Coolani

Window/Wall Air Conditioner

Find out more at


www.greeonline.com
The Benefits
The Benefits

3-Speed Fan, with Auto Mode


3-Speed
In auto the fanFan,
speedwith Autoadjusts
automatically Modeas the room
temperature changes.
In auto the fan speed automatically adjusts as the room temperature changes.

Fresh
Fresh Air Ventilation
Air Ventilation
Adjust the slider to ventialte and expel smoke and odours from the room.
Adjust the slider to ventialte and expel smoke and odours from the room.
Anti-Corrosion Protection Features
Anti-Corrosion Protection Features
Hydrophilic Blue Fin Coils. Galvanised and painted slide out chassis
Hydrophilic Blue Fin Coils. Galvanised and painted slide out chassis
Digitial Display with On/Off Button
IfDigitial
the remoteDisplay
is lost the with On/Off
air conditioner canButton
be run via the digital control
If the on
panel remote is lost
the unit. Thethe airdisplay
unit conditioner
can becan be run
turned off via
via the
the digital
remotecontrol panel on the unit. The unit
control.
display can be turned off via the remote control.
Self-Diagnostics
Self-Diagnostics
In the unlikely event of a malfunction, the malfunction code will be
displayed aiding a speedy repair.
In the unlikely event of a malfunction, the malfunction code will be displayed aiding a speedy repair.

Check
Check Filter
Filter Indicator
Indicator
This feature is a reminder to clean the filter for more efficent operation.
This LED
The feature
lightis will
a reminder to after
illuminate clean250
thehours
filter for more efficent operation.
of operation.
The LED light will illuminate after 250 hours of operation.
Auto Swing Air Direction
AutotheSwing
When Air Direction
swing button is pressed on the remote control the air direction
louvers willswing
When the start to rotate
button is automatically.
pressed on the Press the swing
remote controlbutton
the airagain to louvers will start to rotate
direction
stop and set at Press
automatically. the desired direction.
the swing button again to stop and set at the desired direction.

Clock with
Clock withOn/Off
On/OffTimer
Timer
The clock must be set on the remote control to enable the timer to be
The clock must be set on the remote control to enable the timer to be set to come on or turn off at
set to come on or turn off at a certain time.
a certain time.
Sleep Function
Sleep
The sleepFunction
function changes the set point temperature after one and then
The hours.
two sleep function changes
This follows thenatural
a more set point temperature
sleep pattern. after one and then two hours. This follows a
more natural sleep pattern.
Wireless Remote Control
(MODEL YS1FA) – 5 Operation Modes

Auto
Operation is selected based on current room temperature.

Cooling plus Energy Saver Mode


Energy saver mode switches the fan off once the air conditioner
has reached the set point of the thermostat.

Drying/Dehumidifying
Heating
Fan Only

Heating and cooling capacities are based on AS/NZ 3823.1.1.

Running current is rated at AS/NZ 3823.1.1 standards and does not include compressor start-up or power supply
variations. Failure to comply with relevant Government regulations may void the warranty.

Due to continuous product improvements, specifications are subject to change without prior notice.

GREE ELECTRIC APPLIANCES INC. OF ZHUHAI


Based in the thriving industrial city of Zhuhai in China, GREE Electric Appliances is the world’s
largest specialised air conditioning enterprise. With nine manufacturing plants producing over
7,000 different models, sold to over 100 countries.

GREE employs over 5,000 R & D staff. This has allowed them to
develop a wide range of quality products featuring energy saving
technology, intelligent temperature control, smart defrosting and
a wide range of filter options.

