You are on page 1of 9

PRODUCT LINEUP

AIR TO WATER

Residential

AIR TO WATER Complete Solution meets various needs


The clean energy produced by WATERSTAGE™ reliably
delivers “comfort” to all spaces in the home up to the
living room, bedrooms, bath, and swimming pool.

280 Home Heating Air to Water Overview


282 Technology
283 WATERSTAGE™ Lineup

284 Split Type/Split DHW Integrated Type *New Super High Power series
286 Case Studies
Installation Limitations
288 Optional Parts
290 Specifications & Dimensions

What's a Heat Pump ?


Absorbing free energy from the atmosphere. Heat pump
system requires only 1 kW of electricity to generate 3 to 5 kW
Room Heating thermal energy.

AIR TO WATER
3 to 5 kWh
1 kWh of heat
Domestic Hot Water Electricity

Comfort heating

2 to 4 kWh
Ambient air
Floor Heating

278 279
PRODUCT LINEUP

AIR TO WATER

Home Heating
Air to Water Overview

Wide range lineup suited for regional characteristics, family structure, and
application. We provide various products to meet your needs from High
Power via heating-centered series to reasonably-priced compact series.

Solar Connection

Room
Heating
Height

620 mm* 300 Liter

DHW tank
Outdoor unit + DHW Tank
DHW tank (option) can be used to supply hot
Floor
Heating
Appearance-oriented water by connecting it to the system.
Domestic
Hot water Hydraulic unit compact outdoor unit
+ Boiler
Split type Comfort series
By combining existing boiler, powerful
For Comfort series, optimized flow temperature heating can be performed even at low
control is realized by DC inverter technology. outdoor temperature.
Swimming
*: Outdoor Unit: WOHA060LFCA/WOHA080LFCA *optional part necessary
NEW
Pool
Super High Power series
Single-phase: 16kW
3-phase: 15/17kW
Internet Remote control
system

Stylish space saving solution with


built-in DHW tank Hydraulic
indoor unit
Outdoor Smartphone
sensor control
Remote control
(Option) Wireless
Outdoor room thermostat
unit (Option)

AIR TO WATER
Web-server
Floor heating Radiator
(Option)

For Room heating & domestic Hydraulic indoor unit DHW tank
or

High leaving water temperature hot water


Space is saved drastically due
High leaving water temperature 60°C Outdoor unit and hydraulic indoor unit can be installed Smart control
kept down to -20°C outdoor temperature freely, so installation is easy. Since hydraulic indoor unit is to built-in DHW tank. User’s needs are supported by offering a variety of
without using backup heater. installed inside a house, freezing of circulated water can
be prevented. A larger heating capacity can be performed Existing boiler can be replaced easily. A larger controls, such as individual control and remote control
flexibly by using more units in cascade connection. heating capacity can be performed flexibly by using options.
more units in cascade connection.

280 281
PRODUCT LINEUP

AIR TO WATER

Technology WATERSTAGE™ Lineup


Capacity (kW) 5 6 8 10 11 14 15 16 17
Super High Power
series
Single phase NEW

Hydraulic Indoor Unit/ WSHG160DJ6 /


Outdoor Unit WOHG160LJL

High Efficiency Super High Power


series
3 phase NEW

Hydraulic Indoor Unit/ WSHK170DJ9 / WSHK170DJ9 /


Outdoor Unit WOHK150LJL WOHK170LJL
For Outdoor Unit For Hydraulic Indoor Unit
High Power series
Twin Rotary Compressor with Linear Control Class A pump Single phase

Split
Injection Port Energy saving
Hydraulic Indoor Unit/ WSHG140DG / WSHG140DG /
It realizes the high condensing pump with constant Outdoor Unit WOHG112LHT WOHG140LCTA
temperature without overheating volume or pressure
discharge gas temperature by Linear adjustment function. High Power series
3 phase
Control Injection process during
compression. Therefore, the condensing
Hydraulic Indoor Unit/ WSHK160DG / WSHK160DG / WSHK160DG /
temperature rises up higher than normal Outdoor Unit WOHK112LCTA WOHK140LCTA WOHK160LCTA
circuit. A higher hot water temperature
is realized by controlling the injection Energy efficiency class Comfort series
WSHK170DJ9
amount according to the usage state. Linear Control
Injection Port
Hydraulic Indoor Unit/ WSHA050DG / WSHA100DG / WSHA100DG / WSHA100DG /
Outdoor Unit WOHA060LFCA WOHA060LFCA WOHA080LFCA WOHA100LFTA
Optimized circuit = Stainless steel buffer tank
higher water temperature Accurate temperature control Super High Power
Heat exchange amount is 25% higher than series
by DC inverter technology Single phase
previous model. Energy saving performance
NEW

Normal is improved. Hydraulic Indoor Unit/ WGHG160DJ6 /


refrigerant Outdoor Unit
circuit
V-PAM inverter WOHG160LJL
Linear Control technology
Injection Stainless steel Super High Power
buffer tank series
Warm 3 phase NEW

refrigerant flow
Heating cycle Hydraulic Indoor Unit/ WGHK170DJ9 / WGHK170DJ9 /
Outdoor Unit WOHK150LJL WOHK170LJL

