You are on page 1of 1

www.frsky-rc.com www.frsky-rc.

com
Instruction Manual for FrSky L9R Receiver Range Check

Introduction A pre-flight range check should be done before each flying session. Reflections from nearby metal fences,
concrete buildings or trees can cause loss of signal both during range check and during the flight. Follow the steps
Thank you for purchasing FrSky L9R 9/12ch long range non-telemetry receiver. In order to fully enjoy the benefits below to perform the range check.
of this system, please read the instruction manual carefully and set up the device as described below.
1. Place the model at least 60cm (two feet) above non-metal contaminated ground (e.g. on a wooden bench).
Overview 2. The receiver antennas should be separated in the model, and do not touch the ground.
   3. The module antenna should be in a vertical position.
4. Turn on the transmitter and the receiver, press the F/S button on the XJT module for 4 seconds to enter range
Green LED Red LED Status
check mode, the RED LED will be off, GREEN LED will flash rapidly. The effective distance will be decreased to
ON Flashing Binding 1/30 (at least 30m).
ON OFF Normal 5. Walk away from the model while simultaneously operating the controls on the transmitter to confirm all
OFF Flashing Signal Lost controls’ normal operation.
Flash Twice OFF Failsafe set 6. Press the F/S button on the XJT module for 1~2 seconds to exit range check mode, RED LED will be back on,
indicating normal operation is back.
Specifications
Failsafe
Dimension: 46.25 x 26.6 x 14.2mm (L x W x H)
Weight: 19g
Antenna: PCB Antenna Failsafe is a useful feature in which all controls move to a preset position whenever the control signal is lost for a
Number of Channels: 1~9ch from conventional channel outputs, 1~12ch from SBUS port period of time. L9R receiver is support failsafe function for all channels. Follow the steps below to set failsafe
RSSI output: Analog RSSI output (0~3.3V) positions for each channel:
Operating Voltage Range: 4.0~10V
Operating Current: 100mA@5V 1. Bind the receiver first and turn on both the transmitter and the receiver;
Operating Range: about 2 times of the operating range for X-series receiver 2. Move the controls to the desired failsafe position for all channels;
Compatibility: FrSky X-series Module (XJT) etc. in LR12 mode (Switch 1 is OFF, Switch 2 is ON) 3. Press briefly the F/S button on the receiver (less than 1 second). The Green LED will flash twice, indicating
FrSky Taranis X9D etc. in LR12 mode the failsafe position has been set in the receiver.
L9R receiver is not work with FrSky V8, D8, and D16 Mode.
Features
To disable the failsafe function, re-bind the receiver.
·Longer operating range: 2 times of the operating range for X-series receiver
·More number of channels: 1~9ch from conventional channel outputs, 1~12ch from SBUS port Failsafe is recommended to set when system is firstly used, or receiver has been re-bound. Follow steps below
·With RSSI output to set failsafe.

Binding Procedure Option-1: How to set failsafe to a user-determined state on lost signal:
1) Bind the receiver to the transmitter module first and turn on both the transmitter and the receiver;
Binding is the process of uniquely associating a particular receiver to a transmitter module. A transmitter module 2) Move the controls to desired failsafe position for all channels;
can be bound to multiple receivers (not to be used simultaneously). A receiver can only be bound to one 3) Press briefly the F/S button on the receiver and you are done.
transmitter module.
Option-2: How to set failsafe for no pulses on lost signal:
Follow the steps below to finish the binding procedure: 1) Turn off the transmitter, power on the receiver, and then press briefly the F/S button on the receiver.
1. Turn on the transmitter while holding the F/S button on the XJT module (set to LR12 mode, Switch 1 is OFF
while Switch 2 is ON). Release the button. The RED LED on the XJT module will flash, indicating the transmitter is Note:
ready to bind to the receiver. If failsafe is not set, failsafe default will hold last position before signal is lost. In this case, there
2. Connect the battery to the receiver while holding the F/S button on the receiver. The RED LED on the receiver exists risk that your model will fly away or cause injury.
will flash, indicating the binding process is completed.
3. Turn off both the transmitter and the receiver. L9R Receiver is not support failsafe setting on Taranis X9D transmitter.
4. Turn on the transmitter and connect the battery.
The GREEN LED on the receiver indicates the receiver is receiving commands from the transmitter.

Note: After binding procedure is completed, recycle the power and check if the receiver is really
under control by linked transmitter.

The receiver/transmitter module binding will not have to be repeated, unless one of the two is
replaced
-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------
For more details, please check the complete manual for X6R from www.frsky-rc.com - Download – Manual. Should you have other
questions, please send e-mails to FrSky technical support sales4tech@gmail.com