You are on page 1of 51

INMARSAT-C MOBILE EARTH STATION

FELCOM 15
Installation Manual
TABLE OF CONTENTS
SAFETY INSTRUCTIONS .............................................................................................................i
EQUIPMENT LISTS......................................................................................................................ii
SYSTEM CONFIGURATION .......................................................................................................iv
1. MOUNTING THE UNIT..........................................................................................................1
1.1 Antenna Unit.................................................................................................................1
1.2 Terminal Unit ................................................................................................................4
1.3 Distress Alert/Received Call Unit IC-305/Alarm Unit IC-306 ........................................6
1.4 Printer PP-510 (option)/EGC Printer PP-505 (option) ..................................................7
1.5 AC/DC Power Supply Unit PR-240 (option) .................................................................7
1.6 Junction Box IC-315 .....................................................................................................8
2. WIRING .................................................................................................................................9
2.1 Antenna Cable Connector at the Terminal Unit..........................................................10
2.2 Distress Alert/Received Call Unit IC-305....................................................................13
2.3 Alarm Unit IC-306 .......................................................................................................14
2.4 Junction Box IC-315 ...................................................................................................15
3. INITIAL SETTING................................................................................................................16
3.1 Setting the IMN (INMARSAT MOBILE NO.)...............................................................16
3.2 Setting for External Equipment...................................................................................17
4. INSTALLATION OF GPS BOARD (OPTION).....................................................................18
5. CHANGING POWER SUPPLY SPECIFICATIONS ............................................................21
PACKING LISTS....................................................................................................................... A-1
OUTLINE DRAWINGS.............................................................................................................. D-1
INTERCONNECTION DIAGRAM ............................................................................................. S-1

www.furuno.com
All brand and product names are trademarks, registered trademarks or service marks of their respective holders.

Downloaded from www.Manualslib.com manuals search engine


The paper used in this manual
is elemental chlorine free.

・FURUNO Authorized Distributor/Dealer

9-52 Ashihara-cho,
Nishinomiya, 662-8580, JAPAN

Telephone : +81-(0)798-65-2111
Fax : +81-(0)798-65-4200

All rights reserved. Printed in Japan A : DEC . 2002


G2 : JAN . 17, 2012
Pub. No. IME-56350-G2
(YOSH ) FELCOM15 *00080935116*
*00080935116*
* 0 0 0 8 0 9 3 5 1 1 6 *

Downloaded from www.Manualslib.com manuals search engine


SAFETY INSTRUCTIONS

WARNING CAUTION
Do not open the equipment
Confirm that the power supply voltage
unless totally familiar with
is compatible with the voltage rating
electrical circuits and
of the equipment.
service manual.
Connection to the wrong power supply
ELECTRICAL Only qualified personnel can cause fire or equipment damage. The
SHOCK should work inside the
voltage rating appears on the label at the
HAZARD equipment.
rear of the terminal unit.

Do not approach the ra-


dome closer than 60 cm
Use the correct fuse.
when it is transmitting.
Use 10 A fuse (defalt setting) for 12 VDC
Microwave radiation can
power supply, or replace the fuse to 5 A
cause severe injury or illness.
(supplied as spare parts) with 24 VDC.
Radiation level:
2
10 W/m at 60 cm
Use of wrong fuse can result in damage to
the equipment.
Turn off the power at the
mains switchboard before Keep the following compass safe
beginning the installation. distances.
Post a sign near the switch
Standard Steering
to indicate it should not be
Antenna Unit IC-115 0.30 m 0.30 m
turned on while the equip-
ment is being installed. Terminal Unit IC-215 0.70 m 0.40 m
Printer PP-510 1.00 m 0.80 m
Fire, electrical shock or Junction Box IC-315 1.00 m 0.70 m
serious injury can result if the Distress Alert/
power is left on or is applied Received Call Unit IC-305 0.50 m 0.30 m
while the eqiuipment is being Alarm Unit IC-306 0.50 m 0.30 m
installed. EGC Printer PP-505 2.05 m 1.40 m
AC/DC Power Supply Unit
0.90 m 0.60 m
PR-240
Mini keyboard 0.30 m 0.30 m

Attach securely protection


earth to the ship's body.

The protection earth is required


to the power supply to prevent
electrical shock.

i
Downloaded from www.Manualslib.com manuals search engine
EQUIPMENT LISTS
Standard Supply
Name Type Code No. Qty Remarks
Antenna Unit IC-115 - 1
Terminal Unit IC-215 - 1
Distress Alert/
IC-305 - 1
Received Call Unit
Alarm Unit IC-306 - 1
Junction Box IC-315 - 1 w/CP16-02501*
CP16-02101 004-439-060 For 30 m antenna cable (w/o armor)*
CP16-05001 001-101-960 For 30 m antenna cable (w/armor)*
1 set
CP16-02111 004-439-070 For 50 m antenna cable (w/armor)*
CP16-02121 004-439-080 For 100 m antenna cable (w/armor)*
CP16-02301 (for IC-215)*,
Installation CP16-02300 000-043-433 1 set
CP16-02302 (for keyboard)*
Materials
CP16-02201 004-438-890 1 set For IC-305/306
TP5FBAW-5DFB 000-159-523-11 30 m antenna cable (w/o armor)
5D-FB-CV-NP 000-173-676-10 30 m antenna cable (w/armor)
1
8D-FB-CV 000-168-241-10 50 m antenna cable (w/armor)
12D-SFA-CV 000-138-866 100 m antenna cable (w/armor)
Accessories FP16-00600 1 set Mini keyboard (G84-4100PPAUS), FD
000-043-434
(FP16-00601)
Spare Parts SP16-01301 004-439-370 1 set Fuse*

Optional Supply
Name Type Code No. Qty Remarks
FD-ROM 16-5-0164 004-438-920 1 set
GPS Board OP16-47 001-017-110 1 set
GPS Board Kit OP16-48 000-011-766 1 set
RF Cover (GPS) OP16-49 000-011-767 1
EGC Printer PP-505 - 1
Printer PP-510 - 1 w/CP16-01200*
AC/DC Power Supply Unit PR-240 - 1 w/CP24-00151*
000-560-452 For junction box, 10m
000-103-868 For junction box, 20m
CO-SPEVV-SB-C
5-pair cable 000-103-869 1 For junction box, 30m
0.2x5P
000-132-829 For junction box, 40m
000-132-828 For junction box, 50m
IC-307 (2units), FD-ROM (for
SSAS Modification Kit** OP16-33 000-043-492 1
RFCON CPU, for TERM CPU)
SSAS Alert Unit** IC-307 000-043-473 1 w/CP16-03101, FP16-00901
For distress alert/received call
OP16-27 004-448-000 1
Flush Mounting Kit unit, alarm unit
OP16-28 004-448-010 1 For SSAS alert unit
ALC (FFA) Modification Kit* OP16-26 004-439-840 1
Russian Language Kit OP16-43 004-449-590 1 For IC-215
PC Terminal Software OP16-45 004-449-600 1 Russian Language
Antenna Mounting Kit CP16-03701 004-555-000 1 set

ii
Downloaded from www.Manualslib.com manuals search engine
Antenna Bracket CP16-03702 001-016-260 1 See page D-14.
Antenna Mounting Pipe CP16-03703 001-014-510 1
*: See packing lists at the back of this manual.
**: The SSAS modification kit is required for the SSAS. For installation of three IC-307s, additional SSAS
alert unit is necessary.

iii
Downloaded from www.Manualslib.com manuals search engine
SYSTEM CONFIGURATION
ANTENNA
UNIT
IC-115

DGPS

POWER SUPPLY EGC Printer** 24 VDC


100-115/200-230 VAC PP-505
TERMINAL UNIT
1φ, 50/60 Hz IC-215
AC-DC Power Supply Personal
Computer Printer
PR-240
(PC/AT compatible)
POWER SUPPLY GPS Board
12/24 VDC OP16-47 Shipboard LAN (Ethernet)

Printer**
PP-510
* For 12 VDC power supply,
DC-DC converter is Mini Keyboard Distress Alert/
required to use PP-510.
Received Call Unit
IC-305
Distress Message Controller
24 VDC DMC-5 JUNCTION
BOX Alarm Unit
OR
IC-315 IC-306
SSAS Alert Unit* SSAS Alert Unit*
IC-307 IC-307
Navigator
(Max. 3 units)

*: At least two SSAS Alert Units are required.


**: Mandatory for EGC operation as required by IMO RES. A.664(16). : Standard Supply
: Option
CATEGORY OF UNITS : Local Supply

Unit Category
Terminal Unit Protected from weather
Antenna Unit Exposed to weather
Other Units Protected from weather

iv
Downloaded from www.Manualslib.com manuals search engine
1. MOUNTING THE UNIT

NOTICE
Do not apply paint, anti-corrosive sealant or contact spray to coating
or plastic parts of the equipment.

Those items contain organic solvents that can damage coating and plastic
parts, especially plastic connectors.