Split DHW integrated


High Power series
Single phase
Co-axial
Heat High
Exchanger Heated water
Hydraulic unit Optimum Co-axial Hydraulic Indoor Unit/ WGHG140DG / WGHG140DG /
Temperature

Heat Exchanger Outdoor Unit WOHG112LHT WOHG140LCTA


Linear Control
Injection
High Power series
Constant
3 phase
Evaporator

Time
Hydraulic Indoor Unit/ WGHK160DG / WGHK160DG / WGHK160DG /
Outdoor Unit WOHK112LCTA WOHK140LCTA WOHK160LCTA
Outdoor unit

Comfort series

Hydraulic Indoor Unit/ WGHA050DG / WGHA100DG / WGHA100DG / WGHA100DG /


Outdoor Unit WOHA060LFCA WOHA060LFCA WOHA080LFCA WOHA100LFTA

Easy Control
Hydraulic Indoor Unit Controller

4 Heating mode

AIR TO WATER
1. Automatic mode 3. Comfort mode
EHPA Quality Label SG-Ready Label
Comfort/Reduce mode switching Constant comfort Fujitsu General’s WATERSTAGE* have SG-Ready is a defined standard by BWP***, which makes
automatically according to time temperature obtained the EHPA Quality Label** by tests it possible that the device can be integrated into a smart
program according to the international Standards grid. Heat pumps, which are equipped with the SG-Ready
4. Protection mode EN14511 and EN17025. The EHPA Quality Label, can receive signals from the power grid (and
2. Reduce mode Stand-by mode with anti- Label** is a label that shows the end- e.g. also from PV systems) about the available (unused
Constant reduce temperature frost protection consumer a quality heat pump unit on the renewable) energy (from wind, sun & water). Fujitsu
market. General provides the SG-Ready compatibility to all new
*: only High Power 3phase Heat Pumps series.
**: Check the validity of label at www.ehpa.org/quality/quality-label/ ***BWP: the Federal German Heat Pump Association
282 283
PRODUCT LINEUP

AIR TO WATER

Split Type / High leaving water temperature


Split DHW Super High power series:
High leaving water temperature of 60°C is kept even when outdoor Outdoor Outdoor

Integrated Type
temp. temp.
temperature is down to -20°C without using backup heaters. -20°C Water temp. Water temp.
-22°C
And it’s possible to supply 55°C at -22°C outdoor temperature 60°C 55°C
without backup heater.

Super high power series

High power series: Comfort series:


High leaving water temperature of 60°C is kept even when outdoor Maximum leaving water temperature is 55°C without backup
temperature is down to -20°C without using backup heaters. heater. Hot water supply temperature can be maintained even at
-10°C outdoor temperature.

Outdoor Outdoor
temp. temp.
-20°C Water temp.
-10°C Water temp.
60°C 55°C

Comfort series
Split Type High power series
* If you want to raise the hot water supply temperature, backup heaters can be used for auxiliary operation.

Super high power series High power series Comfort series


Hydraulic indoor unit: Hydraulic indoor unit: Hydraulic indoor unit:
WSHG160DJ6/[3 phase] WSHK170DJ9 WSHG140DG/[3 phase] WSHK160DG WSHA050DG/WSHA100DG
Outdoor unit: Outdoor unit: Outdoor unit:
WOHG160LJL WOHG112LHT/WOHG140LCTA WOHA060LFCA/WOHA080LFCA/
High COP
[3 phase] WOHK150LJL/WOHK170LJL [3 phase] WOHK112LCTA/WOHK140LCTA/ WOHA100LFTA Air to water heat pumps work with much more efficiency and save Seasonal space heating energy efficiency (ηS)
WOHK160LCTA more energy than a traditional heating system.
COP
NEW
164% COP
154% COP
169% 4.52
Energy efficiency 4.33 4.30
class
NEW

Super High power series High power series Comfort series


Hydraulic Hydraulic Hydraulic (15 kW class) (11 kW class) (5 kW class)
indoor unit Outdoor unit indoor unit Outdoor unit indoor unit Outdoor unit
Single Phase/ Single Phase 16kW Single Phase/ Single Phase 3 Phase Single Phase Single Phase Single Phase Condition : Outdoor Temp. 7°C Heating Temp. 35°C.
3 Phase 3 Phase 15/17kW 3 Phase 11/14 kW 11/14/16 kW 5/6/8kW 10kW

2 Zone individual control* Over

Split DHW Integrated Type 50°C


possible
2 Zone individual control (2 under floor heating zones or under floor
heating + radiator zone, etc.)*
Super high power series High power series Comfort series 2nd
Radiator
*: Optional parts are required. Circuit Kit
Hydraulic indoor unit: Hydraulic indoor unit: Hydraulic indoor unit:
WGHG160DJ6/[3 phase] WGHK170DJ9 WGHG140DG/[3 phase] WGHK160DG WGHA050DG/WGHA100DG ~40°C
Outdoor unit: Outdoor unit: Outdoor unit:
WOHG160LJL WOHG112LHT/WOHG140LCTA WOHA060LFCA/WOHA080LFCA/ Floor heating
[3 phase] WOHK150LJL/WOHK170LJL [3 phase] WOHK112LCTA/WOHK140LCTA/ WOHA100LFTA
WOHK160LCTA

