You are on page 1of 6

Your Complete Vascular Lab

Peripheral-Vascular Examinations
Arterial and venous testing
Ankle-Brachial-Index (ABI)
Pulse Volume Recording (PVR)
Photo Plethysmography (PPG)
Light Reflection Rheography (LRR)
Spectral CW Doppler 5 and 8 MHz

Cardio-Vascular Examinations
Pulse Wave Velocity (PWV)
Pulse Wave Analysis (PWA)
Central Aortic Pressures
Augmentation Index (AIx)

rterial Stiffness
Determination of A

Systems for the Health Conscious


Your Complete Vascular Lab…

…for Peripheral and Cardio-Vascular Examinations

All at Your Fingertips Pure Innovation

The VICORDER® fits well in the palm of your VICORDER® does not built on a large cart, nor
hand. Unlike anything else on the market of this on redundant hardware. Via a fast USB adaptor,
size it integrates all the functions of a complete additionally serving as a power supply, the handy
‘large’ vascular lab, offering both peripheral and VICORDER® can be connected to (almost) any
cardio-vascular testing capabilities. Equipped standard PC. In combination with a notebook
with modern sensor technology the VICORDER® the VICORDER® becomes an ultra portable
features bilateral pressure measurement, Pulse vascular testing system. Including all accessories
Volume Recording, Photo Plethysmography, and for bilateral testing, VICORDER® and a note-
high resolution spectral Doppler sonography. book will fit into a normal briefcase, allowing
This advanced multi-sensor technology caters you to apply the VICORDER® wherever you
well to a very broad application in functional need it, in your lab, bedside, in your outpatient
arterial and venous examinations including department, or during visits.
convenient protocols for arterial stiffness
testing. The compact VICORDER® case,
weighing less than 600 grams, houses medical Highest Accuracy
high tech: Digitally controlled pneumatics for
inflating and bleeding the cuffs, sensor electro- With an A/D signal conversion of 22 Bits or Reliable Digital Electronics
nics, and an integrated remote control for more than 4 million points, VICORDER® yields
executing all tests right next to the patient. a resolution exceeding that of conventional VICORDER® means less redundant hardware,
A true miracle in efficiency and user friendliness instruments by a factor of 1000 or more. This miniaturized sensor electronics, high resolution
with remarkable features right at your effects particularly the display of pulse wave signal conversion and fewer mechanical parts.
fingertips! forms showing every fine detail in high fidelity. All these features combined lead to an unprece-
While offering excellent accuracy and ease of dented compactness, enhanced reliability, and
operation VICORDER® minimizes electronics reduced service cost at higher availability.
when compared to other devices. The separation
of the test module from the PC reduces cost and
offers flexibility in future software development
and adaptation of new computer hardware.
…for Peripheral-Vascular Examinations

Comprehensive Testing Capabilities • Bidirectional CW Doppler


• 5 and 8 MHz Probes
Featuring a flexible yet simple user interface • High Resolution Spectral Analysis
VICORDER® offers all relevant arterial and • Ankle-Brachial-Index (ABI)
venous function tests. Routine protocols for the • Toe-Brachial-Index (TBI)
most widely applied tests, such as ABI or pulse • Segmental pressures
wave analysis, are included and can be operated • Finger, toe and penile pressures
in different modes, either by using Pulse Volume
• Pulse Volume Recording (PVR)
Recording (PVR), Photo Pulse Plethysmogra-
• Photo Pulse Plethystmography (PPG)
phy (PPG) or Doppler Sonography. Segmental
as well as digital pressures may be determined • Stress Test
bilaterally by PPG or unilaterally by Doppler. • Thoracic Outlet Syndrome Test
Pressure measurements can be repeated by • Light Reflection Rheography (LRR)
either modality, with a mean of tests or single • Venous Reflux Test
test results reported. In a special protocol high • Venous Outflow Test
resolution wave forms from PVR or PPG can be
combined with pressure measurements reducing
testing time. Most protocols offer anatomical Spectral Doppler and PPG
3-D-graphics for user-guidance and impressive
documentation in various formats. For venous Featuring high resolution spectral analysis, the
function testing venous reflux and venous integrated Doppler offers 5 and 8 MHz CW
outflow protocols are also integrated. probes, capable of safely insonating small
vessels, even at compromised perfusion, just as
good as large and deep vessels. The VICORDER®
Proven Tests – Fast and Reliable Doppler also comprises protocols for insonating
Results brain supplying and periorbital arteries. Both,
Doppler audio signal and spectra, are of highest
VICORDER® integrates the most important quality and will satisfy even the most demanding
arterial and venous tests, proven protocols in a application.
most modern format. All tests can easily be For pressure measurement in the peripheral
performed and documented within a few minutes. arteries either Doppler or Photo Pulse
Plethysmography (PPG) can be used. Due to its
dual channel, bilateral approach and its simple
and fast operation PPG is the modality of choice for routine and screening examinations.
The remote control, an important feature in
Doppler testing, has been directly integrated
into the VICORDER® enclosure which can be
placed right next to the testing site.