1.1 Antenna Unit


Mounting Location
• Mount the omnidirectional antenna unit high atop a mast clear of stays and the turning
diameter of a radar antenna. The ideal mounting location would be where no obstacle
appears in the fore and aft directions down to -5º and down to -15º in the port and
starboard directions. This concept is illustrated in the figure below. Shadow sector of the
antenna mast, whip antenna, etc. should be within 2 degrees at one meter from the
antenna unit.
ANTENNA UNIT

5 5 15 15

Antenna unit mounting location


• If both Inmarsat-B/F and Inmarsat-C ship earth stations are installed, separate the
Inmarsat-B/F antenna at least 8 m from the Inmarsat-C antenna.
• Separate the antenna unit from an S-band radar as follows:
Install above this line

INSTALLTION
ZONE
PROHIBITED
2m ZONE
1.5 m
15

2m
5m
S-band radar

HORIZONTAL LINE
S-band radar and installation area

1
Downloaded from www.Manualslib.com manuals search engine
1. MOUNTING THE UNIT

• The allowable vibration level as specified by Inmarsat is as shown in the table below.
Allowable vibration level

Frequency Level
2 to 10 Hz 2.54 mm Peak Amplitude
10 to 100 Hz 9.8 m/s² Peak Acceleration
• Avoid the location near funnels and stacks; smoke and soot on the radome can lower
signal level.
• Separate the antenna unit 5 m from HF, VHF or 27 MHz antenna.

Mounting
The antenna cable is available in lengths of 30 m, 50 m and 100 m (see table below).
Cable length Type Remarks
30 m (no armor) TP5FBAW-5DFB TNC connector at both ends
30 m (w/armor) 5D-FB-CV-NP
50 m (w/armor) 8D-FB-CV N connector on one end (antenna side)
100 m (w/armor) 12D-SFA-CV
To mount the antenna unit, an exclusive pipe is necessary.

Note 1: Do not shorten these cables. Interference can result, affecting performance.
Note 2: To mount the antenna unit with the optional antenna mounting kit (Type:
CP16-03701, Code No.: 004-555-000), see page D-13.

Locally prepare an antenna mast with a ground stud (M6 stainless steel bolt welded to
antenna mast) and mounting pipe with threads and plate (See the outline drawing of the
mounting plate shown on the next page.) Weld the mounting pipe to the antenna mast.
The distance between the stud and the earth terminal on the antenna unit should be within
340 mm, which also is the length of the supplied earth wire.

2
Downloaded from www.Manualslib.com manuals search engine
1. MOUNTING THE UNIT

12-S

20
1x14 UNS
200
Earth wire (340 mm)

100
Ground stud
Mounting pipe

35-S 12-S 25-S


,
,
Welding 50

Antenna mast

6
.4
25
Mounting pipe and antenna mast

For how to wire the antenna cable, see "Installation and Replacement of Antenna Unit",
included with the antenna unit.

3
Downloaded from www.Manualslib.com manuals search engine
1. MOUNTING THE UNIT

1.2 Terminal Unit


Select the following place to install the terminal unit.
• The temperature and humidity should be moderate and stable.
• For maintenance and checking purposes, leave sufficient space at the sides and rear of
the unit and leave slack in cables.

Mounting
Tabletop mounting
1. Fix the hanger on a table with four tapping screws (5x20, supplied).
282

240 + 0.5
4-φ7

80 + 0.5

29 + 3

Terminal unit, tabletop mounting


2. Screw knobs and washers to terminal unit loosely.
3. Set the terminal unit to the hanger and tighten knobs.

Flush mounting
Use local supplied pan head screws (M4x20) when the thickness of the bulkhead is from 11
to 14 mm. For bulkhead which exceeds 14 mm in thickness the length of the pan head
screws should be bulkhead thickness A +7.8±2 mm. Also the length of B should be max. 8
mm (B≤8 mm).
B A

Bulkhead, sectional view

1. Prepare a cutout in the mounting location whose dimensions are as shown on next
page.
2. Fix the display unit by six pan head screws M4x20, inserting from the inside of the
bulkhead. Refer to the outline drawing at the end of this manual.

4
Downloaded from www.Manualslib.com manuals search engine
1. MOUNTING THE UNIT

38 80 120

M4x20

228±0.5
223±1
230±0.5
4.5

273±1 4-R2.25

58
Dimensions for flush mounting

Keyboard
15
1. Attach the function key label ( INM-C 12 ) to the location shown below.
Function key label (supplied)

Esc F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 Num Prt Sc Scroll Pause


Lock Lock
F11 F12 Sys Rq Break

_ I
! @ # $ % ^ & ( ) + Home
Back-
1 2 3 4 5 6 7 7 8 8 9 9 0 - = space

Q W E R T Y U I O P { } Pg Up
Tab 4 5 5 6 - [ ] \

Caps A S D F G H J K L : " Pg Dn
Lock Enter
1 2 3 ; + ' Enter

Z X C V B N M < > ? End


Shift 0 , . . / / Shift

Ctrl Alt ~ Alt Ins Del


,
Ctrl Fn

2. Attach four fasteners (small, supplied) to the bottom of the keyboard.


3. Attach four fasteners (large, supplied) to the small fasteners attached in step 3.
4. Peel the paper from four fasteners.
5. Fix the keyboard to the mounting place.

5
Downloaded from www.Manualslib.com manuals search engine
1. MOUNTING THE UNIT

1.3 Distress Alert/Received Call Unit IC-305/


Alarm Unit IC-306

ALARM ALARM
ACK ACK

Distress alert/received call unit IC-305 Alarm unit IC-306

Bulkhead mounting
1. Remove four screws from the unit to separate the bottom chassis from the top cover.
2. Fix the bottom chassis to the mounting location with four tapping screws (supplied).
3. Cable can be entered from bottom or rear panel. Select suitable entrance. For rear
panel entrance, change the clamp orientation as follows.
a) Unfasten two screws to remove the cable clamp.
b) Turn the clamp 90 degrees.
c) Refasten two screws removed at step a) to fix the clamp.
Unfasten these screws.
Refasten screws.

Rotate.

Cable clamp, rotating


4. Run the interconnection cable thru a cable entrance and connect it to terminal board.

Flush mounting
The optional flush mounting kit OP16-27 (Code No. 004-448-000) is required.
Name Type Code No. Qty Remarks
Fixture 16-018-4201-1 100-317-841 1
Pan head screw M3x6 000-800-362 4
Self-tapping screw 4x16 000-162-605-10 4
1. Cut out the mounting position referring to the outline drawings at the back of this
manual.
2. Fix the unit to the fixture with four pan head screws (supplied as the option kit).
3. Fasten four tapping screws (ø5, supplied as the option kit) to mount the fixture to the
mounting position.

6
Downloaded from www.Manualslib.com manuals search engine
1. MOUNTING THE UNIT

1.4 Printer PP-510 (option)/


EGC Printer PP-505 (option)
PP-510 (option)
Lay the printer on a table and fix it with printer fixtures 1 and 2.
Attach labels appropriately; right side of printer for the compass safety distance label and
front of printer for INMAR C label.
INMARSAT label "C"
Printer fixture 2
Printer
fixture1

Label for
200 Compass safety distance
405

Printer PP-510
PP-505 (option)
1. Fix the hanger on a table with four tapping screws.
2. Screw knobs into printer.
3. Set printer to hanger and tighten knobs.

1.5 AC/DC Power Supply Unit PR-240 (option)


Fix the unit on a table with four tapping screws.

272 + 1

100 + 1

AC/DC power supply unit, dimensions

7
Downloaded from www.Manualslib.com manuals search engine
1. MOUNTING THE UNIT

1.6 Junction Box IC-315


The junction box IC-315 is connected to the terminal unit by using the cable assy 16S0344
(2 m, attached to the junction box). Install the junction box within 2 m from the terminal unit.

1. Remove four screws from the unit to separate the bottom chassis from the top chassis.
2. Fix the bottom chassis to the mounting location with four tapping screws (4x16:
supplied).
3. Connect the cables appropriately referring to Chapter 2.
120 + 0.5

70 + 0.5

Junction box IC-315, dimensions

8
Downloaded from www.Manualslib.com manuals search engine
2. WIRING

24 VDC

VCTF-0.75x3C
(5 m)
Printer
For cable w/armor PP-510
0.34 m
Cable Assy.
Ground wire
TPA5FB0.4NJ5FBA-5DFB
TP5FBAW-5DFB,
5D-FB-CV-NP, 30 m 30 m (No armor)
8D-FB-CV, 50 m Connector at both 16S0184,
12D-SFA-CV, 100 m ends 3m
Connector at one end
Mini keyboard
TNCP-NJ G84-4100PPAUS
connector DGPS
(Supplied)
LAN cable
Connector N-P-5DFB (10BaseT, local supply)
N-P-8DFB Remove the cover to use.
N-P-12DSFA
(Supplied, local arrangement)

Copper strap
MJ-A3SPF0018-050Z
1.2 m

CAUTION Power supply


24 VDC
The terminal unit is shipped with a 15 A
fuse in its power cable. This fuse is for use
with a 12 VDC power supply.

For a 24 VDC power supply, replace the


fuse with a 7A fuse (supplied). Attach the
"7A" label to the fuse holder on the power
cable. Use of a wrong fuse can damage the
equipment.
Junction Box
IC-315
* * * *
CO-SPEVV-SB-C 0.2x5p
(option)
or TTYCS-4
(Japanese * *
Industrial *
Standards)
#: When connecting with the Distress Message DMC-5# Navigator
Controller DMC-5, set the DMC-5's function for
"SES (EGC)," in the SET UP EGC/SES menu,
referring to chapter 7 "SYSTEM SETTINGS" in the Distress alert/ Alarm unit
operator's manual for DMC-5 (OME-5540). Received call IC-306
unit
Further, connect a jumper wire between TB5-#1 IC-305
and TB5-#3 on the DMC-5.

