You are on page 1of 3

Equipment/Pump List

No. Item Name Quantity Type Design Design


No. Temperature(°C) Pressure(atm)
1. R01 Electrolyser Cell 685 Reactor 85 1
Membrane
2. P01 Pump 2 Centrifugal 85 1

3. E01 Cooler 1 1 Shell and 40 1


Tube Heat
Exchanger
4. E02 Cooler 2 1 Shell and 15 1
Tube Heat
Exchanger
5. E03 Liquefaction 1 Shell and 18 6.9
Tube Heat
Exchanger
6. M01 Compressor 1 Reciprocating 26 7.9

7. D01 Dryer 1 Packed 15 1


column and
Tray
8. E04 Cooler 3 1 Shell and 40 1
Tube Heat
Exchanger
Instrument List

No. Control Location Sensor/element Control Design value


Items tag number by
1. Pressure After membrane PT-01 PV-01
electrolyzer
2. Level of After membrane PIC-01 PV-01
Pressure electrolyzer
3. Temperature - After membrane TC-01 TCV
water electrolyzer
4. Temperature After cooler 1 TI-01 TIC-01 40°C
– wet chlorine
gas
5. Temperature Before cooler 1 TI-02 TIC-02 40°C
– cooling
water
6. Temperature After cooler 2 TI-03 TIC-03 15°C

Chlorine gas
7. Temperature Before cooler 2 TI-04 TIC-04 15°C
– chilled
water
8. Pressure of Before cooler 1 PI-02 PV-02 1 atm
Cl2 gas
9. Pressure of Before cooler 2 PI-03 PV-03 1 atm
Cl2 gas
10. Pressure of After dryer PI-04 PV-04 8 atm
dried chlorine
11. Pressure of After compressor PI-05 PV-05 7 atm
compressed
chlorine gas
12. Flow rate – After membrane FI-01 FV-01 110000kg/hr
Chlorine gas electrolyzer
13. Flow rate – After cooler 2 FI-02 FV-02 110000kg/hr
Chlorine gas
14. Flow rate – After dryer FI-03 FV-03 110000kg/hr
Chlorine gas
15. Temperature After dryer TI-05 TIC-05 26°C
–dried
chlorine
16. Temperature After compressor TI-06 TIC-06 18°C
– compressed
gas
17. Temperature After liquefaction TI-07 TIC-07 18°C
–liquid
chlorine
18. Pressure – After liquefaction PI-06 PV-06 7 atm