* TEST REPORT IEC 61215: 2005 2nd Edition Crystalline ... 1 of 16 TRF
No. iec61215C rev.10 TEST REPORT IEC 61215: 2005 2nd Edition
Crystalline Silicon Terrestrial Photovoltaic (PV) Modules -

Pag 1 of 16

TRF No. iec61215C rev.10

TEST REPORT
IEC 61215: 2005 2nd Edition
Crystalline Silicon Terrestrial Photovoltaic (PV) Modules
- Design Qualification and Type Approval

Report Reference No. .................... :


PVQ01 19959-150035
Date of issue .................................. :
26 Mar 2015
Total number of pages .................. :
16
CB Testing Laboratory .................. :
Eurotest Laboratori S.r.l.
Address .......................................... :
Via Marconi, 23 – 35020 Brugine (PD) Italy
Applicant’s name ............................: WARIS SRL
Address .............................................: VIA SORINO, 2
38083 CONDINO TN , ITALY
Test specification ...........................:
Standard ...........................................:
IEC 61215: 2005 2nd Edition
Non-standard test method ................: N/A
Test Report Form No. ....................: iec61215C rev.10

This test report shall not be reproduced, except in full, without the written
approval of Eurotest Laboratori S.r.l.

Test item description ..................... :


Photovoltaic (PV) Module(s)
Trade Mark ....................................... :

Manufacturer ..................................... : Waris Srl


Model/Type reference ....................... : WRS250-ST60F
Ratings .............................................. : 260W, class A, 1000V
maximum system voltage
Page 2 of 16 Report Ref. No. PVQ01 19959-150035

TRF No. iec61215C rev.10

Testing procedure and testing location:


CB Testing Laboratory: Eurotest Laboratori S.r.l.
Testing location/ address .......................: Via Marconi, 23 – 35020
Brugine (PD) Italy

Associated CB Test Laboratory:

Testing location/ address .......................:

Tested by (name + signature) ..... :

Approved by (+ signature) ............ :

Testing procedure: TMP

Tested by (name + signature) ..... :

Approved by (+ signature) ............ :

Testing location/ address ........................... :

Testing procedure: WMT

Tested by (name + signature) ..... :

Witnessed by (+ signature) .......... :

Approved by (+ signature) ........... :

Testing location/ address .......................:

Testing procedure: SMT

Tested by (name + signature) ..... :

Approved by (+ signature) ............ :


Supervised by (+ signature) ........ :

Testing location/ address ................ :

Testing procedure: RMT

Tested by (name + signature) ..... :

Approved by (+ signature) ............ :

Supervised by (+ signature) ........ :

Testing location/ address .......................:

Firmato digitalmente da
Marco Maniero

Page 3 of 16 Report Ref. No. PVQ01 19959-150035

TRF No. iec61215C rev.10

Summary of testing:
Tests performed (name of test and test clause):
10.1 Visual inspection
10.2 Maximum power determination
10.3 Insulation test
10.15 Wet leakage current test – initial test
10.4 Measurement of temperature coefficients
10.5 Measurement of NOCT
10.6 Performance at STC and NOCT
10.7 Performance at low irradiance
10.8 Outdoor exposure test
10.9 Hot-spot endurance test
10.18 Bypass diode thermal test
10.10 UV preconditioning test
10.11 Thermal cycling test – 50 cycles
10.12 Humidity-freeze test
10.14 Robustness of terminations test
10.11 Thermal cycling test – 200 cycles
10.13 Damp-heat test
10.15 Wet leakage current test – intermediate test
10.16 Mechanical load test
10.17 Hail test
10.15 Wet leakage current test – final test
Testing location:
Eurotest Laboratori S.r.l.
Via Marconi, 23 – 35020 Brugine (PD)
Italy
Summary of compliance with National Differences: none
Copy of marking plate

Page 4 of 16 Report Ref. No. PVQ01 19959-150035


TRF No. iec61215C rev.10

GENERAL INFORMATION

Test item particulars:

Accessories and detachable parts included in the evaluation : none


Options
included .................................................................. :
none
Abbreviations used in the report:
HF – Humidity Freeze TC – Temperature Cycling
DH – Damp Heat Vmp – Maximum power voltage
Imp – Maximum power current Voc – Open circuit voltage
Isc - Short circuit current FF – Fill Factor
Pmp – Maximum power α – Current temperature coefficient
NOCT – Nominal Operating Cell Temperature β – Voltage temperature coefficient
STC – Standard Test Conditions δ – power temperature coefficient
Possible test case verdicts:
- test case does not apply to the test object ......................... :

N/A
- test not perfomed on customer request .............................. : N/P
- test object does meet the requirement ................................ : Pass
(P)
- test object does not meet the requirement .......................... : Fail (F)

Testing:

Date of receipt of test item.......................................................