Wiring of FELCOM 15

9
Downloaded from www.Manualslib.com manuals search engine
2. WIRING

2.1 Antenna Cable Connector at the Terminal Unit


5D-FB-CV-NP (30 m)
Outer Sheath Inner Sheath
Armor Braided Shield

Remove the outer sheath, armor and inner


50 15 sheath by the dimensions shown.

Cover with heat-shrink tubing and heat.


Washer
Set the nut, washer, gasket, clamp onto
cable as shown.
30
Clamp - Be careful not to damage the braided
Gasket shield.
Nut
3.5
Fold back the braided shield onto the clamp
Insulator
Core and trim the shield as shown.
5
Make the length of insulator 3.5 mm and the
Cut braided shield here. length of the core 5 mm.
- Be careful not to damage the core.

Center Pin Set the center pin to the core and solder
the pin from the hole in the pin.
(Pull the pin with approx. 1 kg of force to
check strength of solder joint.)
- Be sure the solder is flush with surface of
Solder here.
pin.
- Be sure there is no gap between center
pin and insulator. Do not push the center
pin into the insulator.
- Do the soldering as quickly as possible so
as not to deform the insulator.

Insulator Ring

Set the ring and insulator ring onto the


cable.
Ring

Shell

Set the shell to the cable then turn the nut


to tighten. (Do not tighten by turning shell.)
- Use a wrench or the like to tighten the nut
securely.
Nut

How to fabricate antenna cable 5D-FB-CV-NP

10
Downloaded from www.Manualslib.com manuals search engine
2. WIRING

8D-FB-CV (50 m)
Outer Sheath Dimensions in millimeters.
Armor Inner Sheath Shield Remove outer sheath and armor by the
dimensions shown left.
Expose inner sheath and shield by the
50 30 dimensions shown left.

Cover with heat-shrink tubing and heat.


Remove insulator and core by 10 mm.

30 10

Twist shield end.

Slip on clamp nut, gasket and clamp as shown


left.
Clamp Gasket Clamp
Nut (reddish
brown)
Aluminum Foil

Fold back shield over clamp and trim.

Trim shield here.

Cut aluminum foil at four places, 90 from one


Insulator another.

Fold back aluminum tape foil onto shield and trim.


Trim aluminum
tape foil here.

1
Expose the insulator by 1 mm.
5
Expose the insulator by 5 mm.

Pin
Clamp Nut Slip the pin onto the conductor. Solder them
Shell
together through the hole on the pin.

Insert the pin into the shell. Screw the clamp


nut into the shell.
Solder through
(Tighten by turning the clamp nut. Do not
the hole. tighten by turning the shell.)

How to fabricate antenna cable 8D-FB-CV

11
Downloaded from www.Manualslib.com manuals search engine
2. WIRING

12D-SFA-CV (100 m)

Outer Sheath Dimensions in millimeters.


Armor Inner Sheath Shield Remove outer sheath and armor by the
dimensions shown left.
Expose inner sheath and shield by the
80 12 dimensions shown left.

Twist shield end.

Slip on clamp nut, gasket and clamp as shown left.

Nut Gasket Clamp


Washer

1.8
Expose the insulator by 1.8 mm.

Expose the core by 4.5 mm.


4.5
Pin
Clamp Nut Slip the pin onto the conductor. Solder them
together through the hole on the pin.

Insert the pin into the shell. Screw the clamp


nut into the shell.
(Tighten by turning the clamp nut. Do not
Solder through tighten by turning the shell.)
the hole.

How to fabricate antenna cable 12D-SFA-CV

12
Downloaded from www.Manualslib.com manuals search engine
2. WIRING

2.2 Distress Alert/Received Call Unit IC-305


Use the installation material CP16-02201 to connect the distress alert IC-305.
The optional CO-SPEVV-SB-C 0.2x5P cable or JIS cable (Japan Industrial
Standards) TTYCS-4 or equivalent are available to connect with the junction box
IC-305. Select the cable clamp attached depending on the diameter of cable,
and fix the armor of cable with the clamp.
Armor

Shield
Vinyl sheath
Conductor
(Twisted pair)

2
S =1.25 mm
=1.35 mm Painting

(Sectional view)

TTYCS-4 cable, sectional view

16P0213

For CO-SPEVV-
SB-C 0.2x5P 1 2 3 4 5

Twist the shield.


For TTYCS-4 (JIS)
or equivalent
CO-SPEVV-SB-C 0.2X5P
or TTYCS-4
Distress alert
IC-305 15 mm 40 mm 10 mm
Cut unused cables.

Wiring of distress alert IC-305

13
Downloaded from www.Manualslib.com manuals search engine
2. WIRING

2.3 Alarm Unit IC-306


Maximum three alarm units can be connected to the junction box IC-315 in
parallel. To distinguish the incoming indictors, set jumper wires for the second
alarm unit as below. For connection, refer to the “2.2 Distress Alert/Received Call
Unit IC-305.”

16P0213 JP2
JP1

Alarm unit IC-306

No. 1 (default setting) No. 2 No. 3


JP1 Open Open Short
JP2 Short Open Open

14
Downloaded from www.Manualslib.com manuals search engine
2. WIRING

2.4 Junction Box IC-315


Use the junction box IC-315 to connect the distress alert/received call unit
IC-305 and other unit (max. four units) to the terminal unit.
Unfasten four screws to remove the box cover to connect cables.

For connection, use the optional 5 pair cable CO-SPEVV-SB-C 0.2x5P, JIS cable
(Japan Industrial Standards) TTYCS-4 or equivalent. When using the
CO-SPEVV-SB-C 0.2x5P cable, replace the cable clamp with the cable clamp
16-018-6008-1, supplied with IC-315.
1 Vcc

IC-305/306
2 GND
3 TD/RD-A
4 TD/RD-B
Cover 5 NC
6 TD-A(NAV) 1
7 TD-B(NAV) 2
8 RD-A(NAV)
9 RD-B(NAV)
10 GND
11 DMC OUT-H
Cable clamp 12 DMC OUT-C
13 DMC IN-H
14 DMC IN-C 3 Core 7 mm
15 DMC CTR
Terminal
board Sticker for
To terminal unit
connection of
other equipment
Procedure
1. Insert driver from direction 1 .
2. Tilt slightly toward 2 .
3. Insert cable core to 3 .

4. Pull out the driver.


Note 1: Do not insert the cable deeply
to prevent pinching the cable sheath.

Note 2: Pull the cable slightly to confirm


the tightening

Junction Box IC-315


Input/output sentences
The following sentences can be input/output with the navigator connected.
Input sentences Output sentences
GGA, GLL, VTG, WPL, RMA, RMB,
RMC, MTW, DBT, BWC, BWR, VDR, GGA, ZDA, GLL, VTG, RMC, GSV
ZDA

15
Downloaded from www.Manualslib.com manuals search engine
3. INITIAL SETTINGS
3.1 Setting the IMN (INMARSAT MOBILE NO.)
After the wiring, set your IMN (Inmarsat Mobile No.) as below.

1. Turn the power on.


2. Press the function key [F8] to show the Setup menu.
File Edit Transmit EGC Reports Logs Options Setup Position StopAlarm

Setup
1. Distress Alert Setup
2. System Setup
3. Editor Setup
4. Terminal Setup
5. EGC Setup
6. Auto Mode Setup
7. E-Mail Setup
8. Directories
9. Configuration

Setup menu
3. Press [2] key to display the System Setup menu.
Setup
System Setup
System Date & Time 01:53 02-02-25 (YY-MM-DD)
IMN
MES Operation Mode INMARSAT-C
Nav Port OFF
Active Port INT
Message Output Port INT
EGC Output Port INT
9.Network
Configuration
Setup
Command Window

System Setup menu


4. Confirm that the IMN is selected, and then press the [Enter] key.
The entering field appears.
5. Key in your IMN.
6. Press the [Enter] key.
7. Press the [Esc] key to disappear the entering field.
8. Press the [Enter] key.

To clear the IMN, press [I] [M] [N] in order while pressing the [Alt] key down at step 5.

16
Downloaded from www.Manualslib.com manuals search engine
3. INITIAL SETTINGS

3.2 Setting for External Equipment


The FELCOM 15 system had been set to accommodate to distress alert/received call unit
IC-305, up to three alarm units IC-306 and distress message controller DMC-5 at factory. If
less than three units are connected, change the setting to OFF as below.

1. Press the [F8] key to show the Setup menu.


2. Press the [2] key to show the System Setup menu.
3. Press the [↓] key to select “Command Window”, and then press [Enter] key to show the
Command Window screen.
4. Referring to the service manual for FELOM15, fill in the “Enter JOB No.:” and then press
the [Enter] key.
5. As similar to step 4, fill in the “PASSWORD:”, and then press the [Enter] key.
[Main Menu] is highlighted.
6. Press the [1] and [Enter] keys in order.
Setup
System Setup
System Date & Time 01:53 02-02-25 (YY-MM-DD)
IMN
MES Operation Mode Command Window
INMARSAT-C
[ Main
Nav Port Menu ] OFF
1. Remote
Active Port Box Setup INT
2. Internal
Message GPSPort
Output Setup INT
Enter
EGC JOB Port
Output No.: 1 INT
9.Network
Configuration
Setup
[ RemoteWindow
Command Box Setup ]
1. DMC ON
2. IC-305 ON
3. IC-306 No.1 ON
4. IC-306 No.2 ON
5. IC-306 No.3 ON
E: Exit
Enter No.:

Command Window screen

7. Press the number key for unit not connected, and then press the [Enter] key.
For example, press the [1] and [Enter] keys when the DMC-5 is not connected.

