(SB)

Technical specifications

IDRA IDRA IDRA IDRA IDRA IDRA


DESCRIPTION UOM
DS 200 DS 300 S 430 DS 550 DS 750 DS 1000

Cylinder capacity 205 296 441 550 716 875 l


Cylinder diameter with insulation 605 755 1000 mm
Height with insulation 1330 1840 1630 1980 1870 2195 mm
Insulation thickness 50 100 mm
Probes sockets diameter/length 16/175 17/210 mm
Lower coil water content 5,7 9,3 11,0 12,8 16,0 19,0 l
Upper coil water content 4,1 5,5 7,1 8,0 10,2 10,2 l
Lower coil exchange surface 0,94 1,53 1,80 2,10 2,80 3,16 m2
Upper coil exchange surface 0,68 0,91 1,17 1,31 1,70 1,70 m2
Lower coil absorbed power (*) 29,5 46,6 52,0 62,0 76,0 92,0 kW
Upper coil absorbed power (*) 20,7 30,6 36,5 43,0 58,0 58,0 kW
DHW production - lower coil (*) 725 1145 1278 1523 1856 2219 l/h
DHW production - upper coil (*) 508 753 897 1056 1425 1425 l/h
Cylinder maximum working pressure 10 7 bar
Coil maximum working pressure 10 bar
Net weight 78 109 139 169 214 244 kg
* With ΔT = 35 °C and primary temperature = 80 °C (3.000 l/h)

Head losses Head losses


UPPER COIL IDRA DS LOWER COIL IDRA DS
00 1100
Mod. 1000 Mod. 750
Mod. 1000
00 1000
Mod. 750
00 900
SOLAR THERMAL
HEAD LOSSES (mbar)

Mod. 550
00 800
Mod. 430
00 700 Mod. 300

00 600 Mod. 200

00 500
Mod. 550
00 Mod. 430 400
Mod. 300
Mod. 200
00 300

00 200

00 100

0 0
0 1000 2000 3000 4000 5000 6000 0 1000 2000 3000 4000 5000
FLOW RATE (l/h) FLOW RATE (l/h)

255
Solar cylinder
IDRA N DS - with HIGH STORAGE CAPACITY

Ŷ Vertical steel enamelled solar cylinder.


Ŷ Maximum working temperature 99 °C.
Ŷ Double coil heat-exchanger.
Ŷ High heat exchange capacity of the coils.
Ŷ Suitable for electrical resistance.
Ŷ Double magnesium anode included with the standard equipment.

Double coil cylinder with high storage capacity

DIMENSIONS CYLINDER
HEAT LOSS
CODE MODEL with insulation CAPACITY
(W)
H × Ø (mm) (litres)

20052790 IDRA N DS 1500 2.185 × 1.200 1390 double coil 250

20052791 IDRA N DS 2000 2.470 × 1.300 1950 double coil 305

20086803 IDRA N DS 2600 2.455 × 1.450 2572 double coil 330

For EXPANSION VESSELS see the dedicated section “ACCESSORIES FOR SOLAR THERMAL”.

Accessories

CODE DESCRIPTION

Specific accessories
4383270 Single-phase electrical resistance 1,5 kW, 1” 1/2
4383271 Single-phase electrical resistance 2,2 kW, 1” 1/2
4383272 Single-phase electrical resistance 3 kW, 1” 1/2
20079908 Single-phase electrical resistance 6,0 kW, 1” 1/2
20020707 Three-phase electrical resistance 3,8 kW, 1” 1/2
20001492 Thermostatic mixing valve 1” with 3/4” adapter
20009244 Solar control box SUN B with probes
20009246 Solar control box SUN C with probes
20055206 Electrical anode kit 1/2” (*)

(*) To connect the electrical anode kit, provide a reduction (not supplied as standard) from 1” ¼ to ½”.
N.B. The sacrificial magnesium anode should be periodically monitored and replaced.
N.B. Beretta strongly recommend to connect the tanks to the electrical earth of the plant.

256
Solar cylinder
IDRA N DS - with HIGH STORAGE CAPACITY
UAC - DHW outlet
MC - Flow
Boiler
RC - Return
UAC
M - Flow
Solar
MC R - Return
RL - DHW recirculation
EAF - Domestic cold water inlet
RC SB - Cylinder drain
RL
M