: 25 Feb 2015
Date (s) of performance of tests .............................................. :
13 Mar 2015 ; 18 Mar 2015
General remarks:
The test results presented in this report relate only to the object tested.
Tests were requested by the customer.
Overall test result refers only to performed tests.
This report shall not be reproduced, except in full, without the written approval
of the Issuing testing
laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
Throughout this report a comma (point) is used as the decimal separator.
General product information:
Product Electrical Ratings:
Module type
WRS250-ST60F
Voc [V]
37.62
Vmp [V]
29.89
Imp [Adc]
8.36
Isc [Adc]
9.01
Pmp [W]
250
Maximum system
voltage [V]
1000
Series Fuse
Rating [A]
15
prev
next
out of 16

TEST REPORT IEC 61215: 2005 2nd Edition Crystalline ... 1 of 16 TRF
No. iec61215C rev.10 TEST REPORT IEC 61215: 2005 2nd Edition
Crystalline Silicon Terrestrial Photovoltaic (PV) Modules -

Download
<https://docslide.net/download/link/test-report-iec-61215-2005-2nd-edition-
crystalline-1-of-16-trf-no-iec61215c>Report
<https://docslide.net/report-copyright/test-report-iec-61215-2005-2nd-edition-
crystalline-1-of-16-trf-no-iec61215c/5af557147f8b9ae9488d58cb?t=TEST%20REPORT%20IEC
%2061215%3A%202005%202nd%20Edition%20Crystalline%20...%20%201%20of%2016%20TRF%20No.
%20iec61215C%20rev.10%20TEST%20REPORT%20IEC%2061215%3A%202005%202nd%20Edition
%20Crystalline%20Silicon%20Terrestrial%20Photovoltaic%20%28PV%29%20Modules%20-
&c=documents>

Published on
11-May-2018

View
217

Download
3

Facebook
<https://facebook.com/sharer/sharer.php?u=https://docslide.net/documents/test-
report-iec-61215-2005-2nd-edition-crystalline-1-of-16-trf-no-iec61215c.html>
Twitter
<https://twitter.com/intent/tweet/?text=TEST%20REPORT%20IEC%2061215:%202005%202nd
%20Edition%20Crystalline%20...%20%201%20of%2016%20TRF%20No.%20iec61215C
%20rev.10%20TEST%20REPORT%20IEC%2061215:%202005%202nd%20Edition%20Crystalline
%20Silicon%20Terrestrial%20Photovoltaic%20(PV)%20Modules%20-
&url=https://docslide.net/documents/test-report-iec-61215-2005-2nd-edition-
crystalline-1-of-16-trf-no-iec61215c.html>
E-Mail
<mailto:?subject=TEST REPORT IEC 61215: 2005 2nd Edition Crystalline
... 1 of 16 TRF No. iec61215C rev.10 TEST REPORT IEC 61215: 2005 2nd
Edition Crystalline Silicon Terrestrial Photovoltaic (PV) Modules
-&body=https://docslide.net/documents/test-report-iec-61215-2005-2nd-edition-
crystalline-1-of-16-trf-no-iec61215c.html>
LinkedIn
<https://www.linkedin.com/shareArticle?
mini=true&url=https://docslide.net/documents/test-report-iec-61215-2005-2nd-
edition-crystalline-1-of-16-trf-no-iec61215c.html&title=TEST%20REPORT%20IEC
%2061215:%202005%202nd%20Edition%20Crystalline%20...%20%201%20of%2016%20TRF%20No.
%20iec61215C%20rev.10%20TEST%20REPORT%20IEC%2061215:%202005%202nd%20Edition
%20Crystalline%20Silicon%20Terrestrial%20Photovoltaic%20(PV)%20Modules%20-
&source=https://docslide.net/documents/test-report-iec-61215-2005-2nd-edition-
crystalline-1-of-16-trf-no-iec61215c.html>