[ DMC ]
1. ON
2. OFF E: Exit
Enter No.:

Setting window for DMC-5


8. Press the [2] key, and the [Enter] key.
Instead of a numeric key, press the [E] key to return to Remote Box Setup menu.
9. Repeat steps 7 to 8 for other unit not connected.
10. Press the [Esc] key several times to close the menu.

17
Downloaded from www.Manualslib.com manuals search engine
4. INSTALLATION OF GPS BOARD
(OPTION)
This chapter provides the procedure for the installation of the GPS board (in the terminal
unit), which provides GPS position information.

Name: GPS board


Type: OP16-47
Code No.: 000-017-110

Name Type Code No. Qty Remarks


GPS board 16P0246 004-656-550 1
Pan head screw M3x8 000-163-190-10 3

Note: Use anti-static gloves to treat board.


1. Unfasten 18 screws, six spacers and three nuts to remove the terminal unit cover.
Torque Nut Rounding
side
0.7±60.02 N·m

Torque Nut, flat washer


1.37±0.1 N·m
Cover
Spacer
6 pcs.
Pan head screw
M3x8, 18 pcs.
* *
*
* ** ** *
* *
* *
* *
* * *
*
* * * *
*

* * *
*: Remove

Terminal unit, cover removed

18
Downloaded from www.Manualslib.com manuals search engine
4. INSTALLATION OF GPS BOARD (OPTION)

2. Unfasten four pan head screws (M3x8) to remove the RF cover (S).
3. Fasten three pan head screws (M3x8, supplied with the kit) to attach the GPS board to
the RF cover.
4. Attach the 7P connector from the RF cover to the JI on the GPS board.
Cable

Pan head screw


M3x8, 3 pcs.
7P connector
J1 GPS board

Pan head screw


M3x8, 4 pcs.
(marked with "#")
# #
RF cover (S)

#
#
RF cover
J1

Grommet

Removing RF Cover (S)/Fixing GPS Board


5. Pass the cable from the GPS board through the hole on the RF cover, and then connect
it to J4 on the RF CON/CPU board.
GPS board RF CON/CPU board How to treat connectors
1. Attach the connector at right angle.
Pass the cable If not, connector pins may be bent.
through this hole. 2. After connecting connector assemblies, the load
on their cables should be as below.
J4
RF cover less than 2.94N (300gf)
Pass the cable
under the RF cover. less than 9.8N (1kgf)

Fix the cable with the clamp. less than 2.94N (300gf)

Fasten the cable at the clamp next to the J4 connector.


6. Remount the RF cover (S) using four pan head screws (M3x8) unfastened at step 2.

19
Downloaded from www.Manualslib.com manuals search engine
4. INSTALLATION OF GPS BOARD (OPTION)

a
b
7. Reassemble the terminal unit as below.
a) Fasten six spacers ○a by hand tentatively.
b) Fasten eight pan head screws ○b tightly.
c) Fasten six spacers ○a by box driver tightly.
d) Fasten other screws and washers to complete. b b

Terminal unit, rear view

20
Downloaded from www.Manualslib.com manuals search engine
5. CHANGING POWER SUPPLY
SPECIFICATIONS
The AC-DC power supply PR-240 is shipped ready for connection to a 200-230 VAC ship’s
mains. If the ship’s mains is 100 VAC-115 VAC, change the tap connection and terminal
board connection as below. Attach a label supplied as accessories to the front panel
according to the ship’s mains.
Ship’s mains Tap connection Terminal board Label
200-230 VAC 2.2-1.7 A
200-230 VAC SEL 230 V Below (a)
1φ 50/60 Hz
100-115 VAC 3.2-2.6 A
100-115 VAC SEL 115 V Below (b)
1φ 50/60 Hz

Remove screw
and cover.

Cover

Front panel
(a) 200-230 VAC
Relay
1 Black Coil
2 Grey 3
J4 2
3 1

1 SEL
Terminal board 2 115V
3 Heat sink
4 SEL
(b) 100-115 VAC 5 230V
6
1 Black 7
8
2 Grey
3
Tap connection
(Pull out to disconnect.)

Front panel
Attach appropriate label.

AC FAIL:Connect to Alarm system.


Output Setting: Normal Close Set plug to 2 & 3 pins of J4 (Factory setting)
Normal Open Set plug to 1 & 2 pins of J4

AC Power Switch
(When connecting DC input, note that the DC power is supplied
even though this switch is turned off.)

Note: The DC output load must be less than 8A.

21
Downloaded from www.Manualslib.com manuals search engine
IC-215-J*/IC-215-E* 16AK-X-9851 -6 1/1
PACKING LIST
NAME OUTLINE DESCRIPTION/CODE № Q'TY NAME OUTLINE DESCRIPTION/CODE № Q'TY
機器引渡し前の注意 C52-00201-* ワ/エイ
ユニット UNIT 1
BEFORE DELIVERING TO OWNER
ターミナルユニット 000-809-353-1*
IC-215* 1
TERMINAL UNIT 取扱説明書 OM*-56350-*
**
1
000-043-432-00 OPERATOR'S MANUAL
000-809-348-1* **
予備品 SPARE PARTS SP16-01301
取扱説明書 OM*-56351-* 1
予備品 SP16-01301 (IC-215用) OPERATOR'S MANUAL
1 **
SPARE PARTS 000-150-358-1*
004-439-370-00 装備要領書 IM*-56350-* 1
INSTALLATION MANUAL

Downloaded from www.Manualslib.com manuals search engine


付属品 ACCESSORIES FP16-00600 **
000-809-350-1*
フロッピーディスク組品 FP16-00601
遭難通信要領 TIC-56350-* ワ/エイ
1 1
FLOPPY DISK DISTRESS COMMUNICATION
004-439-400-00 000-809-352-1*
ミニキーボード G84-4100PPAUS 1
KEYBOARD
000-172-018-10

工事材料 INSTALLATION MATERIALS CP16-02301


工事材料 CP16-02301 1
INSTALLATION MATERIALS
004-439-380-00

工事材料 INSTALLATION MATERIALS CP16-02302


工事材料 CP16-02302 1
INSTALLATION MATERIALS
004-439-390-00

図書 DOCUMENT
アプリケーションフォ-ム J5-950010-* ワ/エイ 1
REGISTRATION FOR SERVICE
ACTIVATION 000-807-330-1*
ヒューズ変更のお願い C52-00206-* 1
NOTICE FOR FUSE REPLACEMENT
000-147-004-1*

1.コ-ド番号末尾の[**]は、選択品の代表型式/コードを表します。
CODE NUMBER ENDING WITH "**" INDICATES THE CODE NUMBER OF REPRESENTATIVE MATERIAL
A-1

型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりません。
TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) PLACE OF THE UPPER PRODUCT. QUALITY IS THE SAME.

C5635-Z01-D
#-:   #-:  
㧼㧭㧯㧷㧵㧺㧳‫ޓ‬㧸㧵㧿㨀 㧼㧭㧯㧷㧵㧺㧳‫ޓ‬㧸㧵㧿㨀
A-2 A-3
+% +%
0#/' 176.+0' &'5%4+26+10%1&'ͳ 3 6; 0#/' 176.+0' &'5%4+26+10%1&'ͳ 3 6;
࡙࠾࠶࠻ 70+6 ࡙࠾࠶࠻ 70+6
ㆣ㔍⼊ႎེ ⌕ାᜰ␜ེ
+%  +% 
&+564'55#.'4670+6 #.#4/70+6
 
Ꮏ੐᧚ᢱ +056#..#6+10/#6'4+#.5 %2 Ꮏ੐᧚ᢱ +056#..#6+10/#6'4+#.5 %2
㩎㩡㩇㩊㨹㩕㩩㩧㩒㩆㩨㩆㨷 㩎㩡㩇㩊㨹㩕㩩㩧㩒㩆㩨㩆㨷
:575  :575 
5'.(6#22+0)5%4'9 5'.(6#22+0)5%4'9
 
࿶⌕┵ሶ ࿶⌕┵ሶ
(8
.(  (8
.( 
%4+/210.7) %4+/210.7)

Downloaded from www.Manualslib.com manuals search engine


 
࿶⌕┵ሶ ࿶⌕┵ሶ
(8  (8 
%4+/210.7) %4+/210.7)
 