EAF
SB

Technical specifications

DESCRIPTION IDRA N DS 1500 IDRA N DS 2000 IDRA N DS 2600 UOM

Cylinder capacity 1390 1950 2572 l


Cylinder diameter with insulation 1200 1300 1450 mm
Cylinder diameter without insulation 1000 1100 1250 mm
Height with insulation 2185 2470 2455 mm
Insulation thickness 100 mm
Probes sockets diameter 8 8 8 mm
Lower coil water content 19,4 28,1 28,4 l
Upper coil water content 10,4 16,9 20,3 l
Lower coil exchange surface 3,4 4,6 4,6 m2
Upper coil exchange surface 1,8 2,8 3,3 m2
Lower coil absorbed power (*) 88 120 110 kW
Upper coil absorbed power (*) 47 73 79 kW
Cylinder maximum working pressure 8 bar
Coil maximum working pressure 6 bar
Net weight with insulation 330 544 600 kg
* With ΔT = 35 °C and primary temperature = 80 °C

Head losses Head losses


UPPER COIL LOWER COIL
600 1000
2000 2000
900
1500
500
1500 800
2600
HEAD LOSSES (mbar)

HEAD LOSSES (mbar)

2600
700
400
600
SOLAR THERMAL

300 500

400
200
300

200
100
100

0 0
0 1000 2000 3000 4000 5000 6000 0 1000 2000 3000 4000 5000 6000

FLOW RATE (l/h) FLOW RATE (l/h)

257
Solar cylinders
IDRA PLUS DS - FLANGED with HIGH STORAGE CAPACITY

Ŷ Enamelled steel solar cylinder with flanges.


Ŷ Maximum working temperature 99 °C.
Ŷ Possibility to insert up to 3 coils.
Ŷ Coils kit with high heat exchanger capacity (accessories).
Ŷ Coils maximum working pressure: 6 bar.
Ŷ Suitable for electrical resistance.
Ŷ Double magnesium anode included with the standard equipment.

Flanged cylinders with high storage capacity

DIMENSIONS CYLINDER
HEAT LOSS
CODE MODEL with insulation CAPACITY
(W)
H × Ø (mm) (litres)

20052793 IDRA PLUS DS 1000 2.095 × 990 880 three flanges 193

20052794 IDRA PLUS DS 1500 2.155 × 1.200 1430 three flanges 250

20052795 IDRA PLUS DS 2000 2.470 × 1.300 1990 three flanges 305

20052796 IDRA PLUS DS 3000 2.730 × 1.450 2959 three flanges 344

Cylinders are supplied with flanges but without coils. To select the right coils consult the section below “Specific accessories”.
For EXPANSION VESSELS see the dedicated section “ACCESSORIES FOR SOLAR THERMAL”.

Accessories

CODE DESCRIPTION CODE DESCRIPTION

Specific accessories 20079908 Single-phase electrical resistance 6,0 kW, 1” 1/2


Tin coated copper coil kit 2,63 m2 20020707 Three-phase electrical resistance 3,8 kW, 1” 1/2
20055205
- 53kW - 1,74L - 10bar
20055206 (***) Electrical anode kit 1/2”
Tin coated copper coil kit 4,54 m2
4383089
- 91kW - 3,56L - 10bar 20009244 Solar control box SUN B with probes
Tin coated copper coil kit 6,34 m2 20009246 Solar control box SUN C with probes
4383087(**)
- 127kW - 5,10L - 10bar
20001492 Thermostatic mixing valve 1” with 3/4” adapter
4383272 Single-phase electrical resistance 3 kW, 1” 1/2
(**) Not suitable for IDRA PLUS DS 1000.
(***) To connect the electrical anode kit, provide a reduction (not supplied as standard) from 1” ¼ to ½”.
N.B. The sacrificial magnesium anode should be periodically monitored and replaced.
N.B. Beretta strongly recommend to connect the tanks to the electrical earth of the plant.

258
Solar cylinders
IDRA PLUS DS - FLANGED with HIGH STORAGE CAPACITY
UAC

UAC - DHW outlet


EAF - Domestic cold water inlet
SB - Storage cylinder drain
ADAE
1 Tr
AE - S
AE - Electronical anode (optional)
RE - Electrical probe socket (not provided)
S - Probe
Tr - Thermometer
RE AD1 - Magnesium anode
S AD2 - Magnesium anode

AE2
AD S
AE - S

EAF

SB

Technical specifications

IDRA PLUS IDRA PLUS IDRA PLUS IDRA PLUS


DESCRIPTION UOM
DS 1000 DS 1500 DS 2000 DS 3000
Heat-exchangers lay-out Horizontal
Cylinder capacity 880 1430 1990 2959 l
Cylinder diameter with insulation 990 1200 1300 1450 mm
Cylinder diameter without insulation 790 1000 1100 1250 mm
Height with insulation 2095 2155 2470 2730 mm
Insulation thickness 100 mm
First magnesium anode (diameter/length) 32x700 mm
Second magnesium anode (diameter/length) - 32x400 32x700 mm
Flange diameter 290/220 mm
Probes sockets diameter 1/2” Ø
Electrical resistor (not provided) socket 1” 1/2 Ø
Cylinder maximum working pressure 10 8 bar
Net weight with insulation 175 283 443 543 kg
* With ΔT = 35 °C and primary temperature = 80 °C