AIR TO WATER
NEW
NEW
Automatic heating curve control Radiator
Automatic temperature control
60 with heating curve
Automatic temperature regulation in accordance with heating curve

temperature (˚C)
(Depends on heating terminal and outdoor temperature)

Leaving water
50
Chosen heating curve zone

40

30

Hydraulic Hydraulic Hydraulic Floor heating


indoor unit Outdoor unit indoor unit Outdoor unit indoor unit Outdoor unit
Single Phase/ Single Phase 16kW Single Phase/ Single Phase 3 Phase Single Phase Single Phase Single Phase -20 -15 -10 -5 0 5 10 15 20
3 Phase 3 Phase 15/17kW 3 Phase 11/14 kW 11/14/16 kW 5/6/8 kW 10 kW Outdoor temperature (°C)

284 285
PRODUCT LINEUP

AIR TO WATER

Case Studies

Split Type Split Cascade System Split DHW Integrated Type

2 emitter simultaneous heating (Individual control) 2 emitter simultaneous heating (Individual control) Single heating & Domestic Hot Water
Floor heating + Radiator Floor heating + Radiator Radiator + Domestic Hot Water

Hydraulic Hot water Supply


indoor unit Hydraulic Hydraulic (e.g. for shower)
indoor unit
indoor units

Pump
Pump
Outdoor Outdoor
unit Valve Pump unit
Pump

Radiator Valve
Radiator
Outdoor Radiator
Floor heating units Floor heating
Balancing vessel (Option)

Boiler connected to heating Boiler connected to heating 2 emitter simultaneous heating (Individual control) &
(Boiler + Heating) (Boiler + Heating) Domestic Hot Water
Radiator + Domestic Hot Water
Hydraulic Hot water Supply
indoor unit Hydraulic Hydraulic (e.g. for shower)
indoor units indoor unit
Boiler
Boiler

Valve Pump Pump


Outdoor Outdoor
unit Pump unit
Valve Pump Valve
Radiator Radiator
Outdoor Radiator
Floor heating units
Balancing vessel (Option) Floor heating

Installation Limitations

Equipment Installation Piping and Wiring Split type

Hydraulic
Capacity Pipe diameter
indoor unit
Series range (Liquid/Gas) H1 (m) H2 (m) L (m)

AIR TO WATER
(kW) (mm)
5
350 mm 300 mm 6.35/12.70
Split type Hydraulic indoor unit mini Split DHW integrated type  6
Comfort +20 -20 5-30 Outdoor unit
Hydraulic indoor unit 8 6.35/15.88
• Hydraulic indoor unit is to be hang on
10 9.52/15.88
the wall • Floor stand L H2
11
1840 mm

• Weight 88 kg (including water) 300 mm 1000 mm


• Weight 393 kg (including water) Outdoor unit L H1
mini High power 14 9.52/15.88 +15 -15 5-20
• Space for maintenance should be • Space for maintenance should be
16
respected respected.
15
1000 mm Super
16 9.52/15.88 +15 -25 5-30
High power Hydraulic
17 indoor unit

286 287
PRODUCT LINEUP

AIR TO WATER

Optional Parts

Split Split DHW integrated type Split Split DHW integrated type
Super Super Super Super
High Power Comfort High Power Comfort High Power Comfort High Power Comfort
Product Name Model Name High Power High Power Product Name Model Name High Power High Power
1Ø 3Ø 1Ø 3Ø 1Ø 1Ø 3Ø 1Ø 3Ø 1Ø 1Ø 3Ø 1Ø 3Ø 1Ø 1Ø 3Ø 1Ø 3Ø 1Ø
16 15 17 11 14 11 14 16 5 6 8 10 16 15 17 11 14 11 14 16 5 6 8 10 16 15 17 11 14 11 14 16 5 6 8 10 16 15 17 11 14 11 14 16 5 6 8 10

Cascade Master Kit


UTW-KZSXE — — —          — — — — — — — — — — — — UTW-KCMXE — — —      — — —  — — — — — — — — — — — —
(incl. LPB Clip)

Cascade Slave
UTW-KZDXE — — — — — — — — — — — — — — —          Kit UTW-KCSXE — — —      — — —  — — — — — — — — — — — —
(incl. LPB Clip)
2nd Circuit Kit

UTW-KZSXJ    — — — — — — — — — — — — — — — — — — — — — HMI Kit UTW-KHMXE*3                        

UTW-KZDXJ — — — — — — — — — — — —    — — — — — — — — — UTW-C74TXF*3                        

Remote Wired
Controller

UTW-KBSXD — — —          — — — — — — — — — — — — UTW-C74HXF*3                        

Boiler
UTW-KBDXD — — — — — — — — — — — — — — —          Wired UTW-C55XA                        
Connection Kit
Room
Thermostat