࿑ᦠ &1%7/'06
+%ᒁ߈ᷰߒ೨ߩᵈᗧ
% 
$'(14'&'.+8'4+0)61190'4




㪈㪅㩿㪁㪈䋩䈱䋪䋪䋪䋪䈲䇮᦭䉍䊶ή䈚䈱઀᭽䈏᦭䉍䉁䈜䇯
㪘㪭㪘㪠㪣㪘㪙㪣㪜㩷㪮㪠㪫㪟㩷㪦㪩㩷㪮㪠㪫㪟㪦㪬㪫㩷㪁㪁㪁㪁㪁㩷㪬㪥㪠㪫㪅

ဳᑼ㪆䍘䍎䍢䍼⇟ภ䈏䋲Ბ䈱႐ว䇮ਅᲑ䉋䉍਄Ბ䈮ઍ䉒䉎ㆊᷰᦼຠ䈪䈅䉍䇮䈬䈤䉌䈎䈏౉䈦䈩䈇䉁䈜䇯䇭䈭䈍䇮ຠ⾰䈲ᄌ䉒䉍䉁䈞䉖䇯 ဳᑼ㪆䍘䍎䍢䍼⇟ภ䈏䋲Ბ䈱႐ว䇮ਅᲑ䉋䉍਄Ბ䈮ઍ䉒䉎ㆊᷰᦼຠ䈪䈅䉍䇮䈬䈤䉌䈎䈏౉䈦䈩䈇䉁䈜䇯䇭䈭䈍䇮ຠ⾰䈲ᄌ䉒䉍䉁䈞䉖䇯
㪫㪮㪦㩷㪫㪰㪧㪜㪪㩷㪘㪥㪛㩷㪚㪦㪛㪜㪪㩷㪤㪘㪰㩷㪙㪜㩷㪣㪠㪪㪫㪜㪛㩷㪝㪦㪩㩷㪘㪥㩷㪠㪫㪜㪤㪅㩷㩷㪫㪟㪜㩷㪣㪦㪮㪜㪩㩷㪧㪩㪦㪛㪬㪚㪫㩷㪤㪘㪰㩷㪙㪜㩷㪪㪟㪠㪧㪧㪜㪛㩷㪠㪥㩷㪧㪣㪘㪚㪜㩷㪦㪝㩷㪫㪟㪜㩷㪬㪧㪧㪜㪩㩷 㪫㪮㪦㩷㪫㪰㪧㪜㪪㩷㪘㪥㪛㩷㪚㪦㪛㪜㪪㩷㪤㪘㪰㩷㪙㪜㩷㪣㪠㪪㪫㪜㪛㩷㪝㪦㪩㩷㪘㪥㩷㪠㪫㪜㪤㪅㩷㩷㪫㪟㪜㩷㪣㪦㪮㪜㪩㩷㪧㪩㪦㪛㪬㪚㪫㩷㪤㪘㪰㩷㪙㪜㩷㪪㪟㪠㪧㪧㪜㪛㩷㪠㪥㩷㪧㪣㪘㪚㪜㩷㪦㪝㩷㪫㪟㪜㩷㪬㪧㪧㪜㪩㩷
㪧㪩㪦㪛㪬㪚㪫㪅㩷㪨㪬㪘㪣㪠㪫㪰㩷㪠㪪㩷㪫㪟㪜㩷㪪㪘㪤㪜㪅 㪧㪩㪦㪛㪬㪚㪫㪅㩷㪨㪬㪘㪣㪠㪫㪰㩷㪠㪪㩷㪫㪟㪜㩷㪪㪘㪤㪜㪅

䋨⇛࿑䈱ኸᴺ䈲䇮ෳ⠨୯䈪䈜䇯㩷㩷㪛㪠㪤㪜㪥㪪㪠㪦㪥㪪㩷㪠㪥㩷㪛㪩㪘㪮㪠㪥㪞㩷㪝㪦㪩㩷㪩㪜㪝㪜㪩㪜㪥㪚㪜㩷㪦㪥㪣㪰㪅䋩 䋨⇛࿑䈱ኸᴺ䈲䇮ෳ⠨୯䈪䈜䇯㩷㩷㪛㪠㪤㪜㪥㪪㪠㪦㪥㪪㩷㪠㪥㩷㪛㪩㪘㪮㪠㪥㪞㩷㪝㪦㪩㩷㪩㪜㪝㪜㪩㪜㪥㪚㪜㩷㪦㪥㪣㪰㪅䋩
%<% %<%
A-4 A-5

%1&'01 #-:  %1&'01  #-: 


6;2'  6;2' %2 

Ꮏ੐᧚ᢱ⴫ Ꮏ੐᧚ᢱ⴫
+%
+056#..#6+10/#6'4+#.5 +056#..#6+10/#6'4+#.5
⇟ภ ฬ‫ޓޓ‬⒓ ⇛‫ޓޓ‬࿑ ဳฬ㧛ⷙᩰ ᢙ㊂ ↪ㅜ㧛஻⠨ ⇟ภ ฬ‫ޓޓ‬⒓ ⇛‫ޓޓ‬࿑ ဳฬ㧛ⷙᩰ ᢙ㊂ ↪ㅜ㧛஻⠨
01 0#/' 176.+0' &'5%4+26+105 3 6; 4'/#4-5 01 0#/' 176.+0' &'5%4+26+105 3 6; 4'/#4-5
㩃㨺㩖㩨㩣⚵ຠ ㆬᛯ‫ޓޓޓޓޓޓޓ‬ 㨼㩡㨹㩂㩇㩇㩢㨺㩖㩨5%/
‫ޓ‬61$'5'.'%6'&
 &5(#%8 /   㩂㩥‫ ޓ‬// 
%#$.'#55; +057.#6+105.''8'
%1&'01 %1&'01
 
㨻㩧㩍㩏㩃㨺㩖㩨㩣⚵ຠ ㆬᛯ‫ޓޓޓޓޓޓޓ‬ 㩃㨺㩖㩨㩣଻⼔᧚
‫ޓ‬61$'5'.'%6'&
 &($%8 /   41*5 
%#$.'#55; %#$.'2416'%6+10
%1&'01 /#6'4+#. %1&'01

Downloaded from www.Manualslib.com manuals search engine


 
㩃㨺㩖㩨㩣⚵ຠ ㆬᛯ‫ޓޓޓޓޓޓޓ‬ 㩄㩧㩗㩨㨹㩂㩇
‫ޓ‬61$'5'.'%6'&
 62($#9&($/   %8$ 
%#$.'#55; %#$.'6+'
%1&'01 %1&'01
 
หゲ㩃㨺㩖㩨㩣 ㆬᛯ‫ޓޓޓޓޓޓޓ‬ 㩖㩨㩋㩣㩄㩨㩛㩍㨺㩖㩩
‫ޓ‬61$'5'.'%6'&
 &($%802 /   01 
#4/174'&%1#:+#.%#$.' 5'.($10&+0)6#2'
%1&'01 %1&'01
 
㩃㨺㩖㩨㩣⚵ຠ 49

 49 
%#$.'#55;
%1&'01 

㩃㩚㩆㨺㩣
 59㨻㩣㩚㩋㨷㨺㩖㩨) 
5+.+%1047$$'4
%1&'01


ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐ว‫ޔ‬ਅᲑࠃࠅ਄Ბߦઍࠊࠆㆊᷰᦼຠߢ޽ࠅ‫ޔ߅ߥޓޕߔ߹޿ߡߞ౉߇߆ࠄߜߤޔ‬ຠ⾰ߪᄌࠊࠅ߹ߖࠎ‫ޕ‬ ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐ว‫ޔ‬ਅᲑࠃࠅ਄Ბߦઍࠊࠆㆊᷰᦼຠߢ޽ࠅ‫ޔ߅ߥޓޕߔ߹޿ߡߞ౉߇߆ࠄߜߤޔ‬ຠ⾰ߪᄌࠊࠅ߹ߖࠎ‫ޕ‬

6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4241&7%6 6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4241&7%6
37#.+6;+56*'5#/' 37#.+6;+56*'5#/'
㧔⇛࿑ߩኸᴺߪ‫ޔ‬ෳ⠨୯ߢߔ‫&ޓޕ‬+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕 㧔⇛࿑ߩኸᴺߪ‫ޔ‬ෳ⠨୯ߢߔ‫&ޓޕ‬+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕
㧲㨁㧾㨁㧺㧻‫ޓ‬㧱㧸㧱㧯㨀㧾㧵㧯‫ޓ‬㧯㧻‫ޓ‬㧚㧘㧸㨀㧰 㧲㨁㧾㨁㧺㧻‫ޓ‬㧱㧸㧱㧯㨀㧾㧵㧯‫ޓ‬㧯㧻‫ޓ‬㧚㧘㧸㨀㧰
%/' %/-
A-6 A-7

%1&'01  #-:  %1&'01  #-: 


6;2' %2  6;2' %2 

Ꮏ੐᧚ᢱ⴫ Ꮏ੐᧚ᢱ⴫
+056#..#6+10/#6'4+#.5 +056#..#6+10/#6'4+#.5
⇟ภ ฬ‫ޓޓ‬⒓ ⇛‫ޓޓ‬࿑ ဳฬ㧛ⷙᩰ ᢙ㊂ ↪ㅜ㧛஻⠨ ⇟ภ ฬ‫ޓޓ‬⒓ ⇛‫ޓޓ‬࿑ ဳฬ㧛ⷙᩰ ᢙ㊂ ↪ㅜ㧛஻⠨
01 0#/' 176.+0' &'5%4+26+105 3 6; 4'/#4-5 01 0#/' 176.+0' &'5%4+26+105 3 6; 4'/#4-5
㨼㩡㨹㩂㩇㩇㩢㨺㩖㩨5%/ 㨼㩡㨹㩂㩇㩇㩢㨺㩖㩨5%/
 㩂㩥‫ ޓ‬//   㩂㩥‫ ޓ‬// 
+057.#6+105.''8' +057.#6+105.''8'
%1&'01 %1&'01
 