9000
8500
8000
7500
7000
1,21 m²
6500
head losses (mbar)

6000
5500 0,8 m²
5000
4500
4000
SOLAR THERMAL

3500 2,63 m²
3000
2500
2000 6,34 m²
1500
1000
500 4,54 m²
0
0 1 2 3 4 5
flow rate (m3/h)

259
Multi-energy tank
HYBRID STOR - with STAINLESS STEEL COIL for DHW

Ŷ Triple coil multi-energy tank.


Ŷ Suitable for combination with boilers, heat pumps, solat thermal and
other energy sources.
Ŷ Ideal for heating and DHW production.
Ŷ DHW coil in AISI 316L stainless steel (corrugated pipe).
Ŷ Maximum working temperature 99 °C.

Multi-energy tank with stainless steel coil for DHW

DIMENSIONS BUFFER TANK ENERGY CLASS


HEAT LOSS
CODE MODEL with insulation CAPACITY
(W)
H × Ø (mm) (litres)

20051862 HYBRID STOR 430 1.650 × 810 431 60

20051863 HYBRID STOR 550 2.000 × 810 544 68 -

20051864 HYBRID STOR 750 1.855 × 1.000 762 156 -

20051866 HYBRID STOR 1000 2.180 × 1.000 928 175 -

For EXPANSION VESSELS see the dedicated section “ACCESSORIES FOR SOLAR THERMAL”.

Accessories

CODE DESCRIPTION

Specific accessories
4383270 Single-phase electrical resistance 1,5 kW, 1” 1/2
4383271 Single-phase electrical resistance 2,2 kW, 1” 1/2
4383272 Single-phase electrical resistance 3 kW, 1” 1/2
20020707 Three-phase electrical resistance 3,8 kW, 1” 1/2

N.B. Beretta strongly recommend to connect the tanks to the electrical earth of the plant.

260
Multi-energy tank
HYBRID STOR - with STAINLESS STEEL COIL for DHW

MC 80°C
UAC - DHW outlet
UAC
EAF - Domestic cold water inlet
MC2
RE - Socket for electrical heater
70°C M - Solar collector outlet
UR R - Solar collector return
RE M R
MC - Boiler flow
RC2 60°C
MC2 - Boiler 2 flow
R50 UR - CH outlet
MCON / R50
50°C
RC2 - Boiler 2 return
R50 - 50 °C water return
MCON - Flow condensing boiler
40°C RCON - Return condensing boiler
RCON / CB CB - Tank filling
EAF
SB - Tank drain
R30 30°C R30 - 30 °C water return
SB

Technical specifications

HYBRID HYBRID HYBRID HYBRID


DESCRIPTION UOM
STOR 430 STOR 550 STOR 750 STOR 1000
Tank capacity 431 544 762 928 l
Diameter with insulation 810 1000 mm
Height 1650 2000 1855 2180 mm
Insulation thickness 70 90 mm
Probes sockets diameter (boiler and solar system) 16 Ø mm
Thermal probe socket diameter 8 Ø mm
Thermometer socket diameter 1/2” M Ø
Upper primary coil water content 7,1 8,0 10,0 10,0 l
Lower primary coil water content 11,0 12,8 17,4 19,8 l
DHW coil water content 23,6 30,4 l
Upper primary coil exchange surface 1,17 1,31 1,72 1,72 m2
Lower primary coil exchange surface 1,80 2,10 2,90 3,34 m2
DHW coil exchange surface 4,5 5,8 m2
Upper primary coil absorbed power (*) 25,0 26,0 30,0 30,0 kW
Lower primary coil absorbed power (*) 52,0 62,0 76,0 92,0 kW
Tank maximum working pressure 3 5 bar
Primary coils maximum working pressure 10 bar
DHW coil maximum working pressure 6 bar
Net weight 168 195 239 269 kg
Gross weight (package included) 189 215,5 254 284,4 kg
(*) With ΔT = 35 °C and primary temperature = 80 °C

Head losses Head losses Head losses


UPPER COIL HYBRID STOR LOWER COIL HYBRID STOR DHW COIL HYBRID STOR
SOLAR THERMAL

900 900 900


750 - 1000 1000
750 800
800 800
550
700 550 430
700 700
430
HEAD LOSSES (mbar)

HEAD LOSSES (mbar)

HEAD LOSSES (mbar)

430 - 550
600 600 600
750-1000
500 500 500

400 400 400

300 300 300

200 200 200

100 100 100

0 0 0
0 1000 2000 3000 4000 5000 6000 0 1000 2000 3000 4000 5000 6000 0 1000 2000 3000 4000 5000 6000
FLOW RATE (l/h) FLOW RATE (l/h) FLOW RATE (l/h)

261
Combined storage tank
STOR C - TANK-IN-TANK

Ŷ Combined storage tank for the production/storage of DHW


and for heating supplement (tank-in-tank technology).
Ŷ Heat exchange solar coil as standard equipment.
Ŷ Seven fittings at different heights for the use of different types
of heat generators for the best stratification.
Ŷ Sacrificial magnesium anode included with the standard equipment.