UTW-KBSXJ    — — — — — — — — —    — — — — — — — — — Wireless UTW-C58XD                        

Outdoor Sensor
Balancing Vessel UTW-TEVXA                         UTW-MOSXD                        
Transmitter

UTW-KDWXD RF
DHW Kit             —*1 —*1 —*1 —*1 —*1 —*1 —*1 —*1 —*1 —*1 —*1 —*1 UTW-MRCXD                        
(External) Modules for BSB-Port

200 Liter UTW-T20AXH UTW-KW1XD


300 Liter
            —*1 —*1 —*1 —*1 —*1 —*1 —*1 —*1 —*1 —*1 —*1 —*1 Web Server                        
UTW-T30AXH UTW-KW4XD

DHW Tank

200 Liter UTW-T20BXH


300 Liter
            —*1 —*1 —*1 —*1 —*1 —*1 —*1 —*1 —*1 —*1 —*1 —*1 LPB Clip UTW-KL1XD                        
UTW-T30BXH

Circulating Pump UTW-PHFXG         — — — —         — — — — MODBUS Clip UTW-KMBXJ —*7 —*7 —*7 —*7 —*7 —*7 —*7 —*7 —*7 —*7 —*7 —*7 —*7 —*7 —*7 —*7 —*7 —*7 —*7 —*7 —*7 —*7 —*7 —*7

Service Tool
Swimming
UTW-KSPXD                         (incl. OCI700 UTW-KSTXD *5 *5 *5 *5 *5 *5 *5 *5 *5 *5 *5 *5 *5 *5 *5 *5 *5 *5 *5 *5 *5 *5 *5 *5
Pool Kit
Adapter)

Heat Exchanger for Service Tool


UTW-ESPXA                         UTW-KPSXD *6 *6 *6 *6 *6 *6 *6 *6 *6 *6 *6 *6 *6 *6 *6 *6 *6 *6 *6 *6 *6 *6 *6 *6
Swimming Pool Kit Software

Cooling Kit UTW-KCLXD                         UTY-XWZXZ2 — — —      — — — — — — —      — — — —

AIR TO WATER
External
Connect Kit
Regulation
UTW-KREXD                         UTY-XWZXZ3    — — — — — — — — —    — — — — — — — — —
Extension Kit

*1: DHW operation is possible without DHW Kit and DHW Tank.  : Available — : Not Available
Low Noise *3: 19 Languages included, no separate Eastern European RC necessary. C74TXF: Built in Room Temperature sensor C74HXF: Built in Room temperature and Humidity sensor
UTW-KLNXE         — — — —         — — — —
Kit *4: Eastern European Language(English, Czech Republic, Slovakia, Poland, Turkey, Hungary, Russia, Slovenia, Greece, Serbia)
*5: UTW-KL1XD is required for the connection.
*6: UTW-KW1XD or UTW-KW4XD is required for the connection.
*7: Additional optional part necessary
Drain Pan UTW-KDPXA — — — — — — — —    — — — — — — — — —    —