㩃㨺㩖㩨㩣଻⼔᧚ 㩃㨺㩖㩨㩣଻⼔᧚
 41*5   41*5 
%#$.'2416'%6+10 %#$.'2416'%6+10
/#6'4+#. %1&'01 /#6'4+#. %1&'01

Downloaded from www.Manualslib.com manuals search engine


 
㩄㩧㩗㩨㨹㩂㩇 㩄㩧㩗㩨㨹㩂㩇
 %8$   %8$ 
%#$.'6+' %#$.'6+'
%1&'01 %1&'01
 
㩖㩨㩋㩣㩄㩨㩛㩍㨺㩖㩩 㩖㩨㩋㩣㩄㩨㩛㩍㨺㩖㩩
 01   01 
5'.($10&+0)6#2' 5'.($10&+0)6#2'
%1&'01 %1&'01
 
㩄㩒㩂㩊
0 㩄㩒㩂㩊
0
 02&($%(   052&5(#%( 
%1#:+#.%100'%614 0 %100'%614
6;2' %1&'01 %1&'01
 
㩃㨺㩖㩨㩣⚵ຠ 49 㩃㨺㩖㩨㩣⚵ຠ 49

 49   49 
%#$.'#55; %#$.'#55;
%1&'01  %1&'01 
 
㩃㩚㩆㨺㩣 㩃㩚㩆㨺㩣
 59㨻㩣㩚㩋㨷㨺㩖㩨)   59㨻㩣㩚㩋㨷㨺㩖㩨) 
5+.+%1047$$'4 5+.+%1047$$'4
%1&'01 %1&'01
 
㩄㩒㩂㩊
60%0 㩄㩒㩂㩊
60%0
 60%20,   60%20, 
%1#:+#.%100'%614 %1#:+#.%100'%614
#&#2614 %1&'01 #&#2614 %1&'01
 
㩃㨺㩖㩨㩣⚵ຠ 㩃㨺㩖㩨㩣⚵ຠ
 62#($10,($#&($   62#($10,($#&($ 
%#$.'#55'/$.; %#$.'#55'/$.;
%1&'01 %1&'01
 

ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐ว‫ޔ‬ਅᲑࠃࠅ਄Ბߦઍࠊࠆㆊᷰᦼຠߢ޽ࠅ‫ޔ߅ߥޓޕߔ߹޿ߡߞ౉߇߆ࠄߜߤޔ‬ຠ⾰ߪᄌࠊࠅ߹ߖࠎ‫ޕ‬ ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐ว‫ޔ‬ਅᲑࠃࠅ਄Ბߦઍࠊࠆㆊᷰᦼຠߢ޽ࠅ‫ޔ߅ߥޓޕߔ߹޿ߡߞ౉߇߆ࠄߜߤޔ‬ຠ⾰ߪᄌࠊࠅ߹ߖࠎ‫ޕ‬

6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4241&7%6 6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4241&7%6
37#.+6;+56*'5#/' 37#.+6;+56*'5#/'
㧔⇛࿑ߩኸᴺߪ‫ޔ‬ෳ⠨୯ߢߔ‫&ޓޕ‬+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕 㧔⇛࿑ߩኸᴺߪ‫ޔ‬ෳ⠨୯ߢߔ‫&ޓޕ‬+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕

㧲㨁㧾㨁㧺㧻‫ޓ‬㧱㧸㧱㧯㨀㧾㧵㧯‫ޓ‬㧯㧻‫ޓ‬㧚㧘㧸㨀㧰 㧲㨁㧾㨁㧺㧻‫ޓ‬㧱㧸㧱㧯㨀㧾㧵㧯‫ޓ‬㧯㧻‫ޓ‬㧚㧘㧸㨀㧰
%/. %/.
A-8 A-9

%1&'01  #-:  %1&'01  #%: 


6;2' %2  6;2' %2 

Ꮏ੐᧚ᢱ⴫ Ꮏ੐᧚ᢱ⴫
+%
+056#..#6+10/#6'4+#.5 +056#..#6+10/#6'4+#.5
⇟ภ ฬ‫ޓޓ‬⒓ ⇛‫ޓޓ‬࿑ ဳฬ㧛ⷙᩰ ᢙ㊂ ↪ㅜ㧛஻⠨ ⇟ภ ฬ‫ޓޓ‬⒓ ⇛‫ޓޓ‬࿑ ဳฬ㧛ⷙᩰ ᢙ㊂ ↪ㅜ㧛஻⠨
01 0#/' 176.+0' &'5%4+26+105 3 6; 4'/#4-5 01 0#/' 176.+0' &'5%4+26+105 3 6; 4'/#4-5
㨼㩡㨹㩂㩇㩇㩢㨺㩖㩨5%/ 㩔㩢㩙㨺㩂
+0/#4
 㩂㩥‫ ޓ‬//   41*5 
+057.#6+105.''8' .#$'.
+0/#4
%1&'01 %1&'
 01 
㩃㨺㩖㩨㩣଻⼔᧚ 㩔㩢㩙㨺㩂 %1/2#555#('
&+56#0%'
 41*5   41*5 
%#$.'2416'%6+10 56+%-'4
/#6'4+#. %1&'01 %1&'

Downloaded from www.Manualslib.com manuals search engine


 01 
㩄㩧㩗㩨㨹㩂㩇 㩃㨺㩖㩨㩣⚵ຠ
 %8$   5 
%#$.'6+' 219'4%#$.'#55;
%1&'01 %1&'
 01 
㩖㩨㩋㩣㩄㩨㩛㩍㨺㩖㩩 㩃㨺㩖㩨㩣⚵ຠ 㩊㨺㩚㩏㩣㩟㩐㨹㩎↪‫(ޓ‬14
6'4/+0#.70+6
 01   (','$%2. 
5'.($10&+0)6#2' %#$.'#55'/$.;
%1&'01 %1&'
 01 
㩄㩒㩂㩊
0 㩎㩡㩇㩊㨹㩕㩩㩧㩒㩆㩨‫ޓ‬㩆㨷
 02&($%(   :575 
%100'%614 5'.(6#22+0)5%4'9
%1&'01 %1&'
 01 
㩃㨺㩖㩨㩣⚵ຠ 49 㩖㩩㩢㩧㩊ขઃ᧼
 ⚵ຠ
 49   %2 
%#$.'#55; 24+06'4(+:674'
%1&'01  %1&'
 01 
㩃㩚㩆㨺㩣 㩖㩩㩢㩧㩊ขઃ᧼
 ⚵ຠ
 59㨻㩣㩚㩋㨷㨺㩖㩨)   %2 
5+.+%1047$$'4 24+06'4(+:674'
%1&'01 %1&'
 01 
㩄㩒㩂㩊
60%0
 60%20, 
%1#:+#.%100'%614
#&#2614 %1&'01

㩃㨺㩖㩨㩣⚵ຠ
 62#($10,($#&($ 
%#$.'#55'/$.;
%1&'01


ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐ว‫ޔ‬ਅᲑࠃࠅ਄Ბߦઍࠊࠆㆊᷰᦼຠߢ޽ࠅ‫ޔ߅ߥޓޕߔ߹޿ߡߞ౉߇߆ࠄߜߤޔ‬ຠ⾰ߪᄌࠊࠅ߹ߖࠎ‫ޕ‬ ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐ว‫ޔ‬ਅᲑࠃࠅ਄Ბߦઍࠊࠆㆊᷰᦼຠߢ޽ࠅ‫ޔ߅ߥޓޕߔ߹޿ߡߞ౉߇߆ࠄߜߤޔ‬ຠ⾰ߪᄌࠊࠅ߹ߖࠎ
‫ޕ‬
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4241&7%6 6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4
37#.+6;+56*'5#/' 241&7%637#.+6;+56*'5#/'
㧔⇛࿑ߩኸᴺߪ‫ޔ‬ෳ⠨୯ߢߔ‫&ޓޕ‬+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕 㧔⇛࿑ߩኸᴺߪ‫ޔ‬ෳ⠨୯ߢߔ‫&ޓޕ‬+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕
㧲㨁㧾㨁㧺㧻‫ޓ‬㧱㧸㧱㧯㨀㧾㧵㧯‫ޓ‬㧯㧻‫ޓ‬㧚㧘㧸㨀㧰 㧲㨁㧾㨁㧺㧻‫ޓ‬㧱㧸㧱㧯㨀㧾㧵㧯‫ޓ‬㧯㧻‫ޓ‬㧚㧘㧸㨀㧰
%/$ %/)
##:  
㧼㧭㧯㧷㧵㧺㧳‫ޓ‬㧸㧵㧿㨀
A-10 A-11
24%'/5#
%1&'01  #-: 
6;2' 
0#/' 176.+0' &'5%4+26+10%1&'ͳ 3 6;
%2
࡙࠾࠶࠻ 70+6
Ꮏ੐᧚ᢱ⴫ #%&%㔚Ḯ
24 
+056#..#6+10/#6'4+#.5 219'45722.;70+6