Combined storage tank with tank-in-tank technology

DIMENSIONS STORAGE TANK DHW


HEAT LOSS
CODE MODEL with insulation CAPACITY CAPACITY
(W)
H × Ø (mm) (litres) (litres)

20014351 STOR C 800 1.870 × 1.000 800 with coil 240 156

20014352 STOR C 1000 2.196 × 1.000 980 with coil 285 175

Accessories

CODE DESCRIPTION

Specific accessories
20009244 Solar control box SUN B with probes
20009246 Solar control box SUN C with probes
20001492 Thermostatic mixing valve 1” with 3/4” adapter

N.B. Beretta strongly recommend to connect the tanks to the electrical earth of the plant.

262
Combined storage tank
STOR C - TANK-IN-TANK

UAC EAF
RL EAF - Domestic cold water inlet
MC1 MI1
RL - DHW recirculation
UAC - DHW outlet
MC1 - Boiler 1 flow (high temperature)
MC2 RI1
MC2 - Boiler 2 flow (low temperature)
RE RC1-2 - Boiler 1-2 return
M R
RI2/SB - System 2 return low temperature/
RC1-2
storage tank drain
MI2
MI2 - System 2 flow (low temperature)
R - Collector return
M - Collector outlet
RE - Socket for electrical heater
RI1 - System 1 return (high temperature)
MI1 - System 1 flow (high temperature)

RI2

Technical specifications

STOR C STOR C
DESCRIPTION UOM
800 1000
Heat-exchanger lay-out vertical
Storage tank capacity 560 695 l
Cylinder capacity 240 285 l
Diameter with insulation 1000 mm
Height 1870 2196 mm
Insulation thickness 100 mm
Flange diameter (external/internal) 280/205 mm
Probes sockets diameter 1/2” Ø
Coil water content 16 19 l
Coil exchange surface 2,80 3,16 m2
Coil absorbed power (*) 76 92 kW
DHW production (*) 800 1000 l/h
80 °C 515 550 l
DHW flow rate in 10’ with average ΔT
70 °C 500 515 l
35 °C and primary storage at
60 °C 415 450 l
Cylinder maximum working pressure 6 bar
Cylinder maximum working temperature 99 °C
Storage tank maximum working pressure 3 bar
Storage tank maximum working temperature 99 °C
Coil maximum working pressure 6 bar
Coil maximum working temperature 99 °C
Net weight 210 265 kg
Gross weight (package included) 225 281 kg
(*) With ΔT = 35 °C and primary temperature = 80-60 °C
Performance obtained using a correctly sized generator, set for a 4m3/h flow rate for the model STOR C 800 and for a 5m3/h flow rate for the model STOR C 1000.

1100

1000 STOR C 1000

900 STOR C 800

800
HEAD LOSSES (mbar)

SOLAR THERMAL

700

600

500

400

300

200

100

0
0 1000 2000 3000 4000 5000 6000
FLOW RATE (l/h)

263
Buffer tanks
STOR M AND STOR - with COIL or FLANGED

Ŷ Designed for forced circulation solar systems to supplement the


heating system.
Ŷ Production of DHW through an additional external heat exchange
module “ACS” (see dedicated pages).
Ŷ STOR M and STOR tanks are not suitable for DHW storage.
Ŷ Tank and coil maximum working temperature: 99°C.
Ŷ Eight fittings at different heights for the use of different types of heat
generators for the best stratification.
Ŷ Buffer tank and insulation are delivered in separate packages for STOR
models.
Ŷ STOR M models: supplied with heat exchange solar coil and insulation
as standard equipment.
Ŷ STOR models: through a standard flange it is possible the insertion of
an additional heat exchange solar coil, available as accessory.

N.B. This picture only represents STOR M. For STOR models see drawing at the following page.

