TECHANICAL DATA SHEET FOR PASSENGER ELEVATOR

SR.
PARTICULARS TENDER SPECS UNITS VENDOR CONFIRMATION
NO.

A GENERAL INFORMATION
1 MAKE As per tender specs
2 Model Vendor To Specify
3 TYPE (MR / MRL / Mini MR) Vendor To Specify
4 CAPACITY- (No. of passengers) 10 NOS.
5 CAPACITY- (KG) Vendor To Specify KGS
6 REQUIRED CLEAR DOOR OPENING WIDTH 900 MM
7 REQUIRED DOOR OPENING CLEAR HEIGHT 2100 MM
8 AVAILABLE SHAFT WIDTH AS PER ENCLOSED DRAWING MM
9 AVAILABLE SHAFT DEPTH AS PER ENCLOSED DRAWING MM
10 REQUIRED CAR INSIDE WIDTH Vendor To Specify MM
11 REQUIRED CAR INSIDE DEPTH Vendor To Specify MM
12 REQUIRED CAR INSIDE HEIGHT Vendor To Specify MM
14 CAR AND HOIST WAY ENTRANCE 2 PANEL AUTOMATIC CENTRE OPENING
15 CAR DOOR OPENING TIME 2 - 4 SEC (ADJUSTABLE) SECONDS
16 CAR DOOR CLOSING TIME 2 - 4 SEC (ADJUSTABLE) SECONDS
17 MACHINE LOCATION Vendor To Specify
18 CLEAR MACHINE ROOM HEIGHT Vendor To Specify METERS
19 VERTICAL RISE AS PER ENCLOSED DRAWING METRE
20 BASEMENT TO GF HEIGHT AS PER ENCLOSED DRAWING M
21 GF TO FIRST FLOOR HEIGHT AS PER ENCLOSED DRAWING M
22 REST FLOOR TO FLOOR HEIGHT AS PER ENCLOSED DRAWING M
23 SPEED 1.0 MPS MPM
24 STOPS AS PER ENCLOSED DRAWING NOS.
25 NOS OF FLOOR SERVING AS PER ENCLOSED DRAWING
26 OPENINGS AS PER ENCLOSED DRAWING NOS.
27 INSTALLATION INDOOR
28 QTY AS PER BOQ NOS

ASTHETIC FINISH / MATERAIL OF


B
CONSTRUCTION
SS HAIR LINE FINISH 304 WITH 1.2MM
1 CAR DESIGN
THICKNESS
SS HAIR LINE FINISH 304 WITH 1.2MM
2 CAR ENCLOSURE
THICKNESS
SS HAIR LINE FINISH 304 WITH 1.2MM
3 CAR DOOR
THICKNESS
25MM RECESS TO BE PROVIDED
4 FLOORING
25mm thick granite 65 kg / m2 (by others)
5 CAR SILL EXTRUDED HARD ALUMINIUM
6 HANDRAIL SS HAIR LINE FINISH ONLY ON BACK SIDE
SS HAIR LINE FINISH 304 WITH 1.2MM
7 LANDING DOOR
THICKNESS
SS HAIR LINE FINISH 304 WITH 1.2MM
8 CAR OPERATING PANEL
THICKNESS
HALL BUTTON WITH RED BACKGROUND
9 SS HAIR LINE FINISH
LIGHT & BRAILLE MARKING
10 MIRROR ON REAR WALL REQUIRED
DOT MATRIX / 16 SEGMENT DIGITAL
11 DISPLAY IN MAIN LOBBY
POSITION INDICATOR
BACKGROUND MUSIC INSIDE THE
12 NOT REQUIRED
ELEVATOR
DIGITAL CAR POSITION INDICATOR IN CAR
13 REQUIRED
AND ALL LANDING

14 ARRIVAL GONG ON CAR AND ALL LANDING' REQUIRED

CAR LANDING AND PRE ANNOUNCING


INDICATINS
15 REQUIRED
a) Voice synthesizer, car top chime and car
position and direction (scrolling) indicator.