Transcript

Pag 1 of 16 TRF No. iec61215C rev.10 TEST REPORT IEC 61215: 2005 2nd
Edition Crystalline Silicon Terrestrial Photovoltaic (PV) Modules -
Design Qualification and Type Approval Report Reference No.
.................... : PVQ01 19959-150035 Date of issue
.................................. : 26 Mar 2015 Total number of pages
.................. : 16 CB Testing Laboratory .................. :
Eurotest Laboratori S.r.l. Address
.......................................... : Via Marconi, 23 35020
Brugine (PD) Italy Applicants name ............................: WARIS
SRL Address .............................................: VIA SORINO, 2
38083 CONDINO TN , ITALY Test specification ...........................:
Standard ...........................................: IEC 61215: 2005
2nd Edition Non-standard test method ................: N/A Test Report
Form No. ....................: iec61215C rev.10 This test report shall
not be reproduced, except in full, without the written approval of
Eurotest Laboratori S.r.l. Test item description ..................... :
Photovoltaic (PV) Module(s) Trade Mark
....................................... : Manufacturer
..................................... : Waris Srl Model/Type reference
....................... : WRS250-ST60F Ratings
.............................................. : 260W, class A, 1000V
maximum system voltage Page 2 of 16 Report Ref. No. PVQ01 19959-150035
TRF No. iec61215C rev.10 Testing procedure and testing location: CB
Testing Laboratory: Eurotest Laboratori S.r.l. Testing location/ address
.......................: Via Marconi, 23 35020 Brugine (PD) Italy
Associated CB Test Laboratory: Testing location/ address
.......................: Tested by (name + signature) ..... : Approved
by (+ signature) ............ : Testing procedure: TMP Tested by (name +
signature) ..... : Approved by (+ signature) ............ : Testing
location/ address ........................... : Testing procedure: WMT
Tested by (name + signature) ..... : Witnessed by (+ signature)
.......... : Approved by (+ signature) ........... : Testing location/
address .......................: Testing procedure: SMT Tested by (name
+ signature) ..... : Approved by (+ signature) ............ : Supervised
by (+ signature) ........ : Testing location/ address ................ :
Testing procedure: RMT Tested by (name + signature) ..... : Approved by
(+ signature) ............ : Supervised by (+ signature) ........ :
Testing location/ address .......................: Page 3 of 16 Report
Ref. No. PVQ01 19959-150035 TRF No. iec61215C rev.10 Summary of testing:
Tests performed (name of test and test clause): 10.1 Visual inspection
10.2 Maximum power determination 10.3 Insulation test 10.15 Wet leakage
current test initial test 10.4 Measurement of temperature coefficients
10.5 Measurement of NOCT 10.6 Performance at STC and NOCT 10.7
Performance at low irradiance 10.8 Outdoor exposure test 10.9 Hot-spot
endurance test 10.18 Bypass diode thermal test 10.10 UV preconditioning
test 10.11 Thermal cycling test 50 cycles 10.12 Humidity-freeze test
10.14 Robustness of terminations test 10.11 Thermal cycling test 200
cycles 10.13 Damp-heat test 10.15 Wet leakage current test intermediate
test 10.16 Mechanical load test 10.17 Hail test 10.15 Wet leakage
current test final test Testing location: Eurotest Laboratori S.r.l. Via
Marconi, 23 35020 Brugine (PD) Italy Summary of compliance with National
Differences: none Copy of marking plate Page 4 of 16 Report Ref. No.
PVQ01 19959-150035 TRF No. iec61215C rev.10 GENERAL INFORMATION Test
item particulars: Accessories and detachable parts included in the
evaluation : none Options included
.................................................................. :
none Abbreviations used in the report: HF Humidity Freeze TC Temperature
Cycling DH Damp Heat Vmp Maximum power voltage Imp Maximum power current
Voc Open circuit voltage Isc - Short circuit current FF Fill Factor Pmp
Maximum power Current temperature coefficient NOCT Nominal Operating
Cell Temperature Voltage temperature coefficient STC Standard Test
Conditions power temperature coefficient Possible test case verdicts: -
test case does not apply to the test object ......................... :
N/A - test not perfomed on customer request
.............................. : N/P - test object does meet the
requirement ................................ : Pass (P) - test object
does not meet the requirement .......................... : Fail (F)
Testing: Date of receipt of test
item....................................................... : 25 Feb
2015 Date (s) of performance of tests
.............................................. : 13 Mar 2015 ; 18 Mar
2015 General remarks: The test results presented in this report relate
only to the object tested. Tests were requested by the customer. Overall
test result refers only to performed tests. This report shall not be
reproduced, except in full, without the written approval of the Issuing
testing laboratory. "(see Enclosure #)" refers to additional information
appended to the report. "(see appended table)" refers to a table
appended to the report. Throughout this report a comma (point) is used
as the decimal separator. General product information: Product
Electrical Ratings: Module type WRS250-ST60F Voc [V] 37.62 Vmp [V] 29.89
Imp [Adc] 8.36 Isc [Adc] 9.01 Pmp [W] 250 Maximum system voltage [V]
1000 Series Fuse Rating [A] 15 Page 5 of 16 Report Ref. No. PVQ01
19959-150035 TRF No. iec61215C rev.10 Description of module construction
as declared by the applicant: (Manufactories and part numbers, unless
otherwise specified) Sample
............................................. : Random sampling from
production not dependent on laboratoryPrototype submitted by client
Module Front Cover ...................................... : Glass /
Mistlite / San Marco Spa / 3.2mm Rear Cover
...................................... : Polymeric / PVS190 / Filmcutter
Srl Encapsulation material .................... : EVA / Conserv A360-10
UC / Renewsys Frame .............................................. :
Aluminium / Marioli / Marioli Srl Dimensions (l x w x h) [mm]
............ : 1650 x 992 x 38 Module area [m]
.............................. : 1.64 Adhesives (frame)
............................ : Silicon / PV 804 / Dow corning Minimum
distance between current-carrying parts and module edge [mm] 15.4 Cell
Cell (include type) ............................ : Poly-Si Cells (l x w)
[mm] ............................. : 156 x 156 Cell thickness [m]