288 289
PRODUCT LINEUP

AIR TO WATER

Specifications & Dimensions


for Split Type Super High Power Series for Split Type High Power Series

Specifications Tentative Specifications


Hydraulic indoor unit WSHG160DJ6 WSHK170DJ9 WSHK170DJ9 Hydraulic indoor unit WSHG140DG WSHG140DG WSHK160DG WSHK160DG WSHK160DG
Model Name Model Name
Outdoor unit WOHG160LJL WOHK150LJL WOHK170LJL Outdoor unit WOHG112LHT WOHG140LCTA WOHK112LCTA WOHK140LCTA WOHK160LCTA
Capacity range 16 15 17 Capacity range 11 14 11 14 16
Heating capacity 16.00 15.00 17.00 Heating capacity 10.80 13.50 10.80 13.50 15.17
1 kW kW
7°C/35°C floor heating * Input power 3.86 3.46 4.10 7°C/35°C floor heating *1 Input power 2.54 3.23 2.51 3.20 3.70
COP 4.15 4.33 4.15 COP 4.25 4.18 4.30 4.22 4.10
Heating capacity 13.30 13.20 13.50 Heating capacity 10.77 12.00 10.77 13.00 13.50
kW kW
2°C/35°C floor heating *1 Input power 4.25 4.06 4.27 2°C/35°C floor heating *1 Input power 3.44 3.87 3.40 4.15 4.34
COP 3.13 3.25 3.16 COP 3.13 3.10 3.17 3.13 3.11
Heating capacity 14.50 13.20 15.00 Heating capacity 10.38 11.54 10.38 12.20 13.50
kW kW
-7°C/35°C floor heating*1 Input power 5.27 4.55 5.32 -7°C/35°C floor heating*1 Input power 4.32 5.08 4.28 5.13 5.40
COP 2.75 2.90 2.82 COP 2.40 2.27 2.43 2.38 2.50
Space heating characteristics*2 Space heating characteristics*2
Temperature application °C 55 35 55 35 55 35 Temperature application °C 55 35 55 35 55 35 55 35 55 35
Energy efficiency class A++ A++ A++ A++ A++ A++ Energy efficiency class A+ A++ A+ A+ A+ A++ A+ A++ A+ A+
Rated heat output(Prated) kW 14 16 16 17 17 18 Rated heat output(Prated) kW 9 11 11 13 9 11 11 13 13 14
Seasonal space heating energy efficiency(η S) % 125 163 130 164 130 161 Seasonal space heating energy efficiency(η S) % 112 151 113 148 112 154 117 150 117 149
Annual energy consumption kWh 8,757 8,014 9,915 8,606 10,232 9,059 Annual energy consumption kWh 6,704 6,062 8,041 6,824 6,669 5,930 7,803 6,738 9,062 7,408
Hydraulic indoor unit 45 45 45 45 45 45 Hydraulic indoor unit 46 46 46 46 46
Sound power level dB(A) Sound power level dB(A)
Outdoor unit 67 66 67 66 67 68 Outdoor unit 68 69 69 68 70 68 71
Hydraulic indoor unit Specification Hydraulic indoor unit Specification
Power source Single-phase, 230 V 50 Hz 3-phase, 400 V 50 Hz Power source Single-phase, 230 V 50 Hz 3-phase, 400 V 50 Hz
Dimensions H×W×D mm 805 × 450 × 471 805 × 450 × 471 Dimensions H×W×D mm 800 × 450 × 457 800 × 450 × 457
Weight (Net) kg 52.5 52.5 Weight (Net) kg 42 42
Water circulation Min/Max L/min 26.4/57.8 24.0/54.2 27.3/61.4 Water circulation Min/Max L/min 19.5/39.0 24.4/48.7 19.5/39.0 24.4/48.7 27.4/54.8
Buffer tank capacity L 25 25 Buffer tank capacity L 16 16
Expansion vessel capacity L 10 10 Expansion vessel capacity L 8 8
Leaving water temperature range Max °C 60 60 Leaving water temperature range Max °C 60 60
Water pipe connection diameter Flow/Return mm Ø 25.4/Ø 25.4 Ø 25.4/Ø 25.4 Water pipe connection diameter Flow/Return mm Ø 25.4/Ø 25.4 Ø 25.4/Ø 25.4
Backup heater Capacity kW 6.0(3.0kW×2pcs.) 9.0(3.0kW×3pcs.) Outdoor unit specification
Outdoor unit specification Power source Single-phase, 230 V 50 Hz 3-phase, 400 V 50 Hz
Power source Single-phase, 230 V 50 Hz 3-phase, 400 V 50 Hz Current Max A 22.0 25.0 9.0 9.5 10.5
Current Max A 28.00 14.0 14.0 Dimensions H × W × D mm 1,290 × 900 ×330
Dimensions H × W × D mm 1,428 × 1,080 × 480 1,428 × 1,080 ×480 1,428 × 1,080 ×480 Weight (Net) kg 92 99
Weight (Net) kg 137 138 138 Type (Global Warming Potential) R410A (2,088)
Refrigerant
Type (Global Warming Potential) R410A (2,088) Charge kg 2.50
Refrigerant
Charge kg 3.80 3.80 3.80 Additional refrigerant charge amount g/m 50
Additional refrigerant charge amount g/m 50 50 50 Liquid Ø 9.52
Diameter mm
Liquid Ø 9.52 Ø 9.52 Ø 9.52 Gas Ø 15.88
Diameter mm
Gas Ø 15.88 Ø 15.88 Ø 15.88 Connection pipe Length Min/Max m 5/20
Connection pipe Length Min/Max m 5/30 5/30 5/30 Length(Pre-charge) m 15
Length(Pre-charge) m 15 15 15 Height difference Max m 15
Height difference Max m 25/15 (Outdoor unit:Upper/Lower) Operation range Heating °C -25 to 35
Operation range Heating °C -25 to 35 -25 to 35 -25 to 35 *1:The values of heating capacity/input power/COP are based on measurement of EN14511 standard. Usage environment, such as operation of the
*1:The values of heating capacity/input power/COP are based on measurement of EN14511 standard. Usage environment, such as operation of the heating equipment, room temperature, and controller adjustments, may cause disparities between practically determined values and these values.
heating equipment, room temperature, and controller adjustments, may cause disparities between practically determined values and these values. *2:All information of ErP can be available for downloaded from https://www.fujitsu-general.com/global/support/downloads/search/index.html
*2:All information of ErP can be available for downloaded from https://www.fujitsu-general.com/global/support/downloads/search/index.html

Dimensions
Dimensions
Outdoor Unit: Hydraulic Indoor Unit:
NEW
Single Phase: WOHG160LJL
NEW
Single Phase : WSHG160DJ6 Outdoor Unit: Hydraulic Indoor Unit:
3 Phase: WOHK150LJL/WOHK170LJL 3 Phase: WSHK170DJ9 Single Phase: WOHG112LHT/WOHG140LCTA 3 Phase: WOHK112LCTA/WOHK140LCTA/WOHK160LCTA Single Phase: WSHG140DG
3 Phase: WSHK160DG
688 650 650
(515.5)

