You are on page 1of 7

How to predict mixing time in a mixing tank with ANSYS FLUENT?

 
 
To predict mixing time a steady state solution of the flow field is calculated. After that we switch 
to transient solver and monitor the mass fraction of two tracer species ­ poured at top (tracer­a) 
and bottom (tracer­b) of the tank. The monitor points vary in axial position in the tank. 
 
Basic Setup of steady­state simulation of flow field. 
 
Tank Volume = 164 l 
Impeller Diameter = 0.3 m 
 
Material: Water (rho = 998.2 kg/m3; eta = 0.001003 kg/m­s) 
Impeller Speed: 100 rpm 
Re number: approx. 150k ­ larger than 10k means turbulent flow 
 

 
 
 
● Read steady­state solution in a 3ddp FLUENT session and DO NOT initialize the 
solution. 
 
● Switch to transient solver 
 
● Activate Species Transport at Models > Species > Species Transport  
 
 
● Define a Mixture containing 2 tracer species having the same properties like water. 
 

 
Check the material properties of the mixture. Density should be set to volume­weighted mixing 
law. Viscosity should be set to mass­weighted mixing law. Diffusivity should be set to values 
2​
related to water e.g. 2e­9 m​/s. 
 
● Define point surfaces to monitor mass fraction of tracers at Surface > Point 
point­1 = {0;0.1;0.2} 
point­2 = {0;0.3;0.2} 
 
 

 
 
 
 
 
● Define monitors for tracer mass fraction at points at Solution > Monitors > Surface. You 
can use copy (RMB at a defined monitor) to setup the monitors faster. 
 
 
All points for one tracer are shown in the same window (tracer­a = Window3; tracer­b = 
Window4). 
 
● Switch off flow equations at Solution > Controls > Equations 

 
 
● Define initial conditions for tracers.  
Tracer­a is filled over the complete top level. Tracer­b is filled at a probe near the bottom (Probe 
Position (0,­0.05,0.15); Probe Diameter 0.1)). To initialize the mass­fraction of the tracers we 
have to mark some cells using Adapt > Region. 
 
 
Tracer­a 

 
Tracer­b: 

 
 
The marked elements get initial condition for related tracers using patch (Solution > Solution 
Initialization > Patch). 
 
 

 
 
 
● Start transient simulation. Run 100 time steps using 0.1 stime step size. Finally we get 
these plots to estimate the mixing times for different filling positions. 
 
 
 

 
 
 