.......................... : 200 Cell area [cm]
................................. : 243.36 Number of cells
................................ : 60 Components and other Cells per
bypass diode .................... : 20 Type of bypass
diode....................... : Not declared No. of bypass diodes
...................... : Not declared Cell- and string connectors
.............. : Between cells: Schlenk Matallfollien GmbH / Sn62Pb36Ag2
/ 2.00 x 0.15 mm Between strings: Schlenk Matallfollien GmbH /
Sn62Pb36Ag2 / 5.00 x 0.40 mm Junction box
..................................... : Not declared
Cable................................................ : Not declared
Connectors ...................................... : Not declared
Adhesives (junction box ) ................ : Silicon / PV 804 / Dow
corning Potting material (junction box) ......... : N/A Others
.............................................. : see Description of the
sample (photos) at the end of the report for major details Page 6 of 16
Report Ref. No. PVQ01 19959-150035 TRF No. iec61215C rev.10 Testing
procedure New module type Modifications (if yes, please choose the
applicable modification according to the IECEE Retesting Guideline
DSH0647A) Change in cell technology Modification to encapsulation system
Modification to superstrate Increase in module size Modification to
backsheet/ substrate Modification to frame and/ or mounting structure
Modification to junction box/ electrical termination Change in cell
interconnect materials or technique Change in electrical circuit of an
identical package Higher or lower power output (by 10%) in the identical
package including size and using the identical cell process
Qualification of a frameless module after the design has received
certification as a framed module Change in bypass diode or number of
diodes Other: 10.1 Visual inspection 10.2 Maximum power determination
10.3 Insulation test 10.15 Wet leakage current test initial test 10.16
Mechanical load test 10.15 Wet leakage current test final test Original
Test Report Ref. No : - Module group assignment: Sample # Model (module
type) Sample S/N 01 WRS250-ST60F WRSP60C0111268524 08 WRS250-ST60F
WRSP60C0111268525 Supplementary info: none Page 7 of 16 Report Ref. No.
PVQ01 19959-150035 IEC 61215 Clause Requirement + Test Result - Remark
Verdict TRF No. iec61215C rev.10 4 MARKING Name, monogram or symbol of
manufacturer ...... : Type or model number
........................................... : WRS250-ST60F Serial number
......................................................... : Laminated
Polarity of terminals or leads ................................. : On
connectors Maximum system voltage ......................................
: 1000 The date and place of manufacture ....................... :
Traceable by serial number Initial examination All modules P 10
Preconditioning ..................................................... :
5.3 kWh/m 10.1 Visual inspection
................................................... : See table 10.1 Int
P 10.2 Maximum power determination ............................ : See
table 10.2 Int 10.3 Insulation test
........................................................ : See table
10.3 Int P 10.15 Wet leakage current test See table 10.15 Int P Group A
Control Module Sample Group ID A Group E1 1 Module Sample Group ID E1 P
10.16 Mechanical load test .............................................
: 2400 ; 8000 Pa 10.16.4 -No open-circuits or ground faults detected P
Final measurements See table 10.16 E1 P 10.16 Mechanical load test
............................................. : 10000 Pa 10.16.4 -No
open-circuits or ground faults detected P Final measurements See table
10.16 E1 P Final measurement All modules P 10.15 Wet leakage current
test See table 10.15 F Page 8 of 16 Report Ref. No. PVQ01 19959-150035
IEC 61215 Clause Requirement + Test Result - Remark Verdict TRF No.
iec61215C rev.10 10.1 Intitial TABLE: Visual inspection (Initial) P Test
Date (MM/DD/YYYY) ........................... : 13 Mar 2015, Sample 01
13 Mar 2015, Sample 08 Sample # Nature and position of initial findings
comments or attach photos Verdict 01 No major visual defects P 08 No
major visual defects P Supplementary information: none Sample Technician
Amb. Temp. [C] Rel. Hum. [%] 01 08 Marco Maniero Marco Maniero 24.5 24.3
37.8 38.0 10.2 Initial TABLE: Maximum power determination (initial) Test
Date [MM/DD/YYYY] ....................... : 13 Mar 2015, Sample 01 13
Mar 2015, Sample 08 Module temperature [C] .......................... :
25.0 Irradiance [W/m2] ..................................... : 1000
Sample # Voc [V] Vmp [V] Isc [A] Imp [A] Pmp [W] FF [%] 01 37.64 30.22
8.85 8.24 249.02 75.7 08 37.60 30.10 8.85 8.26 248.51 74.7 Supplementary
information: none Sample Technician Amb. Temp. [C] Rel. Hum. [%] 01 08
Marco Maniero Marco Maniero 24.7 24.8 35.6 35.9 Page 9 of 16 Report Ref.
No. PVQ01 19959-150035 IEC 61215 Clause Requirement + Test Result -
Remark Verdict TRF No. iec61215C rev.10 10.3 Initial Table: Insulation
test (initial) P Test Date [MM/DD/YYYY] ....................... : 13 Mar
2015, Sample 01 13 Mar 2015, Sample 08 Test Voltage applied [V]
.......................... : 6000 ; 3000 ; 1000 Sample # Measured
Required Dielectric breakdown Result M M Yes (description) No 01 >1000
24.5 P 08 >1000 24.5 P Supplementary information: Size of module [m]:
1.63 Sample Technician Amb. Temp. [C] Rel. Hum. [%] 01 08 Marco Maniero
Marco Maniero 24.5 24.6 37.6 37.2 10.15 Initial TABLE: Wet leakage
current test (Initial) P Test Date [MM/DD/YYYY]
................................. : 16 Mar 2015, Sample 01 16 Mar 2015,
Sample 08 Test Voltage applied [V] ....................................
: 1000 Solution resistivity [ cm]
....................................... : < 3,500 cm at 22 3C 2127
Solution temperature [C] .................................... : 22.0
Sample # Measured [M] Limit [M] Result 01 734 24.5 P 08 768 24.5 P
Supplementary information: Size of module [m]: 1.63 Sample Technician
Amb. Temp. [C] Rel. Hum. [%] 01 08 Marco Maniero Marco Maniero 21.5 21.6
39.2 39.0 Page 10 of 16 Report Ref. No. PVQ01 19959-150035 IEC 61215
Clause Requirement + Test Result - Remark Verdict TRF No. iec61215C
rev.10 10.16 E1 TABLE: Mechanical load test P Sample #
....................................................... : 08 Test Date
[MM/DD/YYYY] .............................. : 16 Mar 2015- 17 Mar 2015
Mounting method ........................................... :Two
horizontal bars fixed on the long side with clamp 100mm at a distance of