450 450

400
400
Top view Top view Top view
40 480 12
900 77 31 330 12 900 31 330 12

832,8
800
1080
805
847

AIR TO WATER
471 81 457 81
97 98 97 98
1428

1290
1290

493 479
Heating return Heating flow Heating return Heating flow
Ø25.4 Ø25.4 Ø25.4 Ø25.4

Front view Side view Front view Side view


23.5

21
21

Front view Side view Front view Side view Front view Side view

290 291
PRODUCT LINEUP

AIR TO WATER

for Split Type Comfort Series for Split DHW Integrated Type Super High Power Series

Specifications Specifications Tentative


Hydraulic indoor unit WSHA050DG WSHA100DG WSHA100DG WSHA100DG Hydraulic indoor unit WGHG160DJ6 WGHK170DJ9 WGHK170DJ9
Model Name Model Name
Outdoor unit WOHA060LFCA WOHA060LFCA WOHA080LFCA WOHA100LFTA Outdoor unit WOHG160LJL WOHK150LJL WOHK170LJL
Capacity range 5 6 8 10 Capacity range 16 15 17
Heating capacity 4.50 6.00 7.50 10.00 Heating capacity 16.00 15.00 17.00
1 kW kW
7°C/35°C floor heating * Input power 0.996 1.41 1.84 2.49 7°C/35°C floor heating *1 Input power 3.86 3.46 4.10
COP 4.52 4.27 4.08 4.02 COP 4.15 4.33 4.15
Heating capacity 4.50 4.95 5.65 7.70 Heating capacity 13.30 13.20 13.50
kW kW
2°C/35°C floor heating *1 Input power 1.39 1.53 1.78 2.47 2°C/35°C floor heating *1 Input power 4.25 4.06 4.27
COP 3.24 3.24 3.17 3.12 COP 3.13 3.25 3.16
Heating capacity 4.10 4.60 5.70 7.40 Heating capacity 14.50 13.20 15.00
kW kW
-7°C/35°C floor heating*1 Input power 1.47 1.74 2.23 2.97 -7°C/35°C floor heating*1 Input power 5.27 4.55 5.32
COP 2.79 2.64 2.56 2.49 COP 2.75 2.90 2.82
Space heating characteristics*2 Space heating characteristics*2
Temperature application °C 55 35 55 35 55 35 55 35 Temperature application °C 55 35 55 35 55 35
Energy efficiency class A+ A++ A+ A++ A+ A++ A+ A++ Energy efficiency class A++ A++ A++ A++ A++ A++
Rated heat output(Prated) kW 4 4 5 5 6 7 8 8 Rated heat output(Prated) kW 14 16 16 17 17 18
Seasonal space heating energy efficiency(η S) % 115 169 115 169 118 156 113 155 Seasonal space heating energy efficiency(η S) % 125 163 130 164 130 161
Annual energy consumption kWh 3,026 2,160 3,180 2,505 3,886 3,375 5,415 4,415 Annual energy consumption kWh 8,757 8,014 9,915 8,606 10,232 9,059
Hydraulic indoor unit 46 46 46 46 Hydraulic indoor unit 45 45 45 45 45 45
Sound power level dB(A) Sound power level dB(A)
Outdoor unit 65 60 65 63 65 69 68 69 Outdoor unit 67 66 67 66 67 68
Hydraulic indoor unit Specification Domestic hot water characteristics*2
Power source Single-phase 230 V 50 Hz Load profile L
Dimensions H×W×D mm 800 × 450 × 457 Energy efficiency class A
Weight (Net) kg 42 Energy efficiency(ηwh) % 109
Water circulation Min/Max L/min 8.1/16.2 10.8/21.7 13.5/27.1 18.1/36.1 Annual electricity consumption kWh 941
Buffer tank capacity L 16 Hydraulic indoor unit Specification
Expansion vessel capacity L 8 Power source Single-phase, 230 V 50 Hz 3-phase, 400 V 50 Hz
Leaving water temperature range Max °C 55 Dimensions H×W×D mm 1,841 × 648 × 698
Water pipe connection diameter Flow/Return mm Ø 25.4/Ø 25.4 Weight (Net) kg 166
Outdoor unit specification Water circulation L/min 26.4/57.8 24.0/54.2 27.3/61.4
Power source Single-phase 230 V 50 Hz DHW capacity L 190
Current Max A 12.5 17.5 18.5 Hot water heater capacity kW 1.5
Dimensions H × W × D mm 620 × 790 ×290 830 × 900 × 330 Expansion vessel capacity L 12
Weight (Net) kg 41 42 60 Leaving water temperature range Max °C 60
Type (Global Warming Potential) R410A (2,088) Water pipe connection diameter Flow/Return mm Ø 25.4/Ø 25.4
Refrigerant
Charge kg 1.10 1.40 1.80 Hot water pipe connection diameter mm Ø 19.05
Additional refrigerant charge amount g/m 25 40 Backup heater Capacity kW 6.0(3.0kW×2pcs.) 9.0(3.0kW×3pcs.)
Liquid Ø 6.35 Ø 9.52 Outdoor unit specification
Diameter mm
Gas Ø 12.7 Ø 15.88 Power source Single-phase, 230 V 50 Hz 3-phase, 400 V 50 Hz
Connection pipe Length Min/Max m 5/30 Current Max A 28.0 14.0
Length(Pre-charge) m 15 Dimensions H × W × D mm 1,428 × 1,080 × 480 1,428 × 1,080 × 480
Height difference Max m 20 Weight (Net) kg 137 138
Operation range Heating °C -20 to 35 Type (Global Warming Potential) R410A (2,088) R410A (2,088)
Refrigerant
*1:The values of heating capacity/input power/COP are based on measurement of EN14511 standard. Usage environment, such as operation of Charge kg 3.80 3.80
the heating equipment, room temperature, and controller adjustments, may cause disparities between practically determined values and Additional refrigerant charge amount g/m 50 50
these values. Liquid Ø 9.52 Ø 9.52
Diameter mm
*2:All information of ErP can be available for downloaded from https://www.fujitsu-general.com/global/support/downloads/search/index.html Gas Ø 15.88 Ø 15.88
Connection pipe Length Min/Max m 5/30 5/30
Length(Pre-charge) m 15 15
Height difference Max m 15 15
Operation range Heating °C -25 to 35 -25 to 35
*1:The values of heating capacity/input power/COP are based on measurement of EN14511 standard. Usage environment, such as operation of the
heating equipment, room temperature, and controller adjustments, may cause disparities between practically determined values and these values.
*2:All information of ErP can be available for downloaded from https://www.fujitsu-general.com/global/support/downloads/search/index.html