 
 


 
 


 
   

  
  
  

    
   
  
 
 
 


  
 

   Limb
 


 
Lo er
w 

 

  
 

  



 
   
  
   
  
 
   
  
    
  

  

  


 
 
   
 
 



  
 

 
  



 





 





 




 
 

 

  

 
 

 
    

 

    

        

    
   
      
  
    
 
 
  
   
    
   

  


 





 
 

ures
Central Aortic Press
Arterial Stiffness –

…for Cardio-Vascular Examinations

From Vascular Screening to Assess- tests can conveniently be performed by assisting optional VICORDER® Pulse Wave Analysis
ment of Cardio-Vascular Risk medical staff. (PWA) yields the transformed central aortic
PWV provides assessment of arterial damage pressure wave form. Reliable scaling of systolic
“It’s not just about the legs”, a recent key and is of significant prognostic power in related and diastolic brachial and central pressures is
publication states clearly: “ABI is a biomarker diseases, such as hypertension, diabetes, or attained by an integrated oscillometric blood
of cardio-vascular risk” [1]. In internal medicine chronic kidney disease, where it should be pressure measurement. Pulse Pressure (PP),
and cardiology, no other simple functional carried out as routinely as echocardiography, Augmentation Pressure, Augmentation Index
parameter has such high reliability, with both 24-h blood pressure monitoring or glucose (AIx) and other important assessments such as
sensitivity and specificity exceeding 90%. The tolerance testing. Cardiac Output and Total Peripheral Resistance
paramount importance of the ABI in diagnosing Please note: The VICORDER® determined PWV are reported.
peripheral obstructive arterial disease has is not an estimate derived from a peripheral
been documented for years. Now there is wave form but a direct physiological measure, With only an upper arm cuff inflated, evaluation
also strong evidence in its value of early taken synchronously from carotid and femoral of central aortic pressures will require less than
and reliable detection of cardio-vascu- sites. five minutes and is most convenient for operator
lar risk, which coincides with a and patient. The test protocol is automated and
rising prevalence of abnormal virtually operator independent.
ABIs. As an example, in Non-invasive Determination of Cen-
Germany about 20% of all tral Aortic Pressure
patients visiting a private Perfectly Suited for Scientific Studies
physician had an ABI Meanwhile major European scientific societies
below 0.9 carrying a involved in the battle against hypertension and Featuring fast and simple operation, a superior
substantial risk of heart other related diseases included the determinati- signal resolution, optimum testing flexibility, low
attack or stroke [2]. on of central aortic pressure in their official intra-subject variability, comprehensive data
recommendations [4]. In patients at risk, management and export facilities, VICORDER®
brachial pressure may deviate substantially has proven its value in clinical applications,
From Peripheral from central aortic pressure. As the increase in scientific research and drug studies.
Obstructive pulse wave velocity results in an earlier
Arterial Disease reflection of the pulse wave, augmentation of
to Vascular the central pressures may occur, leading to an
Stiffness increase in systolic and a fall in diastolic
pressures. Stroke, increased left ventricular
Besides screening of the load, reduced coronary perfusion, and left
ABI as a risk indicator, the ventricular hypertrophy are causal complica-
current scientific literature tions.
[3] now advocates the
determination of the elastic Only an upper arm cuff is needed for recording
properties of larger central arteries. Reduced and averaging the brachial pulse wave while the
elasticity and increased arterial stiffness is
associated with an array of metabolic and
cardiac diseases. With the non-invasive, fast and
patient-friendly determination of vascular For special applications, e.g. in a CT or MRI,
stiffness VICORDER® is the tool of choice for testing can be performed up to 5 meters away
both clinical examinations and scientific studies. from the VICORDER® instrument.
As a stand-alone test or in combination with the
ABI, Pulse Wave Velocity (PWV), a surrogate of
vascular stiffness, can be obtained in less than
five minutes. Due to its simplicity and high
intra-subject repeatability, the PWV and ABI

References: [1] Perlstein et al., Circulation 2009, [2] Diem et al, Europ Heart J 2006, [3] Weber et al., J Hypertonie 2008, [4] European Society of Hypertension (ESH) and of the Europe-
an Society of Cardiology (ESC), J Hypertens 2007
As Easy and Fast as 1, 2, 3!