350 mm from the edge of the module Two horizontal bars fixed on the long
side with clamp 100mm at a distance of 350 mm from the edge of the
module Load applied to .............................................. :
front side back side Mechanical load [Pa]
..................................... : 2400 / 8000 2400 First cycle
time (start/end) ............................ : 10:12 / 11:12 11:49 /
12:49 Intermittent open-circuit (yes/no) ................... : no no P
Second cycle time (start/end) ....................... : 14:19 / 15:19
15:41 / 16:41 Intermittent open-circuit (yes/no) ................... :
no no P Third cycle time (start/end) ........................... : 10:06
/ 11:06 12:00 / 13:00 Intermittent open-circuit (yes/no)
................... : no no P Supplementary information: Maximum bending
at module center: 42 mm Technician Ambient temperature [C] Relative
humidity [%] Marco Maniero 22.7 46.7 (10.1 Visual inspection after
mechanical load test) Test Date [MM/DD/YYYY]
............................ : 17 Mar 2015 Sample # Nature and position
of initial findings comments or attach photos 08 No major visual defects
P Supplementary information: none Technician Ambient temperature [C]
Relative humidity [%] Marco Maniero 23.0 45.1 (10.2 Maximum power
determination after mechanical load test) Test Date [MM/DD/YYYY]
............................ : 18 Mar 2015 Module temperature [C]
............................... : 25.0 Irradiance [W/m2]
........................................... : 1000 Sample # Voc [V] Vmp
[V] Isc [A] Imp [A] Pmp [W] FF [%] 08 37.50 29.69 8.84 8.15 241.98 73.0
Pmp degradation after this test [%] 5% ......................... : 2.63
P Supplementary information: none Technician Ambient temperature [C]
Relative humidity [%] Marco Maniero 23.5 38.7 Page 11 of 16 Report Ref.
No. PVQ01 19959-150035 IEC 61215 Clause Requirement + Test Result -
Remark Verdict TRF No. iec61215C rev.10 (10.3 Insulation test after
mechanical load test) Test Date [MM/DD/YYYY] ....................... :
18 Mar 2015 Test Voltage applied [V] .......................... : 6000 ;
3000 ; 1000 Sample # Measured Required Dielectric breakdown Result M M
Yes (description) No 08 >1000 24.5 P Supplementary information: none
Technician Ambient temperature [C] Relative humidity [%] Marco Maniero
23.1 45.8 10.16 E1 TABLE: Mechanical load test P Sample #
....................................................... : 08 Test Date
[MM/DD/YYYY] .............................. : 18 Mar 2015 Mounting
method ........................................... :Two horizontal bars
fixed on the long side with clamp 100mm at a distance of 350 mm from the
edge of the module Load applied to
.............................................. : front side Mechanical
load [Pa] ..................................... : 10000 First cycle time
(start/end) ............................ : 14:39 / 15:49 Intermittent
open-circuit (yes/no) ................... : no P Supplementary
information: Maximum bending at module center: 45 mm Technician Ambient
temperature [C] Relative humidity [%] Marco Maniero 23.6 37.8 (10.1
Visual inspection after mechanical load test) Test Date [MM/DD/YYYY]
............................ : 18 Mar 2015 Sample # Nature and position
of initial findings comments or attach photos 08 No major visual defects
P Supplementary information: none Technician Ambient temperature [C]
Relative humidity [%] Marco Maniero 23.8 39.9 Page 12 of 16 Report Ref.
No. PVQ01 19959-150035 IEC 61215 Clause Requirement + Test Result -
Remark Verdict TRF No. iec61215C rev.10 (10.2 Maximum power
determination after mechanical load test) Test Date [MM/DD/YYYY]
............................ : 18 Mar 2015 Module temperature [C]
............................... : 25.0 Irradiance [W/m2]
........................................... : 1000 Sample # Voc [V] Vmp
[V] Isc [A] Imp [A] Pmp [W] FF [%] 08 37.48 29.54 8.83 8.15 240.73 72.7
Pmp degradation after this test [%] 5% ......................... : 0.52
P Supplementary information: Degradation is calculated from the
mechanical load to 8000 Pa Technician Ambient temperature [C] Relative
humidity [%] Marco Maniero 23.9 40.5 (10.3 Insulation test after
mechanical load test) Test Date [MM/DD/YYYY] ....................... :
18 Mar 2015 Test Voltage applied [V] .......................... : 6000 ;
3000 ; 1000 Sample # Measured Required Dielectric breakdown Result M M
Yes (description) No 08 >1000 24.5 P Supplementary information: none
Technician Ambient temperature [C] Relative humidity [%] Marco Maniero
23.8 40.2 Page 13 of 16 Report Ref. No. PVQ01 19959-150035 IEC 61215
Clause Requirement + Test Result - Remark Verdict TRF No. iec61215C
rev.10 10.2 F TABLE: Maximum power determination (final) P Test Date
[MM/DD/YYYY] ....................... : 18 Mar 2015, Sample 01 18 Feb
2015, Sample 08 Module temperature [C] .......................... : 25.0
Irradiance [W/m2] ...................................... : 1000 Sample #
Voc [V] Vmp [V] Isc [A] Imp [A] FF [%] Pmp [W] Degradation [%] Limit [%]
01 37.73 30.18 8.85 8.24 74.5 248.73 0.12 -8 08 37.48 29.54 8.83 8.15
72.7 240.73 3.13 -8 Supplementary information: none Sample Technician
Amb. Temp. [C] Rel. Hum. [%] 01 08 Marco Maniero Marco Maniero 23.6 23.9
37.7 40.2 10.15 F TABLE: Wet leakage current test (final) P Test Date
[MM/DD/YYYY] ................................. : 18 Mar 2015, Sample 01
18 Mar 2015, Sample 08 Test Voltage applied [V]
................................... : 1000 Solution resistivity [
cm]....................................... : < 3,500 cm at 22 3C 2500
Solution temperature [C] .................................... : 22.6
Sample # Measured [M] Limit [M] Result 01 794 24.5 P 08 836 24.5 P
Supplementary information: Size of module [m]: 1.63 Sample Technician
Amb. Temp. [C] Rel. Hum. [%] 01 08 Marco Maniero Marco Maniero 24.5 24.5
38.8 39.1 Page 14 of 16 Report Ref. No. PVQ01 19959-150035 TRF No.
iec61215C rev.10 List of Annexes ANNEX 01 PVQ-PS2 R1.20 : List of
measurement equipment ANNEX 03 PVQ-PS2 R1.17 : Statement of the
estimated uncertainty of the test results Page 15 of 16 Report Ref. No.
PVQ01 19959-150035 TRF No. iec61215C rev.10 Description of the sample
(photos) Fig. 01 Front Fig. 02 Back Fig. 03 Junction Box Fig. 04
Junction Box (internal) Page 16 of 16 Report Ref. No. PVQ01 19959-150035
TRF No. iec61215C rev.10 Fig. 05 Cable Fig.06 Connector Fig. 07 Frame
detail ----------------- End of TRF No. PVQ01
19959-150035------------------
2015-03-
26T08:29:26+0000MNRMRC88E29G693B/700000082319503.JwtyW5e+qmDtmKlHuG2/XcVHQbU=2015-
03-26T14:09:25+0100ROVEGGIO
FILIPPO