Dimensions
Dimensions
Outdoor Unit: Hydraulic Indoor Unit:
Outdoor Unit: Hydraulic Indoor Unit: NEW
Single Phase: WOHG160LJL
NEW
Single Phase: WGHG160DJ6
WOHA060LFCA/WOHA080LFCA WOHA100LFTA WSHA050DG/WSHA100DG 3 Phase: WOHK150LJL/WOHK170LJL 3 Phase: WGHK170DJ9
688 645
631
650 599
45.4

395
648 576

(515.5)
Drain port Ø20 450 43
352

320

400

540 125 Top view


40 480 12
832,8
800

Top view Top view 1080

AIR TO WATER
900 77 31 330 12

20 790 62 290

1854
1841
457 81
830
620

97 98
479 1428
Heating return Heating flow
20

Ø25.4 Ø25.4
21

Front view Side view


Side view Front view Side view
Front view Side view
23.5

103
698
Front view Side view Front view Side view

292 293
PRODUCT LINEUP

AIR TO WATER

for Split DHW Integrated Type High Power Series for Split DHW Integrated Type Comfort Series

Specifications Specifications
Hydraulic indoor unit WGHG140DG WGHG140DG WGHK160DG WGHK160DG WGHK160DG Hydraulic indoor unit WGHA050DG WGHA100DG WGHA100DG WGHA100DG
Model Name Model Name
Outdoor unit WOHG112LHT WOHG140LCTA WOHK112LCTA WOHK140LCTA WOHK160LCTA Outdoor unit WOHA060LFCA WOHA060LFCA WOHA080LFCA WOHA100LFTA
Capacity range 11 14 11 14 16 Capacity range 5 6 8 10
Heating capacity 10.80 13.50 10.80 13.50 15.17 Heating capacity 4.50 6.00 7.50 10.00
1 kW kW
7°C/35°C floor heating * Input power 2.54 3.23 2.51 3.20 3.70 7°C/35°C floor heating *1 Input power 0.996 1.41 1.84 2.49
COP 4.25 4.18 4.30 4.22 4.10 COP 4.52 4.27 4.08 4.02
Heating capacity 10.77 12.00 10.77 13.00 13.50 Heating capacity 4.50 4.95 5.65 7.70
kW kW
2°C/35°C floor heating *1 Input power 3.44 3.87 3.40 4.15 4.34 2°C/35°C floor heating *1 Input power 1.39 1.53 1.78 2.47
COP 3.13 3.10 3.17 3.13 3.11 COP 3.24 3.24 3.17 3.12
Heating capacity 10.38 11.54 10.38 12.20 13.50 Heating capacity 4.10 4.60 5.70 7.40
kW kW
-7°C/35°C floor heating*1 Input power 4.32 5.08 4.28 5.13 5.40 -7°C/35°C floor heating*1 Input power 1.47 1.74 2.23 2.97
COP 2.40 2.27 2.43 2.38 2.50 COP 2.79 2.64 2.56 2.49
Space heating characteristics*2 Space heating characteristics*2
Temperature application °C 55 35 55 35 55 35 55 35 55 35 Temperature application °C 55 35 55 35 55 35 55 35
Energy efficiency class A+ A++ A+ A+ A+ A++ A+ A++ A+ A+ Energy efficiency class A+ A++ A+ A++ A+ A++ A+ A++
Rated heat output(Prated) kW 9 11 11 13 9 11 11 13 13 14 Rated heat output(Prated) kW 4 4 5 5 6 7 8 8
Seasonal space heating energy efficiency(η S) % 112 151 113 148 112 154 117 150 117 149 Seasonal space heating energy efficiency(η S) % 115 169 115 169 118 156 113 155
Annual energy consumption kWh 6,704 6,062 8,041 6,824 6,669 5,930 7,803 6,738 9,062 7,408 Annual energy consumption kWh 3,026 2,160 3,180 2,505 3,886 3,375 5,415 4,415
Hydraulic indoor unit 46 46 46 46 46 Hydraulic indoor unit 46 46 46 46
Sound power level dB(A) Sound power level dB(A)
Outdoor unit 68 69 69 68 70 68 71 Outdoor unit 65 60 65 63 65 69 68 69
Domestic hot water characteristics*2 Domestic hot water characteristics*2
Load profile L Load profile L
Energy efficiency class A Energy efficiency class A+
Energy efficiency(η wh) % 88 Energy efficiency(ηwh) % 120
Annual electricity consumption kWh 1166 Annual electricity consumption kWh 880
Hydraulic indoor unit Specification Hydraulic indoor unit Specification