⇟ภ ฬ‫ޓޓ‬⒓ ⇛‫ޓޓ‬࿑ ဳฬ㧛ⷙᩰ ᢙ㊂ ↪ㅜ㧛஻⠨
176.+0' 3 6; Ꮏ੐᧚ᢱ +056#..#6+10/#6'4+#.5
01 0#/' &'5%4+26+105 4'/#4-5
41*5 Ꮏ੐᧚ᢱ
㩃㨺㩖㩨㩣᛼߃

 %2 

%#$.'%.#/2  +056#..#6+10/#6'4+#.5
%1&' 
01  
㩎㩡㩇㩊㨹㩕㩩㩧㩒㩆㩨㩆㨷
 :575
5'.(6#22+0)5%4'9 
%1&'

Downloaded from www.Manualslib.com manuals search engine


01 

䍘㪄䍢䍼⇟ภᧃየ䈱㪲㪁㪁㪴䈲䇮ㆬᛯຠ䈱ઍ⴫䍘䍎䍢䍼䉕⴫䈚䉁䈜䇯
㪚㪦㪛㪜㩷㪥㪬㪤㪙㪜㪩㩷㪜㪥㪛㪠㪥㪞㩷㪮㪠㪫㪟㩷㩹㪁㪁㩹㩷㪠㪥㪛㪠㪚㪘㪫㪜㪪㩷㪫㪟㪜㩷㪚㪦㪛㪜㩷㪥㪬㪤㪙㪜㪩㩷㪦㪝㩷㪩㪜㪧㪩㪜㪪㪜㪥㪫㪘㪫㪠㪭㪜㩷㪤㪘㪫㪜㪩㪠㪘㪣㪅

ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐ว‫ޔ‬ਅᲑࠃࠅ਄Ბߦઍࠊࠆㆊᷰᦼຠߢ޽ࠅ‫ޔ߅ߥޓޕߔ߹޿ߡߞ౉߇߆ࠄߜߤޔ‬ຠ⾰ߪᄌࠊࠅ߹ߖ
ࠎ‫ޕ‬
ဳᑼ㪆䍘䍎䍢䍼⇟ภ䈏䋲Ბ䈱႐ว䇮ਅᲑ䉋䉍਄Ბ䈮ઍ䉒䉎ㆊᷰᦼຠ䈪䈅䉍䇮䈬䈤䉌䈎䈏౉䈦䈩䈇䉁䈜䇯䇭䈭䈍䇮ຠ⾰䈲ᄌ䉒䉍䉁䈞䉖䇯
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4
241&7%637#.+6;+56*'5#/' 㪫㪮㪦㩷㪫㪰㪧㪜㪪㩷㪘㪥㪛㩷㪚㪦㪛㪜㪪㩷㪤㪘㪰㩷㪙㪜㩷㪣㪠㪪㪫㪜㪛㩷㪝㪦㪩㩷㪘㪥㩷㪠㪫㪜㪤㪅㩷㩷㪫㪟㪜㩷㪣㪦㪮㪜㪩㩷㪧㪩㪦㪛㪬㪚㪫㩷㪤㪘㪰㩷㪙㪜㩷㪪㪟㪠㪧㪧㪜㪛㩷㪠㪥㩷㪧㪣㪘㪚㪜㩷㪦㪝㩷㪫㪟㪜㩷㪬㪧㪧㪜㪩㩷
㧔⇛࿑ߩኸᴺߪ‫ޔ‬ෳ⠨୯ߢߔ‫&ޓޕ‬+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕 㪧㪩㪦㪛㪬㪚㪫㪅㩷㪨㪬㪘㪣㪠㪫㪰㩷㪠㪪㩷㪫㪟㪜㩷㪪㪘㪤㪜㪅

㧲㨁㧾㨁㧺㧻‫ޓ‬㧱㧸㧱㧯㨀㧾㧵㧯‫ޓ‬㧯㧻‫ޓ‬㧚㧘㧸㨀㧰 䋨⇛࿑䈱ኸᴺ䈲䇮ෳ⠨୯䈪䈜䇯㩷㩷㪛㪠㪤㪜㪥㪪㪠㪦㪥㪪㩷㪠㪥㩷㪛㪩㪘㪮㪠㪥㪞㩷㪝㪦㪩㩷㪩㪜㪝㪜㪩㪜㪥㪚㪜㩷㪦㪥㪣㪰㪅䋩
%/& %<,
A-12 A-13

%1&'01  #-:  %1&'01  #-: 


6;2' 12  6;2' %2 

ᡷㅧ㩁㨹㩎 Ꮏ੐᧚ᢱ⴫
/1&+(+%#6+10-+6 +%
+056#..#6+10/#6'4+#.5
⇟ภ ฬ‫ޓޓ‬⒓ ⇛‫ޓޓ‬࿑ ဳฬ㧛ⷙᩰ ᢙ㊂ ↪ㅜ㧛஻⠨ ⇟ภ ฬ‫ޓޓ‬⒓ ⇛‫ޓޓ‬࿑ ဳฬ㧛ⷙᩰ ᢙ㊂ ↪ㅜ㧛஻⠨
01 0#/' 176.+0' &'5%4+26+105 3 6; 4'/#4-5 01 0#/' 176.+0' &'5%4+26+105 3 6; 4'/#4-5
ਛ࿖41*5㩙㨺㩂 㩕㨷㨺㩇㩨㩔㩢㩙㨺㩂
    41*5
%*+0#41*55'#. (75'.#$'. 
%1&'01 %1&'
 01 
㩔㩢㩙㨺㩂
#.% ‫ޓ‬41*5 㨻㨺㩇᧼ 41*5

    
.#$'. %122'4564#2 
%1&'01  %1&' 

Downloaded from www.Manualslib.com manuals search engine


 01 
ဳᑼ㌏᧼
#.% 㩎㩡㩇㩊㨹㩕㩩㩧㩒㩆㩨‫ޓ‬㩆㨷
    :575
0#/'2.#6'
#.% 5'.(6#22+0)5%4'9 
%1&'01 %1&'
 01 
(&41/ 㩕㨷㨺㩇㩨
    ()$18#2$(
(.122;&+5-41/ (75').#5567$'6;2' 
%1&'01 %1&'
 01 
㩃㨺㩖㩨㩣⚵ຠ/,
 /,#52(<%
%#$.'#55; 
%1&'
01 

ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐ว‫ޔ‬ਅᲑࠃࠅ਄Ბߦઍࠊࠆㆊᷰᦼຠߢ޽ࠅ‫ޔ߅ߥޓޕߔ߹޿ߡߞ౉߇߆ࠄߜߤޔ‬ຠ⾰ߪᄌࠊࠅ߹ߖ
ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐ว‫ޔ‬ਅᲑࠃࠅ਄Ბߦઍࠊࠆㆊᷰᦼຠߢ޽ࠅ‫ޔ߅ߥޓޕߔ߹޿ߡߞ౉߇߆ࠄߜߤޔ‬ຠ⾰ߪᄌࠊࠅ߹ߖࠎ‫ޕ‬ ࠎ‫ޕ‬
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4241&7%6 241&7%637#.+6;+56*'5#/'
37#.+6;+56*'5#/'
㧔⇛࿑ߩኸᴺߪ‫ޔ‬ෳ⠨୯ߢߔ‫&ޓޕ‬+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕 㧔⇛࿑ߩኸᴺߪ‫ޔ‬ෳ⠨୯ߢߔ‫&ޓޕ‬+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕
㧲㨁㧾㨁㧺㧻‫ޓ‬㧱㧸㧱㧯㨀㧾㧵㧯‫ޓ‬㧯㧻‫ޓ‬㧚㧘㧸㨀㧰 㧲㨁㧾㨁㧺㧻‫ޓ‬㧱㧸㧱㧯㨀㧾㧵㧯‫ޓ‬㧯㧻‫ޓ‬㧚㧘㧸㨀㧰
%/& %/'
A-14 A-15
%1&'01  #-:  
%1&'01  #-: 
6;2' 52 $1:012
6;2' %2 
5'652'4
5*+201 52#4'2#465.+56(14 75' 8'55'.
Ꮏ੐᧚ᢱ⴫
+056#..#6+10/#6'4+#.5
⇟ภ ฬ‫ޓޓ‬⒓ ⇛‫ޓޓ‬࿑ ဳฬ㧛ⷙᩰ ᢙ㊂ ↪ㅜ㧛஻⠨
01 0#/' 176.+0' &'5%4+26+105 3 6; 4'/#4-5 &9)01 37#06+6; 4'/#4-5%1&'01
㩖㨱㩇㩏㨺
 +6'/ 0#/'1( 14 914-+0)
01 2#46 176.+0'
41*5 6;2'01 2'4 2'4 52#4'
 
*11-.112(#56'0'4 5'6 8'5
%1&'01
 㩕㨷㨺㩇㩨
㩖㨱㩇㩏㨺
  (75' 
41*5 ()$18
 
*11-.112(#56'0'4 #2$(

%1&'01

Downloaded from www.Manualslib.com manuals search engine


 㩕㨷㨺㩇㩨

㩔㩢㩙㨺㩂  (75' 
()$18#
   2$(
.#$'. 
%1&'01


ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐ว‫ޔ‬ਅᲑࠃࠅ਄Ბߦઍࠊࠆㆊᷰᦼຠߢ޽ࠅ‫ޔ߅ߥޓޕߔ߹޿ߡߞ౉߇߆ࠄߜߤޔ‬ຠ⾰ߪᄌࠊࠅ߹ߖࠎ‫ޕ‬ 
/(4 50#/' (74701'.'%64+%%1.6& &9)01 %2%
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4241&7%6
37#.+6;+56*'5#/' 㧔⇛࿑ߩኸᴺߪ‫ޔ‬ෳ⠨୯ߢߔ‫&ޓޕ‬+/'05+105+0&4#9+0)‫(ޓ‬144'('4'0%'10.;㧕
㧔⇛࿑ߩኸᴺߪ‫ޔ‬ෳ⠨୯ߢߔ‫&ޓޕ‬+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕 ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐ว‫ޔ‬ਅᲑࠃࠅ਄Ბߦઍࠊࠆㆊᷰᦼຠߢ޽ࠅ‫ޔ߅ߥޓޕߔ߹޿ߡߞ౉߇߆ࠄߜߤޔ‬ຠ
⾰ߪᄌࠊࠅ߹ߖࠎ‫ޕ‬
㧲㨁㧾㨁㧺㧻‫ޓ‬㧱㧸㧱㧯㨀㧾㧵㧯‫ޓ‬㧯㧻‫ޓ‬㧚㧘㧸㨀㧰
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(
%/( 6*'722'4241&7%637#.+6;+56*'5#/'
Downloaded from www.Manualslib.com manuals search engine
18/Jun/09 R.Esumi

Downloaded from www.Manualslib.com manuals search engine


18/Jun/09 R.Esumi

Downloaded from www.Manualslib.com manuals search engine


D-4

8/Jul/09 R.Esumi

Downloaded from www.Manualslib.com manuals search engine


Downloaded from www.Manualslib.com manuals search engine
Downloaded from www.Manualslib.com manuals search engine
Downloaded from www.Manualslib.com manuals search engine
Downloaded from www.Manualslib.com manuals search engine
Downloaded from www.Manualslib.com manuals search engine
26/Oct/09 R.Esumi

Downloaded from www.Manualslib.com manuals search engine


Downloaded from www.Manualslib.com manuals search engine
Oct.15'07 R.Esumi

Downloaded from www.Manualslib.com manuals search engine


Downloaded from www.Manualslib.com manuals search engine
Downloaded from www.Manualslib.com manuals search engine
西 山義浩
13/Jan/2012 Y.NISHIYAMA

Downloaded from www.Manualslib.com manuals search engine


1 2 3 4 5 6

アンテナユニット
ANTENNA UNIT
IC-115
アラームユニットIC-306
ケーブル/コネクタは選択 ALARM UNIT
RW-4747 SELECT CABLE & CONNECTOR 16P0213B
TNCP-NJ

0.3m
TPA5FB0.4NJ5 12D-SFA-CV,100m,φ20: N-P-12DSFA ターミナルユニット 1 VCC
FBA-5DFB,0.4m 8D-FB-CV,50m,φ14.3: N-P-8DFB TERMINAL UNIT P
2 GND
5D-FB-CV,30m,φ10.7: N-P-5DFB IC-215 3 TD/RD-A
A P
4 TD/RD-B
*7 ANT DGPS *1 5 FG
TP5FBAW-5DFBB,30m,φ7.7 BNC PLUG COAX. CABLE(50Ω) DGPSデコーダー
DGPS DECODER
遭難警報器 IC-305 IC-350を接続するとき(IC-305との共用不可)
2B02 16P0208A DISTRESS ALERT/
*3 接続箱 RECEIVED CALL UNIT CONNECTION FOR IC-350 (DO NOT USE W/ IC-305)
Dsub15P JUNCTION BOX
KEYBOARD JUNCTION IC-315 *1 16P0213A
キーボード 1.6m 2m TTYCS-4 IC-315 *1
1 KDAT Vcc(ALM) 1 1 1 VCC 選択 INMARSAT No.1/2
KEYBOARD P
SELECT TTYCS-1
2 NC GND 2 2 2 GND 3 1 TR-A
2 TR-B アラームユニット
P
3 GND TD/RD-A 3 3 3 TD/RD-A 4
4 +5V TD/RD-B 4 4
P
4 TD/RD-B 3 FG ALARM UNIT
5 KCLK NC 5 5 5 FG IC-350 *2
6 NC TD-A 6 6
TD-B 7 7 TTYCS-1(*1) OR
CO-0.2x2P(*2) 航法装置 保安警報発呼器 保安警報発呼器 保安警報発呼器
船内LAN (HUB) RJ-45 LAN RD-A 8 8 NAV EQUIPMENT
STP CABLE(CAT5) *1 1 9 9 SSAS ALERT UNIT SSAS ALERT UNIT SSAS ALERT UNIT
パソコンなど PC: CROSS CABLE P
E_TD_P RD-B
IC-307 (No.1) *2 *6 IC-307 (No.2) IC-307 (No.3)
2 10 10 TTYCS-4(*1) OR
LAN(HUB) OR PC, ETC. HUB: STRAIGHT CABLE E_TD-N GND
CO-0.2x5P(*2) *2 *6 *2 *6
3 E_RD_P DMC_OUT-H 11 11 1 SSAS_OUT-H 1 1
4 12 12 2 2 2
B P
5
NC
NC
DMC_OUT-C
DMC_CHECK 13 13
P
3
NC
SSAS_CHECK
P
3
P
3
P P P
6 E_RD_N DMC_IN-C 14 14 4 SSAS_IN-C 4 4
7 NC DMC_CTRL 15 15 5 SSAS_CTRL 5 5
8 NC 6 GND 6 6

17JE-23090 *2 17JE-13090 最大3台まで接続可能。


*3 DTE -02(D8C) 17JE-573-10,5m,φ8 -02(D8C) MAX.3 SETS AVAILABLE.
*3 17JE-23250 パソコン
プリンタ 57-3036 PRINTER CO-0.2x5P,MAX.15m TTYCS-4(*1) OR 合計 :最大200m
RH12BPG-3S 24VDC -02(D8C) 1 1 NC PC
VCTF-0.75x3C,5m,φ7 アカ RED 1 +24V PRINTER 1 1 2 2 CO-0.2x5P(*2) TOTAL: UP TO 200m
24 VDC RXD RXD
(16S0084) クロ BLK 2 0V PP-510 3 3
TXD TXD
16S0184,3m,φ8

シロ WHT 3 GND *2 4 4 DTR


36 25 GND 5 5 GND
6 6 DSR
*4 *4
7 7 RTS
8 8 CTS
9 9 NC
2B03 16P0209
FUSE *4 *4
15A(12V) *3
7A(24V) MJ-A3SPF 12-24VDC
12-24 VDC MJ-A3SPF0018-050ZC,5m,φ11 1 DC(+)
C シロ WHT
クロ BLK 2 DC(-) DTE 17JE-23090
-02(D8C)
3 GND 1 *2 FM14-7P
2 CO-0.2x2P,MAX.15m 1 EGCプリンタ
100-115/ RXD RXD
*1 2B10 16P0214 EGC PRINTER
200-230 VAC DPYC-2.5 TXD 3 2 TXD
PP-505 (+) 1 08S0157,3m
1φ,50/60Hz AC AC/DC 24VDC + 4 3 0V 24VDC
*1 IN 銅板 *2
電源ユニット OUT - COPPER STRAP GND 5 (-) 2
24 VDC DPYC-4 + DC AC/DC POWER W=30,1.2m 6 7 NC
- IN GND
SUPPLY UNIT 7 *4 08S0087
E PR-240 *2 8
PE *1 9 FM14-7P *2 FM14-7P
IV-2sq. FM14-5P
CO-0.2x5P,MAX.100m
保護アース *4
1 RXD 1 1 RXD-H EGCプリンタ
2 TXD 2
P
2 TXD-H EGC PRINTER
3 NC 3
P
3 FG PP-505 *2 *5
4 NC 4 4 TXD-C
5 5 5 1 08S0157,3m
0V *2 RXD-C (+) 24VDC
*4 I/F BOX 6 6 +9V (-) 2
OP16-14 7 7 NC
注記 GND
*4 *4 08S0087
*1)造船所手配。
*2)オプション。
D *3)工場にて取付済み。
*4)コネクタクランプでアースに落とす。
*5)TB基板(16P0116)が必要。
*6)終端のIC-307はジャンパー設定を変更する。
*7)アンテナケーブルは切断して使用しないこと。

NOTE DRAWN TITLE


*1. SHIPYARD SUPPLY. 30/Mar/2010 T.YAMASAKI FELCOM 15
CHECKED
*2. OPTION.
30/Mar/2010 T.TAKAHASHI
名称 インマルサットC船舶地球局
*3. FITTED AT FACTORY. APPROVED
*4. GROUND THRU CONNECTOR CLAMP. 相互結線図
*5. TB BOARD (16P0116) REQUIRED. SCALE MASS NAME
*6. CHANGE SETTING OF JUMPER IN IC-307 TO TERMINATE. CO-0.2x2P: CO-SPEVV-SB-C 0.2x2P,φ10.5 kg INMARSAT-C MES
CO-0.2x5P: CO-SPEVV-SB-C 0.2x5P,φ13.5 DWG No.
*7. DO NOT SHORTEN ANTENNA CABLE. C5635-C01- S INTERCONNECTION DIAGRAM
FURUNO ELECTRIC CO., LTD.

Downloaded from www.Manualslib.com manuals search engine

You might also like