Recommended

INTERNATIONAL IEC STANDARD 61215 - olino. ?· International Standard IEC


61215 has been prepared by IEC technical committee 82: Solar
photovoltaic energy systems. This second edition cancels and replaces
thew ...
<https://docslide.net/documents/international-iec-standard-61215-
olinoorgwwwolinoorgwp-contentuploads201205iec61215pdfpdf.html>
INTERNATIONAL IEC STANDARD 61215 - olino. ?· International Standard IEC
61215 has been prepared by IEC technical committee 82: Solar
photovoltaic energy systems. This second edition cancels and replaces
thew ...
<https://docslide.net/documents/international-iec-standard-61215-
olinoorgwwwolinoorgwp-contentuploads201205iec61215pdfpdf.html>Documents
<https://docslide.net/category/documents.html>
PHOTOVOLTAIC MODULES MAGE POwERTEC PLUS ?· 45 iso 9001, iec 61215, iec
61730 ˜˚˛˛ ˝˝˙ ˙ x ˜˙˛…
<https://docslide.net/documents/photovoltaic-modules-mage-powertec-plus-45-iso-
9001-iec-61215-iec-61730-.html>
PHOTOVOLTAIC MODULES MAGE POwERTEC PLUS ?· 45 iso 9001, iec 61215, iec
61730 ˜˚˛˛ ˝˝˙ ˙ x ˜˙˛…
<https://docslide.net/documents/photovoltaic-modules-mage-powertec-plus-45-iso-
9001-iec-61215-iec-61730-.html>Documents
<https://docslide.net/category/documents.html>
Product or Process Modifications Requiring Limited CBTL ... 61215:1993
Ed. 1.0 and IEC 61215:2005 Ed. 2.0 Crystalline silicon terrestrial
photovoltaic (PV) modules - Design qualification and type approval.
<https://docslide.net/documents/product-or-process-modifications-requiring-
limited-cbtl-612151993-ed-10-and.html>
Product or Process Modifications Requiring Limited CBTL ... 61215:1993
Ed. 1.0 and IEC 61215:2005 Ed. 2.0 Crystalline silicon terrestrial
photovoltaic (PV) modules - Design qualification and type approval.
<https://docslide.net/documents/product-or-process-modifications-requiring-limited-
cbtl-612151993-ed-10-and.html>Documents
<https://docslide.net/category/documents.html>
IEC 61215:2005 IEC 61646:2008 - tuv.com ??wurde eine zweite Edition
dieses Standards, IEC 61646 „Terrestrische Dnnschicht-Photo-voltaik-
(PV) Module – Bauarteignung und Bauartzulassung“, ...
<https://docslide.net/documents/iec-612152005-iec-616462008-tuvcom-wurde-eine-
zweite-edition-dieses-standards.html>
IEC 61215:2005 IEC 61646:2008 - tuv.com ??wurde eine zweite Edition
dieses Standards, IEC 61646 „Terrestrische Dnnschicht-Photo-voltaik-
(PV) Module – Bauarteignung und Bauartzulassung“, ...
<https://docslide.net/documents/iec-612152005-iec-616462008-tuvcom-wurde-eine-
zweite-edition-dieses-standards.html>Documents
<https://docslide.net/category/documents.html>
Product Certification Application Form - iecee.org 61215:1993 Ed. 1.0
(and Ed. 2.0 - proposed) Crystalline silicon terrestrial photovoltaic
(PV) modules - Design qualification and type approval
<https://docslide.net/documents/product-certification-application-form-ieceeorg-
612151993-ed-10-and-ed-20.html>
Product Certification Application Form - iecee.org 61215:1993 Ed. 1.0
(and Ed. 2.0 - proposed) Crystalline silicon terrestrial photovoltaic
(PV) modules - Design qualification and type approval
<https://docslide.net/documents/product-certification-application-form-ieceeorg-
612151993-ed-10-and-ed-20.html>Documents
<https://docslide.net/category/documents.html>
NORME CEI INTERNATIONALE IEC ... - cdn. INTERNATIONALE CEI IEC
INTERNATIONAL STANDARD 61215 Deuxime dition Second edition 2005-04
Modules photovoltaques (PV) au silicium cristallin pour ...
<https://docslide.net/documents/norme-cei-internationale-iec-cdn-internationale-
cei-iec-international-standard.html>
NORME CEI INTERNATIONALE IEC ... - cdn. INTERNATIONALE CEI IEC
INTERNATIONAL STANDARD 61215 Deuxime dition Second edition 2005-04
Modules photovoltaques (PV) au silicium cristallin pour ...
<https://docslide.net/documents/norme-cei-internationale-iec-cdn-internationale-
cei-iec-international-standard.html>Documents
<https://docslide.net/category/documents.html>
TEST REPORT IEC 60601-1 / EN 60601 -1 Medical electrical ...docs- ?·
page 4 of 38 Report No. ETS-060065 IEC 60601+ Am. 1 & 2 Clause
Requirement + Test Result - Remark Verdict TRF No. I6011__C TRF
originator: UL
<https://docslide.net/documents/test-report-iec-60601-1-en-60601-1-medical-