Power source Single-phase 230 V 50 Hz 3-phase, 400 V 50 Hz Power source Single-phase 230 V 50 Hz
Dimensions H×W×D mm 1,840× 648 × 698 Dimensions H×W×D mm 1,840× 648 × 698
Weight (Net) kg 152 Weight (Net) kg 152
Water circulation L/min 19.5/39.0 24.4/28.7 19.5/39.0 24.4/48.7 27.4/54.8 Water circulation L/min 8.1/16.2 10.8/21.7 13.5/27.1 18.1/36.1
DHW capacity L 190 DHW capacity L 190
Hot water heater capacity kW 1.5 Hot water heater capacity kW 1.5
Expansion vessel capacity L 12 Expansion vessel capacity L 12
Leaving water temperature range Max °C 60 Leaving water temperature range Max °C 55
Water pipe connection diameter Flow/Return mm Ø 25.4/Ø 25.4 Water pipe connection diameter Flow/Return mm Ø 25.4/Ø 25.4
Hot water pipe connection diameter mm Ø 19.05 Hot water pipe connection diameter mm Ø 19.05
Outdoor unit specification Outdoor unit specification
Power source Single-phase 230 V 50 Hz 3-phase, 400 V 50 Hz Power source Single-phase 230 V 50 Hz
Current Max A 22.0 25.0 9.0 9.5 10.5 Current Max A 12.5 17.5 18.5
Dimensions H × W × D mm 1,290 × 900 ×330 Dimensions H × W × D mm 620 × 790 ×290 830 × 900 ×330
Weight (Net) kg 92 99 Weight (Net) kg 41 42 60
Type (Global Warming Potential) R410A (2,088) Type (Global Warming Potential) R410A (2,088)
Refrigerant Refrigerant
Charge kg 2.50 Charge kg 1.10 1.40 1.80
Additional refrigerant charge amount g/m 50 Additional refrigerant charge amount g/m 25 40
Liquid Ø 9.52 Liquid Ø 6.35 Ø 9.52
Diameter mm Diameter mm
Gas Ø 15.88 Gas Ø 12.70 Ø 15.88
Connection pipe Length Min/Max m 5/20 Connection pipe Length Min/Max m 5/30
Length(Pre-charge) m 15 Length(Pre-charge) m 15
Height difference Max m 15 Height difference Max m 20
Operation range Heating °C -25 to 35 Operation range Heating °C -20 to 35
*1:The values of heating capacity/input power/COP are based on measurement of EN14511 standard. Usage environment, such as operation of *1:The values of heating capacity/input power/COP are based on measurement of EN14511 standard. Usage environment, such as operation of
the heating equipment, room temperature, and controller adjustments, may cause disparities between practically determined values and the heating equipment, room temperature, and controller adjustments, may cause disparities between practically determined values and
these values. these values.
*2:All information of ErP can be available for downloaded from https://www.fujitsu-general.com/global/support/downloads/search/index.html *2:All information of ErP can be available for downloaded from https://www.fujitsu-general.com/global/support/downloads/search/index.html

Dimensions Dimensions
Outdoor Unit: Hydraulic Indoor Unit: Outdoor Unit: Hydraulic Indoor Unit:
Single Phase: WOHG112LHT/WOHG140LCTA 3 Phase: WOHK112LCTA/WOHK140LCTA/WOHK160LCTA Single Phase: WGHG140DG WOHA060LFCA/WOHA080LFCA WOHA100LFTA WGHA050DG/WGHA100DG
3 Phase: WGHK160DG
650 650 644 644
630 630
599 650 599

45.4
648 576 395 648 576
43 Drain port Ø20 43
400

400

352

320

400
Top view Top view
540 125
900 77 31 330 12 900 31 330 12 Top view Top view

AIR TO WATER
900 77 31 330 12

20 790 62 290
1850

1850
1840

1840
830
620
1290

1290

20

21
Side view Front view Side view
Front view Side view
21

21

698 103 698 103

Front view Side view Front view Side view Front view Side view Front view Side view

294 295

You might also like