Testing in Less Than Five Minutes

Optimal Operation – Optimal Results editing of anamnesis, findings and comments. integrated, the convenient multi-functional
Data may be archived locally or on a server. Con- remote control enhances the flow of test proce-
For optimal use of the many VICORDER® venient backup functions assure data integrity dures without any need of mouse or keyboard.
testing capabilities all exam protocols are and safety. Operating under MS Windows® 7,
automated, yet user configurable. Animated XP Professional, or Vista, the VICORDER® The automated determination of the Brachial-
3-dimensional graphics assist in simplifying program can be installed within minutes. Test Arm-Index (ABI) and Pulse Wave Velocity
testing procedures and provide impressive docu- reports, impressively documenting every exam (PWV) in less than five minutes serves as a good
mentation. Examinations can easily be delega- detail, may be printed locally or remote, stored example of the unique efficiency built into the
ted, especially for screening, testing in private in pdf format, sent by eMail, or attached to the VICORDER®. Just look and see!
practice, and field studies. From vessel labelling patient chart in a practice computer system
to gain control or cuff bleed rate, all examina- (PCS) or hospital information system (HIS). Please visit our website at www.vicorder.eu for
tions may be configured to your needs, just be For research purposes data can be exported and videos demonstrating the speed and efficacy of
making adjustments as you go along, recorded in efficiently evaluated in csv or xls format files. VICORDER® test procedures.
a user defined protocol. All test results including Due to its reliability, accuracy, and data integrity
wave forms are stored for retrieval and post- VICORDER® has been chosen by reputed scien-
processing at any time. tists for multi-center studies.
The ready-to-network VICORDER® comprises a The light VICORDER®, weighing less than 600 g,
complete patient record management including can be placed right next to your patient. Directly

Pulse Wave Velocity (PWV)

1 2 3 4
min min min min

Ankle-Brachial-Index (ABI)

1 2 3 4
min min min min
Your Complete Vascular Lab

Unique Specifications

Design: j.tratz@sichtbereich.de | FRANKFURTER FUENF


All Inclusive!
Technical Specifications
VICORDER® comes complete with Doppler probes, cuffs, PPG sensors, and the VICORDER
program package, easily to be installed on your PC of choice. No expensive disposables, no hidden VICORDER® Sensor module
cost. When applying the VICORDER® in your daily practice, you will appreciate the profound Dual channel pressure measurement
technical expertise and know-how in vascular testing and Doppler sonography that has been Dual channel Photo Plethysmography (PPG)
incorporated in this instrument. CW Doppler with 5 and 8 MHz Doppler probes
Profit from this experience that makes VICORDER® amazingly effective, user friendly and cost Digitally controlled cuff pumps and valves
efficient! 22 Bit Analog-Digital conversion
Integrated remote control
Power supply through USB
Fast USB adaptor 2.0
Size (WxHxD) 10.6 x 4.0 x 17.0 cm
Weight ca. 600 g
USB cable approx. 2.50 m
Pressure hoses approx. 2.00 m
(extendable up to 5.00 m)
PPG cable approx. 2.00 m
Doppler cable ca. 2.00 m

VICORDER® Program Package


MS Windows® 7, XP Professional, or
Vista compatible
Comprehensive data management
Local or remote archive, auto backup
Automated protocols
User configurable programs
Doppler spectral analysis (256 point FFT)

VICORDER® complies with all relevant safety regulations


(medical CE, IEC, FDA). Technical innovation may require
modifications without notice. MS Windows® is a registered
trade mark of Microsoft Corp.
VICORDER® is a registered trademark of SMT medical,
Wuerzburg, Germany and Skidmore Medical Ltd., Bristol, UK.
www.smt-medical.com, www.vicorder.eu

SMT medical GmbH&Co.


Im Kreuz 9
Phone +49 (931) 3 29 33-0
Fax +49 (931) 3 29 33-29
Systems for the Health Conscious
97076 Wuerzburg info@smt-medical.com
Germany www.smt-medical.com

You might also like