electrical-docs-europeelectrocomponentscomwebdocs0ddcpdf.html>
TEST REPORT IEC 60601-1 / EN 60601 -1 Medical electrical ...docs- ?·
page 4 of 38 Report No. ETS-060065 IEC 60601+ Am. 1 & 2 Clause
Requirement + Test Result - Remark Verdict TRF No. I6011__C TRF
originator: UL
<https://docslide.net/documents/test-report-iec-60601-1-en-60601-1-medical-
electrical-docs-europeelectrocomponentscomwebdocs0ddcpdf.html>Documents
<https://docslide.net/category/documents.html>
IEC 60601-1:2005 3rd Edition
<https://docslide.net/documents/iec-60601-12005-3rd-edition.html>
IEC 60601-1:2005 3rd Edition
<https://docslide.net/documents/iec-60601-12005-3rd-edition.html>Documents
<https://docslide.net/category/documents.html>
??have been qualified according to IEC 61215, IEC 61730-1 and IEC
61730-2 ... The basis for this Safety Class Il test procedure is IEC
60664-1:2007
<https://docslide.net/documents/have-been-qualified-according-to-iec-61215-iec-
61730-1-and-iec-61730-2-the.html>
??have been qualified according to IEC 61215, IEC 61730-1 and IEC
61730-2 ... The basis for this Safety Class Il test procedure is IEC
60664-1:2007
<https://docslide.net/documents/have-been-qualified-according-to-iec-61215-iec-
61730-1-and-iec-61730-2-the.html>Documents
<https://docslide.net/category/documents.html>
315W 310W - LG 61215, IEC 61730-1/-2 IEC 61701 (Salt mist corrosion
test) IEC 62716 (Ammonia corrosion test) ISO 9001 ... * 1) 1st year:
98%, 2) After 1st year: ...
<https://docslide.net/documents/315w-310w-lg-61215-iec-61730-1-2-iec-61701-salt-
mist-corrosion-test-iec-62716.html>
315W 310W - LG 61215, IEC 61730-1/-2 IEC 61701 (Salt mist corrosion
test) IEC 62716 (Ammonia corrosion test) ISO 9001 ... * 1) 1st year:
98%, 2) After 1st year: ...
<https://docslide.net/documents/315w-310w-lg-61215-iec-61730-1-2-iec-61701-salt-
mist-corrosion-test-iec-62716.html>Documents
<https://docslide.net/category/documents.html>
The Thresher Test Crystalline Silicon Terrestrial ... ??7/19/2011 Page 1
“The Thresher Test” Crystalline Silicon Terrestrial Photovoltaic (PV)
Modules Long Term Reliability and Degradation International PV Quality Forum
<https://docslide.net/documents/the-thresher-test-crystalline-silicon-terrestrial-
7192011-page-1-the.html>
The Thresher Test Crystalline Silicon Terrestrial ... ??7/19/2011 Page 1
“The Thresher Test” Crystalline Silicon Terrestrial Photovoltaic (PV)
Modules Long Term Reliability and Degradation International PV Quality
Forum
<https://docslide.net/documents/the-thresher-test-crystalline-silicon-terrestrial-
7192011-page-1-the.html>Documents
<https://docslide.net/category/documents.html>
IEC 61201 Draft 2nd Edition
<https://docslide.net/documents/iec-61201-draft-2nd-edition.html>
IEC 61201 Draft 2nd Edition
<https://docslide.net/documents/iec-61201-draft-2nd-edition.html>Documents
<https://docslide.net/category/documents.html>
IEC 61730 2ND EDITION - UL Library 61730 2ND EDITION. page 2 ... IEC
61215 Standards. For example, ... Insulation coordination is a method to
proactively structure
<https://docslide.net/documents/iec-61730-2nd-edition-ul-library-61730-2nd-
edition-page-2-iec-61215-standards.html>
IEC 61730 2ND EDITION - UL Library 61730 2ND EDITION. page 2 ... IEC
61215 Standards. For example, ... Insulation coordination is a method to
proactively structure
<https://docslide.net/documents/iec-61730-2nd-edition-ul-library-61730-2nd-edition-
page-2-iec-61215-standards.html>Documents
<https://docslide.net/category/documents.html>
10.6 Schedule of Accreditationgcc- Schedule of Accreditation Issue No:
3/ Issue Date: ... Module 10.1: Visual inspection CEI EN 61215:2006
10.1, IEC 61215:2005 10.1
<https://docslide.net/documents/106-schedule-of-accreditationgcc-schedule-of-
accreditation-issue-no-3-issue.html>
10.6 Schedule of Accreditationgcc- Schedule of Accreditation Issue No:
3/ Issue Date: ... Module 10.1: Visual inspection CEI EN 61215:2006
10.1, IEC 61215:2005 10.1
<https://docslide.net/documents/106-schedule-of-accreditationgcc-schedule-of-
accreditation-issue-no-3-issue.html>Documents
<https://docslide.net/category/documents.html>
VALUTAZIONE RISCHIO INCENDIO ALLEGATO B ?· Test IEC 61215:
Certificazione della qualità e delle caratteristiche…
<https://docslide.net/documents/valutazione-rischio-incendio-allegato-b-test-iec-
61215-certificazione-della.html>
VALUTAZIONE RISCHIO INCENDIO ALLEGATO B ?· Test IEC 61215:
Certificazione della qualità e delle caratteristiche…
<https://docslide.net/documents/valutazione-rischio-incendio-allegato-b-test-iec-
61215-certificazione-della.html>Documents
<https://docslide.net/category/documents.html>
KMBT 754-20150417112724 - Certificate for IEC61215_Dec.30,2015...p. R.
China Basis: IEC 61215:2005 EN 61215:2005 Crystalline silicon
terrestrial ... JKMxxxM-72 (xxx=250-335, in steps of 5, 72 cells)
JKMxxxM-72-J ...
<https://docslide.net/documents/kmbt-754-20150417112724-certificate-for-
iec61215dec302015p-r-china-basis.html>
KMBT 754-20150417112724 - Certificate for IEC61215_Dec.30,2015...p. R.
China Basis: IEC 61215:2005 EN 61215:2005 Crystalline silicon
terrestrial ... JKMxxxM-72 (xxx=250-335, in steps of 5, 72 cells)
JKMxxxM-72-J ...
<https://docslide.net/documents/kmbt-754-20150417112724-certificate-for-
iec61215dec302015p-r-china-basis.html>Documents
<https://docslide.net/category/documents.html>
CWeb viewIEC 61215 มอก. 1843(Crystalline Silicon Performance) ... IEC
60364-7-712 มอก. 2572-2555 อออนๆ (โปรดระบบ )
<https://docslide.net/documents/cweb-viewiec-61215-1843crystalline-silicon-
performance-iec-60364-7-712.html>
CWeb viewIEC 61215 มอก. 1843(Crystalline Silicon Performance) ... IEC
60364-7-712 มอก. 2572-2555 อออนๆ (โปรดระบบ )
<https://docslide.net/documents/cweb-viewiec-61215-1843crystalline-silicon-
performance-iec-60364-7-712.html>Documents
<https://docslide.net/category/documents.html>
TEST REPORT Report Reference No: Testing Report-2XX and 3XX...TRF No.:
IEC 61010_C TRF originator: VDE TEST REPORT IEC 61010-1/ EN 61010-1
Safety requirements for electrical equipment for
<https://docslide.net/documents/test-report-report-reference-no-testing-report-
2xx-and-3xxtrf-no-iec-61010c.html>
TEST REPORT Report Reference No: Testing Report-2XX and 3XX...TRF No.:
IEC 61010_C TRF originator: VDE TEST REPORT IEC 61010-1/ EN 61010-1
Safety requirements for electrical equipment for
<https://docslide.net/documents/test-report-report-reference-no-testing-report-2xx-
and-3xxtrf-no-iec-61010c.html>Documents
<https://docslide.net/category/documents.html>
Crystalline Silicon Terrestrial Photovoltaic ?· Crystalline Silicon
Terrestrial Photovoltaic Cells…
<https://docslide.net/documents/crystalline-silicon-terrestrial-photovoltaic-
crystalline-silicon-terrestrial.html>
Crystalline Silicon Terrestrial Photovoltaic ?· Crystalline Silicon
Terrestrial Photovoltaic Cells…
<https://docslide.net/documents/crystalline-silicon-terrestrial-photovoltaic-
crystalline-silicon-terrestrial.html>Documents
<https://docslide.net/category/documents.html>
Test Report Form : IEC 61439-6 Edition 1 Report Form : IEC 61439-6
Edition 1.0c Document date : 2014-10-07 Test Object : Power switchgear
and controlgear Busbar Trunking Systems
<https://docslide.net/documents/test-report-form-iec-61439-6-edition-1-report-
form-iec-61439-6-edition-10c.html>
Test Report Form : IEC 61439-6 Edition 1 Report Form : IEC 61439-6
Edition 1.0c Document date : 2014-10-07 Test Object : Power switchgear
and controlgear Busbar Trunking Systems
<https://docslide.net/documents/test-report-form-iec-61439-6-edition-1-report-form-
iec-61439-6-edition-10c.html>Documents
<https://docslide.net/category/documents.html>
View more >
<https://docslide.net/search?
q=TEST+REPORT+IEC+61215%3A+2005+2nd+Edition+Crystalline+...++1+of+16+TRF+No.
+iec61215C+rev.10+TEST+REPORT+IEC+61215%3A+2005+2nd+Edition+Crystalline+Silicon+Ter
restrial+Photovoltaic+%28PV%29+Modules+-&u=1>

* About Us <https://docslide.net/about.html>
* Contact <https://docslide.net/contacts.html>
* Term <https://docslide.net/info/terms.html>
* DMCA <https://docslide.net/info/dmca.html>
* Cookie Policy <https://docslide.net/cookie-policy.html>

------------------------------------------------------------------------

STARTUP - SHARE TO SUCCESS


x <javascript:void(0);>
By using our site you agree to our Cookie policy
<https://docslide.net/cookie-policy.html>. That's Fine
<javascript:void(0);>

You might also like