GREE’s use of quality materials and state of the art manufacturing


facilities has resulted in GREE maintaining its No 1 residential air
conditioning global sales position since 2005. With more than 200
million users of residential air-conditioners globally, it’s a quality
you can trust.
Gree Coolani Window
Gree Coolani Window Wall UnitsGJH09AF-K3RNB9D
Wall Units GJH09AF-K3RNB9D
GJH12AD-K3RNB9D
GJH12AD-K3RNB9D
GJH8AC-K3RN9D GJH8AC-K3RN9D
GJH21AC-K3RNB9D
GJH21AC-K3RNB9D

Australia Australia AC2080 AC2080


AC2310 AC2310
AC2315 AC2315
AC2320 AC2320
Realcold Part # Realcold Part #
New Zealand New Zealand AC5025 AC5025
AC5026 AC5026
AC5027 AC5027
AC5028 AC5028

Performance Performance

Control Method Control Method Remote Control Remote Control


Power Supply Power Supply 1 phase 220~240V
1 phase
50Hz 220~240V 50Hz
Cooling Cooling 2.7 2.7 3.9 3.9 5.3 5.3 6 6
Capacity T1 Capacity T1 kW kW
Heating Heating 2.4 2.4 3.6 3.6 5.0 5.0 5.5 5.5
Cooling Cooling 0.81 0.81 1.18 1.18 1.6 1.6 1.83 1.83
Input T1 Input T1 kW kW
Heating Heating 0.72 0.72 1.09 1.09 1.5 1.5 1.76 1.76
Cooling Cooling 2 2 2 2 2 2 2 2
Energy Label Energy Label kW kW
Heating Heating 2 2 2 2 2 2 1.5 1.5
AEER Cool T1 AEER Cool100%
T1 100%
W/W 3.27
W/W 3.27 3.36 3.363.28 3.283.27 3.27
ACOP Heat T1 ACOP Heat100%
T1 100%
W/W 3.25
W/W 3.25 3.41 3.413.25 3.253.17 3.17
Moisture RemovalMoisture Removal I/h 0.43I/h 0.43 0.62 0.620.99 0.991.14 1.14

Indoor Indoor
db 49/47/45
db 49/47/45
53/51/49 53/51/49
55/53/51 55/53/51
56/54/52 56/54/52
H/M/L H/M/L
Sound Pressure Level
Sound Pressure Level
(JIS C9612) (JIS C9612)
Outdoor Outdoor
db 57/55/53
db 57/55/53
58/56/54 58/56/54
63/60/58 63/60/58
64/62/60 64/62/60
H/M/L H/M/L

l/s 133l/s 133 188 188 239 239 239 239


Operating Temperature
Operating
Range
Temperature Range
ºC ºC –7ºC~43ºC –7ºC~43ºC

Electrical Electrical

Power Supply (Indoor)


Power Supply (Indoor) 1phase 220 ~ 240V
1phase
50Hz220 ~ 240V 50Hz
Recommended Circuit
Recommended
Breaker Circuit Breaker
Amp 10
Amp 10 15 15
Rated Current Rated Current Amp 7.3Amp 7.3 7.3 7.3 9.1 9.1 10.1 10.1
Power Supply Connector
Power Supply Connector 10 amp plug 10 amp plug 15 amp plug 15 amp plug

Dimensions and
Dimensions
Weights and Weights

External Diamensions
External
(W Diamensions
x H x D) (W mm
x H x D)560 × 375mm
× 668 560 ×660
375× ×428
668× 700 660 ×660
428××428
700770 660660
× 428
× 428
770× 770 660 × 428 × 770
Nett Weight Nett Weight kg 44 kg 44 57 57 68 68 70 70
Refrigerant R410A
Refrigerant R410A kg 0.75kg 0.75 1.1 1.1 1.3 1.3 1.34 1.34
Loading QuantityLoading
(20' Container)
Quantity (20' Container) 135 135 84 84 72 72 72 72

2 YEAR

2 5
COMMERCIAL
WARRA NTY
YEAR YEAR
COMMERCIAL DOMESTIC
WARRA NTY WARRA NTY
5 YEAR
DOMESTIC
WARRA NTY

For Installation
For Installation Forand
and Installation
Sales: and Sales:
Sales: For Parts andFor
Warranty:
Parts and Warranty:
For Parts and Warranty:

Contact: Contact:
AUS 1300 7325
AUS2653
1300 7325 2653
NZ 0800 11 NZ
66 90
0800 11 66 90
www.realcold.com
www.realcold.com

www.greeonline.com
0800 BUY GREE (NZ)
GREE
NZ & AU
1800 GREE 4 ME (AU) NOW ONS