Buffer tanks with coil or flanged

DIMENSIONS BUFFER TANK ENERGY CLASS


HEAT LOSS
CODE MODEL with insulation CAPACITY
(W)
H × Ø (mm) (litres)
BUFFER TANKS WITH COIL

20055207 STOR 300 M 1.635 × 700 270 93

20055208 STOR 500 M 1.775 × 850 476 126

20001406 STOR 1000 M 2.190 × 990 920 203 -

20001407 STOR 1500 M 2.165 × 1.200 1410 249 -

FLANGED BUFFER TANKS (WITHOUT COIL)

20001408 STOR 2000 2.480 × 1.300 2010 305 -

20001409 STOR 3000 2.720 × 1.450 2959 344 -

20001410 STOR 5000 2.870 × 1.800 5055 646 -

For EXPANSION VESSELS see the dedicated section “ACCESSORIES FOR SOLAR THERMAL”.

Accessories

CODE DESCRIPTION

Specific accessories
20055205 Tin coated copper coil kit 2,63 m2 (*) - 53kW - 1,74L - 10bar
4383089 Tin coated copper coil kit 4,54 m2 (*) - 91kW - 3,56L - 10bar
4383087 Tin coated copper coil kit 6,34 m2 (*) - 127kW - 5,10L - 10bar
(*) To use only with STOR 2000, STOR 3000 and STOR 5000.
N.B. Beretta strongly recommend to connect the tanks to the electrical earth of the plant.

264
Buffer tanks
STOR M AND STOR - with COIL or FLANGED
STOR M STOR
1 2 1 2

1 - Soft insulation (100mm thick)


in CFC-free polyurethane
2 - Vent/flow connection (Ø 1”1/4F)
3 4 3 - Flow/return connection (Ø 1”1/2F) 3 4
3 4 - Probes sockets (Ø 8mm) 3
5 - Solar collector flow connection (Ø 1”F)
6 - Solar collector return connection (Ø 1”F)
3 4 7 - Tank 3 4
5 3 8 - Coil 3
9 - Inspection flange
3 3
3 4 3 4

6
3 3
3
4 3 4

7 8 9 7

Technical specifications

STOR STOR STOR STOR STOR STOR STOR


SPECIFICATIONS UOM
300 M 500 M 1000 M 1500 M 2000 3000 5000
Heat-exchanger lay-out Vertical - - -
Buffer tank capacity 270 476 920 1410 2010 2959 5055 l
External diameter with insulation 700 850 990 1200 1300 1450 1800 mm
Height with insulation 1635 1775 2190 2165 2480 2720 2870 mm
Insulation thickness 100 mm
Flange diameter (external/internal) - - - - 290/220 290/220 290/220 mm
Probes sockets diameter 8 mm
Coil water content 10,4 10,4 14,6 21,6 - - - l
Coil heat-exchange surface 1,8 1,8 2,6 3,8 - - - m2
Coil absorbed power (*) 43 45 68 99 - - - kW
Tank maximum working pressure 3 bar
Coil maximum working pressure 6 6 6 6 - - - bar
Net weight with insulation 115 140 225 285 345 415 570 kg

(*) With ΔT = 35 °C and primary temperature = 80 °C

STOR M HEAD LOSSES HEAD LOSSES OF STOR EXCHANGE COIL (ACCESSORY)


650 8000
600 7500
550 7000
HEAD LOSSES (mbar)

HEAD LOSSES (mbar)

STOR 1500 M 6500


SOLAR THERMAL

500
6000
450 5500
400 5000
350 4500
STOR 1000 M STOR 2000-3000-5000
STOR 300 M 4000
300
STOR 500 M 3500
250
3000
200 2500
150 2000

100 1500
1000
50
500
0 0
0 1 2 3 4 5 0 1 2 3 4 5

FLOW RATE (m3/h) FLOW RATE (m3/h)

265
Heat exchange groups – solar side
STS 50 LOW ENERGY

Ŷ Heat-exchange group, solar-side.


Ŷ Suitable for medium-sized installations.
Ŷ Wall-hung installation.
Ŷ Suitable for two buffer tanks.
Ŷ Highly effective thanks to two heights stratification.
Ŷ Built-in solar control-box as standard.
Ŷ Built-in low energy circulators as standard.
Ŷ Electronic management (PWM) of the circulator on the solar side.
Ŷ Motorized mixing valve.
Ŷ Built-in plates heat-exchanger in AISI 316 as standard.
Ŷ Equipped with thermal insulation.
Ŷ Equipped with electronic flow-meter for flow display (buffer tank side).

Solar side heat-exchanger module

DIMENSIONS MANAGED
CODE MODEL H×L x D COLLECTORS
(mm) SURFACE (m2)

20083494 STS 50 LOW ENERGY 600 × 400 x 250 50

266
Heat exchange groups – solar side
STS 120 LOW ENERGY

Ŷ Heat-exchange group, solar-side.