16 HALL BUTTON WITH BRAILLE MARKING SELF ILLUMINATING (MICRO PUSH)


i) HOME LANDING UP INDICATION
ii) INTERMEDIATE UP & DOWN
iii) TERMINAL LANDING DOWN INDICATION

C ELEVATOR CAR
1 CEILING /LIGHTING AS APPROVED BY ARCHITECT
LED LIGHTS IN LIFT
2 REQUIRED
(Indirect Diffused Lighting)
3 AIRCONDITIONED NOT REQUIRED
SOUND FREE AXIAL FLOW FAN FITTED
4 VENTILATION FAN
ABOVE & HIDDEN BY FALSE CEILING.
5 EMERGENCY EXIT IN ROOF Vendor To Specify
6 NOISE REDUCTION KIT As per tender specs
FULL LENGTH CRISS CROSS INFRARED
7 PROTECTIVE CURTAIN
BEAMS
9 OKR MAINTENANCE LIGHT Vendor To Specify
10 OKR POWER SOCKET Vendor To Specify

REQUIRED 1 NOS. COP ON EITHER SIDES


11 CAR OPERATING PANEL OF THE DOOR WITH TRANSOMS ON CAR
TOP (INSIDE THE ELEVATOR)
TECHANICAL DATA SHEET FOR PASSENGER ELEVATOR
SR.
PARTICULARS TENDER SPECS UNITS VENDOR CONFIRMATION
NO.

D TRANSMITION
VVVF INVERTER DRIVE WITH CLOSE
1 DRIVE SYSTEM
LOOP ENCODER FEEDBACK
2 MACHINE TYPE GEARLESS PMSM
3 MACHINE ROOM POSITION Vendor To Specify
4 EVACUATION DEVICE Vendor To Specify
5 MOTOR RATING Vendor To Specify KW
PERMENENT SYNCHRONOUS MAGNET
6 TYPE OF MOTOR MOTOR
Motor • EFF1 (efficiency class 1) type.
7 ROPING RATIO Vendor To Specify
8 VOLTAGE 415+/- 10 %
9 FREQUENCY 50 +/- 3 %
10 PHASE 3 PHASE, 4WIRE SYSTEM VOLTS
11 MOTOR INSULATION CLASS CLASS F HZ
12 MOTOR PROTECTION CLASS IP 21
13 MAX MOTOR STARTS PER HOUR Vendor To Specify
14 STARTING CURRENT OF MOTOR Vendor To Specify
15 FULL LOAD CURRENT OF MOTOR Vendor To Specify

E POWER SUPPLY FOR LIGHTING


1 VOLTAGE 230.0 VOLTS
2 50 50.0 HZ
3 PHASE 1 PHASE, 3WIRE SYSTEM

F BREAKING SYSTEM
1 TYPE OF OPERATION As per tender specs
2 MAGNETIC BREAK AND AUTO STOP As per tender specs

G LUBRICATION SYSTEM
1 TYPE OF LUBRICATION SYSTEM Vendor To Specify
2 OIL CHANGE REQUIREMENT Vendor To Specify

H CONTROL PANEL
1 CONTROLLER TYPE As per tender specs
2 INVERTER TYPE As per tender specs
3 PHASE FAILER RELAY As per tender specs
4 SPEED GOVERNOR As per tender specs
5 OPERATION TYPE SIMPLEX / DUPLEX / TRIPLEX /GROUP
6 DESTINATION CONTROL SYSTEM OPTIONAL
7 ARTIFICIAL INTELLIGENCE OPTIONAL
8 LOCATION OF PANEL Vendor To Specify
9 PROTECTION CLASS IP 21
10 EMERGENCY SERVICE CONTROL As per tender specs
11 INDEPENDENT CONTROL As per tender specs
12 ATTENDANT CONTROL As per tender specs
13 OUT OF SERVICE As per tender specs
14 ADVANCE DOOR OPENING As per tender specs
15 ANTI NUISANCE As per tender specs
16 SHAFT TEMPERATURE As per tender specs

