Example:
Installed
capacity :163304 MW
Operating Capacity : 130643 MW @ 80% PLF
Example:
Installed
capacity :34444.12 MW
Operating Capacity : 27555.3 MW @ 80% PLF
Fluctuation load
Coal quality
Capacity utilization
Three-
pronged Fine-tuning
approach
Technology up
gradation
© Confederation of Indian Industry
Best Practices
358.20C
Saturation Temp
of steam
OPETATING DESIGN
UNIT HEATER
DCA TTD DCA TTD
1 HPH6 11.6 3.37 6.8 2.6
HPH5 2.4 7.00 6.8 2.6
2 HPH6 18.2 3.36 6.8 2.6
HPH5 5 7.21 6.8 2.6
yes yes
Increase in Did TTD Did DCA Check drain
steam flow increase increase valve passing
NO NO
yes yes
Check for lower Did DCA High heater Reduce heater
heater level increase level? level
NO
NO
Increase heater
level
Check for
& reduce DCA
heater tube Partition plate
leakage & may be leaking
increased
drain flow
6 – 18 m/sec
Possible reasons are
Due to duct bends (900)
AS IS Design Modification
Turbulence is
observed in the
rectangular sections
No Turbulence is
observed in the new
design
© Confederation
© ConfederationofofIndian
Indian Industry
Industry
Optimise the pressure drop in flue gas
circuit
Recommendation
Potential area to do CFD analysis and reduce pressure
drop
At least 15 – 20 mmwc reduction in pressure drop possible
Background
4 x 135 MW IPP:
4 Cooling water pumps for condenser cooling and
auxiliary cooling water requirements
Common for all 4 units
Operating condition
CW operate at discharge pressure of 0.21-0.23 Mpa
Range across the condenser – 7.5 Deg C
Cooling Tower
Units 1 & 2 Units 3 & 4
Forebay
Existing System
The 3 pumps operate with
Discharge pressure – 0.18 to 0.19 Mpa
Range across condenser
Increased from 7.5 to 9.5 Deg C
Benefits
Reduction of power by stopping one pump
Loading of cooling tower reduced with reduction in
total water flow quantity
Savings
Theoverall savings achieved from this project by
stopping one pump was
2350 kw
Investment - NIL
Recommendation
MOTOR
BOOSTER PUMP
PRESSURE VARIABLE SPEED COUPLING
STAGE
Magnetic coupling
Principle of operation
Ithas a magnetic rotor surrounded by a conductor rotor.
Both the rotors are never in contact with each other
Torque is transmitted through an air gap in the coupling
by the relative motion between the conductor rotor and
extremely powerful permanent magnets contained in the
magnetic rotor.
This relative motion creates a magnetic field in the
conductor thereby transmitting torque
Magnetic coupling:
Advantages
The signal could be given directly
from the DCS (4-20 mA)
No direct coupling hence lesser
stress on the motor
No harmonics
No separate unit/ space required
unlike VFD panel
Tolerates misalignment, thermal
expansion and vibration issues
Magnetic Adjustable Speed
Operates with any kind of motor
Drive for 190 KW ID Fan
Slip of 2-3%
Motor Shaft Motor Shaft Load Shaft Motor Shaft Load Shaft
72
70
68
66
64
62
60 13:37
11:05 12:15 14:36 15:58
Time
Increase in leakage
On Load On Load
PSIG
C/A Bypassed
© Confederation of Indian Industry
Air In Air Out
On Load Unloaded
K V Kiran Kumar
Counsellor
Confederation of Indian Industry
CII - Godrej Green Business Centre, India