Ŷ Suitable for large-sized installations.
Ŷ Wall-hung installation.
Ŷ Suitable for two buffer tanks.
Ŷ Highly effective thanks to two heights stratification.
Ŷ Built-in solar control-box as standard.
Ŷ Built-in low energy circulators as standard.
Ŷ Electronic management (0-10V) of the circulator on the solar side.
Ŷ Motorized mixing valve.
Ŷ Equipped with electronic flow-meter for flow display (buffer tank side).
Ŷ Equipped with thermal insulation.
Ŷ Built-in plates heat-exchanger in AISI 316 as standard.

Solar side heat-exchanger module

DIMENSIONS MANAGED
CODE MODEL H×L x D COLLECTORS
(mm) SURFACE (m2)

20083495 STS 120 LOW ENERGY 835 × 475 x 226 80

SOLAR THERMAL

267
Heat exchange groups – DHW
ACS 35 LOW ENERGY/ACS 40 LOW ENERGY

Ŷ Heat-exchange group for the instantaneous production of DHW.


Ŷ Suitable for small and medium-sized installations.
Ŷ Wall-hung installation.
Ŷ Built-in control box as standard (ACS 40).
Ŷ Built-in thermostatic mixing valve as standard (ACS 35).
Ŷ Electronic temperature control (ACS 40).
Ŷ Low return temperature on primary circuit.
Ŷ Built-in low energy circulator as standard.
Ŷ Built-in plates heat-exchanger in AISI 316 as standard.
Ŷ Possibility of cascade installation.
Ŷ Possibility to install the recirculation kit.
Ŷ Electronic management (PWM) of the circulator on the buffer tank
(primary circuit) (ACS 40).

Heat-exchange modules for DHW production

DIMENSIONS MANAGED
CODE MODEL H×L x D COLLECTORS
(mm) SURFACE (m2)

20083489 ACS 35 LOW ENERGY 600 × 430 x 250 38

20083491 ACS 40 LOW ENERGY 820 × 480 x 195 44

Accessories

CODE DESCRIPTION

20083502 Recirculation kit ACS 35(1)


20083500 Cascade kit ACS 35
20083503 Recirculation kit ACS 40(2)
20083501 Cascade kit 2 ACS 40(3)
20084362 Cascade kit 3 ACS 40(3)

(1) Use only one recirculation kit both in case of ACS 35-single application and ACS 35-cascade application.
(2) Use the recirculation kit only in case of ACS 40-single application.
(3) The cascade kit ACS 40 includes the recirculation kit.

268
Heat exchange groups – DHW
ACS 35 LOW ENERGY/ACS 40 LOW ENERGY

Technical specifications

SPECIFICATIONS ACS 35 UOM


Thermal power absorbed with storage cylinder at 50°C and DHW water delivery at 10-45°C 54 kW
Water draw at 10-45°C with storage cylinder at 50°C 22 l/min
Thermal power absorbed with storage cylinder at 55°C and DHW water delivery at 10-45°C 68 kW
Water draw at 10-45°C with storage cylinder at 55°C 28 l/min
Thermal power absorbed with storage cylinder at 60°C and DHW water delivery at 10-40°C 80 kW
Water draw at 10-40°C with storage cylinder at 60°C 38 l/min
Maximum flow-rate primary 1700 l/h
Minimum permissible temperature, DHW circuit 2 °C
Maximum operating temperature 90 °C
Maximum operating pressure, primary circuit 10 bar
Opening pressure, primary circuit non-return valves 28 mbar
Opening pressure, DHW circuit non-return valves 28 mbar
Electrical power consumption 45 W
Power supply voltage 230 V
Power supply frequency 50-60 Hz
Index of protection 54 IP
Net weight 19,1 kg
Water capacity 6,1 l

DHW production graph

Temperatura
DCW di ingresso
inlet temperature AFS 10°C
10°C Temperatura
DCW di ingresso
inlet temperature AFS 20°C
20°C
45 50
Produzione acqua potabile ACS (l/min)

40 45
°C
Produzione ACS (l/min)

2
°C

÷4 °C 40
10
2

35 5
÷4

4
0÷ °C
20

1 °C 35 4 5
8
÷4 2 0÷ °C
30 10 °C 4 8
0 30 0÷ °C
÷5 2 0
10 5
25
°C 20÷
55 25 °C
÷ 55
10 ÷
20 20
20

15 15
40 45 50 55 60 65 70 40 45 50 55 60 65 70
Temperatura
Temperature of waterprelievo
from accumulo
storage(°C)
cylinder (°C) Temperatura
Temperature of waterprelievo
from accumulo
storage (°C)
cylinder (°C)
SOLAR THERMAL

N.B. Correct functioning of the product is only guaranteed if the primary circuit inlet temperature is at least 5°C higher than the DHW setpoint.