I SAFETY / SECURITY DEVICE


FULL LENGTH INFRA RED LIGHT CURTIAN TO
1 REQUIRED
CAR DOOR
2 DOOR CLOSE /OPEN ALARM BUTTON REQUIRED
3 OVER VOLTAGE PROTECTION REQUIRED
4 UNDER VOLTAGE PROTECTION REQUIRED
5 PHASE REVERSAL PROTECTION REQUIRED
6 FIRE MAN SWITCH REQUIRED
EMERGENCY LANDING DEVICE WITH
7 REQUIRED
BATTERY (ARD)
NUMBER OF OPERATION OF ARD IN SINGLE
8 Vendor To Specify
CHARGED BATTERY.
9 EMERGENCY STOP SWITCH REQUIRED
CENTRAL ALARM (SHAFT) @ 60DB SOUND
10 REQUIRED
LVL.
CONTROLLER CAPABILITY FOR EMERGENCY
11 SAFE LANDING ON FIRE SIGNAL FROM FIRE REQUIRED
ALARM SYSTEM
12 SEISMIC SENSORS NOT REQUIRED
13 SAFETY EDGE DOOR PROTECTION REQUIRED
EMERGENCY ALARM AT THE GROUND
FLOOR LOBBY AND NOT INSIDE THE LIFT PIT
14 REQUIRED
(FOR IDENTIFICATION OF EMERGENCY
SOONER)

J CONTROL FEATURES
1 OVER LOAD CONTROL & INDICATION REQUIRED
2 FULL LOAD BY PASS REQUIRED
3 AUTOMATIC RETURN TO MAIN FLOOR REQUIRED
4 INTER LOCK SWITCH REQUIRED
BATTERY OPERATED EMERGENCY LIGHT
5 REQUIRED
AND ALARM (15MIN BACKUP)
TECHANICAL DATA SHEET FOR PASSENGER ELEVATOR
SR.
PARTICULARS TENDER SPECS UNITS VENDOR CONFIRMATION
NO.
VISUAL CONFIRMATION OF CALL
6 REQUIRED
REGISTRATION
VVVF DOOR DRIVE WITH CLOSELOOP
7 REQUIRED
ENCODER FEEDBACK
8 DOOR NUDGING OPERATION REQUIRED
9 AUTO DOOR CLOSING TIME CONTROL REQUIRED
10 CAR VENTILLATION (AUTO SHUT OFF) REQUIRED
INTERCOM FROM CAR CABIN TO
CONTROLLER BMS/SECURITY ROOM & 2
EXTRA LEADS.
11 (2 Way Interphone, without any external device in NOT REQUIRED
Car) i.e. COP comprising a press & speak unit
(with battery backup & should support IP based
EPBAX system)
13 BUFFER REQUIRED
14 ATTENDENT SERVICE REQUIRED
15 LOAD WEIGHING DEVICE REQUIRED
FALSE CALL CANCELLING BUTTON
16 REQUIRED
OPERATION
17 CAR LIGHT (AUTO SHUT OFF) REQUIRED

K B.M.S & SECURITY INTERFACE


Modbus on RS 485 [Vendor to provide Mobus
1 INTERFACE TO BMS SYSTEM
Mapping details for all points]
2 LIFT IN NORMAL MODE REQUIRED
3 LIFT IN MAINTENANCE MODE REQUIRED
4 LIFT IN FIRE MODE REQUIRED
5 LIFT IN ALARM BELL STATUS REQUIRED
POTENTIAL FREE CONTACT TO BE
PROVIDED INSIDE LIFT CONTROL.PANEL TO
ACCEPT THE AUTOMATIC SIGNAL FROM
6 REQUIRED
FIRE ALARM SYSTEM DURING EMERGENCY
CONDITIONS [LIFT SHOULD LAND IN
GROUND FLOOR WITH DOOR OPEN]

COMMON BUILDING MANAGEMENT SYSTEM


7 FOR ALL ELEVATORS WITH RS 485 REQUIRED
INTERFACE.

L DIMENSIONAL DETAILS
1 OVER HEAD HEIGHT Vendor To Specify MM
CUT OUT SIZE FOR SMOKE /FIRE
2 Vendor To Specify MMXMM
VENTILATION
DETAILS OF ANY CUTOUTS REQUIRED IN
3 Vendor To Specify MMXMM
M/C ROOM

Note for above calculations in section "s" consider following details as base assumption.
1) 180 Trips per day, 300 days per year.
2) 50% trips UP with NO LOAD, from bottom to top.
3) 50% trips DN with NO LOAD, from top to Bottom.
4) Lift is kept ON for 24 Hrs per day, 365 days a year.