269
Heat exchange groups – DHW
ACS 160 LOW ENERGY

Ŷ Heat-exchange group for the instantaneous production of DHW.


Ŷ Suitable for large-sized installations.
Ŷ Built-in control box as standard.
Ŷ Low return temperature on primary circuit.
Ŷ Two built-in low energy circulators as standard.
Ŷ Electronic management (0-10 V) of the circulator on the buffer tank
(primary circuit).
Ŷ Modulating pump for DHW recirculation.
Ŷ Built-in plates heat-exchanger in AISI 316 as standard.

Heat-exchange modules for DHW production

DIMENSIONS MANAGED
CODE MODEL H×L x D COLLECTORS
(mm) SURFACE (m2)

20083492 ACS 160 LOW ENERGY 1.140 × 1.000 x 500 162

270
Solar thermal accessories
ELECTRIC AND HYDRAULIC KITS

Electronic solar control-boxes

CODE DESCRIPTION

20039694 Thermostat SUN 1 with probes for boilers


20009244 Solar control box SUN B with probes
20009246 Solar control box SUN C with probes
20008787* Probe for solar control-boxes SUN B and SUN C
* The solar control-boxes are already equipped with probes.

Diverter valves and thermostatic valves

CODE DESCRIPTION

1150529 Thermostatic mixing valve 3/4”


20001492 Thermostatic mixing valve 1” with 3/4” adapter
20001491 Motorized 3-ways diverter valve**
20035644 Solar diverter valve
** Not suitable for solar circuit

Hydraulic group

CODE DESCRIPTION

20096925 Low Energy hydraulic group return (residual head 7,5m)(A)


20096926 Low Energy hydraulic group flow/return (residual head 7,5m)(A)
Connection bends kit for hydraulic group
20027382
(residual head 4,5m, 6,5m, 7,5m) - cylinder
Connection bends kit for hydraulic group
20009438
(residual head 11m, 14,5m) - cylinder
Low Energy hydraulic group flow/return (residual head 14,5m)(B) +
20075392
solar control box SUN C
Solar control fixing (connected with hydraulic group return 4,5m) -
20042105
cylinder
SOLAR THERMAL

Connection bend kit for hydraulic group return


20042106
(residual head 4,5m) - cylinder

(A) Low Energy hydraulic groups with low consumption modulating pump, without solar controller.
(B) Low Energy hydraulic groups with low consumption modulating pump, with solar controller.

271
Solar thermal accessories
ELECTRIC AND HYDRAULIC KITS

Expansion vessels

CODE DESCRIPTION

1150489 Expansion vessel 18L


1150509 Expansion vessel 24L
1150519 Expansion vessel 35L
1150499 Flex and support for expansion vessel (18-24L)
20001448 Expansion vessel 50L
20001449 Expansion vessel 100L
20009237 Expansion vessel 300L

Glycol and accessories

CODE DESCRIPTION

20009190 2,5 kg glycol*


1150549 5 kg glycol*
1150559 10 kg glycol*
20 kg inorganic premix glycol specific
20094030
for SCV-25 evacuated tube collector
20001453 Flow regulator 12 l/min
20011538 Flow regulator 20 l/min
20026577 Manual air vent
20001454 Solar filling pump

* Not suitable for SCV-25 evacuated tube collector.

272
Solar thermal accessories
ELECTRIC AND HYDRAULIC KITS

Stainless steel and copper pipes

CODE DESCRIPTION

1150619 Flexible pipe Ø16-15m connecting collector to cylinder


Fittings kit for flexible stainless steel pipes
20001452
(connection with 2,5 m2 tray or Al frame collectors, and with solar cylinder)
20022233 Fittings kit for flexible stainless steel pipes (connection with SCI-25N and with solar cylinder)
20021321 Fittings for copper pipes (connection with SCI-25N and with solar cylinder)
20029277 Compensation joint kit
20001451 Flexible pipe ø 16-20 m connecting collector to cylinder
20007290 Fittings SCF-20N for flexible stainless-steel pipes
20027289 Fittings SCV-25 for flexible stainless-steel pipes
20014661 Fittings kit for copper pipes (connection with 2,5 m2 tray or Al frame collectors, and with solar cylinder)
20108734 Female ending fitting kit

= NEW (the green rectangle identifies a new code)

SOLAR THERMAL

273
Natural circulation system
NB-SOL - COMPLETE NATURAL CIRCULATION SYSTEM

Ŷ Natural circulation system for the production of DHW, performing best


in areas with high levels of sunlight and mild winters.
Ŷ Ready-to-be-installed system, complete with collector(s), cylinder,
SOLAR fittings and glycol.
KEYMARK Ŷ Blue selective absorber surface.
certification Ŷ Ease of functioning: no need of any additional components such as a
circulator or an electronic controller.
Ŷ Complete with anti-irradiation film to be taken away at the activation of
the system.
Ŷ Collector stagnation temperature: 192 °C.
Ŷ Magnesium anode included with the standard equipment.
Ŷ DHW and solar safety valves (10 bar and 2,5 bar).
Ŷ Enamelled double-walled steel cylinder with polyurethane insulation.
Ŷ Electrical resistance and mixing valve available as accessories.
Ŷ NB-SOL system can be matched with combi wall-hung boilers.
Ŷ Shock-proof plastic cover protects the cylinder.
Ŷ Collectors conform to the EN 12975 standard.

Complete natural circulation systems* - for FLAT ROOF

CYLINDER COLLECTORS COLLECTORS


NUMBER OF
CODE MODEL CAPACITY DIMENSIONS TOTAL AREA
COLLECTORS
(litres) H X L (mm) (m2)

20100366 NB-SOL 150/1 TP** 1 150 1.818 x 1.097 1,91

20100367 NB-SOL 200/1 TP** 1 200 1.818 x 1.097 1,91

20100368 NB-SOL 220/2 TP** 2 220 1.818 x 2.194 3,82

20100369 NB-SOL 300/2 TP** 2 300 1.818 x 2.194 3,82

20100370 NB-SOL 300/3 TP** 3 300 1.818 x 3.291 5,73

NB: The angle of inclination of the solar collector is 30°.

Complete natural circulation systems* - for PITCHED ROOF

CYLINDER COLLECTORS COLLECTORS


NUMBER OF
CODE MODEL CAPACITY DIMENSIONS TOTAL AREA
COLLECTORS
(litres) H X L (mm) (m2)

20098606 NB-SOL 150/1 TI** 1 150 1.818 x 1.097 1,91

20098607 NB-SOL 200/1 TI** 1 200 1.818 x 1.097 1,91

20099128 NB-SOL 220/2 TI** 2 220 1.818 x 2.194 3,82

20099129 NB-SOL 300/2 TI** 2 300 1.818 x 2.194 3,82

20099130 NB-SOL 300/3 TI** 3 300 1.818 x 3.291 5,73

* Brackets are included in NB-SOL system.


** It is recommended to install a DHW expansion vessel according to the cylinder capacity.

274
Natural circulation system
NB-SOL - COMPLETE NATURAL CIRCULATION SYSTEM
Packages

CODE MODEL

20111165* One package containing 2 pcs of NB-SOL 150/1 TP

20111254* One package containing 2 pcs of NB-SOL 200/1 TP

20111322** One package containing 2pcs of code 20098606 NB-SOL 150/1 TI

20111344** One package containing 2pcs of code 20098607 NB-SOL 200/1 TI


* NB: brackets kits are not included. They must be ordered separately.
** Brackets kits are included.

Accessories

CODE DESCRIPTION

20111166 Brackets kit for flat roof (8pcs)


1150529 Thermostatic mixing valve 3/4”
20001492 Thermostatic mixing valve 1” with 3/4” adapter
20006605 Electrical resistance 1,5 kW
1150489 18 litres solar expansion vessel
1150509 24 litres solar expansion vessel

= NEW (the green rectangle identifies a new code)

SOLAR THERMAL

275
Natural circulation system
NB-SOL - COMPLETE NATURAL CIRCULATION SYSTEM

Dimensions and weight


NB-SOL TP

H
30°

L P

NB-SOL TI

P
P2

P1

Technical specifications
NB-SOL TP NB-SOL TI
DESCRIPTION 150/1 200/1 220/2 300/2 300/3 150/1 200/1 220/2 300/2 300/3 UDM
Empty weight 112 136 162 198 236 94 122 143 193 200 kg

Gross weight 274 352 401 496 597 256 338 382 491 500 kg

L 1310 13101 2400 2400 3500 1300 1300 2410 2410 3510 mm

P 2310 2310 2310 2310 2310 270 270 360 360 360 mm

P1 - - - - - 1965 1965 1619 1619 1619 mm

P2 - - - - - - - 332 332 332 mm

H 1130 1130 1130 1130 1130 720 720 720 720 720 mm

276
03/2016 EN-INT Rev. 0.0

Trading Address:
Via Risorgimento, 23/A
23900 LECCO
Italy
Tel. +39 0341 277111
Fax +39 0341 277263
info@berettaboilers.com
www.berettaboilers.com

In order to improve its products, Beretta


reserves the right to modify the characteristics
and information contained in this catalogue at any
time and without prior notice.
This catalogue, therefore, cannot be considered as
contractually binding on third